Refine your search
2 vulnerabilities found for Terra AC wallbox (MID/ CE) -Terra AC Juno CE by ABB
CVE-2025-5517 (GCVE-0-2025-5517)
Vulnerability from nvd
Published
2025-10-20 18:27
Modified
2025-10-20 18:47
Severity ?
6.1 (Medium) - CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N
6.8 (Medium) - CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:H
6.8 (Medium) - CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-122 - Heap-based Buffer Overflow
Summary
Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (MID/ CE) -Terra AC MID, ABB Terra AC wallbox (MID/ CE) -Terra AC Juno CE, ABB Terra AC wallbox (MID/ CE) -Terra AC PTB, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): through 1.8.32; Terra AC wallbox (UL32A): through 1.8.2; Terra AC wallbox (MID/ CE) -Terra AC MID: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC Juno CE: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC PTB: through 1.8.21; Terra AC wallbox (JP): through 1.8.2.
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ABB | Terra AC wallbox (UL40/80A) |
Version: 0 < |
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-5517",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-20T18:47:11.327089Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-20T18:47:22.917Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Terra AC wallbox (UL40/80A)",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "1.8.32",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Terra AC wallbox (UL32A)",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "1.8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Terra AC wallbox (MID/ CE) -Terra AC MID",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "1.8.32",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Terra AC wallbox (MID/ CE) -Terra AC Juno CE",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "1.8.32",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Terra AC wallbox (MID/ CE) -Terra AC PTB",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "1.8.21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Terra AC wallbox (JP)",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "1.8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "ABB also acknowledges and thanks Itai Shmueli from Saiflow who also responsibly disclosed these vulnerabilities and provided valuable input on product improvements."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (MID/ CE) -Terra AC MID, ABB Terra AC wallbox (MID/ CE) -Terra AC Juno CE, ABB Terra AC wallbox (MID/ CE) -Terra AC PTB, ABB Terra AC wallbox (JP).\u003cp\u003eThis issue affects Terra AC wallbox (UL40/80A): through 1.8.32; Terra AC wallbox (UL32A): through 1.8.2; Terra AC wallbox (MID/ CE) -Terra AC MID: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC Juno CE: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC PTB: through 1.8.21; Terra AC wallbox (JP): through 1.8.2.\u003c/p\u003e"
}
],
"value": "Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (MID/ CE) -Terra AC MID, ABB Terra AC wallbox (MID/ CE) -Terra AC Juno CE, ABB Terra AC wallbox (MID/ CE) -Terra AC PTB, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): through 1.8.32; Terra AC wallbox (UL32A): through 1.8.2; Terra AC wallbox (MID/ CE) -Terra AC MID: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC Juno CE: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC PTB: through 1.8.21; Terra AC wallbox (JP): through 1.8.2."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-20T18:27:32.374Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108471A8948\u0026LanguageCode=en\u0026DocumentPartId=PDF\u0026Action=Launch"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The problem is corrected in the following product versions; apply the following update depending on product variant:\u003cul\u003e\u003cli\u003eTerra AC wallbox (UL40/80A) 1.8.33\u003c/li\u003e\u003cli\u003eTerra AC wallbox (UL32A) 1.8.34\u003c/li\u003e\u003cli\u003eTerra AC MID 1.8.34\u003c/li\u003e\u003cli\u003eTerra AC Juno CE 1.8.34\u003c/li\u003e\u003cli\u003eTerra AC PTB 1.8.33\u003c/li\u003e\u003cli\u003eTerra AC wallbox (JP) 1.8.34\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
}
],
"value": "The problem is corrected in the following product versions; apply the following update depending on product variant: * Terra AC wallbox (UL40/80A) 1.8.33\n * Terra AC wallbox (UL32A) 1.8.34\n * Terra AC MID 1.8.34\n * Terra AC Juno CE 1.8.34\n * Terra AC PTB 1.8.33\n * Terra AC wallbox (JP) 1.8.34"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Heap Memory Corruption Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2025-5517",
"datePublished": "2025-10-20T18:27:32.374Z",
"dateReserved": "2025-06-03T08:51:33.612Z",
"dateUpdated": "2025-10-20T18:47:22.917Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-5517 (GCVE-0-2025-5517)
Vulnerability from cvelistv5
Published
2025-10-20 18:27
Modified
2025-10-20 18:47
Severity ?
6.1 (Medium) - CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N
6.8 (Medium) - CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:H
6.8 (Medium) - CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-122 - Heap-based Buffer Overflow
Summary
Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (MID/ CE) -Terra AC MID, ABB Terra AC wallbox (MID/ CE) -Terra AC Juno CE, ABB Terra AC wallbox (MID/ CE) -Terra AC PTB, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): through 1.8.32; Terra AC wallbox (UL32A): through 1.8.2; Terra AC wallbox (MID/ CE) -Terra AC MID: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC Juno CE: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC PTB: through 1.8.21; Terra AC wallbox (JP): through 1.8.2.
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ABB | Terra AC wallbox (UL40/80A) |
Version: 0 < |
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-5517",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-20T18:47:11.327089Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-20T18:47:22.917Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Terra AC wallbox (UL40/80A)",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "1.8.32",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Terra AC wallbox (UL32A)",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "1.8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Terra AC wallbox (MID/ CE) -Terra AC MID",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "1.8.32",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Terra AC wallbox (MID/ CE) -Terra AC Juno CE",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "1.8.32",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Terra AC wallbox (MID/ CE) -Terra AC PTB",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "1.8.21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Terra AC wallbox (JP)",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "1.8.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "ABB also acknowledges and thanks Itai Shmueli from Saiflow who also responsibly disclosed these vulnerabilities and provided valuable input on product improvements."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (MID/ CE) -Terra AC MID, ABB Terra AC wallbox (MID/ CE) -Terra AC Juno CE, ABB Terra AC wallbox (MID/ CE) -Terra AC PTB, ABB Terra AC wallbox (JP).\u003cp\u003eThis issue affects Terra AC wallbox (UL40/80A): through 1.8.32; Terra AC wallbox (UL32A): through 1.8.2; Terra AC wallbox (MID/ CE) -Terra AC MID: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC Juno CE: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC PTB: through 1.8.21; Terra AC wallbox (JP): through 1.8.2.\u003c/p\u003e"
}
],
"value": "Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (MID/ CE) -Terra AC MID, ABB Terra AC wallbox (MID/ CE) -Terra AC Juno CE, ABB Terra AC wallbox (MID/ CE) -Terra AC PTB, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): through 1.8.32; Terra AC wallbox (UL32A): through 1.8.2; Terra AC wallbox (MID/ CE) -Terra AC MID: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC Juno CE: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC PTB: through 1.8.21; Terra AC wallbox (JP): through 1.8.2."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-20T18:27:32.374Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108471A8948\u0026LanguageCode=en\u0026DocumentPartId=PDF\u0026Action=Launch"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The problem is corrected in the following product versions; apply the following update depending on product variant:\u003cul\u003e\u003cli\u003eTerra AC wallbox (UL40/80A) 1.8.33\u003c/li\u003e\u003cli\u003eTerra AC wallbox (UL32A) 1.8.34\u003c/li\u003e\u003cli\u003eTerra AC MID 1.8.34\u003c/li\u003e\u003cli\u003eTerra AC Juno CE 1.8.34\u003c/li\u003e\u003cli\u003eTerra AC PTB 1.8.33\u003c/li\u003e\u003cli\u003eTerra AC wallbox (JP) 1.8.34\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
}
],
"value": "The problem is corrected in the following product versions; apply the following update depending on product variant: * Terra AC wallbox (UL40/80A) 1.8.33\n * Terra AC wallbox (UL32A) 1.8.34\n * Terra AC MID 1.8.34\n * Terra AC Juno CE 1.8.34\n * Terra AC PTB 1.8.33\n * Terra AC wallbox (JP) 1.8.34"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Heap Memory Corruption Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2025-5517",
"datePublished": "2025-10-20T18:27:32.374Z",
"dateReserved": "2025-06-03T08:51:33.612Z",
"dateUpdated": "2025-10-20T18:47:22.917Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}