Vulnerabilites related to siemens - scalance_x-300eec
cve-2014-8478
Vulnerability from cvelistv5
Published
2015-01-21 17:00
Modified
2024-08-06 13:18
Severity ?
Summary
The web server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote attackers to cause a denial of service (reboot) via malformed HTTP requests.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-06T13:18:48.325Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_refsource_CONFIRM",
                     "x_transferred",
                  ],
                  url: "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf",
               },
               {
                  tags: [
                     "x_refsource_CONFIRM",
                     "x_transferred",
                  ],
                  url: "https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         datePublic: "2015-01-19T00:00:00",
         descriptions: [
            {
               lang: "en",
               value: "The web server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote attackers to cause a denial of service (reboot) via malformed HTTP requests.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2020-02-10T14:06:14",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               tags: [
                  "x_refsource_CONFIRM",
               ],
               url: "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf",
            },
            {
               tags: [
                  "x_refsource_CONFIRM",
               ],
               url: "https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf",
            },
         ],
         x_legacyV4Record: {
            CVE_data_meta: {
               ASSIGNER: "cve@mitre.org",
               ID: "CVE-2014-8478",
               STATE: "PUBLIC",
            },
            affects: {
               vendor: {
                  vendor_data: [
                     {
                        product: {
                           product_data: [
                              {
                                 product_name: "n/a",
                                 version: {
                                    version_data: [
                                       {
                                          version_value: "n/a",
                                       },
                                    ],
                                 },
                              },
                           ],
                        },
                        vendor_name: "n/a",
                     },
                  ],
               },
            },
            data_format: "MITRE",
            data_type: "CVE",
            data_version: "4.0",
            description: {
               description_data: [
                  {
                     lang: "eng",
                     value: "The web server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote attackers to cause a denial of service (reboot) via malformed HTTP requests.",
                  },
               ],
            },
            problemtype: {
               problemtype_data: [
                  {
                     description: [
                        {
                           lang: "eng",
                           value: "n/a",
                        },
                     ],
                  },
               ],
            },
            references: {
               reference_data: [
                  {
                     name: "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf",
                     refsource: "CONFIRM",
                     url: "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf",
                  },
                  {
                     name: "https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf",
                     refsource: "CONFIRM",
                     url: "https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf",
                  },
               ],
            },
         },
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2014-8478",
      datePublished: "2015-01-21T17:00:00",
      dateReserved: "2014-10-24T00:00:00",
      dateUpdated: "2024-08-06T13:18:48.325Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2014-8479
Vulnerability from cvelistv5
Published
2015-01-21 17:00
Modified
2024-08-06 13:18
Severity ?
Summary
The FTP server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote authenticated users to cause a denial of service (reboot) via crafted FTP packets.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-06T13:18:48.283Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_refsource_CONFIRM",
                     "x_transferred",
                  ],
                  url: "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf",
               },
               {
                  tags: [
                     "x_refsource_CONFIRM",
                     "x_transferred",
                  ],
                  url: "https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         datePublic: "2015-01-19T00:00:00",
         descriptions: [
            {
               lang: "en",
               value: "The FTP server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote authenticated users to cause a denial of service (reboot) via crafted FTP packets.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2020-02-10T14:06:13",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               tags: [
                  "x_refsource_CONFIRM",
               ],
               url: "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf",
            },
            {
               tags: [
                  "x_refsource_CONFIRM",
               ],
               url: "https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf",
            },
         ],
         x_legacyV4Record: {
            CVE_data_meta: {
               ASSIGNER: "cve@mitre.org",
               ID: "CVE-2014-8479",
               STATE: "PUBLIC",
            },
            affects: {
               vendor: {
                  vendor_data: [
                     {
                        product: {
                           product_data: [
                              {
                                 product_name: "n/a",
                                 version: {
                                    version_data: [
                                       {
                                          version_value: "n/a",
                                       },
                                    ],
                                 },
                              },
                           ],
                        },
                        vendor_name: "n/a",
                     },
                  ],
               },
            },
            data_format: "MITRE",
            data_type: "CVE",
            data_version: "4.0",
            description: {
               description_data: [
                  {
                     lang: "eng",
                     value: "The FTP server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote authenticated users to cause a denial of service (reboot) via crafted FTP packets.",
                  },
               ],
            },
            problemtype: {
               problemtype_data: [
                  {
                     description: [
                        {
                           lang: "eng",
                           value: "n/a",
                        },
                     ],
                  },
               ],
            },
            references: {
               reference_data: [
                  {
                     name: "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf",
                     refsource: "CONFIRM",
                     url: "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf",
                  },
                  {
                     name: "https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf",
                     refsource: "CONFIRM",
                     url: "https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf",
                  },
               ],
            },
         },
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2014-8479",
      datePublished: "2015-01-21T17:00:00",
      dateReserved: "2014-10-24T00:00:00",
      dateUpdated: "2024-08-06T13:18:48.283Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2012-1802
Vulnerability from cvelistv5
Published
2012-04-18 10:00
Modified
2024-08-06 19:08
Severity ?
Summary
Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-06T19:08:38.499Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  name: "81032",
                  tags: [
                     "vdb-entry",
                     "x_refsource_OSVDB",
                     "x_transferred",
                  ],
                  url: "http://osvdb.org/81032",
               },
               {
                  tags: [
                     "x_refsource_MISC",
                     "x_transferred",
                  ],
                  url: "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-04.pdf",
               },
               {
                  tags: [
                     "x_refsource_CONFIRM",
                     "x_transferred",
                  ],
                  url: "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-130874.pdf",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         datePublic: "2012-04-11T00:00:00",
         descriptions: [
            {
               lang: "en",
               value: "Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2012-11-20T10:00:00",
            orgId: "37e5125f-f79b-445b-8fad-9564f167944b",
            shortName: "certcc",
         },
         references: [
            {
               name: "81032",
               tags: [
                  "vdb-entry",
                  "x_refsource_OSVDB",
               ],
               url: "http://osvdb.org/81032",
            },
            {
               tags: [
                  "x_refsource_MISC",
               ],
               url: "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-04.pdf",
            },
            {
               tags: [
                  "x_refsource_CONFIRM",
               ],
               url: "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-130874.pdf",
            },
         ],
         x_legacyV4Record: {
            CVE_data_meta: {
               ASSIGNER: "cert@cert.org",
               ID: "CVE-2012-1802",
               STATE: "PUBLIC",
            },
            affects: {
               vendor: {
                  vendor_data: [
                     {
                        product: {
                           product_data: [
                              {
                                 product_name: "n/a",
                                 version: {
                                    version_data: [
                                       {
                                          version_value: "n/a",
                                       },
                                    ],
                                 },
                              },
                           ],
                        },
                        vendor_name: "n/a",
                     },
                  ],
               },
            },
            data_format: "MITRE",
            data_type: "CVE",
            data_version: "4.0",
            description: {
               description_data: [
                  {
                     lang: "eng",
                     value: "Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL.",
                  },
               ],
            },
            problemtype: {
               problemtype_data: [
                  {
                     description: [
                        {
                           lang: "eng",
                           value: "n/a",
                        },
                     ],
                  },
               ],
            },
            references: {
               reference_data: [
                  {
                     name: "81032",
                     refsource: "OSVDB",
                     url: "http://osvdb.org/81032",
                  },
                  {
                     name: "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-04.pdf",
                     refsource: "MISC",
                     url: "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-04.pdf",
                  },
                  {
                     name: "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-130874.pdf",
                     refsource: "CONFIRM",
                     url: "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-130874.pdf",
                  },
               ],
            },
         },
      },
   },
   cveMetadata: {
      assignerOrgId: "37e5125f-f79b-445b-8fad-9564f167944b",
      assignerShortName: "certcc",
      cveId: "CVE-2012-1802",
      datePublished: "2012-04-18T10:00:00",
      dateReserved: "2012-03-21T00:00:00",
      dateUpdated: "2024-08-06T19:08:38.499Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

Vulnerability from fkie_nvd
Published
2012-04-18 10:33
Modified
2024-11-21 01:37
Severity ?
Summary
Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL.



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_x414-3e_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "FB47C02A-0FD8-47A2-93F8-310A5E05E19F",
                     versionEndIncluding: "3.7.0",
                     vulnerable: true,
                  },
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_x414-3e_firmware:1.2.2:*:*:*:*:*:*:*",
                     matchCriteriaId: "6212D6C3-A68D-41BA-929A-943A157B3BA7",
                     vulnerable: true,
                  },
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_x414-3e_firmware:2.1.1:*:*:*:*:*:*:*",
                     matchCriteriaId: "56338A9A-C59D-47D3-9AB4-18C53A75EDD5",
                     vulnerable: true,
                  },
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_x414-3e_firmware:2.2.0:*:*:*:*:*:*:*",
                     matchCriteriaId: "801D7741-8EBB-4A68-A77C-E26C304EB988",
                     vulnerable: true,
                  },
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_x414-3e_firmware:2.3.2:*:*:*:*:*:*:*",
                     matchCriteriaId: "EF4AB664-29DD-46F0-B136-8BD458430BD4",
                     vulnerable: true,
                  },
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_x414-3e_firmware:2.3.3:*:*:*:*:*:*:*",
                     matchCriteriaId: "DB8720F3-21D3-40C1-98A8-90E2EF6BBA52",
                     vulnerable: true,
                  },
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_x414-3e_firmware:3.0.0:*:*:*:*:*:*:*",
                     matchCriteriaId: "FFF99DC1-34B7-4AAA-BC33-5763B56EEA1B",
                     vulnerable: true,
                  },
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_x414-3e_firmware:3.0.2:*:*:*:*:*:*:*",
                     matchCriteriaId: "629D65C2-0D61-48BD-9C73-7794AC061756",
                     vulnerable: true,
                  },
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_x414-3e_firmware:3.3.0:*:*:*:*:*:*:*",
                     matchCriteriaId: "DDD5708A-0105-4129-B5A6-DAF0247ABE1F",
                     vulnerable: true,
                  },
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_x414-3e_firmware:3.4.0:*:*:*:*:*:*:*",
                     matchCriteriaId: "B349A4F6-1FB0-433B-B512-883E580CFB27",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x414-3e:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6645288F-F688-442A-8C56-17536BFAD4BE",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "EC42F509-F58D-4A65-9C31-26F0C7319076",
                     versionEndIncluding: "3.7.0",
                     vulnerable: true,
                  },
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_x308-2m_firmware:3.1.1:*:*:*:*:*:*:*",
                     matchCriteriaId: "4020E0F4-E92A-442D-A703-CA8840B8D944",
                     vulnerable: true,
                  },
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_x308-2m_firmware:3.5.0:*:*:*:*:*:*:*",
                     matchCriteriaId: "58E635A6-1AFF-4A34-87F3-F68571032448",
                     vulnerable: true,
                  },
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_x308-2m_firmware:3.5.2:*:*:*:*:*:*:*",
                     matchCriteriaId: "BB1B5735-D3C0-445C-B7D5-A3099D1CE152",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "AC54911E-C432-48FA-9551-9644422FFE14",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_x-300eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "6F13D012-86FA-4A41-8D18-94942A270DAA",
                     versionEndIncluding: "3.7.0",
                     vulnerable: true,
                  },
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_x-300eec_firmware:3.5.0:*:*:*:*:*:*:*",
                     matchCriteriaId: "BB16E154-1E59-438F-9895-47260FDD7230",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x-300eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "F2F32466-A411-4D69-864A-4434D3D5DB54",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_xr-300_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "FF530C3C-A126-4F6A-8010-E93352800598",
                     versionEndIncluding: "3.7.0",
                     vulnerable: true,
                  },
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_xr-300_firmware:3.1.1:*:*:*:*:*:*:*",
                     matchCriteriaId: "AE3F5ED9-F357-430C-B277-B7EC0715A391",
                     vulnerable: true,
                  },
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_xr-300_firmware:3.5.0:*:*:*:*:*:*:*",
                     matchCriteriaId: "61FF9CF2-14CD-49BF-AC0B-0D2E0EDCF79F",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr-300:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "889CF2C0-EE6C-447F-85F1-005730EAD232",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_x-300_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "F2000A16-E8A2-4E8E-A90F-4E0F62F3993C",
                     versionEndIncluding: "3.7.0",
                     vulnerable: true,
                  },
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_x-300_firmware:2.2.0:*:*:*:*:*:*:*",
                     matchCriteriaId: "AF93BD72-2893-436D-A514-3C463C1AA428",
                     vulnerable: true,
                  },
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_x-300_firmware:2.3.1:*:*:*:*:*:*:*",
                     matchCriteriaId: "59323828-6A3A-48CD-B98C-64CD65829471",
                     vulnerable: true,
                  },
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_x-300_firmware:3.0.0:*:*:*:*:*:*:*",
                     matchCriteriaId: "C8C53B2B-BFFC-47D1-B935-FF85F5A4D3F1",
                     vulnerable: true,
                  },
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_x-300_firmware:3.3.1:*:*:*:*:*:*:*",
                     matchCriteriaId: "054C0618-5CA9-43E4-A557-0064B8BB5B63",
                     vulnerable: true,
                  },
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_x-300_firmware:3.5.0:*:*:*:*:*:*:*",
                     matchCriteriaId: "6D5DF242-8FD0-467C-84D1-5207CC15D2D2",
                     vulnerable: true,
                  },
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_x-300_firmware:3.5.1:*:*:*:*:*:*:*",
                     matchCriteriaId: "B16E873A-5D79-43B8-BB64-66B8079CFCC4",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x-300:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "B2D0AB50-6F0B-4232-8C8E-1647410D362D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL.",
      },
      {
         lang: "es",
         value: "Desbordamiento de búfer en el servidor web integrado en el conmutador ethernet industrial Siemens Scalance X X414-3E antes de v3.7.1, X308-2M antes de v3.7.2, X-300EEC antes de v3.7.2, XR-300 antes de v3.7.2, y X-300 antes de v3.7.2 permite a atacantes remotos causar una denegación de servicio (reinicio del dispositivo) o posiblemente ejecutar código arbitrario a través de una dirección URL incorrecta.",
      },
   ],
   id: "CVE-2012-1802",
   lastModified: "2024-11-21T01:37:48.693",
   metrics: {
      cvssMetricV2: [
         {
            acInsufInfo: false,
            baseSeverity: "HIGH",
            cvssData: {
               accessComplexity: "LOW",
               accessVector: "NETWORK",
               authentication: "NONE",
               availabilityImpact: "COMPLETE",
               baseScore: 7.8,
               confidentialityImpact: "NONE",
               integrityImpact: "NONE",
               vectorString: "AV:N/AC:L/Au:N/C:N/I:N/A:C",
               version: "2.0",
            },
            exploitabilityScore: 10,
            impactScore: 6.9,
            obtainAllPrivilege: false,
            obtainOtherPrivilege: false,
            obtainUserPrivilege: false,
            source: "nvd@nist.gov",
            type: "Primary",
            userInteractionRequired: false,
         },
      ],
   },
   published: "2012-04-18T10:33:35.450",
   references: [
      {
         source: "cret@cert.org",
         url: "http://osvdb.org/81032",
      },
      {
         source: "cret@cert.org",
         tags: [
            "Vendor Advisory",
         ],
         url: "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-130874.pdf",
      },
      {
         source: "cret@cert.org",
         tags: [
            "US Government Resource",
         ],
         url: "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-04.pdf",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         url: "http://osvdb.org/81032",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Vendor Advisory",
         ],
         url: "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-130874.pdf",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "US Government Resource",
         ],
         url: "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-04.pdf",
      },
   ],
   sourceIdentifier: "cret@cert.org",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-119",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2015-01-21 17:59
Modified
2024-11-21 02:19
Severity ?
Summary
The FTP server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote authenticated users to cause a denial of service (reboot) via crafted FTP packets.



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_x-408_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "C9B53C2F-04E1-4EE7-A052-2F141179DB8E",
                     versionEndIncluding: "3.9.3",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x-408:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "ED518CFA-AFD5-4ACA-ACFD-C7E527EC4E04",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_x-300_series_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "75396A33-A4A6-46D9-A6CF-11BB86221B60",
                     versionEndIncluding: "3.9.3",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x-300:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "B2D0AB50-6F0B-4232-8C8E-1647410D362D",
                     vulnerable: false,
                  },
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x-300eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "F2F32466-A411-4D69-864A-4434D3D5DB54",
                     vulnerable: false,
                  },
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x-300poe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "FBE436EC-0C06-4635-BF0A-24A01A3C94C5",
                     vulnerable: false,
                  },
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr-300:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "889CF2C0-EE6C-447F-85F1-005730EAD232",
                     vulnerable: false,
                  },
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr-300eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6FF41E9F-4627-49EE-BCF1-08B5AADE964A",
                     vulnerable: false,
                  },
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr-300poe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "CC118867-1A6C-4C3B-AD75-5D24551DB0BC",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "The FTP server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote authenticated users to cause a denial of service (reboot) via crafted FTP packets.",
      },
      {
         lang: "es",
         value: "El servidor FTP Siemens en los switches SCALANCE X-300 con firmware anterior a 4.0 y los switches SCALANCE X 408 con firmware anterior a 4.0 permite a usuarios remotos autenticados causar una denegación de servicio (reinicio) a través de paquetes FTP modificados.",
      },
   ],
   id: "CVE-2014-8479",
   lastModified: "2024-11-21T02:19:08.900",
   metrics: {
      cvssMetricV2: [
         {
            acInsufInfo: false,
            baseSeverity: "MEDIUM",
            cvssData: {
               accessComplexity: "LOW",
               accessVector: "NETWORK",
               authentication: "SINGLE",
               availabilityImpact: "COMPLETE",
               baseScore: 6.8,
               confidentialityImpact: "NONE",
               integrityImpact: "NONE",
               vectorString: "AV:N/AC:L/Au:S/C:N/I:N/A:C",
               version: "2.0",
            },
            exploitabilityScore: 8,
            impactScore: 6.9,
            obtainAllPrivilege: false,
            obtainOtherPrivilege: false,
            obtainUserPrivilege: false,
            source: "nvd@nist.gov",
            type: "Primary",
            userInteractionRequired: false,
         },
      ],
   },
   published: "2015-01-21T17:59:01.323",
   references: [
      {
         source: "cve@mitre.org",
         tags: [
            "Vendor Advisory",
         ],
         url: "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf",
      },
      {
         source: "cve@mitre.org",
         url: "https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Vendor Advisory",
         ],
         url: "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         url: "https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf",
      },
   ],
   sourceIdentifier: "cve@mitre.org",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-20",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2015-01-21 17:59
Modified
2024-11-21 02:19
Severity ?
Summary
The web server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote attackers to cause a denial of service (reboot) via malformed HTTP requests.



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_x-300_series_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "75396A33-A4A6-46D9-A6CF-11BB86221B60",
                     versionEndIncluding: "3.9.3",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x-300:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "B2D0AB50-6F0B-4232-8C8E-1647410D362D",
                     vulnerable: false,
                  },
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x-300eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "F2F32466-A411-4D69-864A-4434D3D5DB54",
                     vulnerable: false,
                  },
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x-300poe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "FBE436EC-0C06-4635-BF0A-24A01A3C94C5",
                     vulnerable: false,
                  },
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr-300:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "889CF2C0-EE6C-447F-85F1-005730EAD232",
                     vulnerable: false,
                  },
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr-300eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6FF41E9F-4627-49EE-BCF1-08B5AADE964A",
                     vulnerable: false,
                  },
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr-300poe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "CC118867-1A6C-4C3B-AD75-5D24551DB0BC",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:a:siemens:scalance_x-408_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "C9B53C2F-04E1-4EE7-A052-2F141179DB8E",
                     versionEndIncluding: "3.9.3",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x-408:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "ED518CFA-AFD5-4ACA-ACFD-C7E527EC4E04",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "The web server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote attackers to cause a denial of service (reboot) via malformed HTTP requests.",
      },
      {
         lang: "es",
         value: "El servidor web en los switches SCALANCE X-300 con firmware anteriores a 4.0 y los switches SCALANCE X 408 con firmware anterior a 4.0 permite a atacantes remotos causar una denegación de servicio (reinicio) a través de peticiones HTTP mal formadas.",
      },
   ],
   id: "CVE-2014-8478",
   lastModified: "2024-11-21T02:19:08.760",
   metrics: {
      cvssMetricV2: [
         {
            acInsufInfo: false,
            baseSeverity: "HIGH",
            cvssData: {
               accessComplexity: "LOW",
               accessVector: "NETWORK",
               authentication: "NONE",
               availabilityImpact: "COMPLETE",
               baseScore: 7.8,
               confidentialityImpact: "NONE",
               integrityImpact: "NONE",
               vectorString: "AV:N/AC:L/Au:N/C:N/I:N/A:C",
               version: "2.0",
            },
            exploitabilityScore: 10,
            impactScore: 6.9,
            obtainAllPrivilege: false,
            obtainOtherPrivilege: false,
            obtainUserPrivilege: false,
            source: "nvd@nist.gov",
            type: "Primary",
            userInteractionRequired: false,
         },
      ],
   },
   published: "2015-01-21T17:59:00.060",
   references: [
      {
         source: "cve@mitre.org",
         tags: [
            "Vendor Advisory",
         ],
         url: "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf",
      },
      {
         source: "cve@mitre.org",
         url: "https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Vendor Advisory",
         ],
         url: "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         url: "https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf",
      },
   ],
   sourceIdentifier: "cve@mitre.org",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-22",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
   ],
}