CVE-2024-1628 (GCVE-0-2024-1628)

Vulnerability from cvelistv5 – Published: 2024-05-14 16:04 – Updated: 2024-08-01 18:48
VLAI
Title
OS command injection vulnerabilities in GE HealthCare ultrasound devices
Summary
OS command injection vulnerabilities in GE HealthCare ultrasound devices
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-16 16:10 UTC
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version CPE status
GE HealthCare Venue Affected: R1
Affected: R2
Affected: R3 , ≤ R3.3 (custom)
Affected: R4 , ≤ R4.3 (custom)
guessed Create a notification for this product.
GE HealthCare Venue Go Affected: R2
Affected: R3 , ≤ R3.3 (custom)
Affected: R4 , ≤ R4.3 (custom)
guessed Create a notification for this product.
GE HealthCare Venue Fit Affected: R3 , ≤ R3.3 (custom)
Affected: R4 , ≤ R4.3 (custom)
guessed Create a notification for this product.
GE HealthCare LOGIQ e Affected: R7 , ≤ R9.1.4 (custom)
Affected: R8 , ≤ R10.1.3 (custom)
Affected: R9 , ≤ R11.0.3 (custom)
guessed Create a notification for this product.
GE HealthCare LOGIQ He Affected: 0 , ≤ R9.3.1 (custom)
guessed Create a notification for this product.
GE HealthCare Vivid E Affected: E95 , < 206 (custom)
Affected: E90 , < 206 (custom)
Affected: E80 , < 206 (custom)
guessed Create a notification for this product.
GE HealthCare Vivid S Affected: 70N , < 206 (custom)
Affected: 60N , < 206 (custom)
guessed Create a notification for this product.
GE HealthCare Vivid T Affected: T8 , < 206 (custom)
Affected: T9 , < 206 (custom)
guessed Create a notification for this product.
GE HealthCare Vivid iq Affected: 0 , < 206 (custom)
guessed Create a notification for this product.
GE HealthCare Voluson Expert 16 Affected: 0
Affected: BT24 , < Ext1 (custom)
guessed Create a notification for this product.
GE HealthCare Voluson Expert 18 Affected: 0
Affected: BT24 , < Ext1 (custom)
guessed Create a notification for this product.
GE HealthCare Voluson Expert 22 Affected: 0
Affected: BT24 , < Ext1 (custom)
guessed Create a notification for this product.
GE HealthCare Voluson SWIFT Affected: 0
Affected: BT24
guessed Create a notification for this product.
GE HealthCare Invenia ABUS 2.0 Affected: 0 , ≤ 2.2.7 (custom)
guessed Create a notification for this product.
GE HealthCare LOGIQ E10 Affected: 0 , < R3.2.0 (custom)
guessed Create a notification for this product.
GE HealthCare LOGIQ E10s Affected: 0 , < R3.2.0 (custom)
guessed Create a notification for this product.
GE HealthCare LOGIQ Fortis Affected: 0 , < R3.2.0 (custom)
guessed Create a notification for this product.
ge_healthcare venue Affected: multiple versions
    cpe:2.3:a:ge_healthcare:venue:*:*:*:*:*:*:*:*
Create a notification for this product.
ge_healthcare vivid Affected: multiple versions
    cpe:2.3:a:ge_healthcare:vivid:*:*:*:*:*:*:*:*
Create a notification for this product.
ge_healthcare voluson Affected: multiple versions
    cpe:2.3:a:ge_healthcare:voluson:*:*:*:*:*:*:*:*
Create a notification for this product.
ge_healthcare logiq Affected: multiple versions
    cpe:2.3:a:ge_healthcare:logiq:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:ge_healthcare:venue:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "venue",
            "vendor": "ge_healthcare",
            "versions": [
              {
                "status": "affected",
                "version": "multiple versions"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:ge_healthcare:vivid:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "vivid",
            "vendor": "ge_healthcare",
            "versions": [
              {
                "status": "affected",
                "version": "multiple versions"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:ge_healthcare:voluson:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "voluson",
            "vendor": "ge_healthcare",
            "versions": [
              {
                "status": "affected",
                "version": "multiple versions"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:ge_healthcare:logiq:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "logiq",
            "vendor": "ge_healthcare",
            "versions": [
              {
                "status": "affected",
                "version": "multiple versions"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-1628",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-16T16:10:00.517201Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T18:01:30.939Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T18:48:21.580Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://securityupdate.gehealthcare.com/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Venue",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "status": "affected",
              "version": "R1"
            },
            {
              "status": "affected",
              "version": "R2"
            },
            {
              "lessThanOrEqual": "R3.3",
              "status": "affected",
              "version": "R3",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "R4.3",
              "status": "affected",
              "version": "R4",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Venue Go",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "status": "affected",
              "version": "R2"
            },
            {
              "lessThanOrEqual": "R3.3",
              "status": "affected",
              "version": "R3",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "R4.3",
              "status": "affected",
              "version": "R4",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Venue Fit",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "lessThanOrEqual": "R3.3",
              "status": "affected",
              "version": "R3",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "R4.3",
              "status": "affected",
              "version": "R4",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "LOGIQ e",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "lessThanOrEqual": "R9.1.4",
              "status": "affected",
              "version": "R7",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "R10.1.3",
              "status": "affected",
              "version": "R8",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "R11.0.3",
              "status": "affected",
              "version": "R9",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "LOGIQ He",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "lessThanOrEqual": "R9.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Vivid E",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "lessThan": "206",
              "status": "affected",
              "version": "E95",
              "versionType": "custom"
            },
            {
              "lessThan": "206",
              "status": "affected",
              "version": "E90",
              "versionType": "custom"
            },
            {
              "lessThan": "206",
              "status": "affected",
              "version": "E80",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Vivid S",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "lessThan": "206",
              "status": "affected",
              "version": "70N",
              "versionType": "custom"
            },
            {
              "lessThan": "206",
              "status": "affected",
              "version": "60N",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Vivid T",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "lessThan": "206",
              "status": "affected",
              "version": "T8",
              "versionType": "custom"
            },
            {
              "lessThan": "206",
              "status": "affected",
              "version": "T9",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Vivid iq",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "lessThan": "206",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Voluson Expert 16",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "status": "affected",
              "version": "0"
            },
            {
              "lessThan": "Ext1",
              "status": "affected",
              "version": "BT24",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Voluson Expert 18",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "status": "affected",
              "version": "0"
            },
            {
              "lessThan": "Ext1",
              "status": "affected",
              "version": "BT24",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Voluson Expert 22",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "status": "affected",
              "version": "0"
            },
            {
              "lessThan": "Ext1",
              "status": "affected",
              "version": "BT24",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Voluson SWIFT",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "status": "affected",
              "version": "0"
            },
            {
              "status": "affected",
              "version": "BT24"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Invenia ABUS 2.0",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "lessThanOrEqual": "2.2.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "LOGIQ E10",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "lessThan": "R3.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "LOGIQ E10s",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "lessThan": "R3.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "LOGIQ Fortis",
          "vendor": "GE HealthCare",
          "versions": [
            {
              "lessThan": "R3.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "OS command injection vulnerabilities in GE HealthCare ultrasound devices"
            }
          ],
          "value": "OS command injection vulnerabilities in GE HealthCare ultrasound devices"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-6",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-6 Argument Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-14T16:04:57.780Z",
        "orgId": "171caf72-b841-4e04-a68e-93493aff2b94",
        "shortName": "GEHC"
      },
      "references": [
        {
          "url": "https://securityupdate.gehealthcare.com/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "OS command injection vulnerabilities in GE HealthCare ultrasound devices",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "171caf72-b841-4e04-a68e-93493aff2b94",
    "assignerShortName": "GEHC",
    "cveId": "CVE-2024-1628",
    "datePublished": "2024-05-14T16:04:57.780Z",
    "dateReserved": "2024-02-19T15:23:20.113Z",
    "dateUpdated": "2024-08-01T18:48:21.580Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-1628",
      "date": "2026-09-28",
      "epss": "0.00836",
      "percentile": "0.56046"
    },
    "fkie_nvd": {
      "descriptions": [
        {
          "lang": "en",
          "value": "OS command injection vulnerabilities in GE HealthCare ultrasound devices"
        },
        {
          "lang": "es",
          "value": "Vulnerabilidades de inyecci\u00f3n de comandos del sistema operativo en dispositivos de ultrasonido GE HealthCare"
        }
      ],
      "id": "CVE-2024-1628",
      "lastModified": "2024-11-21T08:50:57.333",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 8.4,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.5,
            "impactScore": 5.9,
            "source": "171caf72-b841-4e04-a68e-93493aff2b94",
            "type": "Secondary"
          }
        ]
      },
      "published": "2024-05-14T16:16:00.470",
      "references": [
        {
          "source": "171caf72-b841-4e04-a68e-93493aff2b94",
          "url": "https://securityupdate.gehealthcare.com/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://securityupdate.gehealthcare.com/"
        }
      ],
      "sourceIdentifier": "171caf72-b841-4e04-a68e-93493aff2b94",
      "vulnStatus": "Awaiting Analysis",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-78"
            }
          ],
          "source": "171caf72-b841-4e04-a68e-93493aff2b94",
          "type": "Secondary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "Venue",
                "vendor": "GE HealthCare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "R1"
                  },
                  {
                    "status": "affected",
                    "version": "R2"
                  },
                  {
                    "lessThanOrEqual": "R3.3",
                    "status": "affected",
                    "version": "R3",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "R4.3",
                    "status": "affected",
                    "version": "R4",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "Venue Go",
                "vendor": "GE HealthCare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "R2"
                  },
                  {
                    "lessThanOrEqual": "R3.3",
                    "status": "affected",
                    "version": "R3",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "R4.3",
                    "status": "affected",
                    "version": "R4",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "Venue Fit",
                "vendor": "GE HealthCare",
                "versions": [
                  {
                    "lessThanOrEqual": "R3.3",
                    "status": "affected",
                    "version": "R3",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "R4.3",
                    "status": "affected",
                    "version": "R4",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "LOGIQ e",
                "vendor": "GE HealthCare",
                "versions": [
                  {
                    "lessThanOrEqual": "R9.1.4",
                    "status": "affected",
                    "version": "R7",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "R10.1.3",
                    "status": "affected",
                    "version": "R8",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "R11.0.3",
                    "status": "affected",
                    "version": "R9",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "LOGIQ He",
                "vendor": "GE HealthCare",
                "versions": [
                  {
                    "lessThanOrEqual": "R9.3.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "Vivid E",
                "vendor": "GE HealthCare",
                "versions": [
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "E95",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "E90",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "E80",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "Vivid S",
                "vendor": "GE HealthCare",
                "versions": [
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "70N",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "60N",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "Vivid T",
                "vendor": "GE HealthCare",
                "versions": [
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "T8",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "T9",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "Vivid iq",
                "vendor": "GE HealthCare",
                "versions": [
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "Voluson Expert 16",
                "vendor": "GE HealthCare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "0"
                  },
                  {
                    "lessThan": "Ext1",
                    "status": "affected",
                    "version": "BT24",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "Voluson Expert 18",
                "vendor": "GE HealthCare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "0"
                  },
                  {
                    "lessThan": "Ext1",
                    "status": "affected",
                    "version": "BT24",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "Voluson Expert 22",
                "vendor": "GE HealthCare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "0"
                  },
                  {
                    "lessThan": "Ext1",
                    "status": "affected",
                    "version": "BT24",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "Voluson SWIFT",
                "vendor": "GE HealthCare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "0"
                  },
                  {
                    "status": "affected",
                    "version": "BT24"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "Invenia ABUS 2.0",
                "vendor": "GE HealthCare",
                "versions": [
                  {
                    "lessThanOrEqual": "2.2.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "LOGIQ E10",
                "vendor": "GE HealthCare",
                "versions": [
                  {
                    "lessThan": "R3.2.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "LOGIQ E10s",
                "vendor": "GE HealthCare",
                "versions": [
                  {
                    "lessThan": "R3.2.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "LOGIQ Fortis",
                "vendor": "GE HealthCare",
                "versions": [
                  {
                    "lessThan": "R3.2.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "171caf72-b841-4e04-a68e-93493aff2b94"
          },
          {
            "affectedData": [
              {
                "cpes": [
                  "cpe:2.3:a:ge_healthcare:venue:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "venue",
                "vendor": "ge_healthcare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "multiple versions"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:ge_healthcare:vivid:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vivid",
                "vendor": "ge_healthcare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "multiple versions"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:ge_healthcare:voluson:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "voluson",
                "vendor": "ge_healthcare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "multiple versions"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:ge_healthcare:logiq:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "logiq",
                "vendor": "ge_healthcare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "multiple versions"
                  }
                ]
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "OS command injection vulnerabilities in GE HealthCare ultrasound devices"
          },
          {
            "lang": "es",
            "value": "Vulnerabilidades de inyecci\u00f3n de comandos del sistema operativo en dispositivos de ultrasonido GE HealthCare"
          }
        ],
        "id": "CVE-2024-1628",
        "lastModified": "2026-06-17T07:04:39.297",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.5,
              "impactScore": 5.9,
              "source": "171caf72-b841-4e04-a68e-93493aff2b94",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2024-1628",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-16T16:10:00.517201Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-05-14T16:16:00.470",
        "references": [
          {
            "source": "171caf72-b841-4e04-a68e-93493aff2b94",
            "url": "https://securityupdate.gehealthcare.com/"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "url": "https://securityupdate.gehealthcare.com/"
          }
        ],
        "sourceIdentifier": "171caf72-b841-4e04-a68e-93493aff2b94",
        "vulnStatus": "Deferred",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-78"
              }
            ],
            "source": "171caf72-b841-4e04-a68e-93493aff2b94",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-28T20:03:58+00:00",
      "cve": "CVE-2024-1628",
      "id": "CVE-2024-1628",
      "initial_release_date": "2024-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "OS command injection vulnerabilities in GE HealthCare ultrasound devices",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-1628.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T18:48:21.580Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://securityupdate.gehealthcare.com/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:ge_healthcare:venue:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "venue",
                "vendor": "ge_healthcare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "multiple versions"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:ge_healthcare:vivid:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vivid",
                "vendor": "ge_healthcare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "multiple versions"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:ge_healthcare:voluson:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "voluson",
                "vendor": "ge_healthcare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "multiple versions"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:ge_healthcare:logiq:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "logiq",
                "vendor": "ge_healthcare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "multiple versions"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-1628",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-16T16:10:00.517201Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-05-16T16:13:24.505Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Venue",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "status": "affected",
                  "version": "R1"
                },
                {
                  "status": "affected",
                  "version": "R2"
                },
                {
                  "lessThanOrEqual": "R3.3",
                  "status": "affected",
                  "version": "R3",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "R4.3",
                  "status": "affected",
                  "version": "R4",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Venue Go",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "status": "affected",
                  "version": "R2"
                },
                {
                  "lessThanOrEqual": "R3.3",
                  "status": "affected",
                  "version": "R3",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "R4.3",
                  "status": "affected",
                  "version": "R4",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Venue Fit",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThanOrEqual": "R3.3",
                  "status": "affected",
                  "version": "R3",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "R4.3",
                  "status": "affected",
                  "version": "R4",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "LOGIQ e",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThanOrEqual": "R9.1.4",
                  "status": "affected",
                  "version": "R7",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "R10.1.3",
                  "status": "affected",
                  "version": "R8",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "R11.0.3",
                  "status": "affected",
                  "version": "R9",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "LOGIQ He",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThanOrEqual": "R9.3.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Vivid E",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "E95",
                  "versionType": "custom"
                },
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "E90",
                  "versionType": "custom"
                },
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "E80",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Vivid S",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "70N",
                  "versionType": "custom"
                },
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "60N",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Vivid T",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "T8",
                  "versionType": "custom"
                },
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "T9",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Vivid iq",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Voluson Expert 16",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "status": "affected",
                  "version": "0"
                },
                {
                  "lessThan": "Ext1",
                  "status": "affected",
                  "version": "BT24",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Voluson Expert 18",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "status": "affected",
                  "version": "0"
                },
                {
                  "lessThan": "Ext1",
                  "status": "affected",
                  "version": "BT24",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Voluson Expert 22",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "status": "affected",
                  "version": "0"
                },
                {
                  "lessThan": "Ext1",
                  "status": "affected",
                  "version": "BT24",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Voluson SWIFT",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "status": "affected",
                  "version": "0"
                },
                {
                  "status": "affected",
                  "version": "BT24"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Invenia ABUS 2.0",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThanOrEqual": "2.2.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "LOGIQ E10",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "R3.2.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "LOGIQ E10s",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "R3.2.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "LOGIQ Fortis",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "R3.2.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "OS command injection vulnerabilities in GE HealthCare ultrasound devices"
                }
              ],
              "value": "OS command injection vulnerabilities in GE HealthCare ultrasound devices"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-6",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-6 Argument Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-14T16:04:57.780Z",
            "orgId": "171caf72-b841-4e04-a68e-93493aff2b94",
            "shortName": "GEHC"
          },
          "references": [
            {
              "url": "https://securityupdate.gehealthcare.com/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "OS command injection vulnerabilities in GE HealthCare ultrasound devices",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "171caf72-b841-4e04-a68e-93493aff2b94",
        "assignerShortName": "GEHC",
        "cveId": "CVE-2024-1628",
        "datePublished": "2024-05-14T16:04:57.780Z",
        "dateReserved": "2024-02-19T15:23:20.113Z",
        "dateUpdated": "2024-08-01T18:48:21.580Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…