All the vulnerabilites related to Siemens - SCALANCE X204-2LD
var-202210-0551
Vulnerability from variot
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.0), SCALANCE X201-3P IRT (All versions < V5.5.0), SCALANCE X201-3P IRT PRO (All versions < V5.5.0), SCALANCE X202-2IRT (All versions < V5.5.0), SCALANCE X202-2P IRT (All versions < V5.5.0), SCALANCE X202-2P IRT PRO (All versions < V5.5.0), SCALANCE X204-2 (All versions < V5.2.5), SCALANCE X204-2FM (All versions < V5.2.5), SCALANCE X204-2LD (All versions < V5.2.5), SCALANCE X204-2LD TS (All versions < V5.2.5), SCALANCE X204-2TS (All versions < V5.2.5), SCALANCE X204IRT (All versions < V5.5.0), SCALANCE X204IRT PRO (All versions < V5.5.0), SCALANCE X206-1 (All versions < V5.2.5), SCALANCE X206-1LD (All versions < V5.2.5), SCALANCE X208 (All versions < V5.2.5), SCALANCE X208PRO (All versions < V5.2.5), SCALANCE X212-2 (All versions < V5.2.5), SCALANCE X212-2LD (All versions < V5.2.5), SCALANCE X216 (All versions < V5.2.5), SCALANCE X224 (All versions < V5.2.5), SCALANCE XF201-3P IRT (All versions < V5.5.0), SCALANCE XF202-2P IRT (All versions < V5.5.0), SCALANCE XF204 (All versions < V5.2.5), SCALANCE XF204-2 (All versions < V5.2.5), SCALANCE XF204-2BA IRT (All versions < V5.5.0), SCALANCE XF204IRT (All versions < V5.5.0), SCALANCE XF206-1 (All versions < V5.2.5), SCALANCE XF208 (All versions < V5.2.5), SIPLUS NET SCALANCE X202-2P IRT (All versions < V5.5.0). There is a cross-site scripting vulnerability on the affected devices, that if used by a threat actor, it could result in session hijacking. scalance x200-4p irt firmware, SCALANCE X201-3P IRT firmware, SCALANCE X201-3P IRT PRO Multiple Siemens products such as firmware contain a cross-site scripting vulnerability.Information may be obtained and information may be tampered with
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202210-0551", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "scalance x208", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf204", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x224", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf201-3p irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x201-3p irt pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x204-2ts", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x206-1ld", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x216", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf206-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf204irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x204-2fm", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2ld", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x212-2ld", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf202-2p irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance xf204-2ba irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x204irt pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance xf208", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x202-2irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x206-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x200-4p irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance xf204-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x202-2p irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x202-2p irt pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "siplus net scalance x202-2p irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x204-2ld ts", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x201-3p irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x208pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x212-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x201-3p irt", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x201-3p irt pro", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x204-2ts", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x204irt pro", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x206-1ld", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x202-2irt", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x208pro", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x212-2ld", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x200-4p irt", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x202-2p irt", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x202-2p irt pro", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x204-2ld ts", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x204irt", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x216", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x204-2fm", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x206-1", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x204-2ld", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x208", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x204-2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x212-2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-018712" }, { "db": "NVD", "id": "CVE-2022-40631" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported this vulnerability to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-504" } ], "trust": 0.6 }, "cve": "CVE-2022-40631", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 2.8, "id": "CVE-2022-40631", "impactScore": 2.7, "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 6.1, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "CVE-2022-40631", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-40631", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2022-40631", "trust": 0.8, "value": "Medium" }, { "author": "CNNVD", "id": "CNNVD-202210-504", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-018712" }, { "db": "CNNVD", "id": "CNNVD-202210-504" }, { "db": "NVD", "id": "CVE-2022-40631" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c V5.5.0), SCALANCE X201-3P IRT (All versions \u003c V5.5.0), SCALANCE X201-3P IRT PRO (All versions \u003c V5.5.0), SCALANCE X202-2IRT (All versions \u003c V5.5.0), SCALANCE X202-2P IRT (All versions \u003c V5.5.0), SCALANCE X202-2P IRT PRO (All versions \u003c V5.5.0), SCALANCE X204-2 (All versions \u003c V5.2.5), SCALANCE X204-2FM (All versions \u003c V5.2.5), SCALANCE X204-2LD (All versions \u003c V5.2.5), SCALANCE X204-2LD TS (All versions \u003c V5.2.5), SCALANCE X204-2TS (All versions \u003c V5.2.5), SCALANCE X204IRT (All versions \u003c V5.5.0), SCALANCE X204IRT PRO (All versions \u003c V5.5.0), SCALANCE X206-1 (All versions \u003c V5.2.5), SCALANCE X206-1LD (All versions \u003c V5.2.5), SCALANCE X208 (All versions \u003c V5.2.5), SCALANCE X208PRO (All versions \u003c V5.2.5), SCALANCE X212-2 (All versions \u003c V5.2.5), SCALANCE X212-2LD (All versions \u003c V5.2.5), SCALANCE X216 (All versions \u003c V5.2.5), SCALANCE X224 (All versions \u003c V5.2.5), SCALANCE XF201-3P IRT (All versions \u003c V5.5.0), SCALANCE XF202-2P IRT (All versions \u003c V5.5.0), SCALANCE XF204 (All versions \u003c V5.2.5), SCALANCE XF204-2 (All versions \u003c V5.2.5), SCALANCE XF204-2BA IRT (All versions \u003c V5.5.0), SCALANCE XF204IRT (All versions \u003c V5.5.0), SCALANCE XF206-1 (All versions \u003c V5.2.5), SCALANCE XF208 (All versions \u003c V5.2.5), SIPLUS NET SCALANCE X202-2P IRT (All versions \u003c V5.5.0). There is a cross-site scripting vulnerability on the affected devices, that if used by a threat actor, it could result in session hijacking. scalance x200-4p irt firmware, SCALANCE X201-3P IRT firmware, SCALANCE X201-3P IRT PRO Multiple Siemens products such as firmware contain a cross-site scripting vulnerability.Information may be obtained and information may be tampered with", "sources": [ { "db": "NVD", "id": "CVE-2022-40631" }, { "db": "JVNDB", "id": "JVNDB-2022-018712" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-40631", "trust": 3.2 }, { "db": "SIEMENS", "id": "SSA-501891", "trust": 2.4 }, { "db": "ICS CERT", "id": "ICSA-22-286-15", "trust": 1.4 }, { "db": "JVN", "id": "JVNVU92214181", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2022-018712", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202210-504", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-018712" }, { "db": "CNNVD", "id": "CNNVD-202210-504" }, { "db": "NVD", "id": "CVE-2022-40631" } ] }, "id": "VAR-202210-0551", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.5104343616666666 }, "last_update_date": "2024-08-14T12:41:47.096000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Siemens Scalance X-200 Fixes for cross-site scripting vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=210803" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-504" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-79", "trust": 1.0 }, { "problemtype": "Cross-site scripting (CWE-79) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-018712" }, { "db": "NVD", "id": "CVE-2022-40631" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-501891.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu92214181/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-40631" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-286-15" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-286-15" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-40631/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-018712" }, { "db": "CNNVD", "id": "CNNVD-202210-504" }, { "db": "NVD", "id": "CVE-2022-40631" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2022-018712" }, { "db": "CNNVD", "id": "CNNVD-202210-504" }, { "db": "NVD", "id": "CVE-2022-40631" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-10-23T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-018712" }, { "date": "2022-10-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202210-504" }, { "date": "2022-10-11T11:15:10.997000", "db": "NVD", "id": "CVE-2022-40631" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-10-23T02:34:00", "db": "JVNDB", "id": "JVNDB-2022-018712" }, { "date": "2022-10-17T00:00:00", "db": "CNNVD", "id": "CNNVD-202210-504" }, { "date": "2022-10-14T17:07:54.777000", "db": "NVD", "id": "CVE-2022-40631" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-504" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cross-site scripting vulnerability in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-018712" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "XSS", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-504" } ], "trust": 0.6 } }
var-201309-0316
Vulnerability from variot
The authentication implementation in the web server on Siemens SCALANCE X-200 switches with firmware before 5.0.0 does not use a sufficient source of entropy for generating values of random numbers, which makes it easier for remote attackers to hijack sessions by predicting a value. The Siemens Scalance X200 is an industrial Ethernet switch from Siemens. Remote attackers can exploit this issue to hijack web sessions over the network without authentication. Other attacks are also possible. Siemens Scalance X-200 Series switches running firmware versions prior to 5.0.0 are vulnerable
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201309-0316", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "scalance x-200 series", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "4.3" }, { "model": "scalance x204irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance x-200 series", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "4.4" }, { "model": "scalance x-200", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xf-200", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance x202-2irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance x-200rna", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance x202-2p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance x201-3p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance x200-4p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance x-200", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "scalance x-200 series", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "5.0.0" }, { "model": "scalance x-200rna", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "scalance x200-4pirt", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "scalance x201-3p irt", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "scalance x202-2irt", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "scalance x202-2p irt", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "scalance x204irt", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "scalance xf-200", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "scalance series switches", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x-200" }, { "model": "scalance x-200 series", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "4.4" }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "scalance x202 2p irt", "version": null }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "scalance x204irt", "version": null }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "scalance x201 3p irt", "version": null }, { "model": "scalance xf208", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "scalance xf206-1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "scalance xf204-2", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "scalance xf204", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "scalance", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "x2240" }, { "model": "scalance", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "x2160" }, { "model": "scalance x212-2ld", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "scalance", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "x212-20" }, { "model": "scalance x208pro", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "scalance", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "x2080" }, { "model": "scalance x206-1ld", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "scalance", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "x206-10" }, { "model": "scalance x204-2ts", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "scalance x204-2ld", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "scalance", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "x204-20" }, { "model": "scalance xf208", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "5.0" }, { "model": "scalance xf206-1", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "5.0" }, { "model": "scalance xf204-2", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "5.0" }, { "model": "scalance xf204", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "5.0" }, { "model": "scalance", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "x2245.0" }, { "model": "scalance", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "x2165.0" }, { "model": "scalance x212-2ld", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "5.0" }, { "model": "scalance", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "x212-25.0" }, { "model": "scalance x208pro", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "5.0" }, { "model": "scalance", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "x2085.0" }, { "model": "scalance x206-1ld", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "5.0" }, { "model": "scalance x204-2ts", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "5.0" }, { "model": "scalance x204-2ld", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "5.0" }, { "model": "scalance", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "x204-25.0" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance x 200rna", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance x 200 series", "version": "4.4" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance x 200", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance x200 4p irt", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance x 200 series", "version": "4.3" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance x202 2irt", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance xf 200", "version": null } ], "sources": [ { "db": "IVD", "id": "abb36416-2352-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2013-13027" }, { "db": "BID", "id": "62341" }, { "db": "JVNDB", "id": "JVNDB-2013-004188" }, { "db": "CNNVD", "id": "CNNVD-201309-245" }, { "db": "NVD", "id": "CVE-2013-5709" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/h:siemens:scalance_x-200", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:scalance_x-200_series_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/h:siemens:scalance_x-200rna", "vulnerable": true }, { "cpe22Uri": "cpe:/h:siemens:scalance_x200-4p_irt", "vulnerable": true }, { "cpe22Uri": "cpe:/h:siemens:scalance_x201-3p_irt", "vulnerable": true }, { "cpe22Uri": "cpe:/h:siemens:scalance_x202-2irt", "vulnerable": true }, { "cpe22Uri": "cpe:/h:siemens:scalance_x202-2p_irt", "vulnerable": true }, { "cpe22Uri": "cpe:/h:siemens:scalance_x204irt", "vulnerable": true }, { "cpe22Uri": "cpe:/h:siemens:scalance_xf-200", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2013-004188" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Eireann Leverett of IOActive", "sources": [ { "db": "BID", "id": "62341" }, { "db": "CNNVD", "id": "CNNVD-201309-245" } ], "trust": 0.9 }, "cve": "CVE-2013-5709", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "CVE-2013-5709", "impactScore": 8.5, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:C", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "CNVD-2013-13027", "impactScore": 8.5, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:C", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "abb36416-2352-11e6-abef-000c29c66e3d", "impactScore": 8.5, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "VHN-65711", "impactScore": 8.5, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:C", "version": "2.0" } ], "cvssV3": [], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2013-5709", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2013-5709", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2013-13027", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201309-245", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "abb36416-2352-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-65711", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "IVD", "id": "abb36416-2352-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2013-13027" }, { "db": "VULHUB", "id": "VHN-65711" }, { "db": "JVNDB", "id": "JVNDB-2013-004188" }, { "db": "CNNVD", "id": "CNNVD-201309-245" }, { "db": "NVD", "id": "CVE-2013-5709" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "The authentication implementation in the web server on Siemens SCALANCE X-200 switches with firmware before 5.0.0 does not use a sufficient source of entropy for generating values of random numbers, which makes it easier for remote attackers to hijack sessions by predicting a value. The Siemens Scalance X200 is an industrial Ethernet switch from Siemens. \nRemote attackers can exploit this issue to hijack web sessions over the network without authentication. Other attacks are also possible. \nSiemens Scalance X-200 Series switches running firmware versions prior to 5.0.0 are vulnerable", "sources": [ { "db": "NVD", "id": "CVE-2013-5709" }, { "db": "JVNDB", "id": "JVNDB-2013-004188" }, { "db": "CNVD", "id": "CNVD-2013-13027" }, { "db": "BID", "id": "62341" }, { "db": "IVD", "id": "abb36416-2352-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-65711" } ], "trust": 2.7 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2013-5709", "trust": 3.6 }, { "db": "ICS CERT", "id": "ICSA-13-254-01", "trust": 2.8 }, { "db": "SIEMENS", "id": "SSA-850708", "trust": 2.3 }, { "db": "BID", "id": "62341", "trust": 1.0 }, { "db": "CNNVD", "id": "CNNVD-201309-245", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2013-13027", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2013-004188", "trust": 0.8 }, { "db": "SECUNIA", "id": "54784", "trust": 0.6 }, { "db": "IVD", "id": "ABB36416-2352-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "SEEBUG", "id": "SSVID-89653", "trust": 0.1 }, { "db": "VULHUB", "id": "VHN-65711", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "abb36416-2352-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2013-13027" }, { "db": "VULHUB", "id": "VHN-65711" }, { "db": "BID", "id": "62341" }, { "db": "JVNDB", "id": "JVNDB-2013-004188" }, { "db": "CNNVD", "id": "CNNVD-201309-245" }, { "db": "NVD", "id": "CVE-2013-5709" } ] }, "id": "VAR-201309-0316", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "abb36416-2352-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2013-13027" }, { "db": "VULHUB", "id": "VHN-65711" } ], "trust": 1.4751035300000002 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS", "Network device" ], "sub_category": null, "trust": 0.6 }, { "category": [ "ICS" ], "sub_category": null, "trust": 0.2 } ], "sources": [ { "db": "IVD", "id": "abb36416-2352-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2013-13027" } ] }, "last_update_date": "2024-11-23T22:08:30.113000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-850708", "trust": 0.8, "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-850708.pdf" }, { "title": "Patch for the Siemens SCALANCE X-200 Series Switch Session Hijacking Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/39576" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2013-13027" }, { "db": "JVNDB", "id": "JVNDB-2013-004188" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-189", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-65711" }, { "db": "JVNDB", "id": "JVNDB-2013-004188" }, { "db": "NVD", "id": "CVE-2013-5709" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "http://ics-cert.us-cert.gov/advisories/icsa-13-254-01" }, { "trust": 1.7, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-850708.pdf" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-850708.pdf" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2013-5709" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2013-5709" }, { "trust": 0.6, "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-850708.pdf" }, { "trust": 0.6, "url": "http://www.secunia.com/advisories/54784/" }, { "trust": 0.3, "url": "http://subscriber.communications.siemens.com/" }, { "trust": 0.3, "url": "http://ics-cert.us-cert.gov/advisories/icsa-13-254-01#footnoteb_gtr58ow" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2013-13027" }, { "db": "VULHUB", "id": "VHN-65711" }, { "db": "BID", "id": "62341" }, { "db": "JVNDB", "id": "JVNDB-2013-004188" }, { "db": "CNNVD", "id": "CNNVD-201309-245" }, { "db": "NVD", "id": "CVE-2013-5709" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "abb36416-2352-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2013-13027" }, { "db": "VULHUB", "id": "VHN-65711" }, { "db": "BID", "id": "62341" }, { "db": "JVNDB", "id": "JVNDB-2013-004188" }, { "db": "CNNVD", "id": "CNNVD-201309-245" }, { "db": "NVD", "id": "CVE-2013-5709" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2013-09-17T00:00:00", "db": "IVD", "id": "abb36416-2352-11e6-abef-000c29c66e3d" }, { "date": "2013-09-16T00:00:00", "db": "CNVD", "id": "CNVD-2013-13027" }, { "date": "2013-09-17T00:00:00", "db": "VULHUB", "id": "VHN-65711" }, { "date": "2013-09-11T00:00:00", "db": "BID", "id": "62341" }, { "date": "2013-09-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2013-004188" }, { "date": "2013-09-17T00:00:00", "db": "CNNVD", "id": "CNNVD-201309-245" }, { "date": "2013-09-17T12:04:28.820000", "db": "NVD", "id": "CVE-2013-5709" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2013-09-17T00:00:00", "db": "CNVD", "id": "CNVD-2013-13027" }, { "date": "2020-02-10T00:00:00", "db": "VULHUB", "id": "VHN-65711" }, { "date": "2013-09-11T00:00:00", "db": "BID", "id": "62341" }, { "date": "2013-09-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2013-004188" }, { "date": "2020-02-11T00:00:00", "db": "CNNVD", "id": "CNNVD-201309-245" }, { "date": "2024-11-21T01:57:59.320000", "db": "NVD", "id": "CVE-2013-5709" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201309-245" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens SCALANCE X-200 Series Switch Session Hijacking Vulnerability", "sources": [ { "db": "IVD", "id": "abb36416-2352-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2013-13027" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "digital error", "sources": [ { "db": "CNNVD", "id": "CNNVD-201309-245" } ], "trust": 0.6 } }
var-202104-1127
Vulnerability from variot
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT PRO (All versions < 5.5.1), SCALANCE X202-2 IRT (All versions < 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions < 5.5.1), SCALANCE X202-2P IRT PRO (All versions < 5.5.1), SCALANCE X204 IRT (All versions < 5.5.1), SCALANCE X204 IRT PRO (All versions < 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2FM (All versions < V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2LD TS (All versions < V5.2.5), SCALANCE X204-2TS (All versions < V5.2.5), SCALANCE X206-1 (All versions < V5.2.5), SCALANCE X206-1LD (All versions < V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X208PRO (All versions < V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X212-2LD (All versions < V5.2.5), SCALANCE X216 (All versions < V5.2.5), SCALANCE X224 (All versions < V5.2.5), SCALANCE XF201-3P IRT (All versions < 5.5.1), SCALANCE XF202-2P IRT (All versions < 5.5.1), SCALANCE XF204 (All versions < V5.2.5), SCALANCE XF204 IRT (All versions < 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE XF204-2BA IRT (All versions < 5.5.1), SCALANCE XF206-1 (All versions < V5.2.5), SCALANCE XF208 (All versions < V5.2.5). Incorrect processing of POST requests in the webserver may result in write out of bounds in heap. An attacker might leverage this to cause denial-of-service on the device and potentially remotely execute code. Siemens SCALANCE X switches are used to connect industrial components, such as programmable logic controllers (PLC) or human machine interfaces (HMI).
The Siemens SCALANCE X-200 Web server has a heap buffer overflow vulnerability. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202104-1127", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "scalance x200-4p irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x201-3p irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x201-3p irt pro", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x202-2p irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x202-2p irt pro", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance xf201-3p irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance xf202-2p irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance xf204 irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance xf204-2ba irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x202-2 irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x204 irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x204 irt pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x216", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x212-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x208pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x206-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2ts", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2ld ts", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf204", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x208", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf206-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf208", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2ld", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2fm", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x212-2ld", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf204-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x206-1ld", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x224", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance irt", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x202-2\u003c5.5.1" }, { "model": "scalance irt", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x204\u003c5.5.1" }, { "model": "scalance irt pro", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x204\u003c5.5.1" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x204-2" }, { "model": "scalance x204-2fm", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xf206-1", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xf208", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance x204-2ld", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance x204-2ld ts", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance x204-2ts", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x206-1" }, { "model": "scalance x206-1ld", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x208" }, { "model": "scalance x208pro", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x212-2" }, { "model": "scalance x212-2ld", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x216" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x224" }, { "model": "scalance xf204", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-28700" }, { "db": "NVD", "id": "CVE-2021-25668" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-988" } ], "trust": 0.6 }, "cve": "CVE-2021-25668", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2021-25668", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.1, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2021-28700", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-25668", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-25668", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2021-28700", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202104-988", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-25668", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-28700" }, { "db": "VULMON", "id": "CVE-2021-25668" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202104-988" }, { "db": "NVD", "id": "CVE-2021-25668" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c 5.5.1), SCALANCE X201-3P IRT (All versions \u003c 5.5.1), SCALANCE X201-3P IRT PRO (All versions \u003c 5.5.1), SCALANCE X202-2 IRT (All versions \u003c 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions \u003c 5.5.1), SCALANCE X202-2P IRT PRO (All versions \u003c 5.5.1), SCALANCE X204 IRT (All versions \u003c 5.5.1), SCALANCE X204 IRT PRO (All versions \u003c 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X204-2FM (All versions \u003c V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X204-2LD TS (All versions \u003c V5.2.5), SCALANCE X204-2TS (All versions \u003c V5.2.5), SCALANCE X206-1 (All versions \u003c V5.2.5), SCALANCE X206-1LD (All versions \u003c V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X208PRO (All versions \u003c V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X212-2LD (All versions \u003c V5.2.5), SCALANCE X216 (All versions \u003c V5.2.5), SCALANCE X224 (All versions \u003c V5.2.5), SCALANCE XF201-3P IRT (All versions \u003c 5.5.1), SCALANCE XF202-2P IRT (All versions \u003c 5.5.1), SCALANCE XF204 (All versions \u003c V5.2.5), SCALANCE XF204 IRT (All versions \u003c 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE XF204-2BA IRT (All versions \u003c 5.5.1), SCALANCE XF206-1 (All versions \u003c V5.2.5), SCALANCE XF208 (All versions \u003c V5.2.5). Incorrect processing of POST requests in the webserver may result in write out of bounds in heap. An attacker might leverage this to cause denial-of-service on the device and potentially remotely execute code. Siemens SCALANCE X switches are used to connect industrial components, such as programmable logic controllers (PLC) or human machine interfaces (HMI). \n\r\n\r\nThe Siemens SCALANCE X-200 Web server has a heap buffer overflow vulnerability. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements", "sources": [ { "db": "NVD", "id": "CVE-2021-25668" }, { "db": "CNVD", "id": "CNVD-2021-28700" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULMON", "id": "CVE-2021-25668" } ], "trust": 2.07 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "SIEMENS", "id": "SSA-187092", "trust": 2.3 }, { "db": "NVD", "id": "CVE-2021-25668", "trust": 2.3 }, { "db": "CNVD", "id": "CNVD-2021-28700", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021041413", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2021.1243", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-21-103-07", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-988", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-25668", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-28700" }, { "db": "VULMON", "id": "CVE-2021-25668" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202104-988" }, { "db": "NVD", "id": "CVE-2021-25668" } ] }, "id": "VAR-202104-1127", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-28700" } ], "trust": 1.1032214615384615 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-28700" } ] }, "last_update_date": "2024-11-23T19:52:37.390000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens SCALANCE X-200 Web Server Heap Buffer Overflow Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/258416" }, { "title": "Siemens Web Server Buffer error vulnerability fix", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=151765" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=00529a77c6bdb45e00924c587b6c52a5" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-28700" }, { "db": "VULMON", "id": "CVE-2021-25668" }, { "db": "CNNVD", "id": "CNNVD-202104-988" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-122", "trust": 1.0 }, { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2021-25668" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-187092.pdf" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041413" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2021.1243" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-07" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-25668" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/122.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://cert-portal.siemens.com/productcert/txt/ssa-187092.txt" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-28700" }, { "db": "VULMON", "id": "CVE-2021-25668" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202104-988" }, { "db": "NVD", "id": "CVE-2021-25668" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-28700" }, { "db": "VULMON", "id": "CVE-2021-25668" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202104-988" }, { "db": "NVD", "id": "CVE-2021-25668" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-15T00:00:00", "db": "CNVD", "id": "CNVD-2021-28700" }, { "date": "2021-04-22T00:00:00", "db": "VULMON", "id": "CVE-2021-25668" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-988" }, { "date": "2021-04-22T21:15:10.110000", "db": "NVD", "id": "CVE-2021-25668" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-15T00:00:00", "db": "CNVD", "id": "CNVD-2021-28700" }, { "date": "2021-09-14T00:00:00", "db": "VULMON", "id": "CVE-2021-25668" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-09-15T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-988" }, { "date": "2024-11-21T05:55:15.517000", "db": "NVD", "id": "CVE-2021-25668" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-988" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens SCALANCE X-200 Web Server Heap Buffer Overflow Vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2021-28700" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-975" } ], "trust": 0.6 } }
var-202104-1128
Vulnerability from variot
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT PRO (All versions < 5.5.1), SCALANCE X202-2 IRT (All versions < 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions < 5.5.1), SCALANCE X202-2P IRT PRO (All versions < 5.5.1), SCALANCE X204 IRT (All versions < 5.5.1), SCALANCE X204 IRT PRO (All versions < 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2FM (All versions < V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2LD TS (All versions < V5.2.5), SCALANCE X204-2TS (All versions < V5.2.5), SCALANCE X206-1 (All versions < V5.2.5), SCALANCE X206-1LD (All versions < V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X208PRO (All versions < V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X212-2LD (All versions < V5.2.5), SCALANCE X216 (All versions < V5.2.5), SCALANCE X224 (All versions < V5.2.5), SCALANCE XF201-3P IRT (All versions < 5.5.1), SCALANCE XF202-2P IRT (All versions < 5.5.1), SCALANCE XF204 (All versions < V5.2.5), SCALANCE XF204 IRT (All versions < 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE XF204-2BA IRT (All versions < 5.5.1), SCALANCE XF206-1 (All versions < V5.2.5), SCALANCE XF208 (All versions < V5.2.5). Incorrect processing of POST requests in the web server may write out of bounds in stack. An attacker might leverage this to denial-of-service of the device or remote code execution. Siemens SCALANCE X switches are used to connect industrial components, such as programmable logic controllers (PLC) or human machine interfaces (HMI).
The Siemens SCALANCE X-200 Web server has a stack buffer overflow vulnerability. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202104-1128", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "scalance x200-4p irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x201-3p irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x201-3p irt pro", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x202-2p irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x202-2p irt pro", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance xf201-3p irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance xf202-2p irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance xf204 irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance xf204-2ba irt", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x202-2 irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x204 irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x204 irt pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.1" }, { "model": "scalance x216", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x212-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x208pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x206-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2ts", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2ld ts", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf204", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x208", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf206-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf208", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2ld", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2fm", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x212-2ld", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf204-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x206-1ld", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x224", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance irt", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x202-2\u003c5.5.1" }, { "model": "scalance irt", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x204\u003c5.5.1" }, { "model": "scalance irt pro", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x204\u003c5.5.1" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x204-2" }, { "model": "scalance xf206-1", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xf208", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance x204-2ld", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance x204-2ld ts", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance x204-2ts", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x206-1" }, { "model": "scalance x206-1ld", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x208" }, { "model": "scalance x208pro", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x212-2" }, { "model": "scalance x212-2ld", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x216" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x224" }, { "model": "scalance xf204", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-28699" }, { "db": "NVD", "id": "CVE-2021-25669" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-984" } ], "trust": 0.6 }, "cve": "CVE-2021-25669", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2021-25669", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.1, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2021-28699", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-25669", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-25669", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2021-28699", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202104-984", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-25669", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-28699" }, { "db": "VULMON", "id": "CVE-2021-25669" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202104-984" }, { "db": "NVD", "id": "CVE-2021-25669" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c 5.5.1), SCALANCE X201-3P IRT (All versions \u003c 5.5.1), SCALANCE X201-3P IRT PRO (All versions \u003c 5.5.1), SCALANCE X202-2 IRT (All versions \u003c 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions \u003c 5.5.1), SCALANCE X202-2P IRT PRO (All versions \u003c 5.5.1), SCALANCE X204 IRT (All versions \u003c 5.5.1), SCALANCE X204 IRT PRO (All versions \u003c 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X204-2FM (All versions \u003c V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X204-2LD TS (All versions \u003c V5.2.5), SCALANCE X204-2TS (All versions \u003c V5.2.5), SCALANCE X206-1 (All versions \u003c V5.2.5), SCALANCE X206-1LD (All versions \u003c V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X208PRO (All versions \u003c V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE X212-2LD (All versions \u003c V5.2.5), SCALANCE X216 (All versions \u003c V5.2.5), SCALANCE X224 (All versions \u003c V5.2.5), SCALANCE XF201-3P IRT (All versions \u003c 5.5.1), SCALANCE XF202-2P IRT (All versions \u003c 5.5.1), SCALANCE XF204 (All versions \u003c V5.2.5), SCALANCE XF204 IRT (All versions \u003c 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions \u003c V5.2.5), SCALANCE XF204-2BA IRT (All versions \u003c 5.5.1), SCALANCE XF206-1 (All versions \u003c V5.2.5), SCALANCE XF208 (All versions \u003c V5.2.5). Incorrect processing of POST requests in the web server may write out of bounds in stack. An attacker might leverage this to denial-of-service of the device or remote code execution. Siemens SCALANCE X switches are used to connect industrial components, such as programmable logic controllers (PLC) or human machine interfaces (HMI). \n\r\n\r\nThe Siemens SCALANCE X-200 Web server has a stack buffer overflow vulnerability. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements", "sources": [ { "db": "NVD", "id": "CVE-2021-25669" }, { "db": "CNVD", "id": "CNVD-2021-28699" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULMON", "id": "CVE-2021-25669" } ], "trust": 2.07 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "SIEMENS", "id": "SSA-187092", "trust": 2.3 }, { "db": "NVD", "id": "CVE-2021-25669", "trust": 2.3 }, { "db": "CNVD", "id": "CNVD-2021-28699", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021041413", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2021.1243", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-21-103-07", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-984", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-25669", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-28699" }, { "db": "VULMON", "id": "CVE-2021-25669" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202104-984" }, { "db": "NVD", "id": "CVE-2021-25669" } ] }, "id": "VAR-202104-1128", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-28699" } ], "trust": 1.1032214615384615 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-28699" } ] }, "last_update_date": "2024-11-23T19:58:16.905000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens SCALANCE X-200 Web Server Stack Buffer Overflow Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/258421" }, { "title": "Siemens Web Server Buffer error vulnerability fix", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=151764" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=00529a77c6bdb45e00924c587b6c52a5" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-28699" }, { "db": "VULMON", "id": "CVE-2021-25669" }, { "db": "CNNVD", "id": "CNNVD-202104-984" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-121", "trust": 1.0 }, { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2021-25669" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-187092.pdf" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041413" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2021.1243" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-07" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-25669" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/787.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://cert-portal.siemens.com/productcert/txt/ssa-187092.txt" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-28699" }, { "db": "VULMON", "id": "CVE-2021-25669" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202104-984" }, { "db": "NVD", "id": "CVE-2021-25669" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-28699" }, { "db": "VULMON", "id": "CVE-2021-25669" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202104-984" }, { "db": "NVD", "id": "CVE-2021-25669" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-15T00:00:00", "db": "CNVD", "id": "CNVD-2021-28699" }, { "date": "2021-04-22T00:00:00", "db": "VULMON", "id": "CVE-2021-25669" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-984" }, { "date": "2021-04-22T21:15:10.143000", "db": "NVD", "id": "CVE-2021-25669" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-15T00:00:00", "db": "CNVD", "id": "CNVD-2021-28699" }, { "date": "2021-04-30T00:00:00", "db": "VULMON", "id": "CVE-2021-25669" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-09-15T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-984" }, { "date": "2024-11-21T05:55:15.703000", "db": "NVD", "id": "CVE-2021-25669" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-984" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens SCALANCE X-200 Web Server Stack Buffer Overflow Vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2021-28699" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-975" } ], "trust": 0.6 } }
var-202107-1608
Vulnerability from variot
Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device. Multiple Siemens products contain vulnerabilities in resource allocation without restrictions or throttling.Service operation interruption (DoS) It may be in a state. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements. Siemens SCALANCE S602是德国西门子(Siemens)公司的一款工业安全设备. Siemens多款产品 存在安全漏洞,该漏洞允许攻击者执行拒绝服务攻击。以下产品和版本受到影响:Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions), RUGGEDCOM RM1224 (All Versions < 6.4), SCALANCE M-800 (All Versions < 6.4), SCALANCE S615 (All Versions < 6.4), SCALANCE W1700 IEEE 802.11ac (All versions), SCALANCE W700 IEEE 802.11n (All versions), SCALANCE X200-4 P IRT (All Versions < V5.5.0), SCALANCE X201-3P IRT (All Versions < V5.5.0), SCALANCE X201-3P IRT PRO (All Versions < V5.5.0), SCALANCE X202-2 IRT (All Versions < V5.5.0), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All Versions < V5.5.0), SCALANCE X202-2P IRT PRO (All Versions < V5.5.0), SCALANCE X204 IRT (All Versions < V5.5.0), SCALANCE X204 IRT PRO (All Versions < V5.5.0), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions), SCALANCE X204-2FM (All versions), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions), SCALANCE X204-2LD TS (All versions), SCALANCE X204-2TS (All versions), SCALANCE X206-1 (All versions), SCALANCE X206-1LD (incl. SIPLUS NET variant) (All versions), SCALANCE X208 (incl. SIPLUS NET variant) (All versions), SCALANCE X208PRO (All versions), SCALANCE X212-2 (All versions), SCALANCE X212-2LD (All versions), SCALANCE X216 (All versions), SCALANCE X224 (All versions), SCALANCE X302-7EEC (All versions), SCALANCE X304-2FE (All versions), SCALANCE X306-1LDFE (All versions), SCALANCE X307-2EEC (All versions), SCALANCE X307-3 (All versions), SCALANCE X307-3LD (All versions), SCALANCE X308-2 (incl. SIPLUS NET variant) (All versions), SCALANCE X308-2LD (All versions), SCALANCE X308-2LH (All versions), SCALANCE X308-2LH+ (All versions), SCALANCE X308-2M (All versions), SCALANCE X308-2M POE (All versions), SCALANCE X308-2M TS (All versions), SCALANCE X310 (All versions), SCALANCE X310FE (All versions), SCALANCE X320-1FE (All versions), SCALANCE X320-3LDFE (All versions), SCALANCE XB-200 (All versions), SCALANCE XC-200 (All versions), SCALANCE XF-200BA (All versions), SCALANCE XF201-3P IRT (All Versions < V5.5.0), SCALANCE XF202-2P IRT (All Versions < V5.5.0), SCALANCE XF204 (All versions), SCALANCE XF204 IRT (All Versions < V5.5.0), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions), SCALANCE XF204-2BA IRT (All Versions < V5.5.0), SCALANCE XF206-1 (All versions), SCALANCE XF208 (All versions), SCALANCE XM400 (All versions < V6.3.1), SCALANCE XP-200 (All versions), SCALANCE XR-300WG (All versions), SCALANCE XR324-12M (All versions), SCALANCE XR324-12M TS (All versions), SCALANCE XR324-4M EEC (All versions), SCALANCE XR324-4M POE (All versions), SCALANCE XR324-4M POE TS (All versions), SCALANCE XR500 (All versions < V6.3.1), SIMATIC CFU PA (All versions), SIMATIC IE/PB-LINK V3 (All versions), SIMATIC MV500 family (All versions < V3.0), SIMATIC NET CM 1542-1 (All versions), SIMATIC NET CP1616/CP1604 (All Versions >= V2.7), SIMATIC NET CP1626 (All versions), SIMATIC NET DK-16xx PN IO (All Versions >= V2.7), SIMATIC PROFINET Driver (All versions), SIMATIC Power Line Booster PLB, Base Module (MLFB: 6ES7972-5AA10-0AB0) (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All Versions < V4.5), SIMOCODE proV Ethernet/IP (All versions < V1.1.3), SIMOCODE proV PROFINET (All versions < V2.1.3), SOFTNET-IE PNIO (All versions)
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202107-1608", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "scalance x206-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x201-3p irt pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "softnet-ie pnio", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x310fe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic net cp1604", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "2.7" }, { "model": "scalance xr324-12m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x306-1ldfe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x304-2fe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simocode prov profinet", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.1.3" }, { "model": "simatic net cm 1542-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance w1700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x206-1ld", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x308-2m poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x202-2p irt pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x310", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr324-4m poe ts", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simocode prov ethernet\\/ip", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.1.3" }, { "model": "scalance x204 irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "dk standard ethernet controller evaluation kit", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x308-2lh\\+", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204-2ba irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x308-2m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x204-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf204", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x307-3ld", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr324-4m poe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf206-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204 irt pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "simatic ie\\/pb-link v3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x308-2lh", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x308-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x307-2eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "ek-ertec 200 evaulation kit", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x320-1fe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr324-12m ts", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic power line booster plb", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic profinet driver", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3" }, { "model": "scalance x201-3p irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x208", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance m-800", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.4" }, { "model": "scalance x308-2ld", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic mv500", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "scalance x212-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xb-200", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.3" }, { "model": "scalance xf-200ba", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.3" }, { "model": "scalance x208pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2ts", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x308-2m ts", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204 irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance w700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic net dk-16xx pn io", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "2.7" }, { "model": "scalance xf202-2p irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x307-3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-1200", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.5" }, { "model": "simatic cfu pa", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr500", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.3.1" }, { "model": "scalance x302-7eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "ek-ertec 200p evaluation kit", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "scalance xf201-3p irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance xc-200", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.3" }, { "model": "scalance x200-4 p irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x204-2ld ts", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2ld", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xr-300wg", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.3" }, { "model": "scalance xp-200", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.3" }, { "model": "scalance x320-3ldfe", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance s615", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.4" }, { "model": "scalance x224", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "simatic net cp1626", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr324-4m eec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf208", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x216", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x212-2ld", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "simatic net cp1616", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "2.7" }, { "model": "scalance xm400", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.3.1" }, { "model": "ruggedcom rm1224", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.4" }, { "model": "scalance x202-2 irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x204-2fm", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x200-4p irt", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "dk standard ethernet controller evaluation kit", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance w1700", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance s615", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "ek-ertec 200p evaluation kit", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x201-3p irt", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "ek-ertec 200 evaluation kit", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance w700", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance m-800", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "ruggedcom rm1224", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-010133" }, { "db": "NVD", "id": "CVE-2020-28400" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported this vulnerability to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202107-901" } ], "trust": 0.6 }, "cve": "CVE-2020-28400", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2020-28400", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2020-28400", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2020-28400", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-28400", "trust": 1.0, "value": "HIGH" }, { "author": "productcert@siemens.com", "id": "CVE-2020-28400", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2020-28400", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202107-901", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-010133" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-901" }, { "db": "NVD", "id": "CVE-2020-28400" }, { "db": "NVD", "id": "CVE-2020-28400" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device. Multiple Siemens products contain vulnerabilities in resource allocation without restrictions or throttling.Service operation interruption (DoS) It may be in a state. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements. Siemens SCALANCE S602\u662f\u5fb7\u56fd\u897f\u95e8\u5b50\uff08Siemens\uff09\u516c\u53f8\u7684\u4e00\u6b3e\u5de5\u4e1a\u5b89\u5168\u8bbe\u5907. \nSiemens\u591a\u6b3e\u4ea7\u54c1 \u5b58\u5728\u5b89\u5168\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u5141\u8bb8\u653b\u51fb\u8005\u6267\u884c\u62d2\u7edd\u670d\u52a1\u653b\u51fb\u3002\u4ee5\u4e0b\u4ea7\u54c1\u548c\u7248\u672c\u53d7\u5230\u5f71\u54cd\uff1aDevelopment/Evaluation Kits for PROFINET IO\uff1a DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO\uff1a EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO\uff1a EK-ERTEC 200P (All versions), RUGGEDCOM RM1224 (All Versions \uff1c 6.4), SCALANCE M-800 (All Versions \uff1c 6.4), SCALANCE S615 (All Versions \uff1c 6.4), SCALANCE W1700 IEEE 802.11ac (All versions), SCALANCE W700 IEEE 802.11n (All versions), SCALANCE X200-4 P IRT (All Versions \uff1c V5.5.0), SCALANCE X201-3P IRT (All Versions \uff1c V5.5.0), SCALANCE X201-3P IRT PRO (All Versions \uff1c V5.5.0), SCALANCE X202-2 IRT (All Versions \uff1c V5.5.0), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All Versions \uff1c V5.5.0), SCALANCE X202-2P IRT PRO (All Versions \uff1c V5.5.0), SCALANCE X204 IRT (All Versions \uff1c V5.5.0), SCALANCE X204 IRT PRO (All Versions \uff1c V5.5.0), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions), SCALANCE X204-2FM (All versions), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions), SCALANCE X204-2LD TS (All versions), SCALANCE X204-2TS (All versions), SCALANCE X206-1 (All versions), SCALANCE X206-1LD (incl. SIPLUS NET variant) (All versions), SCALANCE X208 (incl. SIPLUS NET variant) (All versions), SCALANCE X208PRO (All versions), SCALANCE X212-2 (All versions), SCALANCE X212-2LD (All versions), SCALANCE X216 (All versions), SCALANCE X224 (All versions), SCALANCE X302-7EEC (All versions), SCALANCE X304-2FE (All versions), SCALANCE X306-1LDFE (All versions), SCALANCE X307-2EEC (All versions), SCALANCE X307-3 (All versions), SCALANCE X307-3LD (All versions), SCALANCE X308-2 (incl. SIPLUS NET variant) (All versions), SCALANCE X308-2LD (All versions), SCALANCE X308-2LH (All versions), SCALANCE X308-2LH+ (All versions), SCALANCE X308-2M (All versions), SCALANCE X308-2M POE (All versions), SCALANCE X308-2M TS (All versions), SCALANCE X310 (All versions), SCALANCE X310FE (All versions), SCALANCE X320-1FE (All versions), SCALANCE X320-3LDFE (All versions), SCALANCE XB-200 (All versions), SCALANCE XC-200 (All versions), SCALANCE XF-200BA (All versions), SCALANCE XF201-3P IRT (All Versions \uff1c V5.5.0), SCALANCE XF202-2P IRT (All Versions \uff1c V5.5.0), SCALANCE XF204 (All versions), SCALANCE XF204 IRT (All Versions \uff1c V5.5.0), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions), SCALANCE XF204-2BA IRT (All Versions \uff1c V5.5.0), SCALANCE XF206-1 (All versions), SCALANCE XF208 (All versions), SCALANCE XM400 (All versions \uff1c V6.3.1), SCALANCE XP-200 (All versions), SCALANCE XR-300WG (All versions), SCALANCE XR324-12M (All versions), SCALANCE XR324-12M TS (All versions), SCALANCE XR324-4M EEC (All versions), SCALANCE XR324-4M POE (All versions), SCALANCE XR324-4M POE TS (All versions), SCALANCE XR500 (All versions \uff1c V6.3.1), SIMATIC CFU PA (All versions), SIMATIC IE/PB-LINK V3 (All versions), SIMATIC MV500 family (All versions \uff1c V3.0), SIMATIC NET CM 1542-1 (All versions), SIMATIC NET CP1616/CP1604 (All Versions \uff1e= V2.7), SIMATIC NET CP1626 (All versions), SIMATIC NET DK-16xx PN IO (All Versions \uff1e= V2.7), SIMATIC PROFINET Driver (All versions), SIMATIC Power Line Booster PLB, Base Module (MLFB\uff1a 6ES7972-5AA10-0AB0) (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All Versions \uff1c V4.5), SIMOCODE proV Ethernet/IP (All versions \uff1c V1.1.3), SIMOCODE proV PROFINET (All versions \uff1c V2.1.3), SOFTNET-IE PNIO (All versions)", "sources": [ { "db": "NVD", "id": "CVE-2020-28400" }, { "db": "JVNDB", "id": "JVNDB-2021-010133" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-901" }, { "db": "VULMON", "id": "CVE-2020-28400" } ], "trust": 2.79 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-28400", "trust": 3.3 }, { "db": "ICS CERT", "id": "ICSA-21-194-03", "trust": 2.4 }, { "db": "SIEMENS", "id": "SSA-599968", "trust": 1.7 }, { "db": "JVNDB", "id": "JVNDB-2021-010133", "trust": 0.8 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2021.2401", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021071416", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202107-901", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2020-28400", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2020-28400" }, { "db": "JVNDB", "id": "JVNDB-2021-010133" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-901" }, { "db": "NVD", "id": "CVE-2020-28400" } ] }, "id": "VAR-202107-1608", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.5447269509677419 }, "last_update_date": "2024-08-14T12:06:49.974000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-599968", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf" }, { "title": "Siemens Various product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=156594" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=77fc0ba2dcd8966c9a1f7eb47b8603ca" } ], "sources": [ { "db": "VULMON", "id": "CVE-2020-28400" }, { "db": "JVNDB", "id": "JVNDB-2021-010133" }, { "db": "CNNVD", "id": "CNNVD-202107-901" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-770", "trust": 1.0 }, { "problemtype": "Allocation of resources without limits or throttling (CWE-770) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-010133" }, { "db": "NVD", "id": "CVE-2020-28400" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.2, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf" }, { "trust": 1.0, "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-28400" }, { "trust": 0.8, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-194-03" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/siemens-ruggedcom-simatic-denial-of-service-via-profinet-dcp-reset-35890" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021071416" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2021.2401" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/770.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://cert-portal.siemens.com/productcert/txt/ssa-599968.txt" } ], "sources": [ { "db": "VULMON", "id": "CVE-2020-28400" }, { "db": "JVNDB", "id": "JVNDB-2021-010133" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-901" }, { "db": "NVD", "id": "CVE-2020-28400" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2020-28400" }, { "db": "JVNDB", "id": "JVNDB-2021-010133" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-901" }, { "db": "NVD", "id": "CVE-2020-28400" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-07-13T00:00:00", "db": "VULMON", "id": "CVE-2020-28400" }, { "date": "2022-06-22T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-010133" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-07-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202107-901" }, { "date": "2021-07-13T11:15:08.960000", "db": "NVD", "id": "CVE-2020-28400" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-07-13T00:00:00", "db": "VULMON", "id": "CVE-2020-28400" }, { "date": "2022-06-22T02:38:00", "db": "JVNDB", "id": "JVNDB-2021-010133" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2022-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202107-901" }, { "date": "2024-06-11T09:15:09.487000", "db": "NVD", "id": "CVE-2020-28400" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202107-901" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Vulnerability in limiting or non-slotting resource allocation in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-010133" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-901" } ], "trust": 1.2 } }
var-202207-0554
Vulnerability from variot
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2P IRT (All versions < V5.5.2), SCALANCE X202-2P IRT PRO (All versions < V5.5.2), SCALANCE X204-2 (All versions < V5.2.6), SCALANCE X204-2FM (All versions < V5.2.6), SCALANCE X204-2LD (All versions < V5.2.6), SCALANCE X204-2LD TS (All versions < V5.2.6), SCALANCE X204-2TS (All versions < V5.2.6), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT PRO (All versions < V5.5.2), SCALANCE X206-1 (All versions < V5.2.6), SCALANCE X206-1LD (All versions < V5.2.6), SCALANCE X208 (All versions < V5.2.6), SCALANCE X208PRO (All versions < V5.2.6), SCALANCE X212-2 (All versions < V5.2.6), SCALANCE X212-2LD (All versions < V5.2.6), SCALANCE X216 (All versions < V5.2.6), SCALANCE X224 (All versions < V5.2.6), SCALANCE XF201-3P IRT (All versions < V5.5.2), SCALANCE XF202-2P IRT (All versions < V5.5.2), SCALANCE XF204 (All versions < V5.2.6), SCALANCE XF204-2 (All versions < V5.2.6), SCALANCE XF204-2BA IRT (All versions < V5.5.2), SCALANCE XF204IRT (All versions < V5.5.2), SCALANCE XF206-1 (All versions < V5.2.6), SCALANCE XF208 (All versions < V5.2.6). Affected devices do not properly validate the GET parameter XNo of incoming HTTP requests. This could allow an unauthenticated remote attacker to crash affected devices. SCALANCE X204-2 firmware, SCALANCE X204-2FM firmware, SCALANCE X204-2LD Multiple Siemens products, such as firmware, contain a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Siemens SCALANCE X Switches is an industrial Ethernet switch product from Siemens (Siemens) in Germany
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202207-0554", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "scalance x204-2fm", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x204-2ld", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x204-2ld ts", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x204-2ts", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x206-1ld", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x212-2ld", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance xf204", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance xf204-2", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance xf206-1", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance xf208", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x200-4p irt", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x201-3p irt", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x201-3p irt pro", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x202-2irt", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x202-2p irt", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x202-2p irt pro", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x204irt", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x204irt pro", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance xf204irt", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x202-2p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x206-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x200-4p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x201-3p irt pro", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x202-2irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204-2ba irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x208 pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x212-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance xf201-3p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x204-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x208", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x204irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x204irt pro", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x224", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x216", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance xf202-2p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x202-2p irt pro", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x201-3p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x212-2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x204-2ld", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xf204", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x204-2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x206-1ld", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x208", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xf204-2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x204-2fm", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x200-4p irt", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x204-2ld ts", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x208 pro", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x216", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x204-2ts", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xf208", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x206-1", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x224", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x201-3p irt", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x212-2ld", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x201-3p irt pro", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xf206-1", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x204-2\u003c5.2.6" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x206-1\u003c5.2.6" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x208\u003c5.2.6" }, { "model": "scalance x208pro", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x212-2\u003c5.2.6" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x216\u003c5.2.6" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x224\u003c5.2.6" }, { "model": "scalance xf201-3p irt", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xf202-2p irt", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xf204-2ba irt", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-51439" }, { "db": "JVNDB", "id": "JVNDB-2022-013160" }, { "db": "NVD", "id": "CVE-2022-26648" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202207-942" } ], "trust": 0.6 }, "cve": "CVE-2022-26648", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2022-26648", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CNVD-2022-51439", "impactScore": 8.5, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2022-26648", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "productcert@siemens.com", "availabilityImpact": "HIGH", "baseScore": 8.2, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "exploitabilityScore": 2.3, "id": "CVE-2022-26648", "impactScore": 5.3, "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 8.2, "baseSeverity": "High", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2022-013160", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "Low", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-26648", "trust": 1.0, "value": "HIGH" }, { "author": "productcert@siemens.com", "id": "CVE-2022-26648", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2022-26648", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2022-51439", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202207-942", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2022-26648", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-51439" }, { "db": "VULMON", "id": "CVE-2022-26648" }, { "db": "JVNDB", "id": "JVNDB-2022-013160" }, { "db": "CNNVD", "id": "CNNVD-202207-942" }, { "db": "NVD", "id": "CVE-2022-26648" }, { "db": "NVD", "id": "CVE-2022-26648" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT PRO (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT PRO (All versions \u003c V5.5.2), SCALANCE X204-2 (All versions \u003c V5.2.6), SCALANCE X204-2FM (All versions \u003c V5.2.6), SCALANCE X204-2LD (All versions \u003c V5.2.6), SCALANCE X204-2LD TS (All versions \u003c V5.2.6), SCALANCE X204-2TS (All versions \u003c V5.2.6), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT PRO (All versions \u003c V5.5.2), SCALANCE X206-1 (All versions \u003c V5.2.6), SCALANCE X206-1LD (All versions \u003c V5.2.6), SCALANCE X208 (All versions \u003c V5.2.6), SCALANCE X208PRO (All versions \u003c V5.2.6), SCALANCE X212-2 (All versions \u003c V5.2.6), SCALANCE X212-2LD (All versions \u003c V5.2.6), SCALANCE X216 (All versions \u003c V5.2.6), SCALANCE X224 (All versions \u003c V5.2.6), SCALANCE XF201-3P IRT (All versions \u003c V5.5.2), SCALANCE XF202-2P IRT (All versions \u003c V5.5.2), SCALANCE XF204 (All versions \u003c V5.2.6), SCALANCE XF204-2 (All versions \u003c V5.2.6), SCALANCE XF204-2BA IRT (All versions \u003c V5.5.2), SCALANCE XF204IRT (All versions \u003c V5.5.2), SCALANCE XF206-1 (All versions \u003c V5.2.6), SCALANCE XF208 (All versions \u003c V5.2.6). Affected devices do not properly validate the GET parameter XNo of incoming HTTP requests. This could allow an unauthenticated remote attacker to crash affected devices. SCALANCE X204-2 firmware, SCALANCE X204-2FM firmware, SCALANCE X204-2LD Multiple Siemens products, such as firmware, contain a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Siemens SCALANCE X Switches is an industrial Ethernet switch product from Siemens (Siemens) in Germany", "sources": [ { "db": "NVD", "id": "CVE-2022-26648" }, { "db": "JVNDB", "id": "JVNDB-2022-013160" }, { "db": "CNVD", "id": "CNVD-2022-51439" }, { "db": "VULMON", "id": "CVE-2022-26648" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-26648", "trust": 3.9 }, { "db": "SIEMENS", "id": "SSA-310038", "trust": 3.1 }, { "db": "ICS CERT", "id": "ICSA-22-195-01", "trust": 1.5 }, { "db": "JVN", "id": "JVNVU97764115", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2022-013160", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2022-51439", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2022071408", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202207-942", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2022-26648", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-51439" }, { "db": "VULMON", "id": "CVE-2022-26648" }, { "db": "JVNDB", "id": "JVNDB-2022-013160" }, { "db": "CNNVD", "id": "CNNVD-202207-942" }, { "db": "NVD", "id": "CVE-2022-26648" } ] }, "id": "VAR-202207-0554", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2022-51439" } ], "trust": 1.1104343616666665 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-51439" } ] }, "last_update_date": "2024-08-14T13:42:36.659000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens SCALANCE X Switches Buffer Overflow Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/339431" }, { "title": "Siemens SCALANCE Security vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=232913" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-51439" }, { "db": "CNNVD", "id": "CNNVD-202207-942" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-120", "trust": 1.0 }, { "problemtype": "Classic buffer overflow (CWE-120) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-013160" }, { "db": "NVD", "id": "CVE-2022-26648" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-310038.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu97764115/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-26648" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-195-01" }, { "trust": 0.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-310038.html" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-26648/" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2022071408" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-195-01" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/120.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-195-01" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-51439" }, { "db": "VULMON", "id": "CVE-2022-26648" }, { "db": "JVNDB", "id": "JVNDB-2022-013160" }, { "db": "CNNVD", "id": "CNNVD-202207-942" }, { "db": "NVD", "id": "CVE-2022-26648" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2022-51439" }, { "db": "VULMON", "id": "CVE-2022-26648" }, { "db": "JVNDB", "id": "JVNDB-2022-013160" }, { "db": "CNNVD", "id": "CNNVD-202207-942" }, { "db": "NVD", "id": "CVE-2022-26648" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-07-14T00:00:00", "db": "CNVD", "id": "CNVD-2022-51439" }, { "date": "2022-07-12T00:00:00", "db": "VULMON", "id": "CVE-2022-26648" }, { "date": "2023-09-05T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-013160" }, { "date": "2022-07-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202207-942" }, { "date": "2022-07-12T10:15:10.313000", "db": "NVD", "id": "CVE-2022-26648" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-07-14T00:00:00", "db": "CNVD", "id": "CNVD-2022-51439" }, { "date": "2022-07-15T00:00:00", "db": "VULMON", "id": "CVE-2022-26648" }, { "date": "2023-10-20T07:00:00", "db": "JVNDB", "id": "JVNDB-2022-013160" }, { "date": "2023-04-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202207-942" }, { "date": "2023-04-11T10:15:14.190000", "db": "NVD", "id": "CVE-2022-26648" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202207-942" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Classic buffer overflow vulnerability in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-013160" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202207-942" } ], "trust": 0.6 } }
var-202207-0556
Vulnerability from variot
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2P IRT (All versions < V5.5.2), SCALANCE X202-2P IRT PRO (All versions < V5.5.2), SCALANCE X204-2 (All versions < V5.2.6), SCALANCE X204-2FM (All versions < V5.2.6), SCALANCE X204-2LD (All versions < V5.2.6), SCALANCE X204-2LD TS (All versions < V5.2.6), SCALANCE X204-2TS (All versions < V5.2.6), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT PRO (All versions < V5.5.2), SCALANCE X206-1 (All versions < V5.2.6), SCALANCE X206-1LD (All versions < V5.2.6), SCALANCE X208 (All versions < V5.2.6), SCALANCE X208PRO (All versions < V5.2.6), SCALANCE X212-2 (All versions < V5.2.6), SCALANCE X212-2LD (All versions < V5.2.6), SCALANCE X216 (All versions < V5.2.6), SCALANCE X224 (All versions < V5.2.6), SCALANCE XF201-3P IRT (All versions < V5.5.2), SCALANCE XF202-2P IRT (All versions < V5.5.2), SCALANCE XF204 (All versions < V5.2.6), SCALANCE XF204-2 (All versions < V5.2.6), SCALANCE XF204-2BA IRT (All versions < V5.5.2), SCALANCE XF204IRT (All versions < V5.5.2), SCALANCE XF206-1 (All versions < V5.2.6), SCALANCE XF208 (All versions < V5.2.6). Affected devices do not properly validate the URI of incoming HTTP GET requests. This could allow an unauthenticated remote attacker to crash affected devices. Siemens SCALANCE X Switches is an industrial Ethernet switch product from Siemens (Siemens) in Germany
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202207-0556", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "scalance x204-2fm", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x204-2ld", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x204-2ld ts", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x204-2ts", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x206-1ld", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x212-2ld", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance xf204", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance xf204-2", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance xf206-1", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance xf208", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x200-4p irt", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x201-3p irt", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x201-3p irt pro", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x202-2irt", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x202-2p irt", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x202-2p irt pro", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x204irt", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x204irt pro", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance xf204irt", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x202-2p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x206-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x200-4p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x201-3p irt pro", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x202-2irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204-2ba irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x208 pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x212-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance xf201-3p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x204-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x208", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x204irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x204irt pro", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x224", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x216", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance xf202-2p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x202-2p irt pro", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x201-3p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x204-2\u003c5.2.6" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x206-1\u003c5.2.6" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x208\u003c5.2.6" }, { "model": "scalance x208pro", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x212-2\u003c5.2.6" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x216\u003c5.2.6" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x224\u003c5.2.6" }, { "model": "scalance xf201-3p irt", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xf202-2p irt", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xf204-2ba irt", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-51438" }, { "db": "NVD", "id": "CVE-2022-26649" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202207-940" } ], "trust": 0.6 }, "cve": "CVE-2022-26649", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2022-26649", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 1.1, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 6.5, "id": "CNVD-2022-51438", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2022-26649", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "productcert@siemens.com", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2022-26649", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-26649", "trust": 1.0, "value": "HIGH" }, { "author": "productcert@siemens.com", "id": "CVE-2022-26649", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2022-51438", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202207-940", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2022-26649", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-51438" }, { "db": "VULMON", "id": "CVE-2022-26649" }, { "db": "CNNVD", "id": "CNNVD-202207-940" }, { "db": "NVD", "id": "CVE-2022-26649" }, { "db": "NVD", "id": "CVE-2022-26649" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT PRO (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT PRO (All versions \u003c V5.5.2), SCALANCE X204-2 (All versions \u003c V5.2.6), SCALANCE X204-2FM (All versions \u003c V5.2.6), SCALANCE X204-2LD (All versions \u003c V5.2.6), SCALANCE X204-2LD TS (All versions \u003c V5.2.6), SCALANCE X204-2TS (All versions \u003c V5.2.6), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT PRO (All versions \u003c V5.5.2), SCALANCE X206-1 (All versions \u003c V5.2.6), SCALANCE X206-1LD (All versions \u003c V5.2.6), SCALANCE X208 (All versions \u003c V5.2.6), SCALANCE X208PRO (All versions \u003c V5.2.6), SCALANCE X212-2 (All versions \u003c V5.2.6), SCALANCE X212-2LD (All versions \u003c V5.2.6), SCALANCE X216 (All versions \u003c V5.2.6), SCALANCE X224 (All versions \u003c V5.2.6), SCALANCE XF201-3P IRT (All versions \u003c V5.5.2), SCALANCE XF202-2P IRT (All versions \u003c V5.5.2), SCALANCE XF204 (All versions \u003c V5.2.6), SCALANCE XF204-2 (All versions \u003c V5.2.6), SCALANCE XF204-2BA IRT (All versions \u003c V5.5.2), SCALANCE XF204IRT (All versions \u003c V5.5.2), SCALANCE XF206-1 (All versions \u003c V5.2.6), SCALANCE XF208 (All versions \u003c V5.2.6). Affected devices do not properly validate the URI of incoming HTTP GET requests. This could allow an unauthenticated remote attacker to crash affected devices. Siemens SCALANCE X Switches is an industrial Ethernet switch product from Siemens (Siemens) in Germany", "sources": [ { "db": "NVD", "id": "CVE-2022-26649" }, { "db": "CNVD", "id": "CNVD-2022-51438" }, { "db": "VULMON", "id": "CVE-2022-26649" } ], "trust": 1.53 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-26649", "trust": 2.3 }, { "db": "SIEMENS", "id": "SSA-310038", "trust": 2.3 }, { "db": "ICS CERT", "id": "ICSA-22-195-01", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2022-51438", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2022071408", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202207-940", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2022-26649", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-51438" }, { "db": "VULMON", "id": "CVE-2022-26649" }, { "db": "CNNVD", "id": "CNNVD-202207-940" }, { "db": "NVD", "id": "CVE-2022-26649" } ] }, "id": "VAR-202207-0556", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2022-51438" } ], "trust": 1.1104343616666665 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-51438" } ] }, "last_update_date": "2024-08-14T13:42:36.991000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens SCALANCE X Switches Buffer Overflow Vulnerability (CNVD-2022-51438)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/339441" }, { "title": "Multiple Siemens SCALANCE Product security vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=232912" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-51438" }, { "db": "CNNVD", "id": "CNNVD-202207-940" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-120", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2022-26649" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-310038.pdf" }, { "trust": 0.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-310038.html" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-26649/" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2022071408" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-195-01" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/120.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-195-01" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-51438" }, { "db": "VULMON", "id": "CVE-2022-26649" }, { "db": "CNNVD", "id": "CNNVD-202207-940" }, { "db": "NVD", "id": "CVE-2022-26649" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2022-51438" }, { "db": "VULMON", "id": "CVE-2022-26649" }, { "db": "CNNVD", "id": "CNNVD-202207-940" }, { "db": "NVD", "id": "CVE-2022-26649" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-07-14T00:00:00", "db": "CNVD", "id": "CNVD-2022-51438" }, { "date": "2022-07-12T00:00:00", "db": "VULMON", "id": "CVE-2022-26649" }, { "date": "2022-07-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202207-940" }, { "date": "2022-07-12T10:15:10.367000", "db": "NVD", "id": "CVE-2022-26649" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-07-14T00:00:00", "db": "CNVD", "id": "CNVD-2022-51438" }, { "date": "2022-07-15T00:00:00", "db": "VULMON", "id": "CVE-2022-26649" }, { "date": "2023-04-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202207-940" }, { "date": "2023-04-11T10:15:14.387000", "db": "NVD", "id": "CVE-2022-26649" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202207-940" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens SCALANCE X Switches Buffer Overflow Vulnerability (CNVD-2022-51438)", "sources": [ { "db": "CNVD", "id": "CNVD-2022-51438" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202207-940" } ], "trust": 0.6 } }
var-202207-0555
Vulnerability from variot
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2P IRT (All versions < V5.5.2), SCALANCE X202-2P IRT PRO (All versions < V5.5.2), SCALANCE X204-2 (All versions < V5.2.6), SCALANCE X204-2FM (All versions < V5.2.6), SCALANCE X204-2LD (All versions < V5.2.6), SCALANCE X204-2LD TS (All versions < V5.2.6), SCALANCE X204-2TS (All versions < V5.2.6), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT PRO (All versions < V5.5.2), SCALANCE X206-1 (All versions < V5.2.6), SCALANCE X206-1LD (All versions < V5.2.6), SCALANCE X208 (All versions < V5.2.6), SCALANCE X208PRO (All versions < V5.2.6), SCALANCE X212-2 (All versions < V5.2.6), SCALANCE X212-2LD (All versions < V5.2.6), SCALANCE X216 (All versions < V5.2.6), SCALANCE X224 (All versions < V5.2.6), SCALANCE XF201-3P IRT (All versions < V5.5.2), SCALANCE XF202-2P IRT (All versions < V5.5.2), SCALANCE XF204 (All versions < V5.2.6), SCALANCE XF204-2 (All versions < V5.2.6), SCALANCE XF204-2BA IRT (All versions < V5.5.2), SCALANCE XF204IRT (All versions < V5.5.2), SCALANCE XF206-1 (All versions < V5.2.6), SCALANCE XF208 (All versions < V5.2.6). The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions. Siemens SCALANCE X Switches is an industrial Ethernet switch product from Siemens (Siemens) in Germany
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202207-0555", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "scalance x204-2fm", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x204-2ld", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x204-2ld ts", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x204-2ts", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x206-1ld", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x212-2ld", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance xf204", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance xf204-2", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance xf206-1", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance xf208", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x200-4p irt", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x201-3p irt", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x201-3p irt pro", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x202-2irt", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x202-2p irt", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x202-2p irt pro", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x204irt", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x204irt pro", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance xf204irt", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x202-2p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x206-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x200-4p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x201-3p irt pro", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x202-2irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204-2ba irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x208 pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x212-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance xf201-3p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x204-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x208", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x204irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x204irt pro", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x224", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x216", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance xf202-2p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x202-2p irt pro", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x201-3p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x204-2\u003c5.2.6" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x206-1\u003c5.2.6" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x208\u003c5.2.6" }, { "model": "scalance x208pro", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x212-2\u003c5.2.6" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x216\u003c5.2.6" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x224\u003c5.2.6" }, { "model": "scalance xf201-3p irt", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xf202-2p irt", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xf204-2ba irt", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-51440" }, { "db": "NVD", "id": "CVE-2022-26647" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202207-950" } ], "trust": 0.6 }, "cve": "CVE-2022-26647", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2022-26647", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.1, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2022-51440", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2022-26647", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "productcert@siemens.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2022-26647", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-26647", "trust": 1.0, "value": "CRITICAL" }, { "author": "productcert@siemens.com", "id": "CVE-2022-26647", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2022-51440", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202207-950", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2022-26647", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-51440" }, { "db": "VULMON", "id": "CVE-2022-26647" }, { "db": "CNNVD", "id": "CNNVD-202207-950" }, { "db": "NVD", "id": "CVE-2022-26647" }, { "db": "NVD", "id": "CVE-2022-26647" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT PRO (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT PRO (All versions \u003c V5.5.2), SCALANCE X204-2 (All versions \u003c V5.2.6), SCALANCE X204-2FM (All versions \u003c V5.2.6), SCALANCE X204-2LD (All versions \u003c V5.2.6), SCALANCE X204-2LD TS (All versions \u003c V5.2.6), SCALANCE X204-2TS (All versions \u003c V5.2.6), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT PRO (All versions \u003c V5.5.2), SCALANCE X206-1 (All versions \u003c V5.2.6), SCALANCE X206-1LD (All versions \u003c V5.2.6), SCALANCE X208 (All versions \u003c V5.2.6), SCALANCE X208PRO (All versions \u003c V5.2.6), SCALANCE X212-2 (All versions \u003c V5.2.6), SCALANCE X212-2LD (All versions \u003c V5.2.6), SCALANCE X216 (All versions \u003c V5.2.6), SCALANCE X224 (All versions \u003c V5.2.6), SCALANCE XF201-3P IRT (All versions \u003c V5.5.2), SCALANCE XF202-2P IRT (All versions \u003c V5.5.2), SCALANCE XF204 (All versions \u003c V5.2.6), SCALANCE XF204-2 (All versions \u003c V5.2.6), SCALANCE XF204-2BA IRT (All versions \u003c V5.5.2), SCALANCE XF204IRT (All versions \u003c V5.5.2), SCALANCE XF206-1 (All versions \u003c V5.2.6), SCALANCE XF208 (All versions \u003c V5.2.6). The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions. Siemens SCALANCE X Switches is an industrial Ethernet switch product from Siemens (Siemens) in Germany", "sources": [ { "db": "NVD", "id": "CVE-2022-26647" }, { "db": "CNVD", "id": "CNVD-2022-51440" }, { "db": "VULMON", "id": "CVE-2022-26647" } ], "trust": 1.53 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-26647", "trust": 2.3 }, { "db": "SIEMENS", "id": "SSA-310038", "trust": 2.3 }, { "db": "ICS CERT", "id": "ICSA-22-195-01", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2022-51440", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2022071408", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202207-950", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2022-26647", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-51440" }, { "db": "VULMON", "id": "CVE-2022-26647" }, { "db": "CNNVD", "id": "CNNVD-202207-950" }, { "db": "NVD", "id": "CVE-2022-26647" } ] }, "id": "VAR-202207-0555", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2022-51440" } ], "trust": 1.1104343616666665 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-51440" } ] }, "last_update_date": "2024-08-14T13:42:37.019000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Unknown Vulnerability in Siemens SCALANCE X Switches", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/339406" }, { "title": "Siemens SCALANCE Security Feature Issues Feature Issues Vulnerabilities Repair Measures", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=232914" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-51440" }, { "db": "CNNVD", "id": "CNNVD-202207-950" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-330", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2022-26647" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-310038.pdf" }, { "trust": 0.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-310038.html" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-26647/" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2022071408" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-195-01" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/330.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-195-01" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-51440" }, { "db": "VULMON", "id": "CVE-2022-26647" }, { "db": "CNNVD", "id": "CNNVD-202207-950" }, { "db": "NVD", "id": "CVE-2022-26647" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2022-51440" }, { "db": "VULMON", "id": "CVE-2022-26647" }, { "db": "CNNVD", "id": "CNNVD-202207-950" }, { "db": "NVD", "id": "CVE-2022-26647" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-07-14T00:00:00", "db": "CNVD", "id": "CNVD-2022-51440" }, { "date": "2022-07-12T00:00:00", "db": "VULMON", "id": "CVE-2022-26647" }, { "date": "2022-07-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202207-950" }, { "date": "2022-07-12T10:15:10.257000", "db": "NVD", "id": "CVE-2022-26647" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-07-14T00:00:00", "db": "CNVD", "id": "CNVD-2022-51440" }, { "date": "2022-07-15T00:00:00", "db": "VULMON", "id": "CVE-2022-26647" }, { "date": "2023-04-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202207-950" }, { "date": "2023-04-11T10:15:13.657000", "db": "NVD", "id": "CVE-2022-26647" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202207-950" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Unknown Vulnerability in Siemens SCALANCE X Switches", "sources": [ { "db": "CNVD", "id": "CNVD-2022-51440" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "security feature problem", "sources": [ { "db": "CNNVD", "id": "CNNVD-202207-950" } ], "trust": 0.6 } }
var-202104-1057
Vulnerability from variot
An issue was discovered in Wind River VxWorks before 6.5. There is a possible heap overflow in dhcp client. Wind River VxWorks Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202104-1057", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "scalance x204 irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics perfect harmony gh180", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2022" }, { "model": "scalance xf204-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x224", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x208 pro", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x200-4 p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x204 irt pro", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x216", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf206-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x212-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x201-3p irt pro", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x204-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204 irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic rf 182c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "vxworks", "scope": "lt", "trust": 1.0, "vendor": "windriver", "version": "6.5" }, { "model": "scalance x408", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x208", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf202-2p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x202-2p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf208", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic rf 181 eip", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x206-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x204-2ld", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x204-2ld ts", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x202-2p irt pro", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x204-2ts", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x300", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x201-3p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x206-1ld", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "ruggedcom win subscriber station", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics perfect harmony gh180", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "2015" }, { "model": "scalance xf204-2ba irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x212-2ld", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x204-2fm", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x202-2 irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf201-3p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "vxworks", "scope": "eq", "trust": 0.8, "vendor": "\u30a6\u30a4\u30f3\u30c9\u30ea\u30d0\u30fc\u682a\u5f0f\u4f1a\u793e", "version": null }, { "model": "vxworks", "scope": "eq", "trust": 0.8, "vendor": "\u30a6\u30a4\u30f3\u30c9\u30ea\u30d0\u30fc\u682a\u5f0f\u4f1a\u793e", "version": "6.5" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-005466" }, { "db": "NVD", "id": "CVE-2021-29998" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Mitsubishi Electric reported this vulnerability to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-915" } ], "trust": 0.6 }, "cve": "CVE-2021-29998", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2021-29998", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-29998", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-29998", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-29998", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2021-29998", "trust": 0.8, "value": "Critical" }, { "author": "CNNVD", "id": "CNNVD-202104-915", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-29998", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29998" }, { "db": "JVNDB", "id": "JVNDB-2021-005466" }, { "db": "CNNVD", "id": "CNNVD-202104-915" }, { "db": "NVD", "id": "CVE-2021-29998" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An issue was discovered in Wind River VxWorks before 6.5. There is a possible heap overflow in dhcp client. Wind River VxWorks Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2021-29998" }, { "db": "JVNDB", "id": "JVNDB-2021-005466" }, { "db": "VULMON", "id": "CVE-2021-29998" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29998", "trust": 3.3 }, { "db": "ICS CERT", "id": "ICSA-21-194-12", "trust": 1.7 }, { "db": "SIEMENS", "id": "SSA-560465", "trust": 1.7 }, { "db": "SIEMENS", "id": "SSA-910883", "trust": 1.6 }, { "db": "ICS CERT", "id": "ICSA-22-102-02", "trust": 1.5 }, { "db": "JVN", "id": "JVNVU92475198", "trust": 0.8 }, { "db": "JVN", "id": "JVNVU97764115", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-005466", "trust": 0.8 }, { "db": "CS-HELP", "id": "SB2022071403", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2022041320", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-915", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29998", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29998" }, { "db": "JVNDB", "id": "JVNDB-2021-005466" }, { "db": "CNNVD", "id": "CNNVD-202104-915" }, { "db": "NVD", "id": "CVE-2021-29998" } ] }, "id": "VAR-202104-1057", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.46321214 }, "last_update_date": "2024-11-23T21:32:18.715000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "CVE-2021-29998", "trust": 0.8, "url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2021-29998" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=fc21b995a19e3c9e8671f01654bfbb04" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29998" }, { "db": "JVNDB", "id": "JVNDB-2021-005466" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-005466" }, { "db": "NVD", "id": "CVE-2021-29998" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://support2.windriver.com/index.php?page=security-notices" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-560465.pdf" }, { "trust": 1.7, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-12" }, { "trust": 1.6, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-910883.pdf" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29998" }, { "trust": 0.9, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-102-02" }, { "trust": 0.8, "url": "http://jvn.jp/vu/jvnvu92475198/index.html" }, { "trust": 0.8, "url": "http://jvn.jp/vu/jvnvu97764115/index.html" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-102-02" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/wind-river-vxworks-buffer-overflow-via-dhcp-client-35076" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2022041320" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2022071403" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/787.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29998" }, { "db": "JVNDB", "id": "JVNDB-2021-005466" }, { "db": "CNNVD", "id": "CNNVD-202104-915" }, { "db": "NVD", "id": "CVE-2021-29998" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29998" }, { "db": "JVNDB", "id": "JVNDB-2021-005466" }, { "db": "CNNVD", "id": "CNNVD-202104-915" }, { "db": "NVD", "id": "CVE-2021-29998" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-13T00:00:00", "db": "VULMON", "id": "CVE-2021-29998" }, { "date": "2021-12-14T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-005466" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-915" }, { "date": "2021-04-13T17:15:12.310000", "db": "NVD", "id": "CVE-2021-29998" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-04-22T00:00:00", "db": "VULMON", "id": "CVE-2021-29998" }, { "date": "2022-07-15T02:01:00", "db": "JVNDB", "id": "JVNDB-2021-005466" }, { "date": "2022-07-15T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-915" }, { "date": "2024-11-21T06:02:08.550000", "db": "NVD", "id": "CVE-2021-29998" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-915" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Wind\u00a0River\u00a0VxWorks\u00a0 Out-of-bounds write vulnerability in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-005466" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-915" } ], "trust": 0.6 } }
cve-2019-6569
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-557804.pdf | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:23:22.201Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-557804.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SCALANCE X204-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "product": "SCALANCE X204-2FM", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "product": "SCALANCE X204-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "product": "SCALANCE X204-2LD TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "product": "SCALANCE X204-2TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "product": "SCALANCE X206-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "product": "SCALANCE X206-1LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "product": "SCALANCE X208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "product": "SCALANCE X208PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "product": "SCALANCE X212-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "product": "SCALANCE X212-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "product": "SCALANCE X216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "product": "SCALANCE X224", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "product": "SCALANCE X302-7 EEC (230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X302-7 EEC (230V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X302-7 EEC (24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X302-7 EEC (24V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X302-7 EEC (2x 230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X302-7 EEC (2x 230V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X302-7 EEC (2x 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X302-7 EEC (2x 24V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X304-2FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X306-1LD FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X307-2 EEC (230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X307-2 EEC (230V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X307-2 EEC (24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X307-2 EEC (24V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X307-2 EEC (2x 230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X307-2 EEC (2x 230V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X307-2 EEC (2x 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X307-2 EEC (2x 24V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X307-3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X307-3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X307-3LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X307-3LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X308-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X308-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X308-2LH", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X308-2LH", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X308-2LH+", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X308-2LH+", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X308-2M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X308-2M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X308-2M PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X308-2M PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X308-2M TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X308-2M TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X310", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X310", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X310FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X310FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X320-1 FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X320-1-2LD FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X408-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XB205-3 (SC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XB205-3 (SC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XB205-3 (ST/BFOC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XB205-3 (ST/BFOC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XB205-3LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XB205-3LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XB208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XB208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XB213-3 (SC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XB213-3 (SC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XB213-3 (ST/BFOC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XB213-3 (ST/BFOC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XB213-3LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XB213-3LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XB216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XB216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XC206-2 (SC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XC206-2 (ST/BFOC)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XC206-2SFP EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XC206-2SFP G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XC206-2SFP G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XC206-2SFP G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XC208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XC208EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XC208G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XC208G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XC208G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XC216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XC216-4C G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XC216-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XC216-4C G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XC216EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XC224", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XC224-4C G", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XC224-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XC224-4C G EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XF204 DNA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XF204-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "product": "SCALANCE XF204-2BA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XF204-2BA DNA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XF206-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "product": "SCALANCE XF208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "product": "SCALANCE XP208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XP208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XP208EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XP208PoE EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XP216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XP216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XP216EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XP216POE EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XR324-12M (230V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-12M (230V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-12M (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-12M (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-12M (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-12M (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-12M (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-12M (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-12M TS (24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-12M TS (24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-4M EEC (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-4M EEC (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-4M EEC (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-4M EEC (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-4M PoE (230V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-4M PoE (230V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-4M PoE (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-4M PoE (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-4M PoE (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-4M PoE (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-4M PoE (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-4M PoE (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE XR324WG (24 X FE, DC 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XR324WG (24 x FE, AC 230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SIPLUS NET SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SIPLUS NET SCALANCE XC206-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SIPLUS NET SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SIPLUS NET SCALANCE XC208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SIPLUS NET SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] } ], "datePublic": "2019-03-12T00:00:00", "descriptions": [ { "lang": "en", "value": "The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-440", "description": "CWE-440: Expected Behavior Violation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-07-12T10:06:21", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-557804.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-6569", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SCALANCE X204-2", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.6" } ] } }, { "product_name": "SCALANCE X204-2FM", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.6" } ] } }, { "product_name": "SCALANCE X204-2LD", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.6" } ] } }, { "product_name": "SCALANCE X204-2LD TS", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.6" } ] } }, { "product_name": "SCALANCE X204-2TS", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.6" } ] } }, { "product_name": "SCALANCE X206-1", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.6" } ] } }, { "product_name": "SCALANCE X206-1LD", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.6" } ] } }, { "product_name": "SCALANCE X208", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.6" } ] } }, { "product_name": "SCALANCE X208PRO", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.6" } ] } }, { "product_name": "SCALANCE X212-2", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.6" } ] } }, { "product_name": "SCALANCE X212-2LD", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.6" } ] } }, { "product_name": "SCALANCE X216", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.6" } ] } }, { "product_name": "SCALANCE X224", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.6" } ] } }, { "product_name": "SCALANCE X302-7 EEC (230V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X302-7 EEC (230V, coated)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X302-7 EEC (24V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X302-7 EEC (24V, coated)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X302-7 EEC (2x 230V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X302-7 EEC (2x 230V, coated)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X302-7 EEC (2x 24V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X302-7 EEC (2x 24V, coated)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X304-2FE", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X306-1LD FE", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X307-2 EEC (230V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X307-2 EEC (230V, coated)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X307-2 EEC (24V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X307-2 EEC (24V, coated)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X307-2 EEC (2x 230V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X307-2 EEC (2x 230V, coated)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X307-2 EEC (2x 24V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X307-2 EEC (2x 24V, coated)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X307-3", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X307-3", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X307-3LD", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X307-3LD", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X308-2", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X308-2", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X308-2LD", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X308-2LD", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X308-2LH", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X308-2LH", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X308-2LH+", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X308-2LH+", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X308-2M", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X308-2M", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X308-2M PoE", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X308-2M PoE", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X308-2M TS", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X308-2M TS", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X310", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X310", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X310FE", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X310FE", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X320-1 FE", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X320-1-2LD FE", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X408-2", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XB205-3 (SC)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XB205-3 (SC)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XB205-3 (ST/BFOC)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XB205-3 (ST/BFOC)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XB205-3LD", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XB205-3LD", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XB208", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XB208", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XB213-3 (SC)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XB213-3 (SC)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XB213-3 (ST/BFOC)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XB213-3 (ST/BFOC)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XB213-3LD", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XB213-3LD", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XB216", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XB216", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XC206-2 (SC)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XC206-2 (ST/BFOC)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XC206-2SFP", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XC206-2SFP EEC", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XC206-2SFP G", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XC206-2SFP G", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XC206-2SFP G EEC", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XC208", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XC208EEC", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XC208G", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XC208G", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XC208G EEC", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XC216", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XC216-4C", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XC216-4C G", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XC216-4C G (EIP Def.)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XC216-4C G EEC", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XC216EEC", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XC224", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XC224-4C G", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XC224-4C G (EIP Def.)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XC224-4C G EEC", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XF204", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.6" } ] } }, { "product_name": "SCALANCE XF204", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XF204 DNA", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XF204-2", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.6" } ] } }, { "product_name": "SCALANCE XF204-2BA", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XF204-2BA DNA", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XF206-1", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.6" } ] } }, { "product_name": "SCALANCE XF208", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.6" } ] } }, { "product_name": "SCALANCE XP208", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XP208", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XP208EEC", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XP208PoE EEC", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XP216", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XP216", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XP216EEC", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XP216POE EEC", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XR324-12M (230V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-12M (230V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-12M (230V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-12M (230V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-12M (24V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-12M (24V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-12M (24V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-12M (24V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-12M TS (24V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-12M TS (24V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-4M PoE (230V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-4M PoE (230V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-4M PoE (230V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-4M PoE (230V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-4M PoE (24V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-4M PoE (24V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-4M PoE (24V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-4M PoE (24V, ports on rear)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-4M PoE TS (24V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324-4M PoE TS (24V, ports on front)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE XR324WG (24 X FE, DC 24V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XR324WG (24 x FE, AC 230V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XR328-4C WG (28xGE, AC 230V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XR328-4C WG (28xGE, DC 24V)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SIPLUS NET SCALANCE X308-2", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SIPLUS NET SCALANCE XC206-2", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SIPLUS NET SCALANCE XC206-2SFP", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SIPLUS NET SCALANCE XC208", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SIPLUS NET SCALANCE XC216-4C", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-440: Expected Behavior Violation" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-557804.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-557804.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-6569", "datePublished": "2019-03-26T21:12:43", "dateReserved": "2019-01-22T00:00:00", "dateUpdated": "2024-08-04T20:23:22.201Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-40631
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SCALANCE X200-4P IRT |
Version: All versions < V5.5.0 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T12:21:46.592Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-501891.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SCALANCE X200-4P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X201-3P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X202-2IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X202-2P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X204-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X204-2FM", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X204-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X204-2LD TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X204-2TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X204IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X206-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X206-1LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X208PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X212-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X212-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X224", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE XF201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE XF202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE XF204-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE XF204-2BA IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE XF204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE XF206-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE XF208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SIPLUS NET SCALANCE X202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c V5.5.0), SCALANCE X201-3P IRT (All versions \u003c V5.5.0), SCALANCE X201-3P IRT PRO (All versions \u003c V5.5.0), SCALANCE X202-2IRT (All versions \u003c V5.5.0), SCALANCE X202-2P IRT (All versions \u003c V5.5.0), SCALANCE X202-2P IRT PRO (All versions \u003c V5.5.0), SCALANCE X204-2 (All versions \u003c V5.2.5), SCALANCE X204-2FM (All versions \u003c V5.2.5), SCALANCE X204-2LD (All versions \u003c V5.2.5), SCALANCE X204-2LD TS (All versions \u003c V5.2.5), SCALANCE X204-2TS (All versions \u003c V5.2.5), SCALANCE X204IRT (All versions \u003c V5.5.0), SCALANCE X204IRT PRO (All versions \u003c V5.5.0), SCALANCE X206-1 (All versions \u003c V5.2.5), SCALANCE X206-1LD (All versions \u003c V5.2.5), SCALANCE X208 (All versions \u003c V5.2.5), SCALANCE X208PRO (All versions \u003c V5.2.5), SCALANCE X212-2 (All versions \u003c V5.2.5), SCALANCE X212-2LD (All versions \u003c V5.2.5), SCALANCE X216 (All versions \u003c V5.2.5), SCALANCE X224 (All versions \u003c V5.2.5), SCALANCE XF201-3P IRT (All versions \u003c V5.5.0), SCALANCE XF202-2P IRT (All versions \u003c V5.5.0), SCALANCE XF204 (All versions \u003c V5.2.5), SCALANCE XF204-2 (All versions \u003c V5.2.5), SCALANCE XF204-2BA IRT (All versions \u003c V5.5.0), SCALANCE XF204IRT (All versions \u003c V5.5.0), SCALANCE XF206-1 (All versions \u003c V5.2.5), SCALANCE XF208 (All versions \u003c V5.2.5), SIPLUS NET SCALANCE X202-2P IRT (All versions \u003c V5.5.0). There is a cross-site scripting vulnerability on the affected devices, that if used by a threat actor, it could result in session hijacking." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-10-11T00:00:00", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-501891.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-40631", "datePublished": "2022-10-11T00:00:00", "dateReserved": "2022-09-13T00:00:00", "dateUpdated": "2024-08-03T12:21:46.592Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-19301
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SCALANCE X200-4P IRT |
Version: All versions < V5.5.0 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:16:46.705Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-102233.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SCALANCE X200-4P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2FM", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2LD TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X206-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X206-1LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X208PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X212-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X212-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X224", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (230V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (24V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 230V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 24V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X304-2FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X306-1LD FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (230V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (24V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 230V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 24V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH+", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH+", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X320-1 FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X320-1-2LD FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X408-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF206-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M TS (24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M TS (24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (230V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 442-1 RNA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.5.18" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 RNA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.5.18" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF180C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF182C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET CP 343-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET CP 443-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET CP 443-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2IRT, SCALANCE X202-2P IRT, SCALANCE X202-2P IRT PRO, SCALANCE X204-2, SCALANCE X204-2FM, SCALANCE X204-2LD, SCALANCE X204-2LD TS, SCALANCE X204-2TS, SCALANCE X204IRT, SCALANCE X204IRT PRO, SCALANCE X206-1, SCALANCE X206-1LD, SCALANCE X208, SCALANCE X208PRO, SCALANCE X212-2, SCALANCE X212-2LD, SCALANCE X216, SCALANCE X224, SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XF201-3P IRT, SCALANCE XF202-2P IRT, SCALANCE XF204, SCALANCE XF204-2, SCALANCE XF204-2BA IRT, SCALANCE XF204IRT, SCALANCE XF206-1, SCALANCE XF208, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIMATIC CP 343-1 Advanced, SIMATIC CP 442-1 RNA, SIMATIC CP 443-1, SIMATIC CP 443-1, SIMATIC CP 443-1 Advanced, SIMATIC CP 443-1 RNA, SIMATIC RF180C, SIMATIC RF182C, SIPLUS NET CP 343-1 Advanced, SIPLUS NET CP 443-1, SIPLUS NET CP 443-1 Advanced, SIPLUS NET SCALANCE X308-2. The VxWorks-based Profinet TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:U/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-11T09:01:51.207Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-102233.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-19301", "datePublished": "2020-04-14T19:50:54", "dateReserved": "2019-11-26T00:00:00", "dateUpdated": "2024-08-05T02:16:46.705Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-26647
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SCALANCE X200-4P IRT |
Version: All versions < V5.5.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T05:11:43.345Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-310038.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SCALANCE X200-4P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2FM", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2LD TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X206-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X206-1LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X208PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X212-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X212-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X224", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF206-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT PRO (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT PRO (All versions \u003c V5.5.2), SCALANCE X204-2 (All versions \u003c V5.2.6), SCALANCE X204-2FM (All versions \u003c V5.2.6), SCALANCE X204-2LD (All versions \u003c V5.2.6), SCALANCE X204-2LD TS (All versions \u003c V5.2.6), SCALANCE X204-2TS (All versions \u003c V5.2.6), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT PRO (All versions \u003c V5.5.2), SCALANCE X206-1 (All versions \u003c V5.2.6), SCALANCE X206-1LD (All versions \u003c V5.2.6), SCALANCE X208 (All versions \u003c V5.2.6), SCALANCE X208PRO (All versions \u003c V5.2.6), SCALANCE X212-2 (All versions \u003c V5.2.6), SCALANCE X212-2LD (All versions \u003c V5.2.6), SCALANCE X216 (All versions \u003c V5.2.6), SCALANCE X224 (All versions \u003c V5.2.6), SCALANCE XF201-3P IRT (All versions \u003c V5.5.2), SCALANCE XF202-2P IRT (All versions \u003c V5.5.2), SCALANCE XF204 (All versions \u003c V5.2.6), SCALANCE XF204-2 (All versions \u003c V5.2.6), SCALANCE XF204-2BA IRT (All versions \u003c V5.5.2), SCALANCE XF204IRT (All versions \u003c V5.5.2), SCALANCE XF206-1 (All versions \u003c V5.2.6), SCALANCE XF208 (All versions \u003c V5.2.6). The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-330", "description": "CWE-330: Use of Insufficiently Random Values", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-11T09:02:19.204Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-310038.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-26647", "datePublished": "2022-07-12T10:06:32", "dateReserved": "2022-03-07T00:00:00", "dateUpdated": "2024-08-03T05:11:43.345Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-26649
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SCALANCE X200-4P IRT |
Version: All versions < V5.5.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T05:11:43.372Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-310038.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SCALANCE X200-4P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2FM", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2LD TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X206-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X206-1LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X208PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X212-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X212-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X224", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF206-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT PRO (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT PRO (All versions \u003c V5.5.2), SCALANCE X204-2 (All versions \u003c V5.2.6), SCALANCE X204-2FM (All versions \u003c V5.2.6), SCALANCE X204-2LD (All versions \u003c V5.2.6), SCALANCE X204-2LD TS (All versions \u003c V5.2.6), SCALANCE X204-2TS (All versions \u003c V5.2.6), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT PRO (All versions \u003c V5.5.2), SCALANCE X206-1 (All versions \u003c V5.2.6), SCALANCE X206-1LD (All versions \u003c V5.2.6), SCALANCE X208 (All versions \u003c V5.2.6), SCALANCE X208PRO (All versions \u003c V5.2.6), SCALANCE X212-2 (All versions \u003c V5.2.6), SCALANCE X212-2LD (All versions \u003c V5.2.6), SCALANCE X216 (All versions \u003c V5.2.6), SCALANCE X224 (All versions \u003c V5.2.6), SCALANCE XF201-3P IRT (All versions \u003c V5.5.2), SCALANCE XF202-2P IRT (All versions \u003c V5.5.2), SCALANCE XF204 (All versions \u003c V5.2.6), SCALANCE XF204-2 (All versions \u003c V5.2.6), SCALANCE XF204-2BA IRT (All versions \u003c V5.5.2), SCALANCE XF204IRT (All versions \u003c V5.5.2), SCALANCE XF206-1 (All versions \u003c V5.2.6), SCALANCE XF208 (All versions \u003c V5.2.6). Affected devices do not properly validate the URI of incoming HTTP GET requests. This could allow an unauthenticated remote attacker to crash affected devices." } ], "metrics": [ { "cvssV3_1": { "baseScore": 9.6, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-11T09:02:21.918Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-310038.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-26649", "datePublished": "2022-07-12T10:06:35", "dateReserved": "2022-03-07T00:00:00", "dateUpdated": "2024-08-03T05:11:43.372Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-26648
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SCALANCE X200-4P IRT |
Version: All versions < V5.5.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T05:11:43.481Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-310038.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SCALANCE X200-4P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2FM", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2LD TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X206-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X206-1LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X208PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X212-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X212-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X224", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF206-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.6" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT PRO (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT PRO (All versions \u003c V5.5.2), SCALANCE X204-2 (All versions \u003c V5.2.6), SCALANCE X204-2FM (All versions \u003c V5.2.6), SCALANCE X204-2LD (All versions \u003c V5.2.6), SCALANCE X204-2LD TS (All versions \u003c V5.2.6), SCALANCE X204-2TS (All versions \u003c V5.2.6), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT PRO (All versions \u003c V5.5.2), SCALANCE X206-1 (All versions \u003c V5.2.6), SCALANCE X206-1LD (All versions \u003c V5.2.6), SCALANCE X208 (All versions \u003c V5.2.6), SCALANCE X208PRO (All versions \u003c V5.2.6), SCALANCE X212-2 (All versions \u003c V5.2.6), SCALANCE X212-2LD (All versions \u003c V5.2.6), SCALANCE X216 (All versions \u003c V5.2.6), SCALANCE X224 (All versions \u003c V5.2.6), SCALANCE XF201-3P IRT (All versions \u003c V5.5.2), SCALANCE XF202-2P IRT (All versions \u003c V5.5.2), SCALANCE XF204 (All versions \u003c V5.2.6), SCALANCE XF204-2 (All versions \u003c V5.2.6), SCALANCE XF204-2BA IRT (All versions \u003c V5.5.2), SCALANCE XF204IRT (All versions \u003c V5.5.2), SCALANCE XF206-1 (All versions \u003c V5.2.6), SCALANCE XF208 (All versions \u003c V5.2.6). Affected devices do not properly validate the GET parameter XNo of incoming HTTP requests. This could allow an unauthenticated remote attacker to crash affected devices." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-11T09:02:20.560Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-310038.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-26648", "datePublished": "2022-07-12T10:06:34", "dateReserved": "2022-03-07T00:00:00", "dateUpdated": "2024-08-03T05:11:43.481Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-13946
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller |
Version: 0 < * |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2019-13946", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-07-09T18:06:01.358486Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-09T18:06:09.778Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-05T00:05:44.023Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-780073.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-780073.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V4.5" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V4.6" } ] }, { "defaultStatus": "unknown", "product": "PROFINET Driver for Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M804PB", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M826-2 SHDSL-Router", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3 (ROK)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (EU)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (NAM)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615 LAN-Router", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W-700 IEEE 802.11n family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c= V6.0.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X200-4P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2FM", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2LD TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X206-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X206-1LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X208PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X212-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X212-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X224", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (230V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (24V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 230V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 24V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X304-2FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X306-1LD FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (230V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (24V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 230V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 24V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH+", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH+", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X320-1 FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X320-1-2LD FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X408-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB-200 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC-200", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF-200BA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.3" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF206-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM-400 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V6.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP-200", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR-300WG family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR-500 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V6.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M TS (24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M TS (24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (230V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1616 and CP 1604", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V2.8" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 ERPC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 Lean", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1", "vendor": "Siemens", "versions": [ { "lessThan": "V3.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1", "vendor": "Siemens", "versions": [ { "lessThan": "V3.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 Advanced", "vendor": "Siemens", "versions": [ { "lessThan": "V3.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 OPC UA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200AL IM 157-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200M IM 153-4 PN IO HF (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200M IM 153-4 PN IO ST (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-3 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-4 PN HF", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN: IO-Link Master", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200S (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC IPC Support, Package for VxWorks", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-B", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-B Body", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-P", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-P Body", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV440 HR", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV440 SR", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV440 UR", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF180C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF182C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF600R family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION P", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V1.3" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET CP 343-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET CP 343-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET CP 343-1 Lean", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET CP 443-1", "vendor": "Siemens", "versions": [ { "lessThan": "V3.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET CP 443-1 Advanced", "vendor": "Siemens", "versions": [ { "lessThan": "V3.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SOFTNET-IE PNIO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit\ninternal resource allocation when multiple legitimate diagnostic package\nrequests are sent to the DCE-RPC interface.\nThis could lead to a denial of service condition due to lack of memory\nfor devices that include a vulnerable version of the stack.\n\nThe security vulnerability could be exploited by an attacker with network\naccess to an affected device. Successful exploitation requires no system\nprivileges and no user interaction. An attacker could use the vulnerability\nto compromise the availability of the device." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-07-09T12:03:58.088Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-780073.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-780073.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-13946", "datePublished": "2020-02-11T15:36:10", "dateReserved": "2019-07-18T00:00:00", "dateUpdated": "2024-08-05T00:05:44.023Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-28400
Vulnerability from cvelistv5
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller |
Version: All versions |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_b:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m812-1_adsl-router_annex_b", "vendor": "seimens", "versions": [ { "status": "affected", "version": "0" } ] }, { "cpes": [ "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_dk_standard_ethernet_controller:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "development_evaluation_kits_for_profinet_io_dk_standard_ethernet_controller", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_ek_ertec_200:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "development_evaluation_kits_for_profinet_io_ek_ertec_200", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_ek_ertec_200p:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "development_evaluation_kits_for_profinet_io_ek_ertec_200p", "vendor": "siemens", "versions": [ { "lessThan": "v4.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:ruggedcom_rm1224:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ruggedcom_rm1224", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:scalance_m804pb:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m804pb", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_a:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m812-1_adsl-router_annex_a", "vendor": "seimens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_b:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m812-1_adsl-router_annex_b", "vendor": "seimens", "versions": [ { "lessThan": "6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m816_1_adsl_router_annex_a:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m816_1_adsl_router_annex_a", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m816-1_adsl-router_annex_b:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m816-1_adsl-router_annex_b", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m826-2_shdsl-router:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m826-2_shdsl-router", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_m874_2:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_m874_2", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_m874_3:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_m874_3", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m876_3_evdo:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m876_3_evdo", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m876_3_rok:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m876_3_rok", "vendor": "siemens", "versions": [ { "lessThan": "6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m876_4_eu:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m876_4_eu", "vendor": "siemens", "versions": [ { "lessThan": "6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m876_4_nam:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m876_4_nam", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_s615", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w700_ieee_802.11n_family:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w700_ieee_802.11n_family", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1748_1_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1748_1_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1788_1_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1788_1_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1788_2_eec_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1788_2_eec_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1788_2_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1788_2_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1788_2ia_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1788_2ia_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_x200_4p_irt:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_x200_4p_irt", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_x201_3p_irt:0.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_x201_3p_irt", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_x201_3p_irt_pro:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_x201_3p_irt_pro", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalancce_x202_2p_irt:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalancce_x202_2p_irt", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_202_2p_irt_pro:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_202_2p_irt_pro", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalancce_x204_2:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalancce_x204_2", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_x204_2fm:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_x204_2fm", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_x204_2ld:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_x204_2ld", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_x204_2ld_ts:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_x204_2ld_ts", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_x204_2ts:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_x204_2ts", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2020-28400", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-06-13T18:59:11.953107Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-24T18:07:44.485Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-04T16:33:59.218Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7" } ] }, { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) EU", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) NAM", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M804PB", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M826-2 SHDSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-2", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-3", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-3 3G-Router (CN)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3 (ROK)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (NAM)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM853-1 (A1)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM853-1 (B1)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM853-1 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (A1)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (B1)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (CN)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (RoW)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615 EEC LAN-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615 LAN-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2 EEC M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2IA M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W721-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W721-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45 (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W738-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W738-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W761-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W761-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45 (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12 EEC (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2IA RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2IA RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X200-4P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2FM", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2LD", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2LD TS", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2TS", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X206-1", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X206-1LD", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X208", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X208PRO", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X212-2", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X212-2LD", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X216", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X224", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (230V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (24V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 230V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 24V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X304-2FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X306-1LD FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (230V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (24V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 230V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 24V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3LD", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3LD", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LD", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LD", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH+", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH+", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M TS", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M TS", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X320-1 FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X320-1-2LD FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X408-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3LD (SC, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3LD (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB208 (E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB208 (PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (SC, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (ST, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3LD (SC, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3LD (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB216 (E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB216 (PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2 (SC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2 (ST/BFOC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE EEC (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G (EIP DEF.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G (EIP def.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-3G PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-3G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204 DNA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA DNA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF206-1", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF208", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-8C", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-8C (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM416-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM416-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208 (Ethernet/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208PoE EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216 (Ethernet/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216POE EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M TS (24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M TS (24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (230V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324WG (24 x FE, AC 230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324WG (24 X FE, DC 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR326-2C PoE WG", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR326-2C PoE WG (without UL)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 1x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 24V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 2x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 1x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 24V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 2x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (2HR2)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CFU DIQ", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CFU PA", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CM 1542-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1604", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003e= V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1616", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003e= V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1626", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC IE/PB-LINK", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV540 H", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV540 S", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV550 H", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV550 S", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV560 U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV560 X", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET DK-16xx PN IO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003e= V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Power Line Booster PLB, Base Module", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PROFINET Driver", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V4.5" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC206-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC208", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SOFTNET-IE PNIO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-770", "description": "CWE-770: Allocation of Resources Without Limits or Throttling", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-10T13:53:22.763Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-28400", "datePublished": "2021-07-13T11:02:49", "dateReserved": "2020-11-10T00:00:00", "dateUpdated": "2024-12-10T13:53:22.763Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }