Common Weakness Enumeration

CWE-259

Allowed

Use of Hard-coded Password

Abstraction: Variant · Status: Draft

The product contains a hard-coded password, which it uses for its own inbound authentication or for outbound communication to external components.

315 vulnerabilities reference this CWE, most recent first.

GHSA-GFJP-9255-98GH

Vulnerability from github – Published: 2022-05-24 19:07 – Updated: 2022-05-24 19:07
VLAI
Details

Use of MAC address as an authenticated password in QSAN Storage Manager, XEVO, SANOS allows local attackers to escalate privileges.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2021-32521"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-259",
      "CWE-798"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2021-07-07T14:15:00Z",
    "severity": "HIGH"
  },
  "details": "Use of MAC address as an authenticated password in QSAN Storage Manager, XEVO, SANOS allows local attackers to escalate privileges.",
  "id": "GHSA-gfjp-9255-98gh",
  "modified": "2022-05-24T19:07:02Z",
  "published": "2022-05-24T19:07:02Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2021-32521"
    },
    {
      "type": "WEB",
      "url": "https://www.twcert.org.tw/tw/cp-132-4877-7b696-1.html"
    }
  ],
  "schema_version": "1.4.0",
  "severity": []
}

GHSA-GM88-FXW9-3JVW

Vulnerability from github – Published: 2025-08-24 09:30 – Updated: 2025-08-24 09:30
VLAI
Details

A vulnerability was identified in FNKvision Y215 CCTV Camera 10.194.120.40. Affected by this issue is some unknown functionality of the file /etc/passwd of the component Firmware. Such manipulation leads to hard-coded credentials. Local access is required to approach this attack. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2025-9380"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-259"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2025-08-24T07:15:30Z",
    "severity": "HIGH"
  },
  "details": "A vulnerability was identified in FNKvision Y215 CCTV Camera 10.194.120.40. Affected by this issue is some unknown functionality of the file /etc/passwd of the component Firmware. Such manipulation leads to hard-coded credentials. Local access is required to approach this attack. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.",
  "id": "GHSA-gm88-fxw9-3jvw",
  "modified": "2025-08-24T09:30:19Z",
  "published": "2025-08-24T09:30:19Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2025-9380"
    },
    {
      "type": "WEB",
      "url": "https://vorachat.somsuay.com/blog/Hacking%20CCTV%20FNKvision%20-%20Y215"
    },
    {
      "type": "WEB",
      "url": "https://vorachat.somsuay.com/blog/Hacking%20CCTV%20FNKvision%20-%20Y215/#vulnerability-1-hardcoded-root-credentials-in-multiple-binaries"
    },
    {
      "type": "WEB",
      "url": "https://vuldb.com/?ctiid.321213"
    },
    {
      "type": "WEB",
      "url": "https://vuldb.com/?id.321213"
    },
    {
      "type": "WEB",
      "url": "https://vuldb.com/?submit.629810"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
      "type": "CVSS_V3"
    },
    {
      "score": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
      "type": "CVSS_V4"
    }
  ]
}

GHSA-GPCP-GX8H-767W

Vulnerability from github – Published: 2024-01-08 03:30 – Updated: 2024-01-08 03:30
VLAI
Details

IBM Storage Fusion HCI 2.1.0 through 2.6.1 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 275671.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2023-50948"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-259",
      "CWE-798"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2024-01-08T02:15:13Z",
    "severity": "MODERATE"
  },
  "details": "IBM Storage Fusion HCI 2.1.0 through 2.6.1 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data.  IBM X-Force ID:  275671.",
  "id": "GHSA-gpcp-gx8h-767w",
  "modified": "2024-01-08T03:30:32Z",
  "published": "2024-01-08T03:30:32Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2023-50948"
    },
    {
      "type": "WEB",
      "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/275671"
    },
    {
      "type": "WEB",
      "url": "https://www.ibm.com/support/pages/node/7105509"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
      "type": "CVSS_V3"
    }
  ]
}

GHSA-GWRW-FM59-98G3

Vulnerability from github – Published: 2024-03-21 03:36 – Updated: 2024-03-21 03:36
VLAI
Details

Microsoft Edge for Android (Chromium-based) Information Disclosure Vulnerability

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2024-26196"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-259"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2024-03-21T02:52:16Z",
    "severity": "MODERATE"
  },
  "details": "Microsoft Edge for Android (Chromium-based) Information Disclosure Vulnerability",
  "id": "GHSA-gwrw-fm59-98g3",
  "modified": "2024-03-21T03:36:46Z",
  "published": "2024-03-21T03:36:46Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2024-26196"
    },
    {
      "type": "WEB",
      "url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2024-26196"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
      "type": "CVSS_V3"
    }
  ]
}

GHSA-H38J-6R2Q-95R4

Vulnerability from github – Published: 2026-03-16 15:30 – Updated: 2026-03-16 15:30
VLAI
Details

A weakness has been identified in i-SENS SmartLog App up to 2.6.8 on Android. This affects an unknown function of the component air.SmartLog.android. This manipulation causes hard-coded credentials. The attack can only be executed locally. The exploit has been made available to the public and could be used for attacks. The vendor explains: "The function referenced in the report currently exists in our deployed system. It is related to a developer mode used during the configuration process for Bluetooth pairing between the blood glucose meter and the SmartLog application. This function is intended for configuration purposes related to device integration and testing. (...) [I]n a future application update, we plan to review measures to either remove the developer mode function or restrict access to it."

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2026-4216"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-259"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2026-03-16T14:20:08Z",
    "severity": "MODERATE"
  },
  "details": "A weakness has been identified in i-SENS SmartLog App up to 2.6.8 on Android. This affects an unknown function of the component air.SmartLog.android. This manipulation causes hard-coded credentials. The attack can only be executed locally. The exploit has been made available to the public and could be used for attacks. The vendor explains: \"The function referenced in the report currently exists in our deployed system. It is related to a developer mode used during the configuration process for Bluetooth pairing between the blood glucose meter and the SmartLog application. This function is intended for configuration purposes related to device integration and testing. (...) [I]n a future application update, we plan to review measures to either remove the developer mode function or restrict access to it.\"",
  "id": "GHSA-h38j-6r2q-95r4",
  "modified": "2026-03-16T15:30:46Z",
  "published": "2026-03-16T15:30:45Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2026-4216"
    },
    {
      "type": "WEB",
      "url": "https://vuldb.com/?ctiid.351140"
    },
    {
      "type": "WEB",
      "url": "https://vuldb.com/?id.351140"
    },
    {
      "type": "WEB",
      "url": "https://vuldb.com/?submit.770497"
    },
    {
      "type": "WEB",
      "url": "https://www.notion.so/Developer-Mode-Credential-Exposure-in-air-SmartLog-android-3182de3f97fb80f1abb7e958be2940fa?source=copy_link"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
      "type": "CVSS_V3"
    },
    {
      "score": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
      "type": "CVSS_V4"
    }
  ]
}

GHSA-H39X-RMXF-4P9X

Vulnerability from github – Published: 2025-03-05 06:31 – Updated: 2025-11-03 21:33
VLAI
Details

Vasion Print (formerly PrinterLogic) before Virtual Appliance Host 22.0.1002 Application 20.0.2614 allows Hardcoded Password V-2024-013.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2025-27638"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-259"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2025-03-05T06:15:35Z",
    "severity": "CRITICAL"
  },
  "details": "Vasion Print (formerly PrinterLogic) before Virtual Appliance Host 22.0.1002 Application 20.0.2614 allows Hardcoded Password V-2024-013.",
  "id": "GHSA-h39x-rmxf-4p9x",
  "modified": "2025-11-03T21:33:05Z",
  "published": "2025-03-05T06:31:41Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2025-27638"
    },
    {
      "type": "WEB",
      "url": "https://help.printerlogic.com/saas/Print/Security/Security-Bulletins.htm"
    },
    {
      "type": "WEB",
      "url": "https://pierrekim.github.io/blog/2025-04-08-vasion-printerlogic-83-vulnerabilities.html"
    },
    {
      "type": "WEB",
      "url": "http://seclists.org/fulldisclosure/2025/Apr/18"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
      "type": "CVSS_V3"
    }
  ]
}

GHSA-HC7G-5QRX-9JVJ

Vulnerability from github – Published: 2025-07-14 03:30 – Updated: 2025-07-14 03:30
VLAI
Details

A vulnerability, which was classified as critical, has been found in LB-LINK BL-AC3600 1.0.22. Affected by this issue is some unknown functionality of the file /etc/shadow. The manipulation with the input root:blinkadmin leads to hard-coded credentials. Local access is required to approach this attack. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2025-7564"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-259",
      "CWE-798"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2025-07-14T03:15:24Z",
    "severity": "HIGH"
  },
  "details": "A vulnerability, which was classified as critical, has been found in LB-LINK BL-AC3600 1.0.22. Affected by this issue is some unknown functionality of the file /etc/shadow. The manipulation with the input root:blinkadmin leads to hard-coded credentials. Local access is required to approach this attack. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.",
  "id": "GHSA-hc7g-5qrx-9jvj",
  "modified": "2025-07-14T03:30:33Z",
  "published": "2025-07-14T03:30:33Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2025-7564"
    },
    {
      "type": "WEB",
      "url": "https://github.com/waiwai24/0101/blob/main/CVEs/Blink/Hardcoded_Credentials_in_BL-AC3600_Routers.md"
    },
    {
      "type": "WEB",
      "url": "https://github.com/waiwai24/0101/blob/main/CVEs/Blink/Hardcoded_Credentials_in_BL-AC3600_Routers.md#poc"
    },
    {
      "type": "WEB",
      "url": "https://vuldb.com/?ctiid.316262"
    },
    {
      "type": "WEB",
      "url": "https://vuldb.com/?id.316262"
    },
    {
      "type": "WEB",
      "url": "https://vuldb.com/?submit.605630"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
      "type": "CVSS_V3"
    },
    {
      "score": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
      "type": "CVSS_V4"
    }
  ]
}

GHSA-HGG3-GV88-82VV

Vulnerability from github – Published: 2024-06-14 06:34 – Updated: 2024-07-04 06:35
VLAI
Details

Toshiba printers contain hardcoded credentials. As for the affected products/models/versions, see the reference URL.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2024-27164"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-259"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2024-06-14T04:15:33Z",
    "severity": "HIGH"
  },
  "details": "Toshiba printers contain hardcoded credentials. As for the affected products/models/versions, see the reference URL.",
  "id": "GHSA-hgg3-gv88-82vv",
  "modified": "2024-07-04T06:35:04Z",
  "published": "2024-06-14T06:34:46Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2024-27164"
    },
    {
      "type": "WEB",
      "url": "https://jvn.jp/en/vu/JVNVU97136265/index.html"
    },
    {
      "type": "WEB",
      "url": "https://www.toshibatec.com/information/20240531_01.html"
    },
    {
      "type": "WEB",
      "url": "https://www.toshibatec.com/information/pdf/information20240531_01.pdf"
    },
    {
      "type": "WEB",
      "url": "http://seclists.org/fulldisclosure/2024/Jul/1"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
      "type": "CVSS_V3"
    }
  ]
}

GHSA-HP2W-73JH-3X82

Vulnerability from github – Published: 2024-08-06 18:30 – Updated: 2024-08-06 18:30
VLAI
Details

D-Link DIR-300 REVA FIRMWARE v1.06B05_WW contains hardcoded credentials in the Telnet service.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2024-41616"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-259",
      "CWE-798"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2024-08-06T16:15:49Z",
    "severity": "HIGH"
  },
  "details": "D-Link DIR-300 REVA FIRMWARE v1.06B05_WW contains hardcoded credentials in the Telnet service.",
  "id": "GHSA-hp2w-73jh-3x82",
  "modified": "2024-08-06T18:30:56Z",
  "published": "2024-08-06T18:30:56Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2024-41616"
    },
    {
      "type": "WEB",
      "url": "https://github.com/LYaoBoL/IOTsec/blob/main/D-Link/DIR300/CVE-2024-41616"
    },
    {
      "type": "WEB",
      "url": "https://github.com/LYaoBoL/IOTsec/blob/main/D-Link/DIR300/D-Link300.md"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
      "type": "CVSS_V3"
    }
  ]
}

GHSA-HPVM-W4R5-3G24

Vulnerability from github – Published: 2026-01-29 21:30 – Updated: 2026-01-29 21:30
VLAI
Details

A vulnerability was found in Tenda AX12 Pro V2 16.03.49.24_cn. Affected by this issue is some unknown functionality of the component Telnet Service. Performing a manipulation results in hard-coded credentials. The attack is possible to be carried out remotely. A high degree of complexity is needed for the attack. The exploitation is known to be difficult. The exploit has been made public and could be used.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2026-1610"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-259"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2026-01-29T19:16:19Z",
    "severity": "HIGH"
  },
  "details": "A vulnerability was found in Tenda AX12 Pro V2 16.03.49.24_cn. Affected by this issue is some unknown functionality of the component Telnet Service. Performing a manipulation results in hard-coded credentials. The attack is possible to be carried out remotely. A high degree of complexity is needed for the attack. The exploitation is known to be difficult. The exploit has been made public and could be used.",
  "id": "GHSA-hpvm-w4r5-3g24",
  "modified": "2026-01-29T21:30:30Z",
  "published": "2026-01-29T21:30:30Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2026-1610"
    },
    {
      "type": "WEB",
      "url": "https://github.com/QIU-DIE/CVE/issues/49"
    },
    {
      "type": "WEB",
      "url": "https://vuldb.com/?ctiid.343378"
    },
    {
      "type": "WEB",
      "url": "https://vuldb.com/?id.343378"
    },
    {
      "type": "WEB",
      "url": "https://vuldb.com/?submit.740766"
    },
    {
      "type": "WEB",
      "url": "https://www.tenda.com.cn"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
      "type": "CVSS_V3"
    },
    {
      "score": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
      "type": "CVSS_V4"
    }
  ]
}

Mitigation
Architecture and Design

For outbound authentication: store passwords outside of the code in a strongly-protected, encrypted configuration file or database that is protected from access by all outsiders, including other local users on the same system. Properly protect the key (CWE-320). If you cannot use encryption to protect the file, then make sure that the permissions are as restrictive as possible.

Mitigation
Architecture and Design

For inbound authentication: Rather than hard-code a default username and password for first time logins, utilize a "first login" mode that requires the user to enter a unique strong password.

Mitigation
Architecture and Design

Perform access control checks and limit which entities can access the feature that requires the hard-coded password. For example, a feature might only be enabled through the system console instead of through a network connection.

Mitigation
Architecture and Design
  • For inbound authentication: apply strong one-way hashes to your passwords and store those hashes in a configuration file or database with appropriate access control. That way, theft of the file/database still requires the attacker to try to crack the password. When receiving an incoming password during authentication, take the hash of the password and compare it to the hash that you have saved.
  • Use randomly assigned salts for each separate hash that you generate. This increases the amount of computation that an attacker needs to conduct a brute-force attack, possibly limiting the effectiveness of the rainbow table method.
Mitigation
Architecture and Design

For front-end to back-end connections: Three solutions are possible, although none are complete.

No CAPEC attack patterns related to this CWE.