    CVE-2018-10611 (GCVE-0-2018-10611)

    Vulnerability from cvelistv5 – Published: 2018-06-04 14:00 – Updated: 2024-09-16 18:33
    VLAI
    Summary
    Java remote method invocation (RMI) input port in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior may be exploited to allow unauthenticated users to launch applications and support remote code execution through web services.
    Severity
    No CVSS data available.
    CWE
    • CWE-287 - Improper Authentication CWE-287
    Assigner
    References
    Impacted products
    Vendor Product Version
    GE MDS PulseNET and MDS PulseNET Enterprise Affected: Version 3.2.1 and prior
    Create a notification for this product.
    Date Public
    2018-05-31 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T07:46:46.151Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "104377",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/104377"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "MDS PulseNET and MDS PulseNET Enterprise",
              "vendor": "GE",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version 3.2.1 and prior"
                }
              ]
            }
          ],
          "datePublic": "2018-05-31T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Java remote method invocation (RMI) input port in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior may be exploited to allow unauthenticated users to launch applications and support remote code execution through web services."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "Improper Authentication CWE-287",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-06-05T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "104377",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/104377"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-05-31T00:00:00",
              "ID": "CVE-2018-10611",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "MDS PulseNET and MDS PulseNET Enterprise",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Version 3.2.1 and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "GE"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Java remote method invocation (RMI) input port in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior may be exploited to allow unauthenticated users to launch applications and support remote code execution through web services."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Improper Authentication CWE-287"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "104377",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/104377"
                },
                {
                  "name": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1",
                  "refsource": "CONFIRM",
                  "url": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-10611",
        "datePublished": "2018-06-04T14:00:00.000Z",
        "dateReserved": "2018-05-01T00:00:00.000Z",
        "dateUpdated": "2024-09-16T18:33:38.782Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-10615 (GCVE-0-2018-10615)

    Vulnerability from cvelistv5 – Published: 2018-06-04 14:00 – Updated: 2024-09-16 23:51
    VLAI
    Summary
    Directory traversal may lead to files being exfiltrated or deleted on the GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior host platform.
    Severity
    No CVSS data available.
    CWE
    • CWE-23 - Relative path traversal CWE-23
    Assigner
    References
    Impacted products
    Vendor Product Version
    GE MDS PulseNET and MDS PulseNET Enterprise Affected: Version 3.2.1 and prior
    Create a notification for this product.
    Date Public
    2018-05-31 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T07:46:46.021Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "104377",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/104377"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "MDS PulseNET and MDS PulseNET Enterprise",
              "vendor": "GE",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version 3.2.1 and prior"
                }
              ]
            }
          ],
          "datePublic": "2018-05-31T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Directory traversal may lead to files being exfiltrated or deleted on the GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior host platform."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-23",
                  "description": "Relative path traversal CWE-23",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-06-05T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "104377",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/104377"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-05-31T00:00:00",
              "ID": "CVE-2018-10615",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "MDS PulseNET and MDS PulseNET Enterprise",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Version 3.2.1 and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "GE"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Directory traversal may lead to files being exfiltrated or deleted on the GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior host platform."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Relative path traversal CWE-23"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "104377",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/104377"
                },
                {
                  "name": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1",
                  "refsource": "CONFIRM",
                  "url": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-10615",
        "datePublished": "2018-06-04T14:00:00.000Z",
        "dateReserved": "2018-05-01T00:00:00.000Z",
        "dateUpdated": "2024-09-16T23:51:13.413Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-10613 (GCVE-0-2018-10613)

    Vulnerability from cvelistv5 – Published: 2018-06-04 14:00 – Updated: 2024-09-16 16:52
    VLAI
    Summary
    Multiple variants of XML External Entity (XXE) attacks may be used to exfiltrate data from the host Windows platform in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    GE MDS PulseNET and MDS PulseNET Enterprise Affected: Version 3.2.1 and prior
    Create a notification for this product.
    Date Public
    2018-05-31 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T07:46:46.243Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "104377",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/104377"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "MDS PulseNET and MDS PulseNET Enterprise",
              "vendor": "GE",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version 3.2.1 and prior"
                }
              ]
            }
          ],
          "datePublic": "2018-05-31T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Multiple variants of XML External Entity (XXE) attacks may be used to exfiltrate data from the host Windows platform in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-611",
                  "description": "XXE CWE-611",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-06-05T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "104377",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/104377"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-05-31T00:00:00",
              "ID": "CVE-2018-10613",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "MDS PulseNET and MDS PulseNET Enterprise",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Version 3.2.1 and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "GE"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Multiple variants of XML External Entity (XXE) attacks may be used to exfiltrate data from the host Windows platform in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "XXE CWE-611"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "104377",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/104377"
                },
                {
                  "name": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1",
                  "refsource": "CONFIRM",
                  "url": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-10613",
        "datePublished": "2018-06-04T14:00:00.000Z",
        "dateReserved": "2018-05-01T00:00:00.000Z",
        "dateUpdated": "2024-09-16T16:52:57.226Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-10611 (GCVE-0-2018-10611)

    Vulnerability from nvd – Published: 2018-06-04 14:00 – Updated: 2024-09-16 18:33
    VLAI
    Summary
    Java remote method invocation (RMI) input port in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior may be exploited to allow unauthenticated users to launch applications and support remote code execution through web services.
    Severity
    No CVSS data available.
    CWE
    • CWE-287 - Improper Authentication CWE-287
    Assigner
    References
    Impacted products
    Vendor Product Version
    GE MDS PulseNET and MDS PulseNET Enterprise Affected: Version 3.2.1 and prior
    Create a notification for this product.
    Date Public
    2018-05-31 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T07:46:46.151Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "104377",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/104377"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "MDS PulseNET and MDS PulseNET Enterprise",
              "vendor": "GE",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version 3.2.1 and prior"
                }
              ]
            }
          ],
          "datePublic": "2018-05-31T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Java remote method invocation (RMI) input port in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior may be exploited to allow unauthenticated users to launch applications and support remote code execution through web services."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "Improper Authentication CWE-287",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-06-05T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "104377",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/104377"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-05-31T00:00:00",
              "ID": "CVE-2018-10611",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "MDS PulseNET and MDS PulseNET Enterprise",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Version 3.2.1 and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "GE"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Java remote method invocation (RMI) input port in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior may be exploited to allow unauthenticated users to launch applications and support remote code execution through web services."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Improper Authentication CWE-287"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "104377",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/104377"
                },
                {
                  "name": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1",
                  "refsource": "CONFIRM",
                  "url": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-10611",
        "datePublished": "2018-06-04T14:00:00.000Z",
        "dateReserved": "2018-05-01T00:00:00.000Z",
        "dateUpdated": "2024-09-16T18:33:38.782Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-10615 (GCVE-0-2018-10615)

    Vulnerability from nvd – Published: 2018-06-04 14:00 – Updated: 2024-09-16 23:51
    VLAI
    Summary
    Directory traversal may lead to files being exfiltrated or deleted on the GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior host platform.
    Severity
    No CVSS data available.
    CWE
    • CWE-23 - Relative path traversal CWE-23
    Assigner
    References
    Impacted products
    Vendor Product Version
    GE MDS PulseNET and MDS PulseNET Enterprise Affected: Version 3.2.1 and prior
    Create a notification for this product.
    Date Public
    2018-05-31 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T07:46:46.021Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "104377",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/104377"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "MDS PulseNET and MDS PulseNET Enterprise",
              "vendor": "GE",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version 3.2.1 and prior"
                }
              ]
            }
          ],
          "datePublic": "2018-05-31T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Directory traversal may lead to files being exfiltrated or deleted on the GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior host platform."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-23",
                  "description": "Relative path traversal CWE-23",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-06-05T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "104377",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/104377"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-05-31T00:00:00",
              "ID": "CVE-2018-10615",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "MDS PulseNET and MDS PulseNET Enterprise",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Version 3.2.1 and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "GE"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Directory traversal may lead to files being exfiltrated or deleted on the GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior host platform."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Relative path traversal CWE-23"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "104377",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/104377"
                },
                {
                  "name": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1",
                  "refsource": "CONFIRM",
                  "url": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-10615",
        "datePublished": "2018-06-04T14:00:00.000Z",
        "dateReserved": "2018-05-01T00:00:00.000Z",
        "dateUpdated": "2024-09-16T23:51:13.413Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-10613 (GCVE-0-2018-10613)

    Vulnerability from nvd – Published: 2018-06-04 14:00 – Updated: 2024-09-16 16:52
    VLAI
    Summary
    Multiple variants of XML External Entity (XXE) attacks may be used to exfiltrate data from the host Windows platform in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    GE MDS PulseNET and MDS PulseNET Enterprise Affected: Version 3.2.1 and prior
    Create a notification for this product.
    Date Public
    2018-05-31 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T07:46:46.243Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "104377",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/104377"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "MDS PulseNET and MDS PulseNET Enterprise",
              "vendor": "GE",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version 3.2.1 and prior"
                }
              ]
            }
          ],
          "datePublic": "2018-05-31T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Multiple variants of XML External Entity (XXE) attacks may be used to exfiltrate data from the host Windows platform in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-611",
                  "description": "XXE CWE-611",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-06-05T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "104377",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/104377"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-05-31T00:00:00",
              "ID": "CVE-2018-10613",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "MDS PulseNET and MDS PulseNET Enterprise",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Version 3.2.1 and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "GE"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Multiple variants of XML External Entity (XXE) attacks may be used to exfiltrate data from the host Windows platform in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "XXE CWE-611"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "104377",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/104377"
                },
                {
                  "name": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1",
                  "refsource": "CONFIRM",
                  "url": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-10613",
        "datePublished": "2018-06-04T14:00:00.000Z",
        "dateReserved": "2018-05-01T00:00:00.000Z",
        "dateUpdated": "2024-09-16T16:52:57.226Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }