All the vulnerabilites related to Siemens - Teamcenter Visualization V2406
cve-2024-37996
Vulnerability from cvelistv5
Published
2024-07-09 12:05
Modified
2024-10-08 08:40
Severity ?
3.3 (Low) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L
4.8 (Medium) - CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N
4.8 (Medium) - CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N
EPSS score ?
Summary
A vulnerability has been identified in JT Open (All versions < V11.5), JT2Go (All versions < V2406.0003), PLM XML SDK (All versions < V7.1.0.014), Teamcenter Visualization V14.2 (All versions < V14.2.0.13), Teamcenter Visualization V14.3 (All versions < V14.3.0.11), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0003). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted XML files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | JT Open |
Version: 0 < V11.5 |
||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-37996", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-07-15T18:31:15.685735Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-15T18:31:24.493Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T04:04:24.762Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-824889.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "JT Open", "vendor": "Siemens", "versions": [ { "lessThan": "V11.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "JT2Go", "vendor": "Siemens", "versions": [ { "lessThan": "V2406.0003", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "PLM XML SDK", "vendor": "Siemens", "versions": [ { "lessThan": "V7.1.0.014", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.2", "vendor": "Siemens", "versions": [ { "lessThan": "V14.2.0.13", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.3", "vendor": "Siemens", "versions": [ { "lessThan": "V14.3.0.11", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2312", "vendor": "Siemens", "versions": [ { "lessThan": "V2312.0008", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2406", "vendor": "Siemens", "versions": [ { "lessThan": "V2406.0003", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in JT Open (All versions \u003c V11.5), JT2Go (All versions \u003c V2406.0003), PLM XML SDK (All versions \u003c V7.1.0.014), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.13), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.11), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Teamcenter Visualization V2406 (All versions \u003c V2406.0003). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted XML files. An attacker could leverage this vulnerability to crash the application causing denial of service condition." } ], "metrics": [ { "cvssV3_1": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 4.8, "baseSeverity": "MEDIUM", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-476", "description": "CWE-476: NULL Pointer Dereference", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-10-08T08:40:13.781Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-824889.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-959281.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-37996", "datePublished": "2024-07-09T12:05:04.781Z", "dateReserved": "2024-06-11T08:32:52.184Z", "dateUpdated": "2024-10-08T08:40:13.781Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-52565
Vulnerability from cvelistv5
Published
2024-11-18 15:39
Modified
2024-12-10 13:53
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
EPSS score ?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file.
This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24231)
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Teamcenter Visualization V14.2 |
Version: 0 < V14.2.0.14 |
||||||||||||||||||||
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:siemens:tecnomatix_plant_simulation:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "tecnomatix_plant_simulation", "vendor": "siemens", "versions": [ { "lessThan": "V2302.0018", "status": "affected", "version": "0", "versionType": "custom" }, { "lessThan": "V2404.0007", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-52565", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-18T20:14:21.266990Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-18T20:15:13.258Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.2", "vendor": "Siemens", "versions": [ { "lessThan": "V14.2.0.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.3", "vendor": "Siemens", "versions": [ { "lessThan": "V14.3.0.12", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2312", "vendor": "Siemens", "versions": [ { "lessThan": "V2312.0008", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2406", "vendor": "Siemens", "versions": [ { "lessThan": "V2406.0005", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2302", "vendor": "Siemens", "versions": [ { "lessThan": "V2302.0018", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2404", "vendor": "Siemens", "versions": [ { "lessThan": "V2404.0007", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.14), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.12), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Teamcenter Visualization V2406 (All versions \u003c V2406.0005), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0018), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0007). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file.\r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24231)" } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787: Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-10T13:53:58.951Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-824503.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-52565", "datePublished": "2024-11-18T15:39:23.758Z", "dateReserved": "2024-11-14T12:25:53.335Z", "dateUpdated": "2024-12-10T13:53:58.951Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-52570
Vulnerability from cvelistv5
Published
2024-11-18 15:39
Modified
2024-12-10 13:54
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
EPSS score ?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file.
This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24365)
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Teamcenter Visualization V14.2 |
Version: 0 < V14.2.0.14 |
||||||||||||||||||||
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:siemens:tecnomatix_plant_simulation:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "tecnomatix_plant_simulation", "vendor": "siemens", "versions": [ { "lessThan": "V2302.0018", "status": "affected", "version": "0", "versionType": "custom" }, { "lessThan": "V2404.0007", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-52570", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-18T18:54:23.506856Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-18T18:55:49.764Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.2", "vendor": "Siemens", "versions": [ { "lessThan": "V14.2.0.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.3", "vendor": "Siemens", "versions": [ { "lessThan": "V14.3.0.12", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2312", "vendor": "Siemens", "versions": [ { "lessThan": "V2312.0008", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2406", "vendor": "Siemens", "versions": [ { "lessThan": "V2406.0005", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2302", "vendor": "Siemens", "versions": [ { "lessThan": "V2302.0018", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2404", "vendor": "Siemens", "versions": [ { "lessThan": "V2404.0007", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.14), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.12), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Teamcenter Visualization V2406 (All versions \u003c V2406.0005), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0018), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0007). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file.\r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24365)" } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787: Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-10T13:54:05.476Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-824503.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-52570", "datePublished": "2024-11-18T15:39:32.522Z", "dateReserved": "2024-11-14T12:25:53.335Z", "dateUpdated": "2024-12-10T13:54:05.476Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-52571
Vulnerability from cvelistv5
Published
2024-11-18 15:39
Modified
2024-12-10 13:54
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
EPSS score ?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file.
This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24485)
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Teamcenter Visualization V14.2 |
Version: 0 < V14.2.0.14 |
||||||||||||||||||||
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "tecnomatix_plant_simulation", "vendor": "siemens", "versions": [ { "lessThan": "2302.0018", "status": "affected", "version": "0", "versionType": "custom" }, { "lessThan": "2404.0007", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-52571", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-18T16:33:26.041394Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-18T16:34:15.757Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.2", "vendor": "Siemens", "versions": [ { "lessThan": "V14.2.0.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.3", "vendor": "Siemens", "versions": [ { "lessThan": "V14.3.0.12", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2312", "vendor": "Siemens", "versions": [ { "lessThan": "V2312.0008", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2406", "vendor": "Siemens", "versions": [ { "lessThan": "V2406.0005", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2302", "vendor": "Siemens", "versions": [ { "lessThan": "V2302.0018", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2404", "vendor": "Siemens", "versions": [ { "lessThan": "V2404.0007", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.14), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.12), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Teamcenter Visualization V2406 (All versions \u003c V2406.0005), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0018), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0007). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file.\r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24485)" } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787: Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-10T13:54:06.770Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-824503.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-52571", "datePublished": "2024-11-18T15:39:34.061Z", "dateReserved": "2024-11-14T12:25:53.336Z", "dateUpdated": "2024-12-10T13:54:06.770Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-52567
Vulnerability from cvelistv5
Published
2024-11-18 15:39
Modified
2024-12-10 13:54
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
EPSS score ?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.
This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24237)
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Teamcenter Visualization V14.2 |
Version: 0 < V14.2.0.14 |
||||||||||||||||||||
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:siemens:tecnomatix_plant_simulation:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "tecnomatix_plant_simulation", "vendor": "siemens", "versions": [ { "lessThan": "V2302.0018", "status": "affected", "version": "0", "versionType": "custom" }, { "lessThan": "V2404.0007", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-52567", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-18T19:02:36.401253Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-18T19:04:07.097Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.2", "vendor": "Siemens", "versions": [ { "lessThan": "V14.2.0.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.3", "vendor": "Siemens", "versions": [ { "lessThan": "V14.3.0.12", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2312", "vendor": "Siemens", "versions": [ { "lessThan": "V2312.0008", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2406", "vendor": "Siemens", "versions": [ { "lessThan": "V2406.0005", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2302", "vendor": "Siemens", "versions": [ { "lessThan": "V2302.0018", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2404", "vendor": "Siemens", "versions": [ { "lessThan": "V2404.0007", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.14), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.12), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Teamcenter Visualization V2406 (All versions \u003c V2406.0005), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0018), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0007). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24237)" } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-10T13:54:01.572Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-824503.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-52567", "datePublished": "2024-11-18T15:39:26.910Z", "dateReserved": "2024-11-14T12:25:53.335Z", "dateUpdated": "2024-12-10T13:54:01.572Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-52566
Vulnerability from cvelistv5
Published
2024-11-18 15:39
Modified
2024-12-10 13:54
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
EPSS score ?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file.
