All the vulnerabilites related to Siemens - SCALANCE XR552-12M
cve-2022-36325
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T10:00:04.293Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) EU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) NAM", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M804PB", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router (Annex A)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router (Annex B)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router (Annex A)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router (Annex B)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M826-2 SHDSL-Router", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3 (EVDO)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3 (ROK)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (NAM)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM853-1 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (RoW)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC622-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC626-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC632-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC636-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC642-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC646-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2 EEC M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2IA M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W721-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W721-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45 (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W738-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W738-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W761-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W761-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45 (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12 EEC (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2IA RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2IA RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM763-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 (US)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 EEC (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 EEC (US)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM763-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM763-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM766-1 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM766-1 (US)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (SC, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3LD (SC, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3LD (SC, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB208 (E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB208 (PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (SC, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (SC, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (ST, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3LD (SC, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3LD (SC, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB216 (E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB216 (PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2 (SC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2 (ST/BFOC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE EEC (54 V DC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G (EIP DEF.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G (EIP def.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-3G PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-3G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204 DNA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA DNA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-8C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-8C (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM416-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM416-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208 (Ethernet/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208PoE EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216 (Ethernet/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216POE EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324WG (24 x FE, AC 230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324WG (24 X FE, DC 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR326-2C PoE WG", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR326-2C PoE WG (without UL)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 1x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 24V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 2x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 1x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 24V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 2x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (2HR2)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC206-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] } ], "descriptions": [ { "lang": "en", "value": "Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.8, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-80", "description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-10-10T10:21:04.880Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-36325", "datePublished": "2022-08-10T11:18:45", "dateReserved": "2022-07-20T00:00:00", "dateUpdated": "2024-08-03T10:00:04.293Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-46142
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | RUGGEDCOM RM1224 LTE(4G) EU |
Version: All versions < V7.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:24:03.321Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) EU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) NAM", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M804PB", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router (Annex A)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router (Annex B)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router (Annex A)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router (Annex B)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M826-2 SHDSL-Router", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3 (EVDO)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3 (ROK)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (NAM)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM853-1 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (RoW)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC622-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC622-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC626-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC626-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC632-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC632-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC636-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC636-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC642-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC642-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC646-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC646-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.3 \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2 EEC M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2IA M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W721-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W721-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45 (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W738-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W738-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W761-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W761-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45 (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12 EEC (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2IA RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2IA RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM763-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 (US)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 EEC (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 EEC (US)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM763-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM763-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM766-1 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM766-1 (US)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (SC, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3LD (SC, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3LD (SC, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB208 (E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB208 (PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (SC, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (SC, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (ST, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3LD (SC, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3LD (SC, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB216 (E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB216 (PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2 (SC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2 (ST/BFOC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE EEC (54 V DC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G (EIP DEF.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G (EIP def.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-3G PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-3G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204 DNA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA DNA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-8C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-8C (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM416-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM416-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208 (Ethernet/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208PoE EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216 (Ethernet/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216POE EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324WG (24 x FE, AC 230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324WG (24 X FE, DC 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR326-2C PoE WG", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR326-2C PoE WG (without UL)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 1x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 24V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 2x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 1x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 24V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 2x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (2HR2)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC206-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] } ], "descriptions": [ { "lang": "en", "value": "Affected devices store the CLI user passwords encrypted in flash memory. Attackers with physical access to the device could retrieve the file and decrypt the CLI user passwords." } ], "metrics": [ { "cvssV3_1": { "baseScore": 5.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-257", "description": "CWE-257: Storing Passwords in a Recoverable Format", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-10-10T10:21:11.037Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-46142", "datePublished": "2022-12-13T00:00:00", "dateReserved": "2022-11-28T00:00:00", "dateUpdated": "2024-08-03T14:24:03.321Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-31765
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | RUGGEDCOM RM1224 LTE(4G) EU |
Version: All versions < V7.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:26:01.033Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-552702.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) EU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) NAM", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M804PB", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router (Annex A)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router (Annex B)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router (Annex A)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router (Annex B)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M826-2 SHDSL-Router", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3 (EVDO)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3 (ROK)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (NAM)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM853-1 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (RoW)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC622-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC632-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC636-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC642-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC646-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2 EEC M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2IA M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W721-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W721-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45 (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W738-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W738-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W761-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W761-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45 (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12 EEC (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2IA RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2IA RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM763-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 (US)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 EEC (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 EEC (US)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM763-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM763-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM766-1 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM766-1 (US)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (SC, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3LD (SC, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3LD (SC, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB208 (E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB208 (PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (SC, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (SC, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (ST, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3LD (SC, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3LD (SC, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB216 (E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB216 (PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2 (SC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2 (ST/BFOC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE EEC (54 V DC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G (EIP DEF.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G (EIP def.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-3G PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-3G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204 DNA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA DNA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-8C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-8C (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM416-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM416-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208 (Ethernet/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208PoE EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216 (Ethernet/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216POE EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324WG (24 x FE, AC 230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324WG (24 X FE, DC 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR326-2C PoE WG", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR326-2C PoE WG (without UL)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 1x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 24V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 2x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 1x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 24V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 2x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (2HR2)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC206-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] } ], "descriptions": [ { "lang": "en", "value": "Affected devices do not properly authorize the change password function of the web interface.\r\nThis could allow low privileged users to escalate their privileges." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-862", "description": "CWE-862: Missing Authorization", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-11T09:02:25.347Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-552702.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-31765", "datePublished": "2022-10-11T00:00:00", "dateReserved": "2022-05-27T00:00:00", "dateUpdated": "2024-08-03T07:26:01.033Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-36323
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | RUGGEDCOM RM1224 LTE(4G) EU |
Version: All versions < V7.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T10:00:04.366Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) EU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) NAM", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M804PB", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router (Annex A)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router (Annex B)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router (Annex A)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router (Annex B)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M826-2 SHDSL-Router", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3 (EVDO)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3 (ROK)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (NAM)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM853-1 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (RoW)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC622-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC626-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC632-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC636-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC642-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC646-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2 EEC M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2IA M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W721-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W721-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45 (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W738-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W738-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W761-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W761-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45 (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12 EEC (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2IA RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2IA RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM763-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 (US)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 EEC (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 EEC (US)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM763-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM763-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM766-1 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM766-1 (US)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (SC, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3LD (SC, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3LD (SC, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB208 (E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB208 (PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (SC, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (SC, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (ST, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3LD (SC, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3LD (SC, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB216 (E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB216 (PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2 (SC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2 (ST/BFOC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE EEC (54 V DC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G (EIP DEF.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G (EIP def.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-3G PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-3G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204 DNA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA DNA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-8C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-8C (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM416-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM416-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208 (Ethernet/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208PoE EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216 (Ethernet/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216POE EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324WG (24 x FE, AC 230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324WG (24 X FE, DC 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR326-2C PoE WG", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR326-2C PoE WG (without UL)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 1x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 24V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 2x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 1x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 24V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 2x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (2HR2)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC206-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] } ], "descriptions": [ { "lang": "en", "value": "Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell." } ], "metrics": [ { "cvssV3_1": { "baseScore": 9.1, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-74", "description": "CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-10-10T10:20:59.701Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-36323", "datePublished": "2022-08-10T11:18:33", "dateReserved": "2022-07-20T00:00:00", "dateUpdated": "2024-08-03T10:00:04.366Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-46140
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | RUGGEDCOM RM1224 LTE(4G) EU |
Version: All versions < V7.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:24:03.297Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) EU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) NAM", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M804PB", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router (Annex A)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router (Annex B)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router (Annex A)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router (Annex B)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M826-2 SHDSL-Router", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3 (EVDO)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3 (ROK)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (NAM)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM853-1 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (RoW)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC622-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC626-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC632-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC636-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC642-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC646-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2 EEC M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2IA M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W721-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W721-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45 (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W738-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W738-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W761-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W761-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45 (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12 EEC (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2IA RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2IA RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM763-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 (US)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 EEC (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 EEC (US)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM763-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM763-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM766-1 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM766-1 (US)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (SC, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3LD (SC, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3LD (SC, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB208 (E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB208 (PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (SC, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (SC, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (ST, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3LD (SC, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3LD (SC, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB216 (E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB216 (PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2 (SC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2 (ST/BFOC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE EEC (54 V DC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G (EIP DEF.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G (EIP def.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-3G PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-3G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204 DNA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA DNA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-8C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-8C (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM416-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM416-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208 (Ethernet/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208PoE EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216 (Ethernet/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216POE EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324WG (24 x FE, AC 230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324WG (24 X FE, DC 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR326-2C PoE WG", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR326-2C PoE WG (without UL)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 1x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 24V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 2x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 1x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 24V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 2x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (2HR2)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC206-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] } ], "descriptions": [ { "lang": "en", "value": "Affected devices use a weak encryption scheme to encrypt the debug zip file. This could allow an authenticated attacker to decrypt the contents of the file and retrieve debug information about the system." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-327", "description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-10-10T10:21:07.520Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-46140", "datePublished": "2022-12-13T00:00:00", "dateReserved": "2022-11-28T00:00:00", "dateUpdated": "2024-08-03T14:24:03.297Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-46143
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | RUGGEDCOM RM1224 LTE(4G) EU |
Version: 0 < V7.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:24:03.372Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) EU", "vendor": "Siemens", "versions": [ { "lessThan": "V7.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) EU", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) NAM", "vendor": "Siemens", "versions": [ { "lessThan": "V7.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) NAM", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M804PB", "vendor": "Siemens", "versions": [ { "lessThan": "V7.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M804PB", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V7.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V7.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V7.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V7.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M826-2 SHDSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V7.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M826-2 SHDSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-2", "vendor": "Siemens", "versions": [ { "lessThan": "V7.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-2", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-3", "vendor": "Siemens", "versions": [ { "lessThan": "V7.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-3", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3", "vendor": "Siemens", "versions": [ { "lessThan": "V7.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3 (ROK)", "vendor": "Siemens", "versions": [ { "lessThan": "V7.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3 (ROK)", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4", "vendor": "Siemens", "versions": [ { "lessThan": "V7.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V7.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (NAM)", "vendor": "Siemens", "versions": [ { "lessThan": "V7.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (NAM)", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM853-1 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V7.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM853-1 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V7.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (RoW)", "vendor": "Siemens", "versions": [ { "lessThan": "V7.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (RoW)", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615 EEC LAN-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V7.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615 EEC LAN-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615 LAN-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V7.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615 LAN-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC622-2C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC622-2C", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0", "status": "affected", "version": "V2.3", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC626-2C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC626-2C", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0", "status": "affected", "version": "V2.3", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC632-2C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC632-2C", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0", "status": "affected", "version": "V2.3", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC636-2C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC636-2C", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0", "status": "affected", "version": "V2.3", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC642-2C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC642-2C", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0", "status": "affected", "version": "V2.3", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC646-2C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC646-2C", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0", "status": "affected", "version": "V2.3", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1748-1 M12", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1748-1 M12", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-1 M12", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2 EEC M12", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2 M12", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2IA M12", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W721-1 RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W721-1 RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45 (USA)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W738-1 M12", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W738-1 M12", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 M12", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 M12", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W761-1 RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W761-1 RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 M12 EEC", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 M12 EEC", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45 (USA)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12 EEC", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12 EEC (USA)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-1 RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-1 RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 SFP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 SFP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2IA RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2IA RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 M12", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 M12", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM763-1", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 (US)", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 EEC (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 EEC (US)", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM763-1", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM763-1", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM766-1 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM766-1 (US)", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3LD (SC, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3LD (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB208 (E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB208 (PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (SC, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (ST, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3LD (SC, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3LD (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB216 (E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB216 (PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2 (SC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2 (ST/BFOC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE EEC (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G (EIP DEF.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G (EIP def.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-3G PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-3G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204 DNA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA DNA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V6.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-8C", "vendor": "Siemens", "versions": [ { "lessThan": "V6.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-8C (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM416-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V6.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM416-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208 (Ethernet/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208PoE EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216 (Ethernet/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216POE EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324WG (24 x FE, AC 230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324WG (24 X FE, DC 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR326-2C PoE WG", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR326-2C PoE WG (without UL)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 1x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 24V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 2x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 1x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 24V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 2x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M", "vendor": "Siemens", "versions": [ { "lessThan": "V6.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (2HR2)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M", "vendor": "Siemens", "versions": [ { "lessThan": "V6.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC206-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC208", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "Affected devices do not check the TFTP blocksize correctly. This could allow an authenticated attacker to read from an uninitialized buffer that potentially contains previously allocated data." } ], "metrics": [ { "cvssV3_1": { "baseScore": 2.7, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-1284", "description": "CWE-1284: Improper Validation of Specified Quantity in Input", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-13T07:50:25.824Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-46143", "datePublished": "2022-12-13T00:00:00", "dateReserved": "2022-11-28T00:00:00", "dateUpdated": "2024-08-13T07:50:25.824Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-36324
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | RUGGEDCOM RM1224 LTE(4G) EU |
Version: All versions < V7.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T10:00:04.354Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) EU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) NAM", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M804PB", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router (Annex A)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router (Annex B)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router (Annex A)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router (Annex B)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M826-2 SHDSL-Router", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3 (EVDO)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3 (ROK)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (NAM)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM853-1 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (RoW)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.1.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC622-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC626-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC632-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC636-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC642-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE SC646-2C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2 EEC M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2IA M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W721-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W721-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45 (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W738-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W738-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W761-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W761-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45 (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12 EEC (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2IA RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2IA RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM763-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 (US)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 EEC (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WAM766-1 EEC (US)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM763-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM763-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM766-1 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE WUM766-1 (US)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (SC, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3LD (SC, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3LD (SC, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB208 (E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB208 (PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (SC, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (SC, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (ST, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3LD (SC, E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3LD (SC, PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB216 (E/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB216 (PN)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2 (SC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2 (ST/BFOC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE EEC (54 V DC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G (EIP DEF.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G (EIP def.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-3G PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-3G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204 DNA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA DNA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-8C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-8C (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM416-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM416-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208 (Ethernet/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208PoE EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216 (Ethernet/IP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216POE EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324WG (24 x FE, AC 230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324WG (24 X FE, DC 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR326-2C PoE WG", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR326-2C PoE WG (without UL)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 1x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 24V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 2x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 1x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 24V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 2x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (2HR2)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.6" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC206-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4" } ] } ], "descriptions": [ { "lang": "en", "value": "Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-770", "description": "CWE-770: Allocation of Resources Without Limits or Throttling", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-10-10T10:21:02.321Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-36324", "datePublished": "2022-08-10T11:18:39", "dateReserved": "2022-07-20T00:00:00", "dateUpdated": "2024-08-03T10:00:04.354Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-37182
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-145224.pdf | x_refsource_MISC |
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SCALANCE XM408-4C |
Version: All versions < V6.5 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T01:16:03.731Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-145224.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SCALANCE XM408-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.5" } ] }, { "product": "SCALANCE XM408-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.5" } ] }, { "product": "SCALANCE XM408-8C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.5" } ] }, { "product": "SCALANCE XM408-8C (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.5" } ] }, { "product": "SCALANCE XM416-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.5" } ] }, { "product": "SCALANCE XM416-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.5" } ] }, { "product": "SCALANCE XR524-8C, 1x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.5" } ] }, { "product": "SCALANCE XR524-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.5" } ] }, { "product": "SCALANCE XR524-8C, 24V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.5" } ] }, { "product": "SCALANCE XR524-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.5" } ] }, { "product": "SCALANCE XR524-8C, 2x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.5" } ] }, { "product": "SCALANCE XR524-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.5" } ] }, { "product": "SCALANCE XR526-8C, 1x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.5" } ] }, { "product": "SCALANCE XR526-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.5" } ] }, { "product": "SCALANCE XR526-8C, 24V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.5" } ] }, { "product": "SCALANCE XR526-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.5" } ] }, { "product": "SCALANCE XR526-8C, 2x230V", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.5" } ] }, { "product": "SCALANCE XR526-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.5" } ] }, { "product": "SCALANCE XR528-6M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.5" } ] }, { "product": "SCALANCE XR528-6M (2HR2)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.5" } ] }, { "product": "SCALANCE XR528-6M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.5" } ] }, { "product": "SCALANCE XR528-6M (L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.5" } ] }, { "product": "SCALANCE XR552-12M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.5" } ] }, { "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.5" } ] }, { "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.5" } ] }, { "product": "SCALANCE XR552-12M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.5" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE XM408-4C (All versions \u003c V6.5), SCALANCE XM408-4C (L3 int.) (All versions \u003c V6.5), SCALANCE XM408-8C (All versions \u003c V6.5), SCALANCE XM408-8C (L3 int.) (All versions \u003c V6.5), SCALANCE XM416-4C (All versions \u003c V6.5), SCALANCE XM416-4C (L3 int.) (All versions \u003c V6.5), SCALANCE XR524-8C, 1x230V (All versions \u003c V6.5), SCALANCE XR524-8C, 1x230V (L3 int.) (All versions \u003c V6.5), SCALANCE XR524-8C, 24V (All versions \u003c V6.5), SCALANCE XR524-8C, 24V (L3 int.) (All versions \u003c V6.5), SCALANCE XR524-8C, 2x230V (All versions \u003c V6.5), SCALANCE XR524-8C, 2x230V (L3 int.) (All versions \u003c V6.5), SCALANCE XR526-8C, 1x230V (All versions \u003c V6.5), SCALANCE XR526-8C, 1x230V (L3 int.) (All versions \u003c V6.5), SCALANCE XR526-8C, 24V (All versions \u003c V6.5), SCALANCE XR526-8C, 24V (L3 int.) (All versions \u003c V6.5), SCALANCE XR526-8C, 2x230V (All versions \u003c V6.5), SCALANCE XR526-8C, 2x230V (L3 int.) (All versions \u003c V6.5), SCALANCE XR528-6M (All versions \u003c V6.5), SCALANCE XR528-6M (2HR2) (All versions \u003c V6.5), SCALANCE XR528-6M (2HR2, L3 int.) (All versions \u003c V6.5), SCALANCE XR528-6M (L3 int.) (All versions \u003c V6.5), SCALANCE XR552-12M (All versions \u003c V6.5), SCALANCE XR552-12M (2HR2) (All versions \u003c V6.5), SCALANCE XR552-12M (2HR2) (All versions \u003c V6.5), SCALANCE XR552-12M (2HR2, L3 int.) (All versions \u003c V6.5). The OSPF protocol implementation in affected devices fails to verify the checksum and length fields in the OSPF LS Update messages. An unauthenticated remote attacker could exploit this vulnerability to cause interruptions in the network by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-354", "description": "CWE-354: Improper Validation of Integrity Check Value", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-06-14T09:21:24", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-145224.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-37182", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SCALANCE XM408-4C", "version": { "version_data": [ { "version_value": "All versions \u003c V6.5" } ] } }, { "product_name": "SCALANCE XM408-4C (L3 int.)", "version": { "version_data": [ { "version_value": "All versions \u003c V6.5" } ] } }, { "product_name": "SCALANCE XM408-8C", "version": { "version_data": [ { "version_value": "All versions \u003c V6.5" } ] } }, { "product_name": "SCALANCE XM408-8C (L3 int.)", "version": { "version_data": [ { "version_value": "All versions \u003c V6.5" } ] } }, { "product_name": "SCALANCE XM416-4C", "version": { "version_data": [ { "version_value": "All versions \u003c V6.5" } ] } }, { "product_name": "SCALANCE XM416-4C (L3 int.)", "version": { "version_data": [ { "version_value": "All versions \u003c V6.5" } ] } }, { "product_name": "SCALANCE XR524-8C, 1x230V", "version": { "version_data": [ { "version_value": "All versions \u003c V6.5" } ] } }, { "product_name": "SCALANCE XR524-8C, 1x230V (L3 int.)", "version": { "version_data": [ { "version_value": "All versions \u003c V6.5" } ] } }, { "product_name": "SCALANCE XR524-8C, 24V", "version": { "version_data": [ { "version_value": "All versions \u003c V6.5" } ] } }, { "product_name": "SCALANCE XR524-8C, 24V (L3 int.)", "version": { "version_data": [ { "version_value": "All versions \u003c V6.5" } ] } }, { "product_name": "SCALANCE XR524-8C, 2x230V", "version": { "version_data": [ { "version_value": "All versions \u003c V6.5" } ] } }, { "product_name": "SCALANCE XR524-8C, 2x230V (L3 int.)", "version": { "version_data": [ { "version_value": "All versions \u003c V6.5" } ] } }, { "product_name": "SCALANCE XR526-8C, 1x230V", "version": { "version_data": [ { "version_value": "All versions \u003c V6.5" } ] } }, { "product_name": "SCALANCE XR526-8C, 1x230V (L3 int.)", "version": { "version_data": [ { "version_value": "All versions \u003c V6.5" } ] } }, { "product_name": "SCALANCE XR526-8C, 24V", "version": { "version_data": [ { "version_value": "All versions \u003c V6.5" } ] } }, { "product_name": "SCALANCE XR526-8C, 24V (L3 int.)", "version": { "version_data": [ { "version_value": "All versions \u003c V6.5" } ] } }, { "product_name": "SCALANCE XR526-8C, 2x230V", "version": { "version_data": [ { "version_value": "All versions \u003c V6.5" } ] } }, { "product_name": "SCALANCE XR526-8C, 2x230V (L3 int.)", "version": { "version_data": [ { "version_value": "All versions \u003c V6.5" } ] } }, { "product_name": "SCALANCE XR528-6M", "version": { "version_data": [ { "version_value": "All versions \u003c V6.5" } ] } }, { "product_name": "SCALANCE XR528-6M (2HR2)", "version": { "version_data": [ { "version_value": "All versions \u003c V6.5" } ] } }, { "product_name": "SCALANCE XR528-6M (2HR2, L3 int.)", "version": { "version_data": [ { "version_value": "All versions \u003c V6.5" } ] } }, { "product_name": "SCALANCE XR528-6M (L3 int.)", "version": { "version_data": [ { "version_value": "All versions \u003c V6.5" } ] } }, { "product_name": "SCALANCE XR552-12M", "version": { "version_data": [ { "version_value": "All versions \u003c V6.5" } ] } }, { "product_name": "SCALANCE XR552-12M (2HR2)", "version": { "version_data": [ { "version_value": "All versions \u003c V6.5" } ] } }, { "product_name": "SCALANCE XR552-12M (2HR2)", "version": { "version_data": [ { "version_value": "All versions \u003c V6.5" } ] } }, { "product_name": "SCALANCE XR552-12M (2HR2, L3 int.)", "version": { "version_data": [ { "version_value": "All versions \u003c V6.5" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SCALANCE XM408-4C (All versions \u003c V6.5), SCALANCE XM408-4C (L3 int.) (All versions \u003c V6.5), SCALANCE XM408-8C (All versions \u003c V6.5), SCALANCE XM408-8C (L3 int.) (All versions \u003c V6.5), SCALANCE XM416-4C (All versions \u003c V6.5), SCALANCE XM416-4C (L3 int.) (All versions \u003c V6.5), SCALANCE XR524-8C, 1x230V (All versions \u003c V6.5), SCALANCE XR524-8C, 1x230V (L3 int.) (All versions \u003c V6.5), SCALANCE XR524-8C, 24V (All versions \u003c V6.5), SCALANCE XR524-8C, 24V (L3 int.) (All versions \u003c V6.5), SCALANCE XR524-8C, 2x230V (All versions \u003c V6.5), SCALANCE XR524-8C, 2x230V (L3 int.) (All versions \u003c V6.5), SCALANCE XR526-8C, 1x230V (All versions \u003c V6.5), SCALANCE XR526-8C, 1x230V (L3 int.) (All versions \u003c V6.5), SCALANCE XR526-8C, 24V (All versions \u003c V6.5), SCALANCE XR526-8C, 24V (L3 int.) (All versions \u003c V6.5), SCALANCE XR526-8C, 2x230V (All versions \u003c V6.5), SCALANCE XR526-8C, 2x230V (L3 int.) (All versions \u003c V6.5), SCALANCE XR528-6M (All versions \u003c V6.5), SCALANCE XR528-6M (2HR2) (All versions \u003c V6.5), SCALANCE XR528-6M (2HR2, L3 int.) (All versions \u003c V6.5), SCALANCE XR528-6M (L3 int.) (All versions \u003c V6.5), SCALANCE XR552-12M (All versions \u003c V6.5), SCALANCE XR552-12M (2HR2) (All versions \u003c V6.5), SCALANCE XR552-12M (2HR2) (All versions \u003c V6.5), SCALANCE XR552-12M (2HR2, L3 int.) (All versions \u003c V6.5). The OSPF protocol implementation in affected devices fails to verify the checksum and length fields in the OSPF LS Update messages. An unauthenticated remote attacker could exploit this vulnerability to cause interruptions in the network by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-354: Improper Validation of Integrity Check Value" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-145224.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-145224.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-37182", "datePublished": "2022-06-14T09:21:24", "dateReserved": "2021-07-21T00:00:00", "dateUpdated": "2024-08-04T01:16:03.731Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-28400
Vulnerability from cvelistv5
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller |
Version: All versions |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_b:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m812-1_adsl-router_annex_b", "vendor": "seimens", "versions": [ { "status": "affected", "version": "0" } ] }, { "cpes": [ "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_dk_standard_ethernet_controller:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "development_evaluation_kits_for_profinet_io_dk_standard_ethernet_controller", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_ek_ertec_200:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "development_evaluation_kits_for_profinet_io_ek_ertec_200", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_ek_ertec_200p:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "development_evaluation_kits_for_profinet_io_ek_ertec_200p", "vendor": "siemens", "versions": [ { "lessThan": "v4.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:ruggedcom_rm1224:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ruggedcom_rm1224", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:scalance_m804pb:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m804pb", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_a:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m812-1_adsl-router_annex_a", "vendor": "seimens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_b:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m812-1_adsl-router_annex_b", "vendor": "seimens", "versions": [ { "lessThan": "6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m816_1_adsl_router_annex_a:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m816_1_adsl_router_annex_a", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m816-1_adsl-router_annex_b:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m816-1_adsl-router_annex_b", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m826-2_shdsl-router:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m826-2_shdsl-router", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_m874_2:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_m874_2", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_m874_3:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_m874_3", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m876_3_evdo:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m876_3_evdo", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m876_3_rok:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m876_3_rok", "vendor": "siemens", "versions": [ { "lessThan": "6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m876_4_eu:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m876_4_eu", "vendor": "siemens", "versions": [ { "lessThan": "6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m876_4_nam:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m876_4_nam", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_s615", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w700_ieee_802.11n_family:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w700_ieee_802.11n_family", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1748_1_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1748_1_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1788_1_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1788_1_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1788_2_eec_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1788_2_eec_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1788_2_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1788_2_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1788_2ia_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1788_2ia_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_x200_4p_irt:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_x200_4p_irt", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_x201_3p_irt:0.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_x201_3p_irt", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_x201_3p_irt_pro:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_x201_3p_irt_pro", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalancce_x202_2p_irt:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalancce_x202_2p_irt", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_202_2p_irt_pro:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_202_2p_irt_pro", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalancce_x204_2:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalancce_x204_2", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_x204_2fm:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_x204_2fm", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_x204_2ld:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_x204_2ld", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_x204_2ld_ts:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_x204_2ld_ts", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_x204_2ts:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_x204_2ts", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2020-28400", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-06-13T18:59:11.953107Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-24T18:07:44.485Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-04T16:33:59.218Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7" } ] }, { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) EU", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) NAM", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M804PB", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M826-2 SHDSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-2", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-3", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-3 3G-Router (CN)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3 (ROK)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (NAM)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM853-1 (A1)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM853-1 (B1)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM853-1 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (A1)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (B1)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (CN)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (RoW)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615 EEC LAN-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615 LAN-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2 EEC M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2IA M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W721-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W721-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45 (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W738-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W738-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W761-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W761-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45 (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12 EEC (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2IA RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2IA RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X200-4P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2FM", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2LD", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2LD TS", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2TS", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X206-1", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X206-1LD", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X208", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X208PRO", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X212-2", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X212-2LD", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X216", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X224", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (230V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (24V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 230V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 24V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X304-2FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X306-1LD FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (230V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (24V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 230V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 24V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3LD", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3LD", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LD", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LD", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH+", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH+", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M TS", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M TS", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X320-1 FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X320-1-2LD FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X408-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3LD (SC, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3LD (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB208 (E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB208 (PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (SC, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (ST, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3LD (SC, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3LD (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB216 (E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB216 (PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2 (SC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2 (ST/BFOC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE EEC (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G (EIP DEF.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G (EIP def.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-3G PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-3G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204 DNA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA DNA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF206-1", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF208", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-8C", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-8C (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM416-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM416-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208 (Ethernet/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208PoE EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216 (Ethernet/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216POE EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M TS (24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M TS (24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (230V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324WG (24 x FE, AC 230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324WG (24 X FE, DC 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR326-2C PoE WG", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR326-2C PoE WG (without UL)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 1x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 24V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 2x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 1x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 24V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 2x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (2HR2)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CFU DIQ", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CFU PA", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CM 1542-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1604", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003e= V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1616", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003e= V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1626", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC IE/PB-LINK", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV540 H", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV540 S", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV550 H", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV550 S", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV560 U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV560 X", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET DK-16xx PN IO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003e= V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Power Line Booster PLB, Base Module", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PROFINET Driver", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V4.5" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC206-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC208", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SOFTNET-IE PNIO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-770", "description": "CWE-770: Allocation of Resources Without Limits or Throttling", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-10T13:53:22.763Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-28400", "datePublished": "2021-07-13T11:02:49", "dateReserved": "2020-11-10T00:00:00", "dateUpdated": "2024-12-10T13:53:22.763Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
var-202212-1136
Vulnerability from variot
Affected devices do not check the TFTP blocksize correctly. This could allow an authenticated attacker to read from an uninitialized buffer that potentially contains previously allocated data. ruggedcom rm1224 lte(4g) eu firmware, ruggedcom rm1224 lte(4g) nam firmware, scalance m804pb Multiple Siemens products, including firmware, contain a vulnerability related to improper validation of quantities specified in input.Information may be obtained. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers.
The Siemens SCALANCE M-800/S615 series has an information disclosure vulnerability due to the affected device not properly checking the TFTP block size
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202212-1136", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "scalance m876-4", "scope": "lt", "trust": 1.8, "vendor": "siemens", "version": "v8.0" }, { "model": "scalance m812-1 adsl-router", "scope": "lt", "trust": 1.2, "vendor": "siemens", "version": "v8.0" }, { "model": "scalance m816-1 adsl-router", "scope": "lt", "trust": 1.2, "vendor": "siemens", "version": "v8.0" }, { "model": "scalance m876-3", "scope": "lt", "trust": 1.2, "vendor": "siemens", "version": "v8.0" }, { "model": "scalance mum856-1", "scope": "lt", "trust": 1.2, "vendor": "siemens", "version": "v8.0" }, { "model": "scalance w778-1 m12 eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w788-2 m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance m812-1 adsl-router", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc206-2g poe eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance sc636-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3" }, { "model": "scalance xp208eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w1788-2 eec m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w788-1 m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xb213-3ld", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w761-1 rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w774-1 m12 eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w1788-2ia m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xf204-2ba", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc208 eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xp216poe eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc224", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc216-4c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance mum853-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance w786-2 sfp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xp216eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "siplus net scalance xc208", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "ruggedcom rm1224 lte\\ eu", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr326-2c poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xb213-3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w721-1 rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc206-2sfp eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "siplus net scalance xc216-4c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance wam766-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w1788-2 m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xp208", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xr328-4c wg", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xb205-3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w788-1 rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc224-4c g eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc216", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance m816-1 adsl-router", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance s615 eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance m804pb", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr524-8c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "siplus net scalance xc206-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc206-2g poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance sc622-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3" }, { "model": "ruggedcom rm1224 lte\\ nam", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance w786-2ia rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc216eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance wum763-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance wum766-1 6ghz", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc216-4c g", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance m876-4", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204 dna", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance wam766-1 6ghz", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance m826-2 shdsl-router", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xm416-4c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w738-1 m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance w1788-1 m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xp208poe eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc208 poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xr526-8c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc206-2sfp g eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance wam766-1 ecc", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w748-1 m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc224-4c g", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w774-1 rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xr552-12m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance s615", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance w722-1 rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xm408-4c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc206-2sfp g", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w774-1 m12 rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance sc632-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3" }, { "model": "scalance w734-1 rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance sc646-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3" }, { "model": "scalance m874-3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance sc626-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3" }, { "model": "scalance xc216-3g poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w786-2 rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xr528-6m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w1748-1 m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w786-1 rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xm408-8c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance m874-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance wam763-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w778-1 m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance wum766-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc206-2sfp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc208", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xp216", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance sc642-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3" }, { "model": "scalance xb216", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc216-4c g eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xr324wg", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc206-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xr326-2c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "siplus net scalance xc206-2sfp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w788-2 m12 eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance mum856-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance m876-3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xb208", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xf204", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xb205-3ld", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xf204-2bca dna", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance s615 eec", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m812-1 adsl-router", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m876-4", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance s615", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "ruggedcom rm1224 lte eu", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc-622-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc-636-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "ruggedcom rm1224 lte nam", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m816-1 adsl-router", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance mum856-1", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m876-3", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc626-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m874-3", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc-642-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance mum853-1", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m826-2 shdsl-router", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m804pb", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc-646-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc-632-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m874-2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "ruggedcom rm1224 lte eu", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v8.0" }, { "model": "ruggedcom rm1224 lte nam", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v8.0" }, { "model": "scalance m804pb", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v8.0" }, { "model": "scalance m826-2 shdsl-router", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v8.0" }, { "model": "scalance m874-2", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v8.0" }, { "model": "scalance m874-3", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v8.0" }, { "model": "scalance mum853-1", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v8.0" }, { "model": "scalance s615", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v8.0" }, { "model": "scalance s615 eec", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v8.0" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97251" }, { "db": "JVNDB", "id": "JVNDB-2022-023553" }, { "db": "NVD", "id": "CVE-2022-46143" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-3089" } ], "trust": 0.6 }, "cve": "CVE-2022-46143", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "MULTIPLE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.4, "id": "CNVD-2023-97251", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:M/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "productcert@siemens.com", "availabilityImpact": "NONE", "baseScore": 2.7, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "exploitabilityScore": 1.2, "id": "CVE-2022-46143", "impactScore": 1.4, "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "OTHER", "availabilityImpact": "None", "baseScore": 2.7, "baseSeverity": "Low", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2022-023553", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "productcert@siemens.com", "id": "CVE-2022-46143", "trust": 1.0, "value": "LOW" }, { "author": "nvd@nist.gov", "id": "CVE-2022-46143", "trust": 1.0, "value": "LOW" }, { "author": "OTHER", "id": "JVNDB-2022-023553", "trust": 0.8, "value": "Low" }, { "author": "CNVD", "id": "CNVD-2023-97251", "trust": 0.6, "value": "LOW" }, { "author": "CNNVD", "id": "CNNVD-202212-3089", "trust": 0.6, "value": "LOW" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97251" }, { "db": "JVNDB", "id": "JVNDB-2022-023553" }, { "db": "CNNVD", "id": "CNNVD-202212-3089" }, { "db": "NVD", "id": "CVE-2022-46143" }, { "db": "NVD", "id": "CVE-2022-46143" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Affected devices do not check the TFTP blocksize correctly. This could allow an authenticated attacker to read from an uninitialized buffer that potentially contains previously allocated data. ruggedcom rm1224 lte(4g) eu firmware, ruggedcom rm1224 lte(4g) nam firmware, scalance m804pb Multiple Siemens products, including firmware, contain a vulnerability related to improper validation of quantities specified in input.Information may be obtained. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers. \n\r\n\r\nThe Siemens SCALANCE M-800/S615 series has an information disclosure vulnerability due to the affected device not properly checking the TFTP block size", "sources": [ { "db": "NVD", "id": "CVE-2022-46143" }, { "db": "JVNDB", "id": "JVNDB-2022-023553" }, { "db": "CNVD", "id": "CNVD-2023-97251" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-46143", "trust": 3.8 }, { "db": "SIEMENS", "id": "SSA-413565", "trust": 2.4 }, { "db": "SIEMENS", "id": "SSA-180704", "trust": 1.6 }, { "db": "ICS CERT", "id": "ICSA-22-349-04", "trust": 1.4 }, { "db": "JVN", "id": "JVNVU91561630", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2022-023553", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-97251", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202212-3089", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97251" }, { "db": "JVNDB", "id": "JVNDB-2022-023553" }, { "db": "CNNVD", "id": "CNNVD-202212-3089" }, { "db": "NVD", "id": "CVE-2022-46143" } ] }, "id": "VAR-202212-1136", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-97251" } ], "trust": 1.2398166874999998 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97251" } ] }, "last_update_date": "2024-08-14T12:11:36.523000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens SCALANCE M-800/S615 series information leakage vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/500346" }, { "title": "Siemens part of the product Security vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=218338" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97251" }, { "db": "CNNVD", "id": "CNNVD-202212-3089" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-1284", "trust": 1.0 }, { "problemtype": "Improper validation of quantity specified in input (CWE-1284) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-023553" }, { "db": "NVD", "id": "CVE-2022-46143" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf" }, { "trust": 1.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html" }, { "trust": 1.0, "url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html" }, { "trust": 1.0, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu91561630/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-46143" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-349-04" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-349-04" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-46143/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97251" }, { "db": "JVNDB", "id": "JVNDB-2022-023553" }, { "db": "CNNVD", "id": "CNNVD-202212-3089" }, { "db": "NVD", "id": "CVE-2022-46143" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-97251" }, { "db": "JVNDB", "id": "JVNDB-2022-023553" }, { "db": "CNNVD", "id": "CNNVD-202212-3089" }, { "db": "NVD", "id": "CVE-2022-46143" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-14T00:00:00", "db": "CNVD", "id": "CNVD-2023-97251" }, { "date": "2023-11-29T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-023553" }, { "date": "2022-12-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202212-3089" }, { "date": "2022-12-13T16:15:25.137000", "db": "NVD", "id": "CVE-2022-46143" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-13T00:00:00", "db": "CNVD", "id": "CNVD-2023-97251" }, { "date": "2023-11-29T03:03:00", "db": "JVNDB", "id": "JVNDB-2022-023553" }, { "date": "2022-12-20T00:00:00", "db": "CNNVD", "id": "CNNVD-202212-3089" }, { "date": "2024-08-13T08:15:05.483000", "db": "NVD", "id": "CVE-2022-46143" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-3089" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Vulnerability in multiple Siemens products related to improper validation of quantities specified in inputs", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-023553" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-3089" } ], "trust": 0.6 } }
var-202212-1133
Vulnerability from variot
Affected devices use a weak encryption scheme to encrypt the debug zip file. This could allow an authenticated attacker to decrypt the contents of the file and retrieve debug information about the system. ruggedcom rm1224 lte(4g) eu firmware, ruggedcom rm1224 lte(4g) nam firmware, scalance m804pb Multiple Siemens products, including firmware, contain vulnerabilities related to the use of cryptographic algorithms.Information may be obtained
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202212-1133", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "scalance xr552-12m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance wam766-1 ecc", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xm416-4c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xr326-2c poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance sc642-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3" }, { "model": "scalance xc224-4c g eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xr328-4c wg", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w734-1 rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "siplus net scalance xc206-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance sc632-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3" }, { "model": "scalance w788-1 rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "siplus net scalance xc208", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xp208poe eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w738-1 m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr524-8c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance s615 eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance m874-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc206-2sfp eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance sc646-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3" }, { "model": "ruggedcom rm1224 lte\\ eu", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204-2bca dna", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc224", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xb208", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc206-2g poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc224-4c g", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w786-1 rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w748-1 m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance w786-2 sfp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc216-4c g eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "siplus net scalance xc206-2sfp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance wum766-1 6ghz", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xp208", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance m826-2 shdsl-router", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance w778-1 m12 eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xr528-6m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance m876-3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr326-2c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w778-1 m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w788-2 m12 eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xb213-3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance wum766-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xp216eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance sc636-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3" }, { "model": "scalance w788-2 m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance mum853-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "siplus net scalance xc216-4c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc216-4c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc206-2sfp g eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance m804pb", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance w774-1 rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w1788-2ia m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xr526-8c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc206-2g poe eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc216-4c g", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w721-1 rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance mum856-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "ruggedcom rm1224 lte\\ nam", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xb205-3ld", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xb216", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance m874-3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204-2ba", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w1788-2 eec m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xb205-3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w786-2 rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance sc622-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3" }, { "model": "scalance w761-1 rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc216-3g poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xf204 dna", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance s615", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance wum763-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xr324wg", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance wam763-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xm408-8c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc206-2sfp g", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w774-1 m12 eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance wam766-1 6ghz", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w786-2ia rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance m812-1 adsl-router", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance wam766-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w774-1 m12 rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xb213-3ld", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc206-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xm408-4c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance m816-1 adsl-router", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance w788-1 m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xp208eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w1788-2 m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w722-1 rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance w1748-1 m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc208 poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance m876-4", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc206-2sfp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w1788-1 m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc208", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc216", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance sc626-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3" }, { "model": "scalance xc216eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc208 eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xp216", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xf204", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xp216poe eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance s615 eec", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m812-1 adsl-router", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m876-4", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance s615", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "ruggedcom rm1224 lte eu", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc-622-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc-636-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "ruggedcom rm1224 lte nam", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m816-1 adsl-router", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance mum856-1", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m876-3", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc626-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m874-3", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc-642-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance mum853-1", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m826-2 shdsl-router", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m804pb", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc-646-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc-632-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m874-2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-023551" }, { "db": "NVD", "id": "CVE-2022-46140" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-3091" } ], "trust": 0.6 }, "cve": "CVE-2022-46140", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "productcert@siemens.com", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2022-46140", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "OTHER", "availabilityImpact": "None", "baseScore": 6.5, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2022-023551", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "productcert@siemens.com", "id": "CVE-2022-46140", "trust": 1.0, "value": "MEDIUM" }, { "author": "nvd@nist.gov", "id": "CVE-2022-46140", "trust": 1.0, "value": "MEDIUM" }, { "author": "OTHER", "id": "JVNDB-2022-023551", "trust": 0.8, "value": "Medium" }, { "author": "CNNVD", "id": "CNNVD-202212-3091", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-023551" }, { "db": "CNNVD", "id": "CNNVD-202212-3091" }, { "db": "NVD", "id": "CVE-2022-46140" }, { "db": "NVD", "id": "CVE-2022-46140" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Affected devices use a weak encryption scheme to encrypt the debug zip file. This could allow an authenticated attacker to decrypt the contents of the file and retrieve debug information about the system. ruggedcom rm1224 lte(4g) eu firmware, ruggedcom rm1224 lte(4g) nam firmware, scalance m804pb Multiple Siemens products, including firmware, contain vulnerabilities related to the use of cryptographic algorithms.Information may be obtained", "sources": [ { "db": "NVD", "id": "CVE-2022-46140" }, { "db": "JVNDB", "id": "JVNDB-2022-023551" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-46140", "trust": 3.2 }, { "db": "SIEMENS", "id": "SSA-413565", "trust": 2.4 }, { "db": "ICS CERT", "id": "ICSA-22-349-04", "trust": 1.4 }, { "db": "JVN", "id": "JVNVU91561630", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2022-023551", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202212-3091", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-023551" }, { "db": "CNNVD", "id": "CNNVD-202212-3091" }, { "db": "NVD", "id": "CVE-2022-46140" } ] }, "id": "VAR-202212-1133", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.6398166875 }, "last_update_date": "2024-08-14T12:05:03.547000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Siemens part of the product Fixes for encryption problem vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=218340" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-3091" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-327", "trust": 1.0 }, { "problemtype": "Use of incomplete or dangerous cryptographic algorithms (CWE-327) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-023551" }, { "db": "NVD", "id": "CVE-2022-46140" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu91561630/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-46140" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-349-04" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-46140/" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-349-04" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-023551" }, { "db": "CNNVD", "id": "CNNVD-202212-3091" }, { "db": "NVD", "id": "CVE-2022-46140" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2022-023551" }, { "db": "CNNVD", "id": "CNNVD-202212-3091" }, { "db": "NVD", "id": "CVE-2022-46140" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-11-29T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-023551" }, { "date": "2022-12-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202212-3091" }, { "date": "2022-12-13T16:15:25.007000", "db": "NVD", "id": "CVE-2022-46140" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-11-29T03:03:00", "db": "JVNDB", "id": "JVNDB-2022-023551" }, { "date": "2022-12-20T00:00:00", "db": "CNNVD", "id": "CNNVD-202212-3091" }, { "date": "2023-03-14T10:15:23.297000", "db": "NVD", "id": "CVE-2022-46140" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-3091" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Vulnerabilities related to the use of cryptographic algorithms in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-023551" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "encryption problem", "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-3091" } ], "trust": 0.6 } }
var-202212-1134
Vulnerability from variot
Affected devices store the CLI user passwords encrypted in flash memory. Attackers with physical access to the device could retrieve the file and decrypt the CLI user passwords. ruggedcom rm1224 lte(4g) eu firmware, ruggedcom rm1224 lte(4g) nam firmware, scalance m804pb Multiple Siemens products, including firmware, contain vulnerabilities related to storing passwords in a recoverable format.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202212-1134", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "scalance xr552-12m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance wam766-1 ecc", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xm416-4c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xr326-2c poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance sc642-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3" }, { "model": "scalance xc224-4c g eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xr328-4c wg", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w734-1 rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "siplus net scalance xc206-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance sc632-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3" }, { "model": "scalance w788-1 rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "siplus net scalance xc208", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xp208poe eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w738-1 m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr524-8c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance s615 eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance m874-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc206-2sfp eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance sc646-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3" }, { "model": "ruggedcom rm1224 lte\\ eu", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204-2bca dna", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc224", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xb208", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc206-2g poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc224-4c g", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w786-1 rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w748-1 m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance w786-2 sfp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc216-4c g eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "siplus net scalance xc206-2sfp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance wum766-1 6ghz", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xp208", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance m826-2 shdsl-router", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance w778-1 m12 eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xr528-6m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance m876-3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr326-2c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w778-1 m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w788-2 m12 eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xb213-3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance wum766-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xp216eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance sc636-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3" }, { "model": "scalance w788-2 m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance mum853-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "siplus net scalance xc216-4c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc216-4c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc206-2sfp g eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance m804pb", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance w774-1 rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w1788-2ia m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xr526-8c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc206-2g poe eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc216-4c g", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w721-1 rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance mum856-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "ruggedcom rm1224 lte\\ nam", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xb205-3ld", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xb216", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance m874-3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204-2ba", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w1788-2 eec m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xb205-3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w786-2 rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance sc622-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3" }, { "model": "scalance w761-1 rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc216-3g poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xf204 dna", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance s615", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance wum763-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xr324wg", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance wam763-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xm408-8c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc206-2sfp g", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w774-1 m12 eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance wam766-1 6ghz", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w786-2ia rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance m812-1 adsl-router", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance wam766-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w774-1 m12 rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xb213-3ld", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc206-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xm408-4c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance m816-1 adsl-router", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance w788-1 m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xp208eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w1788-2 m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w722-1 rj45", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance w1748-1 m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc208 poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance m876-4", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc206-2sfp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance w1788-1 m12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc208", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc216", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance sc626-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3" }, { "model": "scalance xc216eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xc208 eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xp216", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xf204", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xp216poe eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance s615 eec", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m812-1 adsl-router", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m876-4", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance s615", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "ruggedcom rm1224 lte eu", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc-622-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc-636-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "ruggedcom rm1224 lte nam", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m816-1 adsl-router", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance mum856-1", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m876-3", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc626-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m874-3", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc-642-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance mum853-1", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m826-2 shdsl-router", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m804pb", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc-646-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc-632-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m874-2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-023552" }, { "db": "NVD", "id": "CVE-2022-46142" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-3090" } ], "trust": 0.6 }, "cve": "CVE-2022-46142", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "PHYSICAL", "author": "productcert@siemens.com", "availabilityImpact": "LOW", "baseScore": 5.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "id": "CVE-2022-46142", "impactScore": 4.7, "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "PHYSICAL", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 4.6, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "id": "CVE-2022-46142", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Physical", "author": "OTHER", "availabilityImpact": "Low", "baseScore": 5.7, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2022-023552", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L", "version": "3.0" } ], "severity": [ { "author": "productcert@siemens.com", "id": "CVE-2022-46142", "trust": 1.0, "value": "MEDIUM" }, { "author": "nvd@nist.gov", "id": "CVE-2022-46142", "trust": 1.0, "value": "MEDIUM" }, { "author": "OTHER", "id": "JVNDB-2022-023552", "trust": 0.8, "value": "Medium" }, { "author": "CNNVD", "id": "CNNVD-202212-3090", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-023552" }, { "db": "CNNVD", "id": "CNNVD-202212-3090" }, { "db": "NVD", "id": "CVE-2022-46142" }, { "db": "NVD", "id": "CVE-2022-46142" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Affected devices store the CLI user passwords encrypted in flash memory. Attackers with physical access to the device could retrieve the file and decrypt the CLI user passwords. ruggedcom rm1224 lte(4g) eu firmware, ruggedcom rm1224 lte(4g) nam firmware, scalance m804pb Multiple Siemens products, including firmware, contain vulnerabilities related to storing passwords in a recoverable format.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2022-46142" }, { "db": "JVNDB", "id": "JVNDB-2022-023552" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-46142", "trust": 3.2 }, { "db": "SIEMENS", "id": "SSA-413565", "trust": 2.4 }, { "db": "ICS CERT", "id": "ICSA-22-349-04", "trust": 1.4 }, { "db": "JVN", "id": "JVNVU91561630", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2022-023552", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202212-3090", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-023552" }, { "db": "CNNVD", "id": "CNNVD-202212-3090" }, { "db": "NVD", "id": "CVE-2022-46142" } ] }, "id": "VAR-202212-1134", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.6398166875 }, "last_update_date": "2024-08-14T12:13:17.100000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Siemens part of the product Security vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=218339" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-3090" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-257", "trust": 1.0 }, { "problemtype": "CWE-522", "trust": 1.0 }, { "problemtype": "Password storage in recoverable form (CWE-257) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-023552" }, { "db": "NVD", "id": "CVE-2022-46142" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu91561630/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-46142" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-349-04" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-349-04" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-46142/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-023552" }, { "db": "CNNVD", "id": "CNNVD-202212-3090" }, { "db": "NVD", "id": "CVE-2022-46142" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2022-023552" }, { "db": "CNNVD", "id": "CNNVD-202212-3090" }, { "db": "NVD", "id": "CVE-2022-46142" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-11-29T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-023552" }, { "date": "2022-12-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202212-3090" }, { "date": "2022-12-13T16:15:25.067000", "db": "NVD", "id": "CVE-2022-46142" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-11-29T03:03:00", "db": "JVNDB", "id": "JVNDB-2022-023552" }, { "date": "2023-03-15T00:00:00", "db": "CNNVD", "id": "CNNVD-202212-3090" }, { "date": "2023-03-14T10:15:24.137000", "db": "NVD", "id": "CVE-2022-46142" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Recoverable password storage vulnerability in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-023552" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-3090" } ], "trust": 0.6 } }
var-202206-1063
Vulnerability from variot
A vulnerability has been identified in SCALANCE XM408-4C (All versions < V6.5), SCALANCE XM408-4C (L3 int.) (All versions < V6.5), SCALANCE XM408-8C (All versions < V6.5), SCALANCE XM408-8C (L3 int.) (All versions < V6.5), SCALANCE XM416-4C (All versions < V6.5), SCALANCE XM416-4C (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 1x230V (All versions < V6.5), SCALANCE XR524-8C, 1x230V (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 24V (All versions < V6.5), SCALANCE XR524-8C, 24V (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 2x230V (All versions < V6.5), SCALANCE XR524-8C, 2x230V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 1x230V (All versions < V6.5), SCALANCE XR526-8C, 1x230V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 24V (All versions < V6.5), SCALANCE XR526-8C, 24V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 2x230V (All versions < V6.5), SCALANCE XR526-8C, 2x230V (L3 int.) (All versions < V6.5), SCALANCE XR528-6M (All versions < V6.5), SCALANCE XR528-6M (2HR2) (All versions < V6.5), SCALANCE XR528-6M (2HR2, L3 int.) (All versions < V6.5), SCALANCE XR528-6M (L3 int.) (All versions < V6.5), SCALANCE XR552-12M (All versions < V6.5), SCALANCE XR552-12M (2HR2) (All versions < V6.5), SCALANCE XR552-12M (2HR2) (All versions < V6.5), SCALANCE XR552-12M (2HR2, L3 int.) (All versions < V6.5). The OSPF protocol implementation in affected devices fails to verify the checksum and length fields in the OSPF LS Update messages. An unauthenticated remote attacker could exploit this vulnerability to cause interruptions in the network by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device. SCALANCE XM-408-4C firmware, scalance xm408-4c l3 firmware, SCALANCE XM-408-8C Multiple Siemens products such as firmware contain vulnerabilities related to insufficient data integrity verification.Service operation interruption (DoS) It may be in a state. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLCs) or human-machine interfaces (HMIs)
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202206-1063", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "scalance xr552-12m", "scope": "lt", "trust": 3.4, "vendor": "siemens", "version": "6.5" }, { "model": "scalance xr528-6m", "scope": "lt", "trust": 3.4, "vendor": "siemens", "version": "6.5" }, { "model": "scalance xm416-4c", "scope": "lt", "trust": 2.2, "vendor": "siemens", "version": "6.5" }, { "model": "scalance xm408-8c", "scope": "lt", "trust": 2.2, "vendor": "siemens", "version": "6.5" }, { "model": "scalance xm408-4c", "scope": "lt", "trust": 2.2, "vendor": "siemens", "version": "6.5" }, { "model": "scalance xr526-8c,2x230v", "scope": "lt", "trust": 1.2, "vendor": "siemens", "version": "6.5" }, { "model": "scalance xr526-8c,1x230v", "scope": "lt", "trust": 1.2, "vendor": "siemens", "version": "6.5" }, { "model": "scalance xr524-8c,2x230v", "scope": "lt", "trust": 1.2, "vendor": "siemens", "version": "6.5" }, { "model": "scalance xr524-8c,1x230v", "scope": "lt", "trust": 1.2, "vendor": "siemens", "version": "6.5" }, { "model": "scalance xr528-6m l3", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.5" }, { "model": "scalance xr526-8c l3", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.5" }, { "model": "scalance xm408-8c l3", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.5" }, { "model": "scalance xm408-4c l3", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.5" }, { "model": "scalance xr552-12m 2hr2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.5" }, { "model": "scalance xr526-8c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.5" }, { "model": "scalance xr528-6m 2hr2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.5" }, { "model": "scalance xr528-6m 2hr2 l3", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.5" }, { "model": "scalance xr552-12m 2hr2 l3", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.5" }, { "model": "scalance xm416-4c l3", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.5" }, { "model": "scalance xr524-8c l3", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.5" }, { "model": "scalance xr524-8c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.5" }, { "model": "scalance xr524-8c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xm-408-8c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xr526-8c l3", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xm-426-4c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xm-416-4c 13", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xm-408-4c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xr524-8c l3", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xm408-4c l3", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xr526-8c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xm-408-8c 13", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xr526-8c", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "24v\u003c6.5" }, { "model": "scalance xr526-8c,24v", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "6.5" }, { "model": "scalance xr524-8c", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "24v\u003c6.5" }, { "model": "scalance xr524-8c,24v", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "6.5" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-45235" }, { "db": "JVNDB", "id": "JVNDB-2021-019921" }, { "db": "NVD", "id": "CVE-2021-37182" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported this vulnerability to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202206-1281" } ], "trust": 0.6 }, "cve": "CVE-2021-37182", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 4.3, "confidentialityImpact": "NONE", "exploitabilityScore": 8.6, "id": "CVE-2021-37182", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "HIGH", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 5.4, "confidentialityImpact": "NONE", "exploitabilityScore": 4.9, "id": "CNVD-2022-45235", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:H/Au:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2021-37182", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-37182", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-37182", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2021-37182", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2022-45235", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202206-1281", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-37182", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-45235" }, { "db": "VULMON", "id": "CVE-2021-37182" }, { "db": "JVNDB", "id": "JVNDB-2021-019921" }, { "db": "CNNVD", "id": "CNNVD-202206-1281" }, { "db": "NVD", "id": "CVE-2021-37182" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SCALANCE XM408-4C (All versions \u003c V6.5), SCALANCE XM408-4C (L3 int.) (All versions \u003c V6.5), SCALANCE XM408-8C (All versions \u003c V6.5), SCALANCE XM408-8C (L3 int.) (All versions \u003c V6.5), SCALANCE XM416-4C (All versions \u003c V6.5), SCALANCE XM416-4C (L3 int.) (All versions \u003c V6.5), SCALANCE XR524-8C, 1x230V (All versions \u003c V6.5), SCALANCE XR524-8C, 1x230V (L3 int.) (All versions \u003c V6.5), SCALANCE XR524-8C, 24V (All versions \u003c V6.5), SCALANCE XR524-8C, 24V (L3 int.) (All versions \u003c V6.5), SCALANCE XR524-8C, 2x230V (All versions \u003c V6.5), SCALANCE XR524-8C, 2x230V (L3 int.) (All versions \u003c V6.5), SCALANCE XR526-8C, 1x230V (All versions \u003c V6.5), SCALANCE XR526-8C, 1x230V (L3 int.) (All versions \u003c V6.5), SCALANCE XR526-8C, 24V (All versions \u003c V6.5), SCALANCE XR526-8C, 24V (L3 int.) (All versions \u003c V6.5), SCALANCE XR526-8C, 2x230V (All versions \u003c V6.5), SCALANCE XR526-8C, 2x230V (L3 int.) (All versions \u003c V6.5), SCALANCE XR528-6M (All versions \u003c V6.5), SCALANCE XR528-6M (2HR2) (All versions \u003c V6.5), SCALANCE XR528-6M (2HR2, L3 int.) (All versions \u003c V6.5), SCALANCE XR528-6M (L3 int.) (All versions \u003c V6.5), SCALANCE XR552-12M (All versions \u003c V6.5), SCALANCE XR552-12M (2HR2) (All versions \u003c V6.5), SCALANCE XR552-12M (2HR2) (All versions \u003c V6.5), SCALANCE XR552-12M (2HR2, L3 int.) (All versions \u003c V6.5). The OSPF protocol implementation in affected devices fails to verify the checksum and length fields in the OSPF LS Update messages. An unauthenticated remote attacker could exploit this vulnerability to cause interruptions in the network by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device. SCALANCE XM-408-4C firmware, scalance xm408-4c l3 firmware, SCALANCE XM-408-8C Multiple Siemens products such as firmware contain vulnerabilities related to insufficient data integrity verification.Service operation interruption (DoS) It may be in a state. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLCs) or human-machine interfaces (HMIs)", "sources": [ { "db": "NVD", "id": "CVE-2021-37182" }, { "db": "JVNDB", "id": "JVNDB-2021-019921" }, { "db": "CNVD", "id": "CNVD-2022-45235" }, { "db": "VULMON", "id": "CVE-2021-37182" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-37182", "trust": 3.9 }, { "db": "SIEMENS", "id": "SSA-145224", "trust": 3.1 }, { "db": "ICS CERT", "id": "ICSA-22-167-10", "trust": 1.5 }, { "db": "JVN", "id": "JVNVU99030761", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-019921", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2022-45235", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202206-1281", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-37182", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-45235" }, { "db": "VULMON", "id": "CVE-2021-37182" }, { "db": "JVNDB", "id": "JVNDB-2021-019921" }, { "db": "CNNVD", "id": "CNNVD-202206-1281" }, { "db": "NVD", "id": "CVE-2021-37182" } ] }, "id": "VAR-202206-1063", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2022-45235" } ], "trust": 1.3421461558333332 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-45235" } ] }, "last_update_date": "2024-08-14T12:13:37.693000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Siemens SCALANCE Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=198105" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202206-1281" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-354", "trust": 1.0 }, { "problemtype": "Incomplete data integrity verification (CWE-354) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-019921" }, { "db": "NVD", "id": "CVE-2021-37182" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-145224.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu99030761/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-37182" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-167-10" }, { "trust": 0.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-145224.html" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2021-37182/" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-167-10" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/354.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-10" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-45235" }, { "db": "VULMON", "id": "CVE-2021-37182" }, { "db": "JVNDB", "id": "JVNDB-2021-019921" }, { "db": "CNNVD", "id": "CNNVD-202206-1281" }, { "db": "NVD", "id": "CVE-2021-37182" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2022-45235" }, { "db": "VULMON", "id": "CVE-2021-37182" }, { "db": "JVNDB", "id": "JVNDB-2021-019921" }, { "db": "CNNVD", "id": "CNNVD-202206-1281" }, { "db": "NVD", "id": "CVE-2021-37182" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-06-15T00:00:00", "db": "CNVD", "id": "CNVD-2022-45235" }, { "date": "2022-06-14T00:00:00", "db": "VULMON", "id": "CVE-2021-37182" }, { "date": "2023-08-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-019921" }, { "date": "2022-06-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202206-1281" }, { "date": "2022-06-14T10:15:17.747000", "db": "NVD", "id": "CVE-2021-37182" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-06-15T00:00:00", "db": "CNVD", "id": "CNVD-2022-45235" }, { "date": "2022-06-27T00:00:00", "db": "VULMON", "id": "CVE-2021-37182" }, { "date": "2023-08-25T08:15:00", "db": "JVNDB", "id": "JVNDB-2021-019921" }, { "date": "2022-06-30T00:00:00", "db": "CNNVD", "id": "CNNVD-202206-1281" }, { "date": "2022-06-27T17:40:10.977000", "db": "NVD", "id": "CVE-2021-37182" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202206-1281" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Vulnerability related to insufficient data integrity verification in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-019921" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202206-1281" } ], "trust": 0.6 } }
var-202208-0610
Vulnerability from variot
Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack. SCALANCE M-800 firmware, SCALANCE S615 firmware, scalance w700 ieee 802.11ax Multiple Siemens products, including firmware, contain vulnerabilities related to limited or unthrottled resource allocation.Service operation interruption (DoS) It may be in a state. The SCALANCE M-800, MUM-800 and S615 and RUGGEDCOM RM1224 industrial routers are used for secure remote access to plants via mobile networks (e.g. GPRS or UMTS) and have integrated security functions for firewalls to prevent unauthorized access, as well as VPN to Secure data transmission. SCALANCE SC-600 devices (SC622-2C, SC632-2C, SC636-2C, SC642-2C, SC646-2C) are used to protect trusted industrial networks from untrusted network attacks. They allow filtering incoming and outgoing network connections in different ways. The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. SCALANCE W-700 products are wireless communication devices based on the IEEE 802.11ax standard. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). A vulnerability has been identified in SCALANCE M-800 / S615 (All versions), SCALANCE W-1700 IEEE 802.11ac family (All versions), SCALANCE W-700 IEEE 802.11ax family (All versions), SCALANCE W-700 IEEE 802.11n family (All versions), SCALANCE XB-200 switch family (All versions), SCALANCE XC-200 switch family (All versions), SCALANCE XF-200BA switch family (All versions), SCALANCE XM-400 Family (All versions), SCALANCE XP-200 switch family (All versions), SCALANCE XR-300WG switch family (All versions), SCALANCE XR-500 Family (All versions)
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202208-0610", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "scalance xc206-2sfp g", "scope": null, "trust": 1.6, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xr552-12m 2hr2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc206-2g poe eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc224-4c g \\", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance w700 ieee 802.11ac", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc206-2sfp g \\", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xb216", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr524-8c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xb205-3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc224", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xb208", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr324-4m poe ts", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr324wg", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr524-8c l3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc206-2sfp g", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc216-4c g eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc216-4c g \\", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr528-6m l3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr324-12m ts", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc-200", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr324-4m poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr528-6m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204-2ba irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xm400", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr-300eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc208", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr500", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc216", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp208 \\", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance w700 ieee 802.11n", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xb213-3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc216eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xm408-8c l3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp216", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp216poe eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr552-12m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xm416-4c l3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc208g \\", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc224-4c g", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr552", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr-300", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc224-4c g eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr328-4c wg", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc206-2g poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc206-2sfp g eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp208poe eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr526-8c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc216-4c g", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xb-200", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xb205-3ld", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc206-2sfp eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp216 \\", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204-2ba dna", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf-200ba", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr528-6m 2hr2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc208eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp208", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xm408-8c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr-300poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr552-12m 2hr2 l3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc208g poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance w700 ieee 802.11ax", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xb213-3ld", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc206-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xm408-4c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xm408-4c l3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr326-2c poe wg", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr552-12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp208eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr324-12m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr524", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp-200", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance s615", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc208g eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr528-6m 2hr2 l3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp216eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr324-4m eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr528", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc208g", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc216-4c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance m-800", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xm416-4c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr526-8c l3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr526", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr-300wg", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xb205-3", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xc206-2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xb-200", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xb216", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance w700 ieee 802.11ax", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xc-200", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xc206-2sfp g eec", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m-800", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xb213-3ld", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xb213-3", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xc206-2g poe eec", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance w700 ieee 802.11n", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance w700 ieee 802.11ac", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xb205-3ld", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance s615", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xc206-2sfp eec", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xb208", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xc206-2g poe", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m-800 s615", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "/" }, { "model": "scalance w-700 ieee 802.11ax family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance w-700 ieee 802.11n family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance w-1700 ieee 802.11ac family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xb-200 switch family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xc-200 switch family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xf-200ba switch family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xm-400 family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xp-200 switch family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xr-300wg switch family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xr-500 family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-56475" }, { "db": "JVNDB", "id": "JVNDB-2022-014932" }, { "db": "NVD", "id": "CVE-2022-36324" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens has reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202208-2714" } ], "trust": 0.6 }, "cve": "CVE-2022-36324", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2022-56475", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2022-36324", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2022-36324", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-36324", "trust": 1.0, "value": "HIGH" }, { "author": "productcert@siemens.com", "id": "CVE-2022-36324", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2022-36324", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2022-56475", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202208-2714", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-56475" }, { "db": "JVNDB", "id": "JVNDB-2022-014932" }, { "db": "CNNVD", "id": "CNNVD-202208-2714" }, { "db": "NVD", "id": "CVE-2022-36324" }, { "db": "NVD", "id": "CVE-2022-36324" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack. SCALANCE M-800 firmware, SCALANCE S615 firmware, scalance w700 ieee 802.11ax Multiple Siemens products, including firmware, contain vulnerabilities related to limited or unthrottled resource allocation.Service operation interruption (DoS) It may be in a state. The SCALANCE M-800, MUM-800 and S615 and RUGGEDCOM RM1224 industrial routers are used for secure remote access to plants via mobile networks (e.g. GPRS or UMTS) and have integrated security functions for firewalls to prevent unauthorized access, as well as VPN to Secure data transmission. SCALANCE SC-600 devices (SC622-2C, SC632-2C, SC636-2C, SC642-2C, SC646-2C) are used to protect trusted industrial networks from untrusted network attacks. They allow filtering incoming and outgoing network connections in different ways. The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. SCALANCE W-700 products are wireless communication devices based on the IEEE 802.11ax standard. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). A vulnerability has been identified in SCALANCE M-800 / S615 (All versions), SCALANCE W-1700 IEEE 802.11ac family (All versions), SCALANCE W-700 IEEE 802.11ax family (All versions), SCALANCE W-700 IEEE 802.11n family (All versions), SCALANCE XB-200 switch family (All versions), SCALANCE XC-200 switch family (All versions), SCALANCE XF-200BA switch family (All versions), SCALANCE XM-400 Family (All versions), SCALANCE XP-200 switch family (All versions), SCALANCE XR-300WG switch family (All versions), SCALANCE XR-500 Family (All versions)", "sources": [ { "db": "NVD", "id": "CVE-2022-36324" }, { "db": "JVNDB", "id": "JVNDB-2022-014932" }, { "db": "CNVD", "id": "CNVD-2022-56475" }, { "db": "VULMON", "id": "CVE-2022-36324" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-36324", "trust": 3.9 }, { "db": "SIEMENS", "id": "SSA-710008", "trust": 3.1 }, { "db": "ICS CERT", "id": "ICSA-22-223-07", "trust": 1.5 }, { "db": "JVN", "id": "JVNVU90767165", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2022-014932", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2022-56475", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2022.4032", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202208-2714", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2022-36324", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-56475" }, { "db": "VULMON", "id": "CVE-2022-36324" }, { "db": "JVNDB", "id": "JVNDB-2022-014932" }, { "db": "CNNVD", "id": "CNNVD-202208-2714" }, { "db": "NVD", "id": "CVE-2022-36324" } ] }, "id": "VAR-202208-0610", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2022-56475" } ], "trust": 1.2363483332142855 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-56475" } ] }, "last_update_date": "2024-08-14T14:17:48.847000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Unknown Vulnerability in Siemens SCALANCE Products", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/343621" }, { "title": "Multiple Siemens SCALANCE Product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=207453" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-56475" }, { "db": "CNNVD", "id": "CNNVD-202208-2714" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-770", "trust": 1.0 }, { "problemtype": "Allocation of resources without limits or throttling (CWE-770) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-014932" }, { "db": "NVD", "id": "CVE-2022-36324" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu90767165/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-36324" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-223-07" }, { "trust": 0.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-710008.html" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2022.4032" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-36324/" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-223-07" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/770.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-223-07" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-56475" }, { "db": "VULMON", "id": "CVE-2022-36324" }, { "db": "JVNDB", "id": "JVNDB-2022-014932" }, { "db": "CNNVD", "id": "CNNVD-202208-2714" }, { "db": "NVD", "id": "CVE-2022-36324" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2022-56475" }, { "db": "VULMON", "id": "CVE-2022-36324" }, { "db": "JVNDB", "id": "JVNDB-2022-014932" }, { "db": "CNNVD", "id": "CNNVD-202208-2714" }, { "db": "NVD", "id": "CVE-2022-36324" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-08-12T00:00:00", "db": "CNVD", "id": "CNVD-2022-56475" }, { "date": "2022-08-10T00:00:00", "db": "VULMON", "id": "CVE-2022-36324" }, { "date": "2023-09-22T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-014932" }, { "date": "2022-08-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202208-2714" }, { "date": "2022-08-10T12:15:12.930000", "db": "NVD", "id": "CVE-2022-36324" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-08-12T00:00:00", "db": "CNVD", "id": "CNVD-2022-56475" }, { "date": "2022-08-10T00:00:00", "db": "VULMON", "id": "CVE-2022-36324" }, { "date": "2023-09-22T08:25:00", "db": "JVNDB", "id": "JVNDB-2022-014932" }, { "date": "2022-09-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202208-2714" }, { "date": "2023-02-23T16:19:42.137000", "db": "NVD", "id": "CVE-2022-36324" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202208-2714" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Vulnerability in limiting or non-slotting resource allocation in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-014932" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202208-2714" } ], "trust": 0.6 } }
var-202208-0611
Vulnerability from variot
Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. SCALANCE M-800 firmware, SCALANCE S615 firmware, SCALANCE SC-600 Multiple Siemens products such as firmware have unspecified vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. SCALANCE M-800, MUM-800 and S615 and RUGGEDCOM RM1224 industrial routers are used for secure remote access to plants via mobile networks (e.g. GPRS or UMTS) and have integrated security functions of firewalls to prevent unauthorized access, as well as VPNs to Secure data transmission. SCALANCE SC-600 devices (SC622-2C, SC632-2C, SC636-2C, SC642-2C, SC646-2C) are used to protect trusted industrial networks from untrusted network attacks. They allow filtering incoming and outgoing network connections in different ways. The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. SCALANCE W-700 products are wireless communication devices based on the IEEE 802.11ax standard. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI).
A command injection vulnerability exists in Siemens SCALANCE products, which results from an affected device failing to properly filter input fields. A vulnerability has been identified in SCALANCE M-800 / S615 (All versions), SCALANCE SC-600 family (All versions < V2.3.1), SCALANCE W-1700 IEEE 802.11ac family (All versions), SCALANCE W-700 IEEE 802.11ax family (All versions), SCALANCE W-700 IEEE 802.11n family (All versions), SCALANCE XB-200 switch family (All versions), SCALANCE XC-200 switch family (All versions), SCALANCE XF-200BA switch family (All versions), SCALANCE XM-400 Family (All versions), SCALANCE XP-200 switch family (All versions), SCALANCE XR-300WG switch family (All versions), SCALANCE XR-500 Family (All versions)
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202208-0611", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "scalance xr552-12m 2hr2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc206-2g poe eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc224-4c g \\", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance w700 ieee 802.11ac", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc206-2sfp g \\", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xb216", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr524-8c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xb205-3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc224", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance sc-600", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3.1" }, { "model": "scalance xb208", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr324-4m poe ts", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr324wg", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr524-8c l3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc206-2sfp g", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc216-4c g eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc216-4c g \\", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr528-6m l3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance sc642-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3.1" }, { "model": "scalance sc632-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3.1" }, { "model": "scalance xr324-12m ts", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc-200", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr324-4m poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr528-6m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204-2ba irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xm400", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr-300eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc208", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr500", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc216", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp208 \\", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance w700 ieee 802.11n", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xb213-3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc216eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xm408-8c l3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp216", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp216poe eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr552-12m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xm416-4c l3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc208g \\", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc224-4c g", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr552", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr-300", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc224-4c g eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr328-4c wg", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc206-2g poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc206-2sfp g eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp208poe eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr526-8c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc216-4c g", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xb-200", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xb205-3ld", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance sc636-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3.1" }, { "model": "scalance xc206-2sfp eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp216 \\", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204-2ba dna", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf-200ba", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr528-6m 2hr2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc208eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp208", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xm408-8c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr-300poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr552-12m 2hr2 l3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc208g poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance w700 ieee 802.11ax", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xb213-3ld", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc206-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xm408-4c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xm408-4c l3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr326-2c poe wg", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr552-12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp208eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr324-12m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr524", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp-200", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance s615", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc208g eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr528-6m 2hr2 l3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp216eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr324-4m eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr528", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance sc622-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3.1" }, { "model": "scalance xc208g", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance sc646-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3.1" }, { "model": "scalance xc216-4c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance m-800", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xm416-4c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr526-8c l3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr526", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr-300wg", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance sc-646-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xb205-3", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc-600", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xc206-2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xb-200", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance w700 ieee 802.11ax", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xb216", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc-622-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xc-200", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m-800", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xb213-3ld", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc-632-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xb213-3", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc-642-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance w700 ieee 802.11ac", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance w700 ieee 802.11n", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xb205-3ld", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc-636-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance s615", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xb208", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m-800 s615", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "/" }, { "model": "scalance sc-600 family", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v2.3.1" }, { "model": "scalance w-700 ieee 802.11ax family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance w-700 ieee 802.11n family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance w-1700 ieee 802.11ac family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xb-200 switch family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xc-200 switch family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xf-200ba switch family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xm-400 family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xp-200 switch family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xr-300wg switch family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xr-500 family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-56476" }, { "db": "JVNDB", "id": "JVNDB-2022-014933" }, { "db": "NVD", "id": "CVE-2022-36323" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens has reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202208-2715" } ], "trust": 0.6 }, "cve": "CVE-2022-36323", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2022-56476", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "productcert@siemens.com", "availabilityImpact": "HIGH", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.3, "id": "CVE-2022-36323", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.2, "id": "CVE-2022-36323", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 9.1, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2022-014933", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "productcert@siemens.com", "id": "CVE-2022-36323", "trust": 1.0, "value": "CRITICAL" }, { "author": "nvd@nist.gov", "id": "CVE-2022-36323", "trust": 1.0, "value": "HIGH" }, { "author": "OTHER", "id": "JVNDB-2022-014933", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2022-56476", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202208-2715", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-56476" }, { "db": "JVNDB", "id": "JVNDB-2022-014933" }, { "db": "CNNVD", "id": "CNNVD-202208-2715" }, { "db": "NVD", "id": "CVE-2022-36323" }, { "db": "NVD", "id": "CVE-2022-36323" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. SCALANCE M-800 firmware, SCALANCE S615 firmware, SCALANCE SC-600 Multiple Siemens products such as firmware have unspecified vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. SCALANCE M-800, MUM-800 and S615 and RUGGEDCOM RM1224 industrial routers are used for secure remote access to plants via mobile networks (e.g. GPRS or UMTS) and have integrated security functions of firewalls to prevent unauthorized access, as well as VPNs to Secure data transmission. SCALANCE SC-600 devices (SC622-2C, SC632-2C, SC636-2C, SC642-2C, SC646-2C) are used to protect trusted industrial networks from untrusted network attacks. They allow filtering incoming and outgoing network connections in different ways. The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. SCALANCE W-700 products are wireless communication devices based on the IEEE 802.11ax standard. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). \n\r\n\r\nA command injection vulnerability exists in Siemens SCALANCE products, which results from an affected device failing to properly filter input fields. A vulnerability has been identified in SCALANCE M-800 / S615 (All versions), SCALANCE SC-600 family (All versions \u003c V2.3.1), SCALANCE W-1700 IEEE 802.11ac family (All versions), SCALANCE W-700 IEEE 802.11ax family (All versions), SCALANCE W-700 IEEE 802.11n family (All versions), SCALANCE XB-200 switch family (All versions), SCALANCE XC-200 switch family (All versions), SCALANCE XF-200BA switch family (All versions), SCALANCE XM-400 Family (All versions), SCALANCE XP-200 switch family (All versions), SCALANCE XR-300WG switch family (All versions), SCALANCE XR-500 Family (All versions)", "sources": [ { "db": "NVD", "id": "CVE-2022-36323" }, { "db": "JVNDB", "id": "JVNDB-2022-014933" }, { "db": "CNVD", "id": "CNVD-2022-56476" }, { "db": "VULMON", "id": "CVE-2022-36323" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-36323", "trust": 3.9 }, { "db": "SIEMENS", "id": "SSA-710008", "trust": 3.1 }, { "db": "ICS CERT", "id": "ICSA-22-223-07", "trust": 1.5 }, { "db": "JVN", "id": "JVNVU90767165", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2022-014933", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2022-56476", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2022.4032", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202208-2715", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2022-36323", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-56476" }, { "db": "VULMON", "id": "CVE-2022-36323" }, { "db": "JVNDB", "id": "JVNDB-2022-014933" }, { "db": "CNNVD", "id": "CNNVD-202208-2715" }, { "db": "NVD", "id": "CVE-2022-36323" } ] }, "id": "VAR-202208-0611", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2022-56476" } ], "trust": 1.2477712656666666 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-56476" } ] }, "last_update_date": "2024-08-14T14:17:45.411000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens SCALANCE product command injection vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/343616" }, { "title": "Siemens SCALANCE Security vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=243185" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-56476" }, { "db": "CNNVD", "id": "CNNVD-202208-2715" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-Other", "trust": 1.0 }, { "problemtype": "CWE-74", "trust": 1.0 }, { "problemtype": "others (CWE-Other) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-014933" }, { "db": "NVD", "id": "CVE-2022-36323" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu90767165/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-36323" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-223-07" }, { "trust": 0.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-710008.html" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2022.4032" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-36323/" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-223-07" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/74.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-223-07" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-56476" }, { "db": "VULMON", "id": "CVE-2022-36323" }, { "db": "JVNDB", "id": "JVNDB-2022-014933" }, { "db": "CNNVD", "id": "CNNVD-202208-2715" }, { "db": "NVD", "id": "CVE-2022-36323" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2022-56476" }, { "db": "VULMON", "id": "CVE-2022-36323" }, { "db": "JVNDB", "id": "JVNDB-2022-014933" }, { "db": "CNNVD", "id": "CNNVD-202208-2715" }, { "db": "NVD", "id": "CVE-2022-36323" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-08-12T00:00:00", "db": "CNVD", "id": "CNVD-2022-56476" }, { "date": "2022-08-10T00:00:00", "db": "VULMON", "id": "CVE-2022-36323" }, { "date": "2023-09-22T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-014933" }, { "date": "2022-08-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202208-2715" }, { "date": "2022-08-10T12:15:12.863000", "db": "NVD", "id": "CVE-2022-36323" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-08-12T00:00:00", "db": "CNVD", "id": "CNVD-2022-56476" }, { "date": "2022-08-10T00:00:00", "db": "VULMON", "id": "CVE-2022-36323" }, { "date": "2023-09-22T08:25:00", "db": "JVNDB", "id": "JVNDB-2022-014933" }, { "date": "2023-06-28T00:00:00", "db": "CNNVD", "id": "CNNVD-202208-2715" }, { "date": "2023-06-27T19:43:45.920000", "db": "NVD", "id": "CVE-2022-36323" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202208-2715" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Vulnerabilities in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-014933" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202208-2715" } ], "trust": 0.6 } }
var-202208-0612
Vulnerability from variot
Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS. SCALANCE M-800 firmware, SCALANCE S615 firmware, SCALANCE SC-600 Multiple Siemens products such as firmware have unspecified vulnerabilities.Information may be obtained and information may be tampered with. SCALANCE M-800, MUM-800 and S615 and RUGGEDCOM RM1224 industrial routers are used for secure remote access to plants via mobile networks (e.g. GPRS or UMTS) and have integrated security functions of firewalls to prevent unauthorized access, as well as VPNs to Secure data transmission. SCALANCE SC-600 devices (SC622-2C, SC632-2C, SC636-2C, SC642-2C, SC646-2C) are used to protect trusted industrial networks from untrusted network attacks. They allow filtering incoming and outgoing network connections in different ways. The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. SCALANCE W-700 products are wireless communication devices based on the IEEE 802.11ax standard. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). A vulnerability has been identified in SCALANCE M-800 / S615 (All versions), SCALANCE SC-600 family (All versions < V2.3.1), SCALANCE W-1700 IEEE 802.11ac family (All versions), SCALANCE W-700 IEEE 802.11ax family (All versions), SCALANCE W-700 IEEE 802.11n family (All versions), SCALANCE XB-200 switch family (All versions), SCALANCE XC-200 switch family (All versions), SCALANCE XF-200BA switch family (All versions), SCALANCE XM-400 Family (All versions), SCALANCE XP-200 switch family (All versions), SCALANCE XR-300WG switch family (All versions), SCALANCE XR-500 Family (All versions)
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202208-0612", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "scalance xr552-12m 2hr2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc206-2g poe eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc224-4c g \\", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance w700 ieee 802.11ac", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc206-2sfp g \\", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xb216", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr524-8c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xb205-3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc224", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance sc-600", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3.1" }, { "model": "scalance xb208", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr324-4m poe ts", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr324wg", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr524-8c l3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc206-2sfp g", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc216-4c g eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc216-4c g \\", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr528-6m l3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance sc642-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3.1" }, { "model": "scalance sc632-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3.1" }, { "model": "scalance xr324-12m ts", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc-200", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr324-4m poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr528-6m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204-2ba irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xm400", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr-300eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc208", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr500", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc216", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp208 \\", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance w700 ieee 802.11n", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xb213-3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc216eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xm408-8c l3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp216", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp216poe eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr552-12m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xm416-4c l3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc208g \\", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc224-4c g", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr552", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr-300", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc224-4c g eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr328-4c wg", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc206-2g poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc206-2sfp g eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp208poe eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr526-8c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc216-4c g", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xb-200", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xb205-3ld", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance sc636-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3.1" }, { "model": "scalance xc206-2sfp eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp216 \\", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204-2ba dna", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf-200ba", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr528-6m 2hr2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc208eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp208", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xm408-8c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr-300poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr552-12m 2hr2 l3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc208g poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance w700 ieee 802.11ax", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xb213-3ld", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc206-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xm408-4c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xm408-4c l3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr326-2c poe wg", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr552-12", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp208eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr324-12m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr524", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp-200", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance s615", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xc208g eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr528-6m 2hr2 l3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp216eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr324-4m eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr528", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance sc622-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3.1" }, { "model": "scalance xc208g", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance sc646-2c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3.1" }, { "model": "scalance xc216-4c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance m-800", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xm416-4c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr526-8c l3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr526", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr-300wg", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance sc-646-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xb205-3", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc-600", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xc206-2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xb-200", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance w700 ieee 802.11ax", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xb216", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc-622-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xc-200", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m-800", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xb213-3ld", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc-632-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xb213-3", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc-642-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance w700 ieee 802.11ac", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance w700 ieee 802.11n", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xb205-3ld", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance sc-636-2c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance s615", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xb208", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m-800 s615", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "/" }, { "model": "scalance sc-600 family", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v2.3.1" }, { "model": "scalance w-700 ieee 802.11ax family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance w-700 ieee 802.11n family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance w-1700 ieee 802.11ac family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xb-200 switch family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xc-200 switch family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xf-200ba switch family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xm-400 family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xp-200 switch family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xr-300wg switch family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xr-500 family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-56474" }, { "db": "JVNDB", "id": "JVNDB-2022-014931" }, { "db": "NVD", "id": "CVE-2022-36325" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens has reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202208-2711" } ], "trust": 0.6 }, "cve": "CVE-2022-36325", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2022-56474", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 1.7, "id": "CVE-2022-36325", "impactScore": 2.7, "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "productcert@siemens.com", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "id": "CVE-2022-36325", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 4.8, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "CVE-2022-36325", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "High", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-36325", "trust": 1.0, "value": "MEDIUM" }, { "author": "productcert@siemens.com", "id": "CVE-2022-36325", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2022-36325", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2022-56474", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202208-2711", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-56474" }, { "db": "JVNDB", "id": "JVNDB-2022-014931" }, { "db": "CNNVD", "id": "CNNVD-202208-2711" }, { "db": "NVD", "id": "CVE-2022-36325" }, { "db": "NVD", "id": "CVE-2022-36325" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS. SCALANCE M-800 firmware, SCALANCE S615 firmware, SCALANCE SC-600 Multiple Siemens products such as firmware have unspecified vulnerabilities.Information may be obtained and information may be tampered with. SCALANCE M-800, MUM-800 and S615 and RUGGEDCOM RM1224 industrial routers are used for secure remote access to plants via mobile networks (e.g. GPRS or UMTS) and have integrated security functions of firewalls to prevent unauthorized access, as well as VPNs to Secure data transmission. SCALANCE SC-600 devices (SC622-2C, SC632-2C, SC636-2C, SC642-2C, SC646-2C) are used to protect trusted industrial networks from untrusted network attacks. They allow filtering incoming and outgoing network connections in different ways. The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. SCALANCE W-700 products are wireless communication devices based on the IEEE 802.11ax standard. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). A vulnerability has been identified in SCALANCE M-800 / S615 (All versions), SCALANCE SC-600 family (All versions \u003c V2.3.1), SCALANCE W-1700 IEEE 802.11ac family (All versions), SCALANCE W-700 IEEE 802.11ax family (All versions), SCALANCE W-700 IEEE 802.11n family (All versions), SCALANCE XB-200 switch family (All versions), SCALANCE XC-200 switch family (All versions), SCALANCE XF-200BA switch family (All versions), SCALANCE XM-400 Family (All versions), SCALANCE XP-200 switch family (All versions), SCALANCE XR-300WG switch family (All versions), SCALANCE XR-500 Family (All versions)", "sources": [ { "db": "NVD", "id": "CVE-2022-36325" }, { "db": "JVNDB", "id": "JVNDB-2022-014931" }, { "db": "CNVD", "id": "CNVD-2022-56474" }, { "db": "VULMON", "id": "CVE-2022-36325" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-36325", "trust": 3.9 }, { "db": "SIEMENS", "id": "SSA-710008", "trust": 3.1 }, { "db": "ICS CERT", "id": "ICSA-22-223-07", "trust": 1.5 }, { "db": "JVN", "id": "JVNVU90767165", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2022-014931", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2022-56474", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2022.4032", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202208-2711", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2022-36325", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-56474" }, { "db": "VULMON", "id": "CVE-2022-36325" }, { "db": "JVNDB", "id": "JVNDB-2022-014931" }, { "db": "CNNVD", "id": "CNNVD-202208-2711" }, { "db": "NVD", "id": "CVE-2022-36325" } ] }, "id": "VAR-202208-0612", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2022-56474" } ], "trust": 1.2477712656666666 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-56474" } ] }, "last_update_date": "2024-08-14T14:17:48.938000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Unknown Vulnerability in Siemens SCALANCE Products (CNVD-2022-56474)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/343626" }, { "title": "Siemens SCALANCE Security vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=243184" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-56474" }, { "db": "CNNVD", "id": "CNNVD-202208-2711" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-80", "trust": 1.0 }, { "problemtype": "NVD-CWE-Other", "trust": 1.0 }, { "problemtype": "others (CWE-Other) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-014931" }, { "db": "NVD", "id": "CVE-2022-36325" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu90767165/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-36325" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-223-07" }, { "trust": 0.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-710008.html" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-36325/" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2022.4032" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-223-07" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/80.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-223-07" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-56474" }, { "db": "VULMON", "id": "CVE-2022-36325" }, { "db": "JVNDB", "id": "JVNDB-2022-014931" }, { "db": "CNNVD", "id": "CNNVD-202208-2711" }, { "db": "NVD", "id": "CVE-2022-36325" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2022-56474" }, { "db": "VULMON", "id": "CVE-2022-36325" }, { "db": "JVNDB", "id": "JVNDB-2022-014931" }, { "db": "CNNVD", "id": "CNNVD-202208-2711" }, { "db": "NVD", "id": "CVE-2022-36325" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-08-12T00:00:00", "db": "CNVD", "id": "CNVD-2022-56474" }, { "date": "2022-08-10T00:00:00", "db": "VULMON", "id": "CVE-2022-36325" }, { "date": "2023-09-22T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-014931" }, { "date": "2022-08-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202208-2711" }, { "date": "2022-08-10T12:15:12.997000", "db": "NVD", "id": "CVE-2022-36325" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-08-12T00:00:00", "db": "CNVD", "id": "CNVD-2022-56474" }, { "date": "2022-08-10T00:00:00", "db": "VULMON", "id": "CVE-2022-36325" }, { "date": "2023-09-22T08:25:00", "db": "JVNDB", "id": "JVNDB-2022-014931" }, { "date": "2023-06-28T00:00:00", "db": "CNNVD", "id": "CNNVD-202208-2711" }, { "date": "2023-06-27T19:51:47.307000", "db": "NVD", "id": "CVE-2022-36325" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202208-2711" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Vulnerabilities in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-014931" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202208-2711" } ], "trust": 0.6 } }