CWE-286

Incorrect User Management

The product does not properly manage a user within its environment.

CVE-2025-53190 (GCVE-0-2025-53190)
Vulnerability from cvelistv5

This CVE ID has been rejected or withdrawn by its CVE Numbering Authority.

Show details on NVD website


{
  "containers": {
    "cna": {
      "providerMetadata": {
        "dateUpdated": "2025-08-21T10:28:07.479Z",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "rejectedReasons": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "This CVE ID has been rejected or withdrawn by its CVE Numbering Authority."
            }
          ],
          "value": "This CVE ID has been rejected or withdrawn by its CVE Numbering Authority."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2025-53190",
    "datePublished": "2025-08-11T18:28:56.939Z",
    "dateRejected": "2025-08-21T10:28:07.479Z",
    "dateReserved": "2025-06-27T10:01:27.161Z",
    "dateUpdated": "2025-08-21T10:28:07.479Z",
    "state": "REJECTED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-7972 (GCVE-0-2025-7972)
Vulnerability from cvelistv5
Published
2025-08-14 14:47
Modified
2025-08-14 15:08
CWE
  • CWE-286 - Incorrect User Management
Summary
A security issue exists within the FactoryTalk Linx Network Browser. By modifying the process.env.NODE_ENV to ‘development’, the attacker can disable FTSP token validation. This bypass allows access to create, update, and delete FTLinx drivers.
Impacted products
Vendor Product Version
Rockwell Automation FactoryTalk® Linx Version: All prior to 6.50
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-7972",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-14T15:06:45.964707Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-14T15:08:22.952Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FactoryTalk\u00ae Linx",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "All prior to 6.50"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA security issue exists within the FactoryTalk Linx Network Browser. By modifying the process.env.NODE_ENV to \u2018development\u2019, the attacker can disable FTSP token validation. This bypass allows access to create, update, and delete FTLinx drivers. \u003c/span\u003e"
            }
          ],
          "value": "A security issue exists within the FactoryTalk Linx Network Browser. By modifying the process.env.NODE_ENV to \u2018development\u2019, the attacker can disable FTSP token validation. This bypass allows access to create, update, and delete FTLinx drivers."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-286",
              "description": "CWE-286: Incorrect User Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-14T14:54:29.154Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1735.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade to version 6.50 or later."
            }
          ],
          "value": "Upgrade to version 6.50 or later."
        }
      ],
      "source": {
        "advisory": "SD1735",
        "discovery": "INTERNAL"
      },
      "title": "Rockwell Automation FactoryTalk\u00ae Linx Network Browser Security Bypass Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-7972",
    "datePublished": "2025-08-14T14:47:46.316Z",
    "dateReserved": "2025-07-21T19:25:20.271Z",
    "dateUpdated": "2025-08-14T15:08:22.952Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

No mitigation information available for this CWE.

No CAPEC attack patterns related to this CWE.

Back to CWE stats page