Common Weakness Enumeration
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Show details on NVD website
Back to CWE stats page
CWE-121
Stack-based Buffer Overflow
A stack-based buffer overflow condition is a condition where the buffer being overwritten is allocated on the stack (i.e., is a local variable or, rarely, a parameter to a function).
CVE-2025-7544 (GCVE-0-2025-7544)
Vulnerability from cvelistv5 – Published: 2025-07-13 21:32 – Updated: 2025-07-15 19:53
VLAI
Title
Tenda AC1206 setMacFilterCfg formSetMacFilterCfg stack-based overflow
Summary
A vulnerability was found in Tenda AC1206 15.03.06.23. It has been rated as critical. This issue affects the function formSetMacFilterCfg of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.316241 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.316241 | signaturepermissions-required |
| https://vuldb.com/?submit.614089 | third-party-advisory |
| https://github.com/panda666-888/vuls/blob/main/te… | related |
| https://github.com/panda666-888/vuls/blob/main/te… | exploit |
| https://www.tenda.com.cn/ | product |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7544",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-14T16:43:46.557917Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-15T19:53:10.386Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/ac1206/formSetMacFilterCfg.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC1206",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.23"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "panda_0x1 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC1206 15.03.06.23. It has been rated as critical. This issue affects the function formSetMacFilterCfg of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda AC1206 15.03.06.23 ausgemacht. Sie wurde als kritisch eingestuft. Es geht hierbei um die Funktion formSetMacFilterCfg der Datei /goform/setMacFilterCfg. Mit der Manipulation des Arguments deviceList mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-13T21:32:07.187Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-316241 | Tenda AC1206 setMacFilterCfg formSetMacFilterCfg stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.316241"
},
{
"name": "VDB-316241 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.316241"
},
{
"name": "Submit #614089 | Tenda AC1206 15.03.06.23 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.614089"
},
{
"tags": [
"related"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/ac1206/formSetMacFilterCfg.md"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/ac1206/formSetMacFilterCfg.md#poc"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-07-12T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-07-12T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-07-12T15:35:54.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC1206 setMacFilterCfg formSetMacFilterCfg stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-7544",
"datePublished": "2025-07-13T21:32:07.187Z",
"dateReserved": "2025-07-12T13:30:51.339Z",
"dateUpdated": "2025-07-15T19:53:10.386Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-7548 (GCVE-0-2025-7548)
Vulnerability from cvelistv5 – Published: 2025-07-13 22:32 – Updated: 2025-07-14 15:56
VLAI
Title
Tenda FH1201 SafeEmailFilter formSafeEmailFilter stack-based overflow
Summary
A vulnerability has been found in Tenda FH1201 1.2.0.14(408) and classified as critical. This vulnerability affects the function formSafeEmailFilter of the file /goform/SafeEmailFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.316246 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.316246 | signaturepermissions-required |
| https://vuldb.com/?submit.614658 | third-party-advisory |
| https://github.com/panda666-888/vuls/blob/main/te… | related |
| https://github.com/panda666-888/vuls/blob/main/te… | exploit |
| https://www.tenda.com.cn/ | product |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7548",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-14T15:56:45.970390Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-14T15:56:48.926Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/formSafeEmailFilter.md#poc"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/formSafeEmailFilter.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FH1201",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "panda_0x1 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Tenda FH1201 1.2.0.14(408) and classified as critical. This vulnerability affects the function formSafeEmailFilter of the file /goform/SafeEmailFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Tenda FH1201 1.2.0.14(408) wurde eine kritische Schwachstelle gefunden. Das betrifft die Funktion formSafeEmailFilter der Datei /goform/SafeEmailFilter. Durch das Manipulieren des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-13T22:32:07.492Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-316246 | Tenda FH1201 SafeEmailFilter formSafeEmailFilter stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.316246"
},
{
"name": "VDB-316246 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.316246"
},
{
"name": "Submit #614658 | Tenda FH1201 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.614658"
},
{
"tags": [
"related"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/formSafeEmailFilter.md"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/formSafeEmailFilter.md#poc"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-07-12T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-07-12T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-07-12T19:11:32.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1201 SafeEmailFilter formSafeEmailFilter stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-7548",
"datePublished": "2025-07-13T22:32:07.492Z",
"dateReserved": "2025-07-12T17:06:22.580Z",
"dateUpdated": "2025-07-14T15:56:48.926Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-7549 (GCVE-0-2025-7549)
Vulnerability from cvelistv5 – Published: 2025-07-13 22:44 – Updated: 2025-07-14 13:55
VLAI
Title
Tenda FH1201 L7Prot frmL7ProtForm stack-based overflow
Summary
A vulnerability was found in Tenda FH1201 1.2.0.14(408) and classified as critical. This issue affects the function frmL7ProtForm of the file /goform/L7Prot. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.316247 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.316247 | signaturepermissions-required |
| https://vuldb.com/?submit.614973 | third-party-advisory |
| https://github.com/panda666-888/vuls/blob/main/te… | related |
| https://github.com/panda666-888/vuls/blob/main/te… | exploit |
| https://www.tenda.com.cn/ | product |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7549",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-14T13:55:01.694988Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-14T13:55:07.574Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/frmL7ProtForm.md#poc"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/frmL7ProtForm.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FH1201",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "panda_0xf1 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda FH1201 1.2.0.14(408) and classified as critical. This issue affects the function frmL7ProtForm of the file /goform/L7Prot. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda FH1201 1.2.0.14(408) gefunden. Dies betrifft die Funktion frmL7ProtForm der Datei /goform/L7Prot. Durch Manipulieren des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-13T22:44:06.676Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-316247 | Tenda FH1201 L7Prot frmL7ProtForm stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.316247"
},
{
"name": "VDB-316247 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.316247"
},
{
"name": "Submit #614973 | Tenda FH1201 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.614973"
},
{
"tags": [
"related"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/frmL7ProtForm.md"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/frmL7ProtForm.md#poc"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-07-12T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-07-12T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-07-12T19:22:12.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1201 L7Prot frmL7ProtForm stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-7549",
"datePublished": "2025-07-13T22:44:06.676Z",
"dateReserved": "2025-07-12T17:16:57.184Z",
"dateUpdated": "2025-07-14T13:55:07.574Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-7550 (GCVE-0-2025-7550)
Vulnerability from cvelistv5 – Published: 2025-07-13 23:02 – Updated: 2025-07-14 13:52
VLAI
Title
Tenda FH1201 GstDhcpSetSer fromGstDhcpSetSer stack-based overflow
Summary
A vulnerability was found in Tenda FH1201 1.2.0.14(408). It has been classified as critical. Affected is the function fromGstDhcpSetSer of the file /goform/GstDhcpSetSer. The manipulation of the argument dips leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.316248 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.316248 | signaturepermissions-required |
| https://vuldb.com/?submit.614974 | third-party-advisory |
| https://github.com/panda666-888/vuls/blob/main/te… | related |
| https://github.com/panda666-888/vuls/blob/main/te… | exploit |
| https://www.tenda.com.cn/ | product |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7550",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-14T13:52:22.327649Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-14T13:52:25.344Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/fromGstDhcpSetSer.md#poc"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/fromGstDhcpSetSer.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FH1201",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "panda_0xf1 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda FH1201 1.2.0.14(408). It has been classified as critical. Affected is the function fromGstDhcpSetSer of the file /goform/GstDhcpSetSer. The manipulation of the argument dips leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda FH1201 1.2.0.14(408) ausgemacht. Dabei betrifft es die Funktion fromGstDhcpSetSer der Datei /goform/GstDhcpSetSer. Durch das Beeinflussen des Arguments dips mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-13T23:02:07.618Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-316248 | Tenda FH1201 GstDhcpSetSer fromGstDhcpSetSer stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.316248"
},
{
"name": "VDB-316248 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.316248"
},
{
"name": "Submit #614974 | Tenda FH1201 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.614974"
},
{
"tags": [
"related"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/fromGstDhcpSetSer.md"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/fromGstDhcpSetSer.md#poc"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-07-12T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-07-12T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-07-12T19:22:13.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1201 GstDhcpSetSer fromGstDhcpSetSer stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-7550",
"datePublished": "2025-07-13T23:02:07.618Z",
"dateReserved": "2025-07-12T17:17:00.643Z",
"dateUpdated": "2025-07-14T13:52:25.344Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-7551 (GCVE-0-2025-7551)
Vulnerability from cvelistv5 – Published: 2025-07-13 23:14 – Updated: 2025-07-14 13:46
VLAI
Title
Tenda FH1201 PPTPDClient fromPptpUserAdd stack-based overflow
Summary
A vulnerability was found in Tenda FH1201 1.2.0.14(408). It has been declared as critical. Affected by this vulnerability is the function fromPptpUserAdd of the file /goform/PPTPDClient. The manipulation of the argument modino/username leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
7 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.316249 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.316249 | signaturepermissions-required |
| https://vuldb.com/?submit.614975 | third-party-advisory |
| https://vuldb.com/?submit.614976 | third-party-advisory |
| https://github.com/panda666-888/vuls/blob/main/te… | related |
| https://github.com/panda666-888/vuls/blob/main/te… | exploit |
| https://www.tenda.com.cn/ | product |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7551",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-14T13:46:03.050924Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-14T13:46:07.393Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/fromPptpUserAdd_modino.md#poc"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/fromPptpUserAdd_modino.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FH1201",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "panda_0xf1 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda FH1201 1.2.0.14(408). It has been declared as critical. Affected by this vulnerability is the function fromPptpUserAdd of the file /goform/PPTPDClient. The manipulation of the argument modino/username leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Tenda FH1201 1.2.0.14(408) wurde eine kritische Schwachstelle ausgemacht. Hierbei betrifft es die Funktion fromPptpUserAdd der Datei /goform/PPTPDClient. Durch Beeinflussen des Arguments modino/username mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-13T23:14:07.247Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-316249 | Tenda FH1201 PPTPDClient fromPptpUserAdd stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.316249"
},
{
"name": "VDB-316249 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.316249"
},
{
"name": "Submit #614975 | Tenda FH1201 V1.2.0.14(408) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.614975"
},
{
"name": "Submit #614976 | Tenda FH1201 V1.2.0.14(408) Buffer Overflow (Duplicate)",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.614976"
},
{
"tags": [
"related"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/fromPptpUserAdd_modino.md"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1201/fromPptpUserAdd_modino.md#poc"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-07-12T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-07-12T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-07-12T19:26:27.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1201 PPTPDClient fromPptpUserAdd stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-7551",
"datePublished": "2025-07-13T23:14:07.247Z",
"dateReserved": "2025-07-12T17:17:03.533Z",
"dateUpdated": "2025-07-14T13:46:07.393Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-7586 (GCVE-0-2025-7586)
Vulnerability from cvelistv5 – Published: 2025-07-14 08:02 – Updated: 2025-07-14 15:22
VLAI
Title
Tenda AC500 setWtpData formSetAPCfg stack-based overflow
Summary
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. Affected by this vulnerability is the function formSetAPCfg of the file /goform/setWtpData. The manipulation of the argument radio_2g_1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.316285 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.316285 | signaturepermissions-required |
| https://vuldb.com/?submit.615169 | third-party-advisory |
| https://github.com/panda666-888/vuls/blob/main/te… | related |
| https://github.com/panda666-888/vuls/blob/main/te… | exploit |
| https://www.tenda.com.cn/ | product |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7586",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-14T15:09:40.026670Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-14T15:22:29.586Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC500",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "2.0.1.9(1307)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "panda_0x1 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. Affected by this vulnerability is the function formSetAPCfg of the file /goform/setWtpData. The manipulation of the argument radio_2g_1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Tenda AC500 2.0.1.9(1307) wurde eine kritische Schwachstelle ausgemacht. Es geht um die Funktion formSetAPCfg der Datei /goform/setWtpData. Mit der Manipulation des Arguments radio_2g_1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-14T08:02:06.975Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-316285 | Tenda AC500 setWtpData formSetAPCfg stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.316285"
},
{
"name": "VDB-316285 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.316285"
},
{
"name": "Submit #615169 | Tenda AC500 V2.0.1.9(1307) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.615169"
},
{
"tags": [
"related"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/ac500/formSetAPCfg.md"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/ac500/formSetAPCfg.md#poc"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-07-13T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-07-13T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-07-13T15:03:11.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC500 setWtpData formSetAPCfg stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-7586",
"datePublished": "2025-07-14T08:02:06.975Z",
"dateReserved": "2025-07-13T12:58:01.563Z",
"dateUpdated": "2025-07-14T15:22:29.586Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-7596 (GCVE-0-2025-7596)
Vulnerability from cvelistv5 – Published: 2025-07-14 10:32 – Updated: 2025-07-14 10:57
VLAI
Title
Tenda FH1205 WifiExtraSet formWifiExtraSet stack-based overflow
Summary
A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been rated as critical. This issue affects the function formWifiExtraSet of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.316295 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.316295 | signaturepermissions-required |
| https://vuldb.com/?submit.615251 | third-party-advisory |
| https://github.com/panda666-888/vuls/blob/main/te… | related |
| https://github.com/panda666-888/vuls/blob/main/te… | exploit |
| https://www.tenda.com.cn/ | product |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7596",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-14T10:47:21.049793Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-14T10:57:15.809Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FH1205",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "2.0.0.7(775)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "panda_0x1 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been rated as critical. This issue affects the function formWifiExtraSet of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda FH1205 2.0.0.7(775) ausgemacht. Sie wurde als kritisch eingestuft. Davon betroffen ist die Funktion formWifiExtraSet der Datei /goform/WifiExtraSet. Dank Manipulation des Arguments wpapsk_crypto mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-14T10:32:07.099Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-316295 | Tenda FH1205 WifiExtraSet formWifiExtraSet stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.316295"
},
{
"name": "VDB-316295 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.316295"
},
{
"name": "Submit #615251 | Tenda FH1205 V2.0.0.7(775) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.615251"
},
{
"tags": [
"related"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1205/formWifiExtraSet.md"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/fh1205/formWifiExtraSet.md#poc"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-07-13T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-07-13T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-07-13T15:14:19.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1205 WifiExtraSet formWifiExtraSet stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-7596",
"datePublished": "2025-07-14T10:32:07.099Z",
"dateReserved": "2025-07-13T13:09:16.337Z",
"dateUpdated": "2025-07-14T10:57:15.809Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-7597 (GCVE-0-2025-7597)
Vulnerability from cvelistv5 – Published: 2025-07-14 10:44 – Updated: 2025-07-14 12:46
VLAI
Title
Tenda AX1803 setMacFilterCfg formSetMacFilterCfg stack-based overflow
Summary
A vulnerability classified as critical has been found in Tenda AX1803 1.0.0.1. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.316296 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.316296 | signaturepermissions-required |
| https://vuldb.com/?submit.615268 | third-party-advisory |
| https://github.com/panda666-888/vuls/blob/main/te… | related |
| https://github.com/panda666-888/vuls/blob/main/te… | exploit |
| https://www.tenda.com.cn/ | product |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7597",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-14T12:46:37.870432Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-14T12:46:49.239Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AX1803",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.1"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "panda_0x1 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical has been found in Tenda AX1803 1.0.0.1. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda AX1803 1.0.0.1 entdeckt. Hiervon betroffen ist die Funktion formSetMacFilterCfg der Datei /goform/setMacFilterCfg. Mit der Manipulation des Arguments deviceList mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-14T10:44:06.851Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-316296 | Tenda AX1803 setMacFilterCfg formSetMacFilterCfg stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.316296"
},
{
"name": "VDB-316296 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.316296"
},
{
"name": "Submit #615268 | Tenda AX1803 V1.0.0.1 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.615268"
},
{
"tags": [
"related"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/ax1803/formSetMacFilterCfg.md"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/ax1803/formSetMacFilterCfg.md#poc"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-07-13T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-07-13T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-07-13T15:18:26.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AX1803 setMacFilterCfg formSetMacFilterCfg stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-7597",
"datePublished": "2025-07-14T10:44:06.851Z",
"dateReserved": "2025-07-13T13:13:17.958Z",
"dateUpdated": "2025-07-14T12:46:49.239Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-7598 (GCVE-0-2025-7598)
Vulnerability from cvelistv5 – Published: 2025-07-14 11:02 – Updated: 2025-07-14 12:43
VLAI
Title
Tenda AX1803 setWifiFilterCfg formSetWifiMacFilterCfg stack-based overflow
Summary
A vulnerability classified as critical was found in Tenda AX1803 1.0.0.1. Affected by this vulnerability is the function formSetWifiMacFilterCfg of the file /goform/setWifiFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.316297 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.316297 | signaturepermissions-required |
| https://vuldb.com/?submit.615269 | third-party-advisory |
| https://github.com/panda666-888/vuls/blob/main/te… | related |
| https://github.com/panda666-888/vuls/blob/main/te… | exploit |
| https://www.tenda.com.cn/ | product |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7598",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-14T12:42:00.366931Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-14T12:43:01.808Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AX1803",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.1"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "panda_0x1 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical was found in Tenda AX1803 1.0.0.1. Affected by this vulnerability is the function formSetWifiMacFilterCfg of the file /goform/setWifiFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Tenda AX1803 1.0.0.1 wurde eine kritische Schwachstelle entdeckt. Betroffen ist die Funktion formSetWifiMacFilterCfg der Datei /goform/setWifiFilterCfg. Durch die Manipulation des Arguments deviceList mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-14T11:02:07.422Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-316297 | Tenda AX1803 setWifiFilterCfg formSetWifiMacFilterCfg stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.316297"
},
{
"name": "VDB-316297 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.316297"
},
{
"name": "Submit #615269 | Tenda AX1803 V1.0.0.1 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.615269"
},
{
"tags": [
"related"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/ax1803/formSetWifiMacFilterCfg.md"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/panda666-888/vuls/blob/main/tenda/ax1803/formSetWifiMacFilterCfg.md#poc"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-07-13T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-07-13T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-07-13T15:18:28.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AX1803 setWifiFilterCfg formSetWifiMacFilterCfg stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-7598",
"datePublished": "2025-07-14T11:02:07.422Z",
"dateReserved": "2025-07-13T13:13:20.225Z",
"dateUpdated": "2025-07-14T12:43:01.808Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-7602 (GCVE-0-2025-7602)
Vulnerability from cvelistv5 – Published: 2025-07-14 12:02 – Updated: 2025-07-14 13:35
VLAI
Title
D-Link DI-8100 HTTP Request arp_sys.asp stack-based overflow
Summary
A vulnerability was found in D-Link DI-8100 16.07.26A1 and classified as critical. This issue affects some unknown processing of the file /arp_sys.asp of the component HTTP Request Handler. The manipulation leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.316301 | vdb-entry |
| https://vuldb.com/?ctiid.316301 | signaturepermissions-required |
| https://vuldb.com/?submit.615302 | third-party-advisory |
| https://github.com/XiDP0/MyCVE/blob/main/CVE/D-Li… | exploit |
| https://www.dlink.com/ | product |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7602",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-14T13:35:37.232591Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-14T13:35:40.003Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/XiDP0/MyCVE/blob/main/CVE/D-Link%20DI_8100-16.07.26A1/arp_sys_asp/arp_sys_asp.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"HTTP Request Handler"
],
"product": "DI-8100",
"vendor": "D-Link",
"versions": [
{
"status": "affected",
"version": "16.07.26A1"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "XiDP (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in D-Link DI-8100 16.07.26A1 and classified as critical. This issue affects some unknown processing of the file /arp_sys.asp of the component HTTP Request Handler. The manipulation leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in D-Link DI-8100 16.07.26A1 gefunden. Es geht hierbei um eine nicht n\u00e4her spezifizierte Funktion der Datei /arp_sys.asp der Komponente HTTP Request Handler. Durch das Manipulieren mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 8.3,
"vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-14T12:02:06.530Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-316301 | D-Link DI-8100 HTTP Request arp_sys.asp stack-based overflow",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/?id.316301"
},
{
"name": "VDB-316301 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.316301"
},
{
"name": "Submit #615302 | D-Link DI-8100 16.07.26A1 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.615302"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/XiDP0/MyCVE/blob/main/CVE/D-Link%20DI_8100-16.07.26A1/arp_sys_asp/arp_sys_asp.md"
},
{
"tags": [
"product"
],
"url": "https://www.dlink.com/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-07-13T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-07-13T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-07-13T16:41:51.000Z",
"value": "VulDB entry last update"
}
],
"title": "D-Link DI-8100 HTTP Request arp_sys.asp stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-7602",
"datePublished": "2025-07-14T12:02:06.530Z",
"dateReserved": "2025-07-13T14:36:44.566Z",
"dateUpdated": "2025-07-14T13:35:40.003Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation ID: MIT-10
Phases: Operation, Build and Compilation
Strategy: Environment Hardening
Description:
- Use automatic buffer overflow detection mechanisms that are offered by certain compilers or compiler extensions. Examples include: the Microsoft Visual Studio /GS flag, Fedora/Red Hat FORTIFY_SOURCE GCC flag, StackGuard, and ProPolice, which provide various mechanisms including canary-based detection and range/index checking.
- D3-SFCV (Stack Frame Canary Validation) from D3FEND [REF-1334] discusses canary-based detection in detail.
Mitigation
Phase: Architecture and Design
Description:
- Use an abstraction library to abstract away risky APIs. Not a complete solution.
Mitigation
Phase: Implementation
Description:
- Implement and perform bounds checking on input.
Mitigation
Phase: Implementation
Description:
- Do not use dangerous functions such as gets. Use safer, equivalent functions which check for boundary errors.
Mitigation ID: MIT-11
Phases: Operation, Build and Compilation
Strategy: Environment Hardening
Description:
- Run or compile the software using features or extensions that randomly arrange the positions of a program's executable and libraries in memory. Because this makes the addresses unpredictable, it can prevent an attacker from reliably jumping to exploitable code.
- Examples include Address Space Layout Randomization (ASLR) [REF-58] [REF-60] and Position-Independent Executables (PIE) [REF-64]. Imported modules may be similarly realigned if their default memory addresses conflict with other modules, in a process known as "rebasing" (for Windows) and "prelinking" (for Linux) [REF-1332] using randomly generated addresses. ASLR for libraries cannot be used in conjunction with prelink since it would require relocating the libraries at run-time, defeating the whole purpose of prelinking.
- For more information on these techniques see D3-SAOR (Segment Address Offset Randomization) from D3FEND [REF-1335].
No CAPEC attack patterns related to this CWE.