Vulnerabilites related to Smarttek Informatics - Smart Doctor
CVE-2024-7016 (GCVE-0-2024-7016)
Vulnerability from cvelistv5
Published
2024-11-21 12:25
Modified
2025-09-16 13:46
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Summary
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Smarttek Informatics Smart Doctor's allows Stored XSS required admin privileges.This issue affects Smart Doctor: through 21.11.2024. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7016",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-21T14:37:53.795314Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-16T13:46:13.608Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Smart Doctor",
          "vendor": "Smarttek Informatics",
          "versions": [
            {
              "lessThanOrEqual": "21.11.2024",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Selman KONAKCI"
        },
        {
          "lang": "en",
          "type": "sponsor",
          "value": "Turkish Technology Inc."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Smarttek Informatics Smart Doctor\u0027s allows Stored XSS required admin privileges.\u003cp\u003eThis issue affects Smart Doctor: through 21.11.2024.\u003c/p\u003e\u003cp\u003e\nNOTE: The vendor was contacted early about this disclosure but did not respond in any way.\n\n\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027) vulnerability in Smarttek Informatics Smart Doctor\u0027s allows Stored XSS required admin privileges.This issue affects Smart Doctor: through 21.11.2024.\n\n\nNOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-592",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-592 Stored XSS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-12T06:50:27.785Z",
        "orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
        "shortName": "TR-CERT"
      },
      "references": [
        {
          "url": "https://www.usom.gov.tr/bildirim/tr-24-1865"
        }
      ],
      "source": {
        "advisory": "TR-24-1865",
        "defect": [
          "TR-24-1865"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "Stored XSS in Smarttek Informatics\u0027 Smart Doctor",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
    "assignerShortName": "TR-CERT",
    "cveId": "CVE-2024-7016",
    "datePublished": "2024-11-21T12:25:17.272Z",
    "dateReserved": "2024-07-23T13:08:26.357Z",
    "dateUpdated": "2025-09-16T13:46:13.608Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}