CVE-2020-7545 (GCVE-0-2020-7545)
Vulnerability from cvelistv5
Published
2020-12-01 14:44
Modified
2024-08-04 09:33
Severity ?
CWE
  • CWE-284 - :Improper Access Control
Summary
A CWE-284:Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow for arbitrary code execution on the server when an authorized user access an affected webpage.
Impacted products
Vendor Product Version
n/a EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) Version: EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:33:19.761Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-284:Improper Access Control vulnerability exists in EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information) that could allow for arbitrary code execution on the server when an authorized user access an affected webpage."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284:Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-12-01T14:44:10",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2020-7545",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-284:Improper Access Control vulnerability exists in EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information) that could allow for arbitrary code execution on the server when an authorized user access an affected webpage."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284:Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/",
              "refsource": "MISC",
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2020-7545",
    "datePublished": "2020-12-01T14:44:10",
    "dateReserved": "2020-01-21T00:00:00",
    "dateUpdated": "2024-08-04T09:33:19.761Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2020-7545\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2020-12-01T15:15:12.297\",\"lastModified\":\"2024-11-21T05:37:21.233\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-284:Improper Access Control vulnerability exists in EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information) that could allow for arbitrary code execution on the server when an authorized user access an affected webpage.\"},{\"lang\":\"es\",\"value\":\"Una CWE-284: Se presenta una vulnerabilidad Control de Acceso Inapropiado en el Software EcoStruxure\u00aa y SmartStruxure\u00aa Power Monitoring and SCADA (v\u00e9ase la notificaci\u00f3n de seguridad para la informaci\u00f3n de la versi\u00f3n) que podr\u00eda permitir una ejecuci\u00f3n de c\u00f3digo arbitraria en el servidor cuando un usuario autorizado accede a una p\u00e1gina web afectada\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:P/A:P\",\"baseScore\":6.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_energy_expert:2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CDF7DFC6-6F41-491B-A703-6AB0143FE5B1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:7.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6819EA7A-C803-480F-98DF-44DA144FE488\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:8.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"66E928C4-87C8-4BD6-9131-B7D558330CBA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:9.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0BEB4F4B-0B22-47CA-B173-C06C1A925348\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:power_manager:1.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2FC0093C-00CE-43A8-80EC-0509992E637B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:power_manager:1.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CE9A1DF0-42B8-4123-8276-1D4BED156034\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:power_manager:1.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"54A54A8D-40F5-4E75-A524-B81E487DB274\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:powerscada_expert_with_advanced_reporting_and_dashboards:8.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3CC2CF9D-8D0C-4FD3-94A2-34A63E297B81\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:powerscada_operation_with_advanced_reporting_and_dashboards:9.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DC8F406C-868A-443C-8842-6CFFFF17C236\"}]}]}],\"references\":[{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2020-287-04/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2020-287-04/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…