Vulnerabilites related to draytek - vigorconnect
Vulnerability from fkie_nvd
Published
2021-10-13 16:15
Modified
2024-11-21 05:45
Severity ?
Summary
An arbitrary file deletion vulnerability exists in the file delete functionality of the Html5Servlet endpoint of Draytek VigorConnect 1.6.0-B3. This allows an authenticated user to arbitrarily delete files in any location on the target operating system with root privileges.
References
▼ | URL | Tags | |
---|---|---|---|
vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
draytek | vigorconnect | 1.6.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*", "matchCriteriaId": "CC518B3A-EDB0-434A-8CF5-026437FF5A13", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An arbitrary file deletion vulnerability exists in the file delete functionality of the Html5Servlet endpoint of Draytek VigorConnect 1.6.0-B3. This allows an authenticated user to arbitrarily delete files in any location on the target operating system with root privileges." }, { "lang": "es", "value": "Se presenta una vulnerabilidad de eliminaci\u00f3n arbitraria de archivos en la funcionalidad file delete del endpoint Html5Servlet de Draytek VigorConnect versi\u00f3n 1.6.0-B3. Esto permite a un usuario autenticado eliminar arbitrariamente archivos en cualquier ubicaci\u00f3n del sistema operativo de destino con privilegios de root" } ], "id": "CVE-2021-20127", "lastModified": "2024-11-21T05:45:58.587", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 8.5, "confidentialityImpact": "NONE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:N/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 9.2, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.2, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-10-13T16:15:07.517", "references": [ { "source": "vulnreport@tenable.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://www.tenable.com/security/research/tra-2021-42" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://www.tenable.com/security/research/tra-2021-42" } ], "sourceIdentifier": "vulnreport@tenable.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-10-13 16:15
Modified
2024-11-21 05:45
Severity ?
Summary
An information disclosure vulnerability exists in Draytek VigorConnect 1.6.0-B3, allowing an unauthenticated attacker to export system logs.
References
▼ | URL | Tags | |
---|---|---|---|
vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
draytek | vigorconnect | 1.6.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*", "matchCriteriaId": "CC518B3A-EDB0-434A-8CF5-026437FF5A13", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An information disclosure vulnerability exists in Draytek VigorConnect 1.6.0-B3, allowing an unauthenticated attacker to export system logs." }, { "lang": "es", "value": "Se presenta una vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n en Draytek VigorConnect versi\u00f3n 1.6.0-B3, que permite a un atacante no autenticado exportar los registros del sistema" } ], "id": "CVE-2021-20129", "lastModified": "2024-11-21T05:45:58.793", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-10-13T16:15:07.600", "references": [ { "source": "vulnreport@tenable.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://www.tenable.com/security/research/tra-2021-42" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://www.tenable.com/security/research/tra-2021-42" } ], "sourceIdentifier": "vulnreport@tenable.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-532" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-10-13 16:15
Modified
2025-03-12 21:00
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Summary
A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the WebServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges.
References
▼ | URL | Tags | |
---|---|---|---|
vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
draytek | vigorconnect | 1.6.0 |
{ "cisaActionDue": "2024-09-24", "cisaExploitAdd": "2024-09-03", "cisaRequiredAction": "Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.", "cisaVulnerabilityName": "Draytek VigorConnect Path Traversal Vulnerability ", "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*", "matchCriteriaId": "CC518B3A-EDB0-434A-8CF5-026437FF5A13", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the WebServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges." }, { "lang": "es", "value": "Se presenta una vulnerabilidad de inclusi\u00f3n de archivos locales en Draytek VigorConnect versi\u00f3n 1.6.0-B3, en la funcionalidad file download del endpoint WebServlet. Un atacante no autenticado podr\u00eda aprovechar esta vulnerabilidad para descargar archivos arbitrarios desde el sistema operativo subyacente con privilegios de root" } ], "id": "CVE-2021-20124", "lastModified": "2025-03-12T21:00:57.580", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 7.8, "confidentialityImpact": "COMPLETE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2021-10-13T16:15:07.397", "references": [ { "source": "vulnreport@tenable.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://www.tenable.com/security/research/tra-2021-42" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://www.tenable.com/security/research/tra-2021-42" } ], "sourceIdentifier": "vulnreport@tenable.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2021-10-13 16:15
Modified
2024-11-21 05:45
Severity ?
Summary
An arbitrary file upload and directory traversal vulnerability exists in the file upload functionality of DownloadFileServlet in Draytek VigorConnect 1.6.0-B3. An unauthenticated attacker could leverage this vulnerability to upload files to any location on the target operating system with root privileges.
References
▼ | URL | Tags | |
---|---|---|---|
vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
draytek | vigorconnect | 1.6.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*", "matchCriteriaId": "CC518B3A-EDB0-434A-8CF5-026437FF5A13", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An arbitrary file upload and directory traversal vulnerability exists in the file upload functionality of DownloadFileServlet in Draytek VigorConnect 1.6.0-B3. An unauthenticated attacker could leverage this vulnerability to upload files to any location on the target operating system with root privileges." }, { "lang": "es", "value": "Se presenta una vulnerabilidad de carga arbitraria de archivos y de salto de directorio en la funcionalidad upload functionality de DownloadFileServlet en Draytek VigorConnect versi\u00f3n 1.6.0-B3. Un atacante no autenticado podr\u00eda aprovechar esta vulnerabilidad para subir archivos a cualquier ubicaci\u00f3n en el sistema operativo de destino con privilegios de root" } ], "id": "CVE-2021-20125", "lastModified": "2024-11-21T05:45:58.373", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-10-13T16:15:07.437", "references": [ { "source": "vulnreport@tenable.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://www.tenable.com/security/research/tra-2021-42" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://www.tenable.com/security/research/tra-2021-42" } ], "sourceIdentifier": "vulnreport@tenable.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-22" }, { "lang": "en", "value": "CWE-434" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-10-13 16:15
Modified
2024-11-21 05:45
Severity ?
Summary
Draytek VigorConnect 1.6.0-B3 lacks cross-site request forgery protections and does not sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request.
References
▼ | URL | Tags | |
---|---|---|---|
vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
draytek | vigorconnect | 1.6.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*", "matchCriteriaId": "CC518B3A-EDB0-434A-8CF5-026437FF5A13", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Draytek VigorConnect 1.6.0-B3 lacks cross-site request forgery protections and does not sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request." }, { "lang": "es", "value": "Draytek VigorConnect versi\u00f3n 1.6.0-B3, carece de protecciones contra vulnerabilidades de tipo cross-site request forgery y no comprueba suficientemente si una petici\u00f3n bien formada, v\u00e1lida y consistente fue proporcionada intencionadamente por el usuario que envi\u00f3 la petici\u00f3n" } ], "id": "CVE-2021-20126", "lastModified": "2024-11-21T05:45:58.490", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-10-13T16:15:07.477", "references": [ { "source": "vulnreport@tenable.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://www.tenable.com/security/research/tra-2021-42" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://www.tenable.com/security/research/tra-2021-42" } ], "sourceIdentifier": "vulnreport@tenable.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-352" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-10-13 16:15
Modified
2024-11-21 05:45
Severity ?
Summary
The Profile Name field in the floor plan (Network Menu) page in Draytek VigorConnect 1.6.0-B3 was found to be vulnerable to stored XSS, as user input is not properly sanitized.
References
▼ | URL | Tags | |
---|---|---|---|
vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
draytek | vigorconnect | 1.6.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*", "matchCriteriaId": "CC518B3A-EDB0-434A-8CF5-026437FF5A13", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "The Profile Name field in the floor plan (Network Menu) page in Draytek VigorConnect 1.6.0-B3 was found to be vulnerable to stored XSS, as user input is not properly sanitized." }, { "lang": "es", "value": "El campo Profile Name en la p\u00e1gina floor plan (Network Menu) en Draytek VigorConnect versi\u00f3n 1.6.0-B3 se ha encontrado que es vulnerable a un ataque de tipo XSS almacenado, ya que la entrada del usuario no est\u00e1 saneada apropiadamente" } ], "id": "CVE-2021-20128", "lastModified": "2024-11-21T05:45:58.697", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 6.8, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.3, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-10-13T16:15:07.557", "references": [ { "source": "vulnreport@tenable.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://www.tenable.com/security/research/tra-2021-42" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://www.tenable.com/security/research/tra-2021-42" } ], "sourceIdentifier": "vulnreport@tenable.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-10-13 16:15
Modified
2025-03-12 21:00
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Summary
A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the DownloadFileServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges.
References
▼ | URL | Tags | |
---|---|---|---|
vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2021-42 | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
draytek | vigorconnect | 1.6.0 |
{ "cisaActionDue": "2024-09-24", "cisaExploitAdd": "2024-09-03", "cisaRequiredAction": "Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.", "cisaVulnerabilityName": "Draytek VigorConnect Path Traversal Vulnerability ", "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*", "matchCriteriaId": "CC518B3A-EDB0-434A-8CF5-026437FF5A13", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the DownloadFileServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges." }, { "lang": "es", "value": "Se presenta una vulnerabilidad de inclusi\u00f3n de archivos locales en Draytek VigorConnect versi\u00f3n 1.6.0-B3, en la funcionalidad file download del endpoint DownloadFileServlet. Un atacante no autenticado podr\u00eda aprovechar esta vulnerabilidad para descargar archivos arbitrarios del sistema operativo subyacente con privilegios de root" } ], "id": "CVE-2021-20123", "lastModified": "2025-03-12T21:00:51.317", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 7.8, "confidentialityImpact": "COMPLETE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2021-10-13T16:15:07.350", "references": [ { "source": "vulnreport@tenable.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://www.tenable.com/security/research/tra-2021-42" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://www.tenable.com/security/research/tra-2021-42" } ], "sourceIdentifier": "vulnreport@tenable.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
CVE-2021-20128 (GCVE-0-2021-20128)
Vulnerability from cvelistv5
Published
2021-10-13 15:49
Modified
2024-08-03 17:30
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- Cross-site Scripting
Summary
The Profile Name field in the floor plan (Network Menu) page in Draytek VigorConnect 1.6.0-B3 was found to be vulnerable to stored XSS, as user input is not properly sanitized.
References
▼ | URL | Tags |
---|---|---|
https://www.tenable.com/security/research/tra-2021-42 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Draytek VigorConnect |
Version: 1.6.0-B3 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T17:30:07.492Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.tenable.com/security/research/tra-2021-42" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Draytek VigorConnect", "vendor": "n/a", "versions": [ { "status": "affected", "version": "1.6.0-B3" } ] } ], "descriptions": [ { "lang": "en", "value": "The Profile Name field in the floor plan (Network Menu) page in Draytek VigorConnect 1.6.0-B3 was found to be vulnerable to stored XSS, as user input is not properly sanitized." } ], "problemTypes": [ { "descriptions": [ { "description": "Cross-site Scripting", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-13T15:49:30", "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "shortName": "tenable" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.tenable.com/security/research/tra-2021-42" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnreport@tenable.com", "ID": "CVE-2021-20128", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Draytek VigorConnect", "version": { "version_data": [ { "version_value": "1.6.0-B3" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The Profile Name field in the floor plan (Network Menu) page in Draytek VigorConnect 1.6.0-B3 was found to be vulnerable to stored XSS, as user input is not properly sanitized." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Cross-site Scripting" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.tenable.com/security/research/tra-2021-42", "refsource": "MISC", "url": "https://www.tenable.com/security/research/tra-2021-42" } ] } } } }, "cveMetadata": { "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "assignerShortName": "tenable", "cveId": "CVE-2021-20128", "datePublished": "2021-10-13T15:49:30", "dateReserved": "2020-12-17T00:00:00", "dateUpdated": "2024-08-03T17:30:07.492Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-20125 (GCVE-0-2021-20125)
Vulnerability from cvelistv5
Published
2021-10-13 15:48
Modified
2024-08-03 17:30
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- Unrestricted Upload of File with Dangerous Type
Summary
An arbitrary file upload and directory traversal vulnerability exists in the file upload functionality of DownloadFileServlet in Draytek VigorConnect 1.6.0-B3. An unauthenticated attacker could leverage this vulnerability to upload files to any location on the target operating system with root privileges.
References
▼ | URL | Tags |
---|---|---|
https://www.tenable.com/security/research/tra-2021-42 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Draytek VigorConnect |
Version: 1.6.0-B3 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T17:30:07.504Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.tenable.com/security/research/tra-2021-42" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Draytek VigorConnect", "vendor": "n/a", "versions": [ { "status": "affected", "version": "1.6.0-B3" } ] } ], "descriptions": [ { "lang": "en", "value": "An arbitrary file upload and directory traversal vulnerability exists in the file upload functionality of DownloadFileServlet in Draytek VigorConnect 1.6.0-B3. An unauthenticated attacker could leverage this vulnerability to upload files to any location on the target operating system with root privileges." } ], "problemTypes": [ { "descriptions": [ { "description": "Unrestricted Upload of File with Dangerous Type", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-13T15:48:08", "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "shortName": "tenable" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.tenable.com/security/research/tra-2021-42" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnreport@tenable.com", "ID": "CVE-2021-20125", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Draytek VigorConnect", "version": { "version_data": [ { "version_value": "1.6.0-B3" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An arbitrary file upload and directory traversal vulnerability exists in the file upload functionality of DownloadFileServlet in Draytek VigorConnect 1.6.0-B3. An unauthenticated attacker could leverage this vulnerability to upload files to any location on the target operating system with root privileges." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Unrestricted Upload of File with Dangerous Type" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.tenable.com/security/research/tra-2021-42", "refsource": "MISC", "url": "https://www.tenable.com/security/research/tra-2021-42" } ] } } } }, "cveMetadata": { "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "assignerShortName": "tenable", "cveId": "CVE-2021-20125", "datePublished": "2021-10-13T15:48:08", "dateReserved": "2020-12-17T00:00:00", "dateUpdated": "2024-08-03T17:30:07.504Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-20129 (GCVE-0-2021-20129)
Vulnerability from cvelistv5
Published
2021-10-13 15:49
Modified
2024-08-03 17:30
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- Exposure of Sensitive Information to an Unauthorized Actor
Summary
An information disclosure vulnerability exists in Draytek VigorConnect 1.6.0-B3, allowing an unauthenticated attacker to export system logs.
References
▼ | URL | Tags |
---|---|---|
https://www.tenable.com/security/research/tra-2021-42 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Draytek VigorConnect |
Version: 1.6.0-B3 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T17:30:07.422Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.tenable.com/security/research/tra-2021-42" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Draytek VigorConnect", "vendor": "n/a", "versions": [ { "status": "affected", "version": "1.6.0-B3" } ] } ], "descriptions": [ { "lang": "en", "value": "An information disclosure vulnerability exists in Draytek VigorConnect 1.6.0-B3, allowing an unauthenticated attacker to export system logs." } ], "problemTypes": [ { "descriptions": [ { "description": "Exposure of Sensitive Information to an Unauthorized Actor", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-13T15:49:35", "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "shortName": "tenable" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.tenable.com/security/research/tra-2021-42" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnreport@tenable.com", "ID": "CVE-2021-20129", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Draytek VigorConnect", "version": { "version_data": [ { "version_value": "1.6.0-B3" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An information disclosure vulnerability exists in Draytek VigorConnect 1.6.0-B3, allowing an unauthenticated attacker to export system logs." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Exposure of Sensitive Information to an Unauthorized Actor" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.tenable.com/security/research/tra-2021-42", "refsource": "MISC", "url": "https://www.tenable.com/security/research/tra-2021-42" } ] } } } }, "cveMetadata": { "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "assignerShortName": "tenable", "cveId": "CVE-2021-20129", "datePublished": "2021-10-13T15:49:35", "dateReserved": "2020-12-17T00:00:00", "dateUpdated": "2024-08-03T17:30:07.422Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-20124 (GCVE-0-2021-20124)
Vulnerability from cvelistv5
Published
2021-10-13 15:48
Modified
2025-07-30 01:37
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- Path Traversal
Summary
A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the WebServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges.
References
▼ | URL | Tags |
---|---|---|
https://www.tenable.com/security/research/tra-2021-42 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Draytek VigorConnect |
Version: 1.6.0-B3 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T17:30:07.526Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.tenable.com/security/research/tra-2021-42" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "vigorconnect", "vendor": "draytek", "versions": [ { "status": "affected", "version": "1.6.0" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2021-20124", "options": [ { "Exploitation": "active" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-09-03T12:28:51.460379Z", "version": "2.0.3" }, "type": "ssvc" } }, { "other": { "content": { "dateAdded": "2024-09-03", "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-20124" }, "type": "kev" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-07-30T01:37:54.971Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "timeline": [ { "lang": "en", "time": "2024-09-03T00:00:00+00:00", "value": "CVE-2021-20124 added to CISA KEV" } ], "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "Draytek VigorConnect", "vendor": "n/a", "versions": [ { "status": "affected", "version": "1.6.0-B3" } ] } ], "descriptions": [ { "lang": "en", "value": "A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the WebServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges." } ], "problemTypes": [ { "descriptions": [ { "description": "Path Traversal", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-13T15:48:03.000Z", "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "shortName": "tenable" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.tenable.com/security/research/tra-2021-42" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnreport@tenable.com", "ID": "CVE-2021-20124", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Draytek VigorConnect", "version": { "version_data": [ { "version_value": "1.6.0-B3" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the WebServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Path Traversal" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.tenable.com/security/research/tra-2021-42", "refsource": "MISC", "url": "https://www.tenable.com/security/research/tra-2021-42" } ] } } } }, "cveMetadata": { "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "assignerShortName": "tenable", "cveId": "CVE-2021-20124", "datePublished": "2021-10-13T15:48:03.000Z", "dateReserved": "2020-12-17T00:00:00.000Z", "dateUpdated": "2025-07-30T01:37:54.971Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-20127 (GCVE-0-2021-20127)
Vulnerability from cvelistv5
Published
2021-10-13 15:49
Modified
2024-08-03 17:30
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- Improper Access Control
Summary
An arbitrary file deletion vulnerability exists in the file delete functionality of the Html5Servlet endpoint of Draytek VigorConnect 1.6.0-B3. This allows an authenticated user to arbitrarily delete files in any location on the target operating system with root privileges.
References
▼ | URL | Tags |
---|---|---|
https://www.tenable.com/security/research/tra-2021-42 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Draytek VigorConnect |
Version: 1.6.0-B3 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T17:30:07.367Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.tenable.com/security/research/tra-2021-42" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Draytek VigorConnect", "vendor": "n/a", "versions": [ { "status": "affected", "version": "1.6.0-B3" } ] } ], "descriptions": [ { "lang": "en", "value": "An arbitrary file deletion vulnerability exists in the file delete functionality of the Html5Servlet endpoint of Draytek VigorConnect 1.6.0-B3. This allows an authenticated user to arbitrarily delete files in any location on the target operating system with root privileges." } ], "problemTypes": [ { "descriptions": [ { "description": "Improper Access Control", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-13T15:49:25", "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "shortName": "tenable" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.tenable.com/security/research/tra-2021-42" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnreport@tenable.com", "ID": "CVE-2021-20127", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Draytek VigorConnect", "version": { "version_data": [ { "version_value": "1.6.0-B3" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An arbitrary file deletion vulnerability exists in the file delete functionality of the Html5Servlet endpoint of Draytek VigorConnect 1.6.0-B3. This allows an authenticated user to arbitrarily delete files in any location on the target operating system with root privileges." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Improper Access Control" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.tenable.com/security/research/tra-2021-42", "refsource": "MISC", "url": "https://www.tenable.com/security/research/tra-2021-42" } ] } } } }, "cveMetadata": { "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "assignerShortName": "tenable", "cveId": "CVE-2021-20127", "datePublished": "2021-10-13T15:49:25", "dateReserved": "2020-12-17T00:00:00", "dateUpdated": "2024-08-03T17:30:07.367Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-20126 (GCVE-0-2021-20126)
Vulnerability from cvelistv5
Published
2021-10-13 15:48
Modified
2024-08-03 17:30
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- Cross-Site Request Forgery
Summary
Draytek VigorConnect 1.6.0-B3 lacks cross-site request forgery protections and does not sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request.
References
▼ | URL | Tags |
---|---|---|
https://www.tenable.com/security/research/tra-2021-42 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Draytek VigorConnect |
Version: 1.6.0-B3 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T17:30:07.598Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.tenable.com/security/research/tra-2021-42" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Draytek VigorConnect", "vendor": "n/a", "versions": [ { "status": "affected", "version": "1.6.0-B3" } ] } ], "descriptions": [ { "lang": "en", "value": "Draytek VigorConnect 1.6.0-B3 lacks cross-site request forgery protections and does not sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request." } ], "problemTypes": [ { "descriptions": [ { "description": "Cross-Site Request Forgery", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-13T15:48:15", "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "shortName": "tenable" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.tenable.com/security/research/tra-2021-42" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnreport@tenable.com", "ID": "CVE-2021-20126", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Draytek VigorConnect", "version": { "version_data": [ { "version_value": "1.6.0-B3" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Draytek VigorConnect 1.6.0-B3 lacks cross-site request forgery protections and does not sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Cross-Site Request Forgery" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.tenable.com/security/research/tra-2021-42", "refsource": "MISC", "url": "https://www.tenable.com/security/research/tra-2021-42" } ] } } } }, "cveMetadata": { "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "assignerShortName": "tenable", "cveId": "CVE-2021-20126", "datePublished": "2021-10-13T15:48:15", "dateReserved": "2020-12-17T00:00:00", "dateUpdated": "2024-08-03T17:30:07.598Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-20123 (GCVE-0-2021-20123)
Vulnerability from cvelistv5
Published
2021-10-13 15:47
Modified
2025-07-30 01:37
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- Path Traversal
Summary
A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the DownloadFileServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges.
References
▼ | URL | Tags |
---|---|---|
https://www.tenable.com/security/research/tra-2021-42 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Draytek VigorConnect |
Version: 1.6.0-B3 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T17:30:07.620Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.tenable.com/security/research/tra-2021-42" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:a:draytek:vigorconnect:1.6.0:beta3:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "vigorconnect", "vendor": "draytek", "versions": [ { "status": "affected", "version": "1.6.0" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2021-20123", "options": [ { "Exploitation": "active" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-09-03T12:29:01.834786Z", "version": "2.0.3" }, "type": "ssvc" } }, { "other": { "content": { "dateAdded": "2024-09-03", "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-20123" }, "type": "kev" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-07-30T01:37:55.122Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "timeline": [ { "lang": "en", "time": "2024-09-03T00:00:00+00:00", "value": "CVE-2021-20123 added to CISA KEV" } ], "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "Draytek VigorConnect", "vendor": "n/a", "versions": [ { "status": "affected", "version": "1.6.0-B3" } ] } ], "descriptions": [ { "lang": "en", "value": "A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the DownloadFileServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges." } ], "problemTypes": [ { "descriptions": [ { "description": "Path Traversal", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-13T15:47:58.000Z", "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "shortName": "tenable" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.tenable.com/security/research/tra-2021-42" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnreport@tenable.com", "ID": "CVE-2021-20123", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Draytek VigorConnect", "version": { "version_data": [ { "version_value": "1.6.0-B3" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A local file inclusion vulnerability exists in Draytek VigorConnect 1.6.0-B3 in the file download functionality of the DownloadFileServlet endpoint. An unauthenticated attacker could leverage this vulnerability to download arbitrary files from the underlying operating system with root privileges." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Path Traversal" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.tenable.com/security/research/tra-2021-42", "refsource": "MISC", "url": "https://www.tenable.com/security/research/tra-2021-42" } ] } } } }, "cveMetadata": { "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "assignerShortName": "tenable", "cveId": "CVE-2021-20123", "datePublished": "2021-10-13T15:47:58.000Z", "dateReserved": "2020-12-17T00:00:00.000Z", "dateUpdated": "2025-07-30T01:37:55.122Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }