Unrestricted Upload of File with Dangerous Type

Abstraction: Base · Status: Draft

The product allows the upload or transfer of dangerous file types that are automatically processed within its environment.

5966 vulnerabilities reference this CWE, most recent first.

CVE-2017-16772 (GCVE-0-2017-16772)

Vulnerability from cvelistv5 – Published: 2018-03-22 14:00 – Updated: 2024-09-17 04:23
VLAI
Summary
Improper input validation vulnerability in SYNOPHOTO_Flickr_MultiUpload in Synology Photo Station before 6.8.3-3463 and before 6.3-2971 allows remote authenticated users to execute arbitrary codes via the prog_id parameter.
Severity
No CVSS data available.
CWE
  • CWE-434 - Unrestricted Upload of File with Dangerous Type (CWE-434)
Assigner
References
Impacted products
Vendor Product Version
Synology Photo Station Affected: before 6.8.3-3463
Affected: before 6.3-2971
Create a notification for this product.
Date Public
2018-03-22 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T20:35:20.953Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.synology.com/en-global/support/security/Synology_SA_18_02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Photo Station",
          "vendor": "Synology",
          "versions": [
            {
              "status": "affected",
              "version": "before 6.8.3-3463"
            },
            {
              "status": "affected",
              "version": "before 6.3-2971"
            }
          ]
        }
      ],
      "datePublic": "2018-03-22T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper input validation vulnerability in SYNOPHOTO_Flickr_MultiUpload in Synology Photo Station before 6.8.3-3463 and before 6.3-2971 allows remote authenticated users to execute arbitrary codes via the prog_id parameter."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-434",
              "description": "Unrestricted Upload of File with Dangerous Type (CWE-434)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-22T13:57:01.000Z",
        "orgId": "db201096-a0cc-46c7-9a55-61d9e221bf01",
        "shortName": "synology"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.synology.com/en-global/support/security/Synology_SA_18_02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@synology.com",
          "DATE_PUBLIC": "2018-03-22T00:00:00",
          "ID": "CVE-2017-16772",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Photo Station",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "before 6.8.3-3463"
                          },
                          {
                            "version_value": "before 6.3-2971"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Synology"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Improper input validation vulnerability in SYNOPHOTO_Flickr_MultiUpload in Synology Photo Station before 6.8.3-3463 and before 6.3-2971 allows remote authenticated users to execute arbitrary codes via the prog_id parameter."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Unrestricted Upload of File with Dangerous Type (CWE-434)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.synology.com/en-global/support/security/Synology_SA_18_02",
              "refsource": "CONFIRM",
              "url": "https://www.synology.com/en-global/support/security/Synology_SA_18_02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "db201096-a0cc-46c7-9a55-61d9e221bf01",
    "assignerShortName": "synology",
    "cveId": "CVE-2017-16772",
    "datePublished": "2018-03-22T14:00:00.000Z",
    "dateReserved": "2017-11-10T00:00:00.000Z",
    "dateUpdated": "2024-09-17T04:23:49.491Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-16736 (GCVE-0-2017-16736)

Vulnerability from cvelistv5 – Published: 2018-01-12 02:00 – Updated: 2024-08-05 20:35
VLAI
Summary
An Unrestricted Upload Of File With Dangerous Type issue was discovered in Advantech WebAccess versions prior to 8.3. WebAccess allows a remote attacker to upload arbitrary files.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Advantech WebAccess Affected: Advantech WebAccess
Date Public
2018-01-11 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T20:35:20.670Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-02A"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Advantech WebAccess",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Advantech WebAccess"
            }
          ]
        }
      ],
      "datePublic": "2018-01-11T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Unrestricted Upload Of File With Dangerous Type issue was discovered in Advantech WebAccess versions prior to 8.3. WebAccess allows a remote attacker to upload arbitrary files."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-434",
              "description": "CWE-434",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-01-12T01:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-02A"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-16736",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Advantech WebAccess",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Advantech WebAccess"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Unrestricted Upload Of File With Dangerous Type issue was discovered in Advantech WebAccess versions prior to 8.3. WebAccess allows a remote attacker to upload arbitrary files."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-434"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-02A",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-02A"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-16736",
    "datePublished": "2018-01-12T02:00:00.000Z",
    "dateReserved": "2017-11-09T00:00:00.000Z",
    "dateUpdated": "2024-08-05T20:35:20.670Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-16594 (GCVE-0-2017-16594)

Vulnerability from cvelistv5 – Published: 2018-01-23 01:00 – Updated: 2024-08-05 20:27
VLAI
Summary
This vulnerability allows remote attackers to create arbitrary files on vulnerable installations of NetGain Systems Enterprise Manager 7.2.730 build 1034. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the org.apache.jsp.u.jsp.db.save_005fimage_jsp servlet, which listens on TCP port 8081 by default. When parsing the id parameter, the process does not properly validate user-supplied data, which can allow for the upload of files. An attacker can leverage this vulnerability to execute code under the context of Administrator. Was ZDI-CAN-5117.
Severity
No CVSS data available.
CWE
  • CWE-434 - Unrestricted Upload of File with Dangerous Type
Assigner
zdi
References
Impacted products
Date Public
2017-12-13 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T20:27:04.404Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://zerodayinitiative.com/advisories/ZDI-17-959"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "NetGain Systems Enterprise Manager",
          "vendor": "NetGain Systems",
          "versions": [
            {
              "status": "affected",
              "version": "7.2.730 build 1034"
            }
          ]
        }
      ],
      "datePublic": "2017-12-13T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to create arbitrary files on vulnerable installations of NetGain Systems Enterprise Manager 7.2.730 build 1034. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the org.apache.jsp.u.jsp.db.save_005fimage_jsp servlet, which listens on TCP port 8081 by default. When parsing the id parameter, the process does not properly validate user-supplied data, which can allow for the upload of files. An attacker can leverage this vulnerability to execute code under the context of Administrator. Was ZDI-CAN-5117."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-434",
              "description": "CWE-434-Unrestricted Upload of File with Dangerous Type",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-01-23T00:57:01.000Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://zerodayinitiative.com/advisories/ZDI-17-959"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "zdi-disclosures@trendmicro.com",
          "ID": "CVE-2017-16594",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "NetGain Systems Enterprise Manager",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "7.2.730 build 1034"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NetGain Systems"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "This vulnerability allows remote attackers to create arbitrary files on vulnerable installations of NetGain Systems Enterprise Manager 7.2.730 build 1034. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the org.apache.jsp.u.jsp.db.save_005fimage_jsp servlet, which listens on TCP port 8081 by default. When parsing the id parameter, the process does not properly validate user-supplied data, which can allow for the upload of files. An attacker can leverage this vulnerability to execute code under the context of Administrator. Was ZDI-CAN-5117."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-434-Unrestricted Upload of File with Dangerous Type"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://zerodayinitiative.com/advisories/ZDI-17-959",
              "refsource": "MISC",
              "url": "https://zerodayinitiative.com/advisories/ZDI-17-959"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2017-16594",
    "datePublished": "2018-01-23T01:00:00.000Z",
    "dateReserved": "2017-11-06T00:00:00.000Z",
    "dateUpdated": "2024-08-05T20:27:04.404Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-12332 (GCVE-0-2017-12332)

Vulnerability from cvelistv5 – Published: 2017-11-30 09:00 – Updated: 2024-08-05 18:36
VLAI
Summary
A vulnerability in Cisco NX-OS System Software patch installation could allow an authenticated, local attacker to write a file to arbitrary locations. The vulnerability is due to insufficient restrictions in the patch installation process. An attacker could exploit this vulnerability by installing a crafted patch image on an affected device. The vulnerable operation occurs prior to patch activation. An exploit could allow the attacker to write arbitrary files on an affected system as root. The attacker would need valid administrator credentials to perform this exploit. This vulnerability affects the following products running Cisco NX-OS System Software: Multilayer Director Switches, Nexus 2000 Series Fabric Extenders, Nexus 5000 Series Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Unified Computing System Manager. Cisco Bug IDs: CSCvf16513, CSCvf23794, CSCvf23832.
Severity
No CVSS data available.
CWE
Assigner
References
URL Tags
http://www.securityfocus.com/bid/102160 vdb-entryx_refsource_BID
https://tools.cisco.com/security/center/content/C… x_refsource_CONFIRM
http://www.securitytracker.com/id/1039931 vdb-entryx_refsource_SECTRACK
Impacted products
Vendor Product Version
n/a Cisco NX-OS Affected: Cisco NX-OS
Date Public
2017-11-30 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T18:36:55.269Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "102160",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/102160"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20171129-nxos1"
          },
          {
            "name": "1039931",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1039931"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Cisco NX-OS",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Cisco NX-OS"
            }
          ]
        }
      ],
      "datePublic": "2017-11-30T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in Cisco NX-OS System Software patch installation could allow an authenticated, local attacker to write a file to arbitrary locations. The vulnerability is due to insufficient restrictions in the patch installation process. An attacker could exploit this vulnerability by installing a crafted patch image on an affected device. The vulnerable operation occurs prior to patch activation. An exploit could allow the attacker to write arbitrary files on an affected system as root. The attacker would need valid administrator credentials to perform this exploit. This vulnerability affects the following products running Cisco NX-OS System Software: Multilayer Director Switches, Nexus 2000 Series Fabric Extenders, Nexus 5000 Series Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Unified Computing System Manager. Cisco Bug IDs: CSCvf16513, CSCvf23794, CSCvf23832."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-434",
              "description": "CWE-434",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-12-14T10:57:01.000Z",
        "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
        "shortName": "cisco"
      },
      "references": [
        {
          "name": "102160",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/102160"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20171129-nxos1"
        },
        {
          "name": "1039931",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1039931"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@cisco.com",
          "ID": "CVE-2017-12332",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Cisco NX-OS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Cisco NX-OS"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in Cisco NX-OS System Software patch installation could allow an authenticated, local attacker to write a file to arbitrary locations. The vulnerability is due to insufficient restrictions in the patch installation process. An attacker could exploit this vulnerability by installing a crafted patch image on an affected device. The vulnerable operation occurs prior to patch activation. An exploit could allow the attacker to write arbitrary files on an affected system as root. The attacker would need valid administrator credentials to perform this exploit. This vulnerability affects the following products running Cisco NX-OS System Software: Multilayer Director Switches, Nexus 2000 Series Fabric Extenders, Nexus 5000 Series Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Unified Computing System Manager. Cisco Bug IDs: CSCvf16513, CSCvf23794, CSCvf23832."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-434"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "102160",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/102160"
            },
            {
              "name": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20171129-nxos1",
              "refsource": "CONFIRM",
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20171129-nxos1"
            },
            {
              "name": "1039931",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id/1039931"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
    "assignerShortName": "cisco",
    "cveId": "CVE-2017-12332",
    "datePublished": "2017-11-30T09:00:00.000Z",
    "dateReserved": "2017-08-03T00:00:00.000Z",
    "dateUpdated": "2024-08-05T18:36:55.269Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-11154 (GCVE-0-2017-11154)

Vulnerability from cvelistv5 – Published: 2017-08-08 15:00 – Updated: 2024-09-17 00:26
VLAI
Summary
Unrestricted file upload vulnerability in PixlrEditorHandler.php in Synology Photo Station before 6.7.3-3432 and 6.3-2967 allows remote attackers to create arbitrary PHP scripts via the type parameter.
Severity
No CVSS data available.
CWE
  • CWE-434 - Unrestricted Upload of File with Dangerous Type (CWE-434)
Assigner
References
Impacted products
Vendor Product Version
Synology Synology Photo Station Affected: before 6.7.3-3432 and 6.3-2967
Create a notification for this product.
Date Public
2017-07-31 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T17:57:57.677Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.synology.com/en-global/support/security/Synology_SA_17_34_PhotoStation"
          },
          {
            "name": "42434",
            "tags": [
              "exploit",
              "x_refsource_EXPLOIT-DB",
              "x_transferred"
            ],
            "url": "https://www.exploit-db.com/exploits/42434/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Synology Photo Station",
          "vendor": "Synology",
          "versions": [
            {
              "status": "affected",
              "version": "before 6.7.3-3432 and 6.3-2967"
            }
          ]
        }
      ],
      "datePublic": "2017-07-31T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Unrestricted file upload vulnerability in PixlrEditorHandler.php in Synology Photo Station before 6.7.3-3432 and 6.3-2967 allows remote attackers to create arbitrary PHP scripts via the type parameter."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-434",
              "description": "Unrestricted Upload of File with Dangerous Type (CWE-434)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-08-11T15:57:01.000Z",
        "orgId": "db201096-a0cc-46c7-9a55-61d9e221bf01",
        "shortName": "synology"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.synology.com/en-global/support/security/Synology_SA_17_34_PhotoStation"
        },
        {
          "name": "42434",
          "tags": [
            "exploit",
            "x_refsource_EXPLOIT-DB"
          ],
          "url": "https://www.exploit-db.com/exploits/42434/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@synology.com",
          "DATE_PUBLIC": "2017-07-31T00:00:00",
          "ID": "CVE-2017-11154",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Synology Photo Station",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "before 6.7.3-3432 and 6.3-2967"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Synology"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Unrestricted file upload vulnerability in PixlrEditorHandler.php in Synology Photo Station before 6.7.3-3432 and 6.3-2967 allows remote attackers to create arbitrary PHP scripts via the type parameter."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Unrestricted Upload of File with Dangerous Type (CWE-434)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.synology.com/en-global/support/security/Synology_SA_17_34_PhotoStation",
              "refsource": "CONFIRM",
              "url": "https://www.synology.com/en-global/support/security/Synology_SA_17_34_PhotoStation"
            },
            {
              "name": "42434",
              "refsource": "EXPLOIT-DB",
              "url": "https://www.exploit-db.com/exploits/42434/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "db201096-a0cc-46c7-9a55-61d9e221bf01",
    "assignerShortName": "synology",
    "cveId": "CVE-2017-11154",
    "datePublished": "2017-08-08T15:00:00.000Z",
    "dateReserved": "2017-07-10T00:00:00.000Z",
    "dateUpdated": "2024-09-17T00:26:07.171Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-9650 (GCVE-0-2017-9650)

Vulnerability from cvelistv5 – Published: 2017-08-25 19:00 – Updated: 2024-08-05 17:18
VLAI
Summary
An Unrestricted Upload of File with Dangerous Type issue was discovered in Automated Logic Corporation (ALC) ALC WebCTRL, i-Vu, SiteScan Web 6.5 and prior; ALC WebCTRL, SiteScan Web 6.1 and prior; ALC WebCTRL, i-Vu 6.0 and prior; ALC WebCTRL, i-Vu, SiteScan Web 5.5 and prior; and ALC WebCTRL, i-Vu, SiteScan Web 5.2 and prior. An authenticated attacker may be able to upload a malicious file allowing the execution of arbitrary code.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Automated Logic Corporation WebCTRL, i-VU, SiteScan Affected: Automated Logic Corporation WebCTRL, i-VU, SiteScan
Date Public
2017-08-25 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T17:18:00.314Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "100452",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/100452"
          },
          {
            "name": "42544",
            "tags": [
              "exploit",
              "x_refsource_EXPLOIT-DB",
              "x_transferred"
            ],
            "url": "https://www.exploit-db.com/exploits/42544/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-234-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Automated Logic Corporation WebCTRL, i-VU, SiteScan",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Automated Logic Corporation WebCTRL, i-VU, SiteScan"
            }
          ]
        }
      ],
      "datePublic": "2017-08-25T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Unrestricted Upload of File with Dangerous Type issue was discovered in Automated Logic Corporation (ALC) ALC WebCTRL, i-Vu, SiteScan Web 6.5 and prior; ALC WebCTRL, SiteScan Web 6.1 and prior; ALC WebCTRL, i-Vu 6.0 and prior; ALC WebCTRL, i-Vu, SiteScan Web 5.5 and prior; and ALC WebCTRL, i-Vu, SiteScan Web 5.2 and prior. An authenticated attacker may be able to upload a malicious file allowing the execution of arbitrary code."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-434",
              "description": "CWE-434",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-08-26T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "100452",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/100452"
        },
        {
          "name": "42544",
          "tags": [
            "exploit",
            "x_refsource_EXPLOIT-DB"
          ],
          "url": "https://www.exploit-db.com/exploits/42544/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-234-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-9650",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Automated Logic Corporation WebCTRL, i-VU, SiteScan",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Automated Logic Corporation WebCTRL, i-VU, SiteScan"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Unrestricted Upload of File with Dangerous Type issue was discovered in Automated Logic Corporation (ALC) ALC WebCTRL, i-Vu, SiteScan Web 6.5 and prior; ALC WebCTRL, SiteScan Web 6.1 and prior; ALC WebCTRL, i-Vu 6.0 and prior; ALC WebCTRL, i-Vu, SiteScan Web 5.5 and prior; and ALC WebCTRL, i-Vu, SiteScan Web 5.2 and prior. An authenticated attacker may be able to upload a malicious file allowing the execution of arbitrary code."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-434"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "100452",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/100452"
            },
            {
              "name": "42544",
              "refsource": "EXPLOIT-DB",
              "url": "https://www.exploit-db.com/exploits/42544/"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-234-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-234-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-9650",
    "datePublished": "2017-08-25T19:00:00.000Z",
    "dateReserved": "2017-06-14T00:00:00.000Z",
    "dateUpdated": "2024-08-05T17:18:00.314Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-9279 (GCVE-0-2017-9279)

Vulnerability from cvelistv5 – Published: 2018-03-02 20:00 – Updated: 2024-09-17 00:35
VLAI
Title
NetIQ Identity Manager allowed uploading of user icons with incorrect types or extensions
Summary
NetIQ Identity Manager before 4.5.6.1 allowed uploading files with double extensions or non-image content in the Themes handling of the User Application Administration, allowing malicious user administrators to potentially execute code or mislead users.
CWE
  • Upload of files possible that could be misused for other purposes
  • CWE-434
Assigner
References
Impacted products
Vendor Product Version
NetIQ Identity Manager Affected: unspecified , < 4.5.6.1 (custom)
Create a notification for this product.
Date Public
2017-09-11 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T17:02:44.187Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://download.novell.com/Download?buildid=K7lbPAGJyIk~"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://bugzilla.suse.com/show_bug.cgi?id=1049129"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Identity Manager",
          "vendor": "NetIQ",
          "versions": [
            {
              "lessThan": "4.5.6.1",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2017-09-11T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "NetIQ Identity Manager before 4.5.6.1 allowed uploading files with double extensions or non-image content in the Themes handling of the User Application Administration, allowing malicious user administrators to potentially execute code or mislead users."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 2,
            "baseSeverity": "LOW",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Upload of files possible that could be misused for other purposes",
              "lang": "en",
              "type": "text"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-434",
              "description": "CWE-434",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-06T16:15:51.000Z",
        "orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
        "shortName": "microfocus"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://download.novell.com/Download?buildid=K7lbPAGJyIk~"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://bugzilla.suse.com/show_bug.cgi?id=1049129"
        }
      ],
      "source": {
        "advisory": "2017-09-11",
        "defect": [
          "1049129"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "NetIQ Identity Manager allowed uploading of user icons with incorrect types or extensions",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@microfocus.com",
          "DATE_PUBLIC": "2017-09-11T00:00:00.000Z",
          "ID": "CVE-2017-9279",
          "STATE": "PUBLIC",
          "TITLE": "NetIQ Identity Manager allowed uploading of user icons with incorrect types or extensions"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Identity Manager",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c",
                            "version_affected": "\u003c",
                            "version_value": "4.5.6.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NetIQ"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "NetIQ Identity Manager before 4.5.6.1 allowed uploading files with double extensions or non-image content in the Themes handling of the User Application Administration, allowing malicious user administrators to potentially execute code or mislead users."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 2,
            "baseSeverity": "LOW",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Upload of files possible that could be misused for other purposes"
                }
              ]
            },
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-434"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://download.novell.com/Download?buildid=K7lbPAGJyIk~",
              "refsource": "CONFIRM",
              "url": "https://download.novell.com/Download?buildid=K7lbPAGJyIk~"
            },
            {
              "name": "https://bugzilla.suse.com/show_bug.cgi?id=1049129",
              "refsource": "CONFIRM",
              "url": "https://bugzilla.suse.com/show_bug.cgi?id=1049129"
            }
          ]
        },
        "source": {
          "advisory": "2017-09-11",
          "defect": [
            "1049129"
          ],
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
    "assignerShortName": "microfocus",
    "cveId": "CVE-2017-9279",
    "datePublished": "2018-03-02T20:00:00.000Z",
    "dateReserved": "2017-05-29T00:00:00.000Z",
    "dateUpdated": "2024-09-17T00:35:46.737Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-7429 (GCVE-0-2017-7429)

Vulnerability from cvelistv5 – Published: 2018-03-02 20:00 – Updated: 2024-09-16 23:35
VLAI
Title
Fix for NetIQ shell code upload
Summary
The certificate upload in NetIQ eDirectory PKI plugin before 8.8.8 Patch 10 Hotfix 1 could be abused to upload JSP code which could be used by authenticated attackers to execute JSP applets on the iManager server.
CWE
Assigner
Impacted products
Vendor Product Version
NetIQ eDirectory Affected: unspecified , < 8.8.8 Patch 10 HF1 (custom)
Create a notification for this product.
Date Public
2017-10-02 00:00
Credits
SySS GmbH
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:04:11.244Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://bugzilla.suse.com/show_bug.cgi?id=1024957"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.novell.com/support/kb/doc.php?id=3426981"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.netiq.com/documentation/edir88/edir88810hf1_releasenotes/data/edir88810hf1_releasenotes.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "eDirectory",
          "vendor": "NetIQ",
          "versions": [
            {
              "lessThan": "8.8.8 Patch 10 HF1",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "SySS GmbH"
        }
      ],
      "datePublic": "2017-10-02T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "The certificate upload in NetIQ eDirectory PKI plugin before 8.8.8 Patch 10 Hotfix 1 could be abused to upload JSP code which could be used by authenticated attackers to execute JSP applets on the iManager server."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-434",
              "description": "CWE-434",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-06T16:15:34.000Z",
        "orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
        "shortName": "microfocus"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://bugzilla.suse.com/show_bug.cgi?id=1024957"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.novell.com/support/kb/doc.php?id=3426981"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.netiq.com/documentation/edir88/edir88810hf1_releasenotes/data/edir88810hf1_releasenotes.html"
        }
      ],
      "source": {
        "defect": [
          "1024957"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "Fix for NetIQ shell code upload",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@suse.com",
          "DATE_PUBLIC": "2017-10-02T00:00:00.000Z",
          "ID": "CVE-2017-7429",
          "STATE": "PUBLIC",
          "TITLE": "Fix for NetIQ shell code upload"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "eDirectory",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c",
                            "version_affected": "\u003c",
                            "version_value": "8.8.8 Patch 10 HF1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NetIQ"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "SySS GmbH"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The certificate upload in NetIQ eDirectory PKI plugin before 8.8.8 Patch 10 Hotfix 1 could be abused to upload JSP code which could be used by authenticated attackers to execute JSP applets on the iManager server."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-434"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://bugzilla.suse.com/show_bug.cgi?id=1024957",
              "refsource": "CONFIRM",
              "url": "https://bugzilla.suse.com/show_bug.cgi?id=1024957"
            },
            {
              "name": "https://www.novell.com/support/kb/doc.php?id=3426981",
              "refsource": "CONFIRM",
              "url": "https://www.novell.com/support/kb/doc.php?id=3426981"
            },
            {
              "name": "https://www.netiq.com/documentation/edir88/edir88810hf1_releasenotes/data/edir88810hf1_releasenotes.html",
              "refsource": "CONFIRM",
              "url": "https://www.netiq.com/documentation/edir88/edir88810hf1_releasenotes/data/edir88810hf1_releasenotes.html"
            }
          ]
        },
        "source": {
          "defect": [
            "1024957"
          ],
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
    "assignerShortName": "microfocus",
    "cveId": "CVE-2017-7429",
    "datePublished": "2018-03-02T20:00:00.000Z",
    "dateReserved": "2017-04-05T00:00:00.000Z",
    "dateUpdated": "2024-09-16T23:35:59.724Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-6041 (GCVE-0-2017-6041)

Vulnerability from cvelistv5 – Published: 2017-06-30 02:35 – Updated: 2024-08-05 15:18
VLAI
Summary
An Unrestricted Upload issue was discovered in Marel Food Processing Systems M3000 terminal associated with the following systems: A320, A325, A371, A520 Master, A520 Slave, A530, A542, A571, Check Bin Grader, FlowlineQC T376, IPM3 Dual Cam v132, IPM3 Dual Cam v139, IPM3 Single Cam v132, P520, P574, SensorX13 QC flow line, SensorX23 QC Master, SensorX23 QC Slave, Speed Batcher, T374, T377, V36, V36B, and V36C; M3210 terminal associated with the same systems as the M3000 terminal identified above; M3000 desktop software associated with the same systems as the M3000 terminal identified above; MAC4 controller associated with the same systems as the M3000 terminal identified above; SensorX23 X-ray machine; SensorX25 X-ray machine; and MWS2 weighing system. This vulnerability allows an attacker to modify the operation and upload firmware changes without detection.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Marel Food Processing Systems Affected: Marel Food Processing Systems
Date Public
2017-06-29 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T15:18:49.755Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "97388",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/97388"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-094-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Marel Food Processing Systems",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Marel Food Processing Systems"
            }
          ]
        }
      ],
      "datePublic": "2017-06-29T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Unrestricted Upload issue was discovered in Marel Food Processing Systems M3000 terminal associated with the following systems: A320, A325, A371, A520 Master, A520 Slave, A530, A542, A571, Check Bin Grader, FlowlineQC T376, IPM3 Dual Cam v132, IPM3 Dual Cam v139, IPM3 Single Cam v132, P520, P574, SensorX13 QC flow line, SensorX23 QC Master, SensorX23 QC Slave, Speed Batcher, T374, T377, V36, V36B, and V36C; M3210 terminal associated with the same systems as the M3000 terminal identified above; M3000 desktop software associated with the same systems as the M3000 terminal identified above; MAC4 controller associated with the same systems as the M3000 terminal identified above; SensorX23 X-ray machine; SensorX25 X-ray machine; and MWS2 weighing system. This vulnerability allows an attacker to modify the operation and upload firmware changes without detection."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-434",
              "description": "CWE-434",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-06-30T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "97388",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/97388"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-094-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-6041",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Marel Food Processing Systems",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Marel Food Processing Systems"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Unrestricted Upload issue was discovered in Marel Food Processing Systems M3000 terminal associated with the following systems: A320, A325, A371, A520 Master, A520 Slave, A530, A542, A571, Check Bin Grader, FlowlineQC T376, IPM3 Dual Cam v132, IPM3 Dual Cam v139, IPM3 Single Cam v132, P520, P574, SensorX13 QC flow line, SensorX23 QC Master, SensorX23 QC Slave, Speed Batcher, T374, T377, V36, V36B, and V36C; M3210 terminal associated with the same systems as the M3000 terminal identified above; M3000 desktop software associated with the same systems as the M3000 terminal identified above; MAC4 controller associated with the same systems as the M3000 terminal identified above; SensorX23 X-ray machine; SensorX25 X-ray machine; and MWS2 weighing system. This vulnerability allows an attacker to modify the operation and upload firmware changes without detection."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-434"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "97388",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/97388"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-094-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-094-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-6041",
    "datePublished": "2017-06-30T02:35:00.000Z",
    "dateReserved": "2017-02-16T00:00:00.000Z",
    "dateUpdated": "2024-08-05T15:18:49.755Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-6027 (GCVE-0-2017-6027)

Vulnerability from cvelistv5 – Published: 2017-05-19 02:43 – Updated: 2024-08-05 15:18
VLAI
Summary
An Arbitrary File Upload issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A specially crafted web server request may allow the upload of arbitrary files (with a dangerous type) to the CODESYS Web Server without authorization which may allow remote code execution.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a 3S-Smart Software Solutions GmbH CODESYS Web Server Affected: 3S-Smart Software Solutions GmbH CODESYS Web Server
Date Public
2017-05-18 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T15:18:49.577Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "97174",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/97174"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-087-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "3S-Smart Software Solutions GmbH CODESYS Web Server",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "3S-Smart Software Solutions GmbH CODESYS Web Server"
            }
          ]
        }
      ],
      "datePublic": "2017-05-18T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Arbitrary File Upload issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A specially crafted web server request may allow the upload of arbitrary files (with a dangerous type) to the CODESYS Web Server without authorization which may allow remote code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-434",
              "description": "CWE-434",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-05-19T09:57:02.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "97174",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/97174"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-087-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-6027",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "3S-Smart Software Solutions GmbH CODESYS Web Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "3S-Smart Software Solutions GmbH CODESYS Web Server"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Arbitrary File Upload issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A specially crafted web server request may allow the upload of arbitrary files (with a dangerous type) to the CODESYS Web Server without authorization which may allow remote code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-434"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "97174",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/97174"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-087-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-087-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-6027",
    "datePublished": "2017-05-19T02:43:00.000Z",
    "dateReserved": "2017-02-16T00:00:00.000Z",
    "dateUpdated": "2024-08-05T15:18:49.577Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation
Architecture and Design

Generate a new, unique filename for an uploaded file instead of using the user-supplied filename, so that no external input is used at all.[REF-422] [REF-423]

Mitigation MIT-21
Architecture and Design

Strategy: Enforcement by Conversion

When the set of acceptable objects, such as filenames or URLs, is limited or known, create a mapping from a set of fixed input values (such as numeric IDs) to the actual filenames or URLs, and reject all other inputs.

Mitigation
Architecture and Design

Consider storing the uploaded files outside of the web document root entirely. Then, use other mechanisms to deliver the files dynamically. [REF-423]

Mitigation MIT-5
Implementation

Strategy: Input Validation

  • Assume all input is malicious. Use an "accept known good" input validation strategy, i.e., use a list of acceptable inputs that strictly conform to specifications. Reject any input that does not strictly conform to specifications, or transform it into something that does.
  • When performing input validation, consider all potentially relevant properties, including length, type of input, the full range of acceptable values, missing or extra inputs, syntax, consistency across related fields, and conformance to business rules. As an example of business rule logic, "boat" may be syntactically valid because it only contains alphanumeric characters, but it is not valid if the input is only expected to contain colors such as "red" or "blue."
  • Do not rely exclusively on looking for malicious or malformed inputs. This is likely to miss at least one undesirable input, especially if the code's environment changes. This can give attackers enough room to bypass the intended validation. However, denylists can be useful for detecting potential attacks or determining which inputs are so malformed that they should be rejected outright.
  • For example, limiting filenames to alphanumeric characters can help to restrict the introduction of unintended file extensions.
Mitigation
Architecture and Design

Define a very limited set of allowable extensions and only generate filenames that end in these extensions. Consider the possibility of XSS (CWE-79) before allowing .html or .htm file types.

Mitigation
Implementation

Strategy: Input Validation

Ensure that only one extension is used in the filename. Some web servers, including some versions of Apache, may process files based on inner extensions so that "filename.php.gif" is fed to the PHP interpreter.[REF-422] [REF-423]

Mitigation
Implementation

When running on a web server that supports case-insensitive filenames, perform case-insensitive evaluations of the extensions that are provided.

Mitigation MIT-15
Architecture and Design

For any security checks that are performed on the client side, ensure that these checks are duplicated on the server side, in order to avoid CWE-602. Attackers can bypass the client-side checks by modifying values after the checks have been performed, or by changing the client to remove the client-side checks entirely. Then, these modified values would be submitted to the server.

Mitigation
Implementation

Do not rely exclusively on sanity checks of file contents to ensure that the file is of the expected type and size. It may be possible for an attacker to hide code in some file segments that will still be executed by the server. For example, GIF images may contain a free-form comments field.

Mitigation
Implementation

Do not rely exclusively on the MIME content type or filename attribute when determining how to render a file. Validating the MIME content type and ensuring that it matches the extension is only a partial solution.

Mitigation MIT-17
Architecture and Design Operation

Strategy: Environment Hardening

Run your code using the lowest privileges that are required to accomplish the necessary tasks [REF-76]. If possible, create isolated accounts with limited privileges that are only used for a single task. That way, a successful attack will not immediately give the attacker access to the rest of the software or its environment. For example, database applications rarely need to run as the database administrator, especially in day-to-day operations.

Mitigation MIT-22
Architecture and Design Operation

Strategy: Sandbox or Jail

  • Run the code in a "jail" or similar sandbox environment that enforces strict boundaries between the process and the operating system. This may effectively restrict which files can be accessed in a particular directory or which commands can be executed by the software.
  • OS-level examples include the Unix chroot jail, AppArmor, and SELinux. In general, managed code may provide some protection. For example, java.io.FilePermission in the Java SecurityManager allows the software to specify restrictions on file operations.
  • This may not be a feasible solution, and it only limits the impact to the operating system; the rest of the application may still be subject to compromise.
  • Be careful to avoid CWE-243 and other weaknesses related to jails.
CAPEC-1: Accessing Functionality Not Properly Constrained by ACLs

In applications, particularly web applications, access to functionality is mitigated by an authorization framework. This framework maps Access Control Lists (ACLs) to elements of the application's functionality; particularly URL's for web apps. In the case that the administrator failed to specify an ACL for a particular element, an attacker may be able to access it with impunity. An attacker with the ability to access functionality not properly constrained by ACLs can obtain sensitive information and possibly compromise the entire application. Such an attacker can access resources that must be available only to users at a higher privilege level, can access management sections of the application, or can run queries for data that they otherwise not supposed to.