This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24233)
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Teamcenter Visualization V14.2 |
Version: 0 < V14.2.0.14 |
||||||||||||||||||||
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:siemens:tecnomatix_plant_simulation:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "tecnomatix_plant_simulation", "vendor": "siemens", "versions": [ { "lessThan": "V2302.0018", "status": "affected", "version": "0", "versionType": "custom" }, { "lessThan": "V2404.0007", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-52566", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-18T19:50:45.809688Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-18T19:51:41.469Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.2", "vendor": "Siemens", "versions": [ { "lessThan": "V14.2.0.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.3", "vendor": "Siemens", "versions": [ { "lessThan": "V14.3.0.12", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2312", "vendor": "Siemens", "versions": [ { "lessThan": "V2312.0008", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2406", "vendor": "Siemens", "versions": [ { "lessThan": "V2406.0005", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2302", "vendor": "Siemens", "versions": [ { "lessThan": "V2302.0018", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2404", "vendor": "Siemens", "versions": [ { "lessThan": "V2404.0007", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.14), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.12), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Teamcenter Visualization V2406 (All versions \u003c V2406.0005), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0018), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0007). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file.\r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24233)" } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787: Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-10T13:54:00.271Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-824503.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-52566", "datePublished": "2024-11-18T15:39:25.382Z", "dateReserved": "2024-11-14T12:25:53.335Z", "dateUpdated": "2024-12-10T13:54:00.271Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-52572
Vulnerability from cvelistv5
Published
2024-11-18 15:39
Modified
2024-12-10 13:54
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
EPSS score ?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain a stack based overflow vulnerability while parsing specially crafted WRL files.
This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24486)
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Teamcenter Visualization V14.2 |
Version: 0 < V14.2.0.14 |
||||||||||||||||||||
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "tecnomatix_plant_simulation", "vendor": "siemens", "versions": [ { "lessThan": "2302.0018", "status": "affected", "version": "0", "versionType": "custom" }, { "lessThan": "2404.0007", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "tecnomatix_plant_simulation", "vendor": "siemens", "versions": [ { "lessThan": "2302.0018", "status": "affected", "version": "0", "versionType": "custom" }, { "lessThan": "2404.0007", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-52572", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-18T17:58:30.237542Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-18T18:08:38.319Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.2", "vendor": "Siemens", "versions": [ { "lessThan": "V14.2.0.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.3", "vendor": "Siemens", "versions": [ { "lessThan": "V14.3.0.12", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2312", "vendor": "Siemens", "versions": [ { "lessThan": "V2312.0008", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2406", "vendor": "Siemens", "versions": [ { "lessThan": "V2406.0005", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2302", "vendor": "Siemens", "versions": [ { "lessThan": "V2302.0018", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2404", "vendor": "Siemens", "versions": [ { "lessThan": "V2404.0007", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.14), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.12), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Teamcenter Visualization V2406 (All versions \u003c V2406.0005), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0018), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0007). The affected applications contain a stack based overflow vulnerability while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24486)" } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121: Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-10T13:54:08.165Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-824503.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-52572", "datePublished": "2024-11-18T15:39:35.577Z", "dateReserved": "2024-11-14T12:25:53.336Z", "dateUpdated": "2024-12-10T13:54:08.165Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-52573
Vulnerability from cvelistv5
Published
2024-11-18 15:39
Modified
2024-12-10 13:54
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
EPSS score ?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file.
This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24521)
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Teamcenter Visualization V14.2 |
Version: 0 < V14.2.0.14 |
||||||||||||||||||||
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "tecnomatix_plant_simulation", "vendor": "siemens", "versions": [ { "lessThan": "2302.0018", "status": "affected", "version": "0", "versionType": "custom" }, { "lessThan": "2404.0007", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "tecnomatix_plant_simulation", "vendor": "siemens", "versions": [ { "lessThan": "2302.0018", "status": "affected", "version": "0", "versionType": "custom" }, { "lessThan": "2404.0007", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-52573", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-18T17:58:35.292347Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-18T18:08:38.439Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.2", "vendor": "Siemens", "versions": [ { "lessThan": "V14.2.0.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.3", "vendor": "Siemens", "versions": [ { "lessThan": "V14.3.0.12", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2312", "vendor": "Siemens", "versions": [ { "lessThan": "V2312.0008", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2406", "vendor": "Siemens", "versions": [ { "lessThan": "V2406.0005", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2302", "vendor": "Siemens", "versions": [ { "lessThan": "V2302.0018", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2404", "vendor": "Siemens", "versions": [ { "lessThan": "V2404.0007", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.14), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.12), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Teamcenter Visualization V2406 (All versions \u003c V2406.0005), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0018), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0007). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file.\r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24521)" } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787: Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-10T13:54:09.478Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-824503.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-52573", "datePublished": "2024-11-18T15:39:37.042Z", "dateReserved": "2024-11-14T12:25:53.336Z", "dateUpdated": "2024-12-10T13:54:09.478Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-37997
Vulnerability from cvelistv5
Published
2024-07-09 12:05
Modified
2024-10-08 08:40
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
EPSS score ?
Summary
A vulnerability has been identified in JT Open (All versions < V11.5), JT2Go (All versions < V2406.0003), PLM XML SDK (All versions < V7.1.0.014), Teamcenter Visualization V14.2 (All versions < V14.2.0.13), Teamcenter Visualization V14.3 (All versions < V14.3.0.11), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0003). The affected applications contain a stack based overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | JT Open |
Version: 0 < V11.5 |
||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:siemens:jt_open:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "jt_open", "vendor": "siemens", "versions": [ { "lessThan": "V11.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:plm_xml_sdk:v7.1.0.0014:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "plm_xml_sdk", "vendor": "siemens", "versions": [ { "status": "affected", "version": "V7.1.0.014" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-37997", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-07-09T13:19:33.793225Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-09T13:25:16.197Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T04:04:24.591Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-824889.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "JT Open", "vendor": "Siemens", "versions": [ { "lessThan": "V11.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "JT2Go", "vendor": "Siemens", "versions": [ { "lessThan": "V2406.0003", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "PLM XML SDK", "vendor": "Siemens", "versions": [ { "lessThan": "V7.1.0.014", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.2", "vendor": "Siemens", "versions": [ { "lessThan": "V14.2.0.13", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.3", "vendor": "Siemens", "versions": [ { "lessThan": "V14.3.0.11", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2312", "vendor": "Siemens", "versions": [ { "lessThan": "V2312.0008", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2406", "vendor": "Siemens", "versions": [ { "lessThan": "V2406.0003", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in JT Open (All versions \u003c V11.5), JT2Go (All versions \u003c V2406.0003), PLM XML SDK (All versions \u003c V7.1.0.014), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.13), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.11), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Teamcenter Visualization V2406 (All versions \u003c V2406.0003). The affected applications contain a stack based overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121: Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-10-08T08:40:15.076Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-824889.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-959281.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-37997", "datePublished": "2024-07-09T12:05:06.114Z", "dateReserved": "2024-06-11T08:32:52.184Z", "dateUpdated": "2024-10-08T08:40:15.076Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-52574
Vulnerability from cvelistv5
Published
2024-11-18 15:39
Modified
2024-12-10 13:54
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
EPSS score ?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.
This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24543)
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Teamcenter Visualization V14.2 |
Version: 0 < V14.2.0.14 |
||||||||||||||||||||
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "tecnomatix_plant_simulation", "vendor": "siemens", "versions": [ { "lessThan": "2302.0018", "status": "affected", "version": "0", "versionType": "custom" }, { "lessThan": "2404.0007", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "tecnomatix_plant_simulation", "vendor": "siemens", "versions": [ { "lessThan": "2302.0018", "status": "affected", "version": "0", "versionType": "custom" }, { "lessThan": "2404.0007", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-52574", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-18T17:58:40.018851Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-18T18:08:38.549Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.2", "vendor": "Siemens", "versions": [ { "lessThan": "V14.2.0.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.3", "vendor": "Siemens", "versions": [ { "lessThan": "V14.3.0.12", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2312", "vendor": "Siemens", "versions": [ { "lessThan": "V2312.0008", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2406", "vendor": "Siemens", "versions": [ { "lessThan": "V2406.0005", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2302", "vendor": "Siemens", "versions": [ { "lessThan": "V2302.0018", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2404", "vendor": "Siemens", "versions": [ { "lessThan": "V2404.0007", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.14), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.12), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Teamcenter Visualization V2406 (All versions \u003c V2406.0005), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0018), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0007). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24543)" } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-10T13:54:10.791Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-824503.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-52574", "datePublished": "2024-11-18T15:39:38.552Z", "dateReserved": "2024-11-14T12:25:53.336Z", "dateUpdated": "2024-12-10T13:54:10.791Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-52568
Vulnerability from cvelistv5
Published
2024-11-18 15:39
Modified
2024-12-10 13:54
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
EPSS score ?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files.
An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-24244)
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Teamcenter Visualization V14.2 |
Version: 0 < V14.2.0.14 |
||||||||||||||||||||
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:siemens:tecnomatix_plant_simulation:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "tecnomatix_plant_simulation", "vendor": "siemens", "versions": [ { "lessThan": "V2302.0018", "status": "affected", "version": "0", "versionType": "custom" }, { "lessThan": "V2404.0007", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-52568", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-18T19:00:13.859137Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-18T19:01:12.420Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.2", "vendor": "Siemens", "versions": [ { "lessThan": "V14.2.0.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.3", "vendor": "Siemens", "versions": [ { "lessThan": "V14.3.0.12", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2312", "vendor": "Siemens", "versions": [ { "lessThan": "V2312.0008", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2406", "vendor": "Siemens", "versions": [ { "lessThan": "V2406.0005", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2302", "vendor": "Siemens", "versions": [ { "lessThan": "V2302.0018", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2404", "vendor": "Siemens", "versions": [ { "lessThan": "V2404.0007", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.14), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.12), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Teamcenter Visualization V2406 (All versions \u003c V2406.0005), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0018), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0007). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files.\r\nAn attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-24244)" } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-416", "description": "CWE-416: Use After Free", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-10T13:54:02.868Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-824503.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-52568", "datePublished": "2024-11-18T15:39:28.462Z", "dateReserved": "2024-11-14T12:25:53.335Z", "dateUpdated": "2024-12-10T13:54:02.868Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-52569
Vulnerability from cvelistv5
Published
2024-11-18 15:39
Modified
2024-12-10 13:54
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
EPSS score ?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file.
This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24260)
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Teamcenter Visualization V14.2 |
Version: 0 < V14.2.0.14 |
||||||||||||||||||||
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:siemens:tecnomatix_plant_simulation:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "tecnomatix_plant_simulation", "vendor": "siemens", "versions": [ { "lessThan": "V2302.0018", "status": "affected", "version": "0", "versionType": "custom" }, { "lessThan": "V2404.0007", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-52569", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-18T18:56:43.464014Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-18T18:57:44.608Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.2", "vendor": "Siemens", "versions": [ { "lessThan": "V14.2.0.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.3", "vendor": "Siemens", "versions": [ { "lessThan": "V14.3.0.12", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2312", "vendor": "Siemens", "versions": [ { "lessThan": "V2312.0008", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2406", "vendor": "Siemens", "versions": [ { "lessThan": "V2406.0005", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2302", "vendor": "Siemens", "versions": [ { "lessThan": "V2302.0018", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2404", "vendor": "Siemens", "versions": [ { "lessThan": "V2404.0007", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.14), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.12), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Teamcenter Visualization V2406 (All versions \u003c V2406.0005), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0018), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0007). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file.\r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24260)" } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787: Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-10T13:54:04.159Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-824503.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-52569", "datePublished": "2024-11-18T15:39:29.963Z", "dateReserved": "2024-11-14T12:25:53.335Z", "dateUpdated": "2024-12-10T13:54:04.159Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }