All the vulnerabilites related to Siemens - SCALANCE X-200 switch family (incl. SIPLUS NET variants)
cve-2020-15799
Vulnerability from cvelistv5
Published
2021-01-12 20:18
Modified
2024-08-04 13:30
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The vulnerability could allow an unauthenticated attacker to reboot the device over the network by using special urls from integrated web server of the affected products.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | Siemens | SCALANCE X-200 switch family (incl. SIPLUS NET variants) |
Version: All versions < V5.2.5 |
||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T13:30:21.812Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0). The vulnerability could allow an unauthenticated attacker to reboot the device over the network by using special urls from integrated web server of the affected products." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306: Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-09-14T10:47:08", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-15799", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V5.5.0" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0). The vulnerability could allow an unauthenticated attacker to reboot the device over the network by using special urls from integrated web server of the affected products." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-306: Missing Authentication for Critical Function" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-15799", "datePublished": "2021-01-12T20:18:33", "dateReserved": "2020-07-15T00:00:00", "dateUpdated": "2024-08-04T13:30:21.812Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-4848
Vulnerability from cvelistv5
Published
2018-06-14 00:00
Modified
2024-08-05 05:18
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.
References
Impacted products
Vendor | Product | Version | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SCALANCE X-200 switch family (incl. SIPLUS NET variants) |
Version: All versions < V5.2.3 |
||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T05:18:26.424Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "104494", "tags": [ "vdb-entry", "x_transferred" ], "url": "http://www.securityfocus.com/bid/104494" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480829.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.3" } ] }, { "product": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.4.1" } ] }, { "product": "SCALANCE X-200RNA switch family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.7" } ] }, { "product": "SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] } ], "datePublic": "2018-06-12T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.4.1), SCALANCE X-200RNA switch family (All versions \u003c V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c V4.1.3). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-80", "description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-13T00:00:00", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "104494", "tags": [ "vdb-entry" ], "url": "http://www.securityfocus.com/bid/104494" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480829.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2018-4848", "datePublished": "2018-06-14T00:00:00", "dateReserved": "2018-01-02T00:00:00", "dateUpdated": "2024-08-05T05:18:26.424Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-25226
Vulnerability from cvelistv5
Published
2021-01-12 20:18
Modified
2024-08-04 15:33
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The web server of the affected devices contains a vulnerability that may lead to a buffer overflow condition. An attacker could cause this condition on the webserver by sending a specially crafted request. The webserver could stop and not recover anymore.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | Siemens | SCALANCE X-200 switch family (incl. SIPLUS NET variants) |
Version: All versions < V5.2.5 |
||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T15:33:04.885Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0). The web server of the affected devices contains a vulnerability that may lead to a buffer overflow condition. An attacker could cause this condition on the webserver by sending a specially crafted request. The webserver could stop and not recover anymore." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-122", "description": "CWE-122: Heap-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-09-14T10:47:10", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-25226", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V5.5.0" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0). The web server of the affected devices contains a vulnerability that may lead to a buffer overflow condition. An attacker could cause this condition on the webserver by sending a specially crafted request. The webserver could stop and not recover anymore." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-122: Heap-based Buffer Overflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-25226", "datePublished": "2021-01-12T20:18:33", "dateReserved": "2020-09-10T00:00:00", "dateUpdated": "2024-08-04T15:33:04.885Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-10942
Vulnerability from cvelistv5
Published
2019-08-13 18:55
Modified
2024-08-04 22:40
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X204RNA (HSR) (All versions), SCALANCE X204RNA (PRP) (All versions), SCALANCE X204RNA EEC (HSR) (All versions), SCALANCE X204RNA EEC (PRP) (All versions), SCALANCE X204RNA EEC (PRP/HSR) (All versions). The device contains a vulnerability that could allow an attacker to trigger a denial-of-service condition by sending large message packages repeatedly to the telnet service. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-100232.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SCALANCE X-200 switch family (incl. SIPLUS NET variants) |
Version: All versions < V5.2.5 |
||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T22:40:15.308Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-100232.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X204RNA (HSR)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SCALANCE X204RNA (PRP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SCALANCE X204RNA EEC (HSR)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SCALANCE X204RNA EEC (PRP)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SCALANCE X204RNA EEC (PRP/HSR)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X204RNA (HSR) (All versions), SCALANCE X204RNA (PRP) (All versions), SCALANCE X204RNA EEC (HSR) (All versions), SCALANCE X204RNA EEC (PRP) (All versions), SCALANCE X204RNA EEC (PRP/HSR) (All versions). The device contains a vulnerability that could allow an attacker to trigger a denial-of-service condition by sending large message packages repeatedly to the telnet service. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-02-09T15:16:32", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-100232.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-10942", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V5.5.0" } ] } }, { "product_name": "SCALANCE X204RNA (HSR)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SCALANCE X204RNA (PRP)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SCALANCE X204RNA EEC (HSR)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SCALANCE X204RNA EEC (PRP)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SCALANCE X204RNA EEC (PRP/HSR)", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X204RNA (HSR) (All versions), SCALANCE X204RNA (PRP) (All versions), SCALANCE X204RNA EEC (HSR) (All versions), SCALANCE X204RNA EEC (PRP) (All versions), SCALANCE X204RNA EEC (PRP/HSR) (All versions). The device contains a vulnerability that could allow an attacker to trigger a denial-of-service condition by sending large message packages repeatedly to the telnet service. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-400: Uncontrolled Resource Consumption" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-100232.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-100232.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-10942", "datePublished": "2019-08-13T18:55:57", "dateReserved": "2019-04-08T00:00:00", "dateUpdated": "2024-08-04T22:40:15.308Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-15800
Vulnerability from cvelistv5
Published
2021-01-12 20:18
Modified
2024-08-04 13:30
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.0). The webserver of the affected devices contains a vulnerability that may lead to a heap overflow condition. An attacker could cause this condition on the webserver by sending specially crafted requests. This could stop the webserver temporarily.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SCALANCE X-200 switch family (incl. SIPLUS NET variants) |
Version: All versions < V5.2.5 |
||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T13:30:21.877Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.0" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c V4.1.0). The webserver of the affected devices contains a vulnerability that may lead to a heap overflow condition. An attacker could cause this condition on the webserver by sending specially crafted requests. This could stop the webserver temporarily." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-122", "description": "CWE-122: Heap-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-09-14T10:47:09", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-15800", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V5.5.0" } ] } }, { "product_name": "SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.0" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c V4.1.0). The webserver of the affected devices contains a vulnerability that may lead to a heap overflow condition. An attacker could cause this condition on the webserver by sending specially crafted requests. This could stop the webserver temporarily." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-122: Heap-based Buffer Overflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-15800", "datePublished": "2021-01-12T20:18:33", "dateReserved": "2020-07-15T00:00:00", "dateUpdated": "2024-08-04T13:30:21.877Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-13924
Vulnerability from cvelistv5
Published
2020-02-11 00:00
Modified
2024-08-05 00:05
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SCALANCE S602 |
Version: All versions < V4.1 |
||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T00:05:43.919Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-951513.pdf" }, { "tags": [ "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-07" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SCALANCE S602", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE S612", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE S623", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE S627-2M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 5.2.4" } ] }, { "product": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X-200RNA switch family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.7" } ] }, { "product": "SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 4.1.3" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003c V4.1), SCALANCE S612 (All versions \u003c V4.1), SCALANCE S623 (All versions \u003c V4.1), SCALANCE S627-2M (All versions \u003c V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-200RNA switch family (All versions \u003c V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-693", "description": "CWE-693: Protection Mechanism Failure", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-13T00:00:00", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-951513.pdf" }, { "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-07" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-13924", "datePublished": "2020-02-11T00:00:00", "dateReserved": "2019-07-18T00:00:00", "dateUpdated": "2024-08-05T00:05:43.919Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-4833
Vulnerability from cvelistv5
Published
2018-06-14 16:00
Modified
2024-08-05 05:18
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in RFID 181EIP (All versions), RUGGEDCOM Win (V4.4, V4.5, V5.0, and V5.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.6), SCALANCE X-300 switch family (incl. SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X408 (All versions < V4.1.3), SCALANCE X414 (All versions), SIMATIC RF182C (All versions). Unprivileged remote attackers located in the same local network segment (OSI Layer 2) could gain remote code execution on the affected products by sending a specially crafted DHCP response to a client's DHCP request.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-181018.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | RFID 181EIP |
Version: All versions |
||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T05:18:26.432Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-181018.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "RFID 181EIP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "RUGGEDCOM Win", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "V4.4, V4.5, V5.0, and V5.1" } ] }, { "product": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.3" } ] }, { "product": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.4.1" } ] }, { "product": "SCALANCE X-200RNA switch family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.6" } ] }, { "product": "SCALANCE X-300 switch family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X408", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X414", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC RF182C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "datePublic": "2018-06-12T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in RFID 181EIP (All versions), RUGGEDCOM Win (V4.4, V4.5, V5.0, and V5.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.4.1), SCALANCE X-200RNA switch family (All versions \u003c V3.2.6), SCALANCE X-300 switch family (incl. SIPLUS NET variants) (All versions \u003c V4.1.3), SCALANCE X408 (All versions \u003c V4.1.3), SCALANCE X414 (All versions), SIMATIC RF182C (All versions). Unprivileged remote attackers located in the same local network segment (OSI Layer 2) could gain remote code execution on the affected products by sending a specially crafted DHCP response to a client\u0027s DHCP request." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-122", "description": "CWE-122: Heap-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-12-14T21:05:17", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-181018.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2018-4833", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "RFID 181EIP", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "RUGGEDCOM Win", "version": { "version_data": [ { "version_value": "V4.4, V4.5, V5.0, and V5.1" } ] } }, { "product_name": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V5.2.3" } ] } }, { "product_name": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V5.4.1" } ] } }, { "product_name": "SCALANCE X-200RNA switch family", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2.6" } ] } }, { "product_name": "SCALANCE X-300 switch family (incl. SIPLUS NET variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X408", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X414", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC RF182C", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in RFID 181EIP (All versions), RUGGEDCOM Win (V4.4, V4.5, V5.0, and V5.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.4.1), SCALANCE X-200RNA switch family (All versions \u003c V3.2.6), SCALANCE X-300 switch family (incl. SIPLUS NET variants) (All versions \u003c V4.1.3), SCALANCE X408 (All versions \u003c V4.1.3), SCALANCE X414 (All versions), SIMATIC RF182C (All versions). Unprivileged remote attackers located in the same local network segment (OSI Layer 2) could gain remote code execution on the affected products by sending a specially crafted DHCP response to a client\u0027s DHCP request." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-122: Heap-based Buffer Overflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-181018.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-181018.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2018-4833", "datePublished": "2018-06-14T16:00:00", "dateReserved": "2018-01-02T00:00:00", "dateUpdated": "2024-08-05T05:18:26.432Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-6567
Vulnerability from cvelistv5
Published
2019-06-12 13:47
Modified
2024-08-04 20:23
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All Versions < V5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. An attacker may extract and recover device passwords from the device configuration. Successful exploitation requires access to a device configuration backup and impacts confidentiality of the stored passwords.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-646841.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SCALANCE X-200 switch family (incl. SIPLUS NET variants) |
Version: All Versions < V5.2.4 |
||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:23:22.108Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-646841.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.2.4" } ] }, { "product": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X-414-3E", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All Versions \u003c V5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c V4.1.3), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. An attacker may extract and recover device passwords from the device configuration. Successful exploitation requires access to a device configuration backup and impacts confidentiality of the stored passwords." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-257", "description": "CWE-257: Storing Passwords in a Recoverable Format", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-02-09T15:38:17", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-646841.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-6567", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)", "version": { "version_data": [ { "version_value": "All Versions \u003c V5.2.4" } ] } }, { "product_name": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V5.5.0" } ] } }, { "product_name": "SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X-414-3E", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All Versions \u003c V5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c V4.1.3), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. An attacker may extract and recover device passwords from the device configuration. Successful exploitation requires access to a device configuration backup and impacts confidentiality of the stored passwords." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-257: Storing Passwords in a Recoverable Format" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-646841.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-646841.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-6567", "datePublished": "2019-06-12T13:47:56", "dateReserved": "2019-01-22T00:00:00", "dateUpdated": "2024-08-04T20:23:22.108Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-28391
Vulnerability from cvelistv5
Published
2021-01-12 00:00
Modified
2024-08-04 16:33
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7). Devices create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic.
References
Impacted products
Vendor | Product | Version | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SCALANCE X-200 switch family (incl. SIPLUS NET variants) |
Version: All versions < V5.2.5 |
||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T16:33:59.106Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-274900.pdf" }, { "tags": [ "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X-200RNA switch family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.7" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-200RNA switch family (All versions \u003c V3.2.7). Devices create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-321", "description": "CWE-321: Use of Hard-coded Cryptographic Key", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-13T00:00:00", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-274900.pdf" }, { "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-02" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-28391", "datePublished": "2021-01-12T00:00:00", "dateReserved": "2020-11-10T00:00:00", "dateUpdated": "2024-08-04T16:33:59.106Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }