CWE-489

Active Debug Code

The product is released with debugging code still enabled or active.

CVE-2024-30219 (GCVE-0-2024-30219)
Vulnerability from cvelistv5
Published
2024-04-15 10:42
Modified
2025-08-27 21:02
CWE
Summary
Active debug code vulnerability exists in PLANEX COMMUNICATIONS wireless LAN routers. If a logged-in user who knows how to use the debug function accesses the device's management page, an unintended operation may be performed. Note that MZK-MF300N is no longer supported, therefore the update for this product is not provided.
References
Impacted products
Vendor Product Version
PLANEX COMMUNICATIONS INC. MZK-MF300N Version: all firmware versions
Create a notification for this product.
   PLANEX COMMUNICATIONS INC. MZK-MF300HP2 Version: firmware versions 1.18 and earlier
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:planex:mzk-mf300n_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "mzk-mf300n_firmware",
            "vendor": "planex",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-30219",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-27T02:15:27.805566Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-27T21:02:07.280Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:25:03.416Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU91975826/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "MZK-MF300N",
          "vendor": "PLANEX COMMUNICATIONS INC.",
          "versions": [
            {
              "status": "affected",
              "version": "all firmware versions"
            }
          ]
        },
        {
          "product": "MZK-MF300HP2",
          "vendor": "PLANEX COMMUNICATIONS INC.",
          "versions": [
            {
              "status": "affected",
              "version": "firmware versions 1.18 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Active debug code vulnerability exists in PLANEX COMMUNICATIONS wireless LAN routers. If a logged-in user who knows how to use the debug function accesses the device\u0027s management page, an unintended operation may be performed. Note that MZK-MF300N is no longer supported, therefore the update for this product is not provided."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-489",
              "description": "Active debug code",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-26T07:21:48.696Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://jvn.jp/en/vu/JVNVU91975826/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2024-30219",
    "datePublished": "2024-04-15T10:42:30.673Z",
    "dateReserved": "2024-03-26T06:29:22.984Z",
    "dateUpdated": "2025-08-27T21:02:07.280Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-53648 (GCVE-0-2024-53648)
Vulnerability from cvelistv5
Published
2025-02-11 10:28
Modified
2025-08-12 11:16
CWE
Summary
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.90), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions < V9.90), SIPROTEC 5 6MU85 (CP300) (All versions < V9.90), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions < V10.0), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V9.90), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V9.90), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V9.90), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V9.90), SIPROTEC 5 7SJ81 (CP100) (All versions), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP100) (All versions), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V9.90), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V9.90), SIPROTEC 5 7SK82 (CP100) (All versions), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V9.90), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V9.90), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V9.90), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V9.90), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions < V9.90), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions < V9.90), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions < V9.90), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions < V9.90), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.90). Affected devices do not properly limit access to a development shell accessible over a physical interface. This could allow an unauthenticated attacker with physical access to the device to execute arbitrary commands on the device.
Impacted products
Vendor Product Version
Siemens SIPROTEC 5 6MD84 (CP300) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 6MD85 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 6MD85 (CP300) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 6MD86 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 6MD86 (CP300) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 6MD89 (CP300) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 6MU85 (CP300) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 7KE85 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7KE85 (CP300) Version: 0   < V10.0
Create a notification for this product.
   Siemens SIPROTEC 5 7SA82 (CP100) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SA82 (CP150) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 7SA86 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SA86 (CP300) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 7SA87 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SA87 (CP300) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 7SD82 (CP100) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SD82 (CP150) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 7SD86 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SD86 (CP300) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 7SD87 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SD87 (CP300) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 7SJ81 (CP100) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SJ81 (CP150) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 7SJ82 (CP100) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SJ82 (CP150) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 7SJ85 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SJ85 (CP300) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 7SJ86 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SJ86 (CP300) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 7SK82 (CP100) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SK82 (CP150) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 7SK85 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SK85 (CP300) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 7SL82 (CP100) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SL82 (CP150) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 7SL86 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SL86 (CP300) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 7SL87 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SL87 (CP300) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 7SS85 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7SS85 (CP300) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 7ST85 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7ST85 (CP300) Version: 0   < V10.0
Create a notification for this product.
   Siemens SIPROTEC 5 7ST86 (CP300) Version: 0   < V10.0
Create a notification for this product.
   Siemens SIPROTEC 5 7SX82 (CP150) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 7SX85 (CP300) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 7SY82 (CP150) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 7UM85 (CP300) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 7UT82 (CP100) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7UT82 (CP150) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 7UT85 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7UT85 (CP300) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 7UT86 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7UT86 (CP300) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 7UT87 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7UT87 (CP300) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 7VE85 (CP300) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 7VK87 (CP200) Version: 0   < *
Create a notification for this product.
   Siemens SIPROTEC 5 7VK87 (CP300) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 7VU85 (CP300) Version: 0   < V9.90
Create a notification for this product.
   Siemens SIPROTEC 5 Compact 7SX800 (CP050) Version: 0   < V9.90
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-53648",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-11T14:35:44.427665Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-11T14:35:58.855Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MD84 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MD85 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MD85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MD86 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MD86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MD89 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 6MU85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7KE85 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7KE85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SA82 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SA82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SA86 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SA86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SA87 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SA87 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SD82 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SD82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SD86 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SD86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SD87 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SD87 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ81 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ81 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ82 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ85 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ86 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SJ86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SK82 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SK82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SK85 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SK85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SL82 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SL82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SL86 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SL86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SL87 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SL87 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SS85 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SS85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7ST85 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7ST85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7ST86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SX82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SX85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7SY82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UM85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT82 (CP100)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT82 (CP150)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT85 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT86 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT86 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT87 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7UT87 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7VE85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7VK87 (CP200)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7VK87 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 7VU85 (CP300)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPROTEC 5 Compact 7SX800 (CP050)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.90",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions \u003c V9.90), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions \u003c V9.90), SIPROTEC 5 6MD89 (CP300) (All versions \u003c V9.90), SIPROTEC 5 6MU85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions \u003c V10.0), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SJ81 (CP100) (All versions), SIPROTEC 5 7SJ81 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SJ82 (CP100) (All versions), SIPROTEC 5 7SJ82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SK82 (CP100) (All versions), SIPROTEC 5 7SK82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions \u003c V10.0), SIPROTEC 5 7ST86 (CP300) (All versions \u003c V10.0), SIPROTEC 5 7SX82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SX85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7SY82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7UM85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7VE85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions \u003c V9.90), SIPROTEC 5 7VU85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 Compact 7SX800 (CP050) (All versions \u003c V9.90). Affected devices do not properly limit access to a development shell accessible over a physical interface. This could allow an unauthenticated attacker with physical access to the device to execute arbitrary commands on the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-489",
              "description": "CWE-489: Active Debug Code",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-12T11:16:50.056Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-687955.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-53648",
    "datePublished": "2025-02-11T10:28:52.039Z",
    "dateReserved": "2024-11-21T13:26:39.692Z",
    "dateUpdated": "2025-08-12T11:16:50.056Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-21472 (GCVE-0-2025-21472)
Vulnerability from cvelistv5
Published
2025-08-06 07:25
Modified
2025-08-06 19:26
CWE
Summary
Information disclosure while capturing logs as eSE debug messages are logged.
Impacted products
Vendor Product Version
Qualcomm, Inc. Snapdragon Version: FastConnect 6900
Version: FastConnect 7800
Version: QCA9367
Version: QCA9377
Version: QCS8550
Version: SA8530P
Version: SA8540P
Version: SA9000P
Version: Snapdragon 8 Gen 1 Mobile Platform
Version: WCD9380
Version: WSA8830
Version: WSA8835
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-21472",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-06T19:26:33.422422Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-06T19:26:42.457Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Snapdragon Auto",
            "Snapdragon Industrial IOT",
            "Snapdragon Mobile"
          ],
          "product": "Snapdragon",
          "vendor": "Qualcomm, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "FastConnect 6900"
            },
            {
              "status": "affected",
              "version": "FastConnect 7800"
            },
            {
              "status": "affected",
              "version": "QCA9367"
            },
            {
              "status": "affected",
              "version": "QCA9377"
            },
            {
              "status": "affected",
              "version": "QCS8550"
            },
            {
              "status": "affected",
              "version": "SA8530P"
            },
            {
              "status": "affected",
              "version": "SA8540P"
            },
            {
              "status": "affected",
              "version": "SA9000P"
            },
            {
              "status": "affected",
              "version": "Snapdragon 8 Gen 1 Mobile Platform"
            },
            {
              "status": "affected",
              "version": "WCD9380"
            },
            {
              "status": "affected",
              "version": "WSA8830"
            },
            {
              "status": "affected",
              "version": "WSA8835"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Information disclosure while capturing logs as eSE debug messages are logged."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-489",
              "description": "CWE-489 Leftover Debug Code",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-06T07:25:56.503Z",
        "orgId": "2cfc7d3e-20d3-47ac-8db7-1b7285aff15f",
        "shortName": "qualcomm"
      },
      "references": [
        {
          "url": "https://docs.qualcomm.com/product/publicresources/securitybulletin/august-2025-bulletin.html"
        }
      ],
      "title": "Leftover Debug Code in Secure Element"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2cfc7d3e-20d3-47ac-8db7-1b7285aff15f",
    "assignerShortName": "qualcomm",
    "cveId": "CVE-2025-21472",
    "datePublished": "2025-08-06T07:25:56.503Z",
    "dateReserved": "2024-12-18T09:50:08.928Z",
    "dateUpdated": "2025-08-06T19:26:42.457Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-7705 (GCVE-0-2025-7705)
Vulnerability from cvelistv5
Published
2025-07-22 11:49
Modified
2025-07-22 13:57
CWE
Summary
: Active Debug Code vulnerability in ABB Switch Actuator 4 DU-83330, ABB Switch actuator, door/light 4 DU -83330-500.This issue affects Switch Actuator 4 DU-83330: All Versions; Switch actuator, door/light 4 DU -83330-500: All Versions.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-7705",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-22T13:55:25.610400Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-22T13:57:30.620Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Switch Actuator 4 DU-83330",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Switch actuator, door/light 4 DU -83330-500",
          "vendor": "ABB",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": ": Active Debug Code vulnerability in ABB Switch Actuator 4 DU-83330, ABB Switch actuator, door/light 4 DU -83330-500.\u003cp\u003eThis issue affects Switch Actuator 4 DU-83330: All Versions; Switch actuator, door/light 4 DU -83330-500: All Versions.\u003c/p\u003e"
            }
          ],
          "value": ": Active Debug Code vulnerability in ABB Switch Actuator 4 DU-83330, ABB Switch actuator, door/light 4 DU -83330-500.This issue affects Switch Actuator 4 DU-83330: All Versions; Switch actuator, door/light 4 DU -83330-500: All Versions."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "PHYSICAL",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-489",
              "description": "CWE-489: Active Debug Code",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-22T12:02:25.322Z",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108471A4556\u0026LanguageCode=en\u0026DocumentPartId=pdf\u0026Action=Launch\u0026_gl=1*1sgofnl*_gcl_au*MjA0NTI4OTE1Mi4xNzUzMTgxNTA2*_ga*MTIxMTUxMzg5MS4xNzUzMTgxNTA3*_ga_46ZFBRSZNM*czE3NTMxODE1MDckbzEkZzEkdDE3NTMxODE2MDIkajYwJGwwJGgw"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Authentication bypass due to compatibility mode enabled by default",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2025-7705",
    "datePublished": "2025-07-22T11:49:00.964Z",
    "dateReserved": "2025-07-16T11:31:40.651Z",
    "dateUpdated": "2025-07-22T13:57:30.620Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation

Phases: Build and Compilation, Distribution

Description:

  • Remove debug code before deploying the application.
CAPEC-121: Exploit Non-Production Interfaces

An adversary exploits a sample, demonstration, test, or debug interface that is unintentionally enabled on a production system, with the goal of gleaning information or leveraging functionality that would otherwise be unavailable.

CAPEC-661: Root/Jailbreak Detection Evasion via Debugging

An adversary inserts a debugger into the program entry point of a mobile application to modify the application binary, with the goal of evading Root/Jailbreak detection. Mobile device users often Root/Jailbreak their devices in order to gain administrative control over the mobile operating system and/or to install third-party mobile applications that are not provided by authorized application stores (e.g. Google Play Store and Apple App Store). Rooting/Jailbreaking a mobile device also provides users with access to system debuggers and disassemblers, which can be leveraged to exploit applications by dumping the application's memory at runtime in order to remove or bypass signature verification methods. This further allows the adversary to evade Root/Jailbreak detection mechanisms, which can result in execution of administrative commands, obtaining confidential data, impersonating legitimate users of the application, and more.

Back to CWE stats page