CWE-1191

On-Chip Debug and Test Interface With Improper Access Control

The chip does not implement or does not correctly perform access control to check whether users are authorized to access internal registers and test modes through the physical debug/test interface.

CVE-2025-12114 (GCVE-0-2025-12114)
Vulnerability from cvelistv5
Published
2025-10-23 15:29
Modified
2025-10-23 15:39
CWE
  • CWE-1191 - On-Chip Debug and Test Interface With Improper Access Control
Summary
Enabled serial console could potentially leak information that might help attacker to find vulnerabilities.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-12114",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-23T15:39:28.696245Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-23T15:39:46.781Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "BLU-IC2",
          "vendor": "Azure Access Technology",
          "versions": [
            {
              "lessThanOrEqual": "1.19.5",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "BLU-IC4",
          "vendor": "Azure Access Technology",
          "versions": [
            {
              "lessThanOrEqual": "1.19.5",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Kevin Schaller"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Benjamin Lafois"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Alexi Bitsios"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Sebastian Toscano"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Dominik Schneider"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eEnabled\u0026nbsp;\u003c/span\u003eserial console could potentially leak information that might help attacker to find vulnerabilities.\u003cp\u003eThis issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5.\u003c/p\u003e"
            }
          ],
          "value": "Enabled\u00a0serial console could potentially leak information that might help attacker to find vulnerabilities.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-1",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-1: Accessing Functionality Not Properly Constrained by ACLs"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 5.2,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:L/VI:L/VA:L/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "LOW",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1191",
              "description": "CWE-1191: On-Chip Debug and Test Interface With Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-23T15:29:13.361Z",
        "orgId": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
        "shortName": "azure-access"
      },
      "references": [
        {
          "url": "https://azure-access.com/security-advisories"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Serial Console Enabled",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
    "assignerShortName": "azure-access",
    "cveId": "CVE-2025-12114",
    "datePublished": "2025-10-23T15:29:13.361Z",
    "dateReserved": "2025-10-23T15:23:36.517Z",
    "dateUpdated": "2025-10-23T15:39:46.781Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-15083 (GCVE-0-2025-15083)
Vulnerability from cvelistv5
Published
2025-12-25 17:32
Modified
2025-12-25 17:32
CWE
  • CWE-1191 - On-Chip Debug and Test Interface With Improper Access Control
Summary
A vulnerability was determined in TOZED ZLT M30s up to 1.47. The affected element is an unknown function of the component UART Interface. Executing manipulation can lead to on-chip debug and test interface with improper access control. The physical device can be targeted for the attack. Attacks of this nature are highly complex. The exploitability is described as difficult. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
References
Impacted products
Vendor Product Version
TOZED ZLT M30s Version: 1.0
Version: 1.1
Version: 1.2
Version: 1.3
Version: 1.4
Version: 1.5
Version: 1.6
Version: 1.7
Version: 1.8
Version: 1.9
Version: 1.10
Version: 1.11
Version: 1.12
Version: 1.13
Version: 1.14
Version: 1.15
Version: 1.16
Version: 1.17
Version: 1.18
Version: 1.19
Version: 1.20
Version: 1.21
Version: 1.22
Version: 1.23
Version: 1.24
Version: 1.25
Version: 1.26
Version: 1.27
Version: 1.28
Version: 1.29
Version: 1.30
Version: 1.31
Version: 1.32
Version: 1.33
Version: 1.34
Version: 1.35
Version: 1.36
Version: 1.37
Version: 1.38
Version: 1.39
Version: 1.40
Version: 1.41
Version: 1.42
Version: 1.43
Version: 1.44
Version: 1.45
Version: 1.46
Version: 1.47
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "cna": {
      "affected": [
        {
          "modules": [
            "UART Interface"
          ],
          "product": "ZLT M30s",
          "vendor": "TOZED",
          "versions": [
            {
              "status": "affected",
              "version": "1.0"
            },
            {
              "status": "affected",
              "version": "1.1"
            },
            {
              "status": "affected",
              "version": "1.2"
            },
            {
              "status": "affected",
              "version": "1.3"
            },
            {
              "status": "affected",
              "version": "1.4"
            },
            {
              "status": "affected",
              "version": "1.5"
            },
            {
              "status": "affected",
              "version": "1.6"
            },
            {
              "status": "affected",
              "version": "1.7"
            },
            {
              "status": "affected",
              "version": "1.8"
            },
            {
              "status": "affected",
              "version": "1.9"
            },
            {
              "status": "affected",
              "version": "1.10"
            },
            {
              "status": "affected",
              "version": "1.11"
            },
            {
              "status": "affected",
              "version": "1.12"
            },
            {
              "status": "affected",
              "version": "1.13"
            },
            {
              "status": "affected",
              "version": "1.14"
            },
            {
              "status": "affected",
              "version": "1.15"
            },
            {
              "status": "affected",
              "version": "1.16"
            },
            {
              "status": "affected",
              "version": "1.17"
            },
            {
              "status": "affected",
              "version": "1.18"
            },
            {
              "status": "affected",
              "version": "1.19"
            },
            {
              "status": "affected",
              "version": "1.20"
            },
            {
              "status": "affected",
              "version": "1.21"
            },
            {
              "status": "affected",
              "version": "1.22"
            },
            {
              "status": "affected",
              "version": "1.23"
            },
            {
              "status": "affected",
              "version": "1.24"
            },
            {
              "status": "affected",
              "version": "1.25"
            },
            {
              "status": "affected",
              "version": "1.26"
            },
            {
              "status": "affected",
              "version": "1.27"
            },
            {
              "status": "affected",
              "version": "1.28"
            },
            {
              "status": "affected",
              "version": "1.29"
            },
            {
              "status": "affected",
              "version": "1.30"
            },
            {
              "status": "affected",
              "version": "1.31"
            },
            {
              "status": "affected",
              "version": "1.32"
            },
            {
              "status": "affected",
              "version": "1.33"
            },
            {
              "status": "affected",
              "version": "1.34"
            },
            {
              "status": "affected",
              "version": "1.35"
            },
            {
              "status": "affected",
              "version": "1.36"
            },
            {
              "status": "affected",
              "version": "1.37"
            },
            {
              "status": "affected",
              "version": "1.38"
            },
            {
              "status": "affected",
              "version": "1.39"
            },
            {
              "status": "affected",
              "version": "1.40"
            },
            {
              "status": "affected",
              "version": "1.41"
            },
            {
              "status": "affected",
              "version": "1.42"
            },
            {
              "status": "affected",
              "version": "1.43"
            },
            {
              "status": "affected",
              "version": "1.44"
            },
            {
              "status": "affected",
              "version": "1.45"
            },
            {
              "status": "affected",
              "version": "1.46"
            },
            {
              "status": "affected",
              "version": "1.47"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "S33K3R (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was determined in TOZED ZLT M30s up to 1.47. The affected element is an unknown function of the component UART Interface. Executing manipulation can lead to on-chip debug and test interface with improper access control. The physical device can be targeted for the attack. Attacks of this nature are highly complex. The exploitability is described as difficult. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 1,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:4.0/AV:P/AC:H/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 2,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 2,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.0/AV:P/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 1.2,
            "vectorString": "AV:L/AC:H/Au:N/C:P/I:N/A:N/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1191",
              "description": "On-Chip Debug and Test Interface With Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-25T17:32:06.260Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-338411 | TOZED ZLT M30s UART on-chip debug and test interface with improper access control",
          "tags": [
            "vdb-entry"
          ],
          "url": "https://vuldb.com/?id.338411"
        },
        {
          "name": "VDB-338411 | CTI Indicators (IOB, IOC)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.338411"
        },
        {
          "name": "Submit #707974 | TOZED ZLT M30s 1.47 Improper Access Control in Debug Interface",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.707974"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://hacklab.eu.org/blogs/zlt_m30s_debug_interface"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-12-25T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-12-25T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-12-25T10:42:28.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TOZED ZLT M30s UART on-chip debug and test interface with improper access control"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-15083",
    "datePublished": "2025-12-25T17:32:06.260Z",
    "dateReserved": "2025-12-25T09:36:38.360Z",
    "dateUpdated": "2025-12-25T17:32:06.260Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-26408 (GCVE-0-2025-26408)
Vulnerability from cvelistv5
Published
2025-02-11 09:14
Modified
2025-11-03 21:12
CWE
  • CWE-1191 - On-Chip Debug and Test Interface With Improper Access Control
Summary
The JTAG interface of Wattsense Bridge devices can be accessed with physical access to the PCB. After connecting to the interface, full access to the device is possible. This enables an attacker to extract information, modify and debug the device's firmware. All known versions are affected.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "PHYSICAL",
              "availabilityImpact": "NONE",
              "baseScore": 6.1,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-26408",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-11T14:40:43.535274Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-22T14:41:30.878Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-03T21:12:50.335Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://seclists.org/fulldisclosure/2025/Feb/9"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Wattsense Bridge",
          "vendor": "Wattsense",
          "versions": [
            {
              "status": "affected",
              "version": "*"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Constantin Schieber-Kn\u00f6bl | SEC Consult Vulnerability Lab"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Stefan Schweighofer | SEC Consult Vulnerability Lab"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Steffen Robertz | SEC Consult Vulnerability Lab"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The JTAG interface of Wattsense Bridge devices can be accessed with physical access to the PCB. After connecting to the interface, full access to the device is possible. This enables an attacker to extract information, modify and debug the device\u0027s firmware. All known versions are affected.\u003cbr\u003e\u003cbr\u003e"
            }
          ],
          "value": "The JTAG interface of Wattsense Bridge devices can be accessed with physical access to the PCB. After connecting to the interface, full access to the device is possible. This enables an attacker to extract information, modify and debug the device\u0027s firmware. All known versions are affected."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-702",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-702 Exploiting Incorrect Chaining or Granularity of Hardware Debug Components"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1191",
              "description": "CWE-1191 On-Chip Debug and Test Interface With Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-11T09:14:28.700Z",
        "orgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
        "shortName": "SEC-VLab"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://r.sec-consult.com/wattsense"
        },
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://support.wattsense.com/hc/en-150/articles/13366066529437-Release-Notes"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe device is meant to be installed at a restricted access physical location according to the vendor and exploitation requires\u0026nbsp;\u003c/span\u003emore attacker knowledge and higher physical access. The issue will be put in the backlog of the Wattsense team."
            }
          ],
          "value": "The device is meant to be installed at a restricted access physical location according to the vendor and exploitation requires\u00a0more attacker knowledge and higher physical access. The issue will be put in the backlog of the Wattsense team."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Unprotected JTAG Interface",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
    "assignerShortName": "SEC-VLab",
    "cveId": "CVE-2025-26408",
    "datePublished": "2025-02-11T09:14:28.700Z",
    "dateReserved": "2025-02-10T07:48:38.352Z",
    "dateUpdated": "2025-11-03T21:12:50.335Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-26409 (GCVE-0-2025-26409)
Vulnerability from cvelistv5
Published
2025-02-11 09:15
Modified
2025-11-03 21:12
CWE
  • CWE-1299 - Missing Protection Mechanism for Alternate Hardware Interface
  • CWE-1191 - On-Chip Debug and Test Interface With Improper Access Control
Summary
A serial interface can be accessed with physical access to the PCB of Wattsense Bridge devices. After connecting to the interface, access to the bootloader is possible, as well as a Linux login prompt. The bootloader access can be used to gain a root shell on the device. This issue is fixed in recent firmware versions BSP >= 6.4.1.
Impacted products
Vendor Product Version
Wattsense Wattsense Bridge Version: 0   < 6.4.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "PHYSICAL",
              "availabilityImpact": "HIGH",
              "baseScore": 6.8,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-26409",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-11T14:38:08.176508Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-1299",
                "description": "CWE-1299 Missing Protection Mechanism for Alternate Hardware Interface",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-17T16:40:45.172Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-03T21:12:51.730Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://seclists.org/fulldisclosure/2025/Feb/9"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Wattsense Bridge",
          "vendor": "Wattsense",
          "versions": [
            {
              "lessThan": "6.4.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Constantin Schieber-Kn\u00f6bl | SEC Consult Vulnerability Lab"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Stefan Schweighofer | SEC Consult Vulnerability Lab"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Steffen Robertz | SEC Consult Vulnerability Lab"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A serial interface can be accessed with physical access to the PCB of Wattsense Bridge devices. After connecting to the interface, access to the bootloader is possible, as well as a Linux login prompt. The bootloader access can be used to gain a root shell on the device. This issue is fixed in\u0026nbsp;recent firmware versions BSP \u0026gt;= 6.4.1."
            }
          ],
          "value": "A serial interface can be accessed with physical access to the PCB of Wattsense Bridge devices. After connecting to the interface, access to the bootloader is possible, as well as a Linux login prompt. The bootloader access can be used to gain a root shell on the device. This issue is fixed in\u00a0recent firmware versions BSP \u003e= 6.4.1."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-180",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-180 Exploiting Incorrectly Configured Access Control Security Levels"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1299",
              "description": "CWE-1299 Missing Protection Mechanism for Alternate Hardware Interface",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-1191",
              "description": "CWE-1191 On-Chip Debug and Test Interface With Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-11T09:15:30.131Z",
        "orgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
        "shortName": "SEC-VLab"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://r.sec-consult.com/wattsense"
        },
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://support.wattsense.com/hc/en-150/articles/13366066529437-Release-Notes"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "This issue is fixed in recent firmware versions BSP \u0026gt;= 6.4.1."
            }
          ],
          "value": "This issue is fixed in recent firmware versions BSP \u003e= 6.4.1."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Access to Bootloader and Shell Over Serial Interface",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
    "assignerShortName": "SEC-VLab",
    "cveId": "CVE-2025-26409",
    "datePublished": "2025-02-11T09:15:30.131Z",
    "dateReserved": "2025-02-10T07:48:38.352Z",
    "dateUpdated": "2025-11-03T21:12:51.730Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-36755 (GCVE-0-2025-36755)
Vulnerability from cvelistv5
Published
2025-12-12 14:58
Modified
2025-12-13 08:16
CWE
  • CWE-1244 - Internal Asset Exposed to Unsafe Debug Access Level or State
  • CWE-1191 - On-Chip Debug and Test Interface With Improper Access Control
Summary
The CleverDisplay BlueOne hardware player is designed with its USB interfaces physically enclosed and inaccessible under normal operating conditions. Researchers demonstrated that, after cicumventing the device’s protective enclosure, it was possible to connect a USB keyboard and press ESC during boot to access the BIOS setup interface. BIOS settings could be viewed but not modified. This behavior slightly increases the attack surface by exposing internal system information (CWE-1244) once the enclosure is removed, but does not allow integrity or availability compromise under standard or tested configurations.
References
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-36755",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-12T18:50:02.532239Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-12T18:50:19.575Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "modules": [
            "Enclosure / USB keyboard interface / BIOS \u0026 GRUB boot process"
          ],
          "product": "BlueOne (CleverDisplay Hardware Player)",
          "vendor": "CleverDisplay B.V.",
          "versions": [
            {
              "status": "affected",
              "version": "12.11.1",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "*",
              "status": "unaffected",
              "version": "12.12.1",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Alwin Warringa, Tom Dantuma, Ruben Meeuwissen, and Ramon Dunker."
        },
        {
          "lang": "en",
          "type": "analyst",
          "value": "Dennis Kussendrager (DIVD)"
        },
        {
          "lang": "en",
          "type": "analyst",
          "value": "Victor Pasman  (DIVD)"
        }
      ],
      "datePublic": "2025-08-09T16:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The CleverDisplay BlueOne hardware player is designed with its USB interfaces physically enclosed and inaccessible under normal operating conditions. Researchers demonstrated that, after cicumventing the device\u2019s protective enclosure, it was possible to connect a USB keyboard and press \u003cstrong\u003eESC\u003c/strong\u003e during boot to access the BIOS setup interface. BIOS settings could be viewed but not modified. This behavior slightly increases the attack surface by exposing internal system information (CWE-1244) once the enclosure is removed, but does not allow integrity or availability compromise under standard or tested configurations."
            }
          ],
          "value": "The CleverDisplay BlueOne hardware player is designed with its USB interfaces physically enclosed and inaccessible under normal operating conditions. Researchers demonstrated that, after cicumventing the device\u2019s protective enclosure, it was possible to connect a USB keyboard and press ESC during boot to access the BIOS setup interface. BIOS settings could be viewed but not modified. This behavior slightly increases the attack surface by exposing internal system information (CWE-1244) once the enclosure is removed, but does not allow integrity or availability compromise under standard or tested configurations."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Proof-of-concept demonstrated by researchers at WHY2025; exploitation confirmed limited to BIOS access without ability to modify settings.\u003cbr\u003e\u003cbr\u003e"
            }
          ],
          "value": "Proof-of-concept demonstrated by researchers at WHY2025; exploitation confirmed limited to BIOS access without ability to modify settings."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-522",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-522 Malicious Hardware Component Replacement"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NO",
            "Recovery": "NOT_DEFINED",
            "Safety": "NEGLIGIBLE",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "PHYSICAL",
            "baseScore": 2.4,
            "baseSeverity": "LOW",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "GREEN",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "DIFFUSE",
            "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/S:N/AU:N/V:D/RE:L/U:Green",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "LOW"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1244",
              "description": "CWE-1244: Internal Asset Exposed to Unsafe Debug Access Level or State",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-1191",
              "description": "CWE-1191: On-Chip Debug and Test Interface With Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-13T08:16:14.495Z",
        "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "shortName": "DIVD"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://csirt.divd.nl/CVE-2025-5743/"
        },
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://csirt.divd.nl/DIVD-2025-00043"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "BlueOne firmware version 12.2.1 introduces default BIOS password protection and Secure Boot enablement, preventing unauthorized BIOS access."
            }
          ],
          "value": "BlueOne firmware version 12.2.1 introduces default BIOS password protection and Secure Boot enablement, preventing unauthorized BIOS access."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "CleverDisplay BlueOne unauthorized BIOS access through physical USB keyboard",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
    "assignerShortName": "DIVD",
    "cveId": "CVE-2025-36755",
    "datePublished": "2025-12-12T14:58:22.970Z",
    "dateReserved": "2025-04-15T21:54:36.815Z",
    "dateUpdated": "2025-12-13T08:16:14.495Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-47819 (GCVE-0-2025-47819)
Vulnerability from cvelistv5
Published
2025-06-27 00:00
Modified
2025-09-02 16:24
CWE
  • CWE-1191 - On-Chip Debug and Test Interface With Improper Access Control
Summary
Flock Safety Gunshot Detection devices before 1.3 have an on-chip debug interface with improper access control.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-47819",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-30T18:51:49.384704Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-30T18:55:02.941Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Gunshot Detection devices",
          "vendor": "Flock Safety",
          "versions": [
            {
              "lessThan": "1.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Flock Safety Gunshot Detection devices before 1.3 have an on-chip debug interface with improper access control."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1191",
              "description": "CWE-1191 On-Chip Debug and Test Interface With Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-02T16:24:24.424Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.flocksafety.com/articles/gunshot-detection-and-license-plate-reader-security-alert"
        },
        {
          "url": "https://gainsec.com/2025/06/19/bird-hunting-season-security-research-on-flock-safety-anti-crime-systems/"
        },
        {
          "url": "https://gainsec.com/wp-content/uploads/2025/06/flock-safety-researcher-summary.pdf"
        },
        {
          "url": "https://gainsec.com/2025/06/19/plucked-and-rooted-device-1-debug-shell-on-flock-safetys-raven-gunshot-detection-system/"
        }
      ],
      "x_generator": {
        "engine": "enrichogram 0.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-47819",
    "datePublished": "2025-06-27T00:00:00.000Z",
    "dateReserved": "2025-05-10T00:00:00.000Z",
    "dateUpdated": "2025-09-02T16:24:24.424Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-47822 (GCVE-0-2025-47822)
Vulnerability from cvelistv5
Published
2025-06-27 00:00
Modified
2025-09-02 16:12
CWE
  • CWE-1191 - On-Chip Debug and Test Interface With Improper Access Control
Summary
Flock Safety LPR (License Plate Reader) devices with firmware through 2.2 have an on-chip debug interface with improper access control.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-47822",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-30T18:51:12.457246Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-30T18:51:21.036Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "License Plate Reader",
          "vendor": "Flock Safety",
          "versions": [
            {
              "lessThanOrEqual": "2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Flock Safety LPR (License Plate Reader) devices with firmware through 2.2 have an on-chip debug interface with improper access control."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1191",
              "description": "CWE-1191 On-Chip Debug and Test Interface With Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-02T16:12:06.946Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.flocksafety.com/articles/gunshot-detection-and-license-plate-reader-security-alert"
        },
        {
          "url": "https://gainsec.com/2025/06/19/bird-hunting-season-security-research-on-flock-safety-anti-crime-systems/"
        },
        {
          "url": "https://gainsec.com/2025/06/19/grounded-flight-device-2-root-shell-on-flock-safetys-falcon-sparrow-automated-license-plate-reader/"
        },
        {
          "url": "https://gainsec.com/wp-content/uploads/2025/06/flock-safety-researcher-summary.pdf"
        }
      ],
      "x_generator": {
        "engine": "enrichogram 0.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-47822",
    "datePublished": "2025-06-27T00:00:00.000Z",
    "dateReserved": "2025-05-10T00:00:00.000Z",
    "dateUpdated": "2025-09-02T16:12:06.946Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-7213 (GCVE-0-2025-7213)
Vulnerability from cvelistv5
Published
2025-07-09 03:02
Modified
2025-07-09 17:28
CWE
  • CWE-1191 - On-Chip Debug and Test Interface With Improper Access Control
Summary
A vulnerability classified as critical has been found in FNKvision FNK-GU2 up to 40.1.7. Affected is an unknown function of the component UART Interface. The manipulation leads to on-chip debug and test interface with improper access control. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used.
Impacted products
Vendor Product Version
FNKvision FNK-GU2 Version: 40.1.0
Version: 40.1.1
Version: 40.1.2
Version: 40.1.3
Version: 40.1.4
Version: 40.1.5
Version: 40.1.6
Version: 40.1.7
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-7213",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-09T17:27:32.987870Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-09T17:28:36.758Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "UART Interface"
          ],
          "product": "FNK-GU2",
          "vendor": "FNKvision",
          "versions": [
            {
              "status": "affected",
              "version": "40.1.0"
            },
            {
              "status": "affected",
              "version": "40.1.1"
            },
            {
              "status": "affected",
              "version": "40.1.2"
            },
            {
              "status": "affected",
              "version": "40.1.3"
            },
            {
              "status": "affected",
              "version": "40.1.4"
            },
            {
              "status": "affected",
              "version": "40.1.5"
            },
            {
              "status": "affected",
              "version": "40.1.6"
            },
            {
              "status": "affected",
              "version": "40.1.7"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "0xHasta (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical has been found in FNKvision FNK-GU2 up to 40.1.7. Affected is an unknown function of the component UART Interface. The manipulation leads to on-chip debug and test interface with improper access control. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in FNKvision FNK-GU2 bis 40.1.7 entdeckt. Es geht dabei um eine nicht klar definierte Funktion der Komponente UART Interface. Dank Manipulation mit unbekannten Daten kann eine on-chip debug and test interface with improper access control-Schwachstelle ausgenutzt werden. Ein Angriff setzt physischen Zugriff auf dem Zielobjekt voraus. Die Komplexit\u00e4t eines Angriffs ist eher hoch. Sie gilt als schwierig auszunutzen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:P/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.2,
            "vectorString": "AV:L/AC:H/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1191",
              "description": "On-Chip Debug and Test Interface With Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-09T03:02:05.807Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-315162 | FNKvision FNK-GU2 UART Interface on-chip debug and test interface with improper access control",
          "tags": [
            "vdb-entry"
          ],
          "url": "https://vuldb.com/?id.315162"
        },
        {
          "name": "VDB-315162 | CTI Indicators (IOB, IOC)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.315162"
        },
        {
          "name": "Submit #608025 | FNKvision FNK-GU2 Wireless IP Camera Firmware version 40.1.7 and prior On-Chip Debug and Test Interface With Improper Access Control (C",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.608025"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://medium.com/@pundhapat/sqli-in-the-cloud-root-on-the-board-a-beginners-journey-into-iot-hacking-06efb2539a21"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-07-07T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-07-07T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-07-07T15:24:26.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "FNKvision FNK-GU2 UART Interface on-chip debug and test interface with improper access control"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-7213",
    "datePublished": "2025-07-09T03:02:05.807Z",
    "dateReserved": "2025-07-07T13:19:13.819Z",
    "dateUpdated": "2025-07-09T17:28:36.758Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-9709 (GCVE-0-2025-9709)
Vulnerability from cvelistv5
Published
2025-09-05 17:16
Modified
2025-09-05 18:07
CWE
  • CWE-1191 - On-Chip Debug and Test Interface With Improper Access Control
  • CWE-1319 - Improper Protection against Electromagnetic Fault Injection (EM-FI)
  • Runtime Hardware Protection Bypass
Summary
On-Chip Debug and Test Interface With Improper Access Control and Improper Protection against Electromagnetic Fault Injection (EM-FI) in Nordic Semiconductor nRF52810 allow attacker to perform EM Fault Injection and bypass APPROTECT at runtime, requiring the least amount of modification to the hardware system possible.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-9709",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-05T18:07:39.209816Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-05T18:07:49.930Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "collectionURL": "https://www.nordicsemi.com/Products/nRF52810",
          "defaultStatus": "unaffected",
          "product": "nRF52810",
          "vendor": "Nordic Semiconductor",
          "versions": [
            {
              "status": "affected",
              "version": "0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Milena Mangiola"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "On-Chip Debug and Test Interface With Improper Access Control and Improper Protection against Electromagnetic Fault Injection (EM-FI) in Nordic Semiconductor nRF52810 allow attacker to perform EM Fault Injection and bypass APPROTECT at runtime, requiring the least amount of modification to the hardware system possible."
            }
          ],
          "value": "On-Chip Debug and Test Interface With Improper Access Control and Improper Protection against Electromagnetic Fault Injection (EM-FI) in Nordic Semiconductor nRF52810 allow attacker to perform EM Fault Injection and bypass APPROTECT at runtime, requiring the least amount of modification to the hardware system possible."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-624",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-624: Hardware Fault Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "PRESENT",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "PHYSICAL",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/S:P",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1191",
              "description": "CWE-1191: On-Chip Debug and Test Interface With Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-1319",
              "description": "CWE-1319: Improper Protection against Electromagnetic Fault Injection (EM-FI)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "description": "Runtime Hardware Protection Bypass",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-05T17:16:16.345Z",
        "orgId": "1c6b5737-9389-4011-8117-89fa251edfb2",
        "shortName": "Toreon"
      },
      "references": [
        {
          "url": "https://raelize.com/upload/research/2022/No_Hat_2022_-_Glitching_devices_for_code_execution_v1.1.pdf"
        },
        {
          "url": "https://raelize.com/upload/research/2025/Dartmouth_202505_False-Injections-Tales-of-Physics-Misconceptions-and-Weird-Machines_v1.1.pdf"
        },
        {
          "url": "https://nvd.nist.gov/vuln/detail/CVE-2020-27211"
        },
        {
          "url": "https://www.toreon.com/cve-2025-9709-major-vulnerability-in-common-chip/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "NRF52810 Runtime EM Fault Injection APPROTECT Bypass",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1c6b5737-9389-4011-8117-89fa251edfb2",
    "assignerShortName": "Toreon",
    "cveId": "CVE-2025-9709",
    "datePublished": "2025-09-05T17:16:16.345Z",
    "dateReserved": "2025-08-29T16:27:34.512Z",
    "dateUpdated": "2025-09-05T18:07:49.930Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}


Mitigation

Phase: Architecture and Design

Strategy: Separation of Privilege

Description:

  • If feasible, the manufacturer should disable the JTAG interface or implement authentication and authorization for the JTAG interface. If authentication logic is added, it should be resistant to timing attacks. Security-sensitive data stored in registers, such as keys, etc. should be cleared when entering debug mode.
CAPEC-1: Accessing Functionality Not Properly Constrained by ACLs

In applications, particularly web applications, access to functionality is mitigated by an authorization framework. This framework maps Access Control Lists (ACLs) to elements of the application's functionality; particularly URL's for web apps. In the case that the administrator failed to specify an ACL for a particular element, an attacker may be able to access it with impunity. An attacker with the ability to access functionality not properly constrained by ACLs can obtain sensitive information and possibly compromise the entire application. Such an attacker can access resources that must be available only to users at a higher privilege level, can access management sections of the application, or can run queries for data that they otherwise not supposed to.

CAPEC-180: Exploiting Incorrectly Configured Access Control Security Levels

An attacker exploits a weakness in the configuration of access controls and is able to bypass the intended protection that these measures guard against and thereby obtain unauthorized access to the system or network. Sensitive functionality should always be protected with access controls. However configuring all but the most trivial access control systems can be very complicated and there are many opportunities for mistakes. If an attacker can learn of incorrectly configured access security settings, they may be able to exploit this in an attack.

Back to CWE stats page