Common Weakness Enumeration
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Back to CWE stats page
CWE-121
Stack-based Buffer Overflow
A stack-based buffer overflow condition is a condition where the buffer being overwritten is allocated on the stack (i.e., is a local variable or, rarely, a parameter to a function).
CVE-2026-11413 (GCVE-0-2026-11413)
Vulnerability from cvelistv5 – Published: 2026-06-06 12:45 – Updated: 2026-06-09 15:45
VLAI
Title
JingDong JD Cloud Box AX6600 jdcweb_rpc set_macfilter stack-based overflow
Summary
A security vulnerability has been detected in JingDong JD Cloud Box AX6600 4.5.3.r4546. The impacted element is the function set_macfilter of the file /sbin/jdcweb_rpc. The manipulation leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/368970 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/368970/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-11413 | third-party-advisory |
| https://vuldb.com/submit/820025 | third-party-advisory |
| http://cdn2.v50to.cc/JDcloud-AX6600_overflow.zip | exploit |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| JingDong | JD Cloud Box AX6600 |
Affected:
4.5.3.r4546
cpe:2.3:a:jingdong:jd_cloud_box_ax6600:*:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-11413",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-09T15:44:54.649603Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-09T15:45:14.931Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://vuldb.com/submit/820025"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:a:jingdong:jd_cloud_box_ax6600:*:*:*:*:*:*:*:*"
],
"product": "JD Cloud Box AX6600",
"vendor": "JingDong",
"versions": [
{
"status": "affected",
"version": "4.5.3.r4546"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "CookedMelon (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability has been detected in JingDong JD Cloud Box AX6600 4.5.3.r4546. The impacted element is the function set_macfilter of the file /sbin/jdcweb_rpc. The manipulation leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-06T12:45:11.552Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-368970 | JingDong JD Cloud Box AX6600 jdcweb_rpc set_macfilter stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/368970"
},
{
"name": "VDB-368970 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/368970/cti"
},
{
"name": "CVE-2026-11413 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-11413"
},
{
"name": "Submit #820025 | JD Cloud AX6600 JDCOS-4.5.3.r4546 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/820025"
},
{
"tags": [
"exploit"
],
"url": "http://cdn2.v50to.cc/JDcloud-AX6600_overflow.zip"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-06-05T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-06-05T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-06-05T20:45:50.000Z",
"value": "VulDB entry last update"
}
],
"title": "JingDong JD Cloud Box AX6600 jdcweb_rpc set_macfilter stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-11413",
"datePublished": "2026-06-06T12:45:11.552Z",
"dateReserved": "2026-06-05T18:40:46.769Z",
"dateUpdated": "2026-06-09T15:45:14.931Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-11498 (GCVE-0-2026-11498)
Vulnerability from cvelistv5 – Published: 2026-06-08 06:45 – Updated: 2026-06-08 16:22
VLAI
Title
Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow
Summary
A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/369118 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/369118/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-11498 | third-party-advisory |
| https://vuldb.com/submit/834887 | third-party-advisory |
| https://github.com/ssaaaa1234/tenda-hg10-voip-oth… | broken-link |
| https://www.tenda.com.cn/ | product |
Impacted products
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-11498",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-08T12:47:31.920390Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T16:22:24.244Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
],
"modules": [
"Web Management Interface"
],
"product": "HG7HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
},
{
"cpes": [
"cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
],
"modules": [
"Web Management Interface"
],
"product": "HG10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "moist (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T06:45:21.289Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-369118 | Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/369118"
},
{
"name": "VDB-369118 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/369118/cti"
},
{
"name": "CVE-2026-11498 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-11498"
},
{
"name": "Submit #834887 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/834887"
},
{
"tags": [
"broken-link"
],
"url": "https://github.com/ssaaaa1234/tenda-hg10-voip-other-set-stack-overflow"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-06-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-06-07T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-06-07T15:27:15.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-11498",
"datePublished": "2026-06-08T06:45:21.289Z",
"dateReserved": "2026-06-07T13:22:12.336Z",
"dateUpdated": "2026-06-08T16:22:24.244Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-11499 (GCVE-0-2026-11499)
Vulnerability from cvelistv5 – Published: 2026-06-08 07:00 – Updated: 2026-06-08 12:55
VLAI
Title
Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow
Summary
A vulnerability was determined in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote.
Severity
9.8 (Critical)
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/369119 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/369119/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-11499 | third-party-advisory |
| https://vuldb.com/submit/834888 | third-party-advisory |
| https://github.com/ssaaaa1234/Tenda-HG10-formDOMA… | broken-link |
| https://www.tenda.com.cn/ | product |
Impacted products
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-11499",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-08T12:55:19.613788Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T12:55:29.374Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
],
"product": "HG7HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
},
{
"cpes": [
"cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
],
"product": "HG10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "moist (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 10,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T07:00:23.672Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-369119 | Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/369119"
},
{
"name": "VDB-369119 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/369119/cti"
},
{
"name": "CVE-2026-11499 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-11499"
},
{
"name": "Submit #834888 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/834888"
},
{
"tags": [
"broken-link"
],
"url": "https://github.com/ssaaaa1234/Tenda-HG10-formDOMAINBLK-stack-overflow-2"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-06-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-06-07T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-06-07T15:28:41.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-11499",
"datePublished": "2026-06-08T07:00:23.672Z",
"dateReserved": "2026-06-07T13:23:38.138Z",
"dateUpdated": "2026-06-08T12:55:29.374Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-11503 (GCVE-0-2026-11503)
Vulnerability from cvelistv5 – Published: 2026-06-08 09:45 – Updated: 2026-06-08 16:22
VLAI
Title
Tenda CX12L Wi-Fi Configuration Endpoint fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow
Summary
A security vulnerability has been detected in Tenda CX12L 16.03.53.12. The affected element is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set of the component Wi-Fi Configuration Endpoint. Such manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/369123 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/369123/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-11503 | third-party-advisory |
| https://vuldb.com/submit/835648 | third-party-advisory |
| https://github.com/cve-a/moist/issues/1 | exploitissue-tracking |
| https://www.tenda.com.cn/ | product |
Impacted products
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-11503",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-08T12:46:27.133276Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T16:22:19.524Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:cx12l_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"Wi-Fi Configuration Endpoint"
],
"product": "CX12L",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "16.03.53.12"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "moist (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability has been detected in Tenda CX12L 16.03.53.12. The affected element is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set of the component Wi-Fi Configuration Endpoint. Such manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T09:45:12.620Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-369123 | Tenda CX12L Wi-Fi Configuration Endpoint fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/369123"
},
{
"name": "VDB-369123 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/369123/cti"
},
{
"name": "CVE-2026-11503 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-11503"
},
{
"name": "Submit #835648 | Tenda CX12L V16.03.53.12 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/835648"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/cve-a/moist/issues/1"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-06-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-06-07T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-06-07T16:06:22.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda CX12L Wi-Fi Configuration Endpoint fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-11503",
"datePublished": "2026-06-08T09:45:12.620Z",
"dateReserved": "2026-06-07T14:01:15.075Z",
"dateUpdated": "2026-06-08T16:22:19.524Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-11504 (GCVE-0-2026-11504)
Vulnerability from cvelistv5 – Published: 2026-06-08 10:00 – Updated: 2026-06-08 12:57
VLAI
Title
Tenda CX12L Wi-Fi Schedule Configuration Endpoint openSchedWifi setSchedWifi stack-based overflow
Summary
A vulnerability was detected in Tenda CX12L 16.03.53.12. The impacted element is the function setSchedWifi of the file /goform/openSchedWifi of the component Wi-Fi Schedule Configuration Endpoint. Performing a manipulation of the argument schedStartTime/schedEndTime results in stack-based buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/369124 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/369124/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-11504 | third-party-advisory |
| https://vuldb.com/submit/835649 | third-party-advisory |
| https://github.com/cve-a/moist/issues/2 | exploitissue-tracking |
| https://www.tenda.com.cn/ | product |
Impacted products
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-11504",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-08T12:57:07.691843Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T12:57:17.537Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:cx12l_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"Wi-Fi Schedule Configuration Endpoint"
],
"product": "CX12L",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "16.03.53.12"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "moist (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was detected in Tenda CX12L 16.03.53.12. The impacted element is the function setSchedWifi of the file /goform/openSchedWifi of the component Wi-Fi Schedule Configuration Endpoint. Performing a manipulation of the argument schedStartTime/schedEndTime results in stack-based buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T10:00:13.594Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-369124 | Tenda CX12L Wi-Fi Schedule Configuration Endpoint openSchedWifi setSchedWifi stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/369124"
},
{
"name": "VDB-369124 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/369124/cti"
},
{
"name": "CVE-2026-11504 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-11504"
},
{
"name": "Submit #835649 | Tenda CX12L V16.03.53.12 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/835649"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/cve-a/moist/issues/2"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-06-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-06-07T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-06-07T16:06:25.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda CX12L Wi-Fi Schedule Configuration Endpoint openSchedWifi setSchedWifi stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-11504",
"datePublished": "2026-06-08T10:00:13.594Z",
"dateReserved": "2026-06-07T14:01:17.439Z",
"dateUpdated": "2026-06-08T12:57:17.537Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-11522 (GCVE-0-2026-11522)
Vulnerability from cvelistv5 – Published: 2026-06-08 14:30 – Updated: 2026-06-08 15:52
VLAI
Title
Tenda W20E setPortMirror formSetPortMirror stack-based overflow
Summary
A vulnerability was detected in Tenda W20E 15.11.0.6. This vulnerability affects the function formSetPortMirror of the file /goform/setPortMirror. Performing a manipulation of the argument portMirrorMirroredPorts results in stack-based buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/369142 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/369142/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-11522 | third-party-advisory |
| https://vuldb.com/submit/836469 | third-party-advisory |
| https://github.com/Robots10/IoT_vlu/blob/main/rep… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-11522",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-08T15:52:11.957984Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T15:52:25.265Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*"
],
"product": "W20E",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.11.0.6"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "hacker128 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was detected in Tenda W20E 15.11.0.6. This vulnerability affects the function formSetPortMirror of the file /goform/setPortMirror. Performing a manipulation of the argument portMirrorMirroredPorts results in stack-based buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T14:30:11.465Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-369142 | Tenda W20E setPortMirror formSetPortMirror stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/369142"
},
{
"name": "VDB-369142 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/369142/cti"
},
{
"name": "CVE-2026-11522 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-11522"
},
{
"name": "Submit #836469 | Tenda W20E Enterprise Router V15.11.0.6 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/836469"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Robots10/IoT_vlu/blob/main/reports/Tenda/formSetPortMirror/portMirrorMirroredPorts.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-06-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-06-07T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-06-07T18:11:47.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda W20E setPortMirror formSetPortMirror stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-11522",
"datePublished": "2026-06-08T14:30:11.465Z",
"dateReserved": "2026-06-07T16:06:39.937Z",
"dateUpdated": "2026-06-08T15:52:25.265Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-11523 (GCVE-0-2026-11523)
Vulnerability from cvelistv5 – Published: 2026-06-08 14:45 – Updated: 2026-06-08 16:36
VLAI
Title
Tenda W20E Web Management PortalAuth formPortalAuth stack-based overflow
Summary
A flaw has been found in Tenda W20E 15.11.0.6. This issue affects the function formPortalAuth of the file /goform/PortalAuth of the component Web Management Interface. Executing a manipulation of the argument gotoUrl can lead to stack-based buffer overflow. The attack can be launched remotely. The exploit has been published and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/369143 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/369143/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-11523 | third-party-advisory |
| https://vuldb.com/submit/836471 | third-party-advisory |
| https://github.com/Robots10/IoT_vlu/blob/main/rep… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-11523",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-08T16:35:00.338505Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T16:36:03.017Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/Robots10/IoT_vlu/blob/main/reports/Tenda/formPortalAuth/formPortalAuth.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"Web Management Interface"
],
"product": "W20E",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.11.0.6"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "hacker128 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw has been found in Tenda W20E 15.11.0.6. This issue affects the function formPortalAuth of the file /goform/PortalAuth of the component Web Management Interface. Executing a manipulation of the argument gotoUrl can lead to stack-based buffer overflow. The attack can be launched remotely. The exploit has been published and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T14:45:09.883Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-369143 | Tenda W20E Web Management PortalAuth formPortalAuth stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/369143"
},
{
"name": "VDB-369143 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/369143/cti"
},
{
"name": "CVE-2026-11523 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-11523"
},
{
"name": "Submit #836471 | Tenda W20E Enterprise Router V15.11.0.6 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/836471"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Robots10/IoT_vlu/blob/main/reports/Tenda/formPortalAuth/formPortalAuth.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-06-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-06-07T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-06-07T18:11:50.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda W20E Web Management PortalAuth formPortalAuth stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-11523",
"datePublished": "2026-06-08T14:45:09.883Z",
"dateReserved": "2026-06-07T16:06:42.495Z",
"dateUpdated": "2026-06-08T16:36:03.017Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-11524 (GCVE-0-2026-11524)
Vulnerability from cvelistv5 – Published: 2026-06-08 15:00 – Updated: 2026-06-09 15:26
VLAI
Title
Tenda W20E Web Management modifyWifiFilterRules stack-based overflow
Summary
A vulnerability has been found in Tenda W20E 15.11.0.6. Impacted is the function modifyWifiFilterRules of the file /goform/modifyWifiFilterRules of the component Web Management Interface. The manipulation of the argument wifiFilterListRemark leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/369144 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/369144/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-11524 | third-party-advisory |
| https://vuldb.com/submit/836478 | third-party-advisory |
| https://github.com/Robots10/IoT_vlu/blob/main/rep… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-11524",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-09T15:25:13.664719Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-09T15:26:03.032Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:w20e_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"Web Management Interface"
],
"product": "W20E",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.11.0.6"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "hacker128 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Tenda W20E 15.11.0.6. Impacted is the function modifyWifiFilterRules of the file /goform/modifyWifiFilterRules of the component Web Management Interface. The manipulation of the argument wifiFilterListRemark leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T15:00:16.713Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-369144 | Tenda W20E Web Management modifyWifiFilterRules stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/369144"
},
{
"name": "VDB-369144 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/369144/cti"
},
{
"name": "CVE-2026-11524 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-11524"
},
{
"name": "Submit #836478 | Tenda Tenda W20E Enterprise Router V15.11.0.6 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/836478"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Robots10/IoT_vlu/blob/main/reports/Tenda/formWifiFilterRulesModify/modifyWifiFilterRules.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-06-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-06-07T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-06-07T18:12:40.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda W20E Web Management modifyWifiFilterRules stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-11524",
"datePublished": "2026-06-08T15:00:16.713Z",
"dateReserved": "2026-06-07T16:07:35.577Z",
"dateUpdated": "2026-06-09T15:26:03.032Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-11528 (GCVE-0-2026-11528)
Vulnerability from cvelistv5 – Published: 2026-06-08 15:15 – Updated: 2026-06-09 14:35
VLAI
Title
Tenda AC18 Web Management getRebootStatus sub_45304 stack-based overflow
Summary
A vulnerability was found in Tenda AC18 15.03.05.05. The affected element is the function sub_45304 of the file /goform/getRebootStatus of the component Web Management Interface. The manipulation of the argument callback results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been made public and could be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/369145 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/369145/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-11528 | third-party-advisory |
| https://vuldb.com/submit/836474 | third-party-advisory |
| https://github.com/Robots10/IoT_vlu/blob/main/rep… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-11528",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-09T14:27:07.795609Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-09T14:35:55.593Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac18_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"Web Management Interface"
],
"product": "AC18",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.05"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "hacker128 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC18 15.03.05.05. The affected element is the function sub_45304 of the file /goform/getRebootStatus of the component Web Management Interface. The manipulation of the argument callback results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been made public and could be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T15:15:12.614Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-369145 | Tenda AC18 Web Management getRebootStatus sub_45304 stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/369145"
},
{
"name": "VDB-369145 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/369145/cti"
},
{
"name": "CVE-2026-11528 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-11528"
},
{
"name": "Submit #836474 | Tenda Tenda AC18 Wireless Router V15.03.05.05 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/836474"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Robots10/IoT_vlu/blob/main/reports/Tenda/getRebootStatus/getRebootStatus.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-06-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-06-07T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-06-07T21:47:18.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC18 Web Management getRebootStatus sub_45304 stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-11528",
"datePublished": "2026-06-08T15:15:12.614Z",
"dateReserved": "2026-06-07T19:42:14.647Z",
"dateUpdated": "2026-06-09T14:35:55.593Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-11553 (GCVE-0-2026-11553)
Vulnerability from cvelistv5 – Published: 2026-06-08 17:15 – Updated: 2026-06-08 18:49
VLAI
Title
Tenda HG7HG9/HG10 formPPPEdit stack-based overflow
Summary
A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
7 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/369163 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/369163/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-11553 | third-party-advisory |
| https://vuldb.com/submit/836778 | third-party-advisory |
| https://github.com/xiezhihua-1127/Tenda-Stack-Ove… | related |
| https://github.com/xiezhihua-1127/Tenda-Stack-Ove… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-11553",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-08T18:49:04.954919Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T18:49:14.135Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
],
"product": "HG7HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
},
{
"cpes": [
"cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
],
"product": "HG10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "zhihua xie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T17:15:11.855Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-369163 | Tenda HG7HG9/HG10 formPPPEdit stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/369163"
},
{
"name": "VDB-369163 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/369163/cti"
},
{
"name": "CVE-2026-11553 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-11553"
},
{
"name": "Submit #836778 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/836778"
},
{
"tags": [
"related"
],
"url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow.git"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow/blob/main/report.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-06-08T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-06-08T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-06-08T07:48:34.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG7HG9/HG10 formPPPEdit stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-11553",
"datePublished": "2026-06-08T17:15:11.855Z",
"dateReserved": "2026-06-08T05:43:31.214Z",
"dateUpdated": "2026-06-08T18:49:14.135Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
Mitigation ID: MIT-10
Phases: Operation, Build and Compilation
Strategy: Environment Hardening
Description:
- Use automatic buffer overflow detection mechanisms that are offered by certain compilers or compiler extensions. Examples include: the Microsoft Visual Studio /GS flag, Fedora/Red Hat FORTIFY_SOURCE GCC flag, StackGuard, and ProPolice, which provide various mechanisms including canary-based detection and range/index checking.
- D3-SFCV (Stack Frame Canary Validation) from D3FEND [REF-1334] discusses canary-based detection in detail.
Mitigation
Phase: Architecture and Design
Description:
- Use an abstraction library to abstract away risky APIs. Not a complete solution.
Mitigation
Phase: Implementation
Description:
- Implement and perform bounds checking on input.
Mitigation
Phase: Implementation
Description:
- Do not use dangerous functions such as gets. Use safer, equivalent functions which check for boundary errors.
Mitigation ID: MIT-11
Phases: Operation, Build and Compilation
Strategy: Environment Hardening
Description:
- Run or compile the software using features or extensions that randomly arrange the positions of a program's executable and libraries in memory. Because this makes the addresses unpredictable, it can prevent an attacker from reliably jumping to exploitable code.
- Examples include Address Space Layout Randomization (ASLR) [REF-58] [REF-60] and Position-Independent Executables (PIE) [REF-64]. Imported modules may be similarly realigned if their default memory addresses conflict with other modules, in a process known as "rebasing" (for Windows) and "prelinking" (for Linux) [REF-1332] using randomly generated addresses. ASLR for libraries cannot be used in conjunction with prelink since it would require relocating the libraries at run-time, defeating the whole purpose of prelinking.
- For more information on these techniques see D3-SAOR (Segment Address Offset Randomization) from D3FEND [REF-1335].
No CAPEC attack patterns related to this CWE.