All the vulnerabilites related to CODESYS - CODESYS Remote Target Visu Toolkit
cve-2022-30791
Vulnerability from cvelistv5
Published
2022-07-11 10:40
Modified
2024-09-16 16:48
Summary
CODESYS V3: CmpBlkDrvTcp allows unauthenticated attackers to block all its available TCP connections
Impacted products
Vendor Product Version
CODESYS CODESYS Control RTE (for Beckhoff CX) SL Version: V3   < V3.5.18.20
CODESYS CODESYS Control Win (SL) Version: V3   < V3.5.18.20
CODESYS CODESYS Gateway Version: V3   < V3.5.18.20
CODESYS CODESYS Edge Gateway for Windows Version: V3   < V3.5.18.20
CODESYS CODESYS HMI (SL) Version: V3   < V3.5.18.20
CODESYS CODESYS Development System V3 Version: V3   < V3.5.18.10
CODESYS CODESYS Control Runtime System Toolkit Version: V3   < V3.5.18.20
CODESYS CODESYS Embedded Target Visu Toolkit Version: V3   < V3.5.18.20
CODESYS CODESYS Remote Target Visu Toolkit Version: V3   < V3.5.18.20
CODESYS CODESYS Control for BeagleBone SL Version: V3   < V4.5.0.0
CODESYS CODESYS Control for Beckhoff CX9020 SL Version: V3   < V4.5.0.0
CODESYS CODESYS Control for emPC-A/iMX6 SL Version: V3   < V4.5.0.0
CODESYS CODESYS Control for IOT2000 SL Version: V3   < V4.5.0.0
CODESYS CODESYS Control for Linux SL Version: V3   < V4.5.0.0
CODESYS CODESYS Control for PFC100 SL Version: V3   < V4.5.0.0
CODESYS CODESYS Control for PFC200 SL Version: V3   < V4.5.0.0
CODESYS CODESYS Control for PLCnext SL Version: V3   < V4.5.0.0
CODESYS CODESYS Control for Raspberry Pi SL Version: V3   < V4.5.0.0
CODESYS CODESYS Control for WAGO Touch Panels 600 SL Version: V3   < V4.5.0.0
CODESYS CODESYS Edge Gateway for Linux Version: V3   < V4.5.0.0
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T07:03:38.611Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download="
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "CODESYS Control RTE (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control RTE (for Beckhoff CX) SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Win (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Gateway",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Edge Gateway for Windows",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS HMI (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Development System V3",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.10",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Runtime System Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Embedded Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Remote Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for BeagleBone SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Beckhoff CX9020 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for emPC-A/iMX6 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for IOT2000 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Linux SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC100 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC200 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PLCnext SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Raspberry Pi SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for WAGO Touch Panels 600 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Edge Gateway for Linux",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-07-08T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In CmpBlkDrvTcp of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new TCP connections. Existing connections are not affected."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400 Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-11T10:40:38",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download="
        }
      ],
      "source": {
        "defect": [
          "CERT@VDE#",
          "64129"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "CODESYS V3: CmpBlkDrvTcp allows unauthenticated attackers to block all its available TCP connections",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "DATE_PUBLIC": "2022-07-08T06:00:00.000Z",
          "ID": "CVE-2022-30791",
          "STATE": "PUBLIC",
          "TITLE": "CODESYS V3: CmpBlkDrvTcp allows unauthenticated attackers to block all its available TCP connections"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CODESYS Control RTE (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control RTE (for Beckhoff CX) SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Win (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Gateway",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Edge Gateway for Windows",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS HMI (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Development System V3",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.10"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Runtime System Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Embedded Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Remote Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for BeagleBone SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Beckhoff CX9020 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for emPC-A/iMX6 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for IOT2000 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Linux SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC100 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC200 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PLCnext SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Raspberry Pi SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for WAGO Touch Panels 600 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Edge Gateway for Linux",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "CODESYS"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In CmpBlkDrvTcp of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new TCP connections. Existing connections are not affected."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-400 Uncontrolled Resource Consumption"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download=",
              "refsource": "CONFIRM",
              "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download="
            }
          ]
        },
        "source": {
          "defect": [
            "CERT@VDE#",
            "64129"
          ],
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2022-30791",
    "datePublished": "2022-07-11T10:40:38.913416Z",
    "dateReserved": "2022-05-16T00:00:00",
    "dateUpdated": "2024-09-16T16:48:31.565Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-22513
Vulnerability from cvelistv5
Published
2022-04-07 18:21
Modified
2024-09-17 04:29
Summary
Null Pointer Dereference in multiple CODESYS products can lead to a DoS.
Impacted products
Vendor Product Version
CODESYS CODESYS Control RTE (for Beckhoff CX) SL Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Control Win (SL) Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Gateway Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Edge Gateway for Windows Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS HMI (SL) Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Development System V3 Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Control Runtime System Toolkit Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Embedded Target Visu Toolkit Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Remote Target Visu Toolkit Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Control for BeagleBone SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for Beckhoff CX9020 SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for emPC-A/iMX6 SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for IOT2000 SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for Linux SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for PFC100 SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for PFC200 SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for PLCnext SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for Raspberry Pi SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for WAGO Touch Panels 600 SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Edge Gateway for Linux Version: V4.5.0.0   < V4.5.0.0
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:14:55.460Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17093\u0026token=15cd8424832ea10dcd4873a409a09a539ee381ca\u0026download="
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "CODESYS Control RTE (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control RTE (for Beckhoff CX) SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Win (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Gateway",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Edge Gateway for Windows",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS HMI (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Development System V3",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Runtime System Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Embedded Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Remote Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for BeagleBone SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Beckhoff CX9020 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for emPC-A/iMX6 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for IOT2000 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Linux SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC100 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC200 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PLCnext SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Raspberry Pi SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for WAGO Touch Panels 600 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Edge Gateway for Linux",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-04-06T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An authenticated remote attacker can cause a null pointer dereference in the CmpSettings component of the affected CODESYS products which leads to a crash."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-476",
              "description": "CWE-476 NULL Pointer Dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-27T05:55:10",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17093\u0026token=15cd8424832ea10dcd4873a409a09a539ee381ca\u0026download="
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Null Pointer Dereference in multiple CODESYS products can lead to a DoS.",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "DATE_PUBLIC": "2022-04-06T10:00:00.000Z",
          "ID": "CVE-2022-22513",
          "STATE": "PUBLIC",
          "TITLE": "Null Pointer Dereference in multiple CODESYS products can lead to a DoS."
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CODESYS Control RTE (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control RTE (for Beckhoff CX) SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Win (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Gateway",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Edge Gateway for Windows",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS HMI (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Development System V3",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Runtime System Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Embedded Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Remote Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for BeagleBone SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Beckhoff CX9020 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for emPC-A/iMX6 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for IOT2000 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Linux SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC100 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC200 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PLCnext SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Raspberry Pi SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for WAGO Touch Panels 600 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Edge Gateway for Linux",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "CODESYS"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An authenticated remote attacker can cause a null pointer dereference in the CmpSettings component of the affected CODESYS products which leads to a crash."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-476 NULL Pointer Dereference"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17093\u0026token=15cd8424832ea10dcd4873a409a09a539ee381ca\u0026download=",
              "refsource": "MISC",
              "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17093\u0026token=15cd8424832ea10dcd4873a409a09a539ee381ca\u0026download="
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2022-22513",
    "datePublished": "2022-04-07T18:21:12.792321Z",
    "dateReserved": "2022-01-03T00:00:00",
    "dateUpdated": "2024-09-17T04:29:14.122Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-22519
Vulnerability from cvelistv5
Published
2022-04-07 18:21
Modified
2024-09-17 03:22
Summary
Special HTTP(s) Requests can cause a buffer-read causing a crash of the webserver and the runtime system.
Impacted products
Vendor Product Version
CODESYS CODESYS Control RTE (for Beckhoff CX) SL Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Control Win (SL) Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS HMI (SL) Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Control Runtime System Toolkit Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Embedded Target Visu Toolkit Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Remote Target Visu Toolkit Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Control for BeagleBone SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for Beckhoff CX9020 SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for emPC-A/iMX6 SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for IOT2000 SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for Linux SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for PFC100 SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for PFC200 SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for PLCnext SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for Raspberry Pi SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for WAGO Touch Panels 600 SL Version: V4.5.0.0   < V4.5.0.0
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:14:55.378Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17094\u0026token=2fb188e2213c74194e81ba61ff99f1c68602ba4d\u0026download="
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "CODESYS Control RTE (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control RTE (for Beckhoff CX) SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Win (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS HMI (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Runtime System Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Embedded Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Remote Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for BeagleBone SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Beckhoff CX9020 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for emPC-A/iMX6 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for IOT2000 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Linux SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC100 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC200 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PLCnext SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Raspberry Pi SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for WAGO Touch Panels 600 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-04-06T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote, unauthenticated attacker can send a specific crafted HTTP or HTTPS requests causing a buffer over-read resulting in a crash of the webserver of the CODESYS Control runtime system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-126",
              "description": "CWE-126 Buffer Over-read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-27T05:55:13",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17094\u0026token=2fb188e2213c74194e81ba61ff99f1c68602ba4d\u0026download="
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Special HTTP(s) Requests can cause a buffer-read causing a crash of the webserver and the runtime system.",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "DATE_PUBLIC": "2022-04-06T10:00:00.000Z",
          "ID": "CVE-2022-22519",
          "STATE": "PUBLIC",
          "TITLE": "Special HTTP(s) Requests can cause a buffer-read causing a crash of the webserver and the runtime system."
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CODESYS Control RTE (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control RTE (for Beckhoff CX) SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Win (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS HMI (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Runtime System Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Embedded Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Remote Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for BeagleBone SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Beckhoff CX9020 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for emPC-A/iMX6 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for IOT2000 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Linux SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC100 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC200 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PLCnext SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Raspberry Pi SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for WAGO Touch Panels 600 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "CODESYS"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote, unauthenticated attacker can send a specific crafted HTTP or HTTPS requests causing a buffer over-read resulting in a crash of the webserver of the CODESYS Control runtime system."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-126 Buffer Over-read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17094\u0026token=2fb188e2213c74194e81ba61ff99f1c68602ba4d\u0026download=",
              "refsource": "MISC",
              "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17094\u0026token=2fb188e2213c74194e81ba61ff99f1c68602ba4d\u0026download="
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2022-22519",
    "datePublished": "2022-04-07T18:21:23.764420Z",
    "dateReserved": "2022-01-03T00:00:00",
    "dateUpdated": "2024-09-17T03:22:45.345Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-22517
Vulnerability from cvelistv5
Published
2022-04-07 18:21
Modified
2024-09-16 22:16
Summary
Communication Components in multiple CODESYS products vulnerable to communication channel disruption
Impacted products
Vendor Product Version
CODESYS CODESYS Control RTE (for Beckhoff CX) SL Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Control Win (SL) Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Gateway Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Edge Gateway for Windows Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS HMI (SL) Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Development System V3 Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Control Runtime System Toolkit Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Embedded Target Visu Toolkit Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Remote Target Visu Toolkit Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Control for BeagleBone SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for Beckhoff CX9020 SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for emPC-A/iMX6 SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for IOT2000 SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for Linux SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for PFC100 SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for PFC200 SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for PLCnext SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for Raspberry Pi SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for WAGO Touch Panels 600 SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Edge Gateway for Linux Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS OPC DA Server SL Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS PLCHandler Version: V3.5.18.0   < V3.5.18.0
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:14:55.454Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17091\u0026token=c450f8bbbd838c647d102f359356386c6ea5aeca\u0026download="
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "CODESYS Control RTE (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control RTE (for Beckhoff CX) SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Win (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Gateway",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Edge Gateway for Windows",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS HMI (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Development System V3",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Runtime System Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Embedded Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Remote Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for BeagleBone SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Beckhoff CX9020 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for emPC-A/iMX6 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for IOT2000 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Linux SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC100 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC200 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PLCnext SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Raspberry Pi SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for WAGO Touch Panels 600 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Edge Gateway for Linux",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS OPC DA Server SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS PLCHandler",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-04-06T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An unauthenticated, remote attacker can disrupt existing communication channels between CODESYS products by guessing a valid channel ID and injecting packets. This results in the communication channel to be closed."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-334",
              "description": "CWE-334 Small Space of Random Values",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-07T18:21:19",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17091\u0026token=c450f8bbbd838c647d102f359356386c6ea5aeca\u0026download="
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Communication Components in multiple CODESYS products vulnerable to communication channel disruption",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "DATE_PUBLIC": "2022-04-06T10:00:00.000Z",
          "ID": "CVE-2022-22517",
          "STATE": "PUBLIC",
          "TITLE": "Communication Components in multiple CODESYS products vulnerable to communication channel disruption"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CODESYS Control RTE (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control RTE (for Beckhoff CX) SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Win (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Gateway",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Edge Gateway for Windows",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS HMI (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Development System V3",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Runtime System Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Embedded Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Remote Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for BeagleBone SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Beckhoff CX9020 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for emPC-A/iMX6 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for IOT2000 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Linux SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC100 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC200 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PLCnext SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Raspberry Pi SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for WAGO Touch Panels 600 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Edge Gateway for Linux",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS OPC DA Server SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS PLCHandler",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "CODESYS"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An unauthenticated, remote attacker can disrupt existing communication channels between CODESYS products by guessing a valid channel ID and injecting packets. This results in the communication channel to be closed."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-334 Small Space of Random Values"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17091\u0026token=c450f8bbbd838c647d102f359356386c6ea5aeca\u0026download=",
              "refsource": "MISC",
              "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17091\u0026token=c450f8bbbd838c647d102f359356386c6ea5aeca\u0026download="
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2022-22517",
    "datePublished": "2022-04-07T18:21:20.091353Z",
    "dateReserved": "2022-01-03T00:00:00",
    "dateUpdated": "2024-09-16T22:16:04.923Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-22514
Vulnerability from cvelistv5
Published
2022-04-07 18:21
Modified
2024-09-17 03:03
Summary
Untrusted Pointer Dereference in multiple CODESYS products can lead to a DoS.
Impacted products
Vendor Product Version
CODESYS CODESYS Control RTE (for Beckhoff CX) SL Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Control Win (SL) Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Gateway Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Edge Gateway for Windows Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS HMI (SL) Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Development System V3 Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Control Runtime System Toolkit Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Embedded Target Visu Toolkit Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Remote Target Visu Toolkit Version: V3.5.18.0   < V3.5.18.0
CODESYS CODESYS Control for BeagleBone SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for Beckhoff CX9020 SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for emPC-A/iMX6 SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for IOT2000 SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for Linux SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for PFC100 SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for PFC200 SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for PLCnext SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for Raspberry Pi SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Control for WAGO Touch Panels 600 SL Version: V4.5.0.0   < V4.5.0.0
CODESYS CODESYS Edge Gateway for Linux Version: V4.5.0.0   < V4.5.0.0
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:14:55.446Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17093\u0026token=15cd8424832ea10dcd4873a409a09a539ee381ca\u0026download="
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "CODESYS Control RTE (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control RTE (for Beckhoff CX) SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Win (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Gateway",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Edge Gateway for Windows",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS HMI (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Development System V3",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Runtime System Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Embedded Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Remote Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.0",
              "status": "affected",
              "version": "V3.5.18.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for BeagleBone SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Beckhoff CX9020 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for emPC-A/iMX6 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for IOT2000 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Linux SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC100 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC200 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PLCnext SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Raspberry Pi SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for WAGO Touch Panels 600 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Edge Gateway for Linux",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4.5.0.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-04-06T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An authenticated, remote attacker can gain access to a dereferenced pointer contained in a request. The accesses can subsequently lead to local overwriting of memory in the CmpTraceMgr, whereby the attacker can neither gain the values read internally nor control the values to be written. If invalid memory is accessed, this results in a crash."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-822",
              "description": "CWE-822: Untrusted Pointer Dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-27T05:55:11",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17093\u0026token=15cd8424832ea10dcd4873a409a09a539ee381ca\u0026download="
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Untrusted Pointer Dereference in multiple CODESYS products can lead to a DoS.",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "DATE_PUBLIC": "2022-04-06T10:00:00.000Z",
          "ID": "CVE-2022-22514",
          "STATE": "PUBLIC",
          "TITLE": "Untrusted Pointer Dereference in multiple CODESYS products can lead to a DoS."
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CODESYS Control RTE (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control RTE (for Beckhoff CX) SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Win (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Gateway",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Edge Gateway for Windows",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS HMI (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Development System V3",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Runtime System Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Embedded Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Remote Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3.5.18.0",
                            "version_value": "V3.5.18.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for BeagleBone SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Beckhoff CX9020 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for emPC-A/iMX6 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for IOT2000 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Linux SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC100 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC200 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PLCnext SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Raspberry Pi SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for WAGO Touch Panels 600 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Edge Gateway for Linux",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4.5.0.0",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "CODESYS"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An authenticated, remote attacker can gain access to a dereferenced pointer contained in a request. The accesses can subsequently lead to local overwriting of memory in the CmpTraceMgr, whereby the attacker can neither gain the values read internally nor control the values to be written. If invalid memory is accessed, this results in a crash."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-822: Untrusted Pointer Dereference"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17093\u0026token=15cd8424832ea10dcd4873a409a09a539ee381ca\u0026download=",
              "refsource": "MISC",
              "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17093\u0026token=15cd8424832ea10dcd4873a409a09a539ee381ca\u0026download="
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2022-22514",
    "datePublished": "2022-04-07T18:21:14.309072Z",
    "dateReserved": "2022-01-03T00:00:00",
    "dateUpdated": "2024-09-17T03:03:50.086Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-8175
Vulnerability from cvelistv5
Published
2024-09-25 08:04
Modified
2024-09-25 14:02
Summary
CODESYS: web server vulnerable to DoS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "runtime_toolkit",
            "vendor": "codesys",
            "versions": [
              {
                "lessThan": "4.14.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:codesys:control_rte_\\(for_beckhoff_cx\\)_sl:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "control_rte_\\(for_beckhoff_cx\\)_sl",
            "vendor": "codesys",
            "versions": [
              {
                "lessThan": "3.5.20.30",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:codesys:virtual_control_sl:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "virtual_control_sl",
            "vendor": "codesys",
            "versions": [
              {
                "lessThan": "4.14.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:hmi_sl:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "runtime_toolkit",
            "vendor": "codesys",
            "versions": [
              {
                "lessThan": "3.5.20.30",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-8175",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-25T13:44:03.391474Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-25T14:02:28.368Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for BeagleBone SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.14.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for emPC-A/iMX6 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.14.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for IOT2000 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.14.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for Linux ARM SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.14.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for Linux SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.14.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for PFC100 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.14.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for PFC200 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.14.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for PLCnext SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.14.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for Raspberry Pi SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.14.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control for WAGO Touch Panels 600 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.14.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control RTE (for Beckhoff CX) SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "3.5.20.30",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control RTE (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "3.5.20.30",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Control Win (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "3.5.20.30",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Embedded Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "3.5.20.30",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS HMI (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "3.5.20.30",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Remote Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "3.5.20.30",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Runtime Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "3.5.20.30",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CODESYS Virtual Control SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "4.14.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "ABB"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An unauthenticated remote attacker can\u0026nbsp;causes the CODESYS web server to access invalid memory which results in a DoS."
            }
          ],
          "value": "An unauthenticated remote attacker can\u00a0causes the CODESYS web server to access invalid memory which results in a DoS."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-754",
              "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-25T13:33:10.408Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2024-057"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18604\u0026token=d5e1e2820ee63077b875b3bb41014b1f102e88a3\u0026download="
        }
      ],
      "source": {
        "advisory": "VDE-2024-057",
        "defect": [
          "CERT@VDE#641681"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "CODESYS: web server vulnerable to DoS",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2024-8175",
    "datePublished": "2024-09-25T08:04:23.196Z",
    "dateReserved": "2024-08-26T09:58:34.794Z",
    "dateUpdated": "2024-09-25T14:02:28.368Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-22515
Vulnerability from cvelistv5
Published
2022-04-07 18:21
Modified
2024-09-16 17:59
Summary
A component of the CODESYS Control runtime system allows read and write access to configuration files
Impacted products
Vendor Product Version
CODESYS CODESYS Control RTE (for Beckhoff CX) SL Version: V3   < V3.5.17.40
CODESYS CODESYS Control Win (SL) Version: V3   < V3.5.17.40
CODESYS CODESYS HMI (SL) Version: V3   < V3.5.17.40
CODESYS CODESYS Development System V3 Version: V3   < V3.5.17.40
CODESYS CODESYS Control Runtime System Toolkit Version: V3   < V3.5.17.40
CODESYS CODESYS Embedded Target Visu Toolkit Version: V3   < V3.5.17.40
CODESYS CODESYS Remote Target Visu Toolkit Version: V3   < V3.5.17.40
CODESYS CODESYS Control for BeagleBone SL Version: V4   < V4.5.0.0
CODESYS CODESYS Control for Beckhoff CX9020 SL Version: V4   < V4.5.0.0
CODESYS CODESYS Control for emPC-A/iMX6 SL Version: V4   < V4.5.0.0
CODESYS CODESYS Control for IOT2000 SL Version: V4   < V4.5.0.0
CODESYS CODESYS Control for Linux SL Version: V4   < V4.5.0.0
CODESYS CODESYS Control for PFC100 SL Version: V4   < V4.5.0.0
CODESYS CODESYS Control for PFC200 SL Version: V4   < V4.5.0.0
CODESYS CODESYS Control for PLCnext SL Version: V4   < V4.5.0.0
CODESYS CODESYS Control for Raspberry Pi SL Version: V4   < V4.5.0.0
CODESYS CODESYS Control for WAGO Touch Panels 600 SL Version: V4   < V4.5.0.0
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:14:55.437Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17089\u0026token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53\u0026download="
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "CODESYS Control RTE (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.17.40",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control RTE (for Beckhoff CX) SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.17.40",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Win (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.17.40",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS HMI (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.17.40",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Development System V3",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.17.40",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Runtime System Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.17.40",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Embedded Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.17.40",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Remote Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.17.40",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for BeagleBone SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Beckhoff CX9020 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for emPC-A/iMX6 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for IOT2000 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Linux SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC100 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC200 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PLCnext SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Raspberry Pi SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for WAGO Touch Panels 600 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-06-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-668",
              "description": "CWE-668 Exposure of Resource to Wrong Sphere",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-12T07:45:29",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17089\u0026token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53\u0026download="
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "A component of the CODESYS Control runtime system allows read and write access to configuration files",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "DATE_PUBLIC": "2022-06-01T10:00:00.000Z",
          "ID": "CVE-2022-22515",
          "STATE": "PUBLIC",
          "TITLE": "A component of the CODESYS Control runtime system allows read and write access to configuration files"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CODESYS Control RTE (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.17.40"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control RTE (for Beckhoff CX) SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.17.40"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Win (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.17.40"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS HMI (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.17.40"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Development System V3",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.17.40"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Runtime System Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.17.40"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Embedded Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.17.40"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Remote Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.17.40"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for BeagleBone SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Beckhoff CX9020 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for emPC-A/iMX6 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for IOT2000 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Linux SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC100 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC200 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PLCnext SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Raspberry Pi SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for WAGO Touch Panels 600 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "CODESYS"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-668 Exposure of Resource to Wrong Sphere"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17089\u0026token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53\u0026download=",
              "refsource": "CONFIRM",
              "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17089\u0026token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53\u0026download="
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2022-22515",
    "datePublished": "2022-04-07T18:21:16.280553Z",
    "dateReserved": "2022-01-03T00:00:00",
    "dateUpdated": "2024-09-16T17:59:22.215Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-30792
Vulnerability from cvelistv5
Published
2022-07-11 10:40
Modified
2024-09-16 23:05
Summary
CODESYS: CmpChannelServer, CmpChannelServerEmbedded allow unauthenticated attackers to block all their available communication channels
Impacted products
Vendor Product Version
CODESYS CODESYS Control RTE (for Beckhoff CX) SL Version: V3   < V3.5.18.20
CODESYS CODESYS Control Win (SL) Version: V3   < V3.5.18.20
CODESYS CODESYS Gateway Version: V3   < V3.5.18.20
CODESYS CODESYS Edge Gateway for Windows Version: V3   < V3.5.18.20
CODESYS CODESYS HMI (SL) Version: V3   < V3.5.18.20
CODESYS CODESYS Development System V3 Version: V3   < V3.5.18.10
CODESYS CODESYS Control Runtime System Toolkit Version: V3   < V3.5.18.20
CODESYS CODESYS Embedded Target Visu Toolkit Version: V3   < V3.5.18.20
CODESYS CODESYS Remote Target Visu Toolkit Version: V3   < V3.5.18.20
CODESYS CODESYS Control for BeagleBone SL Version: V3   < V4.5.0.0
CODESYS CODESYS Control for Beckhoff CX9020 SL Version: V3   < V4.5.0.0
CODESYS CODESYS Control for emPC-A/iMX6 SL Version: V3   < V4.5.0.0
CODESYS CODESYS Control for IOT2000 SL Version: V3   < V4.5.0.0
CODESYS CODESYS Control for Linux SL Version: V3   < V4.5.0.0
CODESYS CODESYS Control for PFC100 SL Version: V3   < V4.5.0.0
CODESYS CODESYS Control for PFC200 SL Version: V3   < V4.5.0.0
CODESYS CODESYS Control for PLCnext SL Version: V3   < V4.5.0.0
CODESYS CODESYS Control for Raspberry Pi SL Version: V3   < V4.5.0.0
CODESYS CODESYS Control for WAGO Touch Panels 600 SL Version: V3   < V4.5.0.0
CODESYS CODESYS Edge Gateway for Linux Version: V3   < V4.5.0.0
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T07:03:38.599Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download="
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "CODESYS Control RTE (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control RTE (for Beckhoff CX) SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Win (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Gateway",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Edge Gateway for Windows",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS HMI (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Development System V3",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.10",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Runtime System Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Embedded Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Remote Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.18.20",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for BeagleBone SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Beckhoff CX9020 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for emPC-A/iMX6 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for IOT2000 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Linux SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC100 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC200 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PLCnext SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Raspberry Pi SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for WAGO Touch Panels 600 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Edge Gateway for Linux",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-07-08T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In CmpChannelServer of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new communication channel connections. Existing connections are not affected."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400 Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-11T10:40:43",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download="
        }
      ],
      "source": {
        "defect": [
          "CERT@VDE#",
          "64130"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "CODESYS: CmpChannelServer, CmpChannelServerEmbedded allow unauthenticated attackers to block all their available communication channels",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "DATE_PUBLIC": "2022-07-08T06:00:00.000Z",
          "ID": "CVE-2022-30792",
          "STATE": "PUBLIC",
          "TITLE": "CODESYS: CmpChannelServer, CmpChannelServerEmbedded allow unauthenticated attackers to block all their available communication channels"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CODESYS Control RTE (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control RTE (for Beckhoff CX) SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Win (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Gateway",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Edge Gateway for Windows",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS HMI (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Development System V3",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.10"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Runtime System Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Embedded Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Remote Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.18.20"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for BeagleBone SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Beckhoff CX9020 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for emPC-A/iMX6 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for IOT2000 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Linux SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC100 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC200 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PLCnext SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Raspberry Pi SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for WAGO Touch Panels 600 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Edge Gateway for Linux",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "CODESYS"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In CmpChannelServer of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new communication channel connections. Existing connections are not affected."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-400 Uncontrolled Resource Consumption"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download=",
              "refsource": "CONFIRM",
              "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download="
            }
          ]
        },
        "source": {
          "defect": [
            "CERT@VDE#",
            "64130"
          ],
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2022-30792",
    "datePublished": "2022-07-11T10:40:43.935648Z",
    "dateReserved": "2022-05-16T00:00:00",
    "dateUpdated": "2024-09-16T23:05:31.037Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}