Vulnerabilites related to siemens - syngo_dynamics_cardiovascular_imaging_and_information_system
CVE-2022-42732 (GCVE-0-2022-42732)
Vulnerability from cvelistv5
Published
2022-11-17 00:00
Modified
2025-04-29 20:14
CWE
  • CWE-73 - External Control of File Name or Path
Summary
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper read access control that could allow files to be retrieved from any folder accessible to the account assigned to the website’s application pool.
Impacted products
Vendor Product Version
Siemens syngo Dynamics Version: All versions < VA40G HF01
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:10:41.432Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-42732",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-29T20:14:28.461375Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-29T20:14:50.207Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "syngo Dynamics",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c VA40G HF01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in syngo Dynamics (All versions \u003c VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper read access control that could allow files to be retrieved from any folder accessible to the account assigned to the website\u2019s application pool."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-73",
              "description": "CWE-73: External Control of File Name or Path",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-17T00:00:00.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-42732",
    "datePublished": "2022-11-17T00:00:00.000Z",
    "dateReserved": "2022-10-10T00:00:00.000Z",
    "dateUpdated": "2025-04-29T20:14:50.207Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-42894 (GCVE-0-2022-42894)
Vulnerability from cvelistv5
Published
2022-11-17 00:00
Modified
2025-04-30 14:38
CWE
  • CWE-918 - Server-Side Request Forgery (SSRF)
Summary
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). An unauthenticated Server-Side Request Forgery (SSRF) vulnerability was identified in one of the web services exposed on the syngo Dynamics application that could allow for the leaking of NTLM credentials as well as local service enumeration.
Impacted products
Vendor Product Version
Siemens syngo Dynamics Version: All versions < VA40G HF01
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:19:05.437Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-42894",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-30T14:38:31.801484Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-30T14:38:51.901Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "syngo Dynamics",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c VA40G HF01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in syngo Dynamics (All versions \u003c VA40G HF01). An unauthenticated Server-Side Request Forgery (SSRF) vulnerability was identified in one of the web services exposed on the syngo Dynamics application that could allow for the leaking of NTLM credentials as well as local service enumeration."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-918",
              "description": "CWE-918: Server-Side Request Forgery (SSRF)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-17T00:00:00.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-42894",
    "datePublished": "2022-11-17T00:00:00.000Z",
    "dateReserved": "2022-10-12T00:00:00.000Z",
    "dateUpdated": "2025-04-30T14:38:51.901Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-42734 (GCVE-0-2022-42734)
Vulnerability from cvelistv5
Published
2022-11-17 00:00
Modified
2025-04-29 19:57
CWE
  • CWE-73 - External Control of File Name or Path
Summary
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper write access control that could allow to write data in any folder accessible to the account assigned to the website’s application pool.
Impacted products
Vendor Product Version
Siemens syngo Dynamics Version: All versions < VA40G HF01
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:10:41.453Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-42734",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-29T19:57:45.565163Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-29T19:57:57.946Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "syngo Dynamics",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c VA40G HF01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in syngo Dynamics (All versions \u003c VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper write access control that could allow to write data in any folder accessible to the account assigned to the website\u2019s application pool."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-73",
              "description": "CWE-73: External Control of File Name or Path",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-17T00:00:00.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-42734",
    "datePublished": "2022-11-17T00:00:00.000Z",
    "dateReserved": "2022-10-10T00:00:00.000Z",
    "dateUpdated": "2025-04-29T19:57:57.946Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-42893 (GCVE-0-2022-42893)
Vulnerability from cvelistv5
Published
2022-11-17 00:00
Modified
2025-04-30 14:39
CWE
  • CWE-73 - External Control of File Name or Path
Summary
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper write access control that could allow to write data in any folder accessible to the account assigned to the website’s application pool.
Impacted products
Vendor Product Version
Siemens syngo Dynamics Version: All versions < VA40G HF01
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:19:05.213Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-42893",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-30T14:39:25.509058Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-30T14:39:48.150Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "syngo Dynamics",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c VA40G HF01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in syngo Dynamics (All versions \u003c VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper write access control that could allow to write data in any folder accessible to the account assigned to the website\u2019s application pool."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-73",
              "description": "CWE-73: External Control of File Name or Path",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-17T00:00:00.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-42893",
    "datePublished": "2022-11-17T00:00:00.000Z",
    "dateReserved": "2022-10-12T00:00:00.000Z",
    "dateUpdated": "2025-04-30T14:39:48.150Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-42733 (GCVE-0-2022-42733)
Vulnerability from cvelistv5
Published
2022-11-17 00:00
Modified
2025-04-29 19:58
CWE
  • CWE-73 - External Control of File Name or Path
Summary
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper read access control that could allow files to be retrieved from any folder accessible to the account assigned to the website’s application pool.
Impacted products
Vendor Product Version
Siemens syngo Dynamics Version: All versions < VA40G HF01
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:10:41.416Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-42733",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-29T19:58:49.053966Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-29T19:58:53.346Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "syngo Dynamics",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c VA40G HF01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in syngo Dynamics (All versions \u003c VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper read access control that could allow files to be retrieved from any folder accessible to the account assigned to the website\u2019s application pool."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-73",
              "description": "CWE-73: External Control of File Name or Path",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-17T00:00:00.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-42733",
    "datePublished": "2022-11-17T00:00:00.000Z",
    "dateReserved": "2022-10-10T00:00:00.000Z",
    "dateUpdated": "2025-04-29T19:58:53.346Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-42892 (GCVE-0-2022-42892)
Vulnerability from cvelistv5
Published
2022-11-17 00:00
Modified
2025-04-30 14:40
CWE
  • CWE-23 - Relative Path Traversal
Summary
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper write access control that could allow directory listing in any folder accessible to the account assigned to the website’s application pool.
Impacted products
Vendor Product Version
Siemens syngo Dynamics Version: All versions < VA40G HF01
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:19:05.491Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-42892",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-30T14:40:14.911424Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-30T14:40:44.703Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "syngo Dynamics",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c VA40G HF01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in syngo Dynamics (All versions \u003c VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper write access control that could allow directory listing in any folder accessible to the account assigned to the website\u2019s application pool."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-23",
              "description": "CWE-23: Relative Path Traversal",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-17T00:00:00.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-42892",
    "datePublished": "2022-11-17T00:00:00.000Z",
    "dateReserved": "2022-10-12T00:00:00.000Z",
    "dateUpdated": "2025-04-30T14:40:44.703Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-42891 (GCVE-0-2022-42891)
Vulnerability from cvelistv5
Published
2022-11-17 00:00
Modified
2025-04-29 19:57
CWE
  • CWE-73 - External Control of File Name or Path
Summary
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper write access control that could allow to write data in any folder accessible to the account assigned to the website’s application pool.
Impacted products
Vendor Product Version
Siemens syngo Dynamics Version: All versions < VA40G HF01
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:19:05.258Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-42891",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-29T19:57:04.269240Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-29T19:57:20.771Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "syngo Dynamics",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c VA40G HF01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in syngo Dynamics (All versions \u003c VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper write access control that could allow to write data in any folder accessible to the account assigned to the website\u2019s application pool."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-73",
              "description": "CWE-73: External Control of File Name or Path",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-17T00:00:00.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-42891",
    "datePublished": "2022-11-17T00:00:00.000Z",
    "dateReserved": "2022-10-12T00:00:00.000Z",
    "dateUpdated": "2025-04-29T19:57:20.771Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Vulnerability from fkie_nvd
Published
2022-11-17 17:15
Modified
2025-04-29 20:15
Summary
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper read access control that could allow files to be retrieved from any folder accessible to the account assigned to the website’s application pool.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:syngo_dynamics_cardiovascular_imaging_and_information_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2F3FBF4-8431-4C9D-8173-CA6DEC1104F0",
              "versionEndExcluding": "va40g_hf01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in syngo Dynamics (All versions \u003c VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper read access control that could allow files to be retrieved from any folder accessible to the account assigned to the website\u2019s application pool."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en syngo Dynamics (todas las versiones \u0026lt; VA40G HF01). El servidor de aplicaciones syngo Dynamics aloja un servicio web mediante una operaci\u00f3n con control de acceso de lectura inadecuado que podr\u00eda permitir recuperar archivos desde cualquier carpeta accesible a la cuenta asignada al grupo de aplicaciones del sitio web."
    }
  ],
  "id": "CVE-2022-42733",
  "lastModified": "2025-04-29T20:15:21.487",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2022-11-17T17:15:12.107",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-73"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-610"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-11-17 17:15
Modified
2025-04-30 15:15
Summary
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper write access control that could allow directory listing in any folder accessible to the account assigned to the website’s application pool.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:syngo_dynamics_cardiovascular_imaging_and_information_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2F3FBF4-8431-4C9D-8173-CA6DEC1104F0",
              "versionEndExcluding": "va40g_hf01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in syngo Dynamics (All versions \u003c VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper write access control that could allow directory listing in any folder accessible to the account assigned to the website\u2019s application pool."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en syngo Dynamics (todas las versiones \u0026lt; VA40G HF01). El servidor de aplicaciones syngo Dynamics aloja un servicio web mediante una operaci\u00f3n con control de acceso de escritura inadecuado que podr\u00eda permitir el listado de directorios en cualquier carpeta accesible a la cuenta asignada al grupo de aplicaciones del sitio web."
    }
  ],
  "id": "CVE-2022-42892",
  "lastModified": "2025-04-30T15:15:57.157",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 1.4,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 1.4,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2022-11-17T17:15:12.880",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-23"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-11-17 17:15
Modified
2025-04-30 15:15
Summary
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper write access control that could allow to write data in any folder accessible to the account assigned to the website’s application pool.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:syngo_dynamics_cardiovascular_imaging_and_information_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2F3FBF4-8431-4C9D-8173-CA6DEC1104F0",
              "versionEndExcluding": "va40g_hf01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in syngo Dynamics (All versions \u003c VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper write access control that could allow to write data in any folder accessible to the account assigned to the website\u2019s application pool."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en syngo Dynamics (todas las versiones \u0026lt; VA40G HF01). El servidor de aplicaciones syngo Dynamics aloja un servicio web mediante una operaci\u00f3n con control de acceso de escritura inadecuado que podr\u00eda permitir escribir datos en cualquier carpeta accesible a la cuenta asignada al grupo de aplicaciones del sitio web."
    }
  ],
  "id": "CVE-2022-42893",
  "lastModified": "2025-04-30T15:15:57.337",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2022-11-17T17:15:13.207",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-73"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-610"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-11-17 17:15
Modified
2025-04-30 15:15
Summary
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). An unauthenticated Server-Side Request Forgery (SSRF) vulnerability was identified in one of the web services exposed on the syngo Dynamics application that could allow for the leaking of NTLM credentials as well as local service enumeration.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:syngo_dynamics_cardiovascular_imaging_and_information_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2F3FBF4-8431-4C9D-8173-CA6DEC1104F0",
              "versionEndExcluding": "va40g_hf01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in syngo Dynamics (All versions \u003c VA40G HF01). An unauthenticated Server-Side Request Forgery (SSRF) vulnerability was identified in one of the web services exposed on the syngo Dynamics application that could allow for the leaking of NTLM credentials as well as local service enumeration."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en syngo Dynamics (todas las versiones \u0026lt; VA40G HF01). Se identific\u00f3 una vulnerabilidad de falsificaci\u00f3n de solicitudes del lado del servidor (SSRF) no autenticada en uno de los servicios web expuestos en la aplicaci\u00f3n syngo Dynamics que podr\u00eda permitir la filtraci\u00f3n de credenciales NTLM, as\u00ed como la enumeraci\u00f3n de servicios locales."
    }
  ],
  "id": "CVE-2022-42894",
  "lastModified": "2025-04-30T15:15:57.507",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2022-11-17T17:15:13.433",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-918"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-918"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-11-17 17:15
Modified
2025-04-29 20:15
Summary
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper write access control that could allow to write data in any folder accessible to the account assigned to the website’s application pool.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:syngo_dynamics_cardiovascular_imaging_and_information_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2F3FBF4-8431-4C9D-8173-CA6DEC1104F0",
              "versionEndExcluding": "va40g_hf01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in syngo Dynamics (All versions \u003c VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper write access control that could allow to write data in any folder accessible to the account assigned to the website\u2019s application pool."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en syngo Dynamics (todas las versiones \u0026lt; VA40G HF01). El servidor de aplicaciones syngo Dynamics aloja un servicio web mediante una operaci\u00f3n con control de acceso de escritura inadecuado que podr\u00eda permitir escribir datos en cualquier carpeta accesible a la cuenta asignada al grupo de aplicaciones del sitio web."
    }
  ],
  "id": "CVE-2022-42734",
  "lastModified": "2025-04-29T20:15:21.683",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2022-11-17T17:15:12.370",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-73"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-610"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-11-17 17:15
Modified
2025-04-29 21:15
Summary
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper read access control that could allow files to be retrieved from any folder accessible to the account assigned to the website’s application pool.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:syngo_dynamics_cardiovascular_imaging_and_information_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2F3FBF4-8431-4C9D-8173-CA6DEC1104F0",
              "versionEndExcluding": "va40g_hf01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in syngo Dynamics (All versions \u003c VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper read access control that could allow files to be retrieved from any folder accessible to the account assigned to the website\u2019s application pool."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en syngo Dynamics (todas las versiones \u0026lt; VA40G HF01). El servidor de aplicaciones syngo Dynamics aloja un servicio web mediante una operaci\u00f3n con control de acceso de lectura inadecuado que podr\u00eda permitir recuperar archivos desde cualquier carpeta accesible a la cuenta asignada al grupo de aplicaciones del sitio web."
    }
  ],
  "id": "CVE-2022-42732",
  "lastModified": "2025-04-29T21:15:49.620",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2022-11-17T17:15:11.673",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-73"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-610"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-11-17 17:15
Modified
2025-04-29 20:15
Summary
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper write access control that could allow to write data in any folder accessible to the account assigned to the website’s application pool.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:syngo_dynamics_cardiovascular_imaging_and_information_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2F3FBF4-8431-4C9D-8173-CA6DEC1104F0",
              "versionEndExcluding": "va40g_hf01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in syngo Dynamics (All versions \u003c VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper write access control that could allow to write data in any folder accessible to the account assigned to the website\u2019s application pool."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en syngo Dynamics (todas las versiones \u0026lt; VA40G HF01). El servidor de aplicaciones syngo Dynamics aloja un servicio web mediante una operaci\u00f3n con control de acceso de escritura inadecuado que podr\u00eda permitir escribir datos en cualquier carpeta accesible a la cuenta asignada al grupo de aplicaciones del sitio web."
    }
  ],
  "id": "CVE-2022-42891",
  "lastModified": "2025-04-29T20:15:21.857",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2022-11-17T17:15:12.577",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-741697"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-73"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-610"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}