Common Weakness Enumeration

CWE-312

Allowed

Cleartext Storage of Sensitive Information

Abstraction: Base · Status: Draft

The product stores sensitive information in cleartext within a resource that might be accessible to another control sphere.

1017 vulnerabilities reference this CWE, most recent first.

CVE-2022-4312 (GCVE-0-2022-4312)

Vulnerability from cvelistv5 – Published: 2022-12-12 17:10 – Updated: 2025-04-14 18:00
VLAI
Summary
A cleartext storage of sensitive information vulnerability exists in PcVue versions 8.10 through 15.2.3. This could allow an unauthorized user with access the email and short messaging service (SMS) accounts configuration files to discover the associated simple mail transfer protocol (SMTP) account credentials and the SIM card PIN code. Successful exploitation of this vulnerability could allow an unauthorized user access to the underlying email account and SIM card.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
Impacted products
Vendor Product Version
ARC Informatique PcVue Affected: 8.10 , ≤ 15.2.3 (custom)
Create a notification for this product.
Credits
ARC Informatique
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T01:34:50.159Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.pcvuesolutions.com/support/index.php/en/security-bulletin/1171-security-bulletin-2022-7"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-4312",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-14T17:44:58.764003Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-14T18:00:16.760Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PcVue",
          "vendor": "ARC Informatique",
          "versions": [
            {
              "lessThanOrEqual": "15.2.3",
              "status": "affected",
              "version": "8.10",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "ARC Informatique"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nA cleartext storage of sensitive information vulnerability exists in PcVue versions 8.10 through 15.2.3. This could\nallow an unauthorized user with access the email and short messaging service (SMS) accounts configuration files\nto discover the associated simple mail transfer protocol (SMTP) account credentials and the SIM card PIN code.\nSuccessful exploitation of this vulnerability could allow an unauthorized user access to the underlying email\naccount and SIM card.\n\n"
            }
          ],
          "value": "\nA cleartext storage of sensitive information vulnerability exists in PcVue versions 8.10 through 15.2.3. This could\nallow an unauthorized user with access the email and short messaging service (SMS) accounts configuration files\nto discover the associated simple mail transfer protocol (SMTP) account credentials and the SIM card PIN code.\nSuccessful exploitation of this vulnerability could allow an unauthorized user access to the underlying email\naccount and SIM card.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312 Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-12T17:10:22.202Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.pcvuesolutions.com/support/index.php/en/security-bulletin/1171-security-bulletin-2022-7"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-4312",
    "datePublished": "2022-12-12T17:10:22.202Z",
    "dateReserved": "2022-12-06T19:08:58.863Z",
    "dateUpdated": "2025-04-14T18:00:16.760Z",
    "requesterUserId": "4bacbe59-ded0-410b-af09-0c6f387b5ddc",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2813 (GCVE-0-2022-2813)

Vulnerability from cvelistv5 – Published: 2022-08-14 10:16 – Updated: 2025-04-15 13:50
VLAI
Title
SourceCodester Guest Management System cleartext storage
Summary
A vulnerability, which was classified as problematic, was found in SourceCodester Guest Management System. Affected is an unknown function. The manipulation leads to cleartext storage of passwords in the database. The identifier of this vulnerability is VDB-206400.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
URL Tags
https://vuldb.com/?id.206400 x_refsource_MISC
Impacted products
Credits
Marc Ruef
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:52:59.263Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.206400"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2813",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-14T17:10:29.505215Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-15T13:50:06.726Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Guest Management System",
          "vendor": "SourceCodester",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Marc Ruef"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as problematic, was found in SourceCodester Guest Management System. Affected is an unknown function. The manipulation leads to cleartext storage of passwords in the database. The identifier of this vulnerability is VDB-206400."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312 Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-14T10:16:12.000Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://vuldb.com/?id.206400"
        }
      ],
      "title": "SourceCodester Guest Management System cleartext storage",
      "x_generator": "vuldb.com",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cna@vuldb.com",
          "ID": "CVE-2022-2813",
          "REQUESTER": "cna@vuldb.com",
          "STATE": "PUBLIC",
          "TITLE": "SourceCodester Guest Management System cleartext storage"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Guest Management System",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "SourceCodester"
              }
            ]
          }
        },
        "credit": "Marc Ruef",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability, which was classified as problematic, was found in SourceCodester Guest Management System. Affected is an unknown function. The manipulation leads to cleartext storage of passwords in the database. The identifier of this vulnerability is VDB-206400."
            }
          ]
        },
        "generator": "vuldb.com",
        "impact": {
          "cvss": {
            "baseScore": "4.3",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312 Cleartext Storage of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://vuldb.com/?id.206400",
              "refsource": "MISC",
              "url": "https://vuldb.com/?id.206400"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2022-2813",
    "datePublished": "2022-08-14T10:16:12.000Z",
    "dateReserved": "2022-08-14T00:00:00.000Z",
    "dateUpdated": "2025-04-15T13:50:06.726Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2805 (GCVE-0-2022-2805)

Vulnerability from cvelistv5 – Published: 2022-10-19 00:00 – Updated: 2025-05-09 14:33
VLAI
Summary
A flaw was found in ovirt-engine, which leads to the logging of plaintext passwords in the log file when using otapi-style. This flaw allows an attacker with sufficient privileges to read the log file, leading to confidentiality loss.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
Impacted products
Vendor Product Version
n/a ovirt-engine Affected: ovirt-engine 4.5.3
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:52:58.892Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://bugzilla.redhat.com/show_bug.cgi?id=2079545"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://access.redhat.com/security/cve/CVE-2022-2805"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-2805",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-09T14:32:32.520420Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-09T14:33:34.709Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ovirt-engine",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "ovirt-engine 4.5.3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw was found in ovirt-engine, which leads to the logging of plaintext passwords in the log file when using otapi-style. This flaw allows an attacker with sufficient privileges to read the log file, leading to confidentiality loss."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-10-24T00:00:00.000Z",
        "orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
        "shortName": "redhat"
      },
      "references": [
        {
          "url": "https://bugzilla.redhat.com/show_bug.cgi?id=2079545"
        },
        {
          "url": "https://access.redhat.com/security/cve/CVE-2022-2805"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
    "assignerShortName": "redhat",
    "cveId": "CVE-2022-2805",
    "datePublished": "2022-10-19T00:00:00.000Z",
    "dateReserved": "2022-08-12T00:00:00.000Z",
    "dateUpdated": "2025-05-09T14:33:34.709Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2569 (GCVE-0-2022-2569)

Vulnerability from cvelistv5 – Published: 2022-08-24 15:16 – Updated: 2025-04-16 16:11
VLAI
Title
ARC Informatique PcVue
Summary
The affected device stores sensitive information in cleartext, which may allow an authenticated user to access session data stored in the OAuth database belonging to legitimate users
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
Date Public
2022-08-23 00:00
Credits
An unnamed researcher reported this vulnerability to ARC Informatique.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:39:08.065Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-01-0"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2569",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:50:26.795107Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T16:11:59.819Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PcVue 12 OAuth web service configuration",
          "vendor": "ARC Informatique",
          "versions": [
            {
              "lessThan": "12.0.27",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "PcVue 15 OAuth web service configuration",
          "vendor": "ARC Informatique",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "An unnamed researcher reported this vulnerability to ARC Informatique."
        }
      ],
      "datePublic": "2022-08-23T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "The affected device stores sensitive information in cleartext, which may allow an authenticated user to access session data stored in the OAuth database belonging to legitimate users"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312 Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-24T15:16:15.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-01-0"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "PcVue 12: The fix is available in Maintenance release 12.0.27\nAfter installing the fix, users should update the Web Deployment Console (WDC) and re-deploy the Web Server. \nAll users using the affected component should install a patched release of the WDC and re-deploy the Web Server. This will allow the WDC to update and protect the database connection string, including clearing any sensitive information stored in the web.config file."
        }
      ],
      "source": {
        "advisory": "ICSA-22-235-01",
        "discovery": "UNKNOWN"
      },
      "title": "ARC Informatique PcVue",
      "workarounds": [
        {
          "lang": "en",
          "value": "ARC Informatique has identified additional steps users can apply to reduce the risk:\n\nUninstall the Web Server\nAll users not using the affected component should uninstall the web server. The OAuth web service and its configuration are part of the Web Server for PcVue. If the system does not require Web \u0026 Mobile features, then users should not install them.\nUsers should contact ARC Informatique\u2019s PcVue Solutions for assistance with the above steps.\n\nFor additional information, visit the public ARC Informatique security alert page."
        },
        {
          "lang": "en",
          "value": "PcVue 15 does not have a fix released yet, but is in the works."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2022-08-23T17:00:00.000Z",
          "ID": "CVE-2022-2569",
          "STATE": "PUBLIC",
          "TITLE": "ARC Informatique PcVue"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PcVue 12 OAuth web service configuration",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "All",
                            "version_value": "12.0.27"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PcVue 15 OAuth web service configuration",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "All",
                            "version_value": "All"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ARC Informatique"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "An unnamed researcher reported this vulnerability to ARC Informatique."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The affected device stores sensitive information in cleartext, which may allow an authenticated user to access session data stored in the OAuth database belonging to legitimate users"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312 Cleartext Storage of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-01-0",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-01-0"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "PcVue 12: The fix is available in Maintenance release 12.0.27\nAfter installing the fix, users should update the Web Deployment Console (WDC) and re-deploy the Web Server. \nAll users using the affected component should install a patched release of the WDC and re-deploy the Web Server. This will allow the WDC to update and protect the database connection string, including clearing any sensitive information stored in the web.config file."
          }
        ],
        "source": {
          "advisory": "ICSA-22-235-01",
          "discovery": "UNKNOWN"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "ARC Informatique has identified additional steps users can apply to reduce the risk:\n\nUninstall the Web Server\nAll users not using the affected component should uninstall the web server. The OAuth web service and its configuration are part of the Web Server for PcVue. If the system does not require Web \u0026 Mobile features, then users should not install them.\nUsers should contact ARC Informatique\u2019s PcVue Solutions for assistance with the above steps.\n\nFor additional information, visit the public ARC Informatique security alert page."
          },
          {
            "lang": "en",
            "value": "PcVue 15 does not have a fix released yet, but is in the works."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-2569",
    "datePublished": "2022-08-24T15:16:15.430Z",
    "dateReserved": "2022-07-28T00:00:00.000Z",
    "dateUpdated": "2025-04-16T16:11:59.819Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2513 (GCVE-0-2022-2513)

Vulnerability from cvelistv5 – Published: 2022-11-22 10:30 – Updated: 2025-08-27 20:32
VLAI
Title
Cleartext Credentials Vulnerability on Hitachi Energy’s Multiple IED Connectivity Packages (IED ConnPacks) and PCM600 Products
Summary
A vulnerability exists in the Intelligent Electronic Device (IED) Connectivity Package (ConnPack) credential storage function in Hitachi Energy’s PCM600 product included in the versions listed below, where IEDs credentials are stored in a cleartext format in the PCM600 database and logs files. An attacker having get access to the exported backup file can exploit the vulnerability and obtain user credentials of the IEDs. Additionally, an attacker with administrator access to the PCM600 host machine can obtain other user credentials by analyzing database log files. The credentials may be used to perform unauthorized modifications such as loading incorrect configurations, reboot the IEDs or cause a denial-of-service on the IEDs.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information
Assigner
Date Public
2022-11-15 13:30
Credits
PSE - Polskie Sieci Elektroenergetyczne (Polish Power Grid Company (PPGC))
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:39:08.068Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000120\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2513",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-25T20:57:36.531395Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-27T20:32:51.508Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PCM600",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "lessThanOrEqual": "2.11 Hotfix 20220617",
              "status": "affected",
              "version": "v2.6",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "670 Connectivity Package",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "lessThanOrEqual": "3.4.1",
              "status": "affected",
              "version": "3.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "650 Connectivity Package",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "lessThanOrEqual": "2.4.1",
              "status": "affected",
              "version": "1.3",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SAM600-IO Connectivity Package",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "lessThanOrEqual": "1.2",
              "status": "affected",
              "version": "1.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GMS600 Connectivity Package",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "lessThanOrEqual": "1.3.1",
              "status": "affected",
              "version": "1.3",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PWC600 Connectivity Package",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "lessThanOrEqual": "1.3",
              "status": "affected",
              "version": "1.1",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "PSE - Polskie Sieci Elektroenergetyczne (Polish Power Grid Company (PPGC))"
        }
      ],
      "datePublic": "2022-11-15T13:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability exists in the Intelligent Electronic Device (IED) Connectivity Package (ConnPack) credential storage function in Hitachi Energy\u2019s PCM600 product included in the versions listed below, where IEDs credentials are stored in a cleartext format in the PCM600 database and logs files. An attacker having get access to the exported backup file can exploit the vulnerability and obtain user credentials of the IEDs. Additionally, an attacker with administrator access to the PCM600 host machine can obtain other user credentials by analyzing database log files. The credentials may be used to perform unauthorized modifications such as loading incorrect configurations, reboot the IEDs or cause a denial-of-service on the IEDs.\u003cbr\u003e\u003cbr\u003e"
            }
          ],
          "value": "A vulnerability exists in the Intelligent Electronic Device (IED) Connectivity Package (ConnPack) credential storage function in Hitachi Energy\u2019s PCM600 product included in the versions listed below, where IEDs credentials are stored in a cleartext format in the PCM600 database and logs files. An attacker having get access to the exported backup file can exploit the vulnerability and obtain user credentials of the IEDs. Additionally, an attacker with administrator access to the PCM600 host machine can obtain other user credentials by analyzing database log files. The credentials may be used to perform unauthorized modifications such as loading incorrect configurations, reboot the IEDs or cause a denial-of-service on the IEDs."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312 Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-28T10:20:49.089Z",
        "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "shortName": "Hitachi Energy"
      },
      "references": [
        {
          "url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000120\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Update to PCM600 v2.11 Hotfix 20240426 or apply mitigation\nfactors/workarounds as described in the Mitigation Factors/Workarounds Section.\u003cbr\u003e\u003cbr\u003eList of CPEs:\u0026nbsp;\u003cbr\u003ecpe:2.3:a:hitachienergy:pcm600:*:*:*:*:*:*:*:*\u003cbr\u003e\u003cbr\u003ecpe:2.3:a:hitachienergy:670ConnectivityPackage:3.4.1:*:*:*:*:*:*:*\u003cbr\u003e\n\ncpe:2.3:a:hitachienergy:670ConnectivityPackage:3.3.0:*:*:*:*:*:*:*\n\u003cbr\u003e\n\n\ncpe:2.3:a:hitachienergy:670ConnectivityPackage:3.2.6:*:*:*:*:*:*:*\n\n\u003cbr\u003e\n\ncpe:2.3:a:hitachienergy:670ConnectivityPackage:3.1.2:*:*:*:*:*:*:*\u003cbr\u003e\n\n\n\ncpe:2.3:a:hitachienergy:670ConnectivityPackage:3.0.2:*:*:*:*:*:*:*\u003cbr\u003e\n\n\u003cbr\u003ecpe:2.3:a:hitachienergy:650ConnectivityPackage:2.4.1:*:*:*:*:*:*:*\u003cbr\u003e\n\ncpe:2.3:a:hitachienergy:650ConnectivityPackage:2.3.0:*:*:*:*:*:*:*\u003cbr\u003e\n\n\n\ncpe:2.3:a:hitachienergy:650ConnectivityPackage:2.2.2:*:*:*:*:*:*:*\u003cbr\u003e\n\n\n\ncpe:2.3:a:hitachienergy:650ConnectivityPackage:2.1.2:*:*:*:*:*:*:*\u003cbr\u003e\n\n\n\ncpe:2.3:a:hitachienergy:650ConnectivityPackage:1.3.0:*:*:*:*:*:*:*\u003cbr\u003e\n\n\u003cbr\u003ecpe:2.3:a:hitachienergy:sam600ioConnectivityPackage:1.2.0:*:*:*:*:*:*:*\u003cbr\u003e\n\ncpe:2.3:a:hitachienergy:sam600ioConnectivityPackage:1.1.0:*:*:*:*:*:*:*\u003cbr\u003e\n\n\n\ncpe:2.3:a:hitachienergy:sam600ioConnectivityPackage:1.0.0:*:*:*:*:*:*:*\n\n\u003cbr\u003e\u003cbr\u003ecpe:2.3:a:hitachienergy:pwc600ConnectivityPackage:1.3.0:*:*:*:*:*:*:*\u003cbr\u003e\n\ncpe:2.3:a:hitachienergy:pwc600ConnectivityPackage:1.2.0:*:*:*:*:*:*:*\n\n\u003cbr\u003e\n\ncpe:2.3:a:hitachienergy:pwc600ConnectivityPackage:1.1.2:*:*:*:*:*:*:*\n\n\u003cbr\u003e\n\ncpe:2.3:a:hitachienergy:pwc600ConnectivityPackage:1.1.1:*:*:*:*:*:*:*\n\n\u003cbr\u003e\n\ncpe:2.3:a:hitachienergy:pwc600ConnectivityPackage:1.1.0:*:*:*:*:*:*:*\n\n\u003cbr\u003e\u003cbr\u003ecpe:2.3:a:hitachienergy:gms600ConnectivityPackage:1.3.1:*:*:*:*:*:*:*\u003cbr\u003e\n\ncpe:2.3:a:hitachienergy:gms600ConnectivityPackage:1.3.0:*:*:*:*:*:*:*\n\n\u003cbr\u003e \n\n\u003cbr\u003e"
            }
          ],
          "value": "Update to PCM600 v2.11 Hotfix 20240426 or apply mitigation\nfactors/workarounds as described in the Mitigation Factors/Workarounds Section.\n\nList of CPEs:\u00a0\ncpe:2.3:a:hitachienergy:pcm600:*:*:*:*:*:*:*:*\n\ncpe:2.3:a:hitachienergy:670ConnectivityPackage:3.4.1:*:*:*:*:*:*:*\n\n\ncpe:2.3:a:hitachienergy:670ConnectivityPackage:3.3.0:*:*:*:*:*:*:*\n\n\n\n\ncpe:2.3:a:hitachienergy:670ConnectivityPackage:3.2.6:*:*:*:*:*:*:*\n\n\n\n\ncpe:2.3:a:hitachienergy:670ConnectivityPackage:3.1.2:*:*:*:*:*:*:*\n\n\n\n\ncpe:2.3:a:hitachienergy:670ConnectivityPackage:3.0.2:*:*:*:*:*:*:*\n\n\n\ncpe:2.3:a:hitachienergy:650ConnectivityPackage:2.4.1:*:*:*:*:*:*:*\n\n\ncpe:2.3:a:hitachienergy:650ConnectivityPackage:2.3.0:*:*:*:*:*:*:*\n\n\n\n\ncpe:2.3:a:hitachienergy:650ConnectivityPackage:2.2.2:*:*:*:*:*:*:*\n\n\n\n\ncpe:2.3:a:hitachienergy:650ConnectivityPackage:2.1.2:*:*:*:*:*:*:*\n\n\n\n\ncpe:2.3:a:hitachienergy:650ConnectivityPackage:1.3.0:*:*:*:*:*:*:*\n\n\n\ncpe:2.3:a:hitachienergy:sam600ioConnectivityPackage:1.2.0:*:*:*:*:*:*:*\n\n\ncpe:2.3:a:hitachienergy:sam600ioConnectivityPackage:1.1.0:*:*:*:*:*:*:*\n\n\n\n\ncpe:2.3:a:hitachienergy:sam600ioConnectivityPackage:1.0.0:*:*:*:*:*:*:*\n\n\n\ncpe:2.3:a:hitachienergy:pwc600ConnectivityPackage:1.3.0:*:*:*:*:*:*:*\n\n\ncpe:2.3:a:hitachienergy:pwc600ConnectivityPackage:1.2.0:*:*:*:*:*:*:*\n\n\n\n\ncpe:2.3:a:hitachienergy:pwc600ConnectivityPackage:1.1.2:*:*:*:*:*:*:*\n\n\n\n\ncpe:2.3:a:hitachienergy:pwc600ConnectivityPackage:1.1.1:*:*:*:*:*:*:*\n\n\n\n\ncpe:2.3:a:hitachienergy:pwc600ConnectivityPackage:1.1.0:*:*:*:*:*:*:*\n\n\n\ncpe:2.3:a:hitachienergy:gms600ConnectivityPackage:1.3.1:*:*:*:*:*:*:*\n\n\ncpe:2.3:a:hitachienergy:gms600ConnectivityPackage:1.3.0:*:*:*:*:*:*:*"
        }
      ],
      "source": {
        "advisory": "8DBD000120",
        "discovery": "EXTERNAL"
      },
      "title": "Cleartext Credentials Vulnerability on Hitachi Energy\u2019s Multiple IED Connectivity Packages (IED ConnPacks) and PCM600 Products",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "It is recommended to implement and continuously revise least privileges principles to minimize permissions and\naccesses to PCM600 related resources, included the backup file, PCMI/PCMP file.\u003cbr\u003e\u003cbr\u003e Recommended security\npractices and firewall configurations can help protect a process control network from attacks that originate from\noutside the network. Such practices include that process control systems are physically protected from direct\naccess by unauthorized personnel, have no direct connections to the Internet, and are separated from other\nnetworks by means of a firewall system that has a minimal number of ports exposed, and others that have to be\nevaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or\nreceiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses\nbefore they are connected to a control system. \u003cbr\u003e\u003cbr\u003eAn additional recommendation is to follow the hardening guidelines published by \u201cThe Center for Internet Security\n(CIS)\u201d \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.cisecurity.org/about-us/\"\u003ehttps://www.cisecurity.org/about-us/\u003c/a\u003e to protect the host Operating System.\n\u003cbr\u003e\u003cbr\u003eMore information to deploy PCM600 securely can be found in the following documents:\n1MRS758440, PCM600 Cyber Security Deployment Guideline\n\n\n\n\n\u003cbr\u003e"
            }
          ],
          "value": "It is recommended to implement and continuously revise least privileges principles to minimize permissions and\naccesses to PCM600 related resources, included the backup file, PCMI/PCMP file.\n\n Recommended security\npractices and firewall configurations can help protect a process control network from attacks that originate from\noutside the network. Such practices include that process control systems are physically protected from direct\naccess by unauthorized personnel, have no direct connections to the Internet, and are separated from other\nnetworks by means of a firewall system that has a minimal number of ports exposed, and others that have to be\nevaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or\nreceiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses\nbefore they are connected to a control system. \n\nAn additional recommendation is to follow the hardening guidelines published by \u201cThe Center for Internet Security\n(CIS)\u201d  https://www.cisecurity.org/about-us/  to protect the host Operating System.\n\n\nMore information to deploy PCM600 securely can be found in the following documents:\n1MRS758440, PCM600 Cyber Security Deployment Guideline"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
    "assignerShortName": "Hitachi Energy",
    "cveId": "CVE-2022-2513",
    "datePublished": "2022-11-22T10:30:34.309Z",
    "dateReserved": "2022-07-22T13:30:13.171Z",
    "dateUpdated": "2025-08-27T20:32:51.508Z",
    "requesterUserId": "add9a720-9bad-45a2-bedc-fce6888e4172",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-42066 (GCVE-0-2021-42066)

Vulnerability from cvelistv5 – Published: 2021-12-14 15:44 – Updated: 2024-08-04 03:22
VLAI
Summary
SAP Business One - version 10.0, allows an admin user to view DB password in plain text over the network, which should otherwise be encrypted. For an attacker to discover vulnerable function in-depth application knowledge is required, but once exploited the attacker may be able to completely compromise confidentiality, integrity, and availability of the application.
Severity
No CVSS data available.
CWE
Assigner
sap
References
Impacted products
Vendor Product Version
SAP SE SAP Business One Affected: < 10.0
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T03:22:25.756Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://launchpad.support.sap.com/#/notes/3101299"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://wiki.scn.sap.com/wiki/pages/viewpage.action?pageId=596902035"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SAP Business One",
          "vendor": "SAP SE",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 10.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "SAP Business One - version 10.0, allows an admin user to view DB password in plain text over the network, which should otherwise be encrypted. For an attacker to discover vulnerable function in-depth application knowledge is required, but once exploited the attacker may be able to completely compromise confidentiality, integrity, and availability of the application."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-01-14T19:11:40.000Z",
        "orgId": "e4686d1a-f260-4930-ac4c-2f5c992778dd",
        "shortName": "sap"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://launchpad.support.sap.com/#/notes/3101299"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://wiki.scn.sap.com/wiki/pages/viewpage.action?pageId=596902035"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cna@sap.com",
          "ID": "CVE-2021-42066",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SAP Business One",
                      "version": {
                        "version_data": [
                          {
                            "version_name": "\u003c",
                            "version_value": "10.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "SAP SE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "SAP Business One - version 10.0, allows an admin user to view DB password in plain text over the network, which should otherwise be encrypted. For an attacker to discover vulnerable function in-depth application knowledge is required, but once exploited the attacker may be able to completely compromise confidentiality, integrity, and availability of the application."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": "null",
            "vectorString": "null",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://launchpad.support.sap.com/#/notes/3101299",
              "refsource": "MISC",
              "url": "https://launchpad.support.sap.com/#/notes/3101299"
            },
            {
              "name": "https://wiki.scn.sap.com/wiki/pages/viewpage.action?pageId=596902035",
              "refsource": "MISC",
              "url": "https://wiki.scn.sap.com/wiki/pages/viewpage.action?pageId=596902035"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e4686d1a-f260-4930-ac4c-2f5c992778dd",
    "assignerShortName": "sap",
    "cveId": "CVE-2021-42066",
    "datePublished": "2021-12-14T15:44:11.000Z",
    "dateReserved": "2021-10-07T00:00:00.000Z",
    "dateUpdated": "2024-08-04T03:22:25.756Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-38422 (GCVE-0-2021-38422)

Vulnerability from cvelistv5 – Published: 2021-11-03 19:05 – Updated: 2024-09-16 17:47
VLAI
Title
Delta Electronics DIALink
Summary
Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an attacker to have extensive access to the application directory and escalate privileges.
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
Impacted products
Vendor Product Version
Delta Electronics DIALink Affected: All , ≤ 1.2.4.0 (custom)
Create a notification for this product.
Date Public
2021-10-21 00:00
Credits
Michael Heinzl reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:44:22.224Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DIALink",
          "vendor": "Delta Electronics",
          "versions": [
            {
              "lessThanOrEqual": "1.2.4.0",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Michael Heinzl reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2021-10-21T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an attacker to have extensive access to the application directory and escalate privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312 Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-11-03T19:05:10.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
        }
      ],
      "source": {
        "advisory": "ICSA-21-294-02",
        "discovery": "UNKNOWN"
      },
      "title": "Delta Electronics DIALink",
      "workarounds": [
        {
          "lang": "en",
          "value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2021-10-21T18:29:00.000Z",
          "ID": "CVE-2021-38422",
          "STATE": "PUBLIC",
          "TITLE": "Delta Electronics DIALink"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "DIALink",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "1.2.4.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Delta Electronics"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Michael Heinzl reported these vulnerabilities to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an attacker to have extensive access to the application directory and escalate privileges."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312 Cleartext Storage of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
            }
          ]
        },
        "source": {
          "advisory": "ICSA-21-294-02",
          "discovery": "UNKNOWN"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-38422",
    "datePublished": "2021-11-03T19:05:10.286Z",
    "dateReserved": "2021-08-10T00:00:00.000Z",
    "dateUpdated": "2024-09-16T17:47:43.779Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-36782 (GCVE-0-2021-36782)

Vulnerability from cvelistv5 – Published: 2022-09-07 08:20 – Updated: 2024-09-17 04:14
VLAI
Title
Rancher: Plaintext storage and exposure of credentials in Rancher API and cluster.management.cattle.io object
Summary
A Cleartext Storage of Sensitive Information vulnerability in SUSE Rancher allows authenticated Cluster Owners, Cluster Members, Project Owners, Project Members and User Base to use the Kubernetes API to retrieve plaintext version of sensitive data. This issue affects: SUSE Rancher Rancher versions prior to 2.5.16; Rancher versions prior to 2.6.7.
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
Impacted products
Vendor Product Version
SUSE Rancher Affected: Rancher , < 2.5.16 (custom)
Create a notification for this product.
SUSE Rancher Affected: Rancher , < 2.6.7 (custom)
Create a notification for this product.
Date Public
2022-08-19 00:00
Credits
Florian Struck (from Continum AG) and Marco Stuurman (from Shock Media B.V.)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:01:59.069Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://bugzilla.suse.com/show_bug.cgi?id=1193988"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://github.com/rancher/rancher/security/advisories/GHSA-g7j7-h4q8-8w2f"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Rancher",
          "vendor": "SUSE",
          "versions": [
            {
              "lessThan": "2.5.16",
              "status": "affected",
              "version": "Rancher",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Rancher",
          "vendor": "SUSE",
          "versions": [
            {
              "lessThan": "2.6.7",
              "status": "affected",
              "version": "Rancher",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Florian Struck (from Continum AG) and Marco Stuurman (from Shock Media B.V.)"
        }
      ],
      "datePublic": "2022-08-19T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A Cleartext Storage of Sensitive Information vulnerability in SUSE Rancher allows authenticated Cluster Owners, Cluster Members, Project Owners, Project Members and User Base to use the Kubernetes API to retrieve plaintext version of sensitive data. This issue affects: SUSE Rancher Rancher versions prior to 2.5.16; Rancher versions prior to 2.6.7."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.9,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312: Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-07T08:20:15.000Z",
        "orgId": "404e59f5-483d-4b8a-8e7a-e67604dd8afb",
        "shortName": "suse"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://bugzilla.suse.com/show_bug.cgi?id=1193988"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/rancher/rancher/security/advisories/GHSA-g7j7-h4q8-8w2f"
        }
      ],
      "source": {
        "advisory": "https://bugzilla.suse.com/show_bug.cgi?id=1193988",
        "defect": [
          "1193988"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "Rancher: Plaintext storage and exposure of credentials in Rancher API and cluster.management.cattle.io object",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@suse.com",
          "DATE_PUBLIC": "2022-08-19T00:00:00.000Z",
          "ID": "CVE-2021-36782",
          "STATE": "PUBLIC",
          "TITLE": "Rancher: Plaintext storage and exposure of credentials in Rancher API and cluster.management.cattle.io object"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Rancher",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "Rancher",
                            "version_value": "2.5.16"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Rancher",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "Rancher",
                            "version_value": "2.6.7"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "SUSE"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Florian Struck (from Continum AG) and Marco Stuurman (from Shock Media B.V.)"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A Cleartext Storage of Sensitive Information vulnerability in SUSE Rancher allows authenticated Cluster Owners, Cluster Members, Project Owners, Project Members and User Base to use the Kubernetes API to retrieve plaintext version of sensitive data. This issue affects: SUSE Rancher Rancher versions prior to 2.5.16; Rancher versions prior to 2.6.7."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.9,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312: Cleartext Storage of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://bugzilla.suse.com/show_bug.cgi?id=1193988",
              "refsource": "CONFIRM",
              "url": "https://bugzilla.suse.com/show_bug.cgi?id=1193988"
            },
            {
              "name": "https://github.com/rancher/rancher/security/advisories/GHSA-g7j7-h4q8-8w2f",
              "refsource": "CONFIRM",
              "url": "https://github.com/rancher/rancher/security/advisories/GHSA-g7j7-h4q8-8w2f"
            }
          ]
        },
        "source": {
          "advisory": "https://bugzilla.suse.com/show_bug.cgi?id=1193988",
          "defect": [
            "1193988"
          ],
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "404e59f5-483d-4b8a-8e7a-e67604dd8afb",
    "assignerShortName": "suse",
    "cveId": "CVE-2021-36782",
    "datePublished": "2022-09-07T08:20:16.064Z",
    "dateReserved": "2021-07-19T00:00:00.000Z",
    "dateUpdated": "2024-09-17T04:14:05.504Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-35526 (GCVE-0-2021-35526)

Vulnerability from cvelistv5 – Published: 2021-09-08 15:10 – Updated: 2024-09-16 19:30
VLAI
Title
Storage of Sensitive Information Vulnerability in Hitachi ABB Power Grids System Data Manager – SDM600 Product
Summary
Backup file without encryption vulnerability is found in Hitachi ABB Power Grids System Data Manager – SDM600 allows attacker to gain access to sensitive information. This issue affects: Hitachi ABB Power Grids System Data Manager – SDM600 1.2 versions prior to FP2 HF6 (Build Nr. 1.2.14002.257).
CWE
  • cleartext storage
  • CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
Impacted products
Date Public
2021-08-31 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:40:47.159Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?utm_campaign=\u0026utm_content=2021.08_5051_Cybersecurity%20Advisory%3A\u0026utm_medium=email\u0026utm_source=Eloqua\u0026DocumentID=9AKK107992A4700\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026elqTrackId=ba79ef3d8aec4a4fad6c0cbe06d33d6c\u0026elq=1bda419954724e908db108def16646a5\u0026elqaid=3638\u0026elqat=1\u0026elqCampaignId="
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-250-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "prior to Build Nr. 1.2.14002.257"
          ],
          "product": "System Data Manager \u2013 SDM600",
          "vendor": "Hitachi ABB Power Grids",
          "versions": [
            {
              "lessThan": "FP2 HF6",
              "status": "affected",
              "version": "1.2",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-08-31T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Backup file without encryption vulnerability is found in Hitachi ABB Power Grids System Data Manager \u2013 SDM600 allows attacker to gain access to sensitive information. This issue affects: Hitachi ABB Power Grids System Data Manager \u2013 SDM600 1.2 versions prior to FP2 HF6 (Build Nr. 1.2.14002.257)."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "cleartext storage",
              "lang": "en",
              "type": "text"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312 Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-10-08T16:38:51.000Z",
        "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "shortName": "Hitachi Energy"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://search.abb.com/library/Download.aspx?utm_campaign=\u0026utm_content=2021.08_5051_Cybersecurity%20Advisory%3A\u0026utm_medium=email\u0026utm_source=Eloqua\u0026DocumentID=9AKK107992A4700\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026elqTrackId=ba79ef3d8aec4a4fad6c0cbe06d33d6c\u0026elq=1bda419954724e908db108def16646a5\u0026elqaid=3638\u0026elqat=1\u0026elqCampaignId="
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-250-02"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "The problem is remediated as of the following product version SDM600 version 1.2 FP2 HF6 (Build Nr. 1.2.14002.257). Hitachi ABB Power Grids recommends that customers apply the update at the earliest convenience. After successful upgrade it is recommended to move previously created vulnerable backups to secure place to avoid any nonauthorized access."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Storage of Sensitive Information Vulnerability in Hitachi ABB Power Grids System Data Manager \u2013 SDM600 Product",
      "workarounds": [
        {
          "lang": "en",
          "value": "It is recommended to implement and continuously revise least privileges principles to minimize permissions and accesses to SDM600 related resources. Furthermore, recommended security practices as defined in SDM600 security deployment guideline and firewall configurations can help to protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.\n\nAdditional recommendation is to follow the hardening guidelines published by \u201cThe Center for Internet Security (CIS)\u201d https://www.cisecurity.org/about-us/ to protect the host Operating System."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@hitachi-powergrids.com",
          "DATE_PUBLIC": "2021-08-31T10:00:00.000Z",
          "ID": "CVE-2021-35526",
          "STATE": "PUBLIC",
          "TITLE": "Storage of Sensitive Information Vulnerability in Hitachi ABB Power Grids System Data Manager \u2013 SDM600 Product"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "System Data Manager \u2013 SDM600",
                      "version": {
                        "version_data": [
                          {
                            "platform": "prior to Build Nr. 1.2.14002.257",
                            "version_affected": "\u003c",
                            "version_name": "1.2",
                            "version_value": "FP2 HF6"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Hitachi ABB Power Grids"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Backup file without encryption vulnerability is found in Hitachi ABB Power Grids System Data Manager \u2013 SDM600 allows attacker to gain access to sensitive information. This issue affects: Hitachi ABB Power Grids System Data Manager \u2013 SDM600 1.2 versions prior to FP2 HF6 (Build Nr. 1.2.14002.257)."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "cleartext storage"
                }
              ]
            },
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312 Cleartext Storage of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://search.abb.com/library/Download.aspx?utm_campaign=\u0026utm_content=2021.08_5051_Cybersecurity%20Advisory%3A\u0026utm_medium=email\u0026utm_source=Eloqua\u0026DocumentID=9AKK107992A4700\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026elqTrackId=ba79ef3d8aec4a4fad6c0cbe06d33d6c\u0026elq=1bda419954724e908db108def16646a5\u0026elqaid=3638\u0026elqat=1\u0026elqCampaignId=",
              "refsource": "CONFIRM",
              "url": "https://search.abb.com/library/Download.aspx?utm_campaign=\u0026utm_content=2021.08_5051_Cybersecurity%20Advisory%3A\u0026utm_medium=email\u0026utm_source=Eloqua\u0026DocumentID=9AKK107992A4700\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026elqTrackId=ba79ef3d8aec4a4fad6c0cbe06d33d6c\u0026elq=1bda419954724e908db108def16646a5\u0026elqaid=3638\u0026elqat=1\u0026elqCampaignId="
            },
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-250-02",
              "refsource": "CONFIRM",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-250-02"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "The problem is remediated as of the following product version SDM600 version 1.2 FP2 HF6 (Build Nr. 1.2.14002.257). Hitachi ABB Power Grids recommends that customers apply the update at the earliest convenience. After successful upgrade it is recommended to move previously created vulnerable backups to secure place to avoid any nonauthorized access."
          }
        ],
        "source": {
          "discovery": "INTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "It is recommended to implement and continuously revise least privileges principles to minimize permissions and accesses to SDM600 related resources. Furthermore, recommended security practices as defined in SDM600 security deployment guideline and firewall configurations can help to protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.\n\nAdditional recommendation is to follow the hardening guidelines published by \u201cThe Center for Internet Security (CIS)\u201d https://www.cisecurity.org/about-us/ to protect the host Operating System."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
    "assignerShortName": "Hitachi Energy",
    "cveId": "CVE-2021-35526",
    "datePublished": "2021-09-08T15:10:08.403Z",
    "dateReserved": "2021-06-28T00:00:00.000Z",
    "dateUpdated": "2024-09-16T19:30:41.163Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-35036 (GCVE-0-2021-35036)

Vulnerability from cvelistv5 – Published: 2022-03-01 06:20 – Updated: 2024-08-04 00:33
VLAI
Summary
A cleartext storage of information vulnerability in the Zyxel VMG3625-T50B firmware version V5.50(ABTL.0)b2k could allow an authenticated attacker to obtain sensitive information from the configuration file.
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
Impacted products
Vendor Product Version
Zyxel VMG3625-T50B firmware Affected: V5.50(ABTL.0)b2k
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:33:49.906Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.zyxel.com/global/en/support/security-advisories/zyxel-security-advisory-for-cleartext-storage-of-information-vulnerability"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "VMG3625-T50B firmware",
          "vendor": "Zyxel",
          "versions": [
            {
              "status": "affected",
              "version": "V5.50(ABTL.0)b2k"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A cleartext storage of information vulnerability in the Zyxel VMG3625-T50B firmware version V5.50(ABTL.0)b2k could allow an authenticated attacker to obtain sensitive information from the configuration file."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312: Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-27T13:19:55.000Z",
        "orgId": "96e50032-ad0d-4058-a115-4d2c13821f9f",
        "shortName": "Zyxel"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.zyxel.com/global/en/support/security-advisories/zyxel-security-advisory-for-cleartext-storage-of-information-vulnerability"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@zyxel.com.tw",
          "ID": "CVE-2021-35036",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "VMG3625-T50B firmware",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "V5.50(ABTL.0)b2k"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Zyxel"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A cleartext storage of information vulnerability in the Zyxel VMG3625-T50B firmware version V5.50(ABTL.0)b2k could allow an authenticated attacker to obtain sensitive information from the configuration file."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": "6.5",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312: Cleartext Storage of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.zyxel.com/global/en/support/security-advisories/zyxel-security-advisory-for-cleartext-storage-of-information-vulnerability",
              "refsource": "CONFIRM",
              "url": "https://www.zyxel.com/global/en/support/security-advisories/zyxel-security-advisory-for-cleartext-storage-of-information-vulnerability"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "96e50032-ad0d-4058-a115-4d2c13821f9f",
    "assignerShortName": "Zyxel",
    "cveId": "CVE-2021-35036",
    "datePublished": "2022-03-01T06:20:12.000Z",
    "dateReserved": "2021-06-17T00:00:00.000Z",
    "dateUpdated": "2024-08-04T00:33:49.906Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation
Implementation System Configuration Operation

When storing data in the cloud (e.g., S3 buckets, Azure blobs, Google Cloud Storage, etc.), use the provider's controls to encrypt the data at rest. [REF-1297] [REF-1299] [REF-1301]

Mitigation
Implementation System Configuration Operation

In some systems/environments such as cloud, the use of "double encryption" (at both the software and hardware layer) might be required, and the developer might be solely responsible for both layers, instead of shared responsibility with the administrator of the broader system/environment.

CAPEC-37: Retrieve Embedded Sensitive Data

An attacker examines a target system to find sensitive data that has been embedded within it. This information can reveal confidential contents, such as account numbers or individual keys/credentials that can be used as an intermediate step in a larger attack.