All the vulnerabilites related to Siemens - SIMATIC STEP 7 V5
cve-2020-7580
Vulnerability from cvelistv5
Published
2020-06-10 00:00
Modified
2024-08-04 09:33
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC Automation Tool |
Version: All versions < V4 SP2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T09:33:19.492Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf" }, { "tags": [ "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC Automation Tool", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4 SP2" } ] }, { "product": "SIMATIC NET PC Software V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 14" } ] }, { "product": "SIMATIC NET PC Software V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC NET PC Software V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Upd3" } ] }, { "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0 SP1" } ] }, { "product": "SIMATIC ProSave", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V17" } ] }, { "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V21.8" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V13", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13 SP2 Update 4" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 10" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 5" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 2" } ] }, { "product": "SIMATIC STEP 7 V5", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.6 SP2 HF3" } ] }, { "product": "SIMATIC WinCC OA V3.16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.16 P018" } ] }, { "product": "SIMATIC WinCC OA V3.17", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.17 P003" } ] }, { "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 2" } ] }, { "product": "SIMATIC WinCC Runtime Professional V13", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13 SP2 Update 4" } ] }, { "product": "SIMATIC WinCC Runtime Professional V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 10" } ] }, { "product": "SIMATIC WinCC Runtime Professional V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 5" } ] }, { "product": "SIMATIC WinCC Runtime Professional V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 2" } ] }, { "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.4 SP1 Update 14" } ] }, { "product": "SIMATIC WinCC V7.5", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.5 SP1 Update 3" } ] }, { "product": "SINAMICS STARTER", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.4 HF2" } ] }, { "product": "SINAMICS Startdrive", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V16 Update 3" } ] }, { "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0 SP2" } ] }, { "product": "SINEMA Server", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP3" } ] }, { "product": "SINUMERIK ONE virtual", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V6.14" } ] }, { "product": "SINUMERIK Operate", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V6.14" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC Automation Tool (All versions \u003c V4 SP2), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Upd3), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC ProSave (All versions \u003c V17), SIMATIC S7-1500 Software Controller (All versions \u003c V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMATIC STEP 7 V5 (All versions \u003c V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions \u003c V3.16 P018), SIMATIC WinCC OA V3.17 (All versions \u003c V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions \u003c V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 3), SINAMICS STARTER (All Versions \u003c V5.4 HF2), SINAMICS Startdrive (All Versions \u003c V16 Update 3), SINEC NMS (All versions \u003c V1.0 SP2), SINEMA Server (All versions \u003c V14 SP3), SINUMERIK ONE virtual (All Versions \u003c V6.14), SINUMERIK Operate (All Versions \u003c V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-428", "description": "CWE-428: Unquoted Search Path or Element", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-13T00:00:00", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf" }, { "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-7580", "datePublished": "2020-06-10T00:00:00", "dateReserved": "2020-01-21T00:00:00", "dateUpdated": "2024-08-04T09:33:19.492Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-46280
Vulnerability from cvelistv5
Published
2024-05-14 10:01
Modified
2024-12-10 13:53
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions < V5.0 SP2), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions < V16 Update 8), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions < V18 SP1), SIMATIC NET PC Software V19 (All versions < V19 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PDM V9.2 (All versions < V9.2 SP2 Upd3), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 Upd3), SIMATIC S7-PCT (All versions < V3.5 SP3 Update 6), SIMATIC STEP 7 V5 (All versions < V5.7 SP3), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions < V3.18 P025), SIMATIC WinCC OA V3.19 (All versions < V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5), SINAMICS Startdrive (All versions < V19 SP1), SINEC NMS (All versions < V3.0), SINEC NMS (All versions < V3.0 SP1), SINUMERIK ONE virtual (All versions < V6.23), SINUMERIK PLC Programming Tool (All versions < V3.3.12), TIA Portal Cloud Connector (All versions < V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 2). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel.
References
Impacted products
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2023-46280", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-05-29T14:20:28.448026Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:22:08.819Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T20:37:40.324Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-962515.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Security Configuration Tool (SCT)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Automation Tool", "vendor": "Siemens", "versions": [ { "lessThan": "V5.0 SP2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC BATCH V9.1", "vendor": "Siemens", "versions": [ { "lessThan": "V9.1 SP2 Upd5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V16", "vendor": "Siemens", "versions": [ { "lessThan": "V16 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V17", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V19", "vendor": "Siemens", "versions": [ { "lessThan": "V19 Update 2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V9.1", "vendor": "Siemens", "versions": [ { "lessThan": "V9.1 SP2 UC05", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PDM V9.2", "vendor": "Siemens", "versions": [ { "lessThan": "V9.2 SP2 Upd3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Route Control V9.1", "vendor": "Siemens", "versions": [ { "lessThan": "V9.1 SP2 Upd3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-PCT", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5 SP3 Update 6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC STEP 7 V5", "vendor": "Siemens", "versions": [ { "lessThan": "V5.7 SP3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC OA V3.17", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC OA V3.18", "vendor": "Siemens", "versions": [ { "lessThan": "V3.18 P025", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC OA V3.19", "vendor": "Siemens", "versions": [ { "lessThan": "V3.19 P010", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V16", "vendor": "Siemens", "versions": [ { "lessThan": "V16 Update 6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V19", "vendor": "Siemens", "versions": [ { "lessThan": "V19 Update 2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.5", "vendor": "Siemens", "versions": [ { "lessThan": "V7.5 SP2 Update 17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V8.0", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0 Update 5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS Startdrive", "vendor": "Siemens", "versions": [ { "lessThan": "V19 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK ONE virtual", "vendor": "Siemens", "versions": [ { "lessThan": "V6.23", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK PLC Programming Tool", "vendor": "Siemens", "versions": [ { "lessThan": "V3.3.12", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "TIA Portal Cloud Connector", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V15.1", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V19", "vendor": "Siemens", "versions": [ { "lessThan": "V19 Update 2", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions \u003c V5.0 SP2), SIMATIC BATCH V9.1 (All versions \u003c V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions \u003c V16 Update 8), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions \u003c V18 SP1), SIMATIC NET PC Software V19 (All versions \u003c V19 Update 2), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC PDM V9.2 (All versions \u003c V9.2 SP2 Upd3), SIMATIC Route Control V9.1 (All versions \u003c V9.1 SP2 Upd3), SIMATIC S7-PCT (All versions \u003c V3.5 SP3 Update 6), SIMATIC STEP 7 V5 (All versions \u003c V5.7 SP3), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions \u003c V3.18 P025), SIMATIC WinCC OA V3.19 (All versions \u003c V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions \u003c V17 Update 8), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions \u003c V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 5), SINAMICS Startdrive (All versions \u003c V19 SP1), SINEC NMS (All versions \u003c V3.0), SINEC NMS (All versions \u003c V3.0 SP1), SINUMERIK ONE virtual (All versions \u003c V6.23), SINUMERIK PLC Programming Tool (All versions \u003c V3.3.12), TIA Portal Cloud Connector (All versions \u003c V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions \u003c V19 Update 2). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 8.2, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-10T13:53:28.579Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-962515.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-784301.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-331112.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-46280", "datePublished": "2024-05-14T10:01:52.069Z", "dateReserved": "2023-10-20T08:02:52.794Z", "dateUpdated": "2024-12-10T13:53:28.579Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-25910
Vulnerability from cvelistv5
Published
2023-06-13 08:17
Modified
2024-08-02 11:32
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC PCS 7 (All versions < V9.1 SP2 UC04), SIMATIC S7-PM (All versions < V5.7 SP1 HF1), SIMATIC S7-PM (All versions < V5.7 SP2 HF1), SIMATIC STEP 7 V5 (All versions < V5.7). The affected product contains a database management system that could allow remote users with low privileges to use embedded functions of the database (local or in a network share) that have impact on the server.
An attacker with network access to the server network could leverage these embedded functions to run code with elevated privileges in the database management system's server.
References
Impacted products
Vendor | Product | Version | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC PCS 7 |
Version: 0 < V9.1 SP2 UC04 |
||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:32:12.730Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-968170.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-968170.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC PCS 7", "vendor": "Siemens", "versions": [ { "lessThan": "V9.1 SP2 UC04", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-PM", "vendor": "Siemens", "versions": [ { "lessThan": "V5.7 SP1 HF1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-PM", "vendor": "Siemens", "versions": [ { "lessThan": "V5.7 SP2 HF1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC STEP 7 V5", "vendor": "Siemens", "versions": [ { "lessThan": "V5.7", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC PCS 7 (All versions \u003c V9.1 SP2 UC04), SIMATIC S7-PM (All versions \u003c V5.7 SP1 HF1), SIMATIC S7-PM (All versions \u003c V5.7 SP2 HF1), SIMATIC STEP 7 V5 (All versions \u003c V5.7). The affected product contains a database management system that could allow remote users with low privileges to use embedded functions of the database (local or in a network share) that have impact on the server.\r\n\r\nAn attacker with network access to the server network could leverage these embedded functions to run code with elevated privileges in the database management system\u0027s server." } ], "metrics": [ { "cvssV3_1": { "baseScore": 10, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-94", "description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-15T07:23:34.211Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-968170.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-968170.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-25910", "datePublished": "2023-06-13T08:17:04.612Z", "dateReserved": "2023-02-16T11:12:33.500Z", "dateUpdated": "2024-08-02T11:32:12.730Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }