CWE-286
Incorrect User Management
The product does not properly manage a user within its environment.
CVE-2025-53190 (GCVE-0-2025-53190)
Vulnerability from cvelistv5
This CVE ID has been rejected or withdrawn by its CVE Numbering Authority.
Show details on NVD website{ "containers": { "cna": { "providerMetadata": { "dateUpdated": "2025-08-21T10:28:07.479Z", "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "shortName": "ABB" }, "rejectedReasons": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "This CVE ID has been rejected or withdrawn by its CVE Numbering Authority." } ], "value": "This CVE ID has been rejected or withdrawn by its CVE Numbering Authority." } ], "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "assignerShortName": "ABB", "cveId": "CVE-2025-53190", "datePublished": "2025-08-11T18:28:56.939Z", "dateRejected": "2025-08-21T10:28:07.479Z", "dateReserved": "2025-06-27T10:01:27.161Z", "dateUpdated": "2025-08-21T10:28:07.479Z", "state": "REJECTED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-7972 (GCVE-0-2025-7972)
Vulnerability from cvelistv5
Published
2025-08-14 14:47
Modified
2025-08-14 15:08
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-286 - Incorrect User Management
Summary
A security issue exists within the FactoryTalk Linx Network Browser. By modifying the process.env.NODE_ENV to ‘development’, the attacker can disable FTSP token validation. This bypass allows access to create, update, and delete FTLinx drivers.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Rockwell Automation | FactoryTalk® Linx |
Version: All prior to 6.50 |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-7972", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-08-14T15:06:45.964707Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-08-14T15:08:22.952Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "FactoryTalk\u00ae Linx", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "All prior to 6.50" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA security issue exists within the FactoryTalk Linx Network Browser. By modifying the process.env.NODE_ENV to \u2018development\u2019, the attacker can disable FTSP token validation. This bypass allows access to create, update, and delete FTLinx drivers. \u003c/span\u003e" } ], "value": "A security issue exists within the FactoryTalk Linx Network Browser. By modifying the process.env.NODE_ENV to \u2018development\u2019, the attacker can disable FTSP token validation. This bypass allows access to create, update, and delete FTLinx drivers." } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "LOCAL", "baseScore": 8.4, "baseSeverity": "HIGH", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "HIGH", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "HIGH", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:H/SA:H", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "NONE", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-286", "description": "CWE-286: Incorrect User Management", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-08-14T14:54:29.154Z", "orgId": "b73dd486-f505-4403-b634-40b078b177f0", "shortName": "Rockwell" }, "references": [ { "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1735.html" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Upgrade to version 6.50 or later." } ], "value": "Upgrade to version 6.50 or later." } ], "source": { "advisory": "SD1735", "discovery": "INTERNAL" }, "title": "Rockwell Automation FactoryTalk\u00ae Linx Network Browser Security Bypass Vulnerability", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0", "assignerShortName": "Rockwell", "cveId": "CVE-2025-7972", "datePublished": "2025-08-14T14:47:46.316Z", "dateReserved": "2025-07-21T19:25:20.271Z", "dateUpdated": "2025-08-14T15:08:22.952Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
No mitigation information available for this CWE.