Vulnerabilites related to netgear - wac104
Vulnerability from fkie_nvd
Published
2022-03-17 13:15
Modified
2024-11-21 06:30
Summary
A vulnerability is in the 'BRS_top.html' page of the Netgear W104, version WAC104-V1.0.4.13, which can allow a remote attacker to access this page without any authentication. When processed, it exposes firmware version information for the device.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:wac104_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1224F2C1-E4AE-4A21-B45D-1F1BE32AB318",
              "versionEndIncluding": "1.0.4.13",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:wac104:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E4AB65E-0FC3-4B35-B7D6-BD99356E92CE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r7450_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7797134A-94C1-4D06-A940-AE3B783FEBBE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r7450:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6DA5420D-DD64-4A9C-9B5F-784F0ED2B464",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AB4A1B8C-BE12-47FE-88EF-5DC0C5B24769",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r6900:v2:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E8EB69B-6619-47B6-A073-D0B840D4EB0B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8BA136F2-E4FF-468C-B0F8-BE45DD6F78EA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BA80DF41-ECB3-4C63-B960-32D868207F74",
              "versionEndIncluding": "1.1.0.34_1.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B131B5C8-CB7F-433B-BA32-F05CE0E92A66",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability is in the \u0027BRS_top.html\u0027 page of the Netgear W104, version WAC104-V1.0.4.13, which can allow a remote attacker to access this page without any authentication. When processed, it exposes firmware version information for the device."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad en la p\u00e1gina \"BRS_top.html\" del Netgear W104, versi\u00f3n WAC104-V1.0.4.13, que puede permitir a un atacante remoto acceder a esta p\u00e1gina sin ninguna autenticaci\u00f3n. Cuando es procesado, expone la informaci\u00f3n de la versi\u00f3n del firmware del dispositivo"
    }
  ],
  "id": "CVE-2021-44261",
  "lastModified": "2024-11-21T06:30:40.947",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 1.4,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-03-17T13:15:07.550",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/zer0yu/CVE_Request/blob/master/netgear/Netgear_W104_unauthorized_access_vulnerability_first.md"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.netgear.com/about/security/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/zer0yu/CVE_Request/blob/master/netgear/Netgear_W104_unauthorized_access_vulnerability_first.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.netgear.com/about/security/"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2020-12-30 00:15
Modified
2024-11-21 05:28
Summary
NETGEAR WAC104 devices before 1.0.4.13 are affected by a buffer overflow by an authenticated user.
Impacted products
Vendor Product Version
netgear wac104_firmware *
netgear wac104 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:wac104_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5E22E09-672D-4234-A67D-4153558EFBBC",
              "versionEndExcluding": "1.0.4.13",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:wac104:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E4AB65E-0FC3-4B35-B7D6-BD99356E92CE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "NETGEAR WAC104 devices before 1.0.4.13 are affected by a buffer overflow by an authenticated user."
    },
    {
      "lang": "es",
      "value": "Los dispositivos NETGEAR WAC104 versiones anteriores a 1.0.4.13, est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un usuario autenticado."
    }
  ],
  "id": "CVE-2020-35788",
  "lastModified": "2024-11-21T05:28:06.053",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.2,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 5.1,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.6,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.0,
        "impactScore": 6.0,
        "source": "cve@mitre.org",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-12-30T00:15:13.597",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000062719/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-WAC104-PSV-2020-0319"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000062719/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-WAC104-PSV-2020-0319"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-120"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-08-11 00:17
Modified
2024-11-21 06:17
Summary
NETGEAR WAC104 devices before 1.0.4.15 are affected by incorrect configuration of security settings.
Impacted products
Vendor Product Version
netgear wac104_firmware *
netgear wac104 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:wac104_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6628E198-C04B-4756-938D-CA9825BFCF27",
              "versionEndExcluding": "1.0.4.15",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:wac104:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E4AB65E-0FC3-4B35-B7D6-BD99356E92CE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "NETGEAR WAC104 devices before 1.0.4.15 are affected by incorrect configuration of security settings."
    },
    {
      "lang": "es",
      "value": "Los dispositivos NETGEAR WAC104 versiones anteriores a 1.0.4.15, est\u00e1n afectados por una configuraci\u00f3n incorrecta de los ajustes de seguridad"
    }
  ],
  "id": "CVE-2021-38532",
  "lastModified": "2024-11-21T06:17:21.587",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.9,
        "impactScore": 5.9,
        "source": "cve@mitre.org",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-08-11T00:17:12.687",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000063787/Security-Advisory-for-Security-Misconfiguration-on-WAC104-PSV-2021-0124"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000063787/Security-Advisory-for-Security-Misconfiguration-on-WAC104-PSV-2021-0124"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-06-30 15:15
Modified
2024-11-21 06:12
Summary
NETGEAR WAC104 devices before 1.0.4.15 are affected by an authentication bypass vulnerability in /usr/sbin/mini_httpd, allowing an unauthenticated attacker to invoke any action by adding the &currentsetting.htm substring to the HTTP query, a related issue to CVE-2020-27866. This directly allows the attacker to change the web UI password, and eventually to enable debug mode (telnetd) and gain a shell on the device as the admin limited-user account (however, escalation to root is simple because of weak permissions on the /etc/ directory).
Impacted products
Vendor Product Version
netgear wac104_firmware *
netgear wac104 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:wac104_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6628E198-C04B-4756-938D-CA9825BFCF27",
              "versionEndExcluding": "1.0.4.15",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:wac104:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E4AB65E-0FC3-4B35-B7D6-BD99356E92CE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "NETGEAR WAC104 devices before 1.0.4.15 are affected by an authentication bypass vulnerability in /usr/sbin/mini_httpd, allowing an unauthenticated attacker to invoke any action by adding the \u0026currentsetting.htm substring to the HTTP query, a related issue to CVE-2020-27866. This directly allows the attacker to change the web UI password, and eventually to enable debug mode (telnetd) and gain a shell on the device as the admin limited-user account (however, escalation to root is simple because of weak permissions on the /etc/ directory)."
    },
    {
      "lang": "es",
      "value": "Los dispositivos NETGEAR WAC104 versiones anteriores a 1.0.4.15 est\u00e1n afectados por una vulnerabilidad de omisi\u00f3n de autenticaci\u00f3n en /usr/sbin/mini_httpd, que permite a un atacante no autenticado invocar cualquier acci\u00f3n a\u00f1adiendo la subcadena \u0026amp;currentsetting.htm a la consulta HTTP, un problema relacionado con CVE-2020-27866. Esto permite directamente al atacante cambiar la contrase\u00f1a de la interfaz web, y eventualmente habilitar el modo de depuraci\u00f3n (telnetd) y obtener un shell en el dispositivo como la cuenta de usuario limitado admin (sin embargo, la escalada a root es sencilla debido a los permisos d\u00e9biles en el directorio /etc/)"
    }
  ],
  "id": "CVE-2021-35973",
  "lastModified": "2024-11-21T06:12:52.027",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "cve@mitre.org",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-06-30T15:15:10.607",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://gynvael.coldwind.pl/?lang=en\u0026id=736"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000063785/Security-Advisory-for-Authentication-Bypass-on-WAC104-PSV-2021-0075"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://gynvael.coldwind.pl/?lang=en\u0026id=736"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000063785/Security-Advisory-for-Authentication-Bypass-on-WAC104-PSV-2021-0075"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-697"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-03-17 13:15
Modified
2024-11-21 06:30
Summary
A vulnerability is in the 'MNU_top.htm' page of the Netgear W104, version WAC104-V1.0.4.13, which can allow a remote attacker to access this page without any authentication. When processed, it exposes some key information for the device.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:mbr1517_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C8FE85F1-96A8-4F29-8663-20D550C5D1B4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:mbr1517:v2:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD50FF16-1B9E-4A22-91FD-A0B7F77A857D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:wnce3001_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B58E9604-8E56-420D-8E3B-B60AB8E98C0B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:wnce3001:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F7483D3-2CA5-4C8B-A878-A296F2CD8DBF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:wac104_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1224F2C1-E4AE-4A21-B45D-1F1BE32AB318",
              "versionEndIncluding": "1.0.4.13",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:wac104:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E4AB65E-0FC3-4B35-B7D6-BD99356E92CE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability is in the \u0027MNU_top.htm\u0027 page of the Netgear W104, version WAC104-V1.0.4.13, which can allow a remote attacker to access this page without any authentication. When processed, it exposes some key information for the device."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad en la p\u00e1gina \"MNU_top.htm\" del Netgear W104, versi\u00f3n WAC104-V1.0.4.13, que puede permitir a un atacante remoto acceder a esta p\u00e1gina sin ninguna autenticaci\u00f3n. Cuando es procesado, expone determinada informaci\u00f3n clave para el dispositivo"
    }
  ],
  "id": "CVE-2021-44262",
  "lastModified": "2024-11-21T06:30:41.140",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-03-17T13:15:07.593",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/zer0yu/CVE_Request/blob/master/netgear/Netgear_W104_unauthorized_access_vulnerability_second.md"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.netgear.com/about/security/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/zer0yu/CVE_Request/blob/master/netgear/Netgear_W104_unauthorized_access_vulnerability_second.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.netgear.com/about/security/"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2021-35973 (GCVE-0-2021-35973)
Vulnerability from cvelistv5
Published
2021-06-30 14:41
Modified
2024-08-04 00:47
Severity ?
CWE
  • n/a
Summary
NETGEAR WAC104 devices before 1.0.4.15 are affected by an authentication bypass vulnerability in /usr/sbin/mini_httpd, allowing an unauthenticated attacker to invoke any action by adding the &currentsetting.htm substring to the HTTP query, a related issue to CVE-2020-27866. This directly allows the attacker to change the web UI password, and eventually to enable debug mode (telnetd) and gain a shell on the device as the admin limited-user account (however, escalation to root is simple because of weak permissions on the /etc/ directory).
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:47:43.087Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://gynvael.coldwind.pl/?lang=en\u0026id=736"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000063785/Security-Advisory-for-Authentication-Bypass-on-WAC104-PSV-2021-0075"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "NETGEAR WAC104 devices before 1.0.4.15 are affected by an authentication bypass vulnerability in /usr/sbin/mini_httpd, allowing an unauthenticated attacker to invoke any action by adding the \u0026currentsetting.htm substring to the HTTP query, a related issue to CVE-2020-27866. This directly allows the attacker to change the web UI password, and eventually to enable debug mode (telnetd) and gain a shell on the device as the admin limited-user account (however, escalation to root is simple because of weak permissions on the /etc/ directory)."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:N/A:H/C:H/I:H/PR:N/S:U/UI:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-30T14:41:04",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://gynvael.coldwind.pl/?lang=en\u0026id=736"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.netgear.com/000063785/Security-Advisory-for-Authentication-Bypass-on-WAC104-PSV-2021-0075"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-35973",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "NETGEAR WAC104 devices before 1.0.4.15 are affected by an authentication bypass vulnerability in /usr/sbin/mini_httpd, allowing an unauthenticated attacker to invoke any action by adding the \u0026currentsetting.htm substring to the HTTP query, a related issue to CVE-2020-27866. This directly allows the attacker to change the web UI password, and eventually to enable debug mode (telnetd) and gain a shell on the device as the admin limited-user account (however, escalation to root is simple because of weak permissions on the /etc/ directory)."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:N/A:H/C:H/I:H/PR:N/S:U/UI:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://gynvael.coldwind.pl/?lang=en\u0026id=736",
              "refsource": "MISC",
              "url": "https://gynvael.coldwind.pl/?lang=en\u0026id=736"
            },
            {
              "name": "https://kb.netgear.com/000063785/Security-Advisory-for-Authentication-Bypass-on-WAC104-PSV-2021-0075",
              "refsource": "MISC",
              "url": "https://kb.netgear.com/000063785/Security-Advisory-for-Authentication-Bypass-on-WAC104-PSV-2021-0075"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-35973",
    "datePublished": "2021-06-30T14:41:04",
    "dateReserved": "2021-06-30T00:00:00",
    "dateUpdated": "2024-08-04T00:47:43.087Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-44262 (GCVE-0-2021-44262)
Vulnerability from cvelistv5
Published
2022-03-17 12:21
Modified
2024-08-04 04:17
Severity ?
CWE
  • n/a
Summary
A vulnerability is in the 'MNU_top.htm' page of the Netgear W104, version WAC104-V1.0.4.13, which can allow a remote attacker to access this page without any authentication. When processed, it exposes some key information for the device.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:17:24.876Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.netgear.com/about/security/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/zer0yu/CVE_Request/blob/master/netgear/Netgear_W104_unauthorized_access_vulnerability_second.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability is in the \u0027MNU_top.htm\u0027 page of the Netgear W104, version WAC104-V1.0.4.13, which can allow a remote attacker to access this page without any authentication. When processed, it exposes some key information for the device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-17T12:21:44",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.netgear.com/about/security/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/zer0yu/CVE_Request/blob/master/netgear/Netgear_W104_unauthorized_access_vulnerability_second.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-44262",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability is in the \u0027MNU_top.htm\u0027 page of the Netgear W104, version WAC104-V1.0.4.13, which can allow a remote attacker to access this page without any authentication. When processed, it exposes some key information for the device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.netgear.com/about/security/",
              "refsource": "MISC",
              "url": "https://www.netgear.com/about/security/"
            },
            {
              "name": "https://github.com/zer0yu/CVE_Request/blob/master/netgear/Netgear_W104_unauthorized_access_vulnerability_second.md",
              "refsource": "MISC",
              "url": "https://github.com/zer0yu/CVE_Request/blob/master/netgear/Netgear_W104_unauthorized_access_vulnerability_second.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-44262",
    "datePublished": "2022-03-17T12:21:44",
    "dateReserved": "2021-11-29T00:00:00",
    "dateUpdated": "2024-08-04T04:17:24.876Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-38532 (GCVE-0-2021-38532)
Vulnerability from cvelistv5
Published
2021-08-10 23:59
Modified
2024-08-04 01:44
CWE
  • n/a
Summary
NETGEAR WAC104 devices before 1.0.4.15 are affected by incorrect configuration of security settings.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:44:23.468Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000063787/Security-Advisory-for-Security-Misconfiguration-on-WAC104-PSV-2021-0124"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "NETGEAR WAC104 devices before 1.0.4.15 are affected by incorrect configuration of security settings."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-08-10T23:59:55",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.netgear.com/000063787/Security-Advisory-for-Security-Misconfiguration-on-WAC104-PSV-2021-0124"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-38532",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "NETGEAR WAC104 devices before 1.0.4.15 are affected by incorrect configuration of security settings."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "availabilityImpact": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000063787/Security-Advisory-for-Security-Misconfiguration-on-WAC104-PSV-2021-0124",
              "refsource": "MISC",
              "url": "https://kb.netgear.com/000063787/Security-Advisory-for-Security-Misconfiguration-on-WAC104-PSV-2021-0124"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-38532",
    "datePublished": "2021-08-10T23:59:55",
    "dateReserved": "2021-08-10T00:00:00",
    "dateUpdated": "2024-08-04T01:44:23.468Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-35788 (GCVE-0-2020-35788)
Vulnerability from cvelistv5
Published
2020-12-29 23:40
Modified
2024-08-04 17:09
CWE
  • n/a
Summary
NETGEAR WAC104 devices before 1.0.4.13 are affected by a buffer overflow by an authenticated user.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T17:09:15.200Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000062719/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-WAC104-PSV-2020-0319"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "NETGEAR WAC104 devices before 1.0.4.13 are affected by a buffer overflow by an authenticated user."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:H/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-12-29T23:40:13",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.netgear.com/000062719/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-WAC104-PSV-2020-0319"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-35788",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "NETGEAR WAC104 devices before 1.0.4.13 are affected by a buffer overflow by an authenticated user."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT",
            "availabilityImpact": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:H/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000062719/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-WAC104-PSV-2020-0319",
              "refsource": "MISC",
              "url": "https://kb.netgear.com/000062719/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-WAC104-PSV-2020-0319"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-35788",
    "datePublished": "2020-12-29T23:40:13",
    "dateReserved": "2020-12-29T00:00:00",
    "dateUpdated": "2024-08-04T17:09:15.200Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-44261 (GCVE-0-2021-44261)
Vulnerability from cvelistv5
Published
2022-03-17 12:24
Modified
2024-08-04 04:17
Severity ?
CWE
  • n/a
Summary
A vulnerability is in the 'BRS_top.html' page of the Netgear W104, version WAC104-V1.0.4.13, which can allow a remote attacker to access this page without any authentication. When processed, it exposes firmware version information for the device.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:17:24.935Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.netgear.com/about/security/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/zer0yu/CVE_Request/blob/master/netgear/Netgear_W104_unauthorized_access_vulnerability_first.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability is in the \u0027BRS_top.html\u0027 page of the Netgear W104, version WAC104-V1.0.4.13, which can allow a remote attacker to access this page without any authentication. When processed, it exposes firmware version information for the device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-17T12:24:14",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.netgear.com/about/security/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/zer0yu/CVE_Request/blob/master/netgear/Netgear_W104_unauthorized_access_vulnerability_first.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-44261",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability is in the \u0027BRS_top.html\u0027 page of the Netgear W104, version WAC104-V1.0.4.13, which can allow a remote attacker to access this page without any authentication. When processed, it exposes firmware version information for the device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.netgear.com/about/security/",
              "refsource": "MISC",
              "url": "https://www.netgear.com/about/security/"
            },
            {
              "name": "https://github.com/zer0yu/CVE_Request/blob/master/netgear/Netgear_W104_unauthorized_access_vulnerability_first.md",
              "refsource": "MISC",
              "url": "https://github.com/zer0yu/CVE_Request/blob/master/netgear/Netgear_W104_unauthorized_access_vulnerability_first.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-44261",
    "datePublished": "2022-03-17T12:24:14",
    "dateReserved": "2021-11-29T00:00:00",
    "dateUpdated": "2024-08-04T04:17:24.935Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

var-202106-1098
Vulnerability from variot

NETGEAR WAC104 devices before 1.0.4.15 are affected by an authentication bypass vulnerability in /usr/sbin/mini_httpd, allowing an unauthenticated attacker to invoke any action by adding the &currentsetting.htm substring to the HTTP query, a related issue to CVE-2020-27866. This directly allows the attacker to change the web UI password, and eventually to enable debug mode (telnetd) and gain a shell on the device as the admin limited-user account (however, escalation to root is simple because of weak permissions on the /etc/ directory). NETGEAR WAC104 There is an authentication vulnerability in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. NETGEAR WAC104 is a wireless access point (AP) from Netgear

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202106-1098",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "wac104",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "netgear",
        "version": "1.0.4.15"
      },
      {
        "model": "wac104",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": null
      },
      {
        "model": "wac104",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": "wac104  firmware  1.0.4.15"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-06701"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008865"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-35973"
      }
    ]
  },
  "cve": "CVE-2021-35973",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2021-35973",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-06701",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2021-35973",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "OTHER",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2021-008865",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2021-35973",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "cve@mitre.org",
            "id": "CVE-2021-35973",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2021-35973",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-06701",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202106-1999",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULMON",
            "id": "CVE-2021-35973",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-06701"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-35973"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008865"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202106-1999"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-35973"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-35973"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "NETGEAR WAC104 devices before 1.0.4.15 are affected by an authentication bypass vulnerability in /usr/sbin/mini_httpd, allowing an unauthenticated attacker to invoke any action by adding the \u0026currentsetting.htm substring to the HTTP query, a related issue to CVE-2020-27866. This directly allows the attacker to change the web UI password, and eventually to enable debug mode (telnetd) and gain a shell on the device as the admin limited-user account (however, escalation to root is simple because of weak permissions on the /etc/ directory). NETGEAR WAC104 There is an authentication vulnerability in the device.Information is obtained, information is tampered with, and service is disrupted  (DoS) It may be put into a state. NETGEAR WAC104 is a wireless access point (AP) from Netgear",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-35973"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008865"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-06701"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-35973"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-35973",
        "trust": 3.9
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008865",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-06701",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202106-1999",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-35973",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-06701"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-35973"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008865"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202106-1999"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-35973"
      }
    ]
  },
  "id": "VAR-202106-1098",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-06701"
      }
    ],
    "trust": 1.14285717
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-06701"
      }
    ]
  },
  "last_update_date": "2024-08-14T14:11:21.989000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top\u00a0Page",
        "trust": 0.8,
        "url": "https://www.netgear.com/"
      },
      {
        "title": "Patch for NETGEAR WAC104 Authentication Bypass Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/316111"
      },
      {
        "title": "Netgear NETGEAR WAC104 Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=155610"
      },
      {
        "title": "SecBooks\nSecBooks\u76ee\u5f55",
        "trust": 0.1,
        "url": "https://github.com/SexyBeast233/SecBooks "
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-06701"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-35973"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008865"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202106-1999"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-697",
        "trust": 1.0
      },
      {
        "problemtype": "Improper authentication (CWE-287) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008865"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-35973"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://gynvael.coldwind.pl/?lang=en\u0026id=736"
      },
      {
        "trust": 1.7,
        "url": "https://kb.netgear.com/000063785/security-advisory-for-authentication-bypass-on-wac104-psv-2021-0075"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-35973"
      },
      {
        "trust": 0.6,
        "url": "https://gynvael.coldwind.pl/?lang=en\u0026id;=736"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/697.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/sexybeast233/secbooks"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-06701"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-35973"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008865"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202106-1999"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-35973"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-06701"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-35973"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008865"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202106-1999"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-35973"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-01-25T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-06701"
      },
      {
        "date": "2021-06-30T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-35973"
      },
      {
        "date": "2022-03-29T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-008865"
      },
      {
        "date": "2021-06-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202106-1999"
      },
      {
        "date": "2021-06-30T15:15:10.607000",
        "db": "NVD",
        "id": "CVE-2021-35973"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-01-25T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-06701"
      },
      {
        "date": "2022-07-12T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-35973"
      },
      {
        "date": "2022-03-29T09:13:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-008865"
      },
      {
        "date": "2022-07-14T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202106-1999"
      },
      {
        "date": "2022-07-12T17:42:04.277000",
        "db": "NVD",
        "id": "CVE-2021-35973"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202106-1999"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "NETGEAR\u00a0WAC104\u00a0 Authentication vulnerability in device",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008865"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "authorization issue",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202106-1999"
      }
    ],
    "trust": 0.6
  }
}

var-202203-0653
Vulnerability from variot

A vulnerability is in the 'MNU_top.htm' page of the Netgear W104, version WAC104-V1.0.4.13, which can allow a remote attacker to access this page without any authentication. When processed, it exposes some key information for the device. of netgear mbr1517 firmware, wnce3001 firmware, WAC104 Firmware has a lack of authentication vulnerability for critical functionality.Information may be obtained. Netgear W104 is a wireless access point from Netgear Corporation of the United States

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202203-0653",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "mbr1517",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "netgear",
        "version": "*"
      },
      {
        "model": "wnce3001",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "netgear",
        "version": "*"
      },
      {
        "model": "wac104",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "netgear",
        "version": "1.0.4.13"
      },
      {
        "model": "wac104",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": null
      },
      {
        "model": "wnce3001",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": null
      },
      {
        "model": "mbr1517",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": null
      },
      {
        "model": "wac104",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "netgear",
        "version": "\u003c=1.0.4.13"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-22306"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018882"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-44262"
      }
    ]
  },
  "cve": "CVE-2021-44262",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2021-44262",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-22306",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2021-44262",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2021-44262",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2021-44262",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2021-44262",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-22306",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202203-1571",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-22306"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018882"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1571"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-44262"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability is in the \u0027MNU_top.htm\u0027 page of the Netgear W104, version WAC104-V1.0.4.13, which can allow a remote attacker to access this page without any authentication. When processed, it exposes some key information for the device. of netgear mbr1517 firmware, wnce3001 firmware, WAC104 Firmware has a lack of authentication vulnerability for critical functionality.Information may be obtained. Netgear W104 is a wireless access point from Netgear Corporation of the United States",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-44262"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018882"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-22306"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-44262",
        "trust": 3.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018882",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-22306",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1571",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-22306"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018882"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1571"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-44262"
      }
    ]
  },
  "id": "VAR-202203-0653",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-22306"
      }
    ],
    "trust": 1.2037465233333333
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-22306"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:47:29.675000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-306",
        "trust": 1.0
      },
      {
        "problemtype": "Lack of authentication for critical features (CWE-306) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018882"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-44262"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/zer0yu/cve_request/blob/master/netgear/netgear_w104_unauthorized_access_vulnerability_second.md"
      },
      {
        "trust": 2.4,
        "url": "https://www.netgear.com/about/security/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-44262"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2021-44262/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018882"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1571"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-44262"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-22306"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018882"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1571"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-44262"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-03-24T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-22306"
      },
      {
        "date": "2023-07-10T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-018882"
      },
      {
        "date": "2022-03-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1571"
      },
      {
        "date": "2022-03-17T13:15:07.593000",
        "db": "NVD",
        "id": "CVE-2021-44262"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-03-24T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-22306"
      },
      {
        "date": "2023-07-10T08:22:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-018882"
      },
      {
        "date": "2022-03-24T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1571"
      },
      {
        "date": "2024-11-21T06:30:41.140000",
        "db": "NVD",
        "id": "CVE-2021-44262"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1571"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Vulnerability related to lack of authentication for important functions in multiple NETGEAR products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018882"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "access control error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1571"
      }
    ],
    "trust": 0.6
  }
}

var-202203-0651
Vulnerability from variot

A vulnerability is in the 'BRS_top.html' page of the Netgear W104, version WAC104-V1.0.4.13, which can allow a remote attacker to access this page without any authentication. When processed, it exposes firmware version information for the device. WAC104 firmware, R7450 firmware, R6900 Multiple NETGEAR products, such as firmware, have vulnerabilities related to lack of authentication for important functions.Information may be obtained. Netgear W104 is a wireless access point from Netgear Corporation of the United States. The vulnerability stems from the lack of protection and permission restrictions for sensitive information on the BRS_top.html page

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202203-0651",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "r7800",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "netgear",
        "version": "*"
      },
      {
        "model": "r6900",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "netgear",
        "version": "*"
      },
      {
        "model": "wac104",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "netgear",
        "version": "1.0.4.13"
      },
      {
        "model": "r6220",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "netgear",
        "version": "1.1.0.34_1.0.1"
      },
      {
        "model": "r7450",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "netgear",
        "version": "*"
      },
      {
        "model": "wac104",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": null
      },
      {
        "model": "r6220",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": null
      },
      {
        "model": "r6900",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": null
      },
      {
        "model": "r7450",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": null
      },
      {
        "model": "r7800",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": null
      },
      {
        "model": "wac104",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "netgear",
        "version": "\u003c=1.0.4.13"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-22305"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018883"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-44261"
      }
    ]
  },
  "cve": "CVE-2021-44261",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2021-44261",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-22305",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 3.9,
            "id": "CVE-2021-44261",
            "impactScore": 1.4,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 5.3,
            "baseSeverity": "Medium",
            "confidentialityImpact": "Low",
            "exploitabilityScore": null,
            "id": "CVE-2021-44261",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2021-44261",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2021-44261",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-22305",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202203-1574",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-22305"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018883"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1574"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-44261"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability is in the \u0027BRS_top.html\u0027 page of the Netgear W104, version WAC104-V1.0.4.13, which can allow a remote attacker to access this page without any authentication. When processed, it exposes firmware version information for the device. WAC104 firmware, R7450 firmware, R6900 Multiple NETGEAR products, such as firmware, have vulnerabilities related to lack of authentication for important functions.Information may be obtained. Netgear W104 is a wireless access point from Netgear Corporation of the United States. The vulnerability stems from the lack of protection and permission restrictions for sensitive information on the BRS_top.html page",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-44261"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018883"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-22305"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-44261",
        "trust": 3.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018883",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-22305",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1574",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-22305"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018883"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1574"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-44261"
      }
    ]
  },
  "id": "VAR-202203-0651",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-22305"
      }
    ],
    "trust": 1.0457565825
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-22305"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:24:57.780000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-306",
        "trust": 1.0
      },
      {
        "problemtype": "Lack of authentication for critical features (CWE-306) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018883"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-44261"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/zer0yu/cve_request/blob/master/netgear/netgear_w104_unauthorized_access_vulnerability_first.md"
      },
      {
        "trust": 2.4,
        "url": "https://www.netgear.com/about/security/"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-44261"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2021-44261/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-22305"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018883"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1574"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-44261"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-22305"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018883"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1574"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-44261"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-03-24T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-22305"
      },
      {
        "date": "2023-07-10T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-018883"
      },
      {
        "date": "2022-03-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1574"
      },
      {
        "date": "2022-03-17T13:15:07.550000",
        "db": "NVD",
        "id": "CVE-2021-44261"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-03-24T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-22305"
      },
      {
        "date": "2023-07-10T08:22:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-018883"
      },
      {
        "date": "2022-03-24T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1574"
      },
      {
        "date": "2024-11-21T06:30:40.947000",
        "db": "NVD",
        "id": "CVE-2021-44261"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1574"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Vulnerability related to lack of authentication for important functions in multiple NETGEAR products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018883"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "access control error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1574"
      }
    ],
    "trust": 0.6
  }
}

var-202108-1659
Vulnerability from variot

NETGEAR WAC104 devices before 1.0.4.15 are affected by incorrect configuration of security settings. NETGEAR WAC104 There is an unspecified vulnerability in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202108-1659",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "wac104",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "netgear",
        "version": "1.0.4.15"
      },
      {
        "model": "wac104",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": null
      },
      {
        "model": "wac104",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": "wac104  firmware  1.0.4.15"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010448"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-38532"
      }
    ]
  },
  "cve": "CVE-2021-38532",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "CVE-2021-38532",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.2,
            "id": "CVE-2021-38532",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "cve@mitre.org",
            "availabilityImpact": "HIGH",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 0.9,
            "id": "CVE-2021-38532",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.2,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2021-38532",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "High",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2021-38532",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "cve@mitre.org",
            "id": "CVE-2021-38532",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2021-38532",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202108-947",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2021-38532",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2021-38532"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010448"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202108-947"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-38532"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-38532"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "NETGEAR WAC104 devices before 1.0.4.15 are affected by incorrect configuration of security settings. NETGEAR WAC104 There is an unspecified vulnerability in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-38532"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010448"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-38532"
      }
    ],
    "trust": 1.71
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-38532",
        "trust": 3.3
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010448",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202108-947",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-38532",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2021-38532"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010448"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202108-947"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-38532"
      }
    ]
  },
  "id": "VAR-202108-1659",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.54285717
  },
  "last_update_date": "2024-08-14T15:06:45.354000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Security\u00a0Advisory\u00a0for\u00a0Security\u00a0Misconfiguration\u00a0on\u00a0WAC104,\u00a0PSV-2021-0124",
        "trust": 0.8,
        "url": "https://kb.netgear.com/000063787/Security-Advisory-for-Security-Misconfiguration-on-WAC104-PSV-2021-0124"
      },
      {
        "title": "Netgear NETGEAR  and NETGEAR WAC104 Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=159341"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010448"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202108-947"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "NVD-CWE-noinfo",
        "trust": 1.0
      },
      {
        "problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010448"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-38532"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.7,
        "url": "https://kb.netgear.com/000063787/security-advisory-for-security-misconfiguration-on-wac104-psv-2021-0124"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-38532"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2021-38532"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010448"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202108-947"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-38532"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULMON",
        "id": "CVE-2021-38532"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010448"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202108-947"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-38532"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-08-11T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-38532"
      },
      {
        "date": "2022-07-01T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-010448"
      },
      {
        "date": "2021-08-10T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202108-947"
      },
      {
        "date": "2021-08-11T00:17:12.687000",
        "db": "NVD",
        "id": "CVE-2021-38532"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-08-19T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-38532"
      },
      {
        "date": "2022-07-01T06:12:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-010448"
      },
      {
        "date": "2021-08-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202108-947"
      },
      {
        "date": "2021-08-19T12:38:47.213000",
        "db": "NVD",
        "id": "CVE-2021-38532"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202108-947"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "NETGEAR\u00a0WAC104\u00a0 Vulnerabilities in devices",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010448"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202108-947"
      }
    ],
    "trust": 0.6
  }
}

var-202012-1187
Vulnerability from variot

NETGEAR WAC104 devices before 1.0.4.13 are affected by a buffer overflow by an authenticated user. NETGEAR WAC104 A classic buffer overflow vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. NETGEAR WAC104 is a dual-band 802.11ac 1.2Gbps wireless access point. No detailed vulnerability details are currently provided

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202012-1187",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "wac104",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "netgear",
        "version": "1.0.4.13"
      },
      {
        "model": "wac104",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": null
      },
      {
        "model": "wac104",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": "wac104  firmware  1.0.4.13"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-75522"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-014980"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-35788"
      }
    ]
  },
  "cve": "CVE-2020-35788",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "SINGLE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.2,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 5.1,
            "id": "CVE-2020-35788",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.2,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 5.1,
            "id": "CNVD-2020-75522",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 0.9,
            "id": "CVE-2020-35788",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT",
            "author": "cve@mitre.org",
            "availabilityImpact": "HIGH",
            "baseScore": 7.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.0,
            "id": "CVE-2020-35788",
            "impactScore": 6.0,
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Adjacent Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 6.8,
            "baseSeverity": "Medium",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2020-35788",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "High",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-35788",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "cve@mitre.org",
            "id": "CVE-2020-35788",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2020-35788",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2020-75522",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202012-1786",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-75522"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-014980"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202012-1786"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-35788"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-35788"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "NETGEAR WAC104 devices before 1.0.4.13 are affected by a buffer overflow by an authenticated user. NETGEAR WAC104 A classic buffer overflow vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. NETGEAR WAC104 is a dual-band 802.11ac 1.2Gbps wireless access point. No detailed vulnerability details are currently provided",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-35788"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-014980"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-75522"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-35788",
        "trust": 3.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-014980",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-75522",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202012-1786",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-75522"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-014980"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202012-1786"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-35788"
      }
    ]
  },
  "id": "VAR-202012-1187",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-75522"
      }
    ],
    "trust": 1.14285717
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-75522"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:20:55.199000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Buffer\u00a0Overflow\u00a0on\u00a0WAC104,\u00a0PSV-2020-0319",
        "trust": 0.8,
        "url": "https://kb.netgear.com/000062719/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-WAC104-PSV-2020-0319"
      },
      {
        "title": "Patch for NETGEAR WAC104 buffer overflow vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/242989"
      },
      {
        "title": "NETGEAR WAC devices Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=138287"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-75522"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-014980"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202012-1786"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      },
      {
        "problemtype": "Classic buffer overflow (CWE-120) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-014980"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-35788"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.0,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-35788"
      },
      {
        "trust": 1.6,
        "url": "https://kb.netgear.com/000062719/security-advisory-for-post-authentication-buffer-overflow-on-wac104-psv-2020-0319"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-75522"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-014980"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202012-1786"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-35788"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-75522"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-014980"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202012-1786"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-35788"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-12-31T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-75522"
      },
      {
        "date": "2021-09-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-014980"
      },
      {
        "date": "2020-12-29T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202012-1786"
      },
      {
        "date": "2020-12-30T00:15:13.597000",
        "db": "NVD",
        "id": "CVE-2020-35788"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-12-31T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-75522"
      },
      {
        "date": "2021-09-07T06:17:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-014980"
      },
      {
        "date": "2021-01-05T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202012-1786"
      },
      {
        "date": "2024-11-21T05:28:06.053000",
        "db": "NVD",
        "id": "CVE-2020-35788"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote or local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202012-1786"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "NETGEAR\u00a0WAC104\u00a0 Classic buffer overflow vulnerability in device",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-014980"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202012-1786"
      }
    ],
    "trust": 0.6
  }
}