Search criteria

21 vulnerabilities found for rx_1500_firmware by intelbras

FKIE_CVE-2025-26065

Vulnerability from fkie_nvd - Published: 2025-08-04 15:15 - Updated: 2025-11-03 20:18
Summary
A cross-site scripting (XSS) vulnerability in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows attackers to execute arbitrary web scripts or HTML via injecting a crafted payload into the name of a visiting Wi-Fi network.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intelbras:rx_1500_firmware:2.2.9:*:*:*:*:*:*:*",
              "matchCriteriaId": "ECB8C40B-084E-4858-AA0C-966E3D86B100",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intelbras:rx_1500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B3E00F0-4F8F-4A2F-A553-74B0C682EF3C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intelbras:rx_3000_firmware:1.0.11:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E2495F3-D96B-475D-BC50-F75324036A66",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intelbras:rx_3000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A807025F-C981-4DED-9F75-A2F02E63416E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A cross-site scripting (XSS) vulnerability in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows attackers to execute arbitrary web scripts or HTML via injecting a crafted payload into the name of a visiting Wi-Fi network."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de cross-site scripting (XSS) en Intelbras RX1500 v2.2.9 y RX3000 v1.0.11 permite a los atacantes ejecutar scripts web o HTML arbitrarios mediante la inyecci\u00f3n de un payload manipulado en el nombre de una red Wi-Fi visitante."
    }
  ],
  "id": "CVE-2025-26065",
  "lastModified": "2025-11-03T20:18:00.833",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.4,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-08-04T15:15:31.067",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Release Notes"
      ],
      "url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX1500.html"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Release Notes"
      ],
      "url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX3000.html"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "https://seclists.org/fulldisclosure/2025/Jul/26"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://seclists.org/fulldisclosure/2025/Jul/26"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2025-26062

Vulnerability from fkie_nvd - Published: 2025-07-31 19:15 - Updated: 2025-11-03 20:18
Severity ?
Summary
An access control issue in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows unauthenticated attackers to access the router's settings file and obtain potentially sensitive information from the current settings.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intelbras:rx_1500_firmware:2.2.9:*:*:*:*:*:*:*",
              "matchCriteriaId": "ECB8C40B-084E-4858-AA0C-966E3D86B100",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intelbras:rx_1500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B3E00F0-4F8F-4A2F-A553-74B0C682EF3C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intelbras:rx_3000_firmware:1.0.11:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E2495F3-D96B-475D-BC50-F75324036A66",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intelbras:rx_3000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A807025F-C981-4DED-9F75-A2F02E63416E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An access control issue in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows unauthenticated attackers to access the router\u0027s settings file and obtain potentially sensitive information from the current settings."
    },
    {
      "lang": "es",
      "value": "Un problema de control de acceso en Intelbras RX1500 v2.2.9 y RX3000 v1.0.11 permite a atacantes no autenticados acceder al archivo de configuraci\u00f3n del enrutador y obtener informaci\u00f3n potencialmente confidencial de la configuraci\u00f3n actual."
    }
  ],
  "id": "CVE-2025-26062",
  "lastModified": "2025-11-03T20:18:00.380",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-07-31T19:15:28.610",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Release Notes"
      ],
      "url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX1500.html"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Release Notes"
      ],
      "url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX3000.html"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "https://seclists.org/fulldisclosure/2025/Jul/14"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://seclists.org/fulldisclosure/2025/Jul/14"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://seclists.org/fulldisclosure/2025/Jul/26"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-284"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2025-26064

Vulnerability from fkie_nvd - Published: 2025-07-31 19:15 - Updated: 2025-11-03 20:18
Summary
A cross-site scripting (XSS) vulnerability in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows attackers to execute arbitrary web scripts or HTML via injecting a crafted payload into the name of a connnected device.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intelbras:rx_1500_firmware:2.2.9:*:*:*:*:*:*:*",
              "matchCriteriaId": "ECB8C40B-084E-4858-AA0C-966E3D86B100",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intelbras:rx_1500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B3E00F0-4F8F-4A2F-A553-74B0C682EF3C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intelbras:rx_3000_firmware:1.0.11:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E2495F3-D96B-475D-BC50-F75324036A66",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intelbras:rx_3000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A807025F-C981-4DED-9F75-A2F02E63416E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A cross-site scripting (XSS) vulnerability in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows attackers to execute arbitrary web scripts or HTML via injecting a crafted payload into the name of a connnected device."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de Cross-site Scripting (XSS) en Intelbras RX1500 v2.2.9 y RX3000 v1.0.11 permite a los atacantes ejecutar scripts web o HTML arbitrarios mediante la inyecci\u00f3n de un payload manipulado en el nombre de un dispositivo conectado."
    }
  ],
  "id": "CVE-2025-26064",
  "lastModified": "2025-11-03T20:18:00.690",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.4,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-07-31T19:15:28.927",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Release Notes"
      ],
      "url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX1500.html"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Release Notes"
      ],
      "url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX3000.html"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "https://seclists.org/fulldisclosure/2025/Jul/14"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://seclists.org/fulldisclosure/2025/Jul/14"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://seclists.org/fulldisclosure/2025/Jul/26"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2025-26063

Vulnerability from fkie_nvd - Published: 2025-07-31 19:15 - Updated: 2025-11-03 20:18
Severity ?
Summary
An issue in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows unauthenticated attackers to execute arbitrary code via injecting a crafted payload into the ESSID name when creating a network.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intelbras:rx_1500_firmware:2.2.9:*:*:*:*:*:*:*",
              "matchCriteriaId": "ECB8C40B-084E-4858-AA0C-966E3D86B100",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intelbras:rx_1500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B3E00F0-4F8F-4A2F-A553-74B0C682EF3C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intelbras:rx_3000_firmware:1.0.11:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E2495F3-D96B-475D-BC50-F75324036A66",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intelbras:rx_3000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A807025F-C981-4DED-9F75-A2F02E63416E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows unauthenticated attackers to execute arbitrary code via injecting a crafted payload into the ESSID name when creating a network."
    },
    {
      "lang": "es",
      "value": "Un problema en Intelbras RX1500 v2.2.9 y RX3000 v1.0.11 permite a atacantes no autenticados ejecutar c\u00f3digo arbitrario mediante la inyecci\u00f3n de un payload manipulado en el nombre ESSID al crear una red."
    }
  ],
  "id": "CVE-2025-26063",
  "lastModified": "2025-11-03T20:18:00.540",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-07-31T19:15:28.773",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Release Notes"
      ],
      "url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX1500.html"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Release Notes"
      ],
      "url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX3000.html"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "https://seclists.org/fulldisclosure/2025/Jul/14"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://seclists.org/fulldisclosure/2025/Jul/14"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://seclists.org/fulldisclosure/2025/Jul/26"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2025-50405

Vulnerability from fkie_nvd - Published: 2025-07-01 15:15 - Updated: 2025-08-20 17:05
Summary
Intelbras RX1500 Router v2.2.17 and before is vulnerable to Incorrect Access Control in the FirmwareUpload function and GetFirmwareValidation function.
Impacted products
Vendor Product Version
intelbras rx_1500_firmware *
intelbras rx_1500 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intelbras:rx_1500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9BDD8A0-7DDA-415A-8291-15920FAAA541",
              "versionEndIncluding": "2.2.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intelbras:rx_1500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B3E00F0-4F8F-4A2F-A553-74B0C682EF3C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Intelbras RX1500 Router v2.2.17 and before is vulnerable to Incorrect Access Control in the FirmwareUpload function and GetFirmwareValidation function."
    },
    {
      "lang": "es",
      "value": "Intelbras RX1500 Router v2.2.17 y anteriores es vulnerable a un control de acceso incorrecto en las funciones FirmwareUpload y GetFirmwareValidation."
    }
  ],
  "id": "CVE-2025-50405",
  "lastModified": "2025-08-20T17:05:29.323",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 2.5,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-07-01T15:15:26.167",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/feiwuxingxie/cve/blob/main/Intelbras/vul02/02.md"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Product"
      ],
      "url": "https://www.intelbras.com/en"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-284"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2025-50404

Vulnerability from fkie_nvd - Published: 2025-07-01 15:15 - Updated: 2025-08-20 17:05
Summary
Intelbras RX1500 Router v2.2.17 and before is vulnerable to Integer Overflow. The websReadEvent function incorrectly uses the int type when processing the "command" field of the http header, causing the array to cross the boundary and overwrite other fields in the array.
Impacted products
Vendor Product Version
intelