All the vulnerabilites related to Siemens - SCALANCE XF204 IRT
var-202104-1127
Vulnerability from variot
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT PRO (All versions < 5.5.1), SCALANCE X202-2 IRT (All versions < 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions < 5.5.1), SCALANCE X202-2P IRT PRO (All versions < 5.5.1), SCALANCE X204 IRT (All versions < 5.5.1), SCALANCE X204 IRT PRO (All versions < 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2FM (All versions < V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2LD TS (All versions < V5.2.5), SCALANCE X204-2TS (All versions < V5.2.5), SCALANCE X206-1 (All versions < V5.2.5), SCALANCE X206-1LD (All versions < V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X208PRO (All versions < V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X212-2LD (All versions < V5.2.5), SCALANCE X216 (All versions < V5.2.5), SCALANCE X224 (All versions < V5.2.5), SCALANCE XF201-3P IRT (All versions < 5.5.1), SCALANCE XF202-2P IRT (All versions < 5.5.1), SCALANCE XF204 (All versions < V5.2.5), SCALANCE XF204 IRT (All versions < 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE XF204-2BA IRT (All versions < 5.5.1), SCALANCE XF206-1 (All versions < V5.2.5), SCALANCE XF208 (All versions < V5.2.5). Incorrect processing of POST requests in the webserver may result in write out of bounds in heap. An attacker might leverage this to cause denial-of-service on the device and potentially remotely execute code. Siemens SCALANCE X switches are used to connect industrial components, such as programmable logic controllers (PLC) or human machine interfaces (HMI).
The Siemens SCALANCE X-200 Web server has a heap buffer overflow vulnerability. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202104-1127", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "scalance x200-4p irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x201-3p irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x201-3p irt pro", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x202-2p irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x202-2p irt pro", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance xf201-3p irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance xf202-2p irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance xf204 irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance xf204-2ba irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x202-2 irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x204 irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x204 irt pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x216", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x212-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x208pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x206-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2ts", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2ld ts", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf204", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x208", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf206-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf208", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2ld", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2fm", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x212-2ld", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf204-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x206-1ld", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x224", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance irt", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x202-2\u003c5.5.1" }, { "model": "scalance irt", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x204\u003c5.5.1" }, { "model": "scalance irt pro", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x204\u003c5.5.1" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x204-2" }, { "model": "scalance x204-2fm", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xf206-1", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xf208", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance x204-2ld", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance x204-2ld ts", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance x204-2ts", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x206-1" }, { "model": "scalance x206-1ld", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x208" }, { "model": "scalance x208pro", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x212-2" }, { "model": "scalance x212-2ld", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x216" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x224" }, { "model": "scalance xf204", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-28700" }, { "db": "NVD", "id": "CVE-2021-25668" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-988" } ], "trust": 0.6 }, "cve": "CVE-2021-25668", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2021-25668", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.1, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2021-28700", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-25668", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-25668", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2021-28700", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202104-988", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-25668", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-28700" }, { "db": "VULMON", "id": "CVE-2021-25668" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202104-988" }, { "db": "NVD", "id": "CVE-2021-25668" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c 5.5.1), SCALANCE X201-3P IRT (All versions \u003c 5.5.1), SCALANCE X201-3P IRT PRO (All versions \u003c 5.5.1), SCALANCE X202-2 IRT (All versions \u003c 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions \u003c 5.5.1), SCALANCE X202-2P IRT PRO (All versions \u003c 5.5.1), SCALANCE X204 IRT (All versions \u003c 5.5.1), SCALANCE X204 IRT PRO (All versions \u003c 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X204-2FM (All versions \u003c V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X204-2LD TS (All versions \u003c V5.2.5), SCALANCE X204-2TS (All versions \u003c V5.2.5), SCALANCE X206-1 (All versions \u003c V5.2.5), SCALANCE X206-1LD (All versions \u003c V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X208PRO (All versions \u003c V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X212-2LD (All versions \u003c V5.2.5), SCALANCE X216 (All versions \u003c V5.2.5), SCALANCE X224 (All versions \u003c V5.2.5), SCALANCE XF201-3P IRT (All versions \u003c 5.5.1), SCALANCE XF202-2P IRT (All versions \u003c 5.5.1), SCALANCE XF204 (All versions \u003c V5.2.5), SCALANCE XF204 IRT (All versions \u003c 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE XF204-2BA IRT (All versions \u003c 5.5.1), SCALANCE XF206-1 (All versions \u003c V5.2.5), SCALANCE XF208 (All versions \u003c V5.2.5). Incorrect processing of POST requests in the webserver may result in write out of bounds in heap. An attacker might leverage this to cause denial-of-service on the device and potentially remotely execute code. Siemens SCALANCE X switches are used to connect industrial components, such as programmable logic controllers (PLC) or human machine interfaces (HMI). \n\r\n\r\nThe Siemens SCALANCE X-200 Web server has a heap buffer overflow vulnerability. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements", "sources": [ { "db": "NVD", "id": "CVE-2021-25668" }, { "db": "CNVD", "id": "CNVD-2021-28700" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULMON", "id": "CVE-2021-25668" } ], "trust": 2.07 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "SIEMENS", "id": "SSA-187092", "trust": 2.3 }, { "db": "NVD", "id": "CVE-2021-25668", "trust": 2.3 }, { "db": "CNVD", "id": "CNVD-2021-28700", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021041413", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2021.1243", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-21-103-07", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-988", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-25668", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-28700" }, { "db": "VULMON", "id": "CVE-2021-25668" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202104-988" }, { "db": "NVD", "id": "CVE-2021-25668" } ] }, "id": "VAR-202104-1127", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-28700" } ], "trust": 1.1032214615384615 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-28700" } ] }, "last_update_date": "2024-11-23T19:52:37.390000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens SCALANCE X-200 Web Server Heap Buffer Overflow Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/258416" }, { "title": "Siemens Web Server Buffer error vulnerability fix", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=151765" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=00529a77c6bdb45e00924c587b6c52a5" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-28700" }, { "db": "VULMON", "id": "CVE-2021-25668" }, { "db": "CNNVD", "id": "CNNVD-202104-988" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-122", "trust": 1.0 }, { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2021-25668" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-187092.pdf" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041413" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2021.1243" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-07" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-25668" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/122.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://cert-portal.siemens.com/productcert/txt/ssa-187092.txt" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-28700" }, { "db": "VULMON", "id": "CVE-2021-25668" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202104-988" }, { "db": "NVD", "id": "CVE-2021-25668" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-28700" }, { "db": "VULMON", "id": "CVE-2021-25668" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202104-988" }, { "db": "NVD", "id": "CVE-2021-25668" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-15T00:00:00", "db": "CNVD", "id": "CNVD-2021-28700" }, { "date": "2021-04-22T00:00:00", "db": "VULMON", "id": "CVE-2021-25668" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-988" }, { "date": "2021-04-22T21:15:10.110000", "db": "NVD", "id": "CVE-2021-25668" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-15T00:00:00", "db": "CNVD", "id": "CNVD-2021-28700" }, { "date": "2021-09-14T00:00:00", "db": "VULMON", "id": "CVE-2021-25668" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-09-15T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-988" }, { "date": "2024-11-21T05:55:15.517000", "db": "NVD", "id": "CVE-2021-25668" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-988" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens SCALANCE X-200 Web Server Heap Buffer Overflow Vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2021-28700" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-975" } ], "trust": 0.6 } }
var-202104-1128
Vulnerability from variot
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT PRO (All versions < 5.5.1), SCALANCE X202-2 IRT (All versions < 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions < 5.5.1), SCALANCE X202-2P IRT PRO (All versions < 5.5.1), SCALANCE X204 IRT (All versions < 5.5.1), SCALANCE X204 IRT PRO (All versions < 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2FM (All versions < V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2LD TS (All versions < V5.2.5), SCALANCE X204-2TS (All versions < V5.2.5), SCALANCE X206-1 (All versions < V5.2.5), SCALANCE X206-1LD (All versions < V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X208PRO (All versions < V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X212-2LD (All versions < V5.2.5), SCALANCE X216 (All versions < V5.2.5), SCALANCE X224 (All versions < V5.2.5), SCALANCE XF201-3P IRT (All versions < 5.5.1), SCALANCE XF202-2P IRT (All versions < 5.5.1), SCALANCE XF204 (All versions < V5.2.5), SCALANCE XF204 IRT (All versions < 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE XF204-2BA IRT (All versions < 5.5.1), SCALANCE XF206-1 (All versions < V5.2.5), SCALANCE XF208 (All versions < V5.2.5). Incorrect processing of POST requests in the web server may write out of bounds in stack. An attacker might leverage this to denial-of-service of the device or remote code execution. Siemens SCALANCE X switches are used to connect industrial components, such as programmable logic controllers (PLC) or human machine interfaces (HMI).
The Siemens SCALANCE X-200 Web server has a stack buffer overflow vulnerability. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202104-1128", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "scalance x200-4p irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x201-3p irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x201-3p irt pro", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x202-2p irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x202-2p irt pro", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance xf201-3p irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance xf202-2p irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance xf204 irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance xf204-2ba irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x202-2 irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x204 irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x204 irt pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x216", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x212-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x208pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x206-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2ts", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2ld ts", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf204", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x208", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf206-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf208", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2ld", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2fm", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x212-2ld", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf204-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x206-1ld", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x224", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance irt", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x202-2\u003c5.5.1" }, { "model": "scalance irt", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x204\u003c5.5.1" }, { "model": "scalance irt pro", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x204\u003c5.5.1" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x204-2" }, { "model": "scalance xf206-1", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xf208", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance x204-2ld", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance x204-2ld ts", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance x204-2ts", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x206-1" }, { "model": "scalance x206-1ld", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x208" }, { "model": "scalance x208pro", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x212-2" }, { "model": "scalance x212-2ld", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x216" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x224" }, { "model": "scalance xf204", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-28699" }, { "db": "NVD", "id": "CVE-2021-25669" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-984" } ], "trust": 0.6 }, "cve": "CVE-2021-25669", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2021-25669", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.1, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2021-28699", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-25669", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-25669", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2021-28699", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202104-984", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-25669", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-28699" }, { "db": "VULMON", "id": "CVE-2021-25669" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202104-984" }, { "db": "NVD", "id": "CVE-2021-25669" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c 5.5.1), SCALANCE X201-3P IRT (All versions \u003c 5.5.1), SCALANCE X201-3P IRT PRO (All versions \u003c 5.5.1), SCALANCE X202-2 IRT (All versions \u003c 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions \u003c 5.5.1), SCALANCE X202-2P IRT PRO (All versions \u003c 5.5.1), SCALANCE X204 IRT (All versions \u003c 5.5.1), SCALANCE X204 IRT PRO (All versions \u003c 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X204-2FM (All versions \u003c V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X204-2LD TS (All versions \u003c V5.2.5), SCALANCE X204-2TS (All versions \u003c V5.2.5), SCALANCE X206-1 (All versions \u003c V5.2.5), SCALANCE X206-1LD (All versions \u003c V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X208PRO (All versions \u003c V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X212-2LD (All versions \u003c V5.2.5), SCALANCE X216 (All versions \u003c V5.2.5), SCALANCE X224 (All versions \u003c V5.2.5), SCALANCE XF201-3P IRT (All versions \u003c 5.5.1), SCALANCE XF202-2P IRT (All versions \u003c 5.5.1), SCALANCE XF204 (All versions \u003c V5.2.5), SCALANCE XF204 IRT (All versions \u003c 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE XF204-2BA IRT (All versions \u003c 5.5.1), SCALANCE XF206-1 (All versions \u003c V5.2.5), SCALANCE XF208 (All versions \u003c V5.2.5). Incorrect processing of POST requests in the web server may write out of bounds in stack. An attacker might leverage this to denial-of-service of the device or remote code execution. Siemens SCALANCE X switches are used to connect industrial components, such as programmable logic controllers (PLC) or human machine interfaces (HMI). \n\r\n\r\nThe Siemens SCALANCE X-200 Web server has a stack buffer overflow vulnerability. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements", "sources": [ { "db": "NVD", "id": "CVE-2021-25669" }, { "db": "CNVD", "id": "CNVD-2021-28699" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULMON", "id": "CVE-2021-25669" } ], "trust": 2.07 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "SIEMENS", "id": "SSA-187092", "trust": 2.3 }, { "db": "NVD", "id": "CVE-2021-25669", "trust": 2.3 }, { "db": "CNVD", "id": "CNVD-2021-28699", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021041413", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2021.1243", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-21-103-07", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-984", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-25669", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-28699" }, { "db": "VULMON", "id": "CVE-2021-25669" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202104-984" }, { "db": "NVD", "id": "CVE-2021-25669" } ] }, "id": "VAR-202104-1128", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-28699" } ], "trust": 1.1032214615384615 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-28699" } ] }, "last_update_date": "2024-11-23T19:58:16.905000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens SCALANCE X-200 Web Server Stack Buffer Overflow Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/258421" }, { "title": "Siemens Web Server Buffer error vulnerability fix", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=151764" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=00529a77c6bdb45e00924c587b6c52a5" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-28699" }, { "db": "VULMON", "id": "CVE-2021-25669" }, { "db": "CNNVD", "id": "CNNVD-202104-984" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-121", "trust": 1.0 }, { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2021-25669" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-187092.pdf" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041413" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2021.1243" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-07" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-25669" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/787.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://cert-portal.siemens.com/productcert/txt/ssa-187092.txt" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-28699" }, { "db": "VULMON", "id": "CVE-2021-25669" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202104-984" }, { "db": "NVD", "id": "CVE-2021-25669" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-28699" }, { "db": "VULMON", "id": "CVE-2021-25669" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202104-984" }, { "db": "NVD", "id": "CVE-2021-25669" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-15T00:00:00", "db": "CNVD", "id": "CNVD-2021-28699" }, { "date": "2021-04-22T00:00:00", "db": "VULMON", "id": "CVE-2021-25669" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-984" }, { "date": "2021-04-22T21:15:10.143000", "db": "NVD", "id": "CVE-2021-25669" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-15T00:00:00", "db": "CNVD", "id": "CNVD-2021-28699" }, { "date": "2021-04-30T00:00:00", "db": "VULMON", "id": "CVE-2021-25669" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-09-15T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-984" }, { "date": "2024-11-21T05:55:15.703000", "db": "NVD", "id": "CVE-2021-25669" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-984" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens SCALANCE X-200 Web Server Stack Buffer Overflow Vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2021-28699" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-975" } ], "trust": 0.6 } }
var-202107-1608
Vulnerability from variot
Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device. Multiple Siemens products contain vulnerabilities in resource allocation without restrictions or throttling.Service operation interruption (DoS) It may be in a state. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements. Siemens SCALANCE S602是德国西门子(Siemens)公司的一款工业安全设备. Siemens多款产品 存在安全漏洞,该漏洞允许攻击者执行拒绝服务攻击。以下产品和版本受到影响:Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions), RUGGEDCOM RM1224 (All Versions < 6.4), SCALANCE M-800 (All Versions < 6.4), SCALANCE S615 (All Versions < 6.4), SCALANCE W1700 IEEE 802.11ac (All versions), SCALANCE W700 IEEE 802.11n (All versions), SCALANCE X200-4 P IRT (All Versions < V5.5.0), SCALANCE X201-3P IRT (All Versions < V5.5.0), SCALANCE X201-3P IRT PRO (All Versions < V5.5.0), SCALANCE X202-2 IRT (All Versions < V5.5.0), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All Versions < V5.5.0), SCALANCE X202-2P IRT PRO (All Versions < V5.5.0), SCALANCE X204 IRT (All Versions < V5.5.0), SCALANCE X204 IRT PRO (All Versions < V5.5.0), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions), SCALANCE X204-2FM (All versions), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions), SCALANCE X204-2LD TS (All versions), SCALANCE X204-2TS (All versions), SCALANCE X206-1 (All versions), SCALANCE X206-1LD (incl. SIPLUS NET variant) (All versions), SCALANCE X208 (incl. SIPLUS NET variant) (All versions), SCALANCE X208PRO (All versions), SCALANCE X212-2 (All versions), SCALANCE X212-2LD (All versions), SCALANCE X216 (All versions), SCALANCE X224 (All versions), SCALANCE X302-7EEC (All versions), SCALANCE X304-2FE (All versions), SCALANCE X306-1LDFE (All versions), SCALANCE X307-2EEC (All versions), SCALANCE X307-3 (All versions), SCALANCE X307-3LD (All versions), SCALANCE X308-2 (incl. SIPLUS NET variant) (All versions), SCALANCE X308-2LD (All versions), SCALANCE X308-2LH (All versions), SCALANCE X308-2LH+ (All versions), SCALANCE X308-2M (All versions), SCALANCE X308-2M POE (All versions), SCALANCE X308-2M TS (All versions), SCALANCE X310 (All versions), SCALANCE X310FE (All versions), SCALANCE X320-1FE (All versions), SCALANCE X320-3LDFE (All versions), SCALANCE XB-200 (All versions), SCALANCE XC-200 (All versions), SCALANCE XF-200BA (All versions), SCALANCE XF201-3P IRT (All Versions < V5.5.0), SCALANCE XF202-2P IRT (All Versions < V5.5.0), SCALANCE XF204 (All versions), SCALANCE XF204 IRT (All Versions < V5.5.0), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions), SCALANCE XF204-2BA IRT (All Versions < V5.5.0), SCALANCE XF206-1 (All versions), SCALANCE XF208 (All versions), SCALANCE XM400 (All versions < V6.3.1), SCALANCE XP-200 (All versions), SCALANCE XR-300WG (All versions), SCALANCE XR324-12M (All versions), SCALANCE XR324-12M TS (All versions), SCALANCE XR324-4M EEC (All versions), SCALANCE XR324-4M POE (All versions), SCALANCE XR324-4M POE TS (All versions), SCALANCE XR500 (All versions < V6.3.1), SIMATIC CFU PA (All versions), SIMATIC IE/PB-LINK V3 (All versions), SIMATIC MV500 family (All versions < V3.0), SIMATIC NET CM 1542-1 (All versions), SIMATIC NET CP1616/CP1604 (All Versions >= V2.7), SIMATIC NET CP1626 (All versions), SIMATIC NET DK-16xx PN IO (All Versions >= V2.7), SIMATIC PROFINET Driver (All versions), SIMATIC Power Line Booster PLB, Base Module (MLFB: 6ES7972-5AA10-0AB0) (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All Versions < V4.5), SIMOCODE proV Ethernet/IP (All versions < V1.1.3), SIMOCODE proV PROFINET (All versions < V2.1.3), SOFTNET-IE PNIO (All versions)
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202107-1608", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "scalance x206-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x201-3p irt pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "softnet-ie pnio", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x310fe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic net cp1604", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "2.7" }, { "model": "scalance xr324-12m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x306-1ldfe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x304-2fe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simocode prov profinet", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.1.3" }, { "model": "simatic net cm 1542-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance w1700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x206-1ld", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x308-2m poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x202-2p irt pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x310", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr324-4m poe ts", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simocode prov ethernet\\/ip", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.1.3" }, { "model": "scalance x204 irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "dk standard ethernet controller evaluation kit", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x308-2lh\\+", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204-2ba irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x308-2m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x204-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf204", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x307-3ld", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr324-4m poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf206-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204 irt pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "simatic ie\\/pb-link v3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x308-2lh", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x308-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x307-2eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "ek-ertec 200 evaulation kit", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x320-1fe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr324-12m ts", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic power line booster plb", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic profinet driver", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3" }, { "model": "scalance x201-3p irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x208", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance m-800", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.4" }, { "model": "scalance x308-2ld", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic mv500", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "scalance x212-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xb-200", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.3" }, { "model": "scalance xf-200ba", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.3" }, { "model": "scalance x208pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2ts", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x308-2m ts", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204 irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance w700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic net dk-16xx pn io", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "2.7" }, { "model": "scalance xf202-2p irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x307-3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-1200", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.5" }, { "model": "simatic cfu pa", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr500", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.3.1" }, { "model": "scalance x302-7eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "ek-ertec 200p evaluation kit", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "scalance xf201-3p irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance xc-200", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.3" }, { "model": "scalance x200-4 p irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x204-2ld ts", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2ld", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xr-300wg", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.3" }, { "model": "scalance xp-200", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.3" }, { "model": "scalance x320-3ldfe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance s615", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.4" }, { "model": "scalance x224", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "simatic net cp1626", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr324-4m eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf208", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x216", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x212-2ld", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "simatic net cp1616", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "2.7" }, { "model": "scalance xm400", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.3.1" }, { "model": "ruggedcom rm1224", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.4" }, { "model": "scalance x202-2 irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x204-2fm", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x200-4p irt", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "dk standard ethernet controller evaluation kit", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance w1700", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance s615", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "ek-ertec 200p evaluation kit", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x201-3p irt", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "ek-ertec 200 evaluation kit", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance w700", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m-800", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "ruggedcom rm1224", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-010133" }, { "db": "NVD", "id": "CVE-2020-28400" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported this vulnerability to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202107-901" } ], "trust": 0.6 }, "cve": "CVE-2020-28400", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2020-28400", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2020-28400", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2020-28400", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-28400", "trust": 1.0, "value": "HIGH" }, { "author": "productcert@siemens.com", "id": "CVE-2020-28400", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2020-28400", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202107-901", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-010133" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-901" }, { "db": "NVD", "id": "CVE-2020-28400" }, { "db": "NVD", "id": "CVE-2020-28400" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device. Multiple Siemens products contain vulnerabilities in resource allocation without restrictions or throttling.Service operation interruption (DoS) It may be in a state. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements. Siemens SCALANCE S602\u662f\u5fb7\u56fd\u897f\u95e8\u5b50\uff08Siemens\uff09\u516c\u53f8\u7684\u4e00\u6b3e\u5de5\u4e1a\u5b89\u5168\u8bbe\u5907. \nSiemens\u591a\u6b3e\u4ea7\u54c1 \u5b58\u5728\u5b89\u5168\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u5141\u8bb8\u653b\u51fb\u8005\u6267\u884c\u62d2\u7edd\u670d\u52a1\u653b\u51fb\u3002\u4ee5\u4e0b\u4ea7\u54c1\u548c\u7248\u672c\u53d7\u5230\u5f71\u54cd\uff1aDevelopment/Evaluation Kits for PROFINET IO\uff1a DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO\uff1a EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO\uff1a EK-ERTEC 200P (All versions), RUGGEDCOM RM1224 (All Versions \uff1c 6.4), SCALANCE M-800 (All Versions \uff1c 6.4), SCALANCE S615 (All Versions \uff1c 6.4), SCALANCE W1700 IEEE 802.11ac (All versions), SCALANCE W700 IEEE 802.11n (All versions), SCALANCE X200-4 P IRT (All Versions \uff1c V5.5.0), SCALANCE X201-3P IRT (All Versions \uff1c V5.5.0), SCALANCE X201-3P IRT PRO (All Versions \uff1c V5.5.0), SCALANCE X202-2 IRT (All Versions \uff1c V5.5.0), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All Versions \uff1c V5.5.0), SCALANCE X202-2P IRT PRO (All Versions \uff1c V5.5.0), SCALANCE X204 IRT (All Versions \uff1c V5.5.0), SCALANCE X204 IRT PRO (All Versions \uff1c V5.5.0), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions), SCALANCE X204-2FM (All versions), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions), SCALANCE X204-2LD TS (All versions), SCALANCE X204-2TS (All versions), SCALANCE X206-1 (All versions), SCALANCE X206-1LD (incl. SIPLUS NET variant) (All versions), SCALANCE X208 (incl. SIPLUS NET variant) (All versions), SCALANCE X208PRO (All versions), SCALANCE X212-2 (All versions), SCALANCE X212-2LD (All versions), SCALANCE X216 (All versions), SCALANCE X224 (All versions), SCALANCE X302-7EEC (All versions), SCALANCE X304-2FE (All versions), SCALANCE X306-1LDFE (All versions), SCALANCE X307-2EEC (All versions), SCALANCE X307-3 (All versions), SCALANCE X307-3LD (All versions), SCALANCE X308-2 (incl. SIPLUS NET variant) (All versions), SCALANCE X308-2LD (All versions), SCALANCE X308-2LH (All versions), SCALANCE X308-2LH+ (All versions), SCALANCE X308-2M (All versions), SCALANCE X308-2M POE (All versions), SCALANCE X308-2M TS (All versions), SCALANCE X310 (All versions), SCALANCE X310FE (All versions), SCALANCE X320-1FE (All versions), SCALANCE X320-3LDFE (All versions), SCALANCE XB-200 (All versions), SCALANCE XC-200 (All versions), SCALANCE XF-200BA (All versions), SCALANCE XF201-3P IRT (All Versions \uff1c V5.5.0), SCALANCE XF202-2P IRT (All Versions \uff1c V5.5.0), SCALANCE XF204 (All versions), SCALANCE XF204 IRT (All Versions \uff1c V5.5.0), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions), SCALANCE XF204-2BA IRT (All Versions \uff1c V5.5.0), SCALANCE XF206-1 (All versions), SCALANCE XF208 (All versions), SCALANCE XM400 (All versions \uff1c V6.3.1), SCALANCE XP-200 (All versions), SCALANCE XR-300WG (All versions), SCALANCE XR324-12M (All versions), SCALANCE XR324-12M TS (All versions), SCALANCE XR324-4M EEC (All versions), SCALANCE XR324-4M POE (All versions), SCALANCE XR324-4M POE TS (All versions), SCALANCE XR500 (All versions \uff1c V6.3.1), SIMATIC CFU PA (All versions), SIMATIC IE/PB-LINK V3 (All versions), SIMATIC MV500 family (All versions \uff1c V3.0), SIMATIC NET CM 1542-1 (All versions), SIMATIC NET CP1616/CP1604 (All Versions \uff1e= V2.7), SIMATIC NET CP1626 (All versions), SIMATIC NET DK-16xx PN IO (All Versions \uff1e= V2.7), SIMATIC PROFINET Driver (All versions), SIMATIC Power Line Booster PLB, Base Module (MLFB\uff1a 6ES7972-5AA10-0AB0) (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All Versions \uff1c V4.5), SIMOCODE proV Ethernet/IP (All versions \uff1c V1.1.3), SIMOCODE proV PROFINET (All versions \uff1c V2.1.3), SOFTNET-IE PNIO (All versions)", "sources": [ { "db": "NVD", "id": "CVE-2020-28400" }, { "db": "JVNDB", "id": "JVNDB-2021-010133" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-901" }, { "db": "VULMON", "id": "CVE-2020-28400" } ], "trust": 2.79 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-28400", "trust": 3.3 }, { "db": "ICS CERT", "id": "ICSA-21-194-03", "trust": 2.4 }, { "db": "SIEMENS", "id": "SSA-599968", "trust": 1.7 }, { "db": "JVNDB", "id": "JVNDB-2021-010133", "trust": 0.8 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2021.2401", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021071416", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202107-901", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2020-28400", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2020-28400" }, { "db": "JVNDB", "id": "JVNDB-2021-010133" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-901" }, { "db": "NVD", "id": "CVE-2020-28400" } ] }, "id": "VAR-202107-1608", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.5447269509677419 }, "last_update_date": "2024-08-14T12:06:49.974000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-599968", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf" }, { "title": "Siemens Various product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=156594" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=77fc0ba2dcd8966c9a1f7eb47b8603ca" } ], "sources": [ { "db": "VULMON", "id": "CVE-2020-28400" }, { "db": "JVNDB", "id": "JVNDB-2021-010133" }, { "db": "CNNVD", "id": "CNNVD-202107-901" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-770", "trust": 1.0 }, { "problemtype": "Allocation of resources without limits or throttling (CWE-770) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-010133" }, { "db": "NVD", "id": "CVE-2020-28400" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.2, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf" }, { "trust": 1.0, "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-28400" }, { "trust": 0.8, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-194-03" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/siemens-ruggedcom-simatic-denial-of-service-via-profinet-dcp-reset-35890" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021071416" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2021.2401" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/770.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://cert-portal.siemens.com/productcert/txt/ssa-599968.txt" } ], "sources": [ { "db": "VULMON", "id": "CVE-2020-28400" }, { "db": "JVNDB", "id": "JVNDB-2021-010133" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-901" }, { "db": "NVD", "id": "CVE-2020-28400" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2020-28400" }, { "db": "JVNDB", "id": "JVNDB-2021-010133" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-901" }, { "db": "NVD", "id": "CVE-2020-28400" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-07-13T00:00:00", "db": "VULMON", "id": "CVE-2020-28400" }, { "date": "2022-06-22T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-010133" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-07-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202107-901" }, { "date": "2021-07-13T11:15:08.960000", "db": "NVD", "id": "CVE-2020-28400" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-07-13T00:00:00", "db": "VULMON", "id": "CVE-2020-28400" }, { "date": "2022-06-22T02:38:00", "db": "JVNDB", "id": "JVNDB-2021-010133" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2022-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202107-901" }, { "date": "2024-06-11T09:15:09.487000", "db": "NVD", "id": "CVE-2020-28400" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202107-901" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Vulnerability in limiting or non-slotting resource allocation in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-010133" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-901" } ], "trust": 1.2 } }
var-202104-1057
Vulnerability from variot
An issue was discovered in Wind River VxWorks before 6.5. There is a possible heap overflow in dhcp client. Wind River VxWorks Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202104-1057", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "scalance x204 irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics perfect harmony gh180", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2022" }, { "model": "scalance xf204-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x224", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x208 pro", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x200-4 p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x204 irt pro", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x216", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf206-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x212-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x201-3p irt pro", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x204-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204 irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic rf 182c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "vxworks", "scope": "lt", "trust": 1.0, "vendor": "windriver", "version": "6.5" }, { "model": "scalance x408", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x208", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf202-2p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x202-2p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf208", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic rf 181 eip", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x206-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x204-2ld", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x204-2ld ts", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x202-2p irt pro", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x204-2ts", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x300", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x201-3p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x206-1ld", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "ruggedcom win subscriber station", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics perfect harmony gh180", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "2015" }, { "model": "scalance xf204-2ba irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x212-2ld", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x204-2fm", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x202-2 irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf201-3p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "vxworks", "scope": "eq", "trust": 0.8, "vendor": "\u30a6\u30a4\u30f3\u30c9\u30ea\u30d0\u30fc\u682a\u5f0f\u4f1a\u793e", "version": null }, { "model": "vxworks", "scope": "eq", "trust": 0.8, "vendor": "\u30a6\u30a4\u30f3\u30c9\u30ea\u30d0\u30fc\u682a\u5f0f\u4f1a\u793e", "version": "6.5" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-005466" }, { "db": "NVD", "id": "CVE-2021-29998" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Mitsubishi Electric reported this vulnerability to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-915" } ], "trust": 0.6 }, "cve": "CVE-2021-29998", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2021-29998", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-29998", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-29998", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-29998", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2021-29998", "trust": 0.8, "value": "Critical" }, { "author": "CNNVD", "id": "CNNVD-202104-915", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-29998", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29998" }, { "db": "JVNDB", "id": "JVNDB-2021-005466" }, { "db": "CNNVD", "id": "CNNVD-202104-915" }, { "db": "NVD", "id": "CVE-2021-29998" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An issue was discovered in Wind River VxWorks before 6.5. There is a possible heap overflow in dhcp client. Wind River VxWorks Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2021-29998" }, { "db": "JVNDB", "id": "JVNDB-2021-005466" }, { "db": "VULMON", "id": "CVE-2021-29998" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29998", "trust": 3.3 }, { "db": "ICS CERT", "id": "ICSA-21-194-12", "trust": 1.7 }, { "db": "SIEMENS", "id": "SSA-560465", "trust": 1.7 }, { "db": "SIEMENS", "id": "SSA-910883", "trust": 1.6 }, { "db": "ICS CERT", "id": "ICSA-22-102-02", "trust": 1.5 }, { "db": "JVN", "id": "JVNVU92475198", "trust": 0.8 }, { "db": "JVN", "id": "JVNVU97764115", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-005466", "trust": 0.8 }, { "db": "CS-HELP", "id": "SB2022071403", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2022041320", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-915", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29998", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29998" }, { "db": "JVNDB", "id": "JVNDB-2021-005466" }, { "db": "CNNVD", "id": "CNNVD-202104-915" }, { "db": "NVD", "id": "CVE-2021-29998" } ] }, "id": "VAR-202104-1057", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.46321214 }, "last_update_date": "2024-11-23T21:32:18.715000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "CVE-2021-29998", "trust": 0.8, "url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2021-29998" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=fc21b995a19e3c9e8671f01654bfbb04" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29998" }, { "db": "JVNDB", "id": "JVNDB-2021-005466" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-005466" }, { "db": "NVD", "id": "CVE-2021-29998" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://support2.windriver.com/index.php?page=security-notices" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-560465.pdf" }, { "trust": 1.7, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-12" }, { "trust": 1.6, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-910883.pdf" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29998" }, { "trust": 0.9, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-102-02" }, { "trust": 0.8, "url": "http://jvn.jp/vu/jvnvu92475198/index.html" }, { "trust": 0.8, "url": "http://jvn.jp/vu/jvnvu97764115/index.html" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-102-02" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/wind-river-vxworks-buffer-overflow-via-dhcp-client-35076" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2022041320" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2022071403" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/787.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29998" }, { "db": "JVNDB", "id": "JVNDB-2021-005466" }, { "db": "CNNVD", "id": "CNNVD-202104-915" }, { "db": "NVD", "id": "CVE-2021-29998" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29998" }, { "db": "JVNDB", "id": "JVNDB-2021-005466" }, { "db": "CNNVD", "id": "CNNVD-202104-915" }, { "db": "NVD", "id": "CVE-2021-29998" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-13T00:00:00", "db": "VULMON", "id": "CVE-2021-29998" }, { "date": "2021-12-14T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-005466" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-915" }, { "date": "2021-04-13T17:15:12.310000", "db": "NVD", "id": "CVE-2021-29998" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-04-22T00:00:00", "db": "VULMON", "id": "CVE-2021-29998" }, { "date": "2022-07-15T02:01:00", "db": "JVNDB", "id": "JVNDB-2021-005466" }, { "date": "2022-07-15T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-915" }, { "date": "2024-11-21T06:02:08.550000", "db": "NVD", "id": "CVE-2021-29998" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-915" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Wind\u00a0River\u00a0VxWorks\u00a0 Out-of-bounds write vulnerability in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-005466" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-915" } ], "trust": 0.6 } }
cve-2021-25669
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-187092.pdf | x_refsource_MISC |
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SCALANCE X200-4P IRT |
Version: All versions < 5.5.1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:11:27.908Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-187092.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SCALANCE X200-4P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 5.5.1" } ] }, { "product": "SCALANCE X201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 5.5.1" } ] }, { "product": "SCALANCE X201-3P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 5.5.1" } ] }, { "product": "SCALANCE X202-2 IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 5.5.1" } ] }, { "product": "SCALANCE X202-2P IRT (incl. SIPLUS NET variant)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 5.5.1" } ] }, { "product": "SCALANCE X202-2P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 5.5.1" } ] }, { "product": "SCALANCE X204 IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 5.5.1" } ] }, { "product": "SCALANCE X204 IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 5.5.1" } ] }, { "product": "SCALANCE X204-2 (incl. SIPLUS NET variant)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X204-2FM", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X204-2LD (incl. SIPLUS NET variant)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X204-2LD TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X204-2TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X206-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X206-1LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X208 (incl. SIPLUS NET variant)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X208PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X212-2 (incl. SIPLUS NET variant)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X212-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X224", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE XF201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 5.5.1" } ] }, { "product": "SCALANCE XF202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 5.5.1" } ] }, { "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE XF204 IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 5.5.1" } ] }, { "product": "SCALANCE XF204-2 (incl. SIPLUS NET variant)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE XF204-2BA IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 5.5.1" } ] }, { "product": "SCALANCE XF206-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE XF208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c 5.5.1), SCALANCE X201-3P IRT (All versions \u003c 5.5.1), SCALANCE X201-3P IRT PRO (All versions \u003c 5.5.1), SCALANCE X202-2 IRT (All versions \u003c 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions \u003c 5.5.1), SCALANCE X202-2P IRT PRO (All versions \u003c 5.5.1), SCALANCE X204 IRT (All versions \u003c 5.5.1), SCALANCE X204 IRT PRO (All versions \u003c 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X204-2FM (All versions \u003c V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X204-2LD TS (All versions \u003c V5.2.5), SCALANCE X204-2TS (All versions \u003c V5.2.5), SCALANCE X206-1 (All versions \u003c V5.2.5), SCALANCE X206-1LD (All versions \u003c V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X208PRO (All versions \u003c V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X212-2LD (All versions \u003c V5.2.5), SCALANCE X216 (All versions \u003c V5.2.5), SCALANCE X224 (All versions \u003c V5.2.5), SCALANCE XF201-3P IRT (All versions \u003c 5.5.1), SCALANCE XF202-2P IRT (All versions \u003c 5.5.1), SCALANCE XF204 (All versions \u003c V5.2.5), SCALANCE XF204 IRT (All versions \u003c 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE XF204-2BA IRT (All versions \u003c 5.5.1), SCALANCE XF206-1 (All versions \u003c V5.2.5), SCALANCE XF208 (All versions \u003c V5.2.5). Incorrect processing of POST requests in the web server may write out of bounds in stack. An attacker might leverage this to denial-of-service of the device or remote code execution." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121: Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-09-14T10:47:24", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-187092.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-25669", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SCALANCE X200-4P IRT", "version": { "version_data": [ { "version_value": "All versions \u003c 5.5.1" } ] } }, { "product_name": "SCALANCE X201-3P IRT", "version": { "version_data": [ { "version_value": "All versions \u003c 5.5.1" } ] } }, { "product_name": "SCALANCE X201-3P IRT PRO", "version": { "version_data": [ { "version_value": "All versions \u003c 5.5.1" } ] } }, { "product_name": "SCALANCE X202-2 IRT", "version": { "version_data": [ { "version_value": "All versions \u003c 5.5.1" } ] } }, { "product_name": "SCALANCE X202-2P IRT (incl. SIPLUS NET variant)", "version": { "version_data": [ { "version_value": "All versions \u003c 5.5.1" } ] } }, { "product_name": "SCALANCE X202-2P IRT PRO", "version": { "version_data": [ { "version_value": "All versions \u003c 5.5.1" } ] } }, { "product_name": "SCALANCE X204 IRT", "version": { "version_data": [ { "version_value": "All versions \u003c 5.5.1" } ] } }, { "product_name": "SCALANCE X204 IRT PRO", "version": { "version_data": [ { "version_value": "All versions \u003c 5.5.1" } ] } }, { "product_name": "SCALANCE X204-2 (incl. SIPLUS NET variant)", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X204-2FM", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X204-2LD (incl. SIPLUS NET variant)", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X204-2LD TS", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X204-2TS", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X206-1", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X206-1LD", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X208 (incl. SIPLUS NET variant)", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X208PRO", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X212-2 (incl. SIPLUS NET variant)", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X212-2LD", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X216", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X224", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE XF201-3P IRT", "version": { "version_data": [ { "version_value": "All versions \u003c 5.5.1" } ] } }, { "product_name": "SCALANCE XF202-2P IRT", "version": { "version_data": [ { "version_value": "All versions \u003c 5.5.1" } ] } }, { "product_name": "SCALANCE XF204", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE XF204 IRT", "version": { "version_data": [ { "version_value": "All versions \u003c 5.5.1" } ] } }, { "product_name": "SCALANCE XF204-2 (incl. SIPLUS NET variant)", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE XF204-2BA IRT", "version": { "version_data": [ { "version_value": "All versions \u003c 5.5.1" } ] } }, { "product_name": "SCALANCE XF206-1", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE XF208", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c 5.5.1), SCALANCE X201-3P IRT (All versions \u003c 5.5.1), SCALANCE X201-3P IRT PRO (All versions \u003c 5.5.1), SCALANCE X202-2 IRT (All versions \u003c 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions \u003c 5.5.1), SCALANCE X202-2P IRT PRO (All versions \u003c 5.5.1), SCALANCE X204 IRT (All versions \u003c 5.5.1), SCALANCE X204 IRT PRO (All versions \u003c 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X204-2FM (All versions \u003c V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X204-2LD TS (All versions \u003c V5.2.5), SCALANCE X204-2TS (All versions \u003c V5.2.5), SCALANCE X206-1 (All versions \u003c V5.2.5), SCALANCE X206-1LD (All versions \u003c V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X208PRO (All versions \u003c V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X212-2LD (All versions \u003c V5.2.5), SCALANCE X216 (All versions \u003c V5.2.5), SCALANCE X224 (All versions \u003c V5.2.5), SCALANCE XF201-3P IRT (All versions \u003c 5.5.1), SCALANCE XF202-2P IRT (All versions \u003c 5.5.1), SCALANCE XF204 (All versions \u003c V5.2.5), SCALANCE XF204 IRT (All versions \u003c 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE XF204-2BA IRT (All versions \u003c 5.5.1), SCALANCE XF206-1 (All versions \u003c V5.2.5), SCALANCE XF208 (All versions \u003c V5.2.5). Incorrect processing of POST requests in the web server may write out of bounds in stack. An attacker might leverage this to denial-of-service of the device or remote code execution." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-121: Stack-based Buffer Overflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-187092.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-187092.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-25669", "datePublished": "2021-04-22T20:42:20", "dateReserved": "2021-01-21T00:00:00", "dateUpdated": "2024-08-03T20:11:27.908Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-25668
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-187092.pdf | x_refsource_MISC |
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SCALANCE X200-4P IRT |
Version: All versions < 5.5.1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:11:27.504Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-187092.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SCALANCE X200-4P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 5.5.1" } ] }, { "product": "SCALANCE X201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 5.5.1" } ] }, { "product": "SCALANCE X201-3P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 5.5.1" } ] }, { "product": "SCALANCE X202-2 IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 5.5.1" } ] }, { "product": "SCALANCE X202-2P IRT (incl. SIPLUS NET variant)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 5.5.1" } ] }, { "product": "SCALANCE X202-2P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 5.5.1" } ] }, { "product": "SCALANCE X204 IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 5.5.1" } ] }, { "product": "SCALANCE X204 IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 5.5.1" } ] }, { "product": "SCALANCE X204-2 (incl. SIPLUS NET variant)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X204-2FM", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X204-2LD (incl. SIPLUS NET variant)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X204-2LD TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X204-2TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X206-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X206-1LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X208 (incl. SIPLUS NET variant)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X208PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X212-2 (incl. SIPLUS NET variant)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X212-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X224", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE XF201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 5.5.1" } ] }, { "product": "SCALANCE XF202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 5.5.1" } ] }, { "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE XF204 IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 5.5.1" } ] }, { "product": "SCALANCE XF204-2 (incl. SIPLUS NET variant)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE XF204-2BA IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 5.5.1" } ] }, { "product": "SCALANCE XF206-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE XF208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c 5.5.1), SCALANCE X201-3P IRT (All versions \u003c 5.5.1), SCALANCE X201-3P IRT PRO (All versions \u003c 5.5.1), SCALANCE X202-2 IRT (All versions \u003c 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions \u003c 5.5.1), SCALANCE X202-2P IRT PRO (All versions \u003c 5.5.1), SCALANCE X204 IRT (All versions \u003c 5.5.1), SCALANCE X204 IRT PRO (All versions \u003c 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X204-2FM (All versions \u003c V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X204-2LD TS (All versions \u003c V5.2.5), SCALANCE X204-2TS (All versions \u003c V5.2.5), SCALANCE X206-1 (All versions \u003c V5.2.5), SCALANCE X206-1LD (All versions \u003c V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X208PRO (All versions \u003c V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X212-2LD (All versions \u003c V5.2.5), SCALANCE X216 (All versions \u003c V5.2.5), SCALANCE X224 (All versions \u003c V5.2.5), SCALANCE XF201-3P IRT (All versions \u003c 5.5.1), SCALANCE XF202-2P IRT (All versions \u003c 5.5.1), SCALANCE XF204 (All versions \u003c V5.2.5), SCALANCE XF204 IRT (All versions \u003c 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE XF204-2BA IRT (All versions \u003c 5.5.1), SCALANCE XF206-1 (All versions \u003c V5.2.5), SCALANCE XF208 (All versions \u003c V5.2.5). Incorrect processing of POST requests in the webserver may result in write out of bounds in heap. An attacker might leverage this to cause denial-of-service on the device and potentially remotely execute code." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-122", "description": "CWE-122: Heap-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-09-14T10:47:23", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-187092.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-25668", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SCALANCE X200-4P IRT", "version": { "version_data": [ { "version_value": "All versions \u003c 5.5.1" } ] } }, { "product_name": "SCALANCE X201-3P IRT", "version": { "version_data": [ { "version_value": "All versions \u003c 5.5.1" } ] } }, { "product_name": "SCALANCE X201-3P IRT PRO", "version": { "version_data": [ { "version_value": "All versions \u003c 5.5.1" } ] } }, { "product_name": "SCALANCE X202-2 IRT", "version": { "version_data": [ { "version_value": "All versions \u003c 5.5.1" } ] } }, { "product_name": "SCALANCE X202-2P IRT (incl. SIPLUS NET variant)", "version": { "version_data": [ { "version_value": "All versions \u003c 5.5.1" } ] } }, { "product_name": "SCALANCE X202-2P IRT PRO", "version": { "version_data": [ { "version_value": "All versions \u003c 5.5.1" } ] } }, { "product_name": "SCALANCE X204 IRT", "version": { "version_data": [ { "version_value": "All versions \u003c 5.5.1" } ] } }, { "product_name": "SCALANCE X204 IRT PRO", "version": { "version_data": [ { "version_value": "All versions \u003c 5.5.1" } ] } }, { "product_name": "SCALANCE X204-2 (incl. SIPLUS NET variant)", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X204-2FM", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X204-2LD (incl. SIPLUS NET variant)", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X204-2LD TS", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X204-2TS", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X206-1", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X206-1LD", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X208 (incl. SIPLUS NET variant)", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X208PRO", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X212-2 (incl. SIPLUS NET variant)", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X212-2LD", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X216", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X224", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE XF201-3P IRT", "version": { "version_data": [ { "version_value": "All versions \u003c 5.5.1" } ] } }, { "product_name": "SCALANCE XF202-2P IRT", "version": { "version_data": [ { "version_value": "All versions \u003c 5.5.1" } ] } }, { "product_name": "SCALANCE XF204", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE XF204 IRT", "version": { "version_data": [ { "version_value": "All versions \u003c 5.5.1" } ] } }, { "product_name": "SCALANCE XF204-2 (incl. SIPLUS NET variant)", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE XF204-2BA IRT", "version": { "version_data": [ { "version_value": "All versions \u003c 5.5.1" } ] } }, { "product_name": "SCALANCE XF206-1", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE XF208", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c 5.5.1), SCALANCE X201-3P IRT (All versions \u003c 5.5.1), SCALANCE X201-3P IRT PRO (All versions \u003c 5.5.1), SCALANCE X202-2 IRT (All versions \u003c 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions \u003c 5.5.1), SCALANCE X202-2P IRT PRO (All versions \u003c 5.5.1), SCALANCE X204 IRT (All versions \u003c 5.5.1), SCALANCE X204 IRT PRO (All versions \u003c 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X204-2FM (All versions \u003c V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X204-2LD TS (All versions \u003c V5.2.5), SCALANCE X204-2TS (All versions \u003c V5.2.5), SCALANCE X206-1 (All versions \u003c V5.2.5), SCALANCE X206-1LD (All versions \u003c V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X208PRO (All versions \u003c V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X212-2LD (All versions \u003c V5.2.5), SCALANCE X216 (All versions \u003c V5.2.5), SCALANCE X224 (All versions \u003c V5.2.5), SCALANCE XF201-3P IRT (All versions \u003c 5.5.1), SCALANCE XF202-2P IRT (All versions \u003c 5.5.1), SCALANCE XF204 (All versions \u003c V5.2.5), SCALANCE XF204 IRT (All versions \u003c 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE XF204-2BA IRT (All versions \u003c 5.5.1), SCALANCE XF206-1 (All versions \u003c V5.2.5), SCALANCE XF208 (All versions \u003c V5.2.5). Incorrect processing of POST requests in the webserver may result in write out of bounds in heap. An attacker might leverage this to cause denial-of-service on the device and potentially remotely execute code." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-122: Heap-based Buffer Overflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-187092.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-187092.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-25668", "datePublished": "2021-04-22T20:42:20", "dateReserved": "2021-01-21T00:00:00", "dateUpdated": "2024-08-03T20:11:27.504Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }