Vulnerabilites related to echarge - salia_plcc
Vulnerability from fkie_nvd
Published
2024-11-24 23:15
Modified
2024-12-04 17:43
Severity ?
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in hardy-barth cph2_echarge_firmware allows OS Command Injection.This issue affects cph2_echarge_firmware: through 2.0.4.
References
▼ | URL | Tags | |
---|---|---|---|
research@onekey.com | https://www.onekey.com/resource/critical-vulnerabilities-in-ev-charging-stations-analysis-of-echarge-controllers | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
echarge | salia_plcc_firmware | * | |
echarge | salia_plcc | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:echarge:salia_plcc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "68BE2BFC-8664-4D95-AB52-0724D268B9AA", "versionEndIncluding": "2.0.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:echarge:salia_plcc:-:*:*:*:*:*:*:*", "matchCriteriaId": "7ABECA31-3F68-4CAC-991F-7EC594A2A779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in hardy-barth cph2_echarge_firmware allows OS Command Injection.This issue affects cph2_echarge_firmware: through 2.0.4." }, { "lang": "es", "value": "La vulnerabilidad de neutralizaci\u00f3n incorrecta de elementos especiales utilizados en un comando (\u0027Inyecci\u00f3n de comando\u0027) en hardy-barth cph2_echarge_firmware permite la inyecci\u00f3n de comandos del sistema operativo. Este problema afecta a cph2_echarge_firmware: hasta 2.0.4." } ], "id": "CVE-2024-11665", "lastModified": "2024-12-04T17:43:55.183", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "research@onekey.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-11-24T23:15:03.903", "references": [ { "source": "research@onekey.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://www.onekey.com/resource/critical-vulnerabilities-in-ev-charging-stations-analysis-of-echarge-controllers" } ], "sourceIdentifier": "research@onekey.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "research@onekey.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-11-24 23:15
Modified
2024-12-03 15:40
Severity ?
9.0 (Critical) - CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Affected devices beacon to eCharge cloud infrastructure asking if there are any command they should run. This communication is established over an insecure channel since peer verification is disabled everywhere. Therefore, remote unauthenticated users suitably positioned on the network between an EV charger controller and eCharge infrastructure can execute arbitrary commands with elevated privileges on affected devices.
This issue affects cph2_echarge_firmware: through 2.0.4.
References
▼ | URL | Tags | |
---|---|---|---|
research@onekey.com | https://www.onekey.com/resource/critical-vulnerabilities-in-ev-charging-stations-analysis-of-echarge-controllers | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
echarge | salia_plcc_firmware | * | |
echarge | salia_plcc | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:echarge:salia_plcc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "68BE2BFC-8664-4D95-AB52-0724D268B9AA", "versionEndIncluding": "2.0.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:echarge:salia_plcc:-:*:*:*:*:*:*:*", "matchCriteriaId": "7ABECA31-3F68-4CAC-991F-7EC594A2A779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Affected devices beacon to eCharge cloud infrastructure asking if there are any command they should run. This communication is established over an insecure channel since peer verification is disabled everywhere. Therefore, remote unauthenticated users\u00a0 suitably positioned on the network between an EV charger controller and eCharge infrastructure can execute arbitrary commands with elevated privileges on affected devices.\n\nThis issue affects cph2_echarge_firmware: through 2.0.4." }, { "lang": "es", "value": "Los dispositivos afectados env\u00edan se\u00f1ales a la infraestructura en la nube de eCharge para preguntar si hay alg\u00fan comando que deban ejecutar. Esta comunicaci\u00f3n se establece a trav\u00e9s de un canal inseguro, ya que la verificaci\u00f3n entre pares est\u00e1 deshabilitada en todas partes. Por lo tanto, los usuarios remotos no autenticados ubicados adecuadamente en la red entre un controlador de cargador de veh\u00edculos el\u00e9ctricos y la infraestructura de eCharge pueden ejecutar comandos arbitrarios con privilegios elevados en los dispositivos afectados. Este problema afecta a cph2_echarge_firmware: hasta la versi\u00f3n 2.0.4." } ], "id": "CVE-2024-11666", "lastModified": "2024-12-03T15:40:14.907", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.0, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.2, "impactScore": 6.0, "source": "research@onekey.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-11-24T23:15:04.030", "references": [ { "source": "research@onekey.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://www.onekey.com/resource/critical-vulnerabilities-in-ev-charging-stations-analysis-of-echarge-controllers" } ], "sourceIdentifier": "research@onekey.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-345" } ], "source": "research@onekey.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-345" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
CVE-2024-11665 (GCVE-0-2024-11665)
Vulnerability from cvelistv5
Published
2024-11-24 22:32
Modified
2024-11-25 01:30
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Summary
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in hardy-barth cph2_echarge_firmware allows OS Command Injection.This issue affects cph2_echarge_firmware: through 2.0.4.
References
▼ | URL | Tags |
---|---|---|
https://www.onekey.com/resource/critical-vulnerabilities-in-ev-charging-stations-analysis-of-echarge-controllers | third-party-advisory |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
hardy-barth | cph2_echarge_firmware |
Version: 0 ≤ 2.0.4 |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:hardy-barth:cph2_echarge_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "cph2_echarge_firmware", "vendor": "hardy-barth", "versions": [ { "lessThanOrEqual": "2.0.4", "status": "affected", "version": "0", "versionType": "semver" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-11665", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-25T01:30:19.320887Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-25T01:30:24.409Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "cph2_echarge_firmware", "vendor": "hardy-barth", "versions": [ { "lessThanOrEqual": "2.0.4", "status": "affected", "version": "0", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Quentin Kaiser from ONEKEY Research Labs" } ], "datePublic": "2024-11-24T07:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in hardy-barth cph2_echarge_firmware allows OS Command Injection.\u003cp\u003eThis issue affects cph2_echarge_firmware: through 2.0.4.\u003c/p\u003e" } ], "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in hardy-barth cph2_echarge_firmware allows OS Command Injection.This issue affects cph2_echarge_firmware: through 2.0.4." } ], "impacts": [ { "capecId": "CAPEC-88", "descriptions": [ { "lang": "en", "value": "CAPEC-88 OS Command Injection" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-77", "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-24T23:18:51.581Z", "orgId": "2d533b80-6e4a-4e20-93e2-171235122846", "shortName": "ONEKEY" }, "references": [ { "tags": [ "third-party-advisory" ], "url": "https://www.onekey.com/resource/critical-vulnerabilities-in-ev-charging-stations-analysis-of-echarge-controllers" } ], "source": { "discovery": "UNKNOWN" }, "title": "Unauthenticated Remote Command Injection", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "2d533b80-6e4a-4e20-93e2-171235122846", "assignerShortName": "ONEKEY", "cveId": "CVE-2024-11665", "datePublished": "2024-11-24T22:32:43.427Z", "dateReserved": "2024-11-24T22:27:15.904Z", "dateUpdated": "2024-11-25T01:30:24.409Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-11666 (GCVE-0-2024-11666)
Vulnerability from cvelistv5
Published
2024-11-24 22:36
Modified
2024-11-25 01:28
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-345 - Insufficient Verification of Data Authenticity
Summary
Affected devices beacon to eCharge cloud infrastructure asking if there are any command they should run. This communication is established over an insecure channel since peer verification is disabled everywhere. Therefore, remote unauthenticated users suitably positioned on the network between an EV charger controller and eCharge infrastructure can execute arbitrary commands with elevated privileges on affected devices.
This issue affects cph2_echarge_firmware: through 2.0.4.
References
▼ | URL | Tags |
---|---|---|
https://www.onekey.com/resource/critical-vulnerabilities-in-ev-charging-stations-analysis-of-echarge-controllers | third-party-advisory |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
hardy-barth | cph2_echarge_firmware |
Version: 0 ≤ 2.0.4 |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:hardy-barth:cph2_echarge_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "cph2_echarge_firmware", "vendor": "hardy-barth", "versions": [ { "lessThanOrEqual": "2.0.4", "status": "affected", "version": "0", "versionType": "semver" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-11666", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-25T01:27:53.302041Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-25T01:28:57.027Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "cph2_echarge_firmware", "vendor": "hardy-barth", "versions": [ { "lessThanOrEqual": "2.0.4", "status": "affected", "version": "0", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Quentin Kaiser from ONEKEY Research Labs" } ], "datePublic": "2024-11-24T07:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Affected devices beacon to eCharge cloud infrastructure asking if there are any command they should run. This communication is established over an insecure channel since peer verification is disabled everywhere. Therefore, remote unauthenticated users\u0026nbsp; suitably positioned on the network between an EV charger controller and eCharge infrastructure can execute arbitrary commands with elevated privileges on affected devices.\u003cbr\u003e\u003cbr\u003e\u003cp\u003eThis issue affects cph2_echarge_firmware: through 2.0.4.\u003c/p\u003e" } ], "value": "Affected devices beacon to eCharge cloud infrastructure asking if there are any command they should run. This communication is established over an insecure channel since peer verification is disabled everywhere. Therefore, remote unauthenticated users\u00a0 suitably positioned on the network between an EV charger controller and eCharge infrastructure can execute arbitrary commands with elevated privileges on affected devices.\n\nThis issue affects cph2_echarge_firmware: through 2.0.4." } ], "impacts": [ { "capecId": "CAPEC-88", "descriptions": [ { "lang": "en", "value": "CAPEC-88 OS Command Injection" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-345", "description": "CWE-345 Insufficient Verification of Data Authenticity", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-24T23:19:03.796Z", "orgId": "2d533b80-6e4a-4e20-93e2-171235122846", "shortName": "ONEKEY" }, "references": [ { "tags": [ "third-party-advisory" ], "url": "https://www.onekey.com/resource/critical-vulnerabilities-in-ev-charging-stations-analysis-of-echarge-controllers" } ], "source": { "discovery": "UNKNOWN" }, "title": "Unauthenticated Remote Command Injection in eCharge Salia PLCC", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "2d533b80-6e4a-4e20-93e2-171235122846", "assignerShortName": "ONEKEY", "cveId": "CVE-2024-11666", "datePublished": "2024-11-24T22:36:59.989Z", "dateReserved": "2024-11-24T22:27:19.421Z", "dateUpdated": "2024-11-25T01:28:57.027Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }