CWE-457

Use of Uninitialized Variable

The code uses a variable that has not been initialized, leading to unpredictable or unintended results.

CVE-2021-41253 (GCVE-0-2021-41253)

Vulnerability from cvelistv5 – Published: 2021-11-08 21:45 – Updated: 2024-08-04 03:08
VLAI
Title
Possible heap buffer overflow when using zycore string functions in formatter hooks
Summary
Zydis is an x86/x86-64 disassembler library. Users of Zydis versions v3.2.0 and older that use the string functions provided in `zycore` in order to append untrusted user data to the formatter buffer within their custom formatter hooks can run into heap buffer overflows. Older versions of Zydis failed to properly initialize the string object within the formatter buffer, forgetting to initialize a few fields, leaving their value to chance. This could then in turn cause zycore functions like `ZyanStringAppend` to make incorrect calculations for the new target size, resulting in heap memory corruption. This does not affect the regular uncustomized Zydis formatter, because Zydis internally doesn't use the string functions in zycore that act upon these fields. However, because the zycore string functions are the intended way to work with the formatter buffer for users of the library that wish to extend the formatter, we still consider this to be a vulnerability in Zydis. This bug is patched starting in version 3.2.1. As a workaround, users may refrain from using zycore string functions in their formatter hooks until updating to a patched version.
CWE
  • CWE-122 - Heap-based Buffer Overflow
  • CWE-457 - Use of Uninitialized Variable
Assigner
Impacted products
Vendor Product Version
zyantific zydis Affected: < 3.2.1
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T03:08:31.619Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://github.com/zyantific/zydis/security/advisories/GHSA-q42v-hv86-3m4g"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/zyantific/zydis/commit/55dd08c210722aed81b38132f5fd4a04ec1943b5"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://huntr.dev/bounties/96b0a482-7041-45b1-9327-c6a4a8f32d3a"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://huntr.dev/bounties/d2536d7d-36ce-4723-928c-98d1ee039784"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "zydis",
          "vendor": "zyantific",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 3.2.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Zydis is an x86/x86-64 disassembler library. Users of Zydis versions v3.2.0 and older that use the string functions provided in `zycore` in order to append untrusted user data to the formatter buffer within their custom formatter hooks can run into heap buffer overflows. Older versions of Zydis failed to properly initialize the string object within the formatter buffer, forgetting to initialize a few fields, leaving their value to chance. This could then in turn cause zycore functions like `ZyanStringAppend` to make incorrect calculations for the new target size, resulting in heap memory corruption. This does not affect the regular uncustomized Zydis formatter, because Zydis internally doesn\u0027t use the string functions in zycore that act upon these fields. However, because the zycore string functions are the intended way to work with the formatter buffer for users of the library that wish to extend the formatter, we still consider this to be a vulnerability in Zydis. This bug is patched starting in version 3.2.1. As a workaround, users may refrain from using zycore string functions in their formatter hooks until updating to a patched version."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122: Heap-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-457",
              "description": "CWE-457: Use of Uninitialized Variable",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-11-08T21:45:11.000Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/zyantific/zydis/security/advisories/GHSA-q42v-hv86-3m4g"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/zyantific/zydis/commit/55dd08c210722aed81b38132f5fd4a04ec1943b5"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://huntr.dev/bounties/96b0a482-7041-45b1-9327-c6a4a8f32d3a"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://huntr.dev/bounties/d2536d7d-36ce-4723-928c-98d1ee039784"
        }
      ],
      "source": {
        "advisory": "GHSA-q42v-hv86-3m4g",
        "discovery": "UNKNOWN"
      },
      "title": "Possible heap buffer overflow when using zycore string functions in formatter hooks",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-advisories@github.com",
          "ID": "CVE-2021-41253",
          "STATE": "PUBLIC",
          "TITLE": "Possible heap buffer overflow when using zycore string functions in formatter hooks"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "zydis",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "\u003c 3.2.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "zyantific"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Zydis is an x86/x86-64 disassembler library. Users of Zydis versions v3.2.0 and older that use the string functions provided in `zycore` in order to append untrusted user data to the formatter buffer within their custom formatter hooks can run into heap buffer overflows. Older versions of Zydis failed to properly initialize the string object within the formatter buffer, forgetting to initialize a few fields, leaving their value to chance. This could then in turn cause zycore functions like `ZyanStringAppend` to make incorrect calculations for the new target size, resulting in heap memory corruption. This does not affect the regular uncustomized Zydis formatter, because Zydis internally doesn\u0027t use the string functions in zycore that act upon these fields. However, because the zycore string functions are the intended way to work with the formatter buffer for users of the library that wish to extend the formatter, we still consider this to be a vulnerability in Zydis. This bug is patched starting in version 3.2.1. As a workaround, users may refrain from using zycore string functions in their formatter hooks until updating to a patched version."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-122: Heap-based Buffer Overflow"
                }
              ]
            },
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-457: Use of Uninitialized Variable"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/zyantific/zydis/security/advisories/GHSA-q42v-hv86-3m4g",
              "refsource": "CONFIRM",
              "url": "https://github.com/zyantific/zydis/security/advisories/GHSA-q42v-hv86-3m4g"
            },
            {
              "name": "https://github.com/zyantific/zydis/commit/55dd08c210722aed81b38132f5fd4a04ec1943b5",
              "refsource": "MISC",
              "url": "https://github.com/zyantific/zydis/commit/55dd08c210722aed81b38132f5fd4a04ec1943b5"
            },
            {
              "name": "https://huntr.dev/bounties/96b0a482-7041-45b1-9327-c6a4a8f32d3a",
              "refsource": "MISC",
              "url": "https://huntr.dev/bounties/96b0a482-7041-45b1-9327-c6a4a8f32d3a"
            },
            {
              "name": "https://huntr.dev/bounties/d2536d7d-36ce-4723-928c-98d1ee039784",
              "refsource": "MISC",
              "url": "https://huntr.dev/bounties/d2536d7d-36ce-4723-928c-98d1ee039784"
            }
          ]
        },
        "source": {
          "advisory": "GHSA-q42v-hv86-3m4g",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2021-41253",
    "datePublished": "2021-11-08T21:45:11.000Z",
    "dateReserved": "2021-09-15T00:00:00.000Z",
    "dateUpdated": "2024-08-04T03:08:31.619Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-44003 (GCVE-0-2021-44003)

Vulnerability from cvelistv5 – Published: 2021-12-14 12:06 – Updated: 2024-08-04 04:10
VLAI
Summary
A vulnerability has been identified in JT2Go (All versions < V13.2.0.5), Teamcenter Visualization (All versions < V13.2.0.5). The Tiff_Loader.dll is vulnerable to use of uninitialized memory while parsing user supplied TIFF files. This could allow an attacker to cause a denial-of-service condition.
Severity
No CVSS data available.
CWE
  • CWE-457 - Use of Uninitialized Variable
Assigner
References
Impacted products
Vendor Product Version
Siemens JT2Go Affected: All versions < V13.2.0.5
Create a notification for this product.
Siemens Teamcenter Visualization Affected: All versions < V13.2.0.5
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:10:17.126Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-595101.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JT2Go",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.2.0.5"
            }
          ]
        },
        {
          "product": "Teamcenter Visualization",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.2.0.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2.0.5), Teamcenter Visualization (All versions \u003c V13.2.0.5). The Tiff_Loader.dll is vulnerable to use of uninitialized memory while parsing user supplied TIFF files. This could allow an attacker to cause a denial-of-service condition."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-457",
              "description": "CWE-457: Use of Uninitialized Variable",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-14T12:06:41.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-595101.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-44003",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "JT2Go",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.2.0.5"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Teamcenter Visualization",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.2.0.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2.0.5), Teamcenter Visualization (All versions \u003c V13.2.0.5). The Tiff_Loader.dll is vulnerable to use of uninitialized memory while parsing user supplied TIFF files. This could allow an attacker to cause a denial-of-service condition."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-457: Use of Uninitialized Variable"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-595101.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-595101.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44003",
    "datePublished": "2021-12-14T12:06:41.000Z",
    "dateReserved": "2021-11-18T00:00:00.000Z",
    "dateUpdated": "2024-08-04T04:10:17.126Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-46566 (GCVE-0-2021-46566)

Vulnerability from cvelistv5 – Published: 2022-02-18 19:44 – Updated: 2024-08-04 05:10
VLAI
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of JT files. The issue results from the lack of proper initialization of memory prior to accessing it. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15027.
CWE
  • CWE-457 - Use of Uninitialized Variable
Assigner
zdi
References
Impacted products
Vendor Product Version
Bentley MicroStation CONNECT Affected: 10.16.0.80
Create a notification for this product.
Credits
xina1i
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T05:10:35.283Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0005"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-153/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "MicroStation CONNECT",
          "vendor": "Bentley",
          "versions": [
            {
              "status": "affected",
              "version": "10.16.0.80"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "xina1i"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of JT files. The issue results from the lack of proper initialization of memory prior to accessing it. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15027."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-457",
              "description": "CWE-457: Use of Uninitialized Variable",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-02-18T19:44:26.000Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0005"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-153/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "zdi-disclosures@trendmicro.com",
          "ID": "CVE-2021-46566",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "MicroStation CONNECT",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "10.16.0.80"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bentley"
              }
            ]
          }
        },
        "credit": "xina1i",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of JT files. The issue results from the lack of proper initialization of memory prior to accessing it. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15027."
            }
          ]
        },
        "impact": {
          "cvss": {
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-457: Use of Uninitialized Variable"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0005",
              "refsource": "MISC",
              "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0005"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-22-153/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-153/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2021-46566",
    "datePublished": "2022-02-18T19:44:26.000Z",
    "dateReserved": "2022-01-26T00:00:00.000Z",
    "dateUpdated": "2024-08-04T05:10:35.283Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-46570 (GCVE-0-2021-46570)

Vulnerability from cvelistv5 – Published: 2022-02-18 19:44 – Updated: 2024-08-04 05:10
VLAI
Summary
This vulnerability allows remote attackers to disclose sensitive information on affected installations of Bentley View 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of JT files. The issue results from the lack of proper initialization of memory prior to accessing it. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-15364.
CWE
  • CWE-457 - Use of Uninitialized Variable
Assigner
zdi
References
Impacted products
Vendor Product Version
Bentley View Affected: 10.16.0.80
Create a notification for this product.
Credits
Mat Powell of Trend Micro Zero Day Initiative
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T05:10:35.352Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0005"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-157/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "View",
          "vendor": "Bentley",
          "versions": [
            {
              "status": "affected",
              "version": "10.16.0.80"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Mat Powell of Trend Micro Zero Day Initiative"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to disclose sensitive information on affected installations of Bentley View 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of JT files. The issue results from the lack of proper initialization of memory prior to accessing it. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-15364."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-457",
              "description": "CWE-457: Use of Uninitialized Variable",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-02-18T19:44:31.000Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0005"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-157/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "zdi-disclosures@trendmicro.com",
          "ID": "CVE-2021-46570",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "View",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "10.16.0.80"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bentley"
              }
            ]
          }
        },
        "credit": "Mat Powell of Trend Micro Zero Day Initiative",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "This vulnerability allows remote attackers to disclose sensitive information on affected installations of Bentley View 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of JT files. The issue results from the lack of proper initialization of memory prior to accessing it. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-15364."
            }
          ]
        },
        "impact": {
          "cvss": {
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-457: Use of Uninitialized Variable"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0005",
              "refsource": "MISC",
              "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0005"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-22-157/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-157/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2021-46570",
    "datePublished": "2022-02-18T19:44:31.000Z",
    "dateReserved": "2022-01-26T00:00:00.000Z",
    "dateUpdated": "2024-08-04T05:10:35.352Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-46617 (GCVE-0-2021-46617)

Vulnerability from cvelistv5 – Published: 2022-02-18 19:45 – Updated: 2024-08-04 05:10
VLAI
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of TIF images. The issue results from the lack of proper initialization of memory prior to accessing it. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15411.
CWE
  • CWE-457 - Use of Uninitialized Variable
Assigner
zdi
References
Impacted products
Vendor Product Version
Bentley MicroStation CONNECT Affected: 10.16.0.80
Create a notification for this product.
Credits
Mat Powell of Trend Micro Zero Day Initiative
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T05:10:35.333Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-204/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0015"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "MicroStation CONNECT",
          "vendor": "Bentley",
          "versions": [
            {
              "status": "affected",
              "version": "10.16.0.80"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Mat Powell of Trend Micro Zero Day Initiative"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of TIF images. The issue results from the lack of proper initialization of memory prior to accessing it. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15411."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-457",
              "description": "CWE-457: Use of Uninitialized Variable",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-02-18T19:45:42.000Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-204/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0015"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "zdi-disclosures@trendmicro.com",
          "ID": "CVE-2021-46617",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "MicroStation CONNECT",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "10.16.0.80"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bentley"
              }
            ]
          }
        },
        "credit": "Mat Powell of Trend Micro Zero Day Initiative",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of TIF images. The issue results from the lack of proper initialization of memory prior to accessing it. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15411."
            }
          ]
        },
        "impact": {
          "cvss": {
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-457: Use of Uninitialized Variable"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-22-204/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-204/"
            },
            {
              "name": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0015",
              "refsource": "MISC",
              "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0015"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2021-46617",
    "datePublished": "2022-02-18T19:45:42.000Z",
    "dateReserved": "2022-01-26T00:00:00.000Z",
    "dateUpdated": "2024-08-04T05:10:35.333Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-46631 (GCVE-0-2021-46631)

Vulnerability from cvelistv5 – Published: 2022-02-18 19:46 – Updated: 2024-08-04 05:10
VLAI
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley View 10.15.0.75. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of TIF images. The issue results from the lack of proper initialization of memory prior to accessing it. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15461.
CWE
  • CWE-457 - Use of Uninitialized Variable
Assigner
zdi
References
Impacted products
Vendor Product Version
Bentley View Affected: 10.15.0.75
Create a notification for this product.
Credits
Mat Powell of Trend Micro Zero Day Initiative
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T05:10:35.417Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0015"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-218/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "View",
          "vendor": "Bentley",
          "versions": [
            {
              "status": "affected",
              "version": "10.15.0.75"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Mat Powell of Trend Micro Zero Day Initiative"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley View 10.15.0.75. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of TIF images. The issue results from the lack of proper initialization of memory prior to accessing it. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15461."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-457",
              "description": "CWE-457: Use of Uninitialized Variable",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-02-18T19:46:03.000Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0015"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-218/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "zdi-disclosures@trendmicro.com",
          "ID": "CVE-2021-46631",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "View",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "10.15.0.75"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bentley"
              }
            ]
          }
        },
        "credit": "Mat Powell of Trend Micro Zero Day Initiative",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley View 10.15.0.75. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of TIF images. The issue results from the lack of proper initialization of memory prior to accessing it. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15461."
            }
          ]
        },
        "impact": {
          "cvss": {
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-457: Use of Uninitialized Variable"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0015",
              "refsource": "MISC",
              "url": "https://www.bentley.com/en/common-vulnerability-exposure/BE-2021-0015"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-22-218/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-218/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2021-46631",
    "datePublished": "2022-02-18T19:46:03.000Z",
    "dateReserved": "2022-01-26T00:00:00.000Z",
    "dateUpdated": "2024-08-04T05:10:35.417Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-21217 (GCVE-0-2022-21217)

Vulnerability from cvelistv5 – Published: 2022-01-28 19:10 – Updated: 2025-04-15 19:21
VLAI
Summary
An out-of-bounds write vulnerability exists in the device TestEmail functionality of reolink RLC-410W v3.0.0.136_20121102. A specially-crafted network request can lead to an out-of-bounds write. An attacker can send an HTTP request to trigger this vulnerability.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-457 - Use of Uninitialized Variable
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T02:31:59.875Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1445"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-21217",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-15T18:14:43.994678Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-15T19:21:09.020Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An out-of-bounds write vulnerability exists in the device TestEmail functionality of reolink RLC-410W v3.0.0.136_20121102. A specially-crafted network request can lead to an out-of-bounds write. An attacker can send an HTTP request to trigger this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-457",
              "description": "CWE-457: Use of Uninitialized Variable",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-01-28T19:10:09.000Z",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1445"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "talos-cna@cisco.com",
          "ID": "CVE-2022-21217",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An out-of-bounds write vulnerability exists in the device TestEmail functionality of reolink RLC-410W v3.0.0.136_20121102. A specially-crafted network request can lead to an out-of-bounds write. An attacker can send an HTTP request to trigger this vulnerability."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 9.1,
            "baseSeverity": "Critical",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-457: Use of Uninitialized Variable"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1445",
              "refsource": "MISC",
              "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1445"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2022-21217",
    "datePublished": "2022-01-28T19:10:09.000Z",
    "dateReserved": "2022-01-11T00:00:00.000Z",
    "dateUpdated": "2025-04-15T19:21:09.020Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2308 (GCVE-0-2022-2308)

Vulnerability from cvelistv5 – Published: 2022-09-01 20:01 – Updated: 2024-08-03 00:32
VLAI
Summary
A flaw was found in vDPA with VDUSE backend. There are currently no checks in VDUSE kernel driver to ensure the size of the device config space is in line with the features advertised by the VDUSE userspace application. In case of a mismatch, Virtio drivers config read helpers do not initialize the memory indirectly passed to vduse_vdpa_get_config() returning uninitialized memory from the stack. This could cause undefined behavior or data leaks in Virtio drivers.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Linux kernel Affected: uknown
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:32:09.598Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://bugzilla.redhat.com/show_bug.cgi?id=2103900"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Linux kernel",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "uknown"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw was found in vDPA with VDUSE backend. There are currently no checks in VDUSE kernel driver to ensure the size of the device config space is in line with the features advertised by the VDUSE userspace application. In case of a mismatch, Virtio drivers config read helpers do not initialize the memory indirectly passed to vduse_vdpa_get_config() returning uninitialized memory from the stack. This could cause undefined behavior or data leaks in Virtio drivers."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-457",
              "description": "CWE-457",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-01T20:01:28.000Z",
        "orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
        "shortName": "redhat"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://bugzilla.redhat.com/show_bug.cgi?id=2103900"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secalert@redhat.com",
          "ID": "CVE-2022-2308",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Linux kernel",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "uknown"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A flaw was found in vDPA with VDUSE backend. There are currently no checks in VDUSE kernel driver to ensure the size of the device config space is in line with the features advertised by the VDUSE userspace application. In case of a mismatch, Virtio drivers config read helpers do not initialize the memory indirectly passed to vduse_vdpa_get_config() returning uninitialized memory from the stack. This could cause undefined behavior or data leaks in Virtio drivers."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-457"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://bugzilla.redhat.com/show_bug.cgi?id=2103900",
              "refsource": "MISC",
              "url": "https://bugzilla.redhat.com/show_bug.cgi?id=2103900"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
    "assignerShortName": "redhat",
    "cveId": "CVE-2022-2308",
    "datePublished": "2022-09-01T20:01:28.000Z",
    "dateReserved": "2022-07-05T00:00:00.000Z",
    "dateUpdated": "2024-08-03T00:32:09.598Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25737 (GCVE-0-2022-25737)

Vulnerability from cvelistv5 – Published: 2023-04-04 04:46 – Updated: 2024-08-03 04:49
VLAI
Title
Use of Uninitialized Variable in MODEM
Summary
Information disclosure in modem due to missing NULL check while reading packets received from local network
CWE
  • CWE-457 - Use of Uninitialized Variable
Assigner
Impacted products
Vendor Product Version
Qualcomm, Inc. Snapdragon Affected: 9205 LTE Modem
Affected: 9206 LTE Modem
Affected: 9207 LTE Modem
Affected: MDM8207
Affected: QCA4004
Affected: QTS110
Affected: Snapdragon 1100 Wearable Platform
Affected: Snapdragon 1200 Wearable Platform
Affected: Snapdragon Wear 1300 Platform
Affected: Snapdragon X5 LTE Modem
Affected: WCD9306
Affected: WCD9330
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:49:43.201Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.qualcomm.com/company/product-security/bulletins/april-2023-bulletin"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Snapdragon Industrial IOT"
          ],
          "product": "Snapdragon",
          "vendor": "Qualcomm, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "9205 LTE Modem"
            },
            {
              "status": "affected",
              "version": "9206 LTE Modem"
            },
            {
              "status": "affected",
              "version": "9207 LTE Modem"
            },
            {
              "status": "affected",
              "version": "MDM8207"
            },
            {
              "status": "affected",
              "version": "QCA4004"
            },
            {
              "status": "affected",
              "version": "QTS110"
            },
            {
              "status": "affected",
              "version": "Snapdragon 1100 Wearable Platform"
            },
            {
              "status": "affected",
              "version": "Snapdragon 1200 Wearable Platform"
            },
            {
              "status": "affected",
              "version": "Snapdragon Wear 1300 Platform"
            },
            {
              "status": "affected",
              "version": "Snapdragon X5 LTE Modem"
            },
            {
              "status": "affected",
              "version": "WCD9306"
            },
            {
              "status": "affected",
              "version": "WCD9330"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Information disclosure in modem due to missing NULL check  while reading packets received from local network"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-457",
              "description": "CWE-457 Use of Uninitialized Variable",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-12T16:28:22.075Z",
        "orgId": "2cfc7d3e-20d3-47ac-8db7-1b7285aff15f",
        "shortName": "qualcomm"
      },
      "references": [
        {
          "url": "https://www.qualcomm.com/company/product-security/bulletins/april-2023-bulletin"
        }
      ],
      "title": "Use of Uninitialized Variable in MODEM"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2cfc7d3e-20d3-47ac-8db7-1b7285aff15f",
    "assignerShortName": "qualcomm",
    "cveId": "CVE-2022-25737",
    "datePublished": "2023-04-04T04:46:16.687Z",
    "dateReserved": "2022-02-22T11:38:09.312Z",
    "dateUpdated": "2024-08-03T04:49:43.201Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-28317 (GCVE-0-2022-28317)

Vulnerability from cvelistv5 – Published: 2023-03-29 00:00 – Updated: 2025-02-18 16:32
VLAI
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.02.34. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of IFC files. The issue results from the lack of proper initialization of memory prior to accessing it. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-16369.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-457 - Use of Uninitialized Variable
Assigner
zdi
Impacted products
Vendor Product Version
Bentley MicroStation CONNECT Affected: 10.16.02.34
Create a notification for this product.
Credits
Anonymous
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:48:37.970Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.bentley.com/en/common-vulnerability-exposure/be-2022-0006"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-604/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-28317",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-18T16:16:26.445506Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-18T16:32:58.090Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "MicroStation CONNECT",
          "vendor": "Bentley",
          "versions": [
            {
              "status": "affected",
              "version": "10.16.02.34"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Anonymous"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.02.34. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of IFC files. The issue results from the lack of proper initialization of memory prior to accessing it. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-16369."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-457",
              "description": "CWE-457: Use of Uninitialized Variable",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-29T00:00:00.000Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "url": "https://www.bentley.com/en/common-vulnerability-exposure/be-2022-0006"
        },
        {
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-604/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2022-28317",
    "datePublished": "2023-03-29T00:00:00.000Z",
    "dateReserved": "2022-03-31T00:00:00.000Z",
    "dateUpdated": "2025-02-18T16:32:58.090Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation ID: MIT-57

Phase: Implementation

Strategy: Attack Surface Reduction

Description:

  • Ensure that critical variables are initialized before first use [REF-1485].
Mitigation

Phase: Build and Compilation

Strategy: Compilation or Build Hardening

Description:

  • Most compilers will complain about the use of uninitialized variables if warnings are turned on.
Mitigation

Phases: Implementation, Operation

Description:

  • When using a language that does not require explicit declaration of variables, run or compile the software in a mode that reports undeclared or unknown variables. This may indicate the presence of a typographic error in the variable's name.
Mitigation

Phase: Requirements

Strategy: Language Selection

Description:

  • Choose a language that is not susceptible to these issues.
Mitigation

Phase: Architecture and Design

Description:

  • Mitigating technologies such as safe string libraries and container abstractions could be introduced.

No CAPEC attack patterns related to this CWE.

Back to CWE stats page