Vulnerabilites related to Tenda - AC9
var-201810-0273
Vulnerability from variot

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'deviceList' parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. A buffer overflow vulnerability exists in httpd in several Tenda products that an attacker can exploit to cause a denial of service (covering the return value of a function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0273",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac10",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac15",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac7",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac7 v15.03.06.44 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10 v15.03.06.23 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac15 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01888"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011964"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1354"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18727"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac10_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac7_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011964"
      }
    ]
  },
  "cve": "CVE-2018-18727",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-18727",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-01888",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-129315",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-18727",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-18727",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-18727",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-01888",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201810-1354",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-129315",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01888"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129315"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011964"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1354"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18727"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceList\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. A buffer overflow vulnerability exists in httpd in several Tenda products that an attacker can exploit to cause a denial of service (covering the return value of a function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-18727"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011964"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-01888"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129315"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-18727",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011964",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1354",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-01888",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-129315",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01888"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129315"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011964"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1354"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18727"
      }
    ]
  },
  "id": "VAR-201810-0273",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01888"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129315"
      }
    ],
    "trust": 1.4236169144444446
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01888"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:45:10.729000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011964"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-129315"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011964"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18727"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://github.com/zillr0/routers/blob/master/tenda/stack1.md"
      },
      {
        "trust": 1.4,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18727"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18727"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01888"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129315"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011964"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1354"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18727"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01888"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129315"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011964"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1354"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18727"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-01888"
      },
      {
        "date": "2018-10-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129315"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011964"
      },
      {
        "date": "2018-10-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1354"
      },
      {
        "date": "2018-10-29T12:29:07.400000",
        "db": "NVD",
        "id": "CVE-2018-18727"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-01888"
      },
      {
        "date": "2018-12-14T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129315"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011964"
      },
      {
        "date": "2018-10-31T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1354"
      },
      {
        "date": "2024-11-21T03:56:27.863000",
        "db": "NVD",
        "id": "CVE-2018-18727"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1354"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Product buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011964"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer overflow",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1354"
      }
    ],
    "trust": 0.6
  }
}

var-202203-1211
Vulnerability from variot

Tenda AC9 v15.03.2.21 was discovered to contain a buffer overflow via the time parameter in the saveparentcontrolinfo function. The Tenda AC9 is a wireless router from the Chinese company Tenda

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202203-1211",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.2.21"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.2.21"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24425"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25429"
      }
    ]
  },
  "cve": "CVE-2022-25429",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-25429",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-24425",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-25429",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-25429",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-24425",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202203-1858",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24425"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1858"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25429"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 v15.03.2.21 was discovered to contain a buffer overflow via the time parameter in the saveparentcontrolinfo function. The Tenda AC9 is a wireless router from the Chinese company Tenda",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25429"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-24425"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-25429",
        "trust": 2.2
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-24425",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1858",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24425"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1858"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25429"
      }
    ]
  },
  "id": "VAR-202203-1211",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24425"
      }
    ],
    "trust": 1.03844455
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24425"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:15:51.067000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC9 saveparentcontrolinfo function buffer overflow vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/328501"
      },
      {
        "title": "Tenda AC9 Fixes for command injection vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=186937"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24425"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1858"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25429"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://github.com/ephaha/iot_vuln/tree/main/tenda/ac9/1"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-25429"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-25429/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24425"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1858"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25429"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24425"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1858"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25429"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-02T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-24425"
      },
      {
        "date": "2022-03-18T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1858"
      },
      {
        "date": "2022-03-18T21:15:07.980000",
        "db": "NVD",
        "id": "CVE-2022-25429"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-03-31T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-24425"
      },
      {
        "date": "2022-03-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1858"
      },
      {
        "date": "2024-11-21T06:52:10.283000",
        "db": "NVD",
        "id": "CVE-2022-25429"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1858"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 saveparentcontrolinfo function buffer overflow vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24425"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "command injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1858"
      }
    ],
    "trust": 0.6
  }
}

var-202005-0458
Vulnerability from variot

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/setcfm funcpara1 parameter for a POST request, a value is directly used in a sprintf to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202005-0458",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.06.42_multi"
      },
      {
        "model": "ac6",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19_multi_td01"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19_multi_td01"
      },
      {
        "model": "ac15",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac6",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac6 v15.03.05.19 multi td01",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac9 v15.03.06.42 multi",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v3.0"
      },
      {
        "model": "ac15 v15.03.05.19 multi td01",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac18 ) cn",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19(6318"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31407"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005746"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13392"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tendacn:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac6_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005746"
      }
    ]
  },
  "cve": "CVE-2020-13392",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2020-13392",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.1,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 7.5,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-005746",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2020-31407",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2020-13392",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-005746",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-13392",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "JVNDB-2020-005746",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2020-31407",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202005-1142",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULMON",
            "id": "CVE-2020-13392",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31407"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13392"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005746"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1142"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13392"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the /goform/setcfm funcpara1 parameter for a POST request, a value is directly used in a sprintf to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-13392"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005746"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-31407"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13392"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-13392",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005746",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-31407",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1142",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13392",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31407"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13392"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005746"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1142"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13392"
      }
    ]
  },
  "id": "VAR-202005-0458",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31407"
      }
    ],
    "trust": 1.38075707625
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31407"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:16:28.744000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://tendacn.com/en"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005746"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005746"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13392"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://joel-malwarebenchmark.github.io/blog/2020/04/28/cve-2020-13392-tenda-vulnerability/"
      },
      {
        "trust": 2.0,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-13392"
      },
      {
        "trust": 1.7,
        "url": "https://joel-malwarebenchmark.github.io"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-13392"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/120.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31407"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13392"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005746"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1142"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13392"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31407"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13392"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005746"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1142"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13392"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-31407"
      },
      {
        "date": "2020-05-22T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-13392"
      },
      {
        "date": "2020-06-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-005746"
      },
      {
        "date": "2020-05-22T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-1142"
      },
      {
        "date": "2020-05-22T17:15:11.237000",
        "db": "NVD",
        "id": "CVE-2020-13392"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-31407"
      },
      {
        "date": "2020-05-27T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-13392"
      },
      {
        "date": "2020-06-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-005746"
      },
      {
        "date": "2020-05-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-1142"
      },
      {
        "date": "2024-11-21T05:01:10.107000",
        "db": "NVD",
        "id": "CVE-2020-13392"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1142"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Classic buffer overflow vulnerability in device",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005746"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1142"
      }
    ],
    "trust": 0.6
  }
}

var-201809-0931
Vulnerability from variot

An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN and AC10 V15.03.06.23_CN devices. The mac parameter in a POST request is used directly in a doSystemCmd call, causing OS command injection. Tenda AC9 and AC10 The device includes OS A command injection vulnerability exists.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. TendaAC9 is a wireless router product from Tenda. The operating system command injection vulnerability exists in TendaAC915.03.05.19 (6318)_CN version and AC1015.03.06.23_CN version and previous versions

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201809-0931",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tendacn",
        "version": "15.03.05.19"
      },
      {
        "model": "ac10",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.06.23"
      },
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac10 \u003c=15.03.06.23 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tendacn",
        "version": "15.03.06.23"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-19080"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009402"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-035"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16334"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tendacn:ac10_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009402"
      }
    ]
  },
  "cve": "CVE-2018-16334",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CVE-2018-16334",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CNVD-2018-19080",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "VHN-126683",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2018-16334",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-16334",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-16334",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-19080",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201809-035",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-126683",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-19080"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126683"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009402"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-035"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16334"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN and AC10 V15.03.06.23_CN devices. The mac parameter in a POST request is used directly in a doSystemCmd call, causing OS command injection. Tenda AC9 and AC10 The device includes OS A command injection vulnerability exists.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. TendaAC9 is a wireless router product from Tenda. The operating system command injection vulnerability exists in TendaAC915.03.05.19 (6318)_CN version and AC1015.03.06.23_CN version and previous versions",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-16334"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009402"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-19080"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126683"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-16334",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009402",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-035",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-19080",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-126683",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-19080"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126683"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009402"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-035"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16334"
      }
    ]
  },
  "id": "VAR-201809-0931",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-19080"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126683"
      }
    ],
    "trust": 1.3762350424999998
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-19080"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:12:20.639000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009402"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-78",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-126683"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009402"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16334"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-04/tenda.md"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-16334"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-16334"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-19080"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126683"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009402"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-035"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16334"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-19080"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126683"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009402"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-035"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16334"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-09-17T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-19080"
      },
      {
        "date": "2018-09-02T00:00:00",
        "db": "VULHUB",
        "id": "VHN-126683"
      },
      {
        "date": "2018-11-19T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-009402"
      },
      {
        "date": "2018-09-03T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201809-035"
      },
      {
        "date": "2018-09-02T03:29:00.760000",
        "db": "NVD",
        "id": "CVE-2018-16334"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-09-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-19080"
      },
      {
        "date": "2018-10-25T00:00:00",
        "db": "VULHUB",
        "id": "VHN-126683"
      },
      {
        "date": "2018-11-19T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-009402"
      },
      {
        "date": "2018-09-03T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201809-035"
      },
      {
        "date": "2024-11-21T03:52:32.727000",
        "db": "NVD",
        "id": "CVE-2018-16334"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-035"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 and  AC10 In the device  OS Command injection vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009402"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "operating system commend injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-035"
      }
    ],
    "trust": 0.6
  }
}

var-202208-2272
Vulnerability from variot

Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the time parameter at /goform/SetLEDCfg. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202208-2272",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac9  firmware  15.03.05.19"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015959"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36570"
      }
    ]
  },
  "cve": "CVE-2022-36570",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.2,
            "id": "CVE-2022-36570",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.2,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-36570",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "High",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-36570",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-36570",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202208-4522",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015959"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4522"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36570"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the time parameter at /goform/SetLEDCfg. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-36570"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015959"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-36570",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015959",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4522",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015959"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4522"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36570"
      }
    ]
  },
  "id": "VAR-202208-2272",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.43844455
  },
  "last_update_date": "2024-08-14T14:37:19.796000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015959"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36570"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/cyberunicorniot/iotvuln/blob/main/tenda_ac9/1/tenda_ac9_setledcfg.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-36570"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-36570/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015959"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4522"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36570"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015959"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4522"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36570"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-09-29T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-015959"
      },
      {
        "date": "2022-08-31T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202208-4522"
      },
      {
        "date": "2022-08-31T20:15:08.973000",
        "db": "NVD",
        "id": "CVE-2022-36570"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-09-29T08:06:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-015959"
      },
      {
        "date": "2022-09-05T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202208-4522"
      },
      {
        "date": "2022-09-02T22:10:48.783000",
        "db": "NVD",
        "id": "CVE-2022-36570"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4522"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015959"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4522"
      }
    ],
    "trust": 0.6
  }
}

var-201904-0689
Vulnerability from variot

An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router's web server (httpd). When processing the page parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, a causing buffer overflow. Tenda AC7 , AC9 , AC10 The firmware contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. Tenda AC7 and others are all wireless routers from China's Tenda. This vulnerability originates from a network system or product that incorrectly validates data boundaries when performing operations on memory, causing incorrect read and write operations to be associated with other memory locations

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201904-0689",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10",
        "scope": "lte",
        "trust": 1.8,
        "vendor": "tenda",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac7",
        "scope": "lte",
        "trust": 1.8,
        "vendor": "tenda",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac9",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac9",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac7 v15.03.06.44 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10 \u003c=v15.03.06.23 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 \u003c=v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-13772"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015358"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14557"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac10_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac7_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015358"
      }
    ]
  },
  "cve": "CVE-2018-14557",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-14557",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-13772",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-124728",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-14557",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-14557",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-14557",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-13772",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201904-1169",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-124728",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-13772"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124728"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015358"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-1169"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14557"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router\u0027s web server (httpd). When processing the page parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, a causing buffer overflow. Tenda AC7 , AC9 , AC10 The firmware contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. Tenda AC7 and others are all wireless routers from China\u0027s Tenda. This vulnerability originates from a network system or product that incorrectly validates data boundaries when performing operations on memory, causing incorrect read and write operations to be associated with other memory locations",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-14557"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015358"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-13772"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124728"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-14557",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015358",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-1169",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-13772",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-124728",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-13772"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124728"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015358"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-1169"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14557"
      }
    ]
  },
  "id": "VAR-201904-0689",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-13772"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124728"
      }
    ],
    "trust": 1.440988034
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "IoT"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-13772"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:52:20.456000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015358"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-124728"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015358"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14557"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-03/tenda.md"
      },
      {
        "trust": 2.0,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14557"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14557"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-13772"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124728"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015358"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-1169"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14557"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-13772"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124728"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015358"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-1169"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14557"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-05-10T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-13772"
      },
      {
        "date": "2019-04-25T00:00:00",
        "db": "VULHUB",
        "id": "VHN-124728"
      },
      {
        "date": "2019-05-29T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-015358"
      },
      {
        "date": "2019-04-25T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201904-1169"
      },
      {
        "date": "2019-04-25T20:29:00.240000",
        "db": "NVD",
        "id": "CVE-2018-14557"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-05-10T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-13772"
      },
      {
        "date": "2019-05-02T00:00:00",
        "db": "VULHUB",
        "id": "VHN-124728"
      },
      {
        "date": "2019-05-29T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-015358"
      },
      {
        "date": "2019-04-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201904-1169"
      },
      {
        "date": "2024-11-21T03:49:18.313000",
        "db": "NVD",
        "id": "CVE-2018-14557"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Buffer error vulnerability in product firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015358"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-1169"
      }
    ],
    "trust": 0.6
  }
}

var-202005-0456
Vulnerability from variot

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/addressNat entrys and mitInterface parameters for a POST request, a value is directly used in a sprintf to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202005-0456",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.06.42_multi"
      },
      {
        "model": "ac6",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19_multi_td01"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19_multi_td01"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "v1.0 15.03.05.19_multi_td01"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318_)_cn"
      },
      {
        "model": "ac6",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "v1.0 15.03.05.19_multi_td01"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "v1.0 15.03.05.19(6318)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "v3.0 15.03.06.42_multi"
      },
      {
        "model": "ac6 v15.03.05.19 multi td01",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac9 v15.03.06.42 multi",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v3.0"
      },
      {
        "model": "ac15 v15.03.05.19 multi td01",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac18 ) cn",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19(6318"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31387"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005758"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13390"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac6_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005758"
      }
    ]
  },
  "cve": "CVE-2020-13390",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2020-13390",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 7.5,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-005758",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2020-31387",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2020-13390",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-005758",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-13390",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "JVNDB-2020-005758",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2020-31387",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202005-1140",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31387"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005758"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1140"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13390"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the /goform/addressNat entrys and mitInterface parameters for a POST request, a value is directly used in a sprintf to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-13390"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005758"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-31387"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-13390",
        "trust": 3.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005758",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-31387",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1140",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31387"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005758"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1140"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13390"
      }
    ]
  },
  "id": "VAR-202005-0456",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31387"
      }
    ],
    "trust": 1.38075707625
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31387"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:29:37.793000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005758"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005758"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13390"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://joel-malwarebenchmark.github.io/blog/2020/04/28/cve-2020-13390-tenda-vulnerability/"
      },
      {
        "trust": 2.0,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-13390"
      },
      {
        "trust": 1.6,
        "url": "https://joel-malwarebenchmark.github.io"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-13390"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31387"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005758"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1140"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13390"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31387"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005758"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1140"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13390"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-31387"
      },
      {
        "date": "2020-06-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-005758"
      },
      {
        "date": "2020-05-22T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-1140"
      },
      {
        "date": "2020-05-22T17:15:11.097000",
        "db": "NVD",
        "id": "CVE-2020-13390"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-31387"
      },
      {
        "date": "2020-06-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-005758"
      },
      {
        "date": "2020-05-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-1140"
      },
      {
        "date": "2024-11-21T05:01:09.810000",
        "db": "NVD",
        "id": "CVE-2020-13390"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1140"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Classic buffer overflow vulnerability in device",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005758"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1140"
      }
    ],
    "trust": 0.6
  }
}

var-202308-3842
Vulnerability from variot

Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter wpapsk_crypto at url /goform/WifiExtraSet. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202308-3842",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "5.03.06.42_multi"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac9  firmware  5.03.06.42 multi"
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011114"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41554"
      }
    ]
  },
  "cve": "CVE-2023-41554",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-41554",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-41554",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-41554",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-41554",
            "trust": 0.8,
            "value": "Critical"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011114"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41554"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter wpapsk_crypto at url /goform/WifiExtraSet. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-41554"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011114"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-41554",
        "trust": 2.6
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011114",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011114"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41554"
      }
    ]
  },
  "id": "VAR-202308-3842",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.43844455
  },
  "last_update_date": "2024-08-14T14:36:41.204000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011114"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41554"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromsetwirelessrepeat/1.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-41554"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011114"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41554"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011114"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41554"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-12-12T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-011114"
      },
      {
        "date": "2023-08-30T13:15:13.417000",
        "db": "NVD",
        "id": "CVE-2023-41554"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-12-12T06:21:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-011114"
      },
      {
        "date": "2023-08-31T18:40:25.183000",
        "db": "NVD",
        "id": "CVE-2023-41554"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011114"
      }
    ],
    "trust": 0.8
  }
}

var-202408-1940
Vulnerability from variot

A Command Injection vulnerability exists in formWriteFacMac of the httpd binary in Tenda AC9 v15.03.06.42. As a result, attacker can execute OS commands with root privileges. Tenda AC9 is a wireless router from China's Tenda company.

Tenda AC9 has a security vulnerability caused by an unauthorized access flaw in the device firmware. Attackers can exploit this vulnerability to bypass authentication and gain management privileges on the device

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202408-1940",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-36344"
      }
    ]
  },
  "cve": "CVE-2024-42634",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2024-36344",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2024-42634",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "id": "CVE-2024-42634",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-36344",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-36344"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-42634"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A Command Injection vulnerability exists in formWriteFacMac of the httpd binary in Tenda AC9 v15.03.06.42. As a result, attacker can execute OS commands with root privileges. Tenda AC9 is a wireless router from China\u0027s Tenda company. \n\nTenda AC9 has a security vulnerability caused by an unauthorized access flaw in the device firmware. Attackers can exploit this vulnerability to bypass authentication and gain management privileges on the device",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-42634"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-36344"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-42634",
        "trust": 1.6
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-36344",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-36344"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-42634"
      }
    ]
  },
  "id": "VAR-202408-1940",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-36344"
      }
    ],
    "trust": 1.03844455
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-36344"
      }
    ]
  },
  "last_update_date": "2024-08-24T23:03:19.787000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC9 has an unspecified vulnerability (CNVD-2024-36344)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/583666"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-36344"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-94",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-42634"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://github.com/goldds96/report/blob/main/tenda/ac9/ci.md"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-36344"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-42634"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-36344"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-42634"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-08-22T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-36344"
      },
      {
        "date": "2024-08-16T16:15:06.670000",
        "db": "NVD",
        "id": "CVE-2024-42634"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-08-23T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-36344"
      },
      {
        "date": "2024-08-19T13:00:23.117000",
        "db": "NVD",
        "id": "CVE-2024-42634"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 has an unspecified vulnerability (CNVD-2024-36344)",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-36344"
      }
    ],
    "trust": 0.6
  }
}

var-202410-1497
Vulnerability from variot

A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. AC15 firmware, AC7 firmware, ac10u firmware etc. The product has NULL There is a vulnerability in pointer dereference.Service operation interruption (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202410-1497",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac1206",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.23"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.48.23"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.2.13"
      },
      {
        "model": "ac500",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "1.0.0.16"
      },
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.10.20"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.42"
      },
      {
        "model": "ac8",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.34.09"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.44"
      },
      {
        "model": "ac500",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "1.0.0.14"
      },
      {
        "model": "ac500",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "2.0.1.9\\(1307\\)"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.18"
      },
      {
        "model": "ac8",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.34.06"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.48.19"
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.48"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.05"
      },
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.10.13"
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.49"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.14"
      },
      {
        "model": "ac6",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.23"
      },
      {
        "model": "ac10",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac7",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac15",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac1206",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac6",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac500",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-011851"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-10280"
      }
    ]
  },
  "cve": "CVE-2024-10280",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.0,
            "id": "CVE-2024-10280",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "Single",
            "author": "OTHER",
            "availabilityImpact": "Complete",
            "baseScore": 6.8,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "JVNDB-2024-011851",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "id": "CVE-2024-10280",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2024-10280",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "JVNDB-2024-011851",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-10280",
            "trust": 1.0,
            "value": "High"
          },
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2024-10280",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2024-011851",
            "trust": 0.8,
            "value": "High"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-011851"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-10280"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-10280"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. AC15 firmware, AC7 firmware, ac10u firmware etc. The product has NULL There is a vulnerability in pointer dereference.Service operation interruption (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-10280"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-011851"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-10280",
        "trust": 2.6
      },
      {
        "db": "VULDB",
        "id": "281555",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-011851",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-011851"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-10280"
      }
    ]
  },
  "id": "VAR-202410-1497",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.4059792066666667
  },
  "last_update_date": "2024-11-07T22:35:04.235000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-476",
        "trust": 1.0
      },
      {
        "problemtype": "NULL Pointer dereference (CWE-476) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-011851"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-10280"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/johenanli/router_vuls/blob/main/websreadevent/websreadevent.md"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?id.281555"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?submit.426417"
      },
      {
        "trust": 1.8,
        "url": "https://www.tenda.com.cn/"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.281555"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-10280"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-011851"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-10280"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-011851"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-10280"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-11-05T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-011851"
      },
      {
        "date": "2024-10-23T14:15:04.500000",
        "db": "NVD",
        "id": "CVE-2024-10280"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-11-05T02:27:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-011851"
      },
      {
        "date": "2024-11-01T14:03:20.267000",
        "db": "NVD",
        "id": "CVE-2024-10280"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 In the product \u00a0NULL\u00a0 Pointer dereference vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-011851"
      }
    ],
    "trust": 0.8
  }
}

var-202203-1210
Vulnerability from variot

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the deviceId parameter in the saveparentcontrolinfo function. The Tenda AC9 is a wireless router from the Chinese company Tenda

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202203-1210",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.2.21"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.2.21"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24426"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25428"
      }
    ]
  },
  "cve": "CVE-2022-25428",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-25428",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-24426",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-25428",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-25428",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-24426",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202203-1859",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24426"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1859"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25428"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the deviceId parameter in the saveparentcontrolinfo function. The Tenda AC9 is a wireless router from the Chinese company Tenda",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25428"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-24426"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-25428",
        "trust": 2.2
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-24426",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1859",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24426"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1859"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25428"
      }
    ]
  },
  "id": "VAR-202203-1210",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24426"
      }
    ],
    "trust": 1.03844455
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24426"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:29:02.711000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC9 saveparentcontrolinfo function stack overflow vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/328506"
      },
      {
        "title": "Tenda AC9 Fixes for command injection vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=186938"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24426"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1859"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25428"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://github.com/ephaha/iot_vuln/tree/main/tenda/ac9/3"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-25428"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-25428/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24426"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1859"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25428"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24426"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1859"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25428"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-02T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-24426"
      },
      {
        "date": "2022-03-18T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1859"
      },
      {
        "date": "2022-03-18T21:15:07.943000",
        "db": "NVD",
        "id": "CVE-2022-25428"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-03-31T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-24426"
      },
      {
        "date": "2022-03-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1859"
      },
      {
        "date": "2024-11-21T06:52:10.150000",
        "db": "NVD",
        "id": "CVE-2022-25428"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1859"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 saveparentcontrolinfo function stack overflow vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24426"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "command injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1859"
      }
    ],
    "trust": 0.6
  }
}

var-202203-0587
Vulnerability from variot

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetStaticRoutecfg function. The Tenda AC9 is a wireless router from the Chinese company Tenda.

There is a buffer overflow vulnerability in Tenda AC9 15.03.2.21. The vulnerability arises from the fact that when the list parameter in the SetStaticRoutecfg function performs operations on memory, the data boundary is not properly verified. An attacker can exploit this vulnerability to execute arbitrary commands

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202203-0587",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.2.21"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.2.21"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26244"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25435"
      }
    ]
  },
  "cve": "CVE-2022-25435",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-25435",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-26244",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-25435",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-25435",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-26244",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202203-1852",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26244"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1852"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25435"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetStaticRoutecfg function. The Tenda AC9 is a wireless router from the Chinese company Tenda. \n\r\n\r\nThere is a buffer overflow vulnerability in Tenda AC9 15.03.2.21. The vulnerability arises from the fact that when the list parameter in the SetStaticRoutecfg function performs operations on memory, the data boundary is not properly verified. An attacker can exploit this vulnerability to execute arbitrary commands",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25435"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-26244"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-25435",
        "trust": 2.2
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-26244",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1852",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26244"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1852"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25435"
      }
    ]
  },
  "id": "VAR-202203-0587",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26244"
      }
    ],
    "trust": 1.03844455
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26244"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:29:06.854000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC9 Buffer Overflow Vulnerability (CNVD-2022-26244)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/328721"
      },
      {
        "title": "Tenda AC9 Fixes for command injection vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=186933"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26244"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1852"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25435"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.2,
        "url": "https://github.com/ephaha/iot_vuln/tree/main/tenda/ac9/7"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-25435/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26244"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1852"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25435"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26244"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1852"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25435"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-06T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-26244"
      },
      {
        "date": "2022-03-18T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1852"
      },
      {
        "date": "2022-03-18T21:15:08.130000",
        "db": "NVD",
        "id": "CVE-2022-25435"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-06T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-26244"
      },
      {
        "date": "2022-03-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1852"
      },
      {
        "date": "2024-11-21T06:52:10.793000",
        "db": "NVD",
        "id": "CVE-2022-25435"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1852"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 Buffer Overflow Vulnerability (CNVD-2022-26244)",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26244"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "command injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1852"
      }
    ],
    "trust": 0.6
  }
}

var-202308-3957
Vulnerability from variot

Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware and AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202308-3957",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac5",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.28"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.42_multi"
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac5",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011501"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41561"
      }
    ]
  },
  "cve": "CVE-2023-41561",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-41561",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-41561",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-41561",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-41561",
            "trust": 0.8,
            "value": "Critical"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011501"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41561"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware and AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-41561"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011501"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-41561",
        "trust": 2.6
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011501",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011501"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41561"
      }
    ]
  },
  "id": "VAR-202308-3957",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.43844455
  },
  "last_update_date": "2024-08-14T15:00:06.542000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011501"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41561"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/peris-navince/founded-0-days/blob/main/formsetpptpserver/1.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-41561"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011501"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41561"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011501"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41561"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-12-13T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-011501"
      },
      {
        "date": "2023-08-30T13:15:14.483000",
        "db": "NVD",
        "id": "CVE-2023-41561"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-12-13T07:04:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-011501"
      },
      {
        "date": "2023-09-01T20:16:09.883000",
        "db": "NVD",
        "id": "CVE-2023-41561"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 firmware and \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011501"
      }
    ],
    "trust": 0.8
  }
}

var-202204-1411
Vulnerability from variot

There is a stack overflow vulnerability in the SetSysTimeCfg() function in the httpd service of Tenda AC9 V15.03.2.21_cn. The attacker can obtain a stable root shell through a constructed payload. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202204-1411",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.2.21_cn"
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac9  firmware  15.03.2.21 cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 v15.03.2.21 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-38543"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-007904"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-27022"
      }
    ]
  },
  "cve": "CVE-2022-27022",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-27022",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-38543",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-27022",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-27022",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-27022",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-27022",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-38543",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202204-2599",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-38543"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-007904"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-2599"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-27022"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "There is a stack overflow vulnerability in the SetSysTimeCfg() function in the httpd service of Tenda AC9 V15.03.2.21_cn. The attacker can obtain a stable root shell through a constructed payload. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-27022"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-007904"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-38543"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-27022",
        "trust": 3.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-007904",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-38543",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-2599",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-38543"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-007904"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-2599"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-27022"
      }
    ]
  },
  "id": "VAR-202204-1411",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-38543"
      }
    ],
    "trust": 1.319222275
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-38543"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:54:36.503000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-007904"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-27022"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/ephaha/iot_vuln/tree/main/tenda/ac9/14"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-27022"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-27022/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-38543"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-007904"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-2599"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-27022"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-38543"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-007904"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-2599"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-27022"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-05-20T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-38543"
      },
      {
        "date": "2023-07-21T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-007904"
      },
      {
        "date": "2022-04-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202204-2599"
      },
      {
        "date": "2022-04-07T16:15:07.667000",
        "db": "NVD",
        "id": "CVE-2022-27022"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-05-20T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-38543"
      },
      {
        "date": "2023-07-21T08:17:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-007904"
      },
      {
        "date": "2022-04-15T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202204-2599"
      },
      {
        "date": "2024-11-21T06:55:00.767000",
        "db": "NVD",
        "id": "CVE-2022-27022"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-2599"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-007904"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-2599"
      }
    ],
    "trust": 0.6
  }
}

var-202203-0588
Vulnerability from variot

Tenda AC9 v15.03.2.21 was discovered to contain a remote command execution (RCE) vulnerability via the SetIPTVCfg function. The Tenda AC9 is a wireless router from the Chinese company Tenda. The vulnerability stems from the fact that the dosystemcmd parameter in the sub_a3550 function fails to properly filter the special elements that construct the code segment

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202203-0588",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.2.21"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.2.21"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26241"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25438"
      }
    ]
  },
  "cve": "CVE-2022-25438",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-25438",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-26241",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-25438",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-25438",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-26241",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202203-1850",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26241"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1850"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25438"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 v15.03.2.21 was discovered to contain a remote command execution (RCE) vulnerability via the SetIPTVCfg function. The Tenda AC9 is a wireless router from the Chinese company Tenda. The vulnerability stems from the fact that the dosystemcmd parameter in the sub_a3550 function fails to properly filter the special elements that construct the code segment",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25438"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-26241"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-25438",
        "trust": 2.2
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-26241",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1850",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26241"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1850"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25438"
      }
    ]
  },
  "id": "VAR-202203-0588",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26241"
      }
    ],
    "trust": 1.03844455
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26241"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:24:57.863000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC9 Command Injection Vulnerability (CNVD-2022-26241)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/328736"
      },
      {
        "title": "Tenda AC9 Fixes for command injection vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=186931"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26241"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1850"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-78",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25438"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.2,
        "url": "https://github.com/ephaha/iot_vuln/tree/main/tenda/ac9/11"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-25438/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26241"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1850"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25438"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26241"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1850"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25438"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-06T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-26241"
      },
      {
        "date": "2022-03-18T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1850"
      },
      {
        "date": "2022-03-18T21:15:08.210000",
        "db": "NVD",
        "id": "CVE-2022-25438"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-06T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-26241"
      },
      {
        "date": "2022-03-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1850"
      },
      {
        "date": "2024-11-21T06:52:11.070000",
        "db": "NVD",
        "id": "CVE-2022-25438"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1850"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 Command Injection Vulnerability (CNVD-2022-26241)",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26241"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "command injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1850"
      }
    ],
    "trust": 0.6
  }
}

var-202203-1216
Vulnerability from variot

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the ntpserver parameter in the SetSysTimeCfg function. The Tenda AC9 is a wireless router from the Chinese company Tenda.

A buffer overflow vulnerability exists in Tenda AC9 version 15.03.2.21. The vulnerability arises from the fact that when the ntpserver parameter in the SetSysTimeCfg function performs operations on memory, the data boundary is not properly verified. An attacker can exploit this vulnerability to cause arbitrary command execution

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202203-1216",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.2.21"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.2.21"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26243"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25440"
      }
    ]
  },
  "cve": "CVE-2022-25440",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-25440",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-26243",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-25440",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-25440",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-26243",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202203-1848",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26243"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1848"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25440"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the ntpserver parameter in the SetSysTimeCfg function. The Tenda AC9 is a wireless router from the Chinese company Tenda. \n\r\n\r\nA buffer overflow vulnerability exists in Tenda AC9 version 15.03.2.21. The vulnerability arises from the fact that when the ntpserver parameter in the SetSysTimeCfg function performs operations on memory, the data boundary is not properly verified. An attacker can exploit this vulnerability to cause arbitrary command execution",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25440"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-26243"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-25440",
        "trust": 2.2
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-26243",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1848",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26243"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1848"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25440"
      }
    ]
  },
  "id": "VAR-202203-1216",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26243"
      }
    ],
    "trust": 1.03844455
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26243"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:50:51.362000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC9 Buffer Overflow Vulnerability (CNVD-2022-26243)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/328726"
      },
      {
        "title": "Tenda AC9 Fixes for command injection vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=186929"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26243"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1848"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25440"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.2,
        "url": "https://github.com/ephaha/iot_vuln/tree/main/tenda/ac9/13"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-25440/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26243"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1848"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25440"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26243"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1848"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25440"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-06T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-26243"
      },
      {
        "date": "2022-03-18T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1848"
      },
      {
        "date": "2022-03-18T21:15:08.283000",
        "db": "NVD",
        "id": "CVE-2022-25440"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-06T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-26243"
      },
      {
        "date": "2022-03-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1848"
      },
      {
        "date": "2024-11-21T06:52:11.337000",
        "db": "NVD",
        "id": "CVE-2022-25440"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1848"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 Buffer Overflow Vulnerability (CNVD-2022-26243)",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26243"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "command injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1848"
      }
    ],
    "trust": 0.6
  }
}

var-202308-4017
Vulnerability from variot

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware, AC7 firmware, AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202308-4017",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac5",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.28"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "5.03.06.42_multi"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.44"
      },
      {
        "model": "ac5",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac7",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011083"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41556"
      }
    ]
  },
  "cve": "CVE-2023-41556",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-41556",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-41556",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-41556",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-41556",
            "trust": 0.8,
            "value": "Critical"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011083"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41556"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware, AC7 firmware, AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-41556"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011083"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-41556",
        "trust": 2.6
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011083",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011083"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41556"
      }
    ]
  },
  "id": "VAR-202308-4017",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.43844455
  },
  "last_update_date": "2024-08-14T15:05:27.688000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011083"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41556"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromsetipmacbind/1.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-41556"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011083"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41556"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011083"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41556"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-12-12T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-011083"
      },
      {
        "date": "2023-08-30T13:15:13.697000",
        "db": "NVD",
        "id": "CVE-2023-41556"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-12-12T05:53:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-011083"
      },
      {
        "date": "2023-08-31T18:40:18.453000",
        "db": "NVD",
        "id": "CVE-2023-41556"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011083"
      }
    ],
    "trust": 0.8
  }
}

var-202402-0826
Vulnerability from variot

Buffer Overflow vulnerability in the function setSchedWifi in Tenda AC9 v.3.0, firmware version v.15.03.06.42_multi allows a remote attacker to cause a denial of service or run arbitrary code via crafted overflow data. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.

Tenda AC9 has a buffer overflow vulnerability. The vulnerability stems from the failure of the setSchedWifi function to correctly verify the length of input data

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202402-0826",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.42_multi"
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac9  firmware  15.03.06.42 multi"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "3.0"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14374"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002610"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-24543"
      }
    ]
  },
  "cve": "CVE-2024-24543",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2024-14374",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2024-24543",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2024-24543",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2024-24543",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2024-24543",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-14374",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14374"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002610"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-24543"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Buffer Overflow vulnerability in the function setSchedWifi in Tenda AC9 v.3.0, firmware version v.15.03.06.42_multi allows a remote attacker to cause a denial of service or run arbitrary code via crafted overflow data. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\r\n\r\nTenda AC9 has a buffer overflow vulnerability. The vulnerability stems from the failure of the setSchedWifi function to correctly verify the length of input data",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-24543"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002610"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-14374"
      },
      {
        "db": "VULMON",
        "id": "CVE-2024-24543"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-24543",
        "trust": 3.3
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002610",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-14374",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2024-24543",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14374"
      },
      {
        "db": "VULMON",
        "id": "CVE-2024-24543"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002610"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-24543"
      }
    ]
  },
  "id": "VAR-202402-0826",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14374"
      }
    ],
    "trust": 1.03844455
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14374"
      }
    ]
  },
  "last_update_date": "2024-08-14T15:15:33.818000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC9 buffer overflow vulnerability (CNVD-2024-14374)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/534936"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14374"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002610"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-24543"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://github.com/timeseg/iot_cve/blob/main/tenda/ac9v3/0130/setschedwifi.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-24543"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14374"
      },
      {
        "db": "VULMON",
        "id": "CVE-2024-24543"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002610"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-24543"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14374"
      },
      {
        "db": "VULMON",
        "id": "CVE-2024-24543"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002610"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-24543"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-21T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-14374"
      },
      {
        "date": "2024-02-05T00:00:00",
        "db": "VULMON",
        "id": "CVE-2024-24543"
      },
      {
        "date": "2024-02-16T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-002610"
      },
      {
        "date": "2024-02-05T21:15:12.073000",
        "db": "NVD",
        "id": "CVE-2024-24543"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-21T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-14374"
      },
      {
        "date": "2024-02-06T00:00:00",
        "db": "VULMON",
        "id": "CVE-2024-24543"
      },
      {
        "date": "2024-02-16T01:03:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-002610"
      },
      {
        "date": "2024-02-14T17:13:32.827000",
        "db": "NVD",
        "id": "CVE-2024-24543"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-002610"
      }
    ],
    "trust": 0.8
  }
}

var-202308-3781
Vulnerability from variot

Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function. AC10 firmware, ac1206 firmware, AC6 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202308-3781",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac5",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.28"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.42_multi"
      },
      {
        "model": "fh1205",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "2.0.0.7\\(775\\)"
      },
      {
        "model": "ac1206",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.23"
      },
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.23"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.44"
      },
      {
        "model": "ac6",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.23"
      },
      {
        "model": "f1203",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "2.0.1.6"
      },
      {
        "model": "fh1203",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "2.0.1.6"
      },
      {
        "model": "ac1206",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "fh1203",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac6",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac5",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "fh1205",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "f1203",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac7",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021661"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38933"
      }
    ]
  },
  "cve": "CVE-2023-38933",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-38933",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-38933",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-38933",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-38933",
            "trust": 0.8,
            "value": "Critical"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021661"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38933"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function. AC10 firmware, ac1206 firmware, AC6 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-38933"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021661"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-38933",
        "trust": 2.6
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021661",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021661"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38933"
      }
    ]
  },
  "id": "VAR-202308-3781",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.3288697725
  },
  "last_update_date": "2024-08-14T13:19:52.824000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021661"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38933"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/formsetclientstate/readme.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-38933"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021661"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38933"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021661"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38933"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-01-19T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-021661"
      },
      {
        "date": "2023-08-07T19:15:11.133000",
        "db": "NVD",
        "id": "CVE-2023-38933"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-01-19T07:51:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-021661"
      },
      {
        "date": "2023-08-10T17:17:41.653000",
        "db": "NVD",
        "id": "CVE-2023-38933"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021661"
      }
    ],
    "trust": 0.8
  }
}

var-202308-4129
Vulnerability from variot

Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter firewallEn at url /goform/SetFirewallCfg. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202308-4129",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.42_multi"
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac9  firmware  15.03.06.42 multi"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011502"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41560"
      }
    ]
  },
  "cve": "CVE-2023-41560",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-41560",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-41560",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-41560",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-41560",
            "trust": 0.8,
            "value": "Critical"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011502"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41560"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter firewallEn at url /goform/SetFirewallCfg. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-41560"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011502"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-41560",
        "trust": 2.6
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011502",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011502"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41560"
      }
    ]
  },
  "id": "VAR-202308-4129",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.43844455
  },
  "last_update_date": "2024-08-14T15:26:26.183000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011502"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41560"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/peris-navince/founded-0-days/blob/main/formsetfirewallcfg/1.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-41560"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011502"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41560"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011502"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41560"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-12-13T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-011502"
      },
      {
        "date": "2023-08-30T13:15:14.390000",
        "db": "NVD",
        "id": "CVE-2023-41560"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-12-13T07:06:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-011502"
      },
      {
        "date": "2023-09-01T20:11:06.583000",
        "db": "NVD",
        "id": "CVE-2023-41560"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011502"
      }
    ],
    "trust": 0.8
  }
}

var-202005-0459
Vulnerability from variot

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/saveParentControlInfo deviceId and time parameters for a POST request, a value is directly used in a strcpy to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202005-0459",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.06.42_multi"
      },
      {
        "model": "ac6",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19_multi_td01"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19_multi_td01"
      },
      {
        "model": "ac15",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac6",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac6 v15.03.05.19 multi td01",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac9 v15.03.06.42 multi",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v3.0"
      },
      {
        "model": "ac15 v15.03.05.19 multi td01",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac18 ) cn",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19(6318"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31408"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005747"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13393"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tendacn:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac6_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005747"
      }
    ]
  },
  "cve": "CVE-2020-13393",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2020-13393",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 7.5,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-005747",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2020-31408",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2020-13393",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-005747",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-13393",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "JVNDB-2020-005747",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2020-31408",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202005-1143",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31408"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005747"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1143"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13393"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the /goform/saveParentControlInfo deviceId and time parameters for a POST request, a value is directly used in a strcpy to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-13393"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005747"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-31408"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-13393",
        "trust": 3.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005747",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-31408",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1143",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31408"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005747"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1143"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13393"
      }
    ]
  },
  "id": "VAR-202005-0459",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31408"
      }
    ],
    "trust": 1.38075707625
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31408"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:51:21.819000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://tendacn.com/en"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005747"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005747"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13393"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://joel-malwarebenchmark.github.io/blog/2020/04/28/cve-2020-13393-tenda-vulnerability/"
      },
      {
        "trust": 2.0,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-13393"
      },
      {
        "trust": 1.0,
        "url": "https://joel-malwarebenchmark.github.io"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-13393"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31408"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005747"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1143"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13393"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31408"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005747"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1143"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13393"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-31408"
      },
      {
        "date": "2020-06-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-005747"
      },
      {
        "date": "2020-05-22T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-1143"
      },
      {
        "date": "2020-05-22T17:15:11.300000",
        "db": "NVD",
        "id": "CVE-2020-13393"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-31408"
      },
      {
        "date": "2020-06-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-005747"
      },
      {
        "date": "2020-05-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-1143"
      },
      {
        "date": "2024-11-21T05:01:10.260000",
        "db": "NVD",
        "id": "CVE-2020-13393"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1143"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Classic buffer overflow vulnerability in device",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005747"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1143"
      }
    ],
    "trust": 0.6
  }
}

var-202202-1149
Vulnerability from variot

A vulnerability was discovered in Tenda AC9 v3.0 V15.03.06.42_multi and Tenda AC9 V1.0 V15.03.05.19(6318)_CN which allows for remote code execution via shell metacharacters in the guestuser field to the __fastcall function with a POST request. Tenda AC9 Exists in unspecified vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC9 is a wireless router from the Chinese company Tenda. No detailed vulnerability details are currently provided

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202202-1149",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.42_multi"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac9  firmware  1.0 v15.03.05.19(6318)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac9  firmware  3.0 v15.03.06.42_multi"
      },
      {
        "model": "ac9 15.03.06.42 multi",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-21234"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005711"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-26728"
      }
    ]
  },
  "cve": "CVE-2020-26728",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2020-26728",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-21234",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2020-26728",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2020-26728",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-26728",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2020-26728",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-21234",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202202-1089",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-21234"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005711"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1089"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-26728"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability was discovered in Tenda AC9 v3.0 V15.03.06.42_multi and Tenda AC9 V1.0 V15.03.05.19(6318)_CN which allows for remote code execution via shell metacharacters in the guestuser field to the __fastcall function with a POST request. Tenda AC9 Exists in unspecified vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC9 is a wireless router from the Chinese company Tenda. No detailed vulnerability details are currently provided",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-26728"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005711"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-21234"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-26728",
        "trust": 3.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005711",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-21234",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1089",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-21234"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005711"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1089"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-26728"
      }
    ]
  },
  "id": "VAR-202202-1149",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-21234"
      }
    ],
    "trust": 1.319222275
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-21234"
      }
    ]
  },
  "last_update_date": "2024-08-14T14:37:40.036000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top\u00a0Page",
        "trust": 0.8,
        "url": "https://www.tendacn.com/default.html"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005711"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "NVD-CWE-noinfo",
        "trust": 1.0
      },
      {
        "problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005711"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-26728"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/lyc-heng/routers/blob/a80b30bccfc9b76f3a4868ff28ad5ce2e0fca180/routers/rce1.md"
      },
      {
        "trust": 2.2,
        "url": "https://github.com/lyc-heng/router/blob/main/tenda/rce1.md"
      },
      {
        "trust": 1.6,
        "url": "https://github.com/lyc-heng/routers/blob/main/routers/rce1.md"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26728"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-21234"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005711"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1089"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-26728"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-21234"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005711"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1089"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-26728"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-03-21T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-21234"
      },
      {
        "date": "2023-06-09T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-005711"
      },
      {
        "date": "2022-02-11T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202202-1089"
      },
      {
        "date": "2022-02-11T19:15:08.027000",
        "db": "NVD",
        "id": "CVE-2020-26728"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-03-21T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-21234"
      },
      {
        "date": "2023-06-09T04:31:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-005711"
      },
      {
        "date": "2022-03-10T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202202-1089"
      },
      {
        "date": "2022-02-22T18:03:21.923000",
        "db": "NVD",
        "id": "CVE-2020-26728"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1089"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0AC9\u00a0 Vulnerability in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005711"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1089"
      }
    ],
    "trust": 0.6
  }
}

var-202203-0586
Vulnerability from variot

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the urls parameter in the saveparentcontrolinfo function. The Tenda AC9 is a wireless router from the Chinese company Tenda

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202203-0586",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.2.21"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.2.21"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-25785"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25433"
      }
    ]
  },
  "cve": "CVE-2022-25433",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-25433",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-25785",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-25433",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-25433",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-25785",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202203-1854",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-25785"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1854"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25433"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the urls parameter in the saveparentcontrolinfo function. The Tenda AC9 is a wireless router from the Chinese company Tenda",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25433"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-25785"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-25433",
        "trust": 2.2
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-25785",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1854",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-25785"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1854"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25433"
      }
    ]
  },
  "id": "VAR-202203-0586",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-25785"
      }
    ],
    "trust": 1.03844455
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-25785"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:04:57.246000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC9 saveparentcontrolinfo function stack overflow vulnerability (CNVD-2022-25785)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/328511"
      },
      {
        "title": "Tenda AC9 Fixes for command injection vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=186935"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-25785"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1854"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25433"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://github.com/ephaha/iot_vuln/tree/main/tenda/ac9/5"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-25433"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-25433/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-25785"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1854"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25433"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-25785"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1854"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25433"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-02T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-25785"
      },
      {
        "date": "2022-03-18T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1854"
      },
      {
        "date": "2022-03-18T21:15:08.057000",
        "db": "NVD",
        "id": "CVE-2022-25433"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-02T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-25785"
      },
      {
        "date": "2022-03-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1854"
      },
      {
        "date": "2024-11-21T06:52:10.540000",
        "db": "NVD",
        "id": "CVE-2022-25433"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1854"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 saveparentcontrolinfo function stack overflow vulnerability (CNVD-2022-25785)",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-25785"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "command injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1854"
      }
    ],
    "trust": 0.6
  }
}

var-202204-0934
Vulnerability from variot

There is a stack overflow vulnerability in the SetStaticRouteCfg() function in the httpd service of Tenda AC9 15.03.2.21_cn. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. An attacker can exploit the vulnerability to gain a stable root shell by constructing a payload

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202204-0934",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.2.21_cn"
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac9  firmware  15.03.2.21 cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 v15.03.2.21 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-38542"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-007905"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-27016"
      }
    ]
  },
  "cve": "CVE-2022-27016",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-27016",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2022-38542",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-27016",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-27016",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-27016",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-27016",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-38542",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202204-2592",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-38542"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-007905"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-2592"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-27016"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "There is a stack overflow vulnerability in the SetStaticRouteCfg() function in the httpd service of Tenda AC9 15.03.2.21_cn. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. An attacker can exploit the vulnerability to gain a stable root shell by constructing a payload",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-27016"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-007905"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-38542"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-27016",
        "trust": 3.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-007905",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-38542",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-2592",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-38542"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-007905"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-2592"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-27016"
      }
    ]
  },
  "id": "VAR-202204-0934",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-38542"
      }
    ],
    "trust": 1.319222275
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-38542"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:43:58.345000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-007905"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-27016"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/ephaha/iot_vuln/tree/main/tenda/ac9/10"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-27016"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-27016/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-38542"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-007905"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-2592"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-27016"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-38542"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-007905"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-2592"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-27016"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-05-20T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-38542"
      },
      {
        "date": "2023-07-21T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-007905"
      },
      {
        "date": "2022-04-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202204-2592"
      },
      {
        "date": "2022-04-07T15:15:08.430000",
        "db": "NVD",
        "id": "CVE-2022-27016"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-05-20T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-38542"
      },
      {
        "date": "2023-07-21T08:17:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-007905"
      },
      {
        "date": "2022-04-15T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202204-2592"
      },
      {
        "date": "2024-11-21T06:55:00.560000",
        "db": "NVD",
        "id": "CVE-2022-27016"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-2592"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-007905"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-2592"
      }
    ],
    "trust": 0.6
  }
}

var-201810-0245
Vulnerability from variot

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromAddressNat" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. An attacker could exploit the vulnerability to cause a denial of service (the return address of the override function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0245",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.05.19_cn"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac7 v15.03.06.44 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10 v15.03.06.23 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac15 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-22313"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011967"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1339"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18708"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac10_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac7_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011967"
      }
    ]
  },
  "cve": "CVE-2018-18708",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-18708",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2018-22313",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-129294",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-18708",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-18708",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-18708",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-22313",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201810-1339",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-129294",
            "trust": 0.1,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2018-18708",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-22313"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129294"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-18708"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011967"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1339"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18708"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromAddressNat\" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. An attacker could exploit the vulnerability to cause a denial of service (the return address of the override function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-18708"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011967"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-22313"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129294"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-18708"
      }
    ],
    "trust": 2.34
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-18708",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011967",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1339",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-22313",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-129294",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-18708",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-22313"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129294"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-18708"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011967"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1339"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18708"
      }
    ]
  },
  "id": "VAR-201810-0245",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-22313"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129294"
      }
    ],
    "trust": 1.4236169144444446
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-22313"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:38:16.715000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      },
      {
        "title": "",
        "trust": 0.1,
        "url": "https://github.com/saber0x0/iot_sec_learn "
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2018-18708"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011967"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-129294"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011967"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18708"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.2,
        "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/tenda.md"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18708"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18708"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/119.html"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/saber0x0/iot_sec_learn"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-22313"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129294"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-18708"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011967"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1339"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18708"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-22313"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129294"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-18708"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011967"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1339"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18708"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-11-01T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-22313"
      },
      {
        "date": "2018-10-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129294"
      },
      {
        "date": "2018-10-29T00:00:00",
        "db": "VULMON",
        "id": "CVE-2018-18708"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011967"
      },
      {
        "date": "2018-10-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1339"
      },
      {
        "date": "2018-10-29T12:29:05.617000",
        "db": "NVD",
        "id": "CVE-2018-18708"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-11-01T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-22313"
      },
      {
        "date": "2018-12-14T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129294"
      },
      {
        "date": "2018-12-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2018-18708"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011967"
      },
      {
        "date": "2018-10-31T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1339"
      },
      {
        "date": "2024-11-21T03:56:25.030000",
        "db": "NVD",
        "id": "CVE-2018-18708"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1339"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Product buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011967"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer overflow",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1339"
      }
    ],
    "trust": 0.6
  }
}

var-202203-1731
Vulnerability from variot

Tenda AC9 v15.03.2.21_cn was discovered to contain a stack overflow via the time parameter in the PowerSaveSet function. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.

A buffer overflow vulnerability exists in Tenda AC9 v15.03.2.21_cn. The vulnerability arises from the fact that when the time parameter in the PowerSaveSet function performs an operation on memory, the data boundary is not properly verified. An attacker can exploit this vulnerability to cause a heap buffer overflow and possibly execute arbitrary code

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202203-1731",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.2.21_cn"
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac9  firmware  15.03.2.21 cn"
      },
      {
        "model": "ac9 v15.03.2.21 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26240"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-007443"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26278"
      }
    ]
  },
  "cve": "CVE-2022-26278",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-26278",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-26240",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-26278",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-26278",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-26278",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-26278",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-26240",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202203-2355",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26240"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-007443"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-2355"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26278"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 v15.03.2.21_cn was discovered to contain a stack overflow via the time parameter in the PowerSaveSet function. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\r\n\r\nA buffer overflow vulnerability exists in Tenda AC9 v15.03.2.21_cn. The vulnerability arises from the fact that when the time parameter in the PowerSaveSet function performs an operation on memory, the data boundary is not properly verified. An attacker can exploit this vulnerability to cause a heap buffer overflow and possibly execute arbitrary code",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-26278"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-007443"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-26240"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-26278",
        "trust": 3.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-007443",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-26240",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-2355",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26240"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-007443"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-2355"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26278"
      }
    ]
  },
  "id": "VAR-202203-1731",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26240"
      }
    ],
    "trust": 1.319222275
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26240"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:04:56.356000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-007443"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26278"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.0,
        "url": "https://github.com/pllrry/tenda-ac9-v15.03.2.21_cn-command-execution-vulnerability/tree/main/tenda-ac9"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-26278"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-26278/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26240"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-007443"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-2355"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26278"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26240"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-007443"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-2355"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26278"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-06T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-26240"
      },
      {
        "date": "2023-07-14T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-007443"
      },
      {
        "date": "2022-03-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-2355"
      },
      {
        "date": "2022-03-28T21:15:08.773000",
        "db": "NVD",
        "id": "CVE-2022-26278"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-06T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-26240"
      },
      {
        "date": "2023-07-14T08:37:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-007443"
      },
      {
        "date": "2022-04-06T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-2355"
      },
      {
        "date": "2024-11-21T06:53:41.157000",
        "db": "NVD",
        "id": "CVE-2022-26278"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-2355"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-007443"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-2355"
      }
    ],
    "trust": 0.6
  }
}

var-201810-0275
Vulnerability from variot

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router's web server -- httpd. While processing the 'mac' parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow. plural Tenda The product contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0275",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.05.19_cn"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac7 v15.03.06.44 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10 v15.03.06.23 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac15 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01886"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011969"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1356"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18729"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac10_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac7_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011969"
      }
    ]
  },
  "cve": "CVE-2018-18729",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-18729",
            "impactScore": 8.5,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-01886",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-129317",
            "impactScore": 8.5,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-18729",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-18729",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-18729",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-01886",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201810-1356",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-129317",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01886"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129317"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011969"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1356"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18729"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027mac\u0027 parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow. plural Tenda The product contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-18729"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011969"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-01886"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129317"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-18729",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011969",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1356",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-01886",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-129317",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01886"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129317"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011969"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1356"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18729"
      }
    ]
  },
  "id": "VAR-201810-0275",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01886"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129317"
      }
    ],
    "trust": 1.4236169144444446
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01886"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:58:50.557000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011969"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-119",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-129317"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011969"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18729"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://github.com/zillr0/routers/blob/master/tenda/heapoverflow1.md"
      },
      {
        "trust": 1.4,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18729"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18729"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01886"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129317"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011969"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1356"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18729"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01886"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129317"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011969"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1356"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18729"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-01886"
      },
      {
        "date": "2018-10-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129317"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011969"
      },
      {
        "date": "2018-10-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1356"
      },
      {
        "date": "2018-10-29T12:29:07.617000",
        "db": "NVD",
        "id": "CVE-2018-18729"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-01886"
      },
      {
        "date": "2019-10-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129317"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011969"
      },
      {
        "date": "2019-10-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1356"
      },
      {
        "date": "2024-11-21T03:56:28.197000",
        "db": "NVD",
        "id": "CVE-2018-18729"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1356"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Product buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011969"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1356"
      }
    ],
    "trust": 0.6
  }
}

var-202308-3852
Vulnerability from variot

Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function. AC7 firmware, f1203 firmware, fh1205 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202308-3852",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac5",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.28"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.42_multi"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.44"
      },
      {
        "model": "fh1205",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "2.0.0.7\\(775\\)"
      },
      {
        "model": "f1203",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "2.0.1.6"
      },
      {
        "model": "f1203",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac5",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac7",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "fh1205",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021095"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38930"
      }
    ]
  },
  "cve": "CVE-2023-38930",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-38930",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-38930",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-38930",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-38930",
            "trust": 0.8,
            "value": "Critical"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021095"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38930"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function. AC7 firmware, f1203 firmware, fh1205 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-38930"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021095"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-38930",
        "trust": 2.6
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021095",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021095"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38930"
      }
    ]
  },
  "id": "VAR-202308-3852",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.29616356499999996
  },
  "last_update_date": "2024-08-14T15:00:06.598000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021095"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38930"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/addwifimacfilter/readme.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-38930"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021095"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38930"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021095"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38930"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-01-18T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-021095"
      },
      {
        "date": "2023-08-07T19:15:10.907000",
        "db": "NVD",
        "id": "CVE-2023-38930"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-01-18T06:42:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-021095"
      },
      {
        "date": "2023-08-09T18:05:36.363000",
        "db": "NVD",
        "id": "CVE-2023-38930"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021095"
      }
    ],
    "trust": 0.8
  }
}

var-202311-1968
Vulnerability from variot

Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202311-1968",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac19",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac6",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)"
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-38823"
      }
    ]
  },
  "cve": "CVE-2023-38823",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-38823",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-38823",
            "trust": 1.0,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-38823"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-38823"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-38823"
      }
    ],
    "trust": 0.99
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-38823",
        "trust": 1.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-38823",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-38823"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38823"
      }
    ]
  },
  "id": "VAR-202311-1968",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.41984727499999996
  },
  "last_update_date": "2024-08-14T15:36:40.786000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-38823"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.0,
        "url": "https://github.com/johnathanhuutri/cve_report/blob/master/cve-2023-38823/readme.md"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/nhtri2003gmail/cve_report/blob/master/cve-2023-38823.md"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-38823"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38823"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULMON",
        "id": "CVE-2023-38823"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38823"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-11-20T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-38823"
      },
      {
        "date": "2023-11-20T20:15:07.357000",
        "db": "NVD",
        "id": "CVE-2023-38823"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-11-21T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-38823"
      },
      {
        "date": "2024-07-29T22:15:03.200000",
        "db": "NVD",
        "id": "CVE-2023-38823"
      }
    ]
  }
}

var-201711-0574
Vulnerability from variot

Directory Traversal vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318)cn devices allows remote unauthenticated attackers to read arbitrary files via a cgi-bin/luci/request?op=1&path= URI that uses directory traversal sequences after a /usb/ substring. Shenzhen Tenda Ac9 , Ac15 ,and Ac18 The device contains a path traversal vulnerability.Information may be obtained. ShenzhenTendaAc9 and other are the wireless router products of Tenda. App_data_center is one of the application data centers. A directory traversal vulnerability exists in app_data_center in several ShenzhenTenda products. A remote attacker can exploit this vulnerability to read arbitrary files. The following products and versions are affected: Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01 Version, Ac9 ac9_kf_V15.03.05.19(6318)cn Version, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01 Version, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01 Version , Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01 version, Ac18 ac18_kf_V15.03.05.19(6318)_cn version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201711-0574",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "us_ac15v1.0br_v15.03.05.18_multi_td01"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "us_ac15v1.0br_v15.03.05.19_multi_td01"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "us_ac18v1.0br_v15.03.05.05_multi_td01"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "us_ac9v1.0br_v15.03.05.14_multi_td01"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "ac9_kf_v15.03.05.19\\(6318_\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "ac18_kf_v15.03.05.19\\(6318_\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18_kf_v15.03.05.19(6318_)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac9_kf_v15.03.05.19(6318_)_cn"
      },
      {
        "model": "tenda technology co.,ltd. ac9 us_ac9v1.0br_v15.03.05.14_multi_td01",
        "scope": null,
        "trust": 0.6,
        "vendor": "",
        "version": null
      },
      {
        "model": "tenda technology co.,ltd. ac9 ac9_kf_v15.03.05.19 _cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "",
        "version": null
      },
      {
        "model": "tenda technology co.,ltd. ac15 us_ac15v1.0br_v15.03.05.18_multi_td01",
        "scope": null,
        "trust": 0.6,
        "vendor": "",
        "version": null
      },
      {
        "model": "tenda technology co.,ltd. ac15 us_ac15v1.0br_v15.03.05.19_multi_td01",
        "scope": null,
        "trust": 0.6,
        "vendor": "",
        "version": null
      },
      {
        "model": "tenda technology co.,ltd. ac18 us_ac18v1.0br_v15.03.05.05_multi_td01",
        "scope": null,
        "trust": 0.6,
        "vendor": "",
        "version": null
      },
      {
        "model": "tenda technology co.,ltd. ac18 ac18 ac18_kf_v15.03.05.19 _cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-35381"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010756"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1055"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16936"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010756"
      }
    ]
  },
  "cve": "CVE-2017-16936",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 3.3,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.5,
            "id": "CVE-2017-16936",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "LOW",
            "trust": 1.8,
            "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2017-35381",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 3.3,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.5,
            "id": "VHN-107908",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "LOW",
            "trust": 0.1,
            "vectorString": "AV:A/AC:L/AU:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2017-16936",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2017-16936",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2017-16936",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2017-35381",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201711-1055",
            "trust": 0.6,
            "value": "LOW"
          },
          {
            "author": "VULHUB",
            "id": "VHN-107908",
            "trust": 0.1,
            "value": "LOW"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-35381"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107908"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010756"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1055"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16936"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Directory Traversal vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to read arbitrary files via a cgi-bin/luci/request?op=1\u0026path= URI that uses directory traversal sequences after a /usb/ substring. Shenzhen Tenda Ac9 , Ac15 ,and Ac18 The device contains a path traversal vulnerability.Information may be obtained. ShenzhenTendaAc9 and other are the wireless router products of Tenda. App_data_center is one of the application data centers. A directory traversal vulnerability exists in app_data_center in several ShenzhenTenda products. A remote attacker can exploit this vulnerability to read arbitrary files. The following products and versions are affected: Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01 Version, Ac9 ac9_kf_V15.03.05.19(6318_)_cn Version, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01 Version, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01 Version , Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01 version, Ac18 ac18_kf_V15.03.05.19(6318_)_cn version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-16936"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010756"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-35381"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107908"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2017-16936",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010756",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1055",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-35381",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-107908",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-35381"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107908"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010756"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1055"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16936"
      }
    ]
  },
  "id": "VAR-201711-0574",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-35381"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107908"
      }
    ],
    "trust": 1.1153522033333332
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-35381"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:12:47.863000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "http://tendacn.com/en/default.html"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010756"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-22",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-107908"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010756"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16936"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://github.com/iolop/poc/tree/master/router/tenda"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-16936"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-16936"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-35381"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107908"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010756"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1055"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16936"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-35381"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107908"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010756"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1055"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16936"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-11-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-35381"
      },
      {
        "date": "2017-11-24T00:00:00",
        "db": "VULHUB",
        "id": "VHN-107908"
      },
      {
        "date": "2017-12-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-010756"
      },
      {
        "date": "2017-11-27T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201711-1055"
      },
      {
        "date": "2017-11-24T07:29:00.350000",
        "db": "NVD",
        "id": "CVE-2017-16936"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-11-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-35381"
      },
      {
        "date": "2017-12-12T00:00:00",
        "db": "VULHUB",
        "id": "VHN-107908"
      },
      {
        "date": "2017-12-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-010756"
      },
      {
        "date": "2017-11-27T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201711-1055"
      },
      {
        "date": "2024-11-21T03:17:16.710000",
        "db": "NVD",
        "id": "CVE-2017-16936"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "specific network environment",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1055"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Shenzhen Tenda Path traversal vulnerability in devices",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010756"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "path traversal",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1055"
      }
    ],
    "trust": 0.6
  }
}

var-202205-0507
Vulnerability from variot

There is a stack overflow vulnerability in the goform/fast_setting_wifi_set function in the httpd service of Tenda ac9 15.03.2.21_cn router. An attacker can obtain a stable shell through a carefully constructed payload. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability stems from the fact that the goform/fast_setting_wifi_set function in the httpd service does not properly verify the data boundary when performing operations on memory

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202205-0507",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.2.21_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac9  firmware  15.03.2.21 cn"
      },
      {
        "model": "ac9 v15.03.2.21 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-38540"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008894"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-28560"
      }
    ]
  },
  "cve": "CVE-2022-28560",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-28560",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-38540",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-28560",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-28560",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-28560",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-28560",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-38540",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202205-1958",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULMON",
            "id": "CVE-2022-28560",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-38540"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-28560"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008894"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-1958"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-28560"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "There is a stack overflow vulnerability in the goform/fast_setting_wifi_set function in the httpd service of Tenda ac9 15.03.2.21_cn router. An attacker can obtain a stable shell through a carefully constructed payload. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability stems from the fact that the goform/fast_setting_wifi_set function in the httpd service does not properly verify the data boundary when performing operations on memory",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-28560"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008894"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-38540"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-28560"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-28560",
        "trust": 3.9
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008894",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-38540",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-1958",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-28560",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-38540"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-28560"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008894"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-1958"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-28560"
      }
    ]
  },
  "id": "VAR-202205-0507",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-38540"
      }
    ],
    "trust": 1.319222275
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-38540"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:24:50.807000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC9 Stack Overflow Vulnerability (CNVD-2022-38540)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/333436"
      },
      {
        "title": "Tenda AC9 Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=192390"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-38540"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-1958"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008894"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-28560"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://github.com/iot-firmeware/-router-vulnerability/tree/main/tenda%20ac9"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-28560"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-28560/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/787.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-38540"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-28560"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008894"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-1958"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-28560"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-38540"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-28560"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008894"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-1958"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-28560"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-05-20T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-38540"
      },
      {
        "date": "2022-05-03T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-28560"
      },
      {
        "date": "2023-08-01T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-008894"
      },
      {
        "date": "2022-05-03T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202205-1958"
      },
      {
        "date": "2022-05-03T16:15:19.130000",
        "db": "NVD",
        "id": "CVE-2022-28560"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-05-20T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-38540"
      },
      {
        "date": "2022-05-11T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-28560"
      },
      {
        "date": "2023-08-01T08:31:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-008894"
      },
      {
        "date": "2022-05-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202205-1958"
      },
      {
        "date": "2024-11-21T06:57:30.927000",
        "db": "NVD",
        "id": "CVE-2022-28560"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-1958"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008894"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-1958"
      }
    ],
    "trust": 0.6
  }
}

var-202005-0455
Vulnerability from variot

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/openSchedWifi schedStartTime and schedEndTime parameters for a POST request, a value is directly used in a strcpy to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202005-0455",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.06.42_multi"
      },
      {
        "model": "ac6",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19_multi_td01"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19_multi_td01"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "v1.0 15.03.05.19_multi_td01"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318_)_cn"
      },
      {
        "model": "ac6",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "v1.0 15.03.05.19_multi_td01"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "v1.0 15.03.05.19(6318)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "v3.0 15.03.06.42_multi"
      },
      {
        "model": "ac6 v15.03.05.19 multi td01",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0v15.03.05.19(6318)"
      },
      {
        "model": "ac9 v15.03.06.42 multi",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v3.0"
      },
      {
        "model": "ac15 v15.03.05.19 multi td01",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19(6318)"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31386"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005757"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13389"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac6_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005757"
      }
    ]
  },
  "cve": "CVE-2020-13389",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2020-13389",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.1,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 7.5,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-005757",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2020-31386",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2020-13389",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-005757",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-13389",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "JVNDB-2020-005757",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2020-31386",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202005-1139",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULMON",
            "id": "CVE-2020-13389",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31386"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13389"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005757"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1139"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13389"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the /goform/openSchedWifi schedStartTime and schedEndTime parameters for a POST request, a value is directly used in a strcpy to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-13389"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005757"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-31386"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13389"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-13389",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005757",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-31386",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1139",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13389",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31386"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13389"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005757"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1139"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13389"
      }
    ]
  },
  "id": "VAR-202005-0455",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31386"
      }
    ],
    "trust": 1.3076761016666667
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31386"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:48:00.116000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005757"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005757"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13389"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://joel-malwarebenchmark.github.io/blog/2020/04/28/cve-2020-13389-tenda-vulnerability/"
      },
      {
        "trust": 2.0,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-13389"
      },
      {
        "trust": 1.7,
        "url": "https://joel-malwarebenchmark.github.io"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-13389"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/120.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31386"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13389"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005757"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1139"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13389"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31386"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13389"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005757"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1139"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13389"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-31386"
      },
      {
        "date": "2020-05-22T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-13389"
      },
      {
        "date": "2020-06-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-005757"
      },
      {
        "date": "2020-05-22T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-1139"
      },
      {
        "date": "2020-05-22T17:15:11.033000",
        "db": "NVD",
        "id": "CVE-2020-13389"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-31386"
      },
      {
        "date": "2020-05-27T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-13389"
      },
      {
        "date": "2020-06-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-005757"
      },
      {
        "date": "2020-05-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-1139"
      },
      {
        "date": "2024-11-21T05:01:09.660000",
        "db": "NVD",
        "id": "CVE-2020-13389"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1139"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Classic buffer overflow vulnerability in device",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005757"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1139"
      }
    ],
    "trust": 0.6
  }
}

var-202110-1080
Vulnerability from variot

Buffer Overflow vulnerability in Tenda AC9 V1.0 through V15.03.05.19(6318), and AC9 V3.0 V15.03.06.42_multi, allows attackers to execute arbitrary code via the index parameter. Tenda AC9 Exists in a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC9 is a wireless router from Tenda in China

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202110-1080",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.06.42_multi"
      },
      {
        "model": "ac9",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac9  firmware"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": "gte",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0,\u003c=v15.03.05.19(6318)"
      },
      {
        "model": "ac9 \u003e=v3.0,\u003c=v15.03.06.42 multi",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-84225"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014384"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-31627"
      }
    ]
  },
  "cve": "CVE-2021-31627",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.5,
            "id": "CVE-2021-31627",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.9,
            "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.5,
            "id": "CNVD-2021-84225",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2021-31627",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Adjacent Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2021-31627",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2021-31627",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2021-31627",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-84225",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202110-2209",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2021-31627",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-84225"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-31627"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014384"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-2209"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-31627"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Buffer Overflow vulnerability in Tenda AC9 V1.0 through V15.03.05.19(6318), and AC9 V3.0 V15.03.06.42_multi, allows attackers to execute arbitrary code via the index parameter. Tenda AC9 Exists in a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC9 is a wireless router from Tenda in China",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-31627"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014384"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-84225"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-31627"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-31627",
        "trust": 3.9
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014384",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-84225",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-2209",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-31627",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-84225"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-31627"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014384"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-2209"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-31627"
      }
    ]
  },
  "id": "VAR-202110-1080",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-84225"
      }
    ],
    "trust": 1.319222275
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-84225"
      }
    ]
  },
  "last_update_date": "2024-08-14T15:01:18.002000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top\u00a0Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/default.html"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014384"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      },
      {
        "problemtype": "Classic buffer overflow (CWE-120) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014384"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-31627"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://github.com/lyc-heng/routers/blob/main/routers/stack3.md"
      },
      {
        "trust": 2.3,
        "url": "http://tenda.com"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-31627"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/120.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-84225"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-31627"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014384"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-2209"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-31627"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-84225"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-31627"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014384"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-2209"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-31627"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-11-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-84225"
      },
      {
        "date": "2021-10-29T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-31627"
      },
      {
        "date": "2022-10-17T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-014384"
      },
      {
        "date": "2021-10-29T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202110-2209"
      },
      {
        "date": "2021-10-29T11:15:08.433000",
        "db": "NVD",
        "id": "CVE-2021-31627"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-11-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-84225"
      },
      {
        "date": "2021-11-03T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-31627"
      },
      {
        "date": "2022-10-17T08:55:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-014384"
      },
      {
        "date": "2021-11-04T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202110-2209"
      },
      {
        "date": "2021-11-03T12:18:22.917000",
        "db": "NVD",
        "id": "CVE-2021-31627"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote or local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-2209"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0AC9\u00a0 Classic buffer overflow vulnerability in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014384"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-2209"
      }
    ],
    "trust": 0.6
  }
}

var-202208-2227
Vulnerability from variot

Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the deviceList parameter at /goform/setMacFilterCfg. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202208-2227",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac9  firmware  15.03.05.19"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015960"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36569"
      }
    ]
  },
  "cve": "CVE-2022-36569",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2022-36569",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-36569",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-36569",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-36569",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202208-4524",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015960"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4524"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36569"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the deviceList parameter at /goform/setMacFilterCfg. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-36569"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015960"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-36569",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015960",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4524",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015960"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4524"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36569"
      }
    ]
  },
  "id": "VAR-202208-2227",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.43844455
  },
  "last_update_date": "2024-08-14T13:21:44.155000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015960"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36569"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/cyberunicorniot/iotvuln/blob/main/tenda_ac9/4/tenda_ac9_setmacfiltercfg.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-36569"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-36569/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015960"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4524"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36569"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015960"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4524"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36569"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-09-29T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-015960"
      },
      {
        "date": "2022-08-31T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202208-4524"
      },
      {
        "date": "2022-08-31T20:15:08.927000",
        "db": "NVD",
        "id": "CVE-2022-36569"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-09-29T08:06:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-015960"
      },
      {
        "date": "2022-09-05T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202208-4524"
      },
      {
        "date": "2022-09-02T22:04:37.257000",
        "db": "NVD",
        "id": "CVE-2022-36569"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4524"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015960"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4524"
      }
    ],
    "trust": 0.6
  }
}

var-201810-0243
Vulnerability from variot

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromDhcpListClient" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. The AC series is a router product from Tenda. httpd is one of the HTTP server components. The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0243",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.05.19_cn"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac7 v15.03.06.44 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10 v15.03.06.23 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac15 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09140"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011965"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1337"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18706"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac10_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac7_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011965"
      }
    ]
  },
  "cve": "CVE-2018-18706",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-18706",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-09140",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-129292",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-18706",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-18706",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-18706",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-09140",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201810-1337",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-129292",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09140"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129292"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011965"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1337"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18706"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromDhcpListClient\" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. The AC series is a router product from Tenda. httpd is one of the HTTP server components. The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-18706"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011965"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-09140"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129292"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-18706",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011965",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1337",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-09140",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-129292",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09140"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129292"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011965"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1337"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18706"
      }
    ]
  },
  "id": "VAR-201810-0243",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09140"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129292"
      }
    ],
    "trust": 1.4236169144444446
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09140"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:12:19.756000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011965"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-129292"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011965"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18706"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/tenda.md"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18706"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18706"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09140"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129292"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011965"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1337"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18706"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09140"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129292"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011965"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1337"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18706"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-04-04T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-09140"
      },
      {
        "date": "2018-10-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129292"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011965"
      },
      {
        "date": "2018-10-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1337"
      },
      {
        "date": "2018-10-29T12:29:05.400000",
        "db": "NVD",
        "id": "CVE-2018-18706"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-04-04T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-09140"
      },
      {
        "date": "2018-12-14T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129292"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011965"
      },
      {
        "date": "2018-10-31T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1337"
      },
      {
        "date": "2024-11-21T03:56:24.723000",
        "db": "NVD",
        "id": "CVE-2018-18706"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1337"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Product buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011965"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer overflow",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1337"
      }
    ],
    "trust": 0.6
  }
}

var-202110-1440
Vulnerability from variot

Buffer Overflow vulnerability in Tenda AC9 V1.0 through V15.03.05.19(6318), and AC9 V3.0 V15.03.06.42_multi, allows attackers to execute arbitrary code via the urls parameter. Tenda AC9 Exists in a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC9 is a wireless router from the Chinese company Tenda

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202110-1440",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.06.42_multi"
      },
      {
        "model": "ac9",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac9  firmware"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": "gte",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0,\u003c=v15.03.05.19(6318)"
      },
      {
        "model": "ac9 \u003e=v3.0,\u003c=v15.03.06.42 multi",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-42149"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014386"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-31624"
      }
    ]
  },
  "cve": "CVE-2021-31624",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.5,
            "id": "CVE-2021-31624",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.5,
            "id": "CNVD-2022-42149",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2021-31624",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Adjacent Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2021-31624",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2021-31624",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2021-31624",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-42149",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202110-2208",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-42149"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014386"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-2208"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-31624"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Buffer Overflow vulnerability in Tenda AC9 V1.0 through V15.03.05.19(6318), and AC9 V3.0 V15.03.06.42_multi, allows attackers to execute arbitrary code via the urls parameter. Tenda AC9 Exists in a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC9 is a wireless router from the Chinese company Tenda",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-31624"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014386"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-42149"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-31624",
        "trust": 3.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014386",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-42149",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-2208",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-42149"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014386"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-2208"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-31624"
      }
    ]
  },
  "id": "VAR-202110-1440",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-42149"
      }
    ],
    "trust": 1.319222275
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-42149"
      }
    ]
  },
  "last_update_date": "2024-08-14T14:03:01.827000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top\u00a0Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/default.html"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014386"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      },
      {
        "problemtype": "Classic buffer overflow (CWE-120) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014386"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-31624"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.0,
        "url": "https://github.com/lyc-heng/routers/blob/main/routers/stack2.md"
      },
      {
        "trust": 2.2,
        "url": "http://tenda.com"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-31624"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-42149"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014386"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-2208"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-31624"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-42149"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014386"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-2208"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-31624"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-05-31T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-42149"
      },
      {
        "date": "2022-10-17T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-014386"
      },
      {
        "date": "2021-10-29T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202110-2208"
      },
      {
        "date": "2021-10-29T11:15:08.383000",
        "db": "NVD",
        "id": "CVE-2021-31624"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-05-31T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-42149"
      },
      {
        "date": "2022-10-17T09:25:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-014386"
      },
      {
        "date": "2021-11-03T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202110-2208"
      },
      {
        "date": "2021-11-02T17:11:52.207000",
        "db": "NVD",
        "id": "CVE-2021-31624"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote or local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-2208"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0AC9\u00a0 Classic buffer overflow vulnerability in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014386"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-2208"
      }
    ],
    "trust": 0.6
  }
}

var-202105-1648
Vulnerability from variot

AC9 is a 1200M 11AC wireless router with Gigabit Ethernet port launched by Shenzhen Jixiang Tengda Technology Co., Ltd. in 2016.

Tenda AC9 has a denial of service vulnerability, which can be exploited by attackers to cause the program to crash.

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202105-1648",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0v15.03.05.19(6318)"
      },
      {
        "model": "ac9 v15.03.06.42 multi",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v3.0"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-26080"
      }
    ]
  },
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "CNVD-2021-26080",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "CNVD",
            "id": "CNVD-2021-26080",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-26080"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "AC9 is a 1200M 11AC wireless router with Gigabit Ethernet port launched by Shenzhen Jixiang Tengda Technology Co., Ltd. in 2016.\n\r\n\r\nTenda AC9 has a denial of service vulnerability, which can be exploited by attackers to cause the program to crash.",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-26080"
      }
    ],
    "trust": 0.6
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-26080",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-26080"
      }
    ]
  },
  "id": "VAR-202105-1648",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-26080"
      }
    ],
    "trust": 1.3881356
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-26080"
      }
    ]
  },
  "last_update_date": "2022-05-04T10:25:21.488000Z",
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-26080"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-05-10T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-26080"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-04-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-26080"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 has a denial of service vulnerability (CNVD-2021-26080)",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-26080"
      }
    ],
    "trust": 0.6
  }
}

var-201711-0630
Vulnerability from variot

Command Injection vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318)cn devices allows remote unauthenticated attackers to execute arbitrary OS commands via a crafted cgi-bin/luci/usbeject?dev_name= GET request from the LAN. This occurs because the "sub_A6E8 usbeject_process_entry" function executes a system function with untrusted input. Shenzhen Tenda Ac9 , Ac15 ,and Ac18 The device contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. ShenzhenTendaAc9 and other are the wireless router products of Tenda. App_data_center is one of the application data centers. There is a command injection vulnerability in app_data_center in several ShenzhenTenda products. The following versions are affected: Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01 Version, Ac9 ac9_kf_V15.03.05.19(6318)cn Version, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01 Version, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01 Version, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01 version, Ac18 ac18_kf_V15.03.05.19(6318)_cn devices version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201711-0630",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "us_ac15v1.0br_v15.03.05.18_multi_td01"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "us_ac15v1.0br_v15.03.05.19_multi_td01"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "us_ac18v1.0br_v15.03.05.05_multi_td01"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "us_ac9v1.0br_v15.03.05.14_multi_td01"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "ac9_kf_v15.03.05.19\\(6318_\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "ac18_kf_v15.03.05.19\\(6318_\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac18_kf_v15.03.05.19(6318_)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac9_kf_v15.03.05.19(6318_)_cn"
      },
      {
        "model": "tenda technology co.,ltd. w15e devices",
        "scope": null,
        "trust": 0.6,
        "vendor": "",
        "version": null
      },
      {
        "model": "tenda technology co.,ltd. ac9 us_ac9v1.0br_v15.03.05.14_multi_td01",
        "scope": null,
        "trust": 0.6,
        "vendor": "",
        "version": null
      },
      {
        "model": "tenda technology co.,ltd. ac9 ac9_kf_v15.03.05.19 _cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "",
        "version": null
      },
      {
        "model": "tenda technology co.,ltd. ac9 ac15 us_ac15v1.0br_v15.03.05.18_multi_td01",
        "scope": null,
        "trust": 0.6,
        "vendor": "",
        "version": null
      },
      {
        "model": "tenda technology co.,ltd. ac9 ac15 us_ac15v1.0br_v15.03.05.19_multi_td01",
        "scope": null,
        "trust": 0.6,
        "vendor": "",
        "version": null
      },
      {
        "model": "tenda technology co.,ltd. ac9 ac18 us_ac18v1.0br_v15.03.05.05_multi_td01",
        "scope": null,
        "trust": 0.6,
        "vendor": "",
        "version": null
      },
      {
        "model": "tenda technology co.,ltd. ac9 ac18 ac18_kf_v15.03.05.19 _cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-37811"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010774"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-888"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16923"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010774"
      }
    ]
  },
  "cve": "CVE-2017-16923",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 8.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 6.5,
            "id": "CVE-2017-16923",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 8.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 6.5,
            "id": "CNVD-2017-37811",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 8.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 6.5,
            "id": "VHN-107894",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:A/AC:L/AU:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2017-16923",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2017-16923",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2017-16923",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2017-37811",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201711-888",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-107894",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-37811"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107894"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010774"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-888"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16923"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Command Injection vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to execute arbitrary OS commands via a crafted cgi-bin/luci/usbeject?dev_name= GET request from the LAN. This occurs because the \"sub_A6E8 usbeject_process_entry\" function executes a system function with untrusted input. Shenzhen Tenda Ac9 , Ac15 ,and Ac18 The device contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. ShenzhenTendaAc9 and other are the wireless router products of Tenda. App_data_center is one of the application data centers. There is a command injection vulnerability in app_data_center in several ShenzhenTenda products. The following versions are affected: Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01 Version, Ac9 ac9_kf_V15.03.05.19(6318_)_cn Version, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01 Version, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01 Version, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01 version, Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-16923"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010774"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-37811"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107894"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2017-16923",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010774",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-888",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-37811",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-107894",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-37811"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107894"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010774"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-888"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16923"
      }
    ]
  },
  "id": "VAR-201711-0630",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-37811"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107894"
      }
    ],
    "trust": 1.1153522033333332
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-37811"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:45:33.771000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "http://tendacn.com/en/default.html"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010774"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-78",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-77",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-107894"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010774"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16923"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://github.com/iolop/poc/tree/master/router/tenda"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-16923"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-16923"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-37811"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107894"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010774"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-888"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16923"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-37811"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107894"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010774"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-888"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16923"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-12-21T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-37811"
      },
      {
        "date": "2017-11-21T00:00:00",
        "db": "VULHUB",
        "id": "VHN-107894"
      },
      {
        "date": "2017-12-25T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-010774"
      },
      {
        "date": "2017-11-24T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201711-888"
      },
      {
        "date": "2017-11-21T14:29:00.260000",
        "db": "NVD",
        "id": "CVE-2017-16923"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-12-21T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-37811"
      },
      {
        "date": "2019-10-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-107894"
      },
      {
        "date": "2017-12-25T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-010774"
      },
      {
        "date": "2019-10-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201711-888"
      },
      {
        "date": "2024-11-21T03:17:14.913000",
        "db": "NVD",
        "id": "CVE-2017-16923"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote or local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-888"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Shenzhen Tenda Command injection vulnerability in devices",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-010774"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "operating system commend injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-888"
      }
    ],
    "trust": 0.6
  }
}

var-201810-0274
Vulnerability from variot

An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. They allow remote code execution via shell metacharacters in the usbName field to the __fastcall function with a POST request. plural Tenda The product contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. TendaAC9, AC15 and AC18 are all wireless router products from Tenda. Security flaws exist in Tenda AC9, AC15, and AC18. The following products and versions are affected: Tenda AC9 V15.03.05.19(6318)_CN version; AC15 V15.03.05.19_CN version; AC18 V15.03.05.19(6318)_CN version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0274",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.05.19_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac15 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01887"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1355"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18728"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011975"
      }
    ]
  },
  "cve": "CVE-2018-18728",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-18728",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-01887",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-129316",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-18728",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-18728",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-18728",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-01887",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201810-1355",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-129316",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01887"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129316"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1355"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18728"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. They allow remote code execution via shell metacharacters in the usbName field to the __fastcall function with a POST request. plural Tenda The product contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. TendaAC9, AC15 and AC18 are all wireless router products from Tenda. Security flaws exist in Tenda AC9, AC15, and AC18. The following products and versions are affected: Tenda AC9 V15.03.05.19(6318)_CN version; AC15 V15.03.05.19_CN version; AC18 V15.03.05.19(6318)_CN version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-18728"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011975"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-01887"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129316"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-18728",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011975",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1355",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-01887",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-129316",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01887"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129316"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1355"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18728"
      }
    ]
  },
  "id": "VAR-201810-0274",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01887"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129316"
      }
    ],
    "trust": 1.4076761016666666
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01887"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:51:59.280000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011975"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-78",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-77",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-129316"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011975"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18728"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://github.com/zillr0/routers/blob/master/tenda/rce1.md"
      },
      {
        "trust": 1.4,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18728"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18728"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01887"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129316"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1355"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18728"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01887"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129316"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1355"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18728"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-01887"
      },
      {
        "date": "2018-10-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129316"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011975"
      },
      {
        "date": "2018-10-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1355"
      },
      {
        "date": "2018-10-29T12:29:07.507000",
        "db": "NVD",
        "id": "CVE-2018-18728"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-01887"
      },
      {
        "date": "2019-10-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129316"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011975"
      },
      {
        "date": "2019-10-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1355"
      },
      {
        "date": "2024-11-21T03:56:28.030000",
        "db": "NVD",
        "id": "CVE-2018-18728"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1355"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Command injection vulnerability in the product",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011975"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "operating system commend injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1355"
      }
    ],
    "trust": 0.6
  }
}

var-202202-1589
Vulnerability from variot

Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function saveparentcontrolinfo. Tenda AC9 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202202-1589",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "v15.03.2.21_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac9  firmware  15.03.2.21_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006051"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25417"
      }
    ]
  },
  "cve": "CVE-2022-25417",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-25417",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-25417",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-25417",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-25417",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-25417",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202202-1828",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006051"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1828"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25417"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function saveparentcontrolinfo. Tenda AC9 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25417"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006051"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-25417",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006051",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1828",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006051"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1828"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25417"
      }
    ]
  },
  "id": "VAR-202202-1589",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.43844455
  },
  "last_update_date": "2024-11-23T22:15:55.792000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top\u00a0Page",
        "trust": 0.8,
        "url": "https://www.tendacn.com/default.html"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006051"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006051"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25417"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/ephaha/iot_vuln/tree/main/tenda/ac9/3"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-25417"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-25417/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006051"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1828"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25417"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006051"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1828"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25417"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-06-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-006051"
      },
      {
        "date": "2022-02-24T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202202-1828"
      },
      {
        "date": "2022-02-24T15:15:31.900000",
        "db": "NVD",
        "id": "CVE-2022-25417"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-06-26T08:44:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-006051"
      },
      {
        "date": "2022-03-10T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202202-1828"
      },
      {
        "date": "2024-11-21T06:52:09.623000",
        "db": "NVD",
        "id": "CVE-2022-25417"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1828"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0AC9\u00a0 Out-of-bounds write vulnerability in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006051"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1828"
      }
    ],
    "trust": 0.6
  }
}

var-201807-1285
Vulnerability from variot

Tenda AC7 through V15.03.06.44_CN, AC9 through V15.03.05.19(6318)_CN, and AC10 through V15.03.06.23_CN devices have a Stack-based Buffer Overflow via a long limitSpeed or limitSpeedup parameter to an unspecified /goform URI. Tenda AC7 , AC9 ,and AC10 Contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7, AC9 and AC10 are all wireless router products from Tenda. A buffer overflow vulnerability exists in TendaAC715.03.06.44_CN and previous versions, AC915.03.05.19 (6318)_CN and previous versions, and AC1015.03.06.23_CN and earlier. An attacker could exploit the vulnerability with a longer \342\200\230limitSpeed\342\200\231 or \342\200\230limitSpeedup\342\200\231 parameter to cause a denial of service

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201807-1285",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac7",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac10",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac9",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac15",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.05.19_cn"
      },
      {
        "model": "ac10",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac15",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac7",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac9",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac7 \u003c=15.03.06.44 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10 \u003c=15.03.06.23 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 \u003c=15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tendacn",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tendacn",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tendacn",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tendacn",
        "version": "15.03.05.19_cn"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-14983"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008461"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-1668"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14492"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tendacn:ac10_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac7_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008461"
      }
    ]
  },
  "cve": "CVE-2018-14492",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-14492",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2018-14983",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-124657",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-14492",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-14492",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-14492",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-14983",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201807-1668",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-124657",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-14983"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124657"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008461"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-1668"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14492"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC7 through V15.03.06.44_CN, AC9 through V15.03.05.19(6318)_CN, and AC10 through V15.03.06.23_CN devices have a Stack-based Buffer Overflow via a long limitSpeed or limitSpeedup parameter to an unspecified /goform URI. Tenda AC7 , AC9 ,and AC10 Contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7, AC9 and AC10 are all wireless router products from Tenda. A buffer overflow vulnerability exists in TendaAC715.03.06.44_CN and previous versions, AC915.03.05.19 (6318)_CN and previous versions, and AC1015.03.06.23_CN and earlier. An attacker could exploit the vulnerability with a longer \\342\\200\\230limitSpeed\\342\\200\\231 or \\342\\200\\230limitSpeedup\\342\\200\\231 parameter to cause a denial of service",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-14492"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008461"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-14983"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124657"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-14492",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008461",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-1668",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-14983",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-124657",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-14983"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124657"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008461"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-1668"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14492"
      }
    ]
  },
  "id": "VAR-201807-1285",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-14983"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124657"
      }
    ],
    "trust": 1.3446503185714285
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-14983"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:52:01.968000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008461"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-119",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-124657"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008461"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14492"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://github.com/zillr0/routers/blob/master/tendaoob1.md"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14492"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14492"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-14983"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124657"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008461"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-1668"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14492"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-14983"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124657"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008461"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-1668"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14492"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-08-10T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-14983"
      },
      {
        "date": "2018-07-21T00:00:00",
        "db": "VULHUB",
        "id": "VHN-124657"
      },
      {
        "date": "2018-10-18T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-008461"
      },
      {
        "date": "2018-07-21T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201807-1668"
      },
      {
        "date": "2018-07-21T12:29:00.333000",
        "db": "NVD",
        "id": "CVE-2018-14492"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-08-10T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-14983"
      },
      {
        "date": "2020-08-24T00:00:00",
        "db": "VULHUB",
        "id": "VHN-124657"
      },
      {
        "date": "2018-10-18T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-008461"
      },
      {
        "date": "2020-08-25T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201807-1668"
      },
      {
        "date": "2024-11-21T03:49:10.740000",
        "db": "NVD",
        "id": "CVE-2018-14492"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-1668"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Product buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008461"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-1668"
      }
    ],
    "trust": 0.6
  }
}

var-201810-0977
Vulnerability from variot

An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input. Tenda AC7 , AC9 ,and AC10 The firmware contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Tenda AC7, AC9 and AC10 are all wireless router products from China Tenda.

Tenda AC7, AC9 and AC10 have command injection vulnerabilities. The following products and versions are affected: Tenda AC7 (using firmware 15.03.06.44_CN and earlier); AC9 (using firmware 15.03.05.19(6318)_CN and earlier); AC10 (using firmware 15.03.06.23_CN and earlier)

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0977",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10",
        "scope": "lte",
        "trust": 1.8,
        "vendor": "tenda",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac7",
        "scope": "lte",
        "trust": 1.8,
        "vendor": "tenda",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac9",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac9",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac7 \u003c=15.03.06.44 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10 \u003c=15.03.06.23 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 \u003c=15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35174"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013995"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14558"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac10_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac7_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013995"
      }
    ]
  },
  "cve": "CVE-2018-14558",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-14558",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2020-35174",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "VHN-124729",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-14558",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-14558",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-14558",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2020-35174",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201810-1439",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-124729",
            "trust": 0.1,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2018-14558",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35174"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124729"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-14558"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013995"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1439"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14558"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the \"formsetUsbUnload\" function executes a dosystemCmd function with untrusted input. Tenda AC7 , AC9 ,and AC10 The firmware contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Tenda AC7, AC9 and AC10 are all wireless router products from China Tenda. \n\r\n\r\nTenda AC7, AC9 and AC10 have command injection vulnerabilities. The following products and versions are affected: Tenda AC7 (using firmware 15.03.06.44_CN and earlier); AC9 (using firmware 15.03.05.19(6318)_CN and earlier); AC10 (using firmware 15.03.06.23_CN and earlier)",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-14558"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013995"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-35174"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124729"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-14558"
      }
    ],
    "trust": 2.34
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-14558",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013995",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1439",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-35174",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-124729",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-14558",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35174"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124729"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-14558"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013995"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1439"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14558"
      }
    ]
  },
  "id": "VAR-201810-0977",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35174"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124729"
      }
    ],
    "trust": 1.440988034
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35174"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:41:39.731000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013995"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-78",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-77",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-124729"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013995"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14558"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.6,
        "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/tenda.md"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14558"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14558"
      },
      {
        "trust": 0.6,
        "url": "http://www.cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14558"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/78.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35174"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124729"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-14558"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013995"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1439"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14558"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35174"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124729"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-14558"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013995"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1439"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14558"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-30T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-35174"
      },
      {
        "date": "2018-10-30T00:00:00",
        "db": "VULHUB",
        "id": "VHN-124729"
      },
      {
        "date": "2018-10-30T00:00:00",
        "db": "VULMON",
        "id": "CVE-2018-14558"
      },
      {
        "date": "2019-03-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-013995"
      },
      {
        "date": "2018-10-31T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1439"
      },
      {
        "date": "2018-10-30T18:29:00.580000",
        "db": "NVD",
        "id": "CVE-2018-14558"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-30T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-35174"
      },
      {
        "date": "2019-10-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-124729"
      },
      {
        "date": "2019-10-03T00:00:00",
        "db": "VULMON",
        "id": "CVE-2018-14558"
      },
      {
        "date": "2019-03-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-013995"
      },
      {
        "date": "2019-10-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1439"
      },
      {
        "date": "2024-11-21T03:49:18.470000",
        "db": "NVD",
        "id": "CVE-2018-14558"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1439"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Command injection vulnerability in product firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013995"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "operating system commend injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1439"
      }
    ],
    "trust": 0.6
  }
}

var-202203-1212
Vulnerability from variot

Tenda AC9 v15.03.2.21 was discovered to contain multiple stack overflows via the NPTR, V12, V10 and V11 parameter in the Formsetqosband function. The Tenda AC9 is a wireless router from the Chinese company Tenda.

A stack overflow vulnerability exists in the Tenda AC9 Formsetqosband function, which can be exploited by an attacker to cause arbitrary command execution

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202203-1212",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.2.21"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.2.21"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24428"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25431"
      }
    ]
  },
  "cve": "CVE-2022-25431",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-25431",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-24428",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-25431",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-25431",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-24428",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202203-1856",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24428"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1856"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25431"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 v15.03.2.21 was discovered to contain multiple stack overflows via the NPTR, V12, V10 and V11 parameter in the Formsetqosband function. The Tenda AC9 is a wireless router from the Chinese company Tenda. \n\r\n\r\nA stack overflow vulnerability exists in the Tenda AC9 Formsetqosband function, which can be exploited by an attacker to cause arbitrary command execution",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25431"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-24428"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-25431",
        "trust": 2.2
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-24428",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1856",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24428"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1856"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25431"
      }
    ]
  },
  "id": "VAR-202203-1212",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24428"
      }
    ],
    "trust": 1.03844455
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24428"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:50:39.222000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC9 Formsetqosband Function Stack Overflow Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/328491"
      },
      {
        "title": "Tenda AC9 Fixes for command injection vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=186936"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24428"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1856"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25431"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://github.com/ephaha/iot_vuln/tree/main/tenda/ac9/4"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-25431"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-25431/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24428"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1856"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25431"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24428"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1856"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25431"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-02T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-24428"
      },
      {
        "date": "2022-03-18T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1856"
      },
      {
        "date": "2022-03-18T21:15:08.017000",
        "db": "NVD",
        "id": "CVE-2022-25431"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-03-31T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-24428"
      },
      {
        "date": "2022-03-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1856"
      },
      {
        "date": "2024-11-21T06:52:10.413000",
        "db": "NVD",
        "id": "CVE-2022-25431"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1856"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 Formsetqosband Function Stack Overflow Vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24428"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "command injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1856"
      }
    ],
    "trust": 0.6
  }
}

var-201803-2233
Vulnerability from variot

Stack-based Buffer Overflow in httpd on Tenda AC9 devices V15.03.05.14_EN allows remote attackers to cause a denial of service or possibly have unspecified other impact. Tenda AC9 The device contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. TendaAC9 is a wireless router product from Tenda. A stack buffer overflow vulnerability exists in httpd in TendaAC9. A remote attacker could exploit the vulnerability to cause a denial of service

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201803-2233",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tendacn",
        "version": "15.03.05.14_en"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.14_en"
      },
      {
        "model": "tenda technology co.,ltd. ac9 v15.03.05.14_en",
        "scope": null,
        "trust": 0.6,
        "vendor": "",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-04731"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-002524"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201803-040"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-7561"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-002524"
      }
    ]
  },
  "cve": "CVE-2018-7561",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-7561",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CNVD-2018-04731",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-137593",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-7561",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-7561",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-7561",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-04731",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201803-040",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-137593",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-04731"
      },
      {
        "db": "VULHUB",
        "id": "VHN-137593"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-002524"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201803-040"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-7561"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Stack-based Buffer Overflow in httpd on Tenda AC9 devices V15.03.05.14_EN allows remote attackers to cause a denial of service or possibly have unspecified other impact. Tenda AC9 The device contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. TendaAC9 is a wireless router product from Tenda. A stack buffer overflow vulnerability exists in httpd in TendaAC9. A remote attacker could exploit the vulnerability to cause a denial of service",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-7561"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-002524"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-04731"
      },
      {
        "db": "VULHUB",
        "id": "VHN-137593"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-7561",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-002524",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201803-040",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-04731",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-137593",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-04731"
      },
      {
        "db": "VULHUB",
        "id": "VHN-137593"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-002524"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201803-040"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-7561"
      }
    ]
  },
  "id": "VAR-201803-2233",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-04731"
      },
      {
        "db": "VULHUB",
        "id": "VHN-137593"
      }
    ],
    "trust": 1.13844455
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-04731"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:38:14.493000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "AC9    /    Router    /    AC1200 Smart Dual-Band Gigabit WiFi Router",
        "trust": 0.8,
        "url": "http://tendacn.com/en/product/AC9.html"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-002524"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-119",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-137593"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-002524"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-7561"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://github.com/vuldetailspublication/poc/tree/master/tenda/ac9"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-7561"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-7561"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-04731"
      },
      {
        "db": "VULHUB",
        "id": "VHN-137593"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-002524"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201803-040"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-7561"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-04731"
      },
      {
        "db": "VULHUB",
        "id": "VHN-137593"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-002524"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201803-040"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-7561"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-03-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-04731"
      },
      {
        "date": "2018-03-01T00:00:00",
        "db": "VULHUB",
        "id": "VHN-137593"
      },
      {
        "date": "2018-04-17T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-002524"
      },
      {
        "date": "2018-03-05T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201803-040"
      },
      {
        "date": "2018-03-01T15:29:00.213000",
        "db": "NVD",
        "id": "CVE-2018-7561"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-03-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-04731"
      },
      {
        "date": "2020-08-24T00:00:00",
        "db": "VULHUB",
        "id": "VHN-137593"
      },
      {
        "date": "2018-04-17T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-002524"
      },
      {
        "date": "2020-08-25T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201803-040"
      },
      {
        "date": "2024-11-21T04:12:22.127000",
        "db": "NVD",
        "id": "CVE-2018-7561"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201803-040"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 Device buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-002524"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201803-040"
      }
    ],
    "trust": 0.6
  }
}

var-202308-3841
Vulnerability from variot

Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware and AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202308-3841",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac5",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.28"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.42_multi"
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac5",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011498"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41563"
      }
    ]
  },
  "cve": "CVE-2023-41563",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-41563",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-41563",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-41563",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-41563",
            "trust": 0.8,
            "value": "Critical"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011498"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41563"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware and AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-41563"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011498"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-41563",
        "trust": 2.6
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011498",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011498"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41563"
      }
    ]
  },
  "id": "VAR-202308-3841",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.43844455
  },
  "last_update_date": "2024-08-14T14:48:56.348000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011498"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41563"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/peris-navince/founded-0-days/blob/main/getparentcontrolinfo/1.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-41563"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011498"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41563"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011498"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41563"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-12-13T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-011498"
      },
      {
        "date": "2023-08-30T13:15:15.043000",
        "db": "NVD",
        "id": "CVE-2023-41563"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-12-13T07:01:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-011498"
      },
      {
        "date": "2023-09-01T19:54:35.217000",
        "db": "NVD",
        "id": "CVE-2023-41563"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 firmware and \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011498"
      }
    ],
    "trust": 0.8
  }
}

var-202203-1209
Vulnerability from variot

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the schedendtime parameter in the openSchedWifi function. The Tenda AC9 is a wireless router from the Chinese company Tenda

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202203-1209",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.2.21"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.2.21"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24427"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25427"
      }
    ]
  },
  "cve": "CVE-2022-25427",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-25427",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-24427",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-25427",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-25427",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-24427",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202203-1861",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24427"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1861"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25427"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the schedendtime parameter in the openSchedWifi function. The Tenda AC9 is a wireless router from the Chinese company Tenda",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25427"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-24427"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-25427",
        "trust": 2.2
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-24427",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1861",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24427"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1861"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25427"
      }
    ]
  },
  "id": "VAR-202203-1209",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24427"
      }
    ],
    "trust": 1.03844455
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24427"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:10:52.294000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC9 openSchedWifi function stack overflow vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/328496"
      },
      {
        "title": "Tenda AC9 Fixes for command injection vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=186939"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24427"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1861"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25427"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://github.com/ephaha/iot_vuln/tree/main/tenda/ac9/2"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-25427"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-25427/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24427"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1861"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25427"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24427"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1861"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25427"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-02T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-24427"
      },
      {
        "date": "2022-03-18T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1861"
      },
      {
        "date": "2022-03-18T21:15:07.907000",
        "db": "NVD",
        "id": "CVE-2022-25427"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-03-31T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-24427"
      },
      {
        "date": "2022-03-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1861"
      },
      {
        "date": "2024-11-21T06:52:10.013000",
        "db": "NVD",
        "id": "CVE-2022-25427"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1861"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 openSchedWifi function stack overflow vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-24427"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "command injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1861"
      }
    ],
    "trust": 0.6
  }
}

var-202104-1991
Vulnerability from variot

AC9 is a 1200M 11AC wireless router with Gigabit Ethernet port launched by Shenzhen Jixiang Tengda Technology Co., Ltd. in 2016.

Tenda AC9 has a denial of service vulnerability, which can be exploited by an attacker to cause a denial of service attack.

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202104-1991",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0v15.03.05.19(6318)"
      },
      {
        "model": "ac9 v15.03.06.42 multi",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v3.0"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17400"
      }
    ]
  },
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "HIGH",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 4.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.5,
            "id": "CNVD-2021-17400",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:A/AC:H/Au:S/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "CNVD",
            "id": "CNVD-2021-17400",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17400"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "AC9 is a 1200M 11AC wireless router with Gigabit Ethernet port launched by Shenzhen Jixiang Tengda Technology Co., Ltd. in 2016.\n\r\n\r\nTenda AC9 has a denial of service vulnerability, which can be exploited by an attacker to cause a denial of service attack.",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17400"
      }
    ],
    "trust": 0.6
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17400",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17400"
      }
    ]
  },
  "id": "VAR-202104-1991",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17400"
      }
    ],
    "trust": 1.3881356
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17400"
      }
    ]
  },
  "last_update_date": "2022-05-04T09:27:43.063000Z",
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17400"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-04-08T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-17400"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-03-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-17400"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 has a denial of service vulnerability (CNVD-2021-17400)",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-17400"
      }
    ],
    "trust": 0.6
  }
}

var-202105-1656
Vulnerability from variot

AC9 is a 1200M 11AC wireless router with Gigabit Ethernet port launched by Shenzhen Jixiang Tengda Technology Co., Ltd. in 2016.

Tenda AC9 has a denial of service vulnerability, which can be exploited by attackers to cause the program to crash.

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202105-1656",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0v15.03.05.19(6318)"
      },
      {
        "model": "ac9 v15.03.06.42 multi",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v3.0"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-24932"
      }
    ]
  },
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "CNVD-2021-24932",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "CNVD",
            "id": "CNVD-2021-24932",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-24932"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "AC9 is a 1200M 11AC wireless router with Gigabit Ethernet port launched by Shenzhen Jixiang Tengda Technology Co., Ltd. in 2016.\n\r\n\r\nTenda AC9 has a denial of service vulnerability, which can be exploited by attackers to cause the program to crash.",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-24932"
      }
    ],
    "trust": 0.6
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-24932",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-24932"
      }
    ]
  },
  "id": "VAR-202105-1656",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-24932"
      }
    ],
    "trust": 1.3881356
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-24932"
      }
    ]
  },
  "last_update_date": "2022-05-04T09:27:42.435000Z",
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-24932"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-05-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-24932"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-04-06T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-24932"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 has a denial of service vulnerability (CNVD-2021-24932)",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-24932"
      }
    ],
    "trust": 0.6
  }
}

var-202203-0589
Vulnerability from variot

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetIpMacBind function. The Tenda AC9 is a wireless router from the Chinese company Tenda.

There is a buffer overflow vulnerability in Tenda AC9 15.03.2.21. The vulnerability arises from the fact that when the list parameter in the SetIpMacBind function performs operations on memory, the data boundary is not properly verified. An attacker can exploit this vulnerability to cause arbitrary command execution

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202203-0589",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.2.21"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.2.21"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26246"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25439"
      }
    ]
  },
  "cve": "CVE-2022-25439",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-25439",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-26246",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-25439",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-25439",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-26246",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202203-1849",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26246"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1849"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25439"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetIpMacBind function. The Tenda AC9 is a wireless router from the Chinese company Tenda. \n\r\n\r\nThere is a buffer overflow vulnerability in Tenda AC9 15.03.2.21. The vulnerability arises from the fact that when the list parameter in the SetIpMacBind function performs operations on memory, the data boundary is not properly verified. An attacker can exploit this vulnerability to cause arbitrary command execution",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25439"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-26246"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-25439",
        "trust": 2.2
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-26246",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1849",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26246"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1849"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25439"
      }
    ]
  },
  "id": "VAR-202203-0589",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26246"
      }
    ],
    "trust": 1.03844455
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26246"
      }
    ]
  },
  "last_update_date": "2024-11-23T23:03:55.127000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC9 Buffer Overflow Vulnerability (CNVD-2022-26246)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/328716"
      },
      {
        "title": "Tenda AC9 Fixes for command injection vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=186930"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26246"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1849"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25439"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.2,
        "url": "https://github.com/ephaha/iot_vuln/tree/main/tenda/ac9/8"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-25439/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26246"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1849"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25439"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26246"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1849"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25439"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-06T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-26246"
      },
      {
        "date": "2022-03-18T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1849"
      },
      {
        "date": "2022-03-18T21:15:08.247000",
        "db": "NVD",
        "id": "CVE-2022-25439"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-06T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-26246"
      },
      {
        "date": "2022-03-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1849"
      },
      {
        "date": "2024-11-21T06:52:11.203000",
        "db": "NVD",
        "id": "CVE-2022-25439"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1849"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 Buffer Overflow Vulnerability (CNVD-2022-26246)",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26246"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "command injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1849"
      }
    ],
    "trust": 0.6
  }
}

var-201810-0244
Vulnerability from variot

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "ssid" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. The AC series is a router product from Tenda. httpd is one of the HTTP server components. The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0244",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.05.19_cn"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac7 v15.03.06.44 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10 v15.03.06.23 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac15 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09141"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011966"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1338"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18707"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac10_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac7_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011966"
      }
    ]
  },
  "cve": "CVE-2018-18707",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-18707",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-09141",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-129293",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-18707",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-18707",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-18707",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-09141",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201810-1338",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-129293",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09141"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129293"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011966"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1338"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18707"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"ssid\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. The AC series is a router product from Tenda. httpd is one of the HTTP server components. The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-18707"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011966"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-09141"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129293"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-18707",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011966",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1338",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-09141",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-129293",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09141"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129293"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011966"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1338"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18707"
      }
    ]
  },
  "id": "VAR-201810-0244",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09141"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129293"
      }
    ],
    "trust": 1.4236169144444446
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09141"
      }
    ]
  },
  "last_update_date": "2024-11-23T23:12:02.625000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011966"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-129293"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011966"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18707"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/tenda.md"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18707"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18707"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09141"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129293"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011966"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1338"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18707"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09141"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129293"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011966"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1338"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18707"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-04-04T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-09141"
      },
      {
        "date": "2018-10-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129293"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011966"
      },
      {
        "date": "2018-10-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1338"
      },
      {
        "date": "2018-10-29T12:29:05.507000",
        "db": "NVD",
        "id": "CVE-2018-18707"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-04-04T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-09141"
      },
      {
        "date": "2018-12-14T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129293"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011966"
      },
      {
        "date": "2018-10-31T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1338"
      },
      {
        "date": "2024-11-21T03:56:24.870000",
        "db": "NVD",
        "id": "CVE-2018-18707"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1338"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Product buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011966"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer overflow",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1338"
      }
    ],
    "trust": 0.6
  }
}

var-202110-1423
Vulnerability from variot

Stack-based buffer overflow in Tenda AC-10U AC1200 Router US_AC10UV1.0RTL_V15.03.06.48_multi_TDE01 allows remote attackers to execute arbitrary code via the timeZone parameter to goform/SetSysTimeCfg. Tenda AC-10U AC1200 Routers contain an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC-10U is a wireless router of China Tenda (Tenda) company.

The Tenda AC-10U AC1200 router has a buffer overflow vulnerability. The vulnerability exists due to boundary errors when processing untrusted input

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202110-1423",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.06.42_multi"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac10u",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.06.48_multi_tde01"
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10u",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac-10u us ac10uv1.0rtl v15.03.06.48 multi tde01",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-84224"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014421"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-22079"
      }
    ]
  },
  "cve": "CVE-2020-22079",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2020-22079",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2021-84224",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2020-22079",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2020-22079",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-22079",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2020-22079",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-84224",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202110-2207",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-84224"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014421"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-2207"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-22079"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Stack-based buffer overflow in Tenda AC-10U AC1200 Router US_AC10UV1.0RTL_V15.03.06.48_multi_TDE01 allows remote attackers to execute arbitrary code via the timeZone parameter to goform/SetSysTimeCfg. Tenda AC-10U AC1200 Routers contain an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC-10U is a wireless router of China Tenda (Tenda) company. \n\r\n\r\nThe Tenda AC-10U AC1200 router has a buffer overflow vulnerability. The vulnerability exists due to boundary errors when processing untrusted input",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-22079"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014421"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-84224"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-22079",
        "trust": 3.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014421",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-84224",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-2207",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-84224"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014421"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-2207"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-22079"
      }
    ]
  },
  "id": "VAR-202110-1423",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-84224"
      }
    ],
    "trust": 1.319222275
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-84224"
      }
    ]
  },
  "last_update_date": "2024-08-14T14:44:14.816000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top\u00a0Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/default.html"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014421"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014421"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-22079"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/lyc-heng/routers/blob/main/routers/stack1.md"
      },
      {
        "trust": 2.2,
        "url": "https://github.com/1sd3d/tendown/tree/master/pocs/auth/bof11"
      },
      {
        "trust": 1.6,
        "url": "https://cwe.mitre.org/data/definitions/121.html"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-22079"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-84224"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014421"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-2207"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-22079"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-84224"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014421"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-2207"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-22079"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-11-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-84224"
      },
      {
        "date": "2022-10-18T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-014421"
      },
      {
        "date": "2021-10-29T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202110-2207"
      },
      {
        "date": "2021-10-29T11:15:08.310000",
        "db": "NVD",
        "id": "CVE-2020-22079"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-11-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-84224"
      },
      {
        "date": "2022-10-18T06:58:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-014421"
      },
      {
        "date": "2022-07-11T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202110-2207"
      },
      {
        "date": "2022-10-26T13:55:15.213000",
        "db": "NVD",
        "id": "CVE-2020-22079"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-2207"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0AC-10U\u00a0AC1200\u00a0 Out-of-Bounds Write Vulnerability in Router",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-014421"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202110-2207"
      }
    ],
    "trust": 0.6
  }
}

var-201911-0810
Vulnerability from variot

An exploitable command injection vulnerability exists in the /goform/WanParameterSetting functionality of Tenda AC9 Router AC1200 Smart Dual-Band Gigabit WiFi Route (AC9V1.0 Firmware V15.03.05.16multiTRU). A specially crafted HTTP POST request can cause a command injection in the DNS1 post parameters, resulting in code execution. An attacker can send HTTP POST request with command to trigger this vulnerability. Tenda AC9 is a wireless router.

Tenda AC9 /goform/WanParameterSetting implements a security vulnerability in handling DNS1 POST parameters, allowing remote attackers to use the vulnerability to submit special requests and execute arbitrary OS commands

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201911-0810",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9v1.0",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.05.14_en"
      },
      {
        "model": "ac9v1.0",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.05.16multitru"
      },
      {
        "model": "ac9v1.0",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.16multitru"
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35171"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012518"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5071"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tendacn:ac9v1.0_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012518"
      }
    ]
  },
  "cve": "CVE-2019-5071",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.2,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2019-5071",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.2,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 3.9,
            "id": "CNVD-2020-35171",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "talos-cna@cisco.com",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2019-5071",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2019-5071",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2019-5071",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "talos-cna@cisco.com",
            "id": "CVE-2019-5071",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2019-5071",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2020-35171",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201911-1255",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35171"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012518"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-1255"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5071"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5071"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An exploitable command injection vulnerability exists in the /goform/WanParameterSetting functionality of Tenda AC9 Router AC1200 Smart Dual-Band Gigabit WiFi Route (AC9V1.0 Firmware V15.03.05.16multiTRU). A specially crafted HTTP POST request can cause a command injection in the DNS1 post parameters, resulting in code execution. An attacker can send HTTP POST request with command to trigger this vulnerability. Tenda AC9 is a wireless router. \n\r\n\r\nTenda AC9 /goform/WanParameterSetting implements a security vulnerability in handling DNS1 POST parameters, allowing remote attackers to use the vulnerability to submit special requests and execute arbitrary OS commands",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-5071"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012518"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-35171"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-5071",
        "trust": 3.0
      },
      {
        "db": "TALOS",
        "id": "TALOS-2019-0861",
        "trust": 2.4
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012518",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-35171",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-1255",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35171"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012518"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-1255"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5071"
      }
    ]
  },
  "id": "VAR-201911-0810",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35171"
      }
    ],
    "trust": 1.03844455
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35171"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:59:38.411000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "AC9  /  Router  /  AC1200 Smart Dual-Band Gigabit WiFi Router",
        "trust": 0.8,
        "url": "https://tendacn.com/en/product/AC9.html"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012518"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-78",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012518"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5071"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://talosintelligence.com/vulnerability_reports/talos-2019-0861"
      },
      {
        "trust": 2.0,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-5071"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-5071"
      },
      {
        "trust": 0.6,
        "url": "https://www.talosintelligence.com/vulnerability_reports/talos-2019-0861"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35171"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012518"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-1255"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5071"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35171"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012518"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-1255"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5071"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-30T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-35171"
      },
      {
        "date": "2019-12-04T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-012518"
      },
      {
        "date": "2019-11-21T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201911-1255"
      },
      {
        "date": "2019-11-21T17:15:12.057000",
        "db": "NVD",
        "id": "CVE-2019-5071"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-30T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-35171"
      },
      {
        "date": "2019-12-04T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-012518"
      },
      {
        "date": "2022-04-20T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201911-1255"
      },
      {
        "date": "2024-11-21T04:44:17.677000",
        "db": "NVD",
        "id": "CVE-2019-5071"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-1255"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 Router AC1200 Smart Dual-Band Gigabit WiFi Route In  OS Command injection vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012518"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "operating system commend injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-1255"
      }
    ],
    "trust": 0.6
  }
}

var-202203-1213
Vulnerability from variot

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the firewallen parameter in the SetFirewallCfg function. The Tenda AC9 is a wireless router from the Chinese company Tenda.

There is a buffer overflow vulnerability in Tenda AC9 15.03.2.21. The vulnerability arises from the fact that the firewallen parameter in the SetFirewallCfg function does not properly verify the data boundary when performing operations on memory. An attacker can exploit this vulnerability to cause arbitrary command execution

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202203-1213",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.2.21"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.2.21"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26247"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25434"
      }
    ]
  },
  "cve": "CVE-2022-25434",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-25434",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-26247",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-25434",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-25434",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-26247",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202203-1853",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26247"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1853"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25434"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the firewallen parameter in the SetFirewallCfg function. The Tenda AC9 is a wireless router from the Chinese company Tenda. \n\r\n\r\nThere is a buffer overflow vulnerability in Tenda AC9 15.03.2.21. The vulnerability arises from the fact that the firewallen parameter in the SetFirewallCfg function does not properly verify the data boundary when performing operations on memory. An attacker can exploit this vulnerability to cause arbitrary command execution",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25434"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-26247"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-25434",
        "trust": 2.2
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-26247",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1853",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26247"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1853"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25434"
      }
    ]
  },
  "id": "VAR-202203-1213",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26247"
      }
    ],
    "trust": 1.03844455
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26247"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:57:46.849000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC9 Buffer Overflow Vulnerability (CNVD-2022-26247)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/328706"
      },
      {
        "title": "Tenda AC9 Fixes for command injection vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=186934"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26247"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1853"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25434"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.2,
        "url": "https://github.com/ephaha/iot_vuln/tree/main/tenda/ac9/6"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-25434/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26247"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1853"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25434"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26247"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1853"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25434"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-06T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-26247"
      },
      {
        "date": "2022-03-18T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1853"
      },
      {
        "date": "2022-03-18T21:15:08.093000",
        "db": "NVD",
        "id": "CVE-2022-25434"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-06T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-26247"
      },
      {
        "date": "2022-03-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1853"
      },
      {
        "date": "2024-11-21T06:52:10.657000",
        "db": "NVD",
        "id": "CVE-2022-25434"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1853"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 Buffer Overflow Vulnerability (CNVD-2022-26247)",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26247"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "command injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1853"
      }
    ],
    "trust": 0.6
  }
}

var-202208-2264
Vulnerability from variot

Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the mask parameter at /goform/WanParameterSetting. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202208-2264",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac9  firmware  15.03.05.19"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015958"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36571"
      }
    ]
  },
  "cve": "CVE-2022-36571",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.2,
            "id": "CVE-2022-36571",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.2,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-36571",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "High",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-36571",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-36571",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202208-4520",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015958"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4520"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36571"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the mask parameter at /goform/WanParameterSetting. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-36571"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015958"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-36571",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015958",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4520",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015958"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4520"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36571"
      }
    ]
  },
  "id": "VAR-202208-2264",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.43844455
  },
  "last_update_date": "2024-08-14T14:24:36.155000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015958"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36571"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/cyberunicorniot/iotvuln/blob/main/tenda_ac9/2/tenda_ac9_wanparametersetting.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-36571"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-36571/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015958"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4520"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36571"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015958"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4520"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36571"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-09-29T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-015958"
      },
      {
        "date": "2022-08-31T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202208-4520"
      },
      {
        "date": "2022-08-31T20:15:09.020000",
        "db": "NVD",
        "id": "CVE-2022-36571"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-09-29T08:06:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-015958"
      },
      {
        "date": "2022-09-05T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202208-4520"
      },
      {
        "date": "2022-09-02T22:29:39.533000",
        "db": "NVD",
        "id": "CVE-2022-36571"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4520"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015958"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4520"
      }
    ],
    "trust": 0.6
  }
}

var-201810-0276
Vulnerability from variot

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'startIp' and 'endIp' parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. A buffer overflow vulnerability exists in httpd in several Tenda products that an attacker can exploit to cause a denial of service (the return address of the override function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0276",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.05.19_cn"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac7 v15.03.06.44 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10 v15.03.06.23 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac15 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01885"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011970"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1357"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18730"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac10_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac7_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011970"
      }
    ]
  },
  "cve": "CVE-2018-18730",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-18730",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-01885",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-129319",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-18730",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-18730",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-18730",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-01885",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201810-1357",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-129319",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01885"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129319"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011970"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1357"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18730"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027startIp\u0027 and \u0027endIp\u0027 parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. A buffer overflow vulnerability exists in httpd in several Tenda products that an attacker can exploit to cause a denial of service (the return address of the override function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-18730"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011970"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-01885"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129319"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-18730",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011970",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1357",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-01885",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-129319",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01885"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129319"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011970"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1357"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18730"
      }
    ]
  },
  "id": "VAR-201810-0276",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01885"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129319"
      }
    ],
    "trust": 1.4236169144444446
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01885"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:17:17.746000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011970"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-129319"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011970"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18730"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://github.com/zillr0/routers/blob/master/tenda/stack3.md"
      },
      {
        "trust": 1.4,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18730"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18730"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01885"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129319"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011970"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1357"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18730"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01885"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129319"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011970"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1357"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18730"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-01885"
      },
      {
        "date": "2018-10-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129319"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011970"
      },
      {
        "date": "2018-10-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1357"
      },
      {
        "date": "2018-10-29T12:29:07.727000",
        "db": "NVD",
        "id": "CVE-2018-18730"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-01885"
      },
      {
        "date": "2018-12-14T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129319"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011970"
      },
      {
        "date": "2018-10-31T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1357"
      },
      {
        "date": "2024-11-21T03:56:28.363000",
        "db": "NVD",
        "id": "CVE-2018-18730"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1357"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Product buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011970"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer overflow",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1357"
      }
    ],
    "trust": 0.6
  }
}

var-202005-0460
Vulnerability from variot

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/SetNetControlList list parameter for a POST request, a value is directly used in a strcpy to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202005-0460",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.06.42_multi"
      },
      {
        "model": "ac6",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19_multi_td01"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19_multi_td01"
      },
      {
        "model": "ac15",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac6",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac6 v15.03.05.19 multi td01",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0v15.03.05.19(6318)"
      },
      {
        "model": "ac9 v15.03.06.42 multi",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v3.0"
      },
      {
        "model": "ac15 v15.03.05.19 multi td01",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19(6318)"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31409"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005748"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13394"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tendacn:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac6_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005748"
      }
    ]
  },
  "cve": "CVE-2020-13394",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2020-13394",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 7.5,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-005748",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2020-31409",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2020-13394",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-005748",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-13394",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "JVNDB-2020-005748",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2020-31409",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202005-1144",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31409"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005748"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1144"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13394"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the /goform/SetNetControlList list parameter for a POST request, a value is directly used in a strcpy to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-13394"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005748"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-31409"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-13394",
        "trust": 3.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005748",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-31409",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1144",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31409"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005748"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1144"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13394"
      }
    ]
  },
  "id": "VAR-202005-0460",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31409"
      }
    ],
    "trust": 1.3076761016666667
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31409"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:58:17.264000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://tendacn.com/en"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005748"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005748"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13394"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://joel-malwarebenchmark.github.io/blog/2020/04/28/cve-2020-13394-tenda-vulnerability/"
      },
      {
        "trust": 2.0,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-13394"
      },
      {
        "trust": 1.6,
        "url": "https://joel-malwarebenchmark.github.io"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-13394"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31409"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005748"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1144"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13394"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31409"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005748"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1144"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13394"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-31409"
      },
      {
        "date": "2020-06-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-005748"
      },
      {
        "date": "2020-05-22T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-1144"
      },
      {
        "date": "2020-05-22T17:15:11.363000",
        "db": "NVD",
        "id": "CVE-2020-13394"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-31409"
      },
      {
        "date": "2020-06-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-005748"
      },
      {
        "date": "2020-05-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-1144"
      },
      {
        "date": "2024-11-21T05:01:10.413000",
        "db": "NVD",
        "id": "CVE-2020-13394"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1144"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Classic buffer overflow vulnerability in device",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005748"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1144"
      }
    ],
    "trust": 0.6
  }
}

var-202308-4200
Vulnerability from variot

Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware and AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202308-4200",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac5",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.28"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "5.03.06.42_multi"
      },
      {
        "model": "ac5",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011115"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41553"
      }
    ]
  },
  "cve": "CVE-2023-41553",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-41553",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-41553",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-41553",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-41553",
            "trust": 0.8,
            "value": "Critical"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011115"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41553"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware and AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-41553"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011115"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-41553",
        "trust": 2.6
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011115",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011115"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41553"
      }
    ]
  },
  "id": "VAR-202308-4200",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.43844455
  },
  "last_update_date": "2024-08-14T15:20:57.244000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011115"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41553"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromsetroutestatic/1.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-41553"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011115"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41553"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011115"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41553"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-12-12T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-011115"
      },
      {
        "date": "2023-08-30T13:15:13.280000",
        "db": "NVD",
        "id": "CVE-2023-41553"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-12-12T06:21:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-011115"
      },
      {
        "date": "2023-08-31T18:40:45.207000",
        "db": "NVD",
        "id": "CVE-2023-41553"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 firmware and \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011115"
      }
    ],
    "trust": 0.8
  }
}

var-201904-0690
Vulnerability from variot

An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router's web server (httpd). When processing the list parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow. Tenda AC7 , AC9 , AC10 The firmware contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. Tenda AC7 and others are all wireless routers from China's Tenda. This vulnerability originates from a network system or product that incorrectly validates data boundaries when performing operations on memory, causing incorrect read and write operations to be associated with other memory locations

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201904-0690",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10",
        "scope": "lte",
        "trust": 1.8,
        "vendor": "tenda",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac7",
        "scope": "lte",
        "trust": 1.8,
        "vendor": "tenda",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac9",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac9",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac7 v15.03.06.44 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10 \u003c=v15.03.06.23 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 \u003c=v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-13773"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015359"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14559"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac10_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac7_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015359"
      }
    ]
  },
  "cve": "CVE-2018-14559",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-14559",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-13773",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-124730",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-14559",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-14559",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-14559",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-13773",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201904-1170",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-124730",
            "trust": 0.1,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2018-14559",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-13773"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124730"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-14559"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015359"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-1170"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14559"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router\u0027s web server (httpd). When processing the list parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow. Tenda AC7 , AC9 , AC10 The firmware contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. Tenda AC7 and others are all wireless routers from China\u0027s Tenda. This vulnerability originates from a network system or product that incorrectly validates data boundaries when performing operations on memory, causing incorrect read and write operations to be associated with other memory locations",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-14559"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015359"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-13773"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124730"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-14559"
      }
    ],
    "trust": 2.34
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-14559",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015359",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-1170",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-13773",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-124730",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-14559",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-13773"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124730"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-14559"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015359"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-1170"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14559"
      }
    ]
  },
  "id": "VAR-201904-0690",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-13773"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124730"
      }
    ],
    "trust": 1.440988034
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "IoT"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-13773"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:17:05.252000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015359"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-124730"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015359"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14559"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.2,
        "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-02/tenda.md"
      },
      {
        "trust": 2.0,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14559"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14559"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/119.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-13773"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124730"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-14559"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015359"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-1170"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14559"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-13773"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124730"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-14559"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015359"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-1170"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14559"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-05-10T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-13773"
      },
      {
        "date": "2019-04-25T00:00:00",
        "db": "VULHUB",
        "id": "VHN-124730"
      },
      {
        "date": "2019-04-25T00:00:00",
        "db": "VULMON",
        "id": "CVE-2018-14559"
      },
      {
        "date": "2019-05-29T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-015359"
      },
      {
        "date": "2019-04-25T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201904-1170"
      },
      {
        "date": "2019-04-25T20:29:00.287000",
        "db": "NVD",
        "id": "CVE-2018-14559"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-05-10T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-13773"
      },
      {
        "date": "2019-05-02T00:00:00",
        "db": "VULHUB",
        "id": "VHN-124730"
      },
      {
        "date": "2019-05-02T00:00:00",
        "db": "VULMON",
        "id": "CVE-2018-14559"
      },
      {
        "date": "2019-05-29T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-015359"
      },
      {
        "date": "2019-04-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201904-1170"
      },
      {
        "date": "2024-11-21T03:49:18.637000",
        "db": "NVD",
        "id": "CVE-2018-14559"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Buffer error vulnerability in product firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015359"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-1170"
      }
    ],
    "trust": 0.6
  }
}

var-202203-0590
Vulnerability from variot

Tenda AC9 v15.03.2.21 was discovered to contain a remote command execution (RCE) vulnerability via the vlanid parameter in the SetIPTVCfg function. The Tenda AC9 is a wireless router from the Chinese company Tenda. The vulnerability stems from the fact that the vlanid parameter in the SetIPTVCfg function fails to properly filter the special elements that construct the code segment

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202203-0590",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.2.21"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.2.21"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26245"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25441"
      }
    ]
  },
  "cve": "CVE-2022-25441",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-25441",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-26245",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-25441",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-25441",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-26245",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202203-1847",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26245"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1847"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25441"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 v15.03.2.21 was discovered to contain a remote command execution (RCE) vulnerability via the vlanid parameter in the SetIPTVCfg function. The Tenda AC9 is a wireless router from the Chinese company Tenda. The vulnerability stems from the fact that the vlanid parameter in the SetIPTVCfg function fails to properly filter the special elements that construct the code segment",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25441"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-26245"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-25441",
        "trust": 2.2
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-26245",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1847",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26245"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1847"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25441"
      }
    ]
  },
  "id": "VAR-202203-0590",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26245"
      }
    ],
    "trust": 1.03844455
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26245"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:47:29.716000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC9 Command Injection Vulnerability (CNVD-2022-26245)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/328711"
      },
      {
        "title": "Tenda AC9 Fixes for command injection vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=186928"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26245"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1847"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-78",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25441"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.2,
        "url": "https://github.com/ephaha/iot_vuln/tree/main/tenda/ac9/12"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-25441/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26245"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1847"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25441"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26245"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1847"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25441"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-06T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-26245"
      },
      {
        "date": "2022-03-18T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1847"
      },
      {
        "date": "2022-03-18T21:15:08.323000",
        "db": "NVD",
        "id": "CVE-2022-25441"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-06T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-26245"
      },
      {
        "date": "2022-03-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1847"
      },
      {
        "date": "2024-11-21T06:52:11.467000",
        "db": "NVD",
        "id": "CVE-2022-25441"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1847"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 Command Injection Vulnerability (CNVD-2022-26245)",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26245"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "command injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1847"
      }
    ],
    "trust": 0.6
  }
}

var-202005-0457
Vulnerability from variot

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/SetSpeedWan speed_dir parameter for a POST request, a value is directly used in a sprintf to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202005-0457",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.06.42_multi"
      },
      {
        "model": "ac6",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19_multi_td01"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "v15.03.05.19_multi_td01"
      },
      {
        "model": "ac15",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac6",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac6 v15.03.05.19 multi td01",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac9 v15.03.06.42 multi",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v3.0"
      },
      {
        "model": "ac15 v15.03.05.19 multi td01",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0"
      },
      {
        "model": "ac18 ) cn",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.05.19(6318"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31397"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005745"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13391"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tendacn:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac6_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005745"
      }
    ]
  },
  "cve": "CVE-2020-13391",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2020-13391",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.1,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 7.5,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-005745",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2020-31397",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2020-13391",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-005745",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-13391",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "JVNDB-2020-005745",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2020-31397",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202005-1141",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULMON",
            "id": "CVE-2020-13391",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31397"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13391"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005745"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1141"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13391"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the /goform/SetSpeedWan speed_dir parameter for a POST request, a value is directly used in a sprintf to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks. plural Tenda A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Tenda AC9 and others are all wireless routers of China Tenda",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-13391"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005745"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-31397"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13391"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-13391",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005745",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-31397",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1141",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13391",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31397"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13391"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005745"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1141"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13391"
      }
    ]
  },
  "id": "VAR-202005-0457",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31397"
      }
    ],
    "trust": 1.38075707625
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31397"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:41:05.729000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://tendacn.com/en"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005745"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005745"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13391"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://joel-malwarebenchmark.github.io/blog/2020/04/28/cve-2020-13391-tenda-vulnerability/"
      },
      {
        "trust": 2.0,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-13391"
      },
      {
        "trust": 1.7,
        "url": "https://joel-malwarebenchmark.github.io"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-13391"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/120.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31397"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13391"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005745"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1141"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13391"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-31397"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-13391"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005745"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1141"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-13391"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-31397"
      },
      {
        "date": "2020-05-22T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-13391"
      },
      {
        "date": "2020-06-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-005745"
      },
      {
        "date": "2020-05-22T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-1141"
      },
      {
        "date": "2020-05-22T17:15:11.177000",
        "db": "NVD",
        "id": "CVE-2020-13391"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-31397"
      },
      {
        "date": "2020-05-27T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-13391"
      },
      {
        "date": "2020-06-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-005745"
      },
      {
        "date": "2020-05-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202005-1141"
      },
      {
        "date": "2024-11-21T05:01:09.953000",
        "db": "NVD",
        "id": "CVE-2020-13391"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1141"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Classic buffer overflow vulnerability in device",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-005745"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202005-1141"
      }
    ],
    "trust": 0.6
  }
}

var-202208-2271
Vulnerability from variot

Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the list parameter at /goform/setPptpUserList. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202208-2271",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac9  firmware  15.03.05.19"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015961"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36568"
      }
    ]
  },
  "cve": "CVE-2022-36568",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2022-36568",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-36568",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-36568",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-36568",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202208-4525",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015961"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4525"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36568"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the list parameter at /goform/setPptpUserList. Shenzhen Tenda Technology Co.,Ltd. of AC9 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-36568"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015961"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-36568",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015961",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4525",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015961"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4525"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36568"
      }
    ]
  },
  "id": "VAR-202208-2271",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.43844455
  },
  "last_update_date": "2024-08-14T15:37:27.361000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015961"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36568"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/cyberunicorniot/iotvuln/blob/main/tenda_ac9/3/tenda_ac9_setpptpuserlist.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-36568"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-36568/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015961"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4525"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36568"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015961"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4525"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36568"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-09-29T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-015961"
      },
      {
        "date": "2022-08-31T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202208-4525"
      },
      {
        "date": "2022-08-31T20:15:08.883000",
        "db": "NVD",
        "id": "CVE-2022-36568"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-09-29T08:06:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-015961"
      },
      {
        "date": "2022-09-05T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202208-4525"
      },
      {
        "date": "2022-09-02T21:33:38.403000",
        "db": "NVD",
        "id": "CVE-2022-36568"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4525"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015961"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-4525"
      }
    ],
    "trust": 0.6
  }
}

var-201810-0277
Vulnerability from variot

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'deviceMac' parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. A buffer overflow vulnerability exists in httpd in several Tenda products that an attacker can exploit to cause a denial of service (the return address of the override function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0277",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 1.8,
        "vendor": "tenda",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.8,
        "vendor": "tenda",
        "version": "15.03.05.19_cn"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 1.8,
        "vendor": "tenda",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac7 v15.03.06.44 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10 v15.03.06.23 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac15 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01884"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013980"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18731"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac10_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac7_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013980"
      }
    ]
  },
  "cve": "CVE-2018-18731",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-18731",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-01884",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-129320",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-18731",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-18731",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-18731",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-01884",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201810-1358",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-129320",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01884"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129320"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013980"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1358"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18731"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceMac\u0027 parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. A buffer overflow vulnerability exists in httpd in several Tenda products that an attacker can exploit to cause a denial of service (the return address of the override function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-18731"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013980"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-01884"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129320"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-18731",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013980",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1358",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-01884",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-129320",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01884"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129320"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013980"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1358"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18731"
      }
    ]
  },
  "id": "VAR-201810-0277",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01884"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129320"
      }
    ],
    "trust": 1.4236169144444446
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01884"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:52:47.617000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013980"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-129320"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013980"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18731"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.7,
        "url": "https://github.com/zillr0/routers/blob/master/tenda/stack4.md"
      },
      {
        "trust": 1.4,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18731"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18731"
      },
      {
        "trust": 0.8,
        "url": "https://github.com/zillr0/routers/blob/master/tenda/stack2.md"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01884"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129320"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013980"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1358"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18731"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01884"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129320"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013980"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1358"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18731"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-01884"
      },
      {
        "date": "2018-10-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129320"
      },
      {
        "date": "2019-03-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-013980"
      },
      {
        "date": "2018-10-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1358"
      },
      {
        "date": "2018-10-29T12:29:07.837000",
        "db": "NVD",
        "id": "CVE-2018-18731"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-01884"
      },
      {
        "date": "2019-01-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129320"
      },
      {
        "date": "2019-03-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-013980"
      },
      {
        "date": "2019-04-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1358"
      },
      {
        "date": "2024-11-21T03:56:28.527000",
        "db": "NVD",
        "id": "CVE-2018-18731"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1358"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Product buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013980"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1358"
      }
    ],
    "trust": 0.6
  }
}

var-202308-4265
Vulnerability from variot

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware, AC7 firmware, AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202308-4265",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac5",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.28"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.42_multi"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.44"
      },
      {
        "model": "ac7",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac5",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011504"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41559"
      }
    ]
  },
  "cve": "CVE-2023-41559",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-41559",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-41559",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-41559",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-41559",
            "trust": 0.8,
            "value": "Critical"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011504"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41559"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware, AC7 firmware, AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-41559"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011504"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-41559",
        "trust": 2.6
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011504",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011504"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41559"
      }
    ]
  },
  "id": "VAR-202308-4265",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.43844455
  },
  "last_update_date": "2024-08-14T15:20:57.186000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011504"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41559"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromnatstaticsetting/1.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-41559"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011504"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41559"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011504"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41559"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-12-13T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-011504"
      },
      {
        "date": "2023-08-30T13:15:14.280000",
        "db": "NVD",
        "id": "CVE-2023-41559"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-12-13T07:09:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-011504"
      },
      {
        "date": "2023-09-01T19:10:58.247000",
        "db": "NVD",
        "id": "CVE-2023-41559"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011504"
      }
    ],
    "trust": 0.8
  }
}

var-202308-4213
Vulnerability from variot

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function. AC10 firmware, ac1206 firmware, AC8 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202308-4213",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac5",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.28"
      },
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.10.13"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.42_multi"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.44"
      },
      {
        "model": "ac8",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.34.06"
      },
      {
        "model": "ac6",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.23"
      },
      {
        "model": "ac1206",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.23"
      },
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.23"
      },
      {
        "model": "ac1206",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac6",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac5",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac7",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac8",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021658"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38937"
      }
    ]
  },
  "cve": "CVE-2023-38937",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-38937",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-38937",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-38937",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-38937",
            "trust": 0.8,
            "value": "Critical"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021658"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38937"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function. AC10 firmware, ac1206 firmware, AC8 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-38937"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021658"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-38937",
        "trust": 2.6
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021658",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021658"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38937"
      }
    ]
  },
  "id": "VAR-202308-4213",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.3871988366666666
  },
  "last_update_date": "2024-08-14T15:26:26.130000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021658"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38937"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/formsetvirtualser/readme.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-38937"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021658"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38937"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021658"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38937"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-01-19T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-021658"
      },
      {
        "date": "2023-08-07T19:15:11.413000",
        "db": "NVD",
        "id": "CVE-2023-38937"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-01-19T07:51:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-021658"
      },
      {
        "date": "2023-08-10T18:22:01.703000",
        "db": "NVD",
        "id": "CVE-2023-38937"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021658"
      }
    ],
    "trust": 0.8
  }
}

var-202307-1306
Vulnerability from variot

Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202307-1306",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "f1202",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "1.0br"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "3.0"
      },
      {
        "model": "ac5",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "1.0"
      },
      {
        "model": "f1202",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "1.2.0.20\\(408\\)"
      },
      {
        "model": "ac1206",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "1.0"
      },
      {
        "model": "fh1202",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "1.2.0.19_en"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "1.0"
      },
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "1.0"
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-37716"
      }
    ]
  },
  "cve": "CVE-2023-37716",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-37716",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-37716",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202307-1255",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202307-1255"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-37716"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-37716"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-37716"
      }
    ],
    "trust": 0.99
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-37716",
        "trust": 1.7
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202307-1255",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-37716",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-37716"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202307-1255"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-37716"
      }
    ]
  },
  "id": "VAR-202307-1306",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.5256526420000001
  },
  "last_update_date": "2024-08-14T14:09:54.108000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-37716"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.7,
        "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/fromnatstaticsetting/report.md"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2023-37716/"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37716"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-37716"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202307-1255"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-37716"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULMON",
        "id": "CVE-2023-37716"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202307-1255"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-37716"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-07-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-37716"
      },
      {
        "date": "2023-07-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202307-1255"
      },
      {
        "date": "2023-07-14T00:15:09.430000",
        "db": "NVD",
        "id": "CVE-2023-37716"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-07-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-37716"
      },
      {
        "date": "2023-07-24T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202307-1255"
      },
      {
        "date": "2023-07-21T14:33:30.690000",
        "db": "NVD",
        "id": "CVE-2023-37716"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202307-1255"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda F1202 Buffer error vulnerability",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202307-1255"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202307-1255"
      }
    ],
    "trust": 0.6
  }
}

var-201911-0811
Vulnerability from variot

An exploitable command injection vulnerability exists in the /goform/WanParameterSetting functionality of Tenda AC9 Router AC1200 Smart Dual-Band Gigabit WiFi Route (AC9V1.0 Firmware V15.03.05.16multiTRU). A specially crafted HTTP POST request can cause a command injection in the DNS2 post parameters, resulting in code execution. An attacker can send HTTP POST request with command to trigger this vulnerability. Tenda AC9 is a wireless router from China's Tenda.

The / goform / WanParameterSetting function in Tenda AC9 has an operating system command injection vulnerability. The vulnerability stems from the fact that the network system or product did not properly filter the special characters, commands, etc. during the process of constructing the executable command of the operating system by external input data

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201911-0811",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9v1.0",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.05.14_en"
      },
      {
        "model": "ac9v1.0",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.05.16multitru"
      },
      {
        "model": "ac9v1.0",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.16multitru"
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-02715"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012519"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5072"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tendacn:ac9v1.0_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012519"
      }
    ]
  },
  "cve": "CVE-2019-5072",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.6,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 3.9,
            "id": "CVE-2019-5072",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.2,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 3.9,
            "id": "CNVD-2020-02715",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "talos-cna@cisco.com",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2019-5072",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2019-5072",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2019-5072",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "talos-cna@cisco.com",
            "id": "CVE-2019-5072",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2019-5072",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2020-02715",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201911-1257",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-02715"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012519"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-1257"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5072"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5072"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An exploitable command injection vulnerability exists in the /goform/WanParameterSetting functionality of Tenda AC9 Router AC1200 Smart Dual-Band Gigabit WiFi Route (AC9V1.0 Firmware V15.03.05.16multiTRU). A specially crafted HTTP POST request can cause a command injection in the DNS2 post parameters, resulting in code execution. An attacker can send HTTP POST request with command to trigger this vulnerability. Tenda AC9 is a wireless router from China\u0027s Tenda. \n\nThe / goform / WanParameterSetting function in Tenda AC9 has an operating system command injection vulnerability. The vulnerability stems from the fact that the network system or product did not properly filter the special characters, commands, etc. during the process of constructing the executable command of the operating system by external input data",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-5072"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012519"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-02715"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-5072",
        "trust": 3.0
      },
      {
        "db": "TALOS",
        "id": "TALOS-2019-0861",
        "trust": 3.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012519",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-02715",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-1257",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-02715"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012519"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-1257"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5072"
      }
    ]
  },
  "id": "VAR-201911-0811",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-02715"
      }
    ],
    "trust": 1.03844455
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-02715"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:59:38.384000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "AC9 / Router / AC1200 Smart Dual-Band Gigabit WiFi Router",
        "trust": 0.8,
        "url": "https://tendacn.com/en/product/AC9.html"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012519"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-78",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012519"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5072"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://talosintelligence.com/vulnerability_reports/talos-2019-0861"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-5072"
      },
      {
        "trust": 1.2,
        "url": "https://www.talosintelligence.com/vulnerability_reports/talos-2019-0861"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-5072"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-02715"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012519"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-1257"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5072"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-02715"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012519"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-1257"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5072"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-01-19T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-02715"
      },
      {
        "date": "2019-12-04T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-012519"
      },
      {
        "date": "2019-11-21T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201911-1257"
      },
      {
        "date": "2019-11-21T17:15:12.147000",
        "db": "NVD",
        "id": "CVE-2019-5072"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-01-19T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-02715"
      },
      {
        "date": "2019-12-04T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-012519"
      },
      {
        "date": "2022-04-20T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201911-1257"
      },
      {
        "date": "2024-11-21T04:44:17.803000",
        "db": "NVD",
        "id": "CVE-2019-5072"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-1257"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 Router AC1200 Smart Dual-Band Gigabit WiFi Route In  OS Command injection vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-012519"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "operating system commend injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-1257"
      }
    ],
    "trust": 0.6
  }
}

var-202202-0849
Vulnerability from variot

Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function openSchedWifi. Tenda AC9 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC9 is a wireless router from the Chinese company Tenda.

A stack overflow vulnerability exists in Tenda AC9, which could be exploited by an attacker to cause arbitrary code execution

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202202-0849",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "v15.03.2.21_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac9  firmware  15.03.2.21_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 v15.03.2.21 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-22749"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006049"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25418"
      }
    ]
  },
  "cve": "CVE-2022-25418",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-25418",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-22749",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-25418",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-25418",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-25418",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-25418",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-22749",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202202-1827",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-22749"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006049"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1827"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25418"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function openSchedWifi. Tenda AC9 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC9 is a wireless router from the Chinese company Tenda. \n\r\n\r\nA stack overflow vulnerability exists in Tenda AC9, which could be exploited by an attacker to cause arbitrary code execution",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25418"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006049"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-22749"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-25418",
        "trust": 3.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006049",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-22749",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1827",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-22749"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006049"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1827"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25418"
      }
    ]
  },
  "id": "VAR-202202-0849",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-22749"
      }
    ],
    "trust": 1.319222275
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-22749"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:24:59.236000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top\u00a0Page",
        "trust": 0.8,
        "url": "https://www.tendacn.com/default.html"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006049"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006049"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25418"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/ephaha/iot_vuln/tree/main/tenda/ac9/2"
      },
      {
        "trust": 2.0,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-25418"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-25418/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-22749"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006049"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1827"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25418"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-22749"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006049"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1827"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25418"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-03-25T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-22749"
      },
      {
        "date": "2023-06-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-006049"
      },
      {
        "date": "2022-02-24T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202202-1827"
      },
      {
        "date": "2022-02-24T15:15:31.940000",
        "db": "NVD",
        "id": "CVE-2022-25418"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-03-25T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-22749"
      },
      {
        "date": "2023-06-26T08:40:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-006049"
      },
      {
        "date": "2022-03-10T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202202-1827"
      },
      {
        "date": "2024-11-21T06:52:09.750000",
        "db": "NVD",
        "id": "CVE-2022-25418"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1827"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0AC9\u00a0 Out-of-bounds write vulnerability in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006049"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1827"
      }
    ],
    "trust": 0.6
  }
}

var-202307-1183
Vulnerability from variot

Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202307-1183",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "f1202",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "1.0br"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "3.0"
      },
      {
        "model": "ac5",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "1.0"
      },
      {
        "model": "f1202",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "1.2.0.20\\(408\\)"
      },
      {
        "model": "ac1206",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "1.0"
      },
      {
        "model": "fh1202",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "1.2.0.19_en"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "1.0"
      },
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "1.0"
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-37717"
      }
    ]
  },
  "cve": "CVE-2023-37717",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-37717",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-37717",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202307-1259",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202307-1259"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-37717"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-37717"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-37717"
      }
    ],
    "trust": 0.99
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-37717",
        "trust": 1.7
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202307-1259",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-37717",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-37717"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202307-1259"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-37717"
      }
    ]
  },
  "id": "VAR-202307-1183",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.5256526420000001
  },
  "last_update_date": "2024-08-14T15:41:40.794000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Tenda F1202 Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=247158"
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202307-1259"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-37717"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.7,
        "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/fromdhcplistclient/repot.md"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2023-37717/"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37717"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-37717"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202307-1259"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-37717"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULMON",
        "id": "CVE-2023-37717"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202307-1259"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-37717"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-07-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-37717"
      },
      {
        "date": "2023-07-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202307-1259"
      },
      {
        "date": "2023-07-14T00:15:09.477000",
        "db": "NVD",
        "id": "CVE-2023-37717"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-07-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-37717"
      },
      {
        "date": "2023-07-24T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202307-1259"
      },
      {
        "date": "2023-07-21T14:31:56.167000",
        "db": "NVD",
        "id": "CVE-2023-37717"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202307-1259"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda F1202 Buffer error vulnerability",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202307-1259"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202307-1259"
      }
    ],
    "trust": 0.6
  }
}

var-202308-4027
Vulnerability from variot

Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function. ac1206 firmware, AC5 firmware, AC9 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202308-4027",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac5",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.28"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.42_multi"
      },
      {
        "model": "ac8",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.34.06"
      },
      {
        "model": "ac1206",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.23"
      },
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.10.13"
      },
      {
        "model": "ac1206",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac5",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac8",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021660"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38935"
      }
    ]
  },
  "cve": "CVE-2023-38935",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-38935",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-38935",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-38935",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-38935",
            "trust": 0.8,
            "value": "Critical"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021660"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38935"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function. ac1206 firmware, AC5 firmware, AC9 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-38935"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021660"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-38935",
        "trust": 2.6
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021660",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021660"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38935"
      }
    ]
  },
  "id": "VAR-202308-4027",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.3871988366666666
  },
  "last_update_date": "2024-08-14T14:16:59.792000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021660"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38935"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/formsetqosband/readme.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-38935"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021660"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38935"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021660"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38935"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-01-19T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-021660"
      },
      {
        "date": "2023-08-07T19:15:11.277000",
        "db": "NVD",
        "id": "CVE-2023-38935"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-01-19T07:51:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-021660"
      },
      {
        "date": "2023-08-10T17:18:24.527000",
        "db": "NVD",
        "id": "CVE-2023-38935"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021660"
      }
    ],
    "trust": 0.8
  }
}

var-202208-1445
Vulnerability from variot

Tenda AC9 V15.03.2.13 is vulnerable to Buffer Overflow via httpd, form_fast_setting_wifi_set. httpd. Tenda of AC9 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. The Tenda AC9 is a wireless router from the Chinese company Tenda. An authenticated local attacker could exploit this vulnerability to cause a denial of service

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202208-1445",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.2.13"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac9  firmware  15.03.2.13"
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.2.13"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75822"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014941"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36233"
      }
    ]
  },
  "cve": "CVE-2022-36233",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 4.9,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CNVD-2022-75822",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:L/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 1.8,
            "id": "CVE-2022-36233",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 5.5,
            "baseSeverity": "Medium",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2022-36233",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-36233",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-36233",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-75822",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202208-3593",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75822"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014941"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3593"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36233"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 V15.03.2.13 is vulnerable to Buffer Overflow via httpd, form_fast_setting_wifi_set. httpd. Tenda of AC9 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. The Tenda AC9 is a wireless router from the Chinese company Tenda. An authenticated local attacker could exploit this vulnerability to cause a denial of service",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-36233"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014941"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-75822"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-36233",
        "trust": 3.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014941",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-75822",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3593",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75822"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014941"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3593"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36233"
      }
    ]
  },
  "id": "VAR-202208-1445",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75822"
      }
    ],
    "trust": 1.03844455
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75822"
      }
    ]
  },
  "last_update_date": "2024-08-14T14:49:39.847000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014941"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36233"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "http://tenda.com"
      },
      {
        "trust": 2.4,
        "url": "https://www.cnblogs.com/amalll/p/16606980.html"
      },
      {
        "trust": 2.0,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-36233"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-36233/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75822"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014941"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3593"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36233"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75822"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014941"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3593"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36233"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-11-10T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-75822"
      },
      {
        "date": "2023-09-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-014941"
      },
      {
        "date": "2022-08-19T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202208-3593"
      },
      {
        "date": "2022-08-19T22:15:09.110000",
        "db": "NVD",
        "id": "CVE-2022-36233"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-11-10T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-75822"
      },
      {
        "date": "2023-09-22T08:26:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-014941"
      },
      {
        "date": "2022-08-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202208-3593"
      },
      {
        "date": "2022-08-21T03:32:01.793000",
        "db": "NVD",
        "id": "CVE-2022-36233"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3593"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0 of \u00a0AC9\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014941"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3593"
      }
    ],
    "trust": 0.6
  }
}

var-202308-3958
Vulnerability from variot

Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware and AC7 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202308-3958",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "5.03.06.42_multi"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.44"
      },
      {
        "model": "ac7",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011116"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41552"
      }
    ]
  },
  "cve": "CVE-2023-41552",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-41552",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-41552",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-41552",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-41552",
            "trust": 0.8,
            "value": "Critical"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011116"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41552"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware and AC7 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-41552"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011116"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-41552",
        "trust": 2.6
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011116",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011116"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41552"
      }
    ]
  },
  "id": "VAR-202308-3958",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.43844455
  },
  "last_update_date": "2024-08-14T15:31:52.716000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011116"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41552"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/peris-navince/founded-0-days/blob/main/form_fast_setting_wifi_set/1.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-41552"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011116"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41552"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011116"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41552"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-12-12T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-011116"
      },
      {
        "date": "2023-08-30T13:15:13.087000",
        "db": "NVD",
        "id": "CVE-2023-41552"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-12-12T06:21:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-011116"
      },
      {
        "date": "2023-08-31T18:41:03.667000",
        "db": "NVD",
        "id": "CVE-2023-41552"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 firmware and \u00a0AC7\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011116"
      }
    ],
    "trust": 0.8
  }
}

var-201810-0278
Vulnerability from variot

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'ntpServer' parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. A buffer overflow vulnerability exists in httpd in several Tenda products that an attacker can exploit to cause a denial of service (the return address of the override function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0278",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 1.8,
        "vendor": "tenda",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.8,
        "vendor": "tenda",
        "version": "15.03.05.19_cn"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 1.8,
        "vendor": "tenda",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac7 v15.03.06.44 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10 v15.03.06.23 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac15 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01883"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013979"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18732"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac10_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac7_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013979"
      }
    ]
  },
  "cve": "CVE-2018-18732",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-18732",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-01883",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-129321",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-18732",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-18732",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-18732",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-01883",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201810-1359",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-129321",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01883"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129321"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013979"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1359"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18732"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027ntpServer\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. TendaAC7 and others are wireless router products of Tenda. Httpd is one of the HTTP server components. A buffer overflow vulnerability exists in httpd in several Tenda products that an attacker can exploit to cause a denial of service (the return address of the override function). The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-18732"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013979"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-01883"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129321"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-18732",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013979",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1359",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-01883",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-129321",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01883"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129321"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013979"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1359"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18732"
      }
    ]
  },
  "id": "VAR-201810-0278",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01883"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129321"
      }
    ],
    "trust": 1.4236169144444446
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01883"
      }
    ]
  },
  "last_update_date": "2024-11-23T23:04:57.538000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013979"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-129321"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013979"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18732"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://github.com/zillr0/routers/blob/master/tenda/stack2.md"
      },
      {
        "trust": 1.4,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18732"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18732"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01883"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129321"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013979"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1359"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18732"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-01883"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129321"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013979"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1359"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18732"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-01883"
      },
      {
        "date": "2018-10-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129321"
      },
      {
        "date": "2019-03-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-013979"
      },
      {
        "date": "2018-10-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1359"
      },
      {
        "date": "2018-10-29T12:29:07.960000",
        "db": "NVD",
        "id": "CVE-2018-18732"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-01883"
      },
      {
        "date": "2019-01-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129321"
      },
      {
        "date": "2019-03-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-013979"
      },
      {
        "date": "2019-04-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1359"
      },
      {
        "date": "2024-11-21T03:56:28.703000",
        "db": "NVD",
        "id": "CVE-2018-18732"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1359"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Product buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-013979"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1359"
      }
    ],
    "trust": 0.6
  }
}

var-202308-4199
Vulnerability from variot

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware, AC7 firmware, AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202308-4199",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac5",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.28"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.42_multi"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.44"
      },
      {
        "model": "ac7",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac5",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011500"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41562"
      }
    ]
  },
  "cve": "CVE-2023-41562",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-41562",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-41562",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-41562",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-41562",
            "trust": 0.8,
            "value": "Critical"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011500"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41562"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware, AC7 firmware, AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-41562"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011500"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-41562",
        "trust": 2.6
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011500",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011500"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41562"
      }
    ]
  },
  "id": "VAR-202308-4199",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.43844455
  },
  "last_update_date": "2024-08-14T14:36:40.968000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011500"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41562"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/peris-navince/founded-0-days/blob/main/setsmartpowermanagement/1.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-41562"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011500"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41562"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011500"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-41562"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-12-13T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-011500"
      },
      {
        "date": "2023-08-30T13:15:14.573000",
        "db": "NVD",
        "id": "CVE-2023-41562"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-12-13T07:03:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-011500"
      },
      {
        "date": "2023-09-01T20:04:12.327000",
        "db": "NVD",
        "id": "CVE-2023-41562"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-011500"
      }
    ],
    "trust": 0.8
  }
}

var-201810-0246
Vulnerability from variot

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "firewallEn" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. The AC series is a router product from Tenda. httpd is one of the HTTP server components. The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0246",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.05.19_cn"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "tenda",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac7 v15.03.06.44 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10 v15.03.06.23 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac15 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18 v15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09142"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011968"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1340"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18709"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tenda:ac10_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac7_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tenda:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011968"
      }
    ]
  },
  "cve": "CVE-2018-18709",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-18709",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-09142",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-129295",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-18709",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-18709",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-18709",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-09142",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201810-1340",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-129295",
            "trust": 0.1,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2018-18709",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09142"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129295"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-18709"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011968"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1340"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18709"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"firewallEn\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function. plural Tenda The product contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. The AC series is a router product from Tenda. httpd is one of the HTTP server components. The following products and versions are affected: Tenda AC7 V15.03.06.44_CN; AC9 V15.03.05.19(6318)_CN; AC10 V15.03.06.23_CN; AC15 V15.03.05.19_CN; AC18 V15.03.05.19 (6318)_CN version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-18709"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011968"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-09142"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129295"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-18709"
      }
    ],
    "trust": 2.34
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-18709",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011968",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1340",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-09142",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-129295",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-18709",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09142"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129295"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-18709"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011968"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1340"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18709"
      }
    ]
  },
  "id": "VAR-201810-0246",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09142"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129295"
      }
    ],
    "trust": 1.4236169144444446
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS",
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09142"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:30:16.915000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011968"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-129295"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011968"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18709"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.6,
        "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/tenda.md"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18709"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18709"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/119.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09142"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129295"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-18709"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011968"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1340"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18709"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-09142"
      },
      {
        "db": "VULHUB",
        "id": "VHN-129295"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-18709"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011968"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1340"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-18709"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-04-04T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-09142"
      },
      {
        "date": "2018-10-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129295"
      },
      {
        "date": "2018-10-29T00:00:00",
        "db": "VULMON",
        "id": "CVE-2018-18709"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011968"
      },
      {
        "date": "2018-10-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1340"
      },
      {
        "date": "2018-10-29T12:29:05.727000",
        "db": "NVD",
        "id": "CVE-2018-18709"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-04-04T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-09142"
      },
      {
        "date": "2018-12-14T00:00:00",
        "db": "VULHUB",
        "id": "VHN-129295"
      },
      {
        "date": "2018-12-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2018-18709"
      },
      {
        "date": "2019-01-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011968"
      },
      {
        "date": "2018-10-31T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-1340"
      },
      {
        "date": "2024-11-21T03:56:25.177000",
        "db": "NVD",
        "id": "CVE-2018-18709"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1340"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Product buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011968"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer overflow",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-1340"
      }
    ],
    "trust": 0.6
  }
}

var-201809-0930
Vulnerability from variot

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server. While processing the ssid parameter for a POST request, the value is directly used in a sprintf call to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow. plural Tenda Product Contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. Tenda AC7, etc. are all wireless router products of China Tenda. An attacker can use this vulnerability to cause a denial of service. The following products and versions are affected: Tenda AC7 15.03.06.44_CN Version; AC9 15.03.05.19(6318)_CN Version; AC10 15.03.06.23_CN Version; AC15 15.03.05.19_CN Version; AC18 15.03.05.19(6318)_CN Version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201809-0930",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tendacn",
        "version": "15.03.06.23"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tendacn",
        "version": "15.03.05.19"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tendacn",
        "version": "15.03.05.19"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tendacn",
        "version": "15.03.06.44"
      },
      {
        "model": "ac18",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "15.03.05.19"
      },
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.06.23_cn"
      },
      {
        "model": "ac15",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19_cn"
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.06.44_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "15.03.05.19(6318)_cn"
      },
      {
        "model": "ac9 15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac7 15.03.06.44 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10 15.03.06.23 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac15 15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18 15.03.05.19 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tendacn",
        "version": "15.03.05.19"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35175"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009403"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-036"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16333"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:tendacn:ac10_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac15_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac18_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac7_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:tendacn:ac9_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009403"
      }
    ]
  },
  "cve": "CVE-2018-16333",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-16333",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2020-35175",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-126682",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-16333",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-16333",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-16333",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2020-35175",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201809-036",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-126682",
            "trust": 0.1,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2018-16333",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35175"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126682"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-16333"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009403"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-036"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16333"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server. While processing the ssid parameter for a POST request, the value is directly used in a sprintf call to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow. plural Tenda Product Contains a buffer error vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. Tenda AC7, etc. are all wireless router products of China Tenda. An attacker can use this vulnerability to cause a denial of service. The following products and versions are affected: Tenda AC7 15.03.06.44_CN Version; AC9 15.03.05.19(6318)_CN Version; AC10 15.03.06.23_CN Version; AC15 15.03.05.19_CN Version; AC18 15.03.05.19(6318)_CN Version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-16333"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009403"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-35175"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126682"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-16333"
      }
    ],
    "trust": 2.34
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-16333",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009403",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-036",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-35175",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-126682",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-16333",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35175"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126682"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-16333"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009403"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-036"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16333"
      }
    ]
  },
  "id": "VAR-201809-0930",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35175"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126682"
      }
    ],
    "trust": 1.4236169144444446
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35175"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:38:03.789000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.tenda.com.cn/"
      },
      {
        "title": "",
        "trust": 0.1,
        "url": "https://github.com/kal1x/iotvulhub "
      },
      {
        "title": "Routers",
        "trust": 0.1,
        "url": "https://github.com/ZIllR0/Routers "
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2018-16333"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009403"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-126682"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009403"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16333"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.6,
        "url": "https://github.com/zillr0/routers/blob/master/tenda/oob1.md"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-16333"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-16333"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/119.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/kal1x/iotvulhub"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/zillr0/routers"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35175"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126682"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-16333"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009403"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-036"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16333"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-35175"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126682"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-16333"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009403"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-036"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16333"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-30T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-35175"
      },
      {
        "date": "2018-09-02T00:00:00",
        "db": "VULHUB",
        "id": "VHN-126682"
      },
      {
        "date": "2018-09-02T00:00:00",
        "db": "VULMON",
        "id": "CVE-2018-16333"
      },
      {
        "date": "2018-11-19T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-009403"
      },
      {
        "date": "2018-09-03T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201809-036"
      },
      {
        "date": "2018-09-02T03:29:00.620000",
        "db": "NVD",
        "id": "CVE-2018-16333"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-30T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-35175"
      },
      {
        "date": "2018-10-25T00:00:00",
        "db": "VULHUB",
        "id": "VHN-126682"
      },
      {
        "date": "2018-10-25T00:00:00",
        "db": "VULMON",
        "id": "CVE-2018-16333"
      },
      {
        "date": "2018-11-19T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-009403"
      },
      {
        "date": "2018-09-03T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201809-036"
      },
      {
        "date": "2024-11-21T03:52:32.530000",
        "db": "NVD",
        "id": "CVE-2018-16333"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-036"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Tenda Product buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009403"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer overflow",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-036"
      }
    ],
    "trust": 0.6
  }
}

var-202203-1214
Vulnerability from variot

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetVirtualServerCfg function. The Tenda AC9 is a wireless router from the Chinese company Tenda.

There is a buffer overflow vulnerability in Tenda AC9 version 15.03.2.21. The vulnerability arises from the fact that when the list parameter in the SetVirtualServerCfg function performs operations on memory, the data boundary is not properly verified. An attacker can exploit this vulnerability to cause arbitrary command execution

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202203-1214",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.2.21"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v15.03.2.21"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26242"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25437"
      }
    ]
  },
  "cve": "CVE-2022-25437",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-25437",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-26242",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-25437",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-25437",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-26242",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202203-1851",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26242"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1851"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25437"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetVirtualServerCfg function. The Tenda AC9 is a wireless router from the Chinese company Tenda. \n\r\n\r\nThere is a buffer overflow vulnerability in Tenda AC9 version 15.03.2.21. The vulnerability arises from the fact that when the list parameter in the SetVirtualServerCfg function performs operations on memory, the data boundary is not properly verified. An attacker can exploit this vulnerability to cause arbitrary command execution",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25437"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-26242"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-25437",
        "trust": 2.2
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-26242",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1851",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26242"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1851"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25437"
      }
    ]
  },
  "id": "VAR-202203-1214",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26242"
      }
    ],
    "trust": 1.03844455
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26242"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:50:51.383000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC9 Buffer Overflow Vulnerability (CNVD-2022-26242)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/328731"
      },
      {
        "title": "Tenda AC9 Fixes for command injection vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=186932"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26242"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1851"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25437"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.2,
        "url": "https://github.com/ephaha/iot_vuln/tree/main/tenda/ac9/9"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-25437/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26242"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1851"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25437"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26242"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1851"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25437"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-06T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-26242"
      },
      {
        "date": "2022-03-18T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1851"
      },
      {
        "date": "2022-03-18T21:15:08.170000",
        "db": "NVD",
        "id": "CVE-2022-25437"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-06T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-26242"
      },
      {
        "date": "2022-03-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1851"
      },
      {
        "date": "2024-11-21T06:52:10.937000",
        "db": "NVD",
        "id": "CVE-2022-25437"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1851"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 Buffer Overflow Vulnerability (CNVD-2022-26242)",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-26242"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "command injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1851"
      }
    ],
    "trust": 0.6
  }
}

var-202208-1285
Vulnerability from variot

Tenda AC9 V15.03.2.21_cn is vulnerable to command injection via goform/SetSysTimeCfg. Shenzhen Tenda Technology Co.,Ltd. of AC9 The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202208-1285",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.2.21_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac9  firmware  15.03.2.21 cn"
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9 v15.03.2.21 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75820"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014732"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36273"
      }
    ]
  },
  "cve": "CVE-2022-36273",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-75820",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-36273",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-36273",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-36273",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-36273",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-75820",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202208-3136",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75820"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014732"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3136"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36273"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 V15.03.2.21_cn is vulnerable to command injection via goform/SetSysTimeCfg. Shenzhen Tenda Technology Co.,Ltd. of AC9 The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-36273"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014732"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-75820"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-36273",
        "trust": 3.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014732",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-75820",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3136",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75820"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014732"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3136"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36273"
      }
    ]
  },
  "id": "VAR-202208-1285",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75820"
      }
    ],
    "trust": 1.319222275
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75820"
      }
    ]
  },
  "last_update_date": "2024-08-14T14:17:44.781000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-78",
        "trust": 1.0
      },
      {
        "problemtype": "OS Command injection (CWE-78) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014732"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36273"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/f0und-icu/cveids/tree/main/tendaac9"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-36273"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-36273/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75820"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014732"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3136"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36273"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75820"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014732"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3136"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36273"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-11-10T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-75820"
      },
      {
        "date": "2023-09-21T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-014732"
      },
      {
        "date": "2022-08-16T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202208-3136"
      },
      {
        "date": "2022-08-16T13:15:11.457000",
        "db": "NVD",
        "id": "CVE-2022-36273"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-11-10T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-75820"
      },
      {
        "date": "2023-09-21T08:08:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-014732"
      },
      {
        "date": "2022-08-18T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202208-3136"
      },
      {
        "date": "2023-08-08T14:21:49.707000",
        "db": "NVD",
        "id": "CVE-2022-36273"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3136"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 in the firmware \u00a0OS\u00a0 Command injection vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014732"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "command injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3136"
      }
    ],
    "trust": 0.6
  }
}

var-202202-0846
Vulnerability from variot

Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the parameter NPTR. Tenda AC9 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC9 is a wireless router from the Chinese company Tenda. An attacker could exploit this vulnerability to cause a buffer overflow

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202202-0846",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "v15.03.2.21_cn"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac9  firmware  15.03.2.21_cn"
      },
      {
        "model": "ac9 v15.03.2.21 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-22750"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006076"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25414"
      }
    ]
  },
  "cve": "CVE-2022-25414",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-25414",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-22750",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2022-25414",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-25414",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-25414",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-25414",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-22750",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202202-1830",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-22750"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006076"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1830"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25414"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the parameter NPTR. Tenda AC9 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC9 is a wireless router from the Chinese company Tenda. An attacker could exploit this vulnerability to cause a buffer overflow",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25414"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006076"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-22750"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-25414",
        "trust": 3.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006076",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-22750",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1830",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-22750"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006076"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1830"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25414"
      }
    ]
  },
  "id": "VAR-202202-0846",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-22750"
      }
    ],
    "trust": 1.319222275
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-22750"
      }
    ]
  },
  "last_update_date": "2024-11-23T23:00:58.053000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top\u00a0Page",
        "trust": 0.8,
        "url": "https://www.tendacn.com/default.html"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006076"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006076"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25414"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/ephaha/iot_vuln/tree/main/tenda/ac9/1"
      },
      {
        "trust": 2.0,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-25414"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-25414/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-22750"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006076"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1830"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25414"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-22750"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006076"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1830"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25414"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-03-25T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-22750"
      },
      {
        "date": "2023-06-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-006076"
      },
      {
        "date": "2022-02-24T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202202-1830"
      },
      {
        "date": "2022-02-24T15:15:31.860000",
        "db": "NVD",
        "id": "CVE-2022-25414"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-03-25T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-22750"
      },
      {
        "date": "2023-06-28T09:07:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-006076"
      },
      {
        "date": "2022-03-04T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202202-1830"
      },
      {
        "date": "2024-11-21T06:52:09.483000",
        "db": "NVD",
        "id": "CVE-2022-25414"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1830"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0AC9\u00a0 Out-of-bounds write vulnerability in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-006076"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202202-1830"
      }
    ],
    "trust": 0.6
  }
}

var-202105-1657
Vulnerability from variot

There is a buffer overflow vulnerability in the Web server httpd of the router in Tenda router devices such as Tenda AC9 V1.0 V15.03.02.19(6318) and Tenda AC9 V3.0 V15.03.06.42_multi. When setting the virtual service, the httpd program will crash and exit when the super-long list parameter occurs. Shenzhen Tenda Technology Co.,Ltd. of AC9 A buffer error vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. AC9 is a 1200M 11AC wireless router with Gigabit Ethernet port launched by Shenzhen Jixiang Tengda Technology Co., Ltd. in 2016.

Tenda AC9 has a denial of service vulnerability, which can be exploited by attackers to cause the program to crash

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202105-1657",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.42_multi"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.05.19\\(6318\\)"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac9  firmware  15.03.05.19(6318)"
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac9  firmware  15.03.06.42 multi"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v1.0v15.03.05.19(6318)"
      },
      {
        "model": "ac9 v15.03.06.42 multi",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v3.0"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-24948"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-019681"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-42659"
      }
    ]
  },
  "cve": "CVE-2021-42659",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "CVE-2021-42659",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "CNVD-2021-24948",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "id": "CVE-2021-42659",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Adjacent Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 6.5,
            "baseSeverity": "Medium",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2021-42659",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2021-42659",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2021-42659",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-24948",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202205-4013",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-24948"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-019681"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4013"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-42659"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "There is a buffer overflow vulnerability in the Web server httpd of the router in Tenda router devices such as Tenda AC9 V1.0 V15.03.02.19(6318) and Tenda AC9 V3.0 V15.03.06.42_multi. When setting the virtual service, the httpd program will crash and exit when the super-long list parameter occurs. Shenzhen Tenda Technology Co.,Ltd. of AC9 A buffer error vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state. AC9 is a 1200M 11AC wireless router with Gigabit Ethernet port launched by Shenzhen Jixiang Tengda Technology Co., Ltd. in 2016. \n\r\n\r\nTenda AC9 has a denial of service vulnerability, which can be exploited by attackers to cause the program to crash",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-42659"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-019681"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-24948"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-42659",
        "trust": 3.2
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-24948",
        "trust": 3.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-019681",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4013",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-24948"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-019681"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4013"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-42659"
      }
    ]
  },
  "id": "VAR-202105-1657",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-24948"
      }
    ],
    "trust": 1.319222275
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-24948"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:57:56.886000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Tenda AC9 Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=199829"
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4013"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.0
      },
      {
        "problemtype": "Buffer error (CWE-119) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-019681"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-42659"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/lyc-heng/routers/blob/main/routers/stack4.md"
      },
      {
        "trust": 2.4,
        "url": "https://www.cnvd.org.cn/flaw/show/cnvd-2021-24948"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-42659"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2021-42659/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-019681"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4013"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-42659"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-24948"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-019681"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4013"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-42659"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-05-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-24948"
      },
      {
        "date": "2023-08-10T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-019681"
      },
      {
        "date": "2022-05-24T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202205-4013"
      },
      {
        "date": "2022-05-24T12:15:07.590000",
        "db": "NVD",
        "id": "CVE-2021-42659"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-04-06T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-24948"
      },
      {
        "date": "2023-08-10T08:27:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-019681"
      },
      {
        "date": "2022-07-14T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202205-4013"
      },
      {
        "date": "2024-11-21T06:27:55.827000",
        "db": "NVD",
        "id": "CVE-2021-42659"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote or local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4013"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 Buffer error vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-019681"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202205-4013"
      }
    ],
    "trust": 0.6
  }
}

var-202308-3714
Vulnerability from variot

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. AC10 firmware, ac1206 firmware, AC6 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202308-3714",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac5",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.28"
      },
      {
        "model": "ac9",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.42_multi"
      },
      {
        "model": "fh1205",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "2.0.0.7\\(775\\)"
      },
      {
        "model": "ac1206",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.23"
      },
      {
        "model": "ac10",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.23"
      },
      {
        "model": "ac7",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.44"
      },
      {
        "model": "ac6",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "15.03.06.23"
      },
      {
        "model": "f1203",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "2.0.1.6"
      },
      {
        "model": "fh1203",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "2.0.1.6"
      },
      {
        "model": "ac1206",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "fh1203",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac6",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac10",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac9",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac5",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "fh1205",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "f1203",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac7",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021659"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38936"
      }
    ]
  },
  "cve": "CVE-2023-38936",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-38936",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-38936",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-38936",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-38936",
            "trust": 0.8,
            "value": "Critical"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021659"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38936"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. AC10 firmware, ac1206 firmware, AC6 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-38936"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021659"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-38936",
        "trust": 2.6
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021659",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021659"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38936"
      }
    ]
  },
  "id": "VAR-202308-3714",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.3288697725
  },
  "last_update_date": "2024-08-14T15:36:47.021000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021659"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38936"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/formsetspeedwan/readme.md"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-38936"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021659"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38936"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021659"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38936"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-01-19T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-021659"
      },
      {
        "date": "2023-08-07T19:15:11.343000",
        "db": "NVD",
        "id": "CVE-2023-38936"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-01-19T07:51:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-021659"
      },
      {
        "date": "2023-08-10T18:20:51.897000",
        "db": "NVD",
        "id": "CVE-2023-38936"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021659"
      }
    ],
    "trust": 0.8
  }
}

CVE-2018-18730 (GCVE-0-2018-18730)
Vulnerability from cvelistv5
Published
2018-10-28 00:00
Modified
2024-08-05 11:16
Severity ?
CWE
  • n/a
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'startIp' and 'endIp' parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:16:00.429Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-10-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027startIp\u0027 and \u0027endIp\u0027 parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-28T00:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-18730",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027startIp\u0027 and \u0027endIp\u0027 parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md",
              "refsource": "MISC",
              "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-18730",
    "datePublished": "2018-10-28T00:00:00",
    "dateReserved": "2018-10-27T00:00:00",
    "dateUpdated": "2024-08-05T11:16:00.429Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-38935 (GCVE-0-2023-38935)
Vulnerability from cvelistv5
Published
2023-08-07 00:00
Modified
2024-10-15 20:07
Severity ?
CWE
  • n/a
Summary
Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:54:39.522Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetQosBand/README.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac1206",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V15.03.06.23"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac8",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V4 V16.03.34.06"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac5",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V1.0 V15.03.06.28"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "v4.0 V16.03.10.13"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac9",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V3.0 V15.03.06.42_multi"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-38935",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-15T20:06:05.688360Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-15T20:07:56.040Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-07T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetQosBand/README.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-38935",
    "datePublished": "2023-08-07T00:00:00",
    "dateReserved": "2023-07-25T00:00:00",
    "dateUpdated": "2024-10-15T20:07:56.040Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-14559 (GCVE-0-2018-14559)
Vulnerability from cvelistv5
Published
2019-04-25 19:44
Modified
2024-08-05 09:29
Severity ?
CWE
  • n/a
Summary
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router's web server (httpd). When processing the list parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T09:29:51.666Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-02/Tenda.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router\u0027s web server (httpd). When processing the list parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-04-25T19:44:46",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-02/Tenda.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-14559",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router\u0027s web server (httpd). When processing the list parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-02/Tenda.md",
              "refsource": "MISC",
              "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-02/Tenda.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-14559",
    "datePublished": "2019-04-25T19:44:46",
    "dateReserved": "2018-07-23T00:00:00",
    "dateUpdated": "2024-08-05T09:29:51.666Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25431 (GCVE-0-2022-25431)
Vulnerability from cvelistv5
Published
2022-03-18 20:53
Modified
2024-08-03 04:42
Severity ?
CWE
  • n/a
Summary
Tenda AC9 v15.03.2.21 was discovered to contain multiple stack overflows via the NPTR, V12, V10 and V11 parameter in the Formsetqosband function.
References
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:42:49.384Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/4"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 v15.03.2.21 was discovered to contain multiple stack overflows via the NPTR, V12, V10 and V11 parameter in the Formsetqosband function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-18T20:53:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/4"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-25431",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC9 v15.03.2.21 was discovered to contain multiple stack overflows via the NPTR, V12, V10 and V11 parameter in the Formsetqosband function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/4",
              "refsource": "MISC",
              "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/4"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-25431",
    "datePublished": "2022-03-18T20:53:01",
    "dateReserved": "2022-02-21T00:00:00",
    "dateUpdated": "2024-08-03T04:42:49.384Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-9731 (GCVE-0-2025-9731)
Vulnerability from cvelistv5
Published
2025-08-31 13:32
Modified
2025-08-31 13:32
CWE
  • CWE-798 - Hard-coded Credentials
  • CWE-259 - Use of Hard-coded Password
Summary
A vulnerability was determined in Tenda AC9 15.03.05.19. The impacted element is an unknown function of the file /etc_ro/shadow of the component Administrative Interface. This manipulation causes hard-coded credentials. It is possible to launch the attack on the local host. The attack's complexity is rated as high. The exploitability is regarded as difficult. The exploit has been publicly disclosed and may be utilized.
Impacted products
Vendor Product Version
Tenda AC9 Version: 15.03.05.19
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "cna": {
      "affected": [
        {
          "modules": [
            "Administrative Interface"
          ],
          "product": "AC9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.05.19"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Yu_Bao (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was determined in Tenda AC9 15.03.05.19. The impacted element is an unknown function of the file /etc_ro/shadow of the component Administrative Interface. This manipulation causes hard-coded credentials. It is possible to launch the attack on the local host. The attack\u0027s complexity is rated as high. The exploitability is regarded as difficult. The exploit has been publicly disclosed and may be utilized."
        },
        {
          "lang": "de",
          "value": "In Tenda AC9 15.03.05.19 wurde eine Schwachstelle gefunden. Dies betrifft einen unbekannten Teil der Datei /etc_ro/shadow der Komponente Administrative Interface. Durch Manipulieren mit unbekannten Daten kann eine hard-coded credentials-Schwachstelle ausgenutzt werden. Der Angriff ist nur lokal m\u00f6glich. Ein Angriff erfordert eine vergleichsweise hohe Komplexit\u00e4t. Die Ausnutzbarkeit gilt als schwierig. Die Schwachstelle wurde \u00f6ffentlich offengelegt und k\u00f6nnte ausgenutzt werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 2,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 2.5,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 2.5,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 1,
            "vectorString": "AV:L/AC:H/Au:S/C:P/I:N/A:N/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-259",
              "description": "Use of Hard-coded Password",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-31T13:32:07.821Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-322022 | Tenda AC9 Administrative shadow hard-coded credentials",
          "tags": [
            "vdb-entry"
          ],
          "url": "https://vuldb.com/?id.322022"
        },
        {
          "name": "VDB-322022 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.322022"
        },
        {
          "name": "Submit #639748 | Tenda AC9 V15.03.05.19 Hard-coded Credentials",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.639748"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/August829/Yu/blob/main/58ead8e7e08bfb0e4.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-08-30T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-08-30T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-08-30T16:03:04.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC9 Administrative shadow hard-coded credentials"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-9731",
    "datePublished": "2025-08-31T13:32:07.821Z",
    "dateReserved": "2025-08-30T13:58:00.879Z",
    "dateUpdated": "2025-08-31T13:32:07.821Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-41561 (GCVE-0-2023-41561)
Vulnerability from cvelistv5
Published
2023-08-30 00:00
Modified
2024-10-01 19:00
Severity ?
CWE
  • n/a
Summary
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T19:01:35.314Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/peris-navince/founded-0-days/blob/main/formSetPPTPServer/1.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac9",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "3.0_v15.03.06.42_multi"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac5",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "us_ac5v1.0rtl_v15.03.06.28"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-41561",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-01T18:56:47.271577Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-01T19:00:27.519Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-30T12:37:22.259883",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/peris-navince/founded-0-days/blob/main/formSetPPTPServer/1.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-41561",
    "datePublished": "2023-08-30T00:00:00",
    "dateReserved": "2023-08-30T00:00:00",
    "dateUpdated": "2024-10-01T19:00:27.519Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-42634 (GCVE-0-2024-42634)
Vulnerability from cvelistv5
Published
2024-08-16 00:00
Modified
2024-08-16 17:49
Severity ?
CWE
  • n/a
Summary
A Command Injection vulnerability exists in formWriteFacMac of the httpd binary in Tenda AC9 v15.03.06.42. As a result, attacker can execute OS commands with root privileges.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac9",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "v15.03.06.42"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-42634",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-16T17:41:34.441654Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-94",
                "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-16T17:49:14.024Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A Command Injection vulnerability exists in formWriteFacMac of the httpd binary in Tenda AC9 v15.03.06.42. As a result, attacker can execute OS commands with root privileges."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-16T15:55:16.530062",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/goldds96/Report/blob/main/Tenda/AC9/CI.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-42634",
    "datePublished": "2024-08-16T00:00:00",
    "dateReserved": "2024-08-05T00:00:00",
    "dateUpdated": "2024-08-16T17:49:14.024Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-28560 (GCVE-0-2022-28560)
Vulnerability from cvelistv5
Published
2022-05-03 15:20
Modified
2024-08-03 05:56
Severity ?
CWE
  • n/a
Summary
There is a stack overflow vulnerability in the goform/fast_setting_wifi_set function in the httpd service of Tenda ac9 15.03.2.21_cn router. An attacker can obtain a stable shell through a carefully constructed payload
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:56:15.615Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/iot-firmeware/-Router-vulnerability/tree/main/Tenda%20AC9"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "There is a stack overflow vulnerability in the goform/fast_setting_wifi_set function in the httpd service of Tenda ac9 15.03.2.21_cn router. An attacker can obtain a stable shell through a carefully constructed payload"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-03T15:20:33",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/iot-firmeware/-Router-vulnerability/tree/main/Tenda%20AC9"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-28560",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "There is a stack overflow vulnerability in the goform/fast_setting_wifi_set function in the httpd service of Tenda ac9 15.03.2.21_cn router. An attacker can obtain a stable shell through a carefully constructed payload"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/iot-firmeware/-Router-vulnerability/tree/main/Tenda%20AC9",
              "refsource": "MISC",
              "url": "https://github.com/iot-firmeware/-Router-vulnerability/tree/main/Tenda%20AC9"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-28560",
    "datePublished": "2022-05-03T15:20:33",
    "dateReserved": "2022-04-04T00:00:00",
    "dateUpdated": "2024-08-03T05:56:15.615Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-18729 (GCVE-0-2018-18729)
Vulnerability from cvelistv5
Published
2018-10-28 00:00
Modified
2024-08-05 11:16
Severity ?
CWE
  • n/a
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router's web server -- httpd. While processing the 'mac' parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:16:00.404Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-10-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027mac\u0027 parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-28T00:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-18729",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027mac\u0027 parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md",
              "refsource": "MISC",
              "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-18729",
    "datePublished": "2018-10-28T00:00:00",
    "dateReserved": "2018-10-27T00:00:00",
    "dateUpdated": "2024-08-05T11:16:00.404Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-18708 (GCVE-0-2018-18708)
Vulnerability from cvelistv5
Published
2018-10-27 22:00
Modified
2024-08-05 11:16
Severity ?
CWE
  • n/a
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromAddressNat" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:16:00.428Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-10-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromAddressNat\" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-27T22:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-18708",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromAddressNat\" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md",
              "refsource": "MISC",
              "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-18708",
    "datePublished": "2018-10-27T22:00:00",
    "dateReserved": "2018-10-27T00:00:00",
    "dateUpdated": "2024-08-05T11:16:00.428Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25428 (GCVE-0-2022-25428)
Vulnerability from cvelistv5
Published
2022-03-18 20:53
Modified
2024-08-03 04:42
Severity ?
CWE
  • n/a
Summary
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the deviceId parameter in the saveparentcontrolinfo function.
References
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:42:49.975Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/3"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the deviceId parameter in the saveparentcontrolinfo function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-18T20:53:02",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/3"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-25428",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the deviceId parameter in the saveparentcontrolinfo function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/3",
              "refsource": "MISC",
              "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/3"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-25428",
    "datePublished": "2022-03-18T20:53:02",
    "dateReserved": "2022-02-21T00:00:00",
    "dateUpdated": "2024-08-03T04:42:49.975Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-16923 (GCVE-0-2017-16923)
Vulnerability from cvelistv5
Published
2017-11-21 14:00
Modified
2024-09-17 03:14
Severity ?
CWE
  • n/a
Summary
Command Injection vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to execute arbitrary OS commands via a crafted cgi-bin/luci/usbeject?dev_name= GET request from the LAN. This occurs because the "sub_A6E8 usbeject_process_entry" function executes a system function with untrusted input.
References
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T20:35:21.360Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Iolop/Poc/tree/master/Router/Tenda"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Command Injection vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to execute arbitrary OS commands via a crafted cgi-bin/luci/usbeject?dev_name= GET request from the LAN. This occurs because the \"sub_A6E8 usbeject_process_entry\" function executes a system function with untrusted input."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-11-21T14:00:00Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Iolop/Poc/tree/master/Router/Tenda"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2017-16923",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Command Injection vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to execute arbitrary OS commands via a crafted cgi-bin/luci/usbeject?dev_name= GET request from the LAN. This occurs because the \"sub_A6E8 usbeject_process_entry\" function executes a system function with untrusted input."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/Iolop/Poc/tree/master/Router/Tenda",
              "refsource": "MISC",
              "url": "https://github.com/Iolop/Poc/tree/master/Router/Tenda"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2017-16923",
    "datePublished": "2017-11-21T14:00:00Z",
    "dateReserved": "2017-11-21T00:00:00Z",
    "dateUpdated": "2024-09-17T03:14:10.141Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-45427 (GCVE-0-2025-45427)
Vulnerability from cvelistv5
Published
2025-04-23 00:00
Modified
2025-04-23 15:18
Severity ?
CWE
  • n/a
Summary
In Tenda AC9 v1.0 with firmware V15.03.05.14_multi, the security parameter of /goform/WifiBasicSet has a stack overflow vulnerability, which can lead to remote arbitrary code execution.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-45427",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-23T15:17:52.934074Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-23T15:18:49.042Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/shuqi233/loophole/blob/main/Tenda%20AC9/WifiBasicSet-security.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Tenda AC9 v1.0 with firmware V15.03.05.14_multi, the security parameter of /goform/WifiBasicSet has a stack overflow vulnerability, which can lead to remote arbitrary code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-23T14:59:35.102Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/shuqi233/loophole/blob/main/Tenda%20AC9/WifiBasicSet-security.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-45427",
    "datePublished": "2025-04-23T00:00:00.000Z",
    "dateReserved": "2025-04-22T00:00:00.000Z",
    "dateUpdated": "2025-04-23T15:18:49.042Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-18732 (GCVE-0-2018-18732)
Vulnerability from cvelistv5
Published
2018-10-28 00:00
Modified
2024-08-05 11:16
Severity ?
CWE
  • n/a
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'ntpServer' parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:16:00.422Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-10-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027ntpServer\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-28T00:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-18732",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027ntpServer\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md",
              "refsource": "MISC",
              "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-18732",
    "datePublished": "2018-10-28T00:00:00",
    "dateReserved": "2018-10-27T00:00:00",
    "dateUpdated": "2024-08-05T11:16:00.422Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25418 (GCVE-0-2022-25418)
Vulnerability from cvelistv5
Published
2022-02-22 22:44
Modified
2024-08-03 04:42
Severity ?
CWE
  • n/a
Summary
Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function openSchedWifi.
References
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:42:48.952Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/2"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function openSchedWifi."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-02-22T22:44:17",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/2"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-25418",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function openSchedWifi."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/2",
              "refsource": "MISC",
              "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/2"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-25418",
    "datePublished": "2022-02-22T22:44:17",
    "dateReserved": "2022-02-21T00:00:00",
    "dateUpdated": "2024-08-03T04:42:48.952Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-38823 (GCVE-0-2023-38823)
Vulnerability from cvelistv5
Published
2023-11-20 00:00
Modified
2025-06-10 13:53
Severity ?
CWE
  • n/a
Summary
Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:54:38.461Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/johnathanhuutri/CVE_report/blob/master/CVE-2023-38823/README.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2023-38823",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-10T13:52:20.042124Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-120",
                "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-10T13:53:51.181Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-29T21:24:20.736Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/johnathanhuutri/CVE_report/blob/master/CVE-2023-38823/README.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-38823",
    "datePublished": "2023-11-20T00:00:00.000Z",
    "dateReserved": "2023-07-25T00:00:00.000Z",
    "dateUpdated": "2025-06-10T13:53:51.181Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-18731 (GCVE-0-2018-18731)
Vulnerability from cvelistv5
Published
2018-10-28 00:00
Modified
2024-08-05 11:16
Severity ?
CWE
  • n/a
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'deviceMac' parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:16:00.376Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-10-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceMac\u0027 parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-28T00:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-18731",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceMac\u0027 parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md",
              "refsource": "MISC",
              "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-18731",
    "datePublished": "2018-10-28T00:00:00",
    "dateReserved": "2018-10-27T00:00:00",
    "dateUpdated": "2024-08-05T11:16:00.376Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-14557 (GCVE-0-2018-14557)
Vulnerability from cvelistv5
Published
2019-04-25 19:42
Modified
2024-08-05 09:29
Severity ?
CWE
  • n/a
Summary
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router's web server (httpd). When processing the page parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, a causing buffer overflow.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T09:29:51.699Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-03/Tenda.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router\u0027s web server (httpd). When processing the page parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, a causing buffer overflow."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-04-25T19:42:41",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-03/Tenda.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-14557",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router\u0027s web server (httpd). When processing the page parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, a causing buffer overflow."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-03/Tenda.md",
              "refsource": "MISC",
              "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-03/Tenda.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-14557",
    "datePublished": "2019-04-25T19:42:41",
    "dateReserved": "2018-07-23T00:00:00",
    "dateUpdated": "2024-08-05T09:29:51.699Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-22946 (GCVE-0-2025-22946)
Vulnerability from cvelistv5
Published
2025-01-10 00:00
Modified
2025-01-14 14:53
Severity ?
CWE
  • n/a
Summary
Tenda ac9 v1.0 firmware v15.03.05.19 contains a stack overflow vulnerability in /goform/SetOnlineDevName, which may lead to remote arbitrary code execution.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-22946",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-14T14:52:26.619880Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-120",
                "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-14T14:53:30.405Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda ac9 v1.0 firmware v15.03.05.19 contains a stack overflow vulnerability in /goform/SetOnlineDevName, which may lead to remote arbitrary code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-10T15:11:59.431974",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://noisy-caravel-a9a.notion.site/Tenda_AC9V1-0_V15-03-05-19_formSetDeviceName_sprintf_bof-16f898c94eac8057afcbceb63fda7d24"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-22946",
    "datePublished": "2025-01-10T00:00:00",
    "dateReserved": "2025-01-09T00:00:00",
    "dateUpdated": "2025-01-14T14:53:30.405Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-36571 (GCVE-0-2022-36571)
Vulnerability from cvelistv5
Published
2022-08-31 19:03
Modified
2024-08-03 10:07
Severity ?
CWE
  • n/a
Summary
Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the mask parameter at /goform/WanParameterSetting.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:07:34.530Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/CyberUnicornIoT/IoTvuln/blob/main/Tenda_ac9/2/tenda_ac9_WanParameterSetting.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the mask parameter at /goform/WanParameterSetting."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-31T19:03:27",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/CyberUnicornIoT/IoTvuln/blob/main/Tenda_ac9/2/tenda_ac9_WanParameterSetting.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-36571",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the mask parameter at /goform/WanParameterSetting."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/CyberUnicornIoT/IoTvuln/blob/main/Tenda_ac9/2/tenda_ac9_WanParameterSetting.md",
              "refsource": "MISC",
              "url": "https://github.com/CyberUnicornIoT/IoTvuln/blob/main/Tenda_ac9/2/tenda_ac9_WanParameterSetting.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-36571",
    "datePublished": "2022-08-31T19:03:27",
    "dateReserved": "2022-07-25T00:00:00",
    "dateUpdated": "2024-08-03T10:07:34.530Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-41556 (GCVE-0-2023-41556)
Vulnerability from cvelistv5
Published
2023-08-30 00:00
Modified
2024-10-01 19:40
Severity ?
CWE
  • n/a
Summary
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T19:01:35.265Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetIpMacBind/1.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac7",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.0_v15.03.06.44"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac9",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "3.0_v15.03.06.42_multi"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac5",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.0rtl_v15.03.06.28"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-41556",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-01T19:38:05.672947Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-01T19:40:15.233Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-30T12:25:24.881206",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetIpMacBind/1.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-41556",
    "datePublished": "2023-08-30T00:00:00",
    "dateReserved": "2023-08-30T00:00:00",
    "dateUpdated": "2024-10-01T19:40:15.233Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-41562 (GCVE-0-2023-41562)
Vulnerability from cvelistv5
Published
2023-08-30 00:00
Modified
2024-10-01 18:55
Severity ?
CWE
  • n/a
Summary
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T19:01:35.185Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/peris-navince/founded-0-days/blob/main/setSmartPowerManagement/1.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac7",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.0_v15.03.06.44"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac9",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "3.0_v15.03.06.42_multi"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac5",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.0rtl_v15.03.06.28"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-41562",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-01T18:52:45.696202Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-01T18:55:00.806Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-30T12:17:16.245089",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/peris-navince/founded-0-days/blob/main/setSmartPowerManagement/1.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-41562",
    "datePublished": "2023-08-30T00:00:00",
    "dateReserved": "2023-08-30T00:00:00",
    "dateUpdated": "2024-10-01T18:55:00.806Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-18727 (GCVE-0-2018-18727)
Vulnerability from cvelistv5
Published
2018-10-28 00:00
Modified
2024-08-05 11:16
Severity ?
CWE
  • n/a
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'deviceList' parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:16:00.390Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-10-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceList\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-28T00:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-18727",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceList\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md",
              "refsource": "MISC",
              "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-18727",
    "datePublished": "2018-10-28T00:00:00",
    "dateReserved": "2018-10-27T00:00:00",
    "dateUpdated": "2024-08-05T11:16:00.390Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-27022 (GCVE-0-2022-27022)
Vulnerability from cvelistv5
Published
2022-04-07 15:02
Modified
2024-08-03 05:18
Severity ?
CWE
  • n/a
Summary
There is a stack overflow vulnerability in the SetSysTimeCfg() function in the httpd service of Tenda AC9 V15.03.2.21_cn. The attacker can obtain a stable root shell through a constructed payload.
References
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:18:39.262Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/14"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "There is a stack overflow vulnerability in the SetSysTimeCfg() function in the httpd service of Tenda AC9 V15.03.2.21_cn. The attacker can obtain a stable root shell through a constructed payload."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-07T15:02:46",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/14"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-27022",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "There is a stack overflow vulnerability in the SetSysTimeCfg() function in the httpd service of Tenda AC9 V15.03.2.21_cn. The attacker can obtain a stable root shell through a constructed payload."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/14",
              "refsource": "MISC",
              "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/14"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-27022",
    "datePublished": "2022-04-07T15:02:46",
    "dateReserved": "2022-03-14T00:00:00",
    "dateUpdated": "2024-08-03T05:18:39.262Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-29384 (GCVE-0-2025-29384)
Vulnerability from cvelistv5
Published
2025-03-14 00:00
Modified
2025-03-19 18:37
Severity ?
CWE
  • n/a
Summary
In Tenda AC9 v1.0 V15.03.05.14_multi, the wanMTU parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-29384",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-17T18:16:09.372316Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-787",
                "description": "CWE-787 Out-of-bounds Write",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-19T18:37:25.716Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Tenda AC9 v1.0 V15.03.05.14_multi, the wanMTU parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-14T17:04:42.367Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/shuqi233/loophole/blob/main/Tenda%20AC9/AdvSetMacMtuWan1.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-29384",
    "datePublished": "2025-03-14T00:00:00.000Z",
    "dateReserved": "2025-03-11T00:00:00.000Z",
    "dateUpdated": "2025-03-19T18:37:25.716Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-22949 (GCVE-0-2025-22949)
Vulnerability from cvelistv5
Published
2025-01-10 00:00
Modified
2025-01-14 14:51
Severity ?
CWE
  • n/a
Summary
Tenda ac9 v1.0 firmware v15.03.05.19 is vulnerable to command injection in /goform/SetSambaCfg, which may lead to remote arbitrary code execution.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-22949",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-14T14:50:21.905514Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-77",
                "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-14T14:51:26.573Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda ac9 v1.0 firmware v15.03.05.19 is vulnerable to command injection in /goform/SetSambaCfg, which may lead to remote arbitrary code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-10T15:13:10.849832",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://noisy-caravel-a9a.notion.site/Tenda_AC9V1-0_V15-03-05-19_formSetSambaConf_doSystemCmd_CI-16f898c94eac80d5801bdaf777ac2b27"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-22949",
    "datePublished": "2025-01-10T00:00:00",
    "dateReserved": "2025-01-09T00:00:00",
    "dateUpdated": "2025-01-14T14:51:26.573Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25417 (GCVE-0-2022-25417)
Vulnerability from cvelistv5
Published
2022-02-22 22:44
Modified
2024-08-03 04:42
Severity ?
CWE
  • n/a
Summary
Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function saveparentcontrolinfo.
References
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:42:49.926Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/3"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function saveparentcontrolinfo."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-02-22T22:44:16",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/3"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-25417",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function saveparentcontrolinfo."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/3",
              "refsource": "MISC",
              "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/3"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-25417",
    "datePublished": "2022-02-22T22:44:16",
    "dateReserved": "2022-02-21T00:00:00",
    "dateUpdated": "2024-08-03T04:42:49.926Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25414 (GCVE-0-2022-25414)
Vulnerability from cvelistv5
Published
2022-02-22 22:44
Modified
2024-08-03 04:42
Severity ?
CWE
  • n/a
Summary
Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the parameter NPTR.
References
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:42:49.462Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/1"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the parameter NPTR."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-02-22T22:44:14",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/1"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-25414",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the parameter NPTR."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/1",
              "refsource": "MISC",
              "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/1"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-25414",
    "datePublished": "2022-02-22T22:44:14",
    "dateReserved": "2022-02-21T00:00:00",
    "dateUpdated": "2024-08-03T04:42:49.462Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-29385 (GCVE-0-2025-29385)
Vulnerability from cvelistv5
Published
2025-03-14 00:00
Modified
2025-03-19 18:36
Severity ?
CWE
  • n/a
Summary
In Tenda AC9 v1.0 V15.03.05.14_multi, the cloneType parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-29385",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-17T17:50:57.253724Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-787",
                "description": "CWE-787 Out-of-bounds Write",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-19T18:36:38.733Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Tenda AC9 v1.0 V15.03.05.14_multi, the cloneType parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-14T17:02:33.612Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/shuqi233/loophole/blob/main/Tenda%20AC9/AdvSetMacMtuWan3.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-29385",
    "datePublished": "2025-03-14T00:00:00.000Z",
    "dateReserved": "2025-03-11T00:00:00.000Z",
    "dateUpdated": "2025-03-19T18:36:38.733Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-41560 (GCVE-0-2023-41560)
Vulnerability from cvelistv5
Published
2023-08-30 00:00
Modified
2024-10-01 19:01
Severity ?
CWE
  • n/a
Summary
Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter firewallEn at url /goform/SetFirewallCfg.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T19:01:35.244Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/peris-navince/founded-0-days/blob/main/formSetFirewallCfg/1.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac9",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "3.0_v15.03.06.42_multi"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-41560",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-01T19:00:46.816681Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-01T19:01:34.089Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter firewallEn at url /goform/SetFirewallCfg."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-30T12:34:58.440964",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/peris-navince/founded-0-days/blob/main/formSetFirewallCfg/1.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-41560",
    "datePublished": "2023-08-30T00:00:00",
    "dateReserved": "2023-08-30T00:00:00",
    "dateUpdated": "2024-10-01T19:01:34.089Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-18709 (GCVE-0-2018-18709)
Vulnerability from cvelistv5
Published
2018-10-27 22:00
Modified
2024-08-05 11:16
Severity ?
CWE
  • n/a
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "firewallEn" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:16:00.371Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-10-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"firewallEn\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-27T22:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-18709",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"firewallEn\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md",
              "refsource": "MISC",
              "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-18709",
    "datePublished": "2018-10-27T22:00:00",
    "dateReserved": "2018-10-27T00:00:00",
    "dateUpdated": "2024-08-05T11:16:00.371Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-25748 (GCVE-0-2024-25748)
Vulnerability from cvelistv5
Published
2024-02-22 00:00
Modified
2024-08-28 17:55
CWE
  • n/a
Summary
A Stack Based Buffer Overflow vulnerability in tenda AC9 AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the fromSetIpMacBind function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T23:52:05.187Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/TimeSeg/IOT_CVE/blob/main/tenda/AC9V3/0218/fromSetIpMacBind.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac9v3.0_firmware:15.03.06.42_multi:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac9v3.0_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.42_multi"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-25748",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-02-26T17:08:35.198529Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-28T17:55:46.333Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A Stack Based Buffer Overflow vulnerability in tenda AC9 AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the fromSetIpMacBind function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-22T22:13:47.569258",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/TimeSeg/IOT_CVE/blob/main/tenda/AC9V3/0218/fromSetIpMacBind.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-25748",
    "datePublished": "2024-02-22T00:00:00",
    "dateReserved": "2024-02-12T00:00:00",
    "dateUpdated": "2024-08-28T17:55:46.333Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-27016 (GCVE-0-2022-27016)
Vulnerability from cvelistv5
Published
2022-04-07 14:20
Modified
2024-08-03 05:18
Severity ?
CWE
  • n/a
Summary
There is a stack overflow vulnerability in the SetStaticRouteCfg() function in the httpd service of Tenda AC9 15.03.2.21_cn.
References
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:18:39.279Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/10"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "There is a stack overflow vulnerability in the SetStaticRouteCfg() function in the httpd service of Tenda AC9 15.03.2.21_cn."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-07T14:20:03",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/10"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-27016",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "There is a stack overflow vulnerability in the SetStaticRouteCfg() function in the httpd service of Tenda AC9 15.03.2.21_cn."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/10",
              "refsource": "MISC",
              "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/10"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-27016",
    "datePublished": "2022-04-07T14:20:03",
    "dateReserved": "2022-03-14T00:00:00",
    "dateUpdated": "2024-08-03T05:18:39.279Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-18707 (GCVE-0-2018-18707)
Vulnerability from cvelistv5
Published
2018-10-27 22:00
Modified
2024-08-05 11:16
Severity ?
CWE
  • n/a
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "ssid" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:16:00.407Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-10-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"ssid\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-27T22:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-18707",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"ssid\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md",
              "refsource": "MISC",
              "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-18707",
    "datePublished": "2018-10-27T22:00:00",
    "dateReserved": "2018-10-27T00:00:00",
    "dateUpdated": "2024-08-05T11:16:00.407Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-25756 (GCVE-0-2024-25756)
Vulnerability from cvelistv5
Published
2024-02-22 00:00
Modified
2024-08-01 23:52
CWE
  • n/a
Summary
A Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the formWifiBasicSet function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac9v3.0_firmware:15.03.06.42_multi:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac9v3.0_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.42_multi"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-25756",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-26T15:04:35.565398Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-26T16:39:27.980Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T23:52:05.902Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/TimeSeg/IOT_CVE/blob/main/tenda/AC9V3/0218/formWifiBasicSet.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the formWifiBasicSet function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-22T22:07:29.432369",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/TimeSeg/IOT_CVE/blob/main/tenda/AC9V3/0218/formWifiBasicSet.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-25756",
    "datePublished": "2024-02-22T00:00:00",
    "dateReserved": "2024-02-12T00:00:00",
    "dateUpdated": "2024-08-01T23:52:05.902Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-14558 (GCVE-0-2018-14558)
Vulnerability from cvelistv5
Published
2018-10-30 18:00
Modified
2025-07-30 01:46
Severity ?
CWE
  • n/a
Summary
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T09:29:51.678Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2018-14558",
                "options": [
                  {
                    "Exploitation": "active"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-04T20:44:12.590931Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          },
          {
            "other": {
              "content": {
                "dateAdded": "2021-11-03",
                "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2018-14558"
              },
              "type": "kev"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-78",
                "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-30T01:46:12.082Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "timeline": [
          {
            "lang": "en",
            "time": "2021-11-03T00:00:00+00:00",
            "value": "CVE-2018-14558 added to CISA KEV"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-07-21T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the \"formsetUsbUnload\" function executes a dosystemCmd function with untrusted input."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-30T17:57:01.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-14558",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the \"formsetUsbUnload\" function executes a dosystemCmd function with untrusted input."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md",
              "refsource": "MISC",
              "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-14558",
    "datePublished": "2018-10-30T18:00:00.000Z",
    "dateReserved": "2018-07-23T00:00:00.000Z",
    "dateUpdated": "2025-07-30T01:46:12.082Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-29386 (GCVE-0-2025-29386)
Vulnerability from cvelistv5
Published
2025-03-14 00:00
Modified
2025-03-19 18:35
Severity ?
CWE
  • n/a
Summary
In Tenda AC9 v1.0 V15.03.05.14_multi, the mac parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-29386",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-17T17:34:56.870290Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-787",
                "description": "CWE-787 Out-of-bounds Write",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-19T18:35:49.191Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Tenda AC9 v1.0 V15.03.05.14_multi, the mac parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-14T17:01:10.670Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/shuqi233/loophole/blob/main/Tenda%20AC9/AdvSetMacMtuWan4.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-29386",
    "datePublished": "2025-03-14T00:00:00.000Z",
    "dateReserved": "2025-03-11T00:00:00.000Z",
    "dateUpdated": "2025-03-19T18:35:49.191Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25434 (GCVE-0-2022-25434)
Vulnerability from cvelistv5
Published
2022-03-18 20:53
Modified
2024-08-03 04:42
Severity ?
CWE
  • n/a
Summary
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the firewallen parameter in the SetFirewallCfg function.
References
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:42:48.938Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/6"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the firewallen parameter in the SetFirewallCfg function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-18T20:53:06",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/6"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-25434",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the firewallen parameter in the SetFirewallCfg function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/6",
              "refsource": "MISC",
              "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/6"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-25434",
    "datePublished": "2022-03-18T20:53:06",
    "dateReserved": "2022-02-21T00:00:00",
    "dateUpdated": "2024-08-03T04:42:48.938Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25441 (GCVE-0-2022-25441)
Vulnerability from cvelistv5
Published
2022-03-18 20:53
Modified
2024-08-03 04:42
Severity ?
CWE
  • n/a
Summary
Tenda AC9 v15.03.2.21 was discovered to contain a remote command execution (RCE) vulnerability via the vlanid parameter in the SetIPTVCfg function.
References
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:42:49.361Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/12"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 v15.03.2.21 was discovered to contain a remote command execution (RCE) vulnerability via the vlanid parameter in the SetIPTVCfg function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-18T20:53:13",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/12"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-25441",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC9 v15.03.2.21 was discovered to contain a remote command execution (RCE) vulnerability via the vlanid parameter in the SetIPTVCfg function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/12",
              "refsource": "MISC",
              "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/12"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-25441",
    "datePublished": "2022-03-18T20:53:13",
    "dateReserved": "2022-02-21T00:00:00",
    "dateUpdated": "2024-08-03T04:42:49.361Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-37717 (GCVE-0-2023-37717)
Vulnerability from cvelistv5
Published
2023-07-14 00:00
Modified
2024-10-30 15:39
Severity ?
CWE
  • n/a
Summary
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:23:27.232Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromDhcpListClient/repot.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "f1202",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V1.0BR_V1.2.0.20(408)"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:fh1202:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1202",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V1.2.0.19_EN"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V1.0,"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac1206",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V1.0"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac7",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V1.0"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac5",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V1.0"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac9",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V3.0"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-37717",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-30T15:36:28.731124Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-30T15:39:40.848Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-07-14T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromDhcpListClient/repot.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-37717",
    "datePublished": "2023-07-14T00:00:00",
    "dateReserved": "2023-07-10T00:00:00",
    "dateUpdated": "2024-10-30T15:39:40.848Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-25751 (GCVE-0-2024-25751)
Vulnerability from cvelistv5
Published
2024-02-26 00:00
Modified
2024-08-27 19:00
Severity ?
CWE
  • n/a
Summary
A Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the fromSetSysTime function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T23:52:05.732Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/TimeSeg/IOT_CVE/blob/main/tenda/AC9V3/0218/fromSetSysTime.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac9_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.42_multi"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-25751",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-02-27T20:53:29.850988Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-27T19:00:23.880Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the fromSetSysTime function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-26T21:26:40.354469",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/TimeSeg/IOT_CVE/blob/main/tenda/AC9V3/0218/fromSetSysTime.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-25751",
    "datePublished": "2024-02-26T00:00:00",
    "dateReserved": "2024-02-12T00:00:00",
    "dateUpdated": "2024-08-27T19:00:23.880Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-42659 (GCVE-0-2021-42659)
Vulnerability from cvelistv5
Published
2022-05-24 11:41
Modified
2024-08-04 03:38
Severity ?
CWE
  • n/a
Summary
There is a buffer overflow vulnerability in the Web server httpd of the router in Tenda router devices such as Tenda AC9 V1.0 V15.03.02.19(6318) and Tenda AC9 V3.0 V15.03.06.42_multi. When setting the virtual service, the httpd program will crash and exit when the super-long list parameter occurs.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T03:38:50.080Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Lyc-heng/routers/blob/main/routers/stack4.md"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cnvd.org.cn/flaw/show/CNVD-2021-24948"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "There is a buffer overflow vulnerability in the Web server httpd of the router in Tenda router devices such as Tenda AC9 V1.0 V15.03.02.19(6318) and Tenda AC9 V3.0 V15.03.06.42_multi. When setting the virtual service, the httpd program will crash and exit when the super-long list parameter occurs."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-24T11:41:53",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Lyc-heng/routers/blob/main/routers/stack4.md"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cnvd.org.cn/flaw/show/CNVD-2021-24948"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-42659",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "There is a buffer overflow vulnerability in the Web server httpd of the router in Tenda router devices such as Tenda AC9 V1.0 V15.03.02.19(6318) and Tenda AC9 V3.0 V15.03.06.42_multi. When setting the virtual service, the httpd program will crash and exit when the super-long list parameter occurs."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/Lyc-heng/routers/blob/main/routers/stack4.md",
              "refsource": "MISC",
              "url": "https://github.com/Lyc-heng/routers/blob/main/routers/stack4.md"
            },
            {
              "name": "https://www.cnvd.org.cn/flaw/show/CNVD-2021-24948",
              "refsource": "MISC",
              "url": "https://www.cnvd.org.cn/flaw/show/CNVD-2021-24948"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-42659",
    "datePublished": "2022-05-24T11:41:53",
    "dateReserved": "2021-10-18T00:00:00",
    "dateUpdated": "2024-08-04T03:38:50.080Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25427 (GCVE-0-2022-25427)
Vulnerability from cvelistv5
Published
2022-03-18 20:52
Modified
2024-08-03 04:42
Severity ?
CWE
  • n/a
Summary
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the schedendtime parameter in the openSchedWifi function.
References
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:42:49.423Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/2"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the schedendtime parameter in the openSchedWifi function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-18T20:52:57",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/2"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-25427",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the schedendtime parameter in the openSchedWifi function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/2",
              "refsource": "MISC",
              "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/2"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-25427",
    "datePublished": "2022-03-18T20:52:57",
    "dateReserved": "2022-02-21T00:00:00",
    "dateUpdated": "2024-08-03T04:42:49.423Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-5900 (GCVE-0-2025-5900)
Vulnerability from cvelistv5
Published
2025-06-09 22:00
Modified
2025-06-10 15:29
CWE
  • CWE-352 - Cross-Site Request Forgery
  • CWE-862 - Missing Authorization
Summary
A vulnerability, which was classified as problematic, was found in Tenda AC9 15.03.02.13. This affects an unknown part. The manipulation leads to cross-site request forgery. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
Impacted products
Vendor Product Version
Tenda AC9 Version: 15.03.02.13
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-5900",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-10T14:21:05.917336Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-10T15:29:00.898Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://candle-throne-f75.notion.site/Tenda-AC9-fromSysToolRestoreSet-20adf0aa11858094a25ae21f9b4203da"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.02.13"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "ysnysn0121 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as problematic, was found in Tenda AC9 15.03.02.13. This affects an unknown part. The manipulation leads to cross-site request forgery. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Es wurde eine problematische Schwachstelle in Tenda AC9 15.03.02.13 gefunden. Dabei betrifft es einen unbekannter Codeteil. Durch Beeinflussen mit unbekannten Daten kann eine cross-site request forgery-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-352",
              "description": "Cross-Site Request Forgery",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-862",
              "description": "Missing Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-09T22:00:19.518Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-311673 | Tenda AC9 cross-site request forgery",
          "tags": [
            "vdb-entry"
          ],
          "url": "https://vuldb.com/?id.311673"
        },
        {
          "name": "VDB-311673 | CTI Indicators (IOB, IOC)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.311673"
        },
        {
          "name": "Submit #592198 | Tenda AC9 V1.0 V15.03.02.13 Cross Site Request Forgery",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.592198"
        },
        {
          "name": "Submit #592199 | Tenda AC9 V1.0 V15.03.02.13 Cross Site Request Forgery (Duplicate)",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.592199"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://candle-throne-f75.notion.site/Tenda-AC9-fromSysToolReboot-20adf0aa1185806a9d20ee5c355c08a6?pvs=73"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://candle-throne-f75.notion.site/Tenda-AC9-fromSysToolRestoreSet-20adf0aa11858094a25ae21f9b4203da"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-06-09T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-06-09T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-06-09T09:47:36.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC9 cross-site request forgery"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-5900",
    "datePublished": "2025-06-09T22:00:19.518Z",
    "dateReserved": "2025-06-09T07:42:33.564Z",
    "dateUpdated": "2025-06-10T15:29:00.898Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25440 (GCVE-0-2022-25440)
Vulnerability from cvelistv5
Published
2022-03-18 20:53
Modified
2024-08-03 04:42
Severity ?
CWE
  • n/a
Summary
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the ntpserver parameter in the SetSysTimeCfg function.
References
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:42:49.377Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/13"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the ntpserver parameter in the SetSysTimeCfg function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-18T20:53:12",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/13"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-25440",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the ntpserver parameter in the SetSysTimeCfg function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/13",
              "refsource": "MISC",
              "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/13"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-25440",
    "datePublished": "2022-03-18T20:53:12",
    "dateReserved": "2022-02-21T00:00:00",
    "dateUpdated": "2024-08-03T04:42:49.377Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-41559 (GCVE-0-2023-41559)
Vulnerability from cvelistv5
Published
2023-08-30 00:00
Modified
2024-10-01 19:28
Severity ?
CWE
  • n/a
Summary
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T19:01:35.261Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromNatStaticSetting/1.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac7",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.0_v15.03.06.44"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac9",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "3.0_v15.03.06.42_multi,"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac5",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.0rtl_v15.03.06.28"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-41559",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-01T19:26:04.363328Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-01T19:28:01.330Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-30T12:19:49.860110",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromNatStaticSetting/1.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-41559",
    "datePublished": "2023-08-30T00:00:00",
    "dateReserved": "2023-08-30T00:00:00",
    "dateUpdated": "2024-10-01T19:28:01.330Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-10280 (GCVE-0-2024-10280)
Vulnerability from cvelistv5
Published
2024-10-23 13:31
Modified
2024-10-23 17:41
CWE
  • CWE-476 - NULL Pointer Dereference
Summary
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac6_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.23"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac8_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "16.03.34.06"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac8_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "16.03.34.09"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "16.03.48.23"
              },
              {
                "status": "affected",
                "version": "16.03.48.19"
              },
              {
                "status": "affected",
                "version": "16.03.48.20"
              },
              {
                "status": "affected",
                "version": "16.03.48.13"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac1206_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.23"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac9_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.42"
              },
              {
                "status": "affected",
                "version": "15.03.05.19\\(6318_\\)"
              },
              {
                "status": "affected",
                "version": "15.03.05.14"
              },
              {
                "status": "affected",
                "version": "15.03.2.13"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac18_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.05"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac18_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.19\\(6318\\)"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac500_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "2.0.1.9\\(1307\\)"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac500_firmware:1.0.0.16:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac500_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.0.16"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac500_firmware:1.0.0.14:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac500_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.0.14"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10u_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.48"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10u_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.49"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac7_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.44"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac15_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.18"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac15_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.19"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10280",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-23T17:28:19.760214Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-23T17:41:57.370Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC6",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC7",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC8",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC10U",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC15",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC18",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC500",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        },
        {
          "product": "AC1206",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241022"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "minipython (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 bis 20241022 ausgemacht. Sie wurde als problematisch eingestuft. Davon betroffen ist die Funktion websReadEvent der Datei /goform/GetIPTV. Durch Beeinflussen des Arguments Content-Length mit unbekannten Daten kann eine null pointer dereference-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.8,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-476",
              "description": "NULL Pointer Dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-23T13:31:07.315Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-281555 | Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.281555"
        },
        {
          "name": "VDB-281555 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.281555"
        },
        {
          "name": "Submit #426417 | Tenda AC8v4 V16.03.34.06 NULL Pointer Dereference",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.426417"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/JohenanLi/router_vuls/blob/main/websReadEvent/websReadEvent.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-10-23T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-10-23T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-10-23T08:07:55.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-10280",
    "datePublished": "2024-10-23T13:31:07.315Z",
    "dateReserved": "2024-10-23T06:02:03.363Z",
    "dateUpdated": "2024-10-23T17:41:57.370Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-18706 (GCVE-0-2018-18706)
Vulnerability from cvelistv5
Published
2018-10-27 22:00
Modified
2024-08-05 11:16
Severity ?
CWE
  • n/a
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromDhcpListClient" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:16:00.389Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-10-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromDhcpListClient\" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-27T22:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-18706",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromDhcpListClient\" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md",
              "refsource": "MISC",
              "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-18706",
    "datePublished": "2018-10-27T22:00:00",
    "dateReserved": "2018-10-27T00:00:00",
    "dateUpdated": "2024-08-05T11:16:00.389Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-41552 (GCVE-0-2023-41552)
Vulnerability from cvelistv5
Published
2023-08-30 00:00
Modified
2024-10-01 19:49
Severity ?
CWE
  • n/a
Summary
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T19:01:35.281Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/peris-navince/founded-0-days/blob/main/form_fast_setting_wifi_set/1.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac7",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.0_v15.03.06.44"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac9",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "3.0_v15.03.06.42_multi"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-41552",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-01T19:48:17.214882Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-01T19:49:40.131Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-30T12:28:31.907320",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/peris-navince/founded-0-days/blob/main/form_fast_setting_wifi_set/1.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-41552",
    "datePublished": "2023-08-30T00:00:00",
    "dateReserved": "2023-08-30T00:00:00",
    "dateUpdated": "2024-10-01T19:49:40.131Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-44872 (GCVE-0-2025-44872)
Vulnerability from cvelistv5
Published
2025-05-02 00:00
Modified
2025-05-06 15:17
Severity ?
CWE
  • n/a
Summary
Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formsetUsbUnload function via the deviceName parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-44872",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-06T15:17:17.673448Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-77",
                "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-06T15:17:45.827Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/Summermu/VulnForIoT/tree/main/Tenda_AC/AC9_formsetUsbUnload"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formsetUsbUnload function via the deviceName parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-02T14:39:25.635Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/Summermu/VulnForIoT/tree/main/Tenda_AC/AC9_formsetUsbUnload"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-44872",
    "datePublished": "2025-05-02T00:00:00.000Z",
    "dateReserved": "2025-04-22T00:00:00.000Z",
    "dateUpdated": "2025-05-06T15:17:45.827Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-41553 (GCVE-0-2023-41553)
Vulnerability from cvelistv5
Published
2023-08-30 00:00
Modified
2024-10-01 19:47
Severity ?
CWE
  • n/a
Summary
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T19:01:35.339Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetRouteStatic/1.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac9",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "3.0_v15.03.06.42_multi"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac5",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.0rtl_v15.03.06.28"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-41553",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-01T19:45:49.593482Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-01T19:47:38.332Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-30T12:31:36.490197",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetRouteStatic/1.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-41553",
    "datePublished": "2023-08-30T00:00:00",
    "dateReserved": "2023-08-30T00:00:00",
    "dateUpdated": "2024-10-01T19:47:38.332Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-45428 (GCVE-0-2025-45428)
Vulnerability from cvelistv5
Published
2025-04-23 00:00
Modified
2025-04-23 15:27
Severity ?
CWE
  • n/a
Summary
In Tenda ac9 v1.0 with firmware V15.03.05.14_multi, the rebootTime parameter of /goform/SetSysAutoRebbotCfg has a stack overflow vulnerability, which can lead to remote arbitrary code execution.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-45428",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-23T15:26:15.768194Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-23T15:27:31.015Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/shuqi233/loophole/blob/main/Tenda%20AC9/SetSysAutoRebbotCfg-rebootTime.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Tenda ac9 v1.0 with firmware V15.03.05.14_multi, the rebootTime parameter of /goform/SetSysAutoRebbotCfg has a stack overflow vulnerability, which can lead to remote arbitrary code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-23T15:03:52.990Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/shuqi233/loophole/blob/main/Tenda%20AC9/SetSysAutoRebbotCfg-rebootTime.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-45428",
    "datePublished": "2025-04-23T00:00:00.000Z",
    "dateReserved": "2025-04-22T00:00:00.000Z",
    "dateUpdated": "2025-04-23T15:27:31.015Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-18728 (GCVE-0-2018-18728)
Vulnerability from cvelistv5
Published
2018-10-28 00:00
Modified
2024-08-05 11:16
Severity ?
CWE
  • n/a
Summary
An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. They allow remote code execution via shell metacharacters in the usbName field to the __fastcall function with a POST request.
References
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:16:00.397Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/rce1.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-10-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. They allow remote code execution via shell metacharacters in the usbName field to the __fastcall function with a POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-28T00:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/rce1.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-18728",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. They allow remote code execution via shell metacharacters in the usbName field to the __fastcall function with a POST request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/rce1.md",
              "refsource": "MISC",
              "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/rce1.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-18728",
    "datePublished": "2018-10-28T00:00:00",
    "dateReserved": "2018-10-27T00:00:00",
    "dateUpdated": "2024-08-05T11:16:00.397Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-29387 (GCVE-0-2025-29387)
Vulnerability from cvelistv5
Published
2025-03-14 00:00
Modified
2025-03-17 18:34
CWE
  • n/a
Summary
In Tenda AC9 v1.0 V15.03.05.14_multi, the wanSpeed parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.1,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-29387",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-17T17:33:41.968213Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-17T18:34:19.639Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Tenda AC9 v1.0 V15.03.05.14_multi, the wanSpeed parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-14T16:59:30.049Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/shuqi233/loophole/blob/main/Tenda%20AC9/AdvSetMacMtuWan2.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-29387",
    "datePublished": "2025-03-14T00:00:00.000Z",
    "dateReserved": "2025-03-11T00:00:00.000Z",
    "dateUpdated": "2025-03-17T18:34:19.639Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25439 (GCVE-0-2022-25439)
Vulnerability from cvelistv5
Published
2022-03-18 20:53
Modified
2024-08-03 04:42
Severity ?
CWE
  • n/a
Summary
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetIpMacBind function.
References
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:42:48.954Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/8"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetIpMacBind function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-18T20:53:11",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/8"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-25439",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetIpMacBind function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/8",
              "refsource": "MISC",
              "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/8"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-25439",
    "datePublished": "2022-03-18T20:53:11",
    "dateReserved": "2022-02-21T00:00:00",
    "dateUpdated": "2024-08-03T04:42:48.954Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-36568 (GCVE-0-2022-36568)
Vulnerability from cvelistv5
Published
2022-08-31 19:03
Modified
2024-08-03 10:07
Severity ?
CWE
  • n/a
Summary
Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the list parameter at /goform/setPptpUserList.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:07:34.499Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/CyberUnicornIoT/IoTvuln/blob/main/Tenda_ac9/3/tenda_ac9_setPptpUserList.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the list parameter at /goform/setPptpUserList."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-31T19:03:24",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/CyberUnicornIoT/IoTvuln/blob/main/Tenda_ac9/3/tenda_ac9_setPptpUserList.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-36568",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the list parameter at /goform/setPptpUserList."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/CyberUnicornIoT/IoTvuln/blob/main/Tenda_ac9/3/tenda_ac9_setPptpUserList.md",
              "refsource": "MISC",
              "url": "https://github.com/CyberUnicornIoT/IoTvuln/blob/main/Tenda_ac9/3/tenda_ac9_setPptpUserList.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-36568",
    "datePublished": "2022-08-31T19:03:24",
    "dateReserved": "2022-07-25T00:00:00",
    "dateUpdated": "2024-08-03T10:07:34.499Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-38930 (GCVE-0-2023-38930)
Vulnerability from cvelistv5
Published
2023-08-07 00:00
Modified
2024-10-15 19:35
Severity ?
CWE
  • n/a
Summary
Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:54:39.646Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/addWifiMacFilter/README.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac7",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V1.0,V15.03.06.44"
              },
              {
                "status": "affected",
                "version": "F1203 V2.0.1.6,"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac5",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V1.0,V15.03.06.28"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac9",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V3.0,V15.03.06.42_multi"
              },
              {
                "status": "affected",
                "version": "FH1205 V2.0.0.7(775)"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-38930",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-15T19:31:04.398117Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-15T19:35:44.164Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-07T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/addWifiMacFilter/README.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-38930",
    "datePublished": "2023-08-07T00:00:00",
    "dateReserved": "2023-07-25T00:00:00",
    "dateUpdated": "2024-10-15T19:35:44.164Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-41554 (GCVE-0-2023-41554)
Vulnerability from cvelistv5
Published
2023-08-30 00:00
Modified
2024-10-01 19:44
Severity ?
CWE
  • n/a
Summary
Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter wpapsk_crypto at url /goform/WifiExtraSet.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T19:01:35.257Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetWirelessRepeat/1.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac9",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "3.0_v15.03.06.42_multi"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-41554",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-01T19:43:31.743277Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-01T19:44:11.184Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter wpapsk_crypto at url /goform/WifiExtraSet."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-30T12:33:40.068235",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetWirelessRepeat/1.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-41554",
    "datePublished": "2023-08-30T00:00:00",
    "dateReserved": "2023-08-30T00:00:00",
    "dateUpdated": "2024-10-01T19:44:11.184Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-37716 (GCVE-0-2023-37716)
Vulnerability from cvelistv5
Published
2023-07-14 00:00
Modified
2024-10-30 15:44
Severity ?
CWE
  • n/a
Summary
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:23:26.317Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromNatStaticSetting/report.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "f1202",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V1.0BR_V1.2.0.20(408)"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:fh1202:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1202",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V1.2.0.19_EN"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "v.1.0"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac1206",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "v1.0"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac7",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "v1.0"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac5",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "v1.0"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac9",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "v3.0"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-37716",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-30T15:41:48.422746Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-30T15:44:13.700Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-07-14T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromNatStaticSetting/report.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-37716",
    "datePublished": "2023-07-14T00:00:00",
    "dateReserved": "2023-07-10T00:00:00",
    "dateUpdated": "2024-10-30T15:44:13.700Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-38936 (GCVE-0-2023-38936)
Vulnerability from cvelistv5
Published
2023-08-07 00:00
Modified
2024-10-15 20:05
Severity ?
CWE
  • n/a
Summary
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:54:39.689Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetSpeedWan/README.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V1.0 V15.03.06.23"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac1206",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V15.03.06.23,"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac6:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac6",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V2.0 V15.03.06.23"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac7",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V1.0 V15.03.06.44,"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac5",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V1.0 V15.03.06.28"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1203",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V2.0.1.6"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac9",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V3.0 V15.03.06.42_multi"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1205",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V2.0.0.7(775)"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-38936",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-15T20:02:03.283677Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-15T20:05:36.911Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-07T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetSpeedWan/README.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-38936",
    "datePublished": "2023-08-07T00:00:00",
    "dateReserved": "2023-07-25T00:00:00",
    "dateUpdated": "2024-10-15T20:05:36.911Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-38937 (GCVE-0-2023-38937)
Vulnerability from cvelistv5
Published
2023-08-07 00:00
Modified
2024-10-17 14:40
Severity ?
CWE
  • n/a
Summary
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:54:39.643Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetVirtualSer/README.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac6:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac6",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V2.0 V15.03.06.23"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V1.0 V15.03.06.23"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac1206",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V15.03.06.23"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac8",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "v4 V16.03.34.06"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac7",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V1.0 V15.03.06.44"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac5",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V1.0 V15.03.06.28"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac9",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V3.0 V15.03.06.42_multi"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "v4.0 V16.03.10.13"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-38937",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-17T14:37:17.298133Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-17T14:40:31.909Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-07T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetVirtualSer/README.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-38937",
    "datePublished": "2023-08-07T00:00:00",
    "dateReserved": "2023-07-25T00:00:00",
    "dateUpdated": "2024-10-17T14:40:31.909Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-5839 (GCVE-0-2025-5839)
Vulnerability from cvelistv5
Published
2025-06-07 17:31
Modified
2025-06-09 03:34
CWE
Summary
A vulnerability, which was classified as critical, has been found in Tenda AC9 15.03.02.13. Affected by this issue is the function fromadvsetlanip of the file /goform/AdvSetLanip of the component POST Request Handler. The manipulation of the argument lanMask leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
Impacted products
Vendor Product Version
Tenda AC9 Version: 15.03.02.13
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-5839",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-09T03:34:33.186014Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-09T03:34:50.223Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "POST Request Handler"
          ],
          "product": "AC9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.02.13"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "ysnysn0121 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, has been found in Tenda AC9 15.03.02.13. Affected by this issue is the function fromadvsetlanip of the file /goform/AdvSetLanip of the component POST Request Handler. The manipulation of the argument lanMask leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in Tenda AC9 15.03.02.13 entdeckt. Dies betrifft die Funktion fromadvsetlanip der Datei /goform/AdvSetLanip der Komponente POST Request Handler. Durch das Manipulieren des Arguments lanMask mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-07T17:31:13.113Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-311582 | Tenda AC9 POST Request AdvSetLanip fromadvsetlanip buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.311582"
        },
        {
          "name": "VDB-311582 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.311582"
        },
        {
          "name": "Submit #591369 | Tenda AC9 V1.0 V15.03.02.13 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.591369"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://candle-throne-f75.notion.site/Tenda-AC9-fromadvsetlanip-20adf0aa11858027b7c3c2f4e44bb867"
        },
        {
          "tags": [
            "broken-link",
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-06-06T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-06-06T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-06-06T22:21:47.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC9 POST Request AdvSetLanip fromadvsetlanip buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-5839",
    "datePublished": "2025-06-07T17:31:13.113Z",
    "dateReserved": "2025-06-06T20:16:06.753Z",
    "dateUpdated": "2025-06-09T03:34:50.223Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-38933 (GCVE-0-2023-38933)
Vulnerability from cvelistv5
Published
2023-08-07 00:00
Modified
2024-10-17 13:51
Severity ?
CWE
  • n/a
Summary
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:54:39.649Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetClientState/README.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac7",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V1.0 V15.03.06.44"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "f1203",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V2.0.1.6"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac5",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V1.0 V15.03.06.28"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1203",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V2.0.1.6"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac9",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V3.0 V15.03.06.42_multi"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fh1205",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V2.0.0.7(775)"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac6:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac6",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "V2.0 V15.03.06.23"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-38933",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-17T13:48:33.206945Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-17T13:51:46.931Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-07T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetClientState/README.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-38933",
    "datePublished": "2023-08-07T00:00:00",
    "dateReserved": "2023-07-25T00:00:00",
    "dateUpdated": "2024-10-17T13:51:46.931Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-45429 (GCVE-0-2025-45429)
Vulnerability from cvelistv5
Published
2025-04-23 00:00
Modified
2025-04-23 15:30
Severity ?
CWE
  • n/a
Summary
In the Tenda ac9 v1.0 router with firmware V15.03.05.14_multi, there is a stack overflow vulnerability in /goform/WifiWpsStart, which may lead to remote arbitrary code execution.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-45429",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-23T15:28:52.022404Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-23T15:30:33.643Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/shuqi233/loophole/blob/main/Tenda%20AC9/WifiWpsStart-index.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In the Tenda ac9 v1.0 router with firmware V15.03.05.14_multi, there is a stack overflow vulnerability in /goform/WifiWpsStart, which may lead to remote arbitrary code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-23T15:07:01.854Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/shuqi233/loophole/blob/main/Tenda%20AC9/WifiWpsStart-index.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-45429",
    "datePublished": "2025-04-23T00:00:00.000Z",
    "dateReserved": "2025-04-22T00:00:00.000Z",
    "dateUpdated": "2025-04-23T15:30:33.643Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-44877 (GCVE-0-2025-44877)
Vulnerability from cvelistv5
Published
2025-05-02 00:00
Modified
2025-05-06 15:16
Severity ?
CWE
  • n/a
Summary
Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formSetSambaConf function via the usbname parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-44877",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-06T15:16:10.418505Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-77",
                "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-06T15:16:43.764Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/Summermu/VulnForIoT/tree/main/Tenda_AC/AC9_formSetSambaConf"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formSetSambaConf function via the usbname parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-02T14:35:48.519Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/Summermu/VulnForIoT/tree/main/Tenda_AC/AC9_formSetSambaConf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-44877",
    "datePublished": "2025-05-02T00:00:00.000Z",
    "dateReserved": "2025-04-22T00:00:00.000Z",
    "dateUpdated": "2025-05-06T15:16:43.764Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25437 (GCVE-0-2022-25437)
Vulnerability from cvelistv5
Published
2022-03-18 20:53
Modified
2024-08-03 04:42
Severity ?
CWE
  • n/a
Summary
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetVirtualServerCfg function.
References
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:42:48.947Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/9"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetVirtualServerCfg function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-18T20:53:10",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/9"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-25437",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetVirtualServerCfg function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/9",
              "refsource": "MISC",
              "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/9"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-25437",
    "datePublished": "2022-03-18T20:53:10",
    "dateReserved": "2022-02-21T00:00:00",
    "dateUpdated": "2024-08-03T04:42:48.947Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-26728 (GCVE-0-2020-26728)
Vulnerability from cvelistv5
Published
2022-02-11 18:05
Modified
2024-08-04 15:56
Severity ?
CWE
  • n/a
Summary
A vulnerability was discovered in Tenda AC9 v3.0 V15.03.06.42_multi and Tenda AC9 V1.0 V15.03.05.19(6318)_CN which allows for remote code execution via shell metacharacters in the guestuser field to the __fastcall function with a POST request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T15:56:05.058Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Lyc-heng/Router/blob/main/Tenda/rce1.md"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Lyc-heng/routers/blob/a80b30bccfc9b76f3a4868ff28ad5ce2e0fca180/routers/rce1.md"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Lyc-heng/routers/blob/main/routers/rce1.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was discovered in Tenda AC9 v3.0 V15.03.06.42_multi and Tenda AC9 V1.0 V15.03.05.19(6318)_CN which allows for remote code execution via shell metacharacters in the guestuser field to the __fastcall function with a POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-02-17T13:58:54",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Lyc-heng/Router/blob/main/Tenda/rce1.md"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Lyc-heng/routers/blob/a80b30bccfc9b76f3a4868ff28ad5ce2e0fca180/routers/rce1.md"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Lyc-heng/routers/blob/main/routers/rce1.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-26728",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability was discovered in Tenda AC9 v3.0 V15.03.06.42_multi and Tenda AC9 V1.0 V15.03.05.19(6318)_CN which allows for remote code execution via shell metacharacters in the guestuser field to the __fastcall function with a POST request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/Lyc-heng/Router/blob/main/Tenda/rce1.md",
              "refsource": "MISC",
              "url": "https://github.com/Lyc-heng/Router/blob/main/Tenda/rce1.md"
            },
            {
              "name": "https://github.com/Lyc-heng/routers/blob/a80b30bccfc9b76f3a4868ff28ad5ce2e0fca180/routers/rce1.md",
              "refsource": "MISC",
              "url": "https://github.com/Lyc-heng/routers/blob/a80b30bccfc9b76f3a4868ff28ad5ce2e0fca180/routers/rce1.md"
            },
            {
              "name": "https://github.com/Lyc-heng/routers/blob/main/routers/rce1.md",
              "refsource": "MISC",
              "url": "https://github.com/Lyc-heng/routers/blob/main/routers/rce1.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-26728",
    "datePublished": "2022-02-11T18:05:36",
    "dateReserved": "2020-10-07T00:00:00",
    "dateUpdated": "2024-08-04T15:56:05.058Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-16936 (GCVE-0-2017-16936)
Vulnerability from cvelistv5
Published
2017-11-24 07:00
Modified
2024-08-05 20:43
Severity ?
CWE
  • n/a
Summary
Directory Traversal vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to read arbitrary files via a cgi-bin/luci/request?op=1&path= URI that uses directory traversal sequences after a /usb/ substring.
References
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T20:43:59.320Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Iolop/Poc/tree/master/Router/Tenda"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2017-11-24T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Directory Traversal vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to read arbitrary files via a cgi-bin/luci/request?op=1\u0026path= URI that uses directory traversal sequences after a /usb/ substring."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-11-24T07:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Iolop/Poc/tree/master/Router/Tenda"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2017-16936",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Directory Traversal vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to read arbitrary files via a cgi-bin/luci/request?op=1\u0026path= URI that uses directory traversal sequences after a /usb/ substring."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/Iolop/Poc/tree/master/Router/Tenda",
              "refsource": "MISC",
              "url": "https://github.com/Iolop/Poc/tree/master/Router/Tenda"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2017-16936",
    "datePublished": "2017-11-24T07:00:00",
    "dateReserved": "2017-11-24T00:00:00",
    "dateUpdated": "2024-08-05T20:43:59.320Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-7561 (GCVE-0-2018-7561)
Vulnerability from cvelistv5
Published
2018-03-01 15:00
Modified
2024-08-05 06:31
Severity ?
CWE
  • n/a
Summary
Stack-based Buffer Overflow in httpd on Tenda AC9 devices V15.03.05.14_EN allows remote attackers to cause a denial of service or possibly have unspecified other impact.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:31:04.412Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/VulDetailsPublication/Poc/tree/master/Tenda/AC9"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-03-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Stack-based Buffer Overflow in httpd on Tenda AC9 devices V15.03.05.14_EN allows remote attackers to cause a denial of service or possibly have unspecified other impact."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-01T14:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/VulDetailsPublication/Poc/tree/master/Tenda/AC9"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-7561",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Stack-based Buffer Overflow in httpd on Tenda AC9 devices V15.03.05.14_EN allows remote attackers to cause a denial of service or possibly have unspecified other impact."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/VulDetailsPublication/Poc/tree/master/Tenda/AC9",
              "refsource": "MISC",
              "url": "https://github.com/VulDetailsPublication/Poc/tree/master/Tenda/AC9"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-7561",
    "datePublished": "2018-03-01T15:00:00",
    "dateReserved": "2018-02-28T00:00:00",
    "dateUpdated": "2024-08-05T06:31:04.412Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-36569 (GCVE-0-2022-36569)
Vulnerability from cvelistv5
Published
2022-08-31 19:03
Modified
2024-08-03 10:07
Severity ?
CWE
  • n/a
Summary
Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the deviceList parameter at /goform/setMacFilterCfg.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:07:34.465Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/CyberUnicornIoT/IoTvuln/blob/main/Tenda_ac9/4/tenda_ac9_setMacFilterCfg.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the deviceList parameter at /goform/setMacFilterCfg."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-31T19:03:25",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/CyberUnicornIoT/IoTvuln/blob/main/Tenda_ac9/4/tenda_ac9_setMacFilterCfg.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-36569",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the deviceList parameter at /goform/setMacFilterCfg."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/CyberUnicornIoT/IoTvuln/blob/main/Tenda_ac9/4/tenda_ac9_setMacFilterCfg.md",
              "refsource": "MISC",
              "url": "https://github.com/CyberUnicornIoT/IoTvuln/blob/main/Tenda_ac9/4/tenda_ac9_setMacFilterCfg.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-36569",
    "datePublished": "2022-08-31T19:03:25",
    "dateReserved": "2022-07-25T00:00:00",
    "dateUpdated": "2024-08-03T10:07:34.465Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-5847 (GCVE-0-2025-5847)
Vulnerability from cvelistv5
Published
2025-06-08 13:31
Modified
2025-06-09 13:54
CWE
Summary
A vulnerability has been found in Tenda AC9 15.03.02.13 and classified as critical. Affected by this vulnerability is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg of the component HTTP POST Request Handler. The manipulation of the argument remoteIp leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Impacted products
Vendor Product Version
Tenda AC9 Version: 15.03.02.13
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-5847",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-09T13:53:24.790033Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-09T13:54:42.018Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "HTTP POST Request Handler"
          ],
          "product": "AC9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.02.13"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "ysnysnysn (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Tenda AC9 15.03.02.13 and classified as critical. Affected by this vulnerability is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg of the component HTTP POST Request Handler. The manipulation of the argument remoteIp leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "In Tenda AC9 15.03.02.13 wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Dabei geht es um die Funktion formSetSafeWanWebMan der Datei /goform/SetRemoteWebCfg der Komponente HTTP POST Request Handler. Durch das Manipulieren des Arguments remoteIp mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-08T13:32:05.147Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-311593 | Tenda AC9 HTTP POST Request SetRemoteWebCfg formSetSafeWanWebMan stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.311593"
        },
        {
          "name": "VDB-311593 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.311593"
        },
        {
          "name": "Submit #591362 | Tenda AC9 V1.0 V15.03.02.13 stack overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.591362"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://candle-throne-f75.notion.site/Tenda-AC9-formSetSafeWanWebMan-20adf0aa118580a29e80cef9109c947a"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-06-08T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-06-08T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-06-08T11:27:37.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC9 HTTP POST Request SetRemoteWebCfg formSetSafeWanWebMan stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-5847",
    "datePublished": "2025-06-08T13:31:44.996Z",
    "dateReserved": "2025-06-08T09:22:34.441Z",
    "dateUpdated": "2025-06-09T13:54:42.018Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-5836 (GCVE-0-2025-5836)
Vulnerability from cvelistv5
Published
2025-06-07 13:31
Modified
2025-06-09 15:06
CWE
Summary
A vulnerability was found in Tenda AC9 15.03.02.13. It has been rated as critical. This issue affects the function formSetIptv of the file /goform/SetIPTVCfg of the component POST Request Handler. The manipulation of the argument list leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Impacted products
Vendor Product Version
Tenda AC9 Version: 15.03.02.13
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-5836",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-09T15:06:27.930039Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-09T15:06:31.883Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://candle-throne-f75.notion.site/Tenda-AC9-formSetIptv-209df0aa11858061ae2bcbf83918d034"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "POST Request Handler"
          ],
          "product": "AC9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.02.13"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "ysnysn (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC9 15.03.02.13. It has been rated as critical. This issue affects the function formSetIptv of the file /goform/SetIPTVCfg of the component POST Request Handler. The manipulation of the argument list leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda AC9 15.03.02.13 ausgemacht. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion formSetIptv der Datei /goform/SetIPTVCfg der Komponente POST Request Handler. Durch Manipulation des Arguments list mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-07T13:31:06.620Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-311579 | Tenda AC9 POST Request SetIPTVCfg formSetIptv command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.311579"
        },
        {
          "name": "VDB-311579 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.311579"
        },
        {
          "name": "Submit #591363 | Tenda AC9 V1.0 V15.03.02.13 Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.591363"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://candle-throne-f75.notion.site/Tenda-AC9-formSetIptv-209df0aa11858061ae2bcbf83918d034"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-06-06T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-06-06T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-06-06T22:17:03.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC9 POST Request SetIPTVCfg formSetIptv command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-5836",
    "datePublished": "2025-06-07T13:31:06.620Z",
    "dateReserved": "2025-06-06T20:11:59.450Z",
    "dateUpdated": "2025-06-09T15:06:31.883Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-25753 (GCVE-0-2024-25753)
Vulnerability from cvelistv5
Published
2024-02-22 00:00
Modified
2024-08-01 23:52
CWE
  • n/a
Summary
Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the formSetDeviceName function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac9_firmware:3.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac9_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "3.0"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-25753",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-02-23T16:54:10.477155Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-25T20:25:26.262Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T23:52:06.359Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/TimeSeg/IOT_CVE/blob/main/tenda/AC9V3/0218/formSetDeviceName.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the formSetDeviceName function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-22T22:22:08.078344",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/TimeSeg/IOT_CVE/blob/main/tenda/AC9V3/0218/formSetDeviceName.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-25753",
    "datePublished": "2024-02-22T00:00:00",
    "dateReserved": "2024-02-12T00:00:00",
    "dateUpdated": "2024-08-01T23:52:06.359Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-41563 (GCVE-0-2023-41563)
Vulnerability from cvelistv5
Published
2023-08-30 00:00
Modified
2024-10-01 18:50
Severity ?
CWE
  • n/a
Summary
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T19:01:35.265Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/peris-navince/founded-0-days/blob/main/GetParentControlInfo/1.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac9",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "v3.0_v15.03.06.42_multi"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac5",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "us_ac5v1.0rtl_v15.03.06.28"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-41563",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-01T18:47:11.788881Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-01T18:50:56.783Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-30T12:38:53.547135",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/peris-navince/founded-0-days/blob/main/GetParentControlInfo/1.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-41563",
    "datePublished": "2023-08-30T00:00:00",
    "dateReserved": "2023-08-30T00:00:00",
    "dateUpdated": "2024-10-01T18:50:56.783Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25438 (GCVE-0-2022-25438)
Vulnerability from cvelistv5
Published
2022-03-18 20:53
Modified
2024-08-03 04:42
Severity ?
CWE
  • n/a
Summary
Tenda AC9 v15.03.2.21 was discovered to contain a remote command execution (RCE) vulnerability via the SetIPTVCfg function.
References
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:42:49.331Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/11"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 v15.03.2.21 was discovered to contain a remote command execution (RCE) vulnerability via the SetIPTVCfg function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-18T20:53:11",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/11"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-25438",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC9 v15.03.2.21 was discovered to contain a remote command execution (RCE) vulnerability via the SetIPTVCfg function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/11",
              "refsource": "MISC",
              "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/11"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-25438",
    "datePublished": "2022-03-18T20:53:11",
    "dateReserved": "2022-02-21T00:00:00",
    "dateUpdated": "2024-08-03T04:42:49.331Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25429 (GCVE-0-2022-25429)
Vulnerability from cvelistv5
Published
2022-03-18 20:53
Modified
2024-08-03 04:42
Severity ?
CWE
  • n/a
Summary
Tenda AC9 v15.03.2.21 was discovered to contain a buffer overflow via the time parameter in the saveparentcontrolinfo function.
References
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:42:49.387Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/1"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 v15.03.2.21 was discovered to contain a buffer overflow via the time parameter in the saveparentcontrolinfo function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-18T20:53:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/1"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-25429",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC9 v15.03.2.21 was discovered to contain a buffer overflow via the time parameter in the saveparentcontrolinfo function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/1",
              "refsource": "MISC",
              "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/1"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-25429",
    "datePublished": "2022-03-18T20:53:00",
    "dateReserved": "2022-02-21T00:00:00",
    "dateUpdated": "2024-08-03T04:42:49.387Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-25746 (GCVE-0-2024-25746)
Vulnerability from cvelistv5
Published
2024-02-22 00:00
Modified
2024-08-28 17:57
CWE
  • n/a
Summary
Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the add_white_node function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T23:52:05.655Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/TimeSeg/IOT_CVE/blob/main/tenda/AC9V3/0218/add_white_node.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac9v3.0_firmware:15.03.06.42_multi:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac9v3.0_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.42_multi"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-25746",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-28T17:56:32.766167Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-28T17:57:28.459Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the add_white_node function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-22T21:49:21.532882",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/TimeSeg/IOT_CVE/blob/main/tenda/AC9V3/0218/add_white_node.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-25746",
    "datePublished": "2024-02-22T00:00:00",
    "dateReserved": "2024-02-12T00:00:00",
    "dateUpdated": "2024-08-28T17:57:28.459Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25433 (GCVE-0-2022-25433)
Vulnerability from cvelistv5
Published
2022-03-18 20:53
Modified
2024-08-03 04:42
Severity ?
CWE
  • n/a
Summary
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the urls parameter in the saveparentcontrolinfo function.
References
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:42:49.749Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/5"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the urls parameter in the saveparentcontrolinfo function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-18T20:53:05",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/5"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-25433",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the urls parameter in the saveparentcontrolinfo function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/5",
              "refsource": "MISC",
              "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/5"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-25433",
    "datePublished": "2022-03-18T20:53:05",
    "dateReserved": "2022-02-21T00:00:00",
    "dateUpdated": "2024-08-03T04:42:49.749Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-36570 (GCVE-0-2022-36570)
Vulnerability from cvelistv5
Published
2022-08-31 19:03
Modified
2024-08-03 10:07
Severity ?
CWE
  • n/a
Summary
Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the time parameter at /goform/SetLEDCfg.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:07:34.528Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/CyberUnicornIoT/IoTvuln/blob/main/Tenda_ac9/1/tenda_ac9_SetLEDCfg.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the time parameter at /goform/SetLEDCfg."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-31T19:03:26",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/CyberUnicornIoT/IoTvuln/blob/main/Tenda_ac9/1/tenda_ac9_SetLEDCfg.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-36570",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the time parameter at /goform/SetLEDCfg."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/CyberUnicornIoT/IoTvuln/blob/main/Tenda_ac9/1/tenda_ac9_SetLEDCfg.md",
              "refsource": "MISC",
              "url": "https://github.com/CyberUnicornIoT/IoTvuln/blob/main/Tenda_ac9/1/tenda_ac9_SetLEDCfg.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-36570",
    "datePublished": "2022-08-31T19:03:26",
    "dateReserved": "2022-07-25T00:00:00",
    "dateUpdated": "2024-08-03T10:07:34.528Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-24543 (GCVE-0-2024-24543)
Vulnerability from cvelistv5
Published
2024-02-05 00:00
Modified
2025-05-15 19:47
Severity ?
CWE
  • n/a
Summary
Buffer Overflow vulnerability in the function setSchedWifi in Tenda AC9 v.3.0, firmware version v.15.03.06.42_multi allows a remote attacker to cause a denial of service or run arbitrary code via crafted overflow data.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T23:19:52.525Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/TimeSeg/IOT_CVE/blob/main/tenda/AC9V3/0130/setSchedWifi.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-24543",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-08T15:58:51.704481Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-787",
                "description": "CWE-787 Out-of-bounds Write",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-15T19:47:57.882Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Buffer Overflow vulnerability in the function setSchedWifi in Tenda AC9 v.3.0, firmware version v.15.03.06.42_multi allows a remote attacker to cause a denial of service or run arbitrary code via crafted overflow data."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-05T20:35:29.976Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/TimeSeg/IOT_CVE/blob/main/tenda/AC9V3/0130/setSchedWifi.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-24543",
    "datePublished": "2024-02-05T00:00:00.000Z",
    "dateReserved": "2024-01-25T00:00:00.000Z",
    "dateUpdated": "2025-05-15T19:47:57.882Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-45042 (GCVE-0-2025-45042)
Vulnerability from cvelistv5
Published
2025-05-05 00:00
Modified
2025-05-05 15:56
Severity ?
CWE
  • n/a
Summary
Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-45042",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-05T15:55:27.853789Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-78",
                "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-05T15:56:18.613Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/Ghostsuzhijian/Iot-/blob/main/ac9_telnetd/rx3_telnetd.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-05T15:32:23.717Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/Ghostsuzhijian/Iot-/blob/main/ac9_telnetd/rx3_telnetd.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-45042",
    "datePublished": "2025-05-05T00:00:00.000Z",
    "dateReserved": "2025-04-22T00:00:00.000Z",
    "dateUpdated": "2025-05-05T15:56:18.613Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25435 (GCVE-0-2022-25435)
Vulnerability from cvelistv5
Published
2022-03-18 20:53
Modified
2024-08-03 04:42
Severity ?
CWE
  • n/a
Summary
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetStaticRoutecfg function.
References
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:42:49.000Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/7"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetStaticRoutecfg function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-18T20:53:07",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/7"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-25435",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetStaticRoutecfg function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/7",
              "refsource": "MISC",
              "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/7"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-25435",
    "datePublished": "2022-03-18T20:53:07",
    "dateReserved": "2022-02-21T00:00:00",
    "dateUpdated": "2024-08-03T04:42:49.000Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-26278 (GCVE-0-2022-26278)
Vulnerability from cvelistv5
Published
2022-03-28 20:58
Modified
2024-08-03 04:56
Severity ?
CWE
  • n/a
Summary
Tenda AC9 v15.03.2.21_cn was discovered to contain a stack overflow via the time parameter in the PowerSaveSet function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:56:37.903Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/pllrry/Tenda-AC9-V15.03.2.21_cn-Command-Execution-Vulnerability/tree/main/Tenda-AC9"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 v15.03.2.21_cn was discovered to contain a stack overflow via the time parameter in the PowerSaveSet function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-28T20:58:32",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/pllrry/Tenda-AC9-V15.03.2.21_cn-Command-Execution-Vulnerability/tree/main/Tenda-AC9"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-26278",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC9 v15.03.2.21_cn was discovered to contain a stack overflow via the time parameter in the PowerSaveSet function."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/pllrry/Tenda-AC9-V15.03.2.21_cn-Command-Execution-Vulnerability/tree/main/Tenda-AC9",
              "refsource": "MISC",
              "url": "https://github.com/pllrry/Tenda-AC9-V15.03.2.21_cn-Command-Execution-Vulnerability/tree/main/Tenda-AC9"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-26278",
    "datePublished": "2022-03-28T20:58:32",
    "dateReserved": "2022-02-28T00:00:00",
    "dateUpdated": "2024-08-03T04:56:37.903Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-36273 (GCVE-0-2022-36273)
Vulnerability from cvelistv5
Published
2022-08-16 12:43
Modified
2024-08-03 10:00
Severity ?
CWE
  • n/a
Summary
Tenda AC9 V15.03.2.21_cn is vulnerable to command injection via goform/SetSysTimeCfg.
References
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:00:04.288Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/F0und-icu/CVEIDs/tree/main/TendaAC9"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC9 V15.03.2.21_cn is vulnerable to command injection via goform/SetSysTimeCfg."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-16T12:43:35",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/F0und-icu/CVEIDs/tree/main/TendaAC9"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-36273",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC9 V15.03.2.21_cn is vulnerable to command injection via goform/SetSysTimeCfg."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/F0und-icu/CVEIDs/tree/main/TendaAC9",
              "refsource": "MISC",
              "url": "https://github.com/F0und-icu/CVEIDs/tree/main/TendaAC9"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-36273",
    "datePublished": "2022-08-16T12:43:35",
    "dateReserved": "2022-07-18T00:00:00",
    "dateUpdated": "2024-08-03T10:00:04.288Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Vulnerability from fkie_nvd
Published
2024-02-22 23:15
Modified
2025-03-13 19:34
Summary
Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the formSetDeviceName function.
Impacted products
Vendor Product Version
tenda ac9_firmware 5.03.06.42_multi
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:5.03.06.42_multi:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4DB0137-7B0F-46BF-9178-83D695531170",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the formSetDeviceName function."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria en Tenda AC9 v.3.0 con versi\u00f3n de firmware v.15.03.06.42_multi permite a un atacante remoto ejecutar c\u00f3digo arbitrario a trav\u00e9s de la funci\u00f3n formSetDeviceName."
    }
  ],
  "id": "CVE-2024-25753",
  "lastModified": "2025-03-13T19:34:33.057",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-02-22T23:15:07.703",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://github.com/TimeSeg/IOT_CVE/blob/main/tenda/AC9V3/0218/formSetDeviceName.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://github.com/TimeSeg/IOT_CVE/blob/main/tenda/AC9V3/0218/formSetDeviceName.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-08-30 13:15
Modified
2024-11-21 08:21
Severity ?
Summary
Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter firewallEn at url /goform/SetFirewallCfg.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.06.42_multi
tenda ac9 3.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*",
              "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter firewallEn at url /goform/SetFirewallCfg."
    }
  ],
  "id": "CVE-2023-41560",
  "lastModified": "2024-11-21T08:21:17.953",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-08-30T13:15:14.390",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/peris-navince/founded-0-days/blob/main/formSetFirewallCfg/1.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/peris-navince/founded-0-days/blob/main/formSetFirewallCfg/1.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-06-09 22:15
Modified
2025-06-16 14:42
Summary
A vulnerability, which was classified as problematic, was found in Tenda AC9 15.03.02.13. This affects an unknown part. The manipulation leads to cross-site request forgery. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.2.13
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.13:*:*:*:*:*:*:*",
              "matchCriteriaId": "3473D6FD-4D42-46D0-9D96-F95D6D856E8E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability, which was classified as problematic, was found in Tenda AC9 15.03.02.13. This affects an unknown part. The manipulation leads to cross-site request forgery. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used."
    },
    {
      "lang": "es",
      "value": "Se encontr\u00f3 una vulnerabilidad clasificada como problem\u00e1tica en Tenda AC9 15.03.02.13. Esta afecta a una parte desconocida. La manipulaci\u00f3n provoca cross-site request forgery. Es posible iniciar el ataque de forma remota. Se ha hecho p\u00fablico el exploit y puede que sea utilizado."
    }
  ],
  "id": "CVE-2025-5900",
  "lastModified": "2025-06-16T14:42:41.297",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "cna@vuldb.com",
        "type": "Secondary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 1.4,
        "source": "cna@vuldb.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.1,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 4.2,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "PROOF_OF_CONCEPT",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "PASSIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "NONE",
          "vulnConfidentialityImpact": "NONE",
          "vulnIntegrityImpact": "LOW",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "cna@vuldb.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-06-09T22:15:22.790",
  "references": [
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://candle-throne-f75.notion.site/Tenda-AC9-fromSysToolReboot-20adf0aa1185806a9d20ee5c355c08a6?pvs=73"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://candle-throne-f75.notion.site/Tenda-AC9-fromSysToolRestoreSet-20adf0aa11858094a25ae21f9b4203da"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Permissions Required",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?ctiid.311673"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?id.311673"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?submit.592198"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?submit.592199"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Product"
      ],
      "url": "https://www.tenda.com.cn/"
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://candle-throne-f75.notion.site/Tenda-AC9-fromSysToolRestoreSet-20adf0aa11858094a25ae21f9b4203da"
    }
  ],
  "sourceIdentifier": "cna@vuldb.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-352"
        },
        {
          "lang": "en",
          "value": "CWE-862"
        }
      ],
      "source": "cna@vuldb.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-352"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-03-14 17:15
Modified
2025-03-19 19:15
Summary
In Tenda AC9 v1.0 V15.03.05.14_multi, the cloneType parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.05.14
tenda ac9 1.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.14:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA7503C5-02C6-4016-A4C6-414146719BFF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "566DA530-18FC-4A46-95B4-2A7D343A96A7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "In Tenda AC9 v1.0 V15.03.05.14_multi, the cloneType parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution."
    },
    {
      "lang": "es",
      "value": "En Tenda AC9 v1.0 V15.03.05.14_multi, el par\u00e1metro cloneType de /goform/AdvSetMacMtuWan tiene una vulnerabilidad de desbordamiento de pila, que puede conducir a la ejecuci\u00f3n remota de c\u00f3digo arbitrario."
    }
  ],
  "id": "CVE-2025-29385",
  "lastModified": "2025-03-19T19:15:49.280",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-03-14T17:15:52.393",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/shuqi233/loophole/blob/main/Tenda%20AC9/AdvSetMacMtuWan3.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-08-16 13:15
Modified
2024-11-21 07:12
Severity ?
Summary
Tenda AC9 V15.03.2.21_cn is vulnerable to command injection via goform/SetSysTimeCfg.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.2.21_cn
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.21_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "E2C7394F-9471-414D-B473-B0B87C63441C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 V15.03.2.21_cn is vulnerable to command injection via goform/SetSysTimeCfg."
    },
    {
      "lang": "es",
      "value": "Tenda AC9 versi\u00f3n V15.03.2.21_cn, es vulnerable a una inyecci\u00f3n de comandos por medio de goform/SetSysTimeCfg."
    }
  ],
  "id": "CVE-2022-36273",
  "lastModified": "2024-11-21T07:12:42.093",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-08-16T13:15:11.457",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/F0und-icu/CVEIDs/tree/main/TendaAC9"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/F0und-icu/CVEIDs/tree/main/TendaAC9"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2017-11-21 14:29
Modified
2025-04-20 01:37
Summary
Command Injection vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to execute arbitrary OS commands via a crafted cgi-bin/luci/usbeject?dev_name= GET request from the LAN. This occurs because the "sub_A6E8 usbeject_process_entry" function executes a system function with untrusted input.
Impacted products
Vendor Product Version
tenda ac9_firmware us_ac9v1.0br_v15.03.05.14_multi_td01
tenda ac9 -
tenda ac9_firmware ac9_kf_v15.03.05.19\(6318_\)_cn
tenda ac9 -
tenda ac15_firmware us_ac15v1.0br_v15.03.05.18_multi_td01
tenda ac15 -
tenda ac15_firmware us_ac15v1.0br_v15.03.05.19_multi_td01
tenda ac15 -
tenda ac18_firmware us_ac18v1.0br_v15.03.05.05_multi_td01
tenda ac18 -
tenda ac18_firmware ac18_kf_v15.03.05.19\(6318_\)_cn
tenda ac18 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:us_ac9v1.0br_v15.03.05.14_multi_td01:*:*:*:*:*:*:*",
              "matchCriteriaId": "A892AC99-F24B-4E0F-B3F0-CDBE1F4AD446",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:ac9_kf_v15.03.05.19\\(6318_\\)_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "512EB7D7-B12E-4219-8270-9EFCC8F6F366",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac15_firmware:us_ac15v1.0br_v15.03.05.18_multi_td01:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A51B455-6ABD-4827-B948-7341D353C05E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac15_firmware:us_ac15v1.0br_v15.03.05.19_multi_td01:*:*:*:*:*:*:*",
              "matchCriteriaId": "9535D5AC-FCE6-40A9-BA55-10DFE110BBBC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac18_firmware:us_ac18v1.0br_v15.03.05.05_multi_td01:*:*:*:*:*:*:*",
              "matchCriteriaId": "35D8463B-CC09-4C38-9881-4D7E3EC2B635",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac18_firmware:ac18_kf_v15.03.05.19\\(6318_\\)_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "72C6CF57-11B7-4A11-AA61-248ACAFE624C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Command Injection vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to execute arbitrary OS commands via a crafted cgi-bin/luci/usbeject?dev_name= GET request from the LAN. This occurs because the \"sub_A6E8 usbeject_process_entry\" function executes a system function with untrusted input."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de inyecci\u00f3n de comandos en app_data_center en dispositivos Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01 y Ac18 ac18_kf_V15.03.05.19(6318_)_cn permite que los atacantes remotos no autenticados ejecuten comandos de sistema operativo arbitrarios mediante una petici\u00f3n GET cgi-bin/luci/usbeject?dev_name= manipulada desde la red LAN. Esto ocurre porque la funci\u00f3n \"sub_A6E8 usbeject_process_entry\" ejecuta una funci\u00f3n del sistema con valores de entrada no fiables."
    }
  ],
  "id": "CVE-2017-16923",
  "lastModified": "2025-04-20T01:37:25.860",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 8.3,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 6.5,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2017-11-21T14:29:00.260",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Issue Tracking",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Iolop/Poc/tree/master/Router/Tenda"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Issue Tracking",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Iolop/Poc/tree/master/Router/Tenda"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-08-30 13:15
Modified
2024-11-21 08:21
Severity ?
Summary
Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter wpapsk_crypto at url /goform/WifiExtraSet.
Impacted products
Vendor Product Version
tenda ac9_firmware 5.03.06.42_multi
tenda ac9 3.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:5.03.06.42_multi:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4DB0137-7B0F-46BF-9178-83D695531170",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter wpapsk_crypto at url /goform/WifiExtraSet."
    }
  ],
  "id": "CVE-2023-41554",
  "lastModified": "2024-11-21T08:21:17.023",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-08-30T13:15:13.417",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetWirelessRepeat/1.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetWirelessRepeat/1.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-01-10 15:15
Modified
2025-04-09 18:35
Severity ?
Summary
Tenda ac9 v1.0 firmware v15.03.05.19 contains a stack overflow vulnerability in /goform/SetOnlineDevName, which may lead to remote arbitrary code execution.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.05.19
tenda ac9 1.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19:*:*:*:*:*:*:*",
              "matchCriteriaId": "C5731D5E-C98A-4AE8-B3AC-4703335628C1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "566DA530-18FC-4A46-95B4-2A7D343A96A7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda ac9 v1.0 firmware v15.03.05.19 contains a stack overflow vulnerability in /goform/SetOnlineDevName, which may lead to remote arbitrary code execution."
    },
    {
      "lang": "es",
      "value": "El firmware Tenda ac9 v1.0 v15.03.05.19 contiene una vulnerabilidad de desbordamiento de pila en /goform/SetOnlineDevName, que puede provocar la ejecuci\u00f3n remota de c\u00f3digo arbitrario."
    }
  ],
  "id": "CVE-2025-22946",
  "lastModified": "2025-04-09T18:35:44.810",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-01-10T15:15:16.710",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://noisy-caravel-a9a.notion.site/Tenda_AC9V1-0_V15-03-05-19_formSetDeviceName_sprintf_bof-16f898c94eac8057afcbceb63fda7d24"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-120"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Severity ?
Summary
An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. They allow remote code execution via shell metacharacters in the usbName field to the __fastcall function with a POST request.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.05.19\(6318\)_cn
tenda ac9 -
tenda ac15_firmware 15.03.05.19_cn
tenda ac15 -
tenda ac18_firmware 15.03.05.19\(6318\)_cn
tenda ac18 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. They allow remote code execution via shell metacharacters in the usbName field to the __fastcall function with a POST request."
    },
    {
      "lang": "es",
      "value": "Se ha descubierto un problema en dispositivos Tenda AC9 V15.03.05.19(6318)_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Permiten la ejecuci\u00f3n remota de c\u00f3digo mediante metacaracteres shell en el campo usbName en la funci\u00f3n __fastcall con una petici\u00f3n POST."
    }
  ],
  "id": "CVE-2018-18728",
  "lastModified": "2024-11-21T03:56:28.030",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-10-29T12:29:07.507",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/rce1.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/rce1.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-02-24 15:15
Modified
2024-11-21 06:52
Severity ?
Summary
Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the parameter NPTR.
Impacted products
Vendor Product Version
tenda ac9_firmware v15.03.2.21_cn
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:v15.03.2.21_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "42BB9C09-75A0-4E1A-BFDB-80836CC8F06B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the parameter NPTR."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que Tenda AC9 versi\u00f3n V15.03.2.21_cn, contiene un desbordamiento de pila por medio del par\u00e1metro NPTR"
    }
  ],
  "id": "CVE-2022-25414",
  "lastModified": "2024-11-21T06:52:09.483",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-24T15:15:31.860",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/1"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/1"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-07-14 00:15
Modified
2024-11-21 08:12
Severity ?
Summary
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:f1202_firmware:1.2.0.20\\(408\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "25D11FC4-85C7-4F6C-81A2-AF9CB6BE1507",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "37DF507C-5EDA-46A0-851E-ED8BC0B54F88",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1202_firmware:1.2.0.19_en:*:*:*:*:*:*:*",
              "matchCriteriaId": "C36B9BA7-B171-453D-951B-23CA2F19111A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1202:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A632A11-60A0-457C-A039-BED32F83BD52",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:f1202_firmware:1.0br:*:*:*:*:*:*:*",
              "matchCriteriaId": "83FA7DD8-061F-4893-ADBB-1FD1E6849107",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "37DF507C-5EDA-46A0-851E-ED8BC0B54F88",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac10_firmware:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "54F7AF9E-E4EC-4060-B1F4-29A891970DDE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac1206_firmware:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF48C35A-8042-4E7B-B672-8904B999E9AE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac7_firmware:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "FD539CFA-4D45-4776-9E62-66EB123456BC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac5_firmware:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A71BB02-CEFA-4B73-8B24-D4217C261D39",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0A74C4FD-76A0-4E7C-94E0-EC293F379DD2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7D1050F-CA28-4365-8C46-6D6AF7572EAA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient."
    }
  ],
  "id": "CVE-2023-37717",
  "lastModified": "2024-11-21T08:12:10.257",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-07-14T00:15:09.477",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromDhcpListClient/repot.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromDhcpListClient/repot.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-03-28 21:15
Modified
2024-11-21 06:53
Severity ?
Summary
Tenda AC9 v15.03.2.21_cn was discovered to contain a stack overflow via the time parameter in the PowerSaveSet function.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.2.21_cn
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.21_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "E2C7394F-9471-414D-B473-B0B87C63441C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 v15.03.2.21_cn was discovered to contain a stack overflow via the time parameter in the PowerSaveSet function."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que Tenda AC9 versi\u00f3n v15.03.2.21_cn, contiene un desbordamiento de pila por medio del par\u00e1metro time en la funci\u00f3n PowerSaveSet"
    }
  ],
  "id": "CVE-2022-26278",
  "lastModified": "2024-11-21T06:53:41.157",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-03-28T21:15:08.773",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/pllrry/Tenda-AC9-V15.03.2.21_cn-Command-Execution-Vulnerability/tree/main/Tenda-AC9"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/pllrry/Tenda-AC9-V15.03.2.21_cn-Command-Execution-Vulnerability/tree/main/Tenda-AC9"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-05-05 16:15
Modified
2025-05-07 16:39
Summary
Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.05.14
tenda ac9 1.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.14:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA7503C5-02C6-4016-A4C6-414146719BFF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "566DA530-18FC-4A46-95B4-2A7D343A96A7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function."
    },
    {
      "lang": "es",
      "value": "Se descubri\u00f3 que Tenda AC9 v15.03.05.14 conten\u00eda una vulnerabilidad de inyecci\u00f3n de comandos a trav\u00e9s de la funci\u00f3n Telnet."
    }
  ],
  "id": "CVE-2025-45042",
  "lastModified": "2025-05-07T16:39:20.990",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-05-05T16:15:51.410",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit"
      ],
      "url": "https://github.com/Ghostsuzhijian/Iot-/blob/main/ac9_telnetd/rx3_telnetd.md"
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "tags": [
        "Exploit"
      ],
      "url": "https://github.com/Ghostsuzhijian/Iot-/blob/main/ac9_telnetd/rx3_telnetd.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-03-18 21:15
Modified
2024-11-21 06:52
Severity ?
Summary
Tenda AC9 v15.03.2.21 was discovered to contain a buffer overflow via the time parameter in the saveparentcontrolinfo function.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.2.21
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.21:*:*:*:*:*:*:*",
              "matchCriteriaId": "929ABC94-0FC4-48BB-9666-B9682CB477B6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 v15.03.2.21 was discovered to contain a buffer overflow via the time parameter in the saveparentcontrolinfo function."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que Tenda AC9 versi\u00f3n v15.03.2.21, contiene un desbordamiento de b\u00fafer por medio del par\u00e1metro time en la funci\u00f3n saveparentcontrolinfo"
    }
  ],
  "id": "CVE-2022-25429",
  "lastModified": "2024-11-21T06:52:10.283",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-03-18T21:15:07.980",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/1"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/1"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-01-10 16:15
Modified
2025-04-09 18:36
Severity ?
Summary
Tenda ac9 v1.0 firmware v15.03.05.19 is vulnerable to command injection in /goform/SetSambaCfg, which may lead to remote arbitrary code execution.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.05.19
tenda ac9 1.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19:*:*:*:*:*:*:*",
              "matchCriteriaId": "C5731D5E-C98A-4AE8-B3AC-4703335628C1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "566DA530-18FC-4A46-95B4-2A7D343A96A7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda ac9 v1.0 firmware v15.03.05.19 is vulnerable to command injection in /goform/SetSambaCfg, which may lead to remote arbitrary code execution."
    },
    {
      "lang": "es",
      "value": "El firmware Tenda ac9 v1.0 v15.03.05.19 es vulnerable a la inyecci\u00f3n de comandos en /goform/SetSambaCfg, lo que puede provocar la ejecuci\u00f3n remota de c\u00f3digo arbitrario."
    }
  ],
  "id": "CVE-2025-22949",
  "lastModified": "2025-04-09T18:36:01.027",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-01-10T16:15:31.137",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://noisy-caravel-a9a.notion.site/Tenda_AC9V1-0_V15-03-05-19_formSetSambaConf_doSystemCmd_CI-16f898c94eac80d5801bdaf777ac2b27"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-07-14 00:15
Modified
2024-11-21 08:12
Severity ?
Summary
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:f1202_firmware:1.2.0.20\\(408\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "25D11FC4-85C7-4F6C-81A2-AF9CB6BE1507",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "37DF507C-5EDA-46A0-851E-ED8BC0B54F88",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1202_firmware:1.2.0.19_en:*:*:*:*:*:*:*",
              "matchCriteriaId": "C36B9BA7-B171-453D-951B-23CA2F19111A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1202:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A632A11-60A0-457C-A039-BED32F83BD52",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:f1202_firmware:1.0br:*:*:*:*:*:*:*",
              "matchCriteriaId": "83FA7DD8-061F-4893-ADBB-1FD1E6849107",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "37DF507C-5EDA-46A0-851E-ED8BC0B54F88",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac10_firmware:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "54F7AF9E-E4EC-4060-B1F4-29A891970DDE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac1206_firmware:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF48C35A-8042-4E7B-B672-8904B999E9AE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac7_firmware:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "FD539CFA-4D45-4776-9E62-66EB123456BC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac5_firmware:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A71BB02-CEFA-4B73-8B24-D4217C261D39",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0A74C4FD-76A0-4E7C-94E0-EC293F379DD2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7D1050F-CA28-4365-8C46-6D6AF7572EAA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting."
    }
  ],
  "id": "CVE-2023-37716",
  "lastModified": "2024-11-21T08:12:10.067",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-07-14T00:15:09.430",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromNatStaticSetting/report.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromNatStaticSetting/report.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-05-03 16:15
Modified
2024-11-21 06:57
Severity ?
Summary
There is a stack overflow vulnerability in the goform/fast_setting_wifi_set function in the httpd service of Tenda ac9 15.03.2.21_cn router. An attacker can obtain a stable shell through a carefully constructed payload
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.2.21_cn
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.21_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "E2C7394F-9471-414D-B473-B0B87C63441C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "There is a stack overflow vulnerability in the goform/fast_setting_wifi_set function in the httpd service of Tenda ac9 15.03.2.21_cn router. An attacker can obtain a stable shell through a carefully constructed payload"
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de desbordamiento de pila en la funci\u00f3n goform/fast_setting_wifi_set del servicio httpd del router Tenda ac9 versi\u00f3n 15.03.2.21_cn. Un atacante puede obtener un shell estable mediante una carga \u00fatil cuidadosamente construida"
    }
  ],
  "id": "CVE-2022-28560",
  "lastModified": "2024-11-21T06:57:30.927",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-05-03T16:15:19.130",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/iot-firmeware/-Router-vulnerability/tree/main/Tenda%20AC9"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/iot-firmeware/-Router-vulnerability/tree/main/Tenda%20AC9"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-02-05 21:15
Modified
2025-05-15 20:15
Summary
Buffer Overflow vulnerability in the function setSchedWifi in Tenda AC9 v.3.0, firmware version v.15.03.06.42_multi allows a remote attacker to cause a denial of service or run arbitrary code via crafted overflow data.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.06.42_multi
tenda ac9 3.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*",
              "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Buffer Overflow vulnerability in the function setSchedWifi in Tenda AC9 v.3.0, firmware version v.15.03.06.42_multi allows a remote attacker to cause a denial of service or run arbitrary code via crafted overflow data."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de desbordamiento de b\u00fafer en la funci\u00f3n setSchedWifi en Tenda AC9 v.3.0, versi\u00f3n de firmware v.15.03.06.42_multi permite a un atacante remoto provocar una denegaci\u00f3n de servicio o ejecutar c\u00f3digo arbitrario a trav\u00e9s de datos de desbordamiento manipulados."
    }
  ],
  "id": "CVE-2024-24543",
  "lastModified": "2025-05-15T20:15:47.027",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-02-05T21:15:12.073",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/TimeSeg/IOT_CVE/blob/main/tenda/AC9V3/0130/setSchedWifi.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/TimeSeg/IOT_CVE/blob/main/tenda/AC9V3/0130/setSchedWifi.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-08-07 19:15
Modified
2024-11-21 08:14
Severity ?
Summary
Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function.
Impacted products
Vendor Product Version
tenda ac1206_firmware 15.03.06.23
tenda ac1206 -
tenda ac5_firmware 15.03.06.28
tenda ac5 1.0
tenda ac9_firmware 15.03.06.42_multi
tenda ac9 3.0
tenda ac8_firmware 16.03.34.06
tenda ac8 4.0
tenda ac10_firmware 16.03.10.13
tenda ac10 4.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*",
              "matchCriteriaId": "787A50A1-EDBC-44EB-8CF2-11C4FC63719D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*",
              "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F1C8715-D7B4-4D1A-9E90-079C72049332",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac10:4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "970AEBF4-2B32-4633-A75B-2D2C598C048D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function."
    }
  ],
  "id": "CVE-2023-38935",
  "lastModified": "2024-11-21T08:14:28.643",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-08-07T19:15:11.277",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetQosBand/README.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetQosBand/README.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'deviceList' parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
Impacted products
Vendor Product Version
tenda ac7_firmware 15.03.06.44_cn
tenda ac7 -
tenda ac9_firmware 15.03.05.19\(6318\)_cn
tenda ac9 -
tenda ac10_firmware 15.03.06.23_cn
tenda ac10 -
tenda ac15_firmware 15.03.05.19_cn
tenda ac15 -
tenda ac18_firmware 15.03.05.19\(6318\)_cn
tenda ac18 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA048307-E3FA-4868-81E2-489CBCD6D27F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "39FE2B83-C4C4-4A4B-9F40-A6E340F067A7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceList\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function."
    },
    {
      "lang": "es",
      "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router, httpd. Al procesar el par\u00e1metro deviceList para una petici\u00f3n POST, el valor se emplea directamente en una llamada strcpy a una variable local colocada en la pila, que sobrescribe la direcci\u00f3n de retorno de la funci\u00f3n."
    }
  ],
  "id": "CVE-2018-18727",
  "lastModified": "2024-11-21T03:56:27.863",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-10-29T12:29:07.400",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-10-23 14:15
Modified
2024-11-01 14:03
Summary
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Impacted products
Vendor Product Version
tenda ac15_firmware 15.03.05.18
tenda ac15_firmware 15.03.05.19
tenda ac15 -
tenda ac7_firmware 15.03.06.44
tenda ac7 -
tenda ac10u_firmware 15.03.06.48
tenda ac10u_firmware 15.03.06.49
tenda ac10u -
tenda ac500_firmware 1.0.0.14
tenda ac500_firmware 1.0.0.16
tenda ac500_firmware 2.0.1.9\(1307\)
tenda ac500 -
tenda ac18_firmware 15.03.05.05
tenda ac18_firmware 15.03.05.19\(6318\)
tenda ac18 -
tenda ac9_firmware 15.03.2.13
tenda ac9_firmware 15.03.05.14
tenda ac9_firmware 15.03.05.19\(6318\)
tenda ac9 1.0
tenda ac9_firmware 15.03.06.42
tenda ac9 3.0
tenda ac1206_firmware 15.03.06.23
tenda ac1206 -
tenda ac6_firmware 15.03.06.23
tenda ac6 2.0
tenda ac10_firmware 16.03.10.13
tenda ac10_firmware 16.03.10.20
tenda ac10 4.0
tenda ac10_firmware 16.03.48.19
tenda ac10_firmware 16.03.48.23
tenda ac10 5.0
tenda ac8_firmware 16.03.34.06
tenda ac8_firmware 16.03.34.09
tenda ac8 4.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*",
              "matchCriteriaId": "56881C41-A993-45CC-BAE6-E9DE17FA56E2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*",
              "matchCriteriaId": "A14A19EE-FB4E-4371-AC85-1401EB78B16D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C2AFD04-833D-4085-BAD6-32A2715FA785",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*",
              "matchCriteriaId": "0F101E88-BEA9-4017-9048-860DF3D1BBBC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac10u:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CDBE5E26-7967-4FDD-A29F-7740B29C4B8E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac500_firmware:1.0.0.14:*:*:*:*:*:*:*",
              "matchCriteriaId": "61BA4026-93A8-4D83-815E-397A2EC0A279",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:tenda:ac500_firmware:1.0.0.16:*:*:*:*:*:*:*",
              "matchCriteriaId": "816A7A37-5952-4B22-80F7-8CD09383E079",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "2F0EEFAB-B3B0-4C10-A712-7A35F5FD076E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "64192A8B-CC65-44EC-942B-CC16AADF0D69",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D5CB727-FC6B-4212-A61E-2888A0DADFB0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "3AC468E5-44D1-4B94-B308-C1025DB1BB7B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.13:*:*:*:*:*:*:*",
              "matchCriteriaId": "3473D6FD-4D42-46D0-9D96-F95D6D856E8E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.14:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA7503C5-02C6-4016-A4C6-414146719BFF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "D8F25141-8B57-463D-AB97-F52C0143973C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "566DA530-18FC-4A46-95B4-2A7D343A96A7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42:*:*:*:*:*:*:*",
              "matchCriteriaId": "5B0A5168-9E0C-43F7-BF7B-3943A3316CB8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*",
              "matchCriteriaId": "787A50A1-EDBC-44EB-8CF2-11C4FC63719D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*",
              "matchCriteriaId": "D82FD30C-AF3C-4E3B-B674-002A5C9ED09D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "E382AD7E-1450-40FC-AE9D-698B491805F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F1C8715-D7B4-4D1A-9E90-079C72049332",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.20:*:*:*:*:*:*:*",
              "matchCriteriaId": "A19C486B-52A3-4C3E-851D-F349E8E0A706",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac10:4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "970AEBF4-2B32-4633-A75B-2D2C598C048D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.48.19:*:*:*:*:*:*:*",
              "matchCriteriaId": "DABA74C0-297A-4372-B84D-00BA0D334318",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.48.23:*:*:*:*:*:*:*",
              "matchCriteriaId": "AC3020CA-7422-4B9A-AA7B-C2B1A03A4450",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac10:5.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "2BCFFBD6-3DAD-4FEA-9B5D-D7CBFC36572D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE69F412-6FC7-470D-BC7E-B3AAC6B4585F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
    },
    {
      "lang": "es",
      "value": "Se ha detectado una vulnerabilidad en Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 y AC1206 hasta 20241022. Se ha calificado como problem\u00e1tica. Este problema afecta a la funci\u00f3n websReadEvent del archivo /goform/GetIPTV. La manipulaci\u00f3n del argumento Content-Length provoca la desreferenciaci\u00f3n de puntero nulo. El ataque puede iniciarse de forma remota. El exploit se ha hecho p\u00fablico y puede utilizarse."
    }
  ],
  "id": "CVE-2024-10280",
  "lastModified": "2024-11-01T14:03:20.267",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 6.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "cna@vuldb.com",
        "type": "Secondary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "cna@vuldb.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.1,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "NONE",
          "vulnIntegrityImpact": "NONE",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "cna@vuldb.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-10-23T14:15:04.500",
  "references": [
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://github.com/JohenanLi/router_vuls/blob/main/websReadEvent/websReadEvent.md"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Permissions Required",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?ctiid.281555"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?id.281555"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?submit.426417"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Product"
      ],
      "url": "https://www.tenda.com.cn/"
    }
  ],
  "sourceIdentifier": "cna@vuldb.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-476"
        }
      ],
      "source": "cna@vuldb.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-03-18 21:15
Modified
2024-11-21 06:52
Severity ?
Summary
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetIpMacBind function.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.2.21
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.21:*:*:*:*:*:*:*",
              "matchCriteriaId": "929ABC94-0FC4-48BB-9666-B9682CB477B6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetIpMacBind function."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que Tenda AC9 versi\u00f3n v15.03.2.21, contiene un desbordamiento de pila por medio del par\u00e1metro list en la funci\u00f3n SetIpMacBind"
    }
  ],
  "id": "CVE-2022-25439",
  "lastModified": "2024-11-21T06:52:11.203",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-03-18T21:15:08.247",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/8"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/8"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-23 15:16
Modified
2025-04-30 13:51
Severity ?
Summary
In Tenda AC9 v1.0 with firmware V15.03.05.14_multi, the security parameter of /goform/WifiBasicSet has a stack overflow vulnerability, which can lead to remote arbitrary code execution.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.05.14_multi
tenda ac9 1.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.14_multi:*:*:*:*:*:*:*",
              "matchCriteriaId": "D1A7C986-BA06-44DB-A271-91B88853CA43",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "566DA530-18FC-4A46-95B4-2A7D343A96A7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "In Tenda AC9 v1.0 with firmware V15.03.05.14_multi, the security parameter of /goform/WifiBasicSet has a stack overflow vulnerability, which can lead to remote arbitrary code execution."
    },
    {
      "lang": "es",
      "value": "En Tenda AC9 v1.0 con firmware V15.03.05.14_multi, el par\u00e1metro de seguridad de /goform/WifiBasicSet tiene una vulnerabilidad de desbordamiento de pila, que puede conducir a la ejecuci\u00f3n remota de c\u00f3digo arbitrario."
    }
  ],
  "id": "CVE-2025-45427",
  "lastModified": "2025-04-30T13:51:20.023",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-23T15:16:00.880",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/shuqi233/loophole/blob/main/Tenda%20AC9/WifiBasicSet-security.md"
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/shuqi233/loophole/blob/main/Tenda%20AC9/WifiBasicSet-security.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-03-18 21:15
Modified
2024-11-21 06:52
Severity ?
Summary
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetVirtualServerCfg function.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.2.21
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.21:*:*:*:*:*:*:*",
              "matchCriteriaId": "929ABC94-0FC4-48BB-9666-B9682CB477B6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetVirtualServerCfg function."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que Tenda AC9 versi\u00f3n v15.03.2.21, contiene un desbordamiento de pila por medio del par\u00e1metro list en la funci\u00f3n SetVirtualServerCfg"
    }
  ],
  "id": "CVE-2022-25437",
  "lastModified": "2024-11-21T06:52:10.937",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-03-18T21:15:08.170",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/9"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/9"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2017-11-24 07:29
Modified
2025-04-20 01:37
Summary
Directory Traversal vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to read arbitrary files via a cgi-bin/luci/request?op=1&path= URI that uses directory traversal sequences after a /usb/ substring.
Impacted products
Vendor Product Version
tenda ac9_firmware us_ac9v1.0br_v15.03.05.14_multi_td01
tenda ac9 -
tenda ac9_firmware ac9_kf_v15.03.05.19\(6318_\)_cn
tenda ac9 -
tenda ac15_firmware us_ac15v1.0br_v15.03.05.18_multi_td01
tenda ac15 -
tenda ac15_firmware us_ac15v1.0br_v15.03.05.19_multi_td01
tenda ac15 -
tenda ac18_firmware us_ac18v1.0br_v15.03.05.05_multi_td01
tenda ac18 -
tenda ac18_firmware ac18_kf_v15.03.05.19\(6318_\)_cn
tenda ac18 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:us_ac9v1.0br_v15.03.05.14_multi_td01:*:*:*:*:*:*:*",
              "matchCriteriaId": "A892AC99-F24B-4E0F-B3F0-CDBE1F4AD446",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:ac9_kf_v15.03.05.19\\(6318_\\)_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "512EB7D7-B12E-4219-8270-9EFCC8F6F366",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac15_firmware:us_ac15v1.0br_v15.03.05.18_multi_td01:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A51B455-6ABD-4827-B948-7341D353C05E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac15_firmware:us_ac15v1.0br_v15.03.05.19_multi_td01:*:*:*:*:*:*:*",
              "matchCriteriaId": "9535D5AC-FCE6-40A9-BA55-10DFE110BBBC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac18_firmware:us_ac18v1.0br_v15.03.05.05_multi_td01:*:*:*:*:*:*:*",
              "matchCriteriaId": "35D8463B-CC09-4C38-9881-4D7E3EC2B635",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac18_firmware:ac18_kf_v15.03.05.19\\(6318_\\)_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "72C6CF57-11B7-4A11-AA61-248ACAFE624C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Directory Traversal vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to read arbitrary files via a cgi-bin/luci/request?op=1\u0026path= URI that uses directory traversal sequences after a /usb/ substring."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de salto de directorio en app_data_center en dispositivos Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01 y Ac18 ac18_kf_V15.03.05.19(6318_)_cn permite que atacantes remotos no autenticados lean archivos arbitrarios mediante un URI cgi-bin/luci/request?op=1path= que emplea secuencias de salto de directorio tras una subcadena /usb/."
    }
  ],
  "id": "CVE-2017-16936",
  "lastModified": "2025-04-20T01:37:25.860",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 3.3,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.5,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.0"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2017-11-24T07:29:00.350",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Issue Tracking",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Iolop/Poc/tree/master/Router/Tenda"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Issue Tracking",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Iolop/Poc/tree/master/Router/Tenda"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-08-31 20:15
Modified
2024-11-21 07:13
Summary
Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the time parameter at /goform/SetLEDCfg.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.05.19
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19:*:*:*:*:*:*:*",
              "matchCriteriaId": "C5731D5E-C98A-4AE8-B3AC-4703335628C1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the time parameter at /goform/SetLEDCfg."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que Tenda AC9 versi\u00f3n V15.03.05.19, conten\u00eda un desbordamiento de pila por medio del par\u00e1metro time en /goform/SetLEDCfg"
    }
  ],
  "id": "CVE-2022-36570",
  "lastModified": "2024-11-21T07:13:19.663",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-08-31T20:15:08.973",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/CyberUnicornIoT/IoTvuln/blob/main/Tenda_ac9/1/tenda_ac9_SetLEDCfg.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/CyberUnicornIoT/IoTvuln/blob/main/Tenda_ac9/1/tenda_ac9_SetLEDCfg.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-02-22 23:15
Modified
2025-03-13 19:34
Summary
A Stack Based Buffer Overflow vulnerability in tenda AC9 AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the fromSetIpMacBind function.
Impacted products
Vendor Product Version
tenda ac9_firmware 5.03.06.42_multi
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:5.03.06.42_multi:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4DB0137-7B0F-46BF-9178-83D695531170",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A Stack Based Buffer Overflow vulnerability in tenda AC9 AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the fromSetIpMacBind function."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria en tenda AC9 AC9 v.3.0 con versi\u00f3n de firmware v.15.03.06.42_multi permite a un atacante remoto ejecutar c\u00f3digo arbitrario a trav\u00e9s de la funci\u00f3n fromSetIpMacBind."
    }
  ],
  "id": "CVE-2024-25748",
  "lastModified": "2025-03-13T19:34:47.157",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-02-22T23:15:07.640",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://github.com/TimeSeg/IOT_CVE/blob/main/tenda/AC9V3/0218/fromSetIpMacBind.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://github.com/TimeSeg/IOT_CVE/blob/main/tenda/AC9V3/0218/fromSetIpMacBind.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-08-30 13:15
Modified
2024-11-21 08:21
Severity ?
Summary
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.06.42_multi
tenda ac9 3.0
tenda ac7_firmware 15.03.06.44
tenda ac7 1.0
tenda ac5_firmware 15.03.06.28
tenda ac5 1.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*",
              "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet."
    }
  ],
  "id": "CVE-2023-41562",
  "lastModified": "2024-11-21T08:21:18.267",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-08-30T13:15:14.573",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/peris-navince/founded-0-days/blob/main/setSmartPowerManagement/1.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/peris-navince/founded-0-days/blob/main/setSmartPowerManagement/1.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-02-11 19:15
Modified
2024-11-21 05:20
Severity ?
Summary
A vulnerability was discovered in Tenda AC9 v3.0 V15.03.06.42_multi and Tenda AC9 V1.0 V15.03.05.19(6318)_CN which allows for remote code execution via shell metacharacters in the guestuser field to the __fastcall function with a POST request.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.06.42_multi
tenda ac9 3.0
tenda ac9_firmware 15.03.05.19\(6318\)_cn
tenda ac9 1.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*",
              "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "566DA530-18FC-4A46-95B4-2A7D343A96A7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability was discovered in Tenda AC9 v3.0 V15.03.06.42_multi and Tenda AC9 V1.0 V15.03.05.19(6318)_CN which allows for remote code execution via shell metacharacters in the guestuser field to the __fastcall function with a POST request."
    },
    {
      "lang": "es",
      "value": "Se ha detectado una vulnerabilidad en Tenda AC9 versi\u00f3n v3.0 V15.03.06.42_multi y Tenda AC9 versi\u00f3n V1.0 V15.03.05.19(6318)_CN que permite una ejecuci\u00f3n de c\u00f3digo remota por medio de metacaracteres de shell en el campo guestuser a la funci\u00f3n __fastcall con una petici\u00f3n POST"
    }
  ],
  "id": "CVE-2020-26728",
  "lastModified": "2024-11-21T05:20:16.467",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-11T19:15:08.027",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Broken Link"
      ],
      "url": "https://github.com/Lyc-heng/Router/blob/main/Tenda/rce1.md"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Lyc-heng/routers/blob/a80b30bccfc9b76f3a4868ff28ad5ce2e0fca180/routers/rce1.md"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Lyc-heng/routers/blob/main/routers/rce1.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Broken Link"
      ],
      "url": "https://github.com/Lyc-heng/Router/blob/main/Tenda/rce1.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Lyc-heng/routers/blob/a80b30bccfc9b76f3a4868ff28ad5ce2e0fca180/routers/rce1.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Lyc-heng/routers/blob/main/routers/rce1.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-03-18 21:15
Modified
2024-11-21 06:52
Severity ?
Summary
Tenda AC9 v15.03.2.21 was discovered to contain a remote command execution (RCE) vulnerability via the vlanid parameter in the SetIPTVCfg function.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.2.21
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.21:*:*:*:*:*:*:*",
              "matchCriteriaId": "929ABC94-0FC4-48BB-9666-B9682CB477B6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 v15.03.2.21 was discovered to contain a remote command execution (RCE) vulnerability via the vlanid parameter in the SetIPTVCfg function."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que Tenda AC9 versi\u00f3n v15.03.2.21, contiene una vulnerabilidad de Ejecuci\u00f3n de Comandos Remota (RCE) por medio del par\u00e1metro vlanid en la funci\u00f3n SetIPTVCfg"
    }
  ],
  "id": "CVE-2022-25441",
  "lastModified": "2024-11-21T06:52:11.467",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-03-18T21:15:08.323",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/12"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/12"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-04-25 20:29
Modified
2024-11-21 03:49
Summary
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router's web server (httpd). When processing the list parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B16592CE-98A8-478A-94E1-DF628ADE67E7",
              "versionEndIncluding": "15.03.06.44_cn",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "73D523BB-7EB3-4125-90C4-4C85F4AE1815",
              "versionEndIncluding": "15.03.05.19\\(6318\\)_cn",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9BDE03D1-5D87-4FCD-BB03-D483AB9BC186",
              "versionEndIncluding": "15.03.06.23_cn",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router\u0027s web server (httpd). When processing the list parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow."
    },
    {
      "lang": "es",
      "value": "Se descubri\u00f3 un problema en los dispositivos Tenda AC7 con firmware a trav\u00e9s de la versi\u00f3n V15.03.06.44_CN (AC7), dispositivos AC9 con firmware a trav\u00e9s de la versi\u00f3n V15.03.05.19 (6318) _CN (AC9), y dispositivos AC10 con firmware a trav\u00e9s de la versi\u00f3n V15.03.06.23_CN ( AC10). Existe una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router (httpd). Cuando son procesados los par\u00e1metros list para una solicitud post, el valor se escribe directamente con sprintf en una variable local colocada en la pila, que anula la direcci\u00f3n de retorno de la funci\u00f3n, lo que provoca un desbordamiento del b\u00fafer."
    }
  ],
  "id": "CVE-2018-14559",
  "lastModified": "2024-11-21T03:49:18.637",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-04-25T20:29:00.287",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-02/Tenda.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-02/Tenda.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-03-18 21:15
Modified
2024-11-21 06:52
Severity ?
Summary
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the firewallen parameter in the SetFirewallCfg function.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.2.21
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.21:*:*:*:*:*:*:*",
              "matchCriteriaId": "929ABC94-0FC4-48BB-9666-B9682CB477B6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the firewallen parameter in the SetFirewallCfg function."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que Tenda AC9 versi\u00f3n v15.03.2.21, contiene un desbordamiento de pila por medio del par\u00e1metro firewallen la funci\u00f3n SetFirewallCfg"
    }
  ],
  "id": "CVE-2022-25434",
  "lastModified": "2024-11-21T06:52:10.657",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-03-18T21:15:08.093",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/6"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/6"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-03-14 17:15
Modified
2025-03-17 19:51
Summary
In Tenda AC9 v1.0 V15.03.05.14_multi, the wanSpeed parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.05.14
tenda ac9 1.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.14:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA7503C5-02C6-4016-A4C6-414146719BFF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "566DA530-18FC-4A46-95B4-2A7D343A96A7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "In Tenda AC9 v1.0 V15.03.05.14_multi, the wanSpeed parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution."
    },
    {
      "lang": "es",
      "value": "En Tenda AC9 v1.0 V15.03.05.14_multi, el par\u00e1metro wanSpeed de /goform/AdvSetMacMtuWan tiene una vulnerabilidad de desbordamiento de pila, que puede conducir a la ejecuci\u00f3n remota de c\u00f3digo arbitrario."
    }
  ],
  "id": "CVE-2025-29387",
  "lastModified": "2025-03-17T19:51:04.180",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.1,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.1,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-03-14T17:15:52.720",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/shuqi233/loophole/blob/main/Tenda%20AC9/AdvSetMacMtuWan2.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-03-18 21:15
Modified
2024-11-21 06:52
Severity ?
Summary
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetStaticRoutecfg function.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.2.21
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.21:*:*:*:*:*:*:*",
              "matchCriteriaId": "929ABC94-0FC4-48BB-9666-B9682CB477B6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetStaticRoutecfg function."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que Tenda AC9 versi\u00f3n v15.03.2.21, contiene un desbordamiento de pila por medio del par\u00e1metro de lista en la funci\u00f3n SetStaticRoutecfg"
    }
  ],
  "id": "CVE-2022-25435",
  "lastModified": "2024-11-21T06:52:10.793",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-03-18T21:15:08.130",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/7"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/7"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-08-30 13:15
Modified
2024-11-21 08:21
Severity ?
Summary
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set.
Impacted products
Vendor Product Version
tenda ac9_firmware 5.03.06.42_multi
tenda ac9 3.0
tenda ac7_firmware 15.03.06.44
tenda ac7 1.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:5.03.06.42_multi:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4DB0137-7B0F-46BF-9178-83D695531170",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set."
    }
  ],
  "id": "CVE-2023-41552",
  "lastModified": "2024-11-21T08:21:16.707",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-08-30T13:15:13.087",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/peris-navince/founded-0-days/blob/main/form_fast_setting_wifi_set/1.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/peris-navince/founded-0-days/blob/main/form_fast_setting_wifi_set/1.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-04-25 20:29
Modified
2024-11-21 03:49
Summary
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router's web server (httpd). When processing the page parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, a causing buffer overflow.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B16592CE-98A8-478A-94E1-DF628ADE67E7",
              "versionEndIncluding": "15.03.06.44_cn",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "73D523BB-7EB3-4125-90C4-4C85F4AE1815",
              "versionEndIncluding": "15.03.05.19\\(6318\\)_cn",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9BDE03D1-5D87-4FCD-BB03-D483AB9BC186",
              "versionEndIncluding": "15.03.06.23_cn",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router\u0027s web server (httpd). When processing the page parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, a causing buffer overflow."
    },
    {
      "lang": "es",
      "value": "Se descubri\u00f3 un problema en los dispositivos Tenda AC7 con firmware a trav\u00e9s de la versi\u00f3n V15.03.06.44_CN (AC7), dispositivos AC9 con firmware a trav\u00e9s de la versi\u00f3n V15.03.05.19 (6318) _CN (AC9), y dispositivos AC10 con firmware a trav\u00e9s de la versi\u00f3n V15.03.06.23_CN ( AC10). Existe una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router (httpd). Cuando son procesados los par\u00e1metros page para una solicitud post, el valor se escribe directamente con sprintf hacia una variable local colocada en la pila, que anula la direcci\u00f3n de retorno de la funci\u00f3n, lo que provoca un desbordamiento del b\u00fafer."
    }
  ],
  "id": "CVE-2018-14557",
  "lastModified": "2024-11-21T03:49:18.313",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-04-25T20:29:00.240",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-03/Tenda.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-03/Tenda.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-08-07 19:15
Modified
2024-11-21 08:14
Severity ?
Summary
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function.
Impacted products
Vendor Product Version
tenda ac10_firmware 15.03.06.23
tenda ac10 1.0
tenda ac1206_firmware 15.03.06.23
tenda ac1206 -
tenda ac8_firmware 16.03.34.06
tenda ac8 4.0
tenda ac6_firmware 15.03.06.23
tenda ac6 2.0
tenda ac7_firmware 15.03.06.44
tenda ac7 1.0
tenda ac5_firmware 15.03.06.28
tenda ac5 1.0
tenda ac10_firmware 16.03.10.13
tenda ac10 4.0
tenda ac9_firmware 15.03.06.42_multi
tenda ac9 3.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23:*:*:*:*:*:*:*",
              "matchCriteriaId": "66ED84F0-B0EB-4F55-9AD6-C8B682BAB472",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac10:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF790B76-6CAD-483A-95FA-80955643825B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*",
              "matchCriteriaId": "787A50A1-EDBC-44EB-8CF2-11C4FC63719D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*",
              "matchCriteriaId": "D82FD30C-AF3C-4E3B-B674-002A5C9ED09D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "E382AD7E-1450-40FC-AE9D-698B491805F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F1C8715-D7B4-4D1A-9E90-079C72049332",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac10:4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "970AEBF4-2B32-4633-A75B-2D2C598C048D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*",
              "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function."
    }
  ],
  "id": "CVE-2023-38937",
  "lastModified": "2024-11-21T08:14:28.943",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-08-07T19:15:11.413",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetVirtualSer/README.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetVirtualSer/README.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-03-18 21:15
Modified
2024-11-21 06:52
Severity ?
Summary
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the urls parameter in the saveparentcontrolinfo function.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.2.21
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.21:*:*:*:*:*:*:*",
              "matchCriteriaId": "929ABC94-0FC4-48BB-9666-B9682CB477B6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the urls parameter in the saveparentcontrolinfo function."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que Tenda AC9 versi\u00f3n v15.03.2.21, contiene un desbordamiento de pila por medio del par\u00e1metro urls en la funci\u00f3n saveparentcontrolinfo"
    }
  ],
  "id": "CVE-2022-25433",
  "lastModified": "2024-11-21T06:52:10.540",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-03-18T21:15:08.057",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/5"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/5"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-23 15:16
Modified
2025-04-30 16:12
Severity ?
Summary
In Tenda ac9 v1.0 with firmware V15.03.05.14_multi, the rebootTime parameter of /goform/SetSysAutoRebbotCfg has a stack overflow vulnerability, which can lead to remote arbitrary code execution.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.05.14_multi
tenda ac9 1.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.14_multi:*:*:*:*:*:*:*",
              "matchCriteriaId": "D1A7C986-BA06-44DB-A271-91B88853CA43",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "566DA530-18FC-4A46-95B4-2A7D343A96A7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "In Tenda ac9 v1.0 with firmware V15.03.05.14_multi, the rebootTime parameter of /goform/SetSysAutoRebbotCfg has a stack overflow vulnerability, which can lead to remote arbitrary code execution."
    },
    {
      "lang": "es",
      "value": "En Tenda ac9 v1.0 con firmware V15.03.05.14_multi, el par\u00e1metro rebootTime de /goform/SetSysAutoRebbotCfg tiene una vulnerabilidad de desbordamiento de pila, que puede conducir a la ejecuci\u00f3n remota de c\u00f3digo arbitrario."
    }
  ],
  "id": "CVE-2025-45428",
  "lastModified": "2025-04-30T16:12:11.190",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-23T15:16:00.970",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/shuqi233/loophole/blob/main/Tenda%20AC9/SetSysAutoRebbotCfg-rebootTime.md"
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/shuqi233/loophole/blob/main/Tenda%20AC9/SetSysAutoRebbotCfg-rebootTime.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-03-18 21:15
Modified
2024-11-21 06:52
Severity ?
Summary
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the deviceId parameter in the saveparentcontrolinfo function.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.2.21
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.21:*:*:*:*:*:*:*",
              "matchCriteriaId": "929ABC94-0FC4-48BB-9666-B9682CB477B6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the deviceId parameter in the saveparentcontrolinfo function."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que Tenda AC9 versi\u00f3n v15.03.2.21, contiene un desbordamiento de pila por medio del par\u00e1metro deviceId en la funci\u00f3n saveparentcontrolinfo"
    }
  ],
  "id": "CVE-2022-25428",
  "lastModified": "2024-11-21T06:52:10.150",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-03-18T21:15:07.943",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/3"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/3"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-02-26 22:15
Modified
2025-03-13 19:34
Severity ?
Summary
A Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the fromSetSysTime function.
Impacted products
Vendor Product Version
tenda ac9_firmware 5.03.06.42_multi
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:5.03.06.42_multi:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4DB0137-7B0F-46BF-9178-83D695531170",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the fromSetSysTime function."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria en Tenda AC9 v.3.0 con versi\u00f3n de firmware v.15.03.06.42_multi permite a un atacante remoto ejecutar c\u00f3digo arbitrario a trav\u00e9s de la funci\u00f3n fromSetSysTime."
    }
  ],
  "id": "CVE-2024-25751",
  "lastModified": "2025-03-13T19:34:02.767",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-02-26T22:15:07.053",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://github.com/TimeSeg/IOT_CVE/blob/main/tenda/AC9V3/0218/fromSetSysTime.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://github.com/TimeSeg/IOT_CVE/blob/main/tenda/AC9V3/0218/fromSetSysTime.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-03-14 17:15
Modified
2025-03-19 19:15
Summary
In Tenda AC9 v1.0 V15.03.05.14_multi, the wanMTU parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.05.14
tenda ac9 1.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.14:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA7503C5-02C6-4016-A4C6-414146719BFF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "566DA530-18FC-4A46-95B4-2A7D343A96A7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "In Tenda AC9 v1.0 V15.03.05.14_multi, the wanMTU parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution."
    },
    {
      "lang": "es",
      "value": "En Tenda AC9 v1.0 V15.03.05.14_multi, el par\u00e1metro wanMTU de /goform/AdvSetMacMtuWan tiene una vulnerabilidad de desbordamiento de pila, que puede conducir a la ejecuci\u00f3n remota de c\u00f3digo arbitrario."
    }
  ],
  "id": "CVE-2025-29384",
  "lastModified": "2025-03-19T19:15:49.133",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-03-14T17:15:52.230",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/shuqi233/loophole/blob/main/Tenda%20AC9/AdvSetMacMtuWan1.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-08-30 13:15
Modified
2024-11-21 08:21
Severity ?
Summary
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.06.42_multi
tenda ac9 3.0
tenda ac7_firmware 15.03.06.44
tenda ac7 1.0
tenda ac5_firmware 15.03.06.28
tenda ac5 1.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*",
              "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting."
    }
  ],
  "id": "CVE-2023-41559",
  "lastModified": "2024-11-21T08:21:17.803",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-08-30T13:15:14.280",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromNatStaticSetting/1.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromNatStaticSetting/1.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-08-31 20:15
Modified
2024-11-21 07:13
Summary
Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the list parameter at /goform/setPptpUserList.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.05.19
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19:*:*:*:*:*:*:*",
              "matchCriteriaId": "C5731D5E-C98A-4AE8-B3AC-4703335628C1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the list parameter at /goform/setPptpUserList."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que Tenda AC9 versi\u00f3n V15.03.05.19, contiene un desbordamiento de pila por medio del par\u00e1metro list en /goform/setPptpUserList"
    }
  ],
  "id": "CVE-2022-36568",
  "lastModified": "2024-11-21T07:13:19.350",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-08-31T20:15:08.883",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/CyberUnicornIoT/IoTvuln/blob/main/Tenda_ac9/3/tenda_ac9_setPptpUserList.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/CyberUnicornIoT/IoTvuln/blob/main/Tenda_ac9/3/tenda_ac9_setPptpUserList.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "firewallEn" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
Impacted products
Vendor Product Version
tenda ac7_firmware 15.03.06.44_cn
tenda ac7 -
tenda ac9_firmware 15.03.05.19\(6318\)_cn
tenda ac9 -
tenda ac10_firmware 15.03.06.23_cn
tenda ac10 -
tenda ac15_firmware 15.03.05.19_cn
tenda ac15 -
tenda ac18_firmware 15.03.05.19\(6318\)_cn
tenda ac18 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA048307-E3FA-4868-81E2-489CBCD6D27F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "39FE2B83-C4C4-4A4B-9F40-A6E340F067A7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"firewallEn\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function."
    },
    {
      "lang": "es",
      "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router, httpd. Al procesar el par\u00e1metro firewallEn para una petici\u00f3n POST, el valor se emplea directamente en una llamada strcpy a una variable local colocada en la pila, que sobrescribe la direcci\u00f3n de retorno de la funci\u00f3n."
    }
  ],
  "id": "CVE-2018-18709",
  "lastModified": "2024-11-21T03:56:25.177",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-10-29T12:29:05.727",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-08-16 16:15
Modified
2025-04-11 15:13
Severity ?
Summary
A Command Injection vulnerability exists in formWriteFacMac of the httpd binary in Tenda AC9 v15.03.06.42. As a result, attacker can execute OS commands with root privileges.
References
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.06.42
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42:*:*:*:*:*:*:*",
              "matchCriteriaId": "5B0A5168-9E0C-43F7-BF7B-3943A3316CB8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A Command Injection vulnerability exists in formWriteFacMac of the httpd binary in Tenda AC9 v15.03.06.42. As a result, attacker can execute OS commands with root privileges."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad de inyecci\u00f3n de comandos en formWriteFacMac del binario httpd en Tenda AC9 v15.03.06.42. Como resultado, el atacante puede ejecutar comandos del sistema operativo con privilegios de superusuario."
    }
  ],
  "id": "CVE-2024-42634",
  "lastModified": "2025-04-11T15:13:25.360",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-08-16T16:15:06.670",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/goldds96/Report/blob/main/Tenda/AC9/CI.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-94"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-02-24 15:15
Modified
2024-11-21 06:52
Severity ?
Summary
Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function saveparentcontrolinfo.
Impacted products
Vendor Product Version
tenda ac9_firmware v15.03.2.21_cn
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:v15.03.2.21_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "42BB9C09-75A0-4E1A-BFDB-80836CC8F06B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function saveparentcontrolinfo."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que Tenda AC9 versi\u00f3n V15.03.2.21_cn, contiene un desbordamiento de pila por medio de la funci\u00f3n saveparentcontrolinfo"
    }
  ],
  "id": "CVE-2022-25417",
  "lastModified": "2024-11-21T06:52:09.623",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-24T15:15:31.900",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/3"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/3"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-08-31 20:15
Modified
2024-11-21 07:13
Summary
Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the deviceList parameter at /goform/setMacFilterCfg.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.05.19
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19:*:*:*:*:*:*:*",
              "matchCriteriaId": "C5731D5E-C98A-4AE8-B3AC-4703335628C1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the deviceList parameter at /goform/setMacFilterCfg."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que Tenda AC9 versi\u00f3n V15.03.05.19, conten\u00eda un desbordamiento de pila por el par\u00e1metro deviceList en /goform/setMacFilterCfg"
    }
  ],
  "id": "CVE-2022-36569",
  "lastModified": "2024-11-21T07:13:19.510",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-08-31T20:15:08.927",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/CyberUnicornIoT/IoTvuln/blob/main/Tenda_ac9/4/tenda_ac9_setMacFilterCfg.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/CyberUnicornIoT/IoTvuln/blob/main/Tenda_ac9/4/tenda_ac9_setMacFilterCfg.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-03-18 21:15
Modified
2024-11-21 06:52
Severity ?
Summary
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the ntpserver parameter in the SetSysTimeCfg function.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.2.21
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.21:*:*:*:*:*:*:*",
              "matchCriteriaId": "929ABC94-0FC4-48BB-9666-B9682CB477B6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the ntpserver parameter in the SetSysTimeCfg function."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que Tenda AC9 versi\u00f3n v15.03.2.21, contiene un desbordamiento de pila por medio del par\u00e1metro ntpserver en la funci\u00f3n SetSysTimeCfg"
    }
  ],
  "id": "CVE-2022-25440",
  "lastModified": "2024-11-21T06:52:11.337",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-03-18T21:15:08.283",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/13"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/13"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-08-07 19:15
Modified
2024-11-21 08:14
Severity ?
Summary
Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.
Impacted products
Vendor Product Version
tenda ac7_firmware 15.03.06.44
tenda ac7 1.0
tenda f1203_firmware 2.0.1.6
tenda f1203 -
tenda fh1205_firmware 2.0.0.7\(775\)
tenda fh1205 -
tenda ac5_firmware 15.03.06.28
tenda ac5 1.0
tenda ac9_firmware 15.03.06.42_multi
tenda ac9 3.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B3530E4-70D6-4246-84CA-E25797329DE0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0FB77DC8-C11D-418A-AB87-5FE0226CA6CA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "706158B7-6114-4AA8-A1A0-BB24119A3264",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E92D910-72BB-443F-9927-1E72AC8C8C9B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*",
              "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function."
    }
  ],
  "id": "CVE-2023-38930",
  "lastModified": "2024-11-21T08:14:27.803",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-08-07T19:15:10.907",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/addWifiMacFilter/README.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/addWifiMacFilter/README.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-08-07 19:15
Modified
2024-11-21 08:14
Severity ?
Summary
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.
Impacted products
Vendor Product Version
tenda ac10_firmware 15.03.06.23
tenda ac10 1.0
tenda ac1206_firmware 15.03.06.23
tenda ac1206 -
tenda ac6_firmware 15.03.06.23
tenda ac6 2.0
tenda ac7_firmware 15.03.06.44
tenda ac7 1.0
tenda f1203_firmware 2.0.1.6
tenda f1203 -
tenda ac5_firmware 15.03.06.28
tenda ac5 1.0
tenda fh1203_firmware 2.0.1.6
tenda fh1203 -
tenda fh1205_firmware 2.0.0.7\(775\)
tenda fh1205 -
tenda ac9_firmware 15.03.06.42_multi
tenda ac9 3.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23:*:*:*:*:*:*:*",
              "matchCriteriaId": "66ED84F0-B0EB-4F55-9AD6-C8B682BAB472",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac10:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF790B76-6CAD-483A-95FA-80955643825B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*",
              "matchCriteriaId": "787A50A1-EDBC-44EB-8CF2-11C4FC63719D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*",
              "matchCriteriaId": "D82FD30C-AF3C-4E3B-B674-002A5C9ED09D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "E382AD7E-1450-40FC-AE9D-698B491805F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B3530E4-70D6-4246-84CA-E25797329DE0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0FB77DC8-C11D-418A-AB87-5FE0226CA6CA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1203_firmware:2.0.1.6:*:*:*:*:*:*:*",
              "matchCriteriaId": "E28AF51D-EBFB-4EC8-9FCB-C3DFAE1DBB2E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E7A0DCB-AC18-4F32-86E2-F2C2E9118A71",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "706158B7-6114-4AA8-A1A0-BB24119A3264",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E92D910-72BB-443F-9927-1E72AC8C8C9B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*",
              "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function."
    }
  ],
  "id": "CVE-2023-38933",
  "lastModified": "2024-11-21T08:14:28.333",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-08-07T19:15:11.133",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetClientState/README.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetClientState/README.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-08-31 20:15
Modified
2024-11-21 07:13
Summary
Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the mask parameter at /goform/WanParameterSetting.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.05.19
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19:*:*:*:*:*:*:*",
              "matchCriteriaId": "C5731D5E-C98A-4AE8-B3AC-4703335628C1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the mask parameter at /goform/WanParameterSetting."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que Tenda AC9 versi\u00f3n V15.03.05.19, contiene un desbordamiento de pila por medio del par\u00e1metro mask en /goform/WanParameterSetting"
    }
  ],
  "id": "CVE-2022-36571",
  "lastModified": "2024-11-21T07:13:19.837",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-08-31T20:15:09.020",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/CyberUnicornIoT/IoTvuln/blob/main/Tenda_ac9/2/tenda_ac9_WanParameterSetting.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/CyberUnicornIoT/IoTvuln/blob/main/Tenda_ac9/2/tenda_ac9_WanParameterSetting.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-03-01 15:29
Modified
2024-11-21 04:12
Severity ?
Summary
Stack-based Buffer Overflow in httpd on Tenda AC9 devices V15.03.05.14_EN allows remote attackers to cause a denial of service or possibly have unspecified other impact.
Impacted products
Vendor Product Version
tendacn ac9_firmware 15.03.05.14_en
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tendacn:ac9_firmware:15.03.05.14_en:*:*:*:*:*:*:*",
              "matchCriteriaId": "2174914C-39DA-4FA1-9322-F5EE2C531B31",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Stack-based Buffer Overflow in httpd on Tenda AC9 devices V15.03.05.14_EN allows remote attackers to cause a denial of service or possibly have unspecified other impact."
    },
    {
      "lang": "es",
      "value": "Desbordamiento de b\u00fafer basado en pila en httpd en dispositivos Tenda AC9 V15.03.05.14_EN permite que atacantes remotos provoquen una denegaci\u00f3n de servicio (DoS) u otro tipo de impacto sin especificar."
    }
  ],
  "id": "CVE-2018-7561",
  "lastModified": "2024-11-21T04:12:22.127",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-03-01T15:29:00.213",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/VulDetailsPublication/Poc/tree/master/Tenda/AC9"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/VulDetailsPublication/Poc/tree/master/Tenda/AC9"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-05-02 15:15
Modified
2025-05-27 14:21
Severity ?
Summary
Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formsetUsbUnload function via the deviceName parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.06.42_multi
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*",
              "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formsetUsbUnload function via the deviceName parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 que Tenda AC9 V15.03.06.42_multi contiene una vulnerabilidad de inyecci\u00f3n de comandos en la funci\u00f3n formsetUsbUnload mediante el par\u00e1metro deviceName. Esta vulnerabilidad permite a los atacantes ejecutar comandos arbitrarios mediante una solicitud manipulada."
    }
  ],
  "id": "CVE-2025-44872",
  "lastModified": "2025-05-27T14:21:40.517",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-05-02T15:15:49.227",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Summermu/VulnForIoT/tree/main/Tenda_AC/AC9_formsetUsbUnload"
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Summermu/VulnForIoT/tree/main/Tenda_AC/AC9_formsetUsbUnload"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-06-07 14:15
Modified
2025-06-09 19:07
Summary
A vulnerability was found in Tenda AC9 15.03.02.13. It has been rated as critical. This issue affects the function formSetIptv of the file /goform/SetIPTVCfg of the component POST Request Handler. The manipulation of the argument list leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.2.13
tenda ac9 1.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.13:*:*:*:*:*:*:*",
              "matchCriteriaId": "3473D6FD-4D42-46D0-9D96-F95D6D856E8E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "566DA530-18FC-4A46-95B4-2A7D343A96A7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability was found in Tenda AC9 15.03.02.13. It has been rated as critical. This issue affects the function formSetIptv of the file /goform/SetIPTVCfg of the component POST Request Handler. The manipulation of the argument list leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
    },
    {
      "lang": "es",
      "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC9 15.03.02.13. Se ha clasificado como cr\u00edtica. Este problema afecta a la funci\u00f3n formSetIptv del archivo /goform/SetIPTVCfg del componente POST Request Handler. La manipulaci\u00f3n de la lista de argumentos provoca la inyecci\u00f3n de comandos. El ataque puede ejecutarse en remoto. Se ha hecho p\u00fablico el exploit y puede que sea utilizado."
    }
  ],
  "id": "CVE-2025-5836",
  "lastModified": "2025-06-09T19:07:49.417",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "cna@vuldb.com",
        "type": "Secondary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 6.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.4,
        "source": "cna@vuldb.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "PROOF_OF_CONCEPT",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "LOW",
          "vulnConfidentialityImpact": "LOW",
          "vulnIntegrityImpact": "LOW",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "cna@vuldb.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-06-07T14:15:22.500",
  "references": [
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://candle-throne-f75.notion.site/Tenda-AC9-formSetIptv-209df0aa11858061ae2bcbf83918d034"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Permissions Required"
      ],
      "url": "https://vuldb.com/?ctiid.311579"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?id.311579"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?submit.591363"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Product"
      ],
      "url": "https://www.tenda.com.cn/"
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://candle-throne-f75.notion.site/Tenda-AC9-formSetIptv-209df0aa11858061ae2bcbf83918d034"
    }
  ],
  "sourceIdentifier": "cna@vuldb.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-74"
        },
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "cna@vuldb.com",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'ntpServer' parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
Impacted products
Vendor Product Version
tenda ac7_firmware 15.03.06.44_cn
tenda ac7 -
tenda ac9_firmware 15.03.05.19\(6318\)_cn
tenda ac9 -
tenda ac10_firmware 15.03.06.23_cn
tenda ac10 -
tenda ac15_firmware 15.03.05.19_cn
tenda ac15 -
tenda ac18_firmware 15.03.05.19\(6318\)_cn
tenda ac18 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA048307-E3FA-4868-81E2-489CBCD6D27F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "39FE2B83-C4C4-4A4B-9F40-A6E340F067A7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027ntpServer\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function."
    },
    {
      "lang": "es",
      "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router, httpd. Al procesar el par\u00e1metro ntpServer para una petici\u00f3n POST, el valor se emplea directamente en una llamada strcpy a una variable local colocada en la pila, que sobrescribe la direcci\u00f3n de retorno de la funci\u00f3n."
    }
  ],
  "id": "CVE-2018-18732",
  "lastModified": "2024-11-21T03:56:28.703",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-10-29T12:29:07.960",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-08-30 13:15
Modified
2024-11-21 08:21
Severity ?
Summary
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind.
Impacted products
Vendor Product Version
tenda ac9_firmware 5.03.06.42_multi
tenda ac9 3.0
tenda ac7_firmware 15.03.06.44
tenda ac7 1.0
tenda ac5_firmware 15.03.06.28
tenda ac5 1.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:5.03.06.42_multi:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4DB0137-7B0F-46BF-9178-83D695531170",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind."
    }
  ],
  "id": "CVE-2023-41556",
  "lastModified": "2024-11-21T08:21:17.330",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-08-30T13:15:13.697",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetIpMacBind/1.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetIpMacBind/1.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-10-30 18:29
Modified
2025-03-20 21:03
Summary
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input.
Impacted products



{
  "cisaActionDue": "2022-05-03",
  "cisaExploitAdd": "2021-11-03",
  "cisaRequiredAction": "Apply updates per vendor instructions.",
  "cisaVulnerabilityName": "Tenda AC7, AC9, and AC10 Routers Command Injection Vulnerability",
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B16592CE-98A8-478A-94E1-DF628ADE67E7",
              "versionEndIncluding": "15.03.06.44_cn",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "73D523BB-7EB3-4125-90C4-4C85F4AE1815",
              "versionEndIncluding": "15.03.05.19\\(6318\\)_cn",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9BDE03D1-5D87-4FCD-BB03-D483AB9BC186",
              "versionEndIncluding": "15.03.06.23_cn",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the \"formsetUsbUnload\" function executes a dosystemCmd function with untrusted input."
    },
    {
      "lang": "es",
      "value": "Se ha descubierto un problema en dispositivos Tenda AC7 con firmware hasta la versi\u00f3n V15.03.06.44_CN(AC7), dispositivos AC9 devices con firmware hasta la versi\u00f3n V15.03.05.19(6318)_CN(AC9) y dispositivos AC10 con firmware hasta la versi\u00f3n V15.03.06.23_CN(AC10). Una vulnerabilidad de inyecci\u00f3n de comandos permite que los atacantes ejecuten comandos arbitrarios del sistema operativo mediante una petici\u00f3n goform/setUsbUnload. Esto ocurre debido a que la funci\u00f3n \"formsetUsbUnload\" ejecuta una funci\u00f3n dosystemCmd con entradas no fiables."
    }
  ],
  "id": "CVE-2018-14558",
  "lastModified": "2025-03-20T21:03:53.180",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2018-10-30T18:29:00.580",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory",
        "Broken Link"
      ],
      "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory",
        "Broken Link"
      ],
      "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-02-22 23:15
Modified
2025-03-13 19:34
Summary
A Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the formWifiBasicSet function.
Impacted products
Vendor Product Version
tenda ac9_firmware 5.03.06.42_multi
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:5.03.06.42_multi:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4DB0137-7B0F-46BF-9178-83D695531170",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the formWifiBasicSet function."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria en Tenda AC9 v.3.0 con versi\u00f3n de firmware v.15.03.06.42_multi permite a un atacante remoto ejecutar c\u00f3digo arbitrario a trav\u00e9s de la funci\u00f3n formWifiBasicSet."
    }
  ],
  "id": "CVE-2024-25756",
  "lastModified": "2025-03-13T19:34:21.237",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.0,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.1,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-02-22T23:15:07.750",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://github.com/TimeSeg/IOT_CVE/blob/main/tenda/AC9V3/0218/formWifiBasicSet.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://github.com/TimeSeg/IOT_CVE/blob/main/tenda/AC9V3/0218/formWifiBasicSet.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-06-08 14:15
Modified
2025-06-09 19:04
Summary
A vulnerability has been found in Tenda AC9 15.03.02.13 and classified as critical. Affected by this vulnerability is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg of the component HTTP POST Request Handler. The manipulation of the argument remoteIp leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.2.13
tenda ac9 1.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.13:*:*:*:*:*:*:*",
              "matchCriteriaId": "3473D6FD-4D42-46D0-9D96-F95D6D856E8E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "566DA530-18FC-4A46-95B4-2A7D343A96A7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been found in Tenda AC9 15.03.02.13 and classified as critical. Affected by this vulnerability is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg of the component HTTP POST Request Handler. The manipulation of the argument remoteIp leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
    },
    {
      "lang": "es",
      "value": "Se ha detectado una vulnerabilidad en Tenda AC9 15.03.02.13, clasificada como cr\u00edtica. Esta vulnerabilidad afecta a la funci\u00f3n formSetSafeWanWebMan del archivo /goform/SetRemoteWebCfg del componente HTTP POST Request Handler. La manipulaci\u00f3n del argumento remoteIp provoca un desbordamiento del b\u00fafer en la pila. El ataque puede ejecutarse en remoto. Se ha hecho p\u00fablico el exploit y puede que sea utilizado."
    }
  ],
  "id": "CVE-2025-5847",
  "lastModified": "2025-06-09T19:04:55.580",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "cna@vuldb.com",
        "type": "Secondary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "cna@vuldb.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.4,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "PROOF_OF_CONCEPT",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "cna@vuldb.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-06-08T14:15:21.097",
  "references": [
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://candle-throne-f75.notion.site/Tenda-AC9-formSetSafeWanWebMan-20adf0aa118580a29e80cef9109c947a"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Permissions Required"
      ],
      "url": "https://vuldb.com/?ctiid.311593"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?id.311593"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?submit.591362"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Product"
      ],
      "url": "https://www.tenda.com.cn/"
    }
  ],
  "sourceIdentifier": "cna@vuldb.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        },
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "cna@vuldb.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-04-07 16:15
Modified
2024-11-21 06:55
Severity ?
Summary
There is a stack overflow vulnerability in the SetSysTimeCfg() function in the httpd service of Tenda AC9 V15.03.2.21_cn. The attacker can obtain a stable root shell through a constructed payload.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.2.21_cn
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.21_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "E2C7394F-9471-414D-B473-B0B87C63441C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "There is a stack overflow vulnerability in the SetSysTimeCfg() function in the httpd service of Tenda AC9 V15.03.2.21_cn. The attacker can obtain a stable root shell through a constructed payload."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de desbordamiento de pila en la funci\u00f3n SetSysTimeCfg() del servicio httpd de Tenda AC9 versi\u00f3n V15.03.2.21_cn. El atacante puede obtener un shell de root estable mediante una carga \u00fatil construida"
    }
  ],
  "id": "CVE-2022-27022",
  "lastModified": "2024-11-21T06:55:00.767",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-04-07T16:15:07.667",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/14"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/14"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-08-30 13:15
Modified
2024-11-21 08:21
Severity ?
Summary
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.06.42_multi
tenda ac9 3.0
tenda ac5_firmware 15.03.06.28
tenda ac5 1.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*",
              "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo."
    }
  ],
  "id": "CVE-2023-41563",
  "lastModified": "2024-11-21T08:21:18.430",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-08-30T13:15:15.043",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/peris-navince/founded-0-days/blob/main/GetParentControlInfo/1.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/peris-navince/founded-0-days/blob/main/GetParentControlInfo/1.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-03-18 21:15
Modified
2024-11-21 06:52
Severity ?
Summary
Tenda AC9 v15.03.2.21 was discovered to contain a remote command execution (RCE) vulnerability via the SetIPTVCfg function.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.2.21
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.21:*:*:*:*:*:*:*",
              "matchCriteriaId": "929ABC94-0FC4-48BB-9666-B9682CB477B6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 v15.03.2.21 was discovered to contain a remote command execution (RCE) vulnerability via the SetIPTVCfg function."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que Tenda AC9 versi\u00f3n v15.03.2.21, contiene una vulnerabilidad de Ejecuci\u00f3n de Comandos Remota  (RCE) por medio de la funci\u00f3n SetIPTVCfg"
    }
  ],
  "id": "CVE-2022-25438",
  "lastModified": "2024-11-21T06:52:11.070",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-03-18T21:15:08.210",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/11"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/11"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-11-20 20:15
Modified
2025-06-10 14:15
Summary
Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd.
Impacted products
Vendor Product Version
tenda ac6_firmware 15.03.05.19\(6318\)
tenda ac6 2.0
tenda ac6_firmware 15.03.05.19\(6318\)
tenda ac6 1.0
tenda ac9_firmware 15.03.05.19\(6318\)
tenda ac9 1.0
tenda ac19_firmware 15.03.05.19\(6318\)
tenda ac19 1.0
tenda ac18_firmware 15.03.05.19\(6318\)
tenda ac18 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac6_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "1B4BD4F2-A420-407B-AB87-039E14C5B1ED",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "E382AD7E-1450-40FC-AE9D-698B491805F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac6_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "1B4BD4F2-A420-407B-AB87-039E14C5B1ED",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac6:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "B622BF6D-85E6-475A-B7FB-11BA1A641191",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "D8F25141-8B57-463D-AB97-F52C0143973C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "566DA530-18FC-4A46-95B4-2A7D343A96A7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac19_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "6A95D36D-4C22-4EDC-8CA9-D94C2838A9C9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac19:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2E477EC-CDE3-4BC4-8F1A-43C2AC3F6381",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "3AC468E5-44D1-4B94-B308-C1025DB1BB7B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de desbordamiento del b\u00fafer en Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 y v.1.0 permite a un atacante remoto ejecutar c\u00f3digo arbitrario a trav\u00e9s de la funci\u00f3n formSetCfm en bin/httpd."
    }
  ],
  "id": "CVE-2023-38823",
  "lastModified": "2025-06-10T14:15:25.570",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2023-11-20T20:15:07.357",
  "references": [
    {
      "source": "cve@mitre.org",
      "url": "https://github.com/johnathanhuutri/CVE_report/blob/master/CVE-2023-38823/README.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://github.com/johnathanhuutri/CVE_report/blob/master/CVE-2023-38823/README.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-120"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-120"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-08-30 13:15
Modified
2024-11-21 08:21
Severity ?
Summary
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg.
Impacted products
Vendor Product Version
tenda ac9_firmware 5.03.06.42_multi
tenda ac9 3.0
tenda ac5_firmware 15.03.06.28
tenda ac5 1.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:5.03.06.42_multi:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4DB0137-7B0F-46BF-9178-83D695531170",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg."
    }
  ],
  "id": "CVE-2023-41553",
  "lastModified": "2024-11-21T08:21:16.867",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-08-30T13:15:13.280",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetRouteStatic/1.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetRouteStatic/1.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-02-22 22:15
Modified
2025-03-13 19:34
Summary
Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the add_white_node function.
Impacted products
Vendor Product Version
tenda ac9_firmware 5.03.06.42_multi
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:5.03.06.42_multi:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4DB0137-7B0F-46BF-9178-83D695531170",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the add_white_node function."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria en Tenda AC9 v.3.0 con versi\u00f3n de firmware v.15.03.06.42_multi permite a un atacante remoto ejecutar c\u00f3digo arbitrario a trav\u00e9s de la funci\u00f3n add_white_node."
    }
  ],
  "id": "CVE-2024-25746",
  "lastModified": "2025-03-13T19:34:56.347",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-02-22T22:15:47.253",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://github.com/TimeSeg/IOT_CVE/blob/main/tenda/AC9V3/0218/add_white_node.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://github.com/TimeSeg/IOT_CVE/blob/main/tenda/AC9V3/0218/add_white_node.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-02-24 15:15
Modified
2024-11-21 06:52
Severity ?
Summary
Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function openSchedWifi.
Impacted products
Vendor Product Version
tenda ac9_firmware v15.03.2.21_cn
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:v15.03.2.21_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "42BB9C09-75A0-4E1A-BFDB-80836CC8F06B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function openSchedWifi."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que Tenda AC9 versi\u00f3n V15.03.2.21_cn, contiene un desbordamiento de pila por medio de la funci\u00f3n openSchedWifi"
    }
  ],
  "id": "CVE-2022-25418",
  "lastModified": "2024-11-21T06:52:09.750",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-24T15:15:31.940",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/2"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/2"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router's web server -- httpd. While processing the 'mac' parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow.
Impacted products
Vendor Product Version
tenda ac7_firmware 15.03.06.44_cn
tenda ac7 -
tenda ac9_firmware 15.03.05.19\(6318\)_cn
tenda ac9 -
tenda ac10_firmware 15.03.06.23_cn
tenda ac10 -
tenda ac15_firmware 15.03.05.19_cn
tenda ac15 -
tenda ac18_firmware 15.03.05.19\(6318\)_cn
tenda ac18 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA048307-E3FA-4868-81E2-489CBCD6D27F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "39FE2B83-C4C4-4A4B-9F40-A6E340F067A7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027mac\u0027 parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow."
    },
    {
      "lang": "es",
      "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de b\u00fafer basado en memoria din\u00e1mica (heap) en el servidor web del router, httpd. Al procesar el par\u00e1metro mac para una petici\u00f3n POST, el valor se emplea directamente en una llamada strcpy a una variable en el heap, que puede filtrar informaci\u00f3n sensible o secuestrar el flujo de control del programa."
    }
  ],
  "id": "CVE-2018-18729",
  "lastModified": "2024-11-21T03:56:28.197",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 8.5,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-10-29T12:29:07.617",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-03-18 21:15
Modified
2024-11-21 06:52
Severity ?
Summary
Tenda AC9 v15.03.2.21 was discovered to contain multiple stack overflows via the NPTR, V12, V10 and V11 parameter in the Formsetqosband function.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.2.21
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.21:*:*:*:*:*:*:*",
              "matchCriteriaId": "929ABC94-0FC4-48BB-9666-B9682CB477B6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 v15.03.2.21 was discovered to contain multiple stack overflows via the NPTR, V12, V10 and V11 parameter in the Formsetqosband function."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que Tenda AC9 versi\u00f3n v15.03.2.21, contiene m\u00faltiples desbordamientos de pila por medio de los par\u00e1metros NPTR, V12, V10 y V11 en la funci\u00f3n Formsetqosband"
    }
  ],
  "id": "CVE-2022-25431",
  "lastModified": "2024-11-21T06:52:10.413",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-03-18T21:15:08.017",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/4"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/4"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-05-24 12:15
Modified
2024-11-21 06:27
Summary
There is a buffer overflow vulnerability in the Web server httpd of the router in Tenda router devices such as Tenda AC9 V1.0 V15.03.02.19(6318) and Tenda AC9 V3.0 V15.03.06.42_multi. When setting the virtual service, the httpd program will crash and exit when the super-long list parameter occurs.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.05.19\(6318\)
tenda ac9 1.0
tenda ac9_firmware 15.03.06.42_multi
tenda ac9 3.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "D8F25141-8B57-463D-AB97-F52C0143973C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "566DA530-18FC-4A46-95B4-2A7D343A96A7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*",
              "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "There is a buffer overflow vulnerability in the Web server httpd of the router in Tenda router devices such as Tenda AC9 V1.0 V15.03.02.19(6318) and Tenda AC9 V3.0 V15.03.06.42_multi. When setting the virtual service, the httpd program will crash and exit when the super-long list parameter occurs."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web httpd del router en los dispositivos de router Tenda, como Tenda AC9 versi\u00f3n V1.0 V15.03.02.19(6318) y Tenda AC9 versi\u00f3n V3.0 V15.03.06.42_multi. Cuando es configurado el servicio virtual, el programa httpd es bloqueado y sale cuando es producido el par\u00e1metro de lista superlarga"
    }
  ],
  "id": "CVE-2021-42659",
  "lastModified": "2024-11-21T06:27:55.827",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 6.1,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 6.5,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-05-24T12:15:07.590",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Lyc-heng/routers/blob/main/routers/stack4.md"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.cnvd.org.cn/flaw/show/CNVD-2021-24948"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Lyc-heng/routers/blob/main/routers/stack4.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.cnvd.org.cn/flaw/show/CNVD-2021-24948"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-23 16:15
Modified
2025-04-30 15:48
Severity ?
Summary
In the Tenda ac9 v1.0 router with firmware V15.03.05.14_multi, there is a stack overflow vulnerability in /goform/WifiWpsStart, which may lead to remote arbitrary code execution.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.05.14_multi
tenda ac9 1.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.14_multi:*:*:*:*:*:*:*",
              "matchCriteriaId": "D1A7C986-BA06-44DB-A271-91B88853CA43",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "566DA530-18FC-4A46-95B4-2A7D343A96A7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "In the Tenda ac9 v1.0 router with firmware V15.03.05.14_multi, there is a stack overflow vulnerability in /goform/WifiWpsStart, which may lead to remote arbitrary code execution."
    },
    {
      "lang": "es",
      "value": "En el enrutador Tenda ac9 v1.0 con firmware V15.03.05.14_multi, hay una vulnerabilidad de desbordamiento de pila en /goform/WifiWpsStart, que puede provocar la ejecuci\u00f3n remota de c\u00f3digo arbitrario."
    }
  ],
  "id": "CVE-2025-45429",
  "lastModified": "2025-04-30T15:48:51.963",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-23T16:15:48.473",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/shuqi233/loophole/blob/main/Tenda%20AC9/WifiWpsStart-index.md"
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/shuqi233/loophole/blob/main/Tenda%20AC9/WifiWpsStart-index.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'deviceMac' parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
Impacted products
Vendor Product Version
tenda ac7_firmware 15.03.06.44_cn
tenda ac7 -
tenda ac9_firmware 15.03.05.19\(6318\)_cn
tenda ac9 -
tenda ac10_firmware 15.03.06.23_cn
tenda ac10 -
tenda ac15_firmware 15.03.05.19_cn
tenda ac15 -
tenda ac18_firmware 15.03.05.19\(6318\)_cn
tenda ac18 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA048307-E3FA-4868-81E2-489CBCD6D27F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "39FE2B83-C4C4-4A4B-9F40-A6E340F067A7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceMac\u0027 parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function."
    },
    {
      "lang": "es",
      "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router, httpd. Al procesar el par\u00e1metro deviceMac para una petici\u00f3n POST, el valor se emplea directamente en una llamada sprintf a una variable local colocada en la pila, que sobrescribe la direcci\u00f3n de retorno de la funci\u00f3n."
    }
  ],
  "id": "CVE-2018-18731",
  "lastModified": "2024-11-21T03:56:28.527",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-10-29T12:29:07.837",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-03-18 21:15
Modified
2024-11-21 06:52
Severity ?
Summary
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the schedendtime parameter in the openSchedWifi function.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.2.21
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.21:*:*:*:*:*:*:*",
              "matchCriteriaId": "929ABC94-0FC4-48BB-9666-B9682CB477B6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the schedendtime parameter in the openSchedWifi function."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que Tenda AC9 versi\u00f3n v15.03.2.21, contiene un desbordamiento de pila por medio del par\u00e1metro schedendtime en la funci\u00f3n openSchedWifi"
    }
  ],
  "id": "CVE-2022-25427",
  "lastModified": "2024-11-21T06:52:10.013",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-03-18T21:15:07.907",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/2"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/2"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-06-07 18:15
Modified
2025-06-09 19:07
Summary
A vulnerability, which was classified as critical, has been found in Tenda AC9 15.03.02.13. Affected by this issue is the function fromadvsetlanip of the file /goform/AdvSetLanip of the component POST Request Handler. The manipulation of the argument lanMask leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.2.13
tenda ac9 1.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.13:*:*:*:*:*:*:*",
              "matchCriteriaId": "3473D6FD-4D42-46D0-9D96-F95D6D856E8E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "566DA530-18FC-4A46-95B4-2A7D343A96A7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability, which was classified as critical, has been found in Tenda AC9 15.03.02.13. Affected by this issue is the function fromadvsetlanip of the file /goform/AdvSetLanip of the component POST Request Handler. The manipulation of the argument lanMask leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
    },
    {
      "lang": "es",
      "value": "Se ha detectado una vulnerabilidad clasificada como cr\u00edtica en Tenda AC9 15.03.02.13. Este problema afecta a la funci\u00f3n fromadvsetlanip del archivo /goform/AdvSetLanip del componente POST Request Handler. La manipulaci\u00f3n del argumento lanMask provoca un desbordamiento del b\u00fafer. El ataque puede ejecutarse en remoto. Se ha hecho p\u00fablico el exploit y puede que sea utilizado."
    }
  ],
  "id": "CVE-2025-5839",
  "lastModified": "2025-06-09T19:07:34.470",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "cna@vuldb.com",
        "type": "Secondary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "cna@vuldb.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.4,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "PROOF_OF_CONCEPT",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "cna@vuldb.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-06-07T18:15:25.080",
  "references": [
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://candle-throne-f75.notion.site/Tenda-AC9-fromadvsetlanip-20adf0aa11858027b7c3c2f4e44bb867"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Permissions Required"
      ],
      "url": "https://vuldb.com/?ctiid.311582"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?id.311582"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?submit.591369"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Product"
      ],
      "url": "https://www.tenda.com.cn/"
    }
  ],
  "sourceIdentifier": "cna@vuldb.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        },
        {
          "lang": "en",
          "value": "CWE-120"
        }
      ],
      "source": "cna@vuldb.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-08-07 19:15
Modified
2024-11-21 08:14
Severity ?
Summary
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
Impacted products
Vendor Product Version
tenda ac10_firmware 15.03.06.23
tenda ac10 1.0
tenda ac1206_firmware 15.03.06.23
tenda ac1206 -
tenda ac6_firmware 15.03.06.23
tenda ac6 2.0
tenda ac7_firmware 15.03.06.44
tenda ac7 1.0
tenda f1203_firmware 2.0.1.6
tenda f1203 -
tenda ac5_firmware 15.03.06.28
tenda ac5 1.0
tenda fh1203_firmware 2.0.1.6
tenda fh1203 -
tenda fh1205_firmware 2.0.0.7\(775\)
tenda fh1205 -
tenda ac9_firmware 15.03.06.42_multi
tenda ac9 3.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23:*:*:*:*:*:*:*",
              "matchCriteriaId": "66ED84F0-B0EB-4F55-9AD6-C8B682BAB472",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac10:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF790B76-6CAD-483A-95FA-80955643825B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*",
              "matchCriteriaId": "787A50A1-EDBC-44EB-8CF2-11C4FC63719D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*",
              "matchCriteriaId": "D82FD30C-AF3C-4E3B-B674-002A5C9ED09D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "E382AD7E-1450-40FC-AE9D-698B491805F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B3530E4-70D6-4246-84CA-E25797329DE0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0FB77DC8-C11D-418A-AB87-5FE0226CA6CA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1203_firmware:2.0.1.6:*:*:*:*:*:*:*",
              "matchCriteriaId": "E28AF51D-EBFB-4EC8-9FCB-C3DFAE1DBB2E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E7A0DCB-AC18-4F32-86E2-F2C2E9118A71",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*",
              "matchCriteriaId": "706158B7-6114-4AA8-A1A0-BB24119A3264",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E92D910-72BB-443F-9927-1E72AC8C8C9B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*",
              "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function."
    }
  ],
  "id": "CVE-2023-38936",
  "lastModified": "2024-11-21T08:14:28.797",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-08-07T19:15:11.343",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Vendor Advisory"
      ],
      "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetSpeedWan/README.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Vendor Advisory"
      ],
      "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetSpeedWan/README.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromAddressNat" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
Impacted products
Vendor Product Version
tenda ac7_firmware 15.03.06.44_cn
tenda ac7 -
tenda ac9_firmware 15.03.05.19\(6318\)_cn
tenda ac9 -
tenda ac10_firmware 15.03.06.23_cn
tenda ac10 -
tenda ac15_firmware 15.03.05.19_cn
tenda ac15 -
tenda ac18_firmware 15.03.05.19\(6318\)_cn
tenda ac18 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA048307-E3FA-4868-81E2-489CBCD6D27F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "39FE2B83-C4C4-4A4B-9F40-A6E340F067A7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromAddressNat\" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function."
    },
    {
      "lang": "es",
      "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router, httpd. Al procesar el par\u00e1metro page de la funci\u00f3n fromAddressNat para una petici\u00f3n POST, el valor se emplea directamente en una llamada sprintf a una variable local colocada en la pila, que sobrescribe la direcci\u00f3n de retorno de la funci\u00f3n."
    }
  ],
  "id": "CVE-2018-18708",
  "lastModified": "2024-11-21T03:56:25.030",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-10-29T12:29:05.617",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'startIp' and 'endIp' parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
Impacted products
Vendor Product Version
tenda ac7_firmware 15.03.06.44_cn
tenda ac7 -
tenda ac9_firmware 15.03.05.19\(6318\)_cn
tenda ac9 -
tenda ac10_firmware 15.03.06.23_cn
tenda ac10 -
tenda ac15_firmware 15.03.05.19_cn
tenda ac15 -
tenda ac18_firmware 15.03.05.19\(6318\)_cn
tenda ac18 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA048307-E3FA-4868-81E2-489CBCD6D27F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "39FE2B83-C4C4-4A4B-9F40-A6E340F067A7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027startIp\u0027 and \u0027endIp\u0027 parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function."
    },
    {
      "lang": "es",
      "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router, httpd. Al procesar los par\u00e1metros startIp y endIp para una petici\u00f3n POST, cada valor se emplea directamente en una llamada sprintf a una variable local colocada en la pila, que sobrescribe la direcci\u00f3n de retorno de la funci\u00f3n."
    }
  ],
  "id": "CVE-2018-18730",
  "lastModified": "2024-11-21T03:56:28.363",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-10-29T12:29:07.727",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-04-07 15:15
Modified
2024-11-21 06:55
Severity ?
Summary
There is a stack overflow vulnerability in the SetStaticRouteCfg() function in the httpd service of Tenda AC9 15.03.2.21_cn.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.2.21_cn
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.21_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "E2C7394F-9471-414D-B473-B0B87C63441C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "There is a stack overflow vulnerability in the SetStaticRouteCfg() function in the httpd service of Tenda AC9 15.03.2.21_cn."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de desbordamiento de pila en la funci\u00f3n SetStaticRouteCfg() del servicio httpd de Tenda AC9 versi\u00f3n 15.03.2.21_cn"
    }
  ],
  "id": "CVE-2022-27016",
  "lastModified": "2024-11-21T06:55:00.560",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-04-07T15:15:08.430",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/10"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/EPhaha/IOT_vuln/tree/main/Tenda/AC9/10"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-03-14 17:15
Modified
2025-03-19 19:15
Summary
In Tenda AC9 v1.0 V15.03.05.14_multi, the mac parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.05.14
tenda ac9 1.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.14:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA7503C5-02C6-4016-A4C6-414146719BFF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "566DA530-18FC-4A46-95B4-2A7D343A96A7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "In Tenda AC9 v1.0 V15.03.05.14_multi, the mac parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution."
    },
    {
      "lang": "es",
      "value": "En Tenda AC9 v1.0 V15.03.05.14_multi, el par\u00e1metro mac de /goform/AdvSetMacMtuWan tiene una vulnerabilidad de desbordamiento de pila, que puede conducir a la ejecuci\u00f3n remota de c\u00f3digo arbitrario."
    }
  ],
  "id": "CVE-2025-29386",
  "lastModified": "2025-03-19T19:15:49.423",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-03-14T17:15:52.557",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/shuqi233/loophole/blob/main/Tenda%20AC9/AdvSetMacMtuWan4.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromDhcpListClient" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
Impacted products
Vendor Product Version
tenda ac7_firmware 15.03.06.44_cn
tenda ac7 -
tenda ac9_firmware 15.03.05.19\(6318\)_cn
tenda ac9 -
tenda ac10_firmware 15.03.06.23_cn
tenda ac10 -
tenda ac15_firmware 15.03.05.19_cn
tenda ac15 -
tenda ac18_firmware 15.03.05.19\(6318\)_cn
tenda ac18 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA048307-E3FA-4868-81E2-489CBCD6D27F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "39FE2B83-C4C4-4A4B-9F40-A6E340F067A7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromDhcpListClient\" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function."
    },
    {
      "lang": "es",
      "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router, httpd. Al procesar el par\u00e1metro page de la funci\u00f3n fromDhcpListClient para una petici\u00f3n, se emplea directamente en una llamada sprintf a una variable local colocada en la pila, que sobrescribe la direcci\u00f3n de retorno de la funci\u00f3n."
    }
  ],
  "id": "CVE-2018-18706",
  "lastModified": "2024-11-21T03:56:24.723",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-10-29T12:29:05.400",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-05-02 15:15
Modified
2025-05-27 14:21
Severity ?
Summary
Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formSetSambaConf function via the usbname parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.06.42_multi
tenda ac9 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*",
              "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formSetSambaConf function via the usbname parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 que Tenda AC9 V15.03.06.42_multi conten\u00eda una vulnerabilidad de inyecci\u00f3n de comandos en la funci\u00f3n formSetSambaConf mediante el par\u00e1metro usbname. Esta vulnerabilidad permite a los atacantes ejecutar comandos arbitrarios mediante una solicitud manipulada."
    }
  ],
  "id": "CVE-2025-44877",
  "lastModified": "2025-05-27T14:21:50.710",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-05-02T15:15:49.323",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Summermu/VulnForIoT/tree/main/Tenda_AC/AC9_formSetSambaConf"
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Summermu/VulnForIoT/tree/main/Tenda_AC/AC9_formSetSambaConf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "ssid" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
Impacted products
Vendor Product Version
tenda ac7_firmware 15.03.06.44_cn
tenda ac7 -
tenda ac9_firmware 15.03.05.19\(6318\)_cn
tenda ac9 -
tenda ac10_firmware 15.03.06.23_cn
tenda ac10 -
tenda ac15_firmware 15.03.05.19_cn
tenda ac15 -
tenda ac18_firmware 15.03.05.19\(6318\)_cn
tenda ac18 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA048307-E3FA-4868-81E2-489CBCD6D27F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "39FE2B83-C4C4-4A4B-9F40-A6E340F067A7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*",
              "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"ssid\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function."
    },
    {
      "lang": "es",
      "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router, httpd. Al procesar el par\u00e1metro ssid para una petici\u00f3n POST, el valor se emplea directamente en una llamada strcpy a una variable local colocada en la pila, que sobrescribe la direcci\u00f3n de retorno de la funci\u00f3n."
    }
  ],
  "id": "CVE-2018-18707",
  "lastModified": "2024-11-21T03:56:24.870",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-10-29T12:29:05.507",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-08-30 13:15
Modified
2024-11-21 08:21
Severity ?
Summary
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg.
Impacted products
Vendor Product Version
tenda ac9_firmware 15.03.06.42_multi
tenda ac9 3.0
tenda ac5_firmware 15.03.06.28
tenda ac5 1.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*",
              "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg."
    }
  ],
  "id": "CVE-2023-41561",
  "lastModified": "2024-11-21T08:21:18.100",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-08-30T13:15:14.483",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/peris-navince/founded-0-days/blob/main/formSetPPTPServer/1.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/peris-navince/founded-0-days/blob/main/formSetPPTPServer/1.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}