All the vulnerabilites related to CODESYS - CODESYS PLCHandler
cve-2022-22517
Vulnerability from cvelistv5
Published
2022-04-07 18:21
Modified
2024-09-16 22:16
Severity ?
EPSS score ?
Summary
Communication Components in multiple CODESYS products vulnerable to communication channel disruption
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T03:14:55.454Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17091\u0026token=c450f8bbbd838c647d102f359356386c6ea5aeca\u0026download=" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "CODESYS Control RTE (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Control RTE (for Beckhoff CX) SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Control Win (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Gateway", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Edge Gateway for Windows", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS HMI (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Development System V3", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Control Runtime System Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Embedded Target Visu Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Remote Target Visu Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for BeagleBone SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for Beckhoff CX9020 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for emPC-A/iMX6 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for IOT2000 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for Linux SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for PFC100 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for PFC200 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for PLCnext SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for Raspberry Pi SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Control for WAGO Touch Panels 600 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS Edge Gateway for Linux", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V4.5.0.0", "versionType": "custom" } ] }, { "product": "CODESYS OPC DA Server SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] }, { "product": "CODESYS PLCHandler", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.0", "status": "affected", "version": "V3.5.18.0", "versionType": "custom" } ] } ], "datePublic": "2022-04-06T00:00:00", "descriptions": [ { "lang": "en", "value": "An unauthenticated, remote attacker can disrupt existing communication channels between CODESYS products by guessing a valid channel ID and injecting packets. This results in the communication channel to be closed." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-334", "description": "CWE-334 Small Space of Random Values", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-07T18:21:19", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17091\u0026token=c450f8bbbd838c647d102f359356386c6ea5aeca\u0026download=" } ], "source": { "discovery": "UNKNOWN" }, "title": "Communication Components in multiple CODESYS products vulnerable to communication channel disruption", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2022-04-06T10:00:00.000Z", "ID": "CVE-2022-22517", "STATE": "PUBLIC", "TITLE": "Communication Components in multiple CODESYS products vulnerable to communication channel disruption" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CODESYS Control RTE (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Control RTE (for Beckhoff CX) SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Control Win (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Gateway", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Edge Gateway for Windows", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS HMI (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Development System V3", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Control Runtime System Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Embedded Target Visu Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Remote Target Visu Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS Control for BeagleBone SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Beckhoff CX9020 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for emPC-A/iMX6 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for IOT2000 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Linux SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PFC100 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PFC200 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PLCnext SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Raspberry Pi SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for WAGO Touch Panels 600 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Edge Gateway for Linux", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V4.5.0.0", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS OPC DA Server SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } }, { "product_name": "CODESYS PLCHandler", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3.5.18.0", "version_value": "V3.5.18.0" } ] } } ] }, "vendor_name": "CODESYS" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An unauthenticated, remote attacker can disrupt existing communication channels between CODESYS products by guessing a valid channel ID and injecting packets. This results in the communication channel to be closed." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-334 Small Space of Random Values" } ] } ] }, "references": { "reference_data": [ { "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17091\u0026token=c450f8bbbd838c647d102f359356386c6ea5aeca\u0026download=", "refsource": "MISC", "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17091\u0026token=c450f8bbbd838c647d102f359356386c6ea5aeca\u0026download=" } ] }, "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2022-22517", "datePublished": "2022-04-07T18:21:20.091353Z", "dateReserved": "2022-01-03T00:00:00", "dateUpdated": "2024-09-16T22:16:04.923Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-31805
Vulnerability from cvelistv5
Published
2022-06-24 07:46
Modified
2024-09-16 18:55
Severity ?
EPSS score ?
Summary
Insecure transmission of credentials
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | CODESYS | CODESYS Development System |
Version: V2 < V2.3.9.69 Version: V3 < V3.5.18.30 |
||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:26:01.086Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17140\u0026token=6aa2c5c4a8b83b8b09936fefed5b0b11f9d2cc6c\u0026download=" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "CODESYS Development System", "vendor": "CODESYS", "versions": [ { "lessThan": "V2.3.9.69", "status": "affected", "version": "V2", "versionType": "custom" }, { "lessThan": "V3.5.18.30", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "CODESYS Gateway Client", "vendor": "CODESYS", "versions": [ { "lessThan": "V2.3.9.38", "status": "affected", "version": "V2", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "CODESYS Gateway Server", "vendor": "CODESYS", "versions": [ { "lessThan": "V2.3.9.38", "status": "affected", "version": "V2", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "CODESYS Web server", "vendor": "CODESYS", "versions": [ { "lessThan": "V1.1.9.23", "status": "affected", "version": "V1", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "CODESYS SP Realtime NT", "vendor": "CODESYS", "versions": [ { "lessThan": "V2.3.7.30", "status": "affected", "version": "V2", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "CODESYS PLCWinNT", "vendor": "CODESYS", "versions": [ { "lessThan": "V2.4.7.57", "status": "affected", "version": "V2", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "CODESYS Runtime Toolkit 32 bit full", "vendor": "CODESYS", "versions": [ { "lessThan": "V2.4.7.57", "status": "affected", "version": "V2", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "CODESYS Edge Gateway for Windows", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.30", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "CODESYS HMI (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.30", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "CODESYS OPC DA Server SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.30", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "CODESYS PLCHandler", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.30", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "CODESYS Gateway", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.30", "status": "affected", "version": "V3", "versionType": "custom" } ] } ], "datePublic": "2022-06-22T22:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003eIn the CODESYS Development System multiple components in multiple versions transmit the passwords for the communication between clients and servers unprotected.\u003c/p\u003e" } ], "value": "In the CODESYS Development System multiple components in multiple versions transmit the passwords for the communication between clients and servers unprotected." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-523", "description": "CWE-523 Unprotected Transport of Credentials", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-05-09T12:54:39.506Z", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17140\u0026token=6aa2c5c4a8b83b8b09936fefed5b0b11f9d2cc6c\u0026download=" } ], "source": { "defect": [ "CERT@VDE#", "64140" ], "discovery": "UNKNOWN" }, "title": "Insecure transmission of credentials", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2022-06-23T10:00:00.000Z", "ID": "CVE-2022-31805", "STATE": "PUBLIC", "TITLE": "Insecure transmission of credentials" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CODESYS Development System", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V2", "version_value": "V2.3.9.69" }, { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Gateway Client", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V2", "version_value": "V2.3.9.38" } ] } }, { "product_name": "CODESYS Gateway Server", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V2", "version_value": "V2.3.9.38" } ] } }, { "product_name": "CODESYS Web server", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V1", "version_value": "V1.1.9.23" } ] } }, { "product_name": "CODESYS SP Realtime NT", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V2", "version_value": "V2.3.7.30" } ] } }, { "product_name": "CODESYS PLCWinNT", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V2", "version_value": "V2.4.7.57" } ] } }, { "product_name": "CODESYS Runtime Toolkit 32 bit full", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V2", "version_value": "V2.4.7.57" } ] } }, { "product_name": "CODESYS Edge Gateway for Windows", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS HMI (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS OPC DA Server SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS PLCHandler", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Gateway", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } } ] }, "vendor_name": "CODESYS" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In the CODESYS Development System multiple components in multiple versions transmit the passwords for the communication between clients and servers unprotected." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-523 Unprotected Transport of Credentials" } ] } ] }, "references": { "reference_data": [ { "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17140\u0026token=6aa2c5c4a8b83b8b09936fefed5b0b11f9d2cc6c\u0026download=", "refsource": "CONFIRM", "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17140\u0026token=6aa2c5c4a8b83b8b09936fefed5b0b11f9d2cc6c\u0026download=" } ] }, "source": { "defect": [ "CERT@VDE#", "64140" ], "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2022-31805", "datePublished": "2022-06-24T07:46:15.076016Z", "dateReserved": "2022-05-30T00:00:00", "dateUpdated": "2024-09-16T18:55:26.939Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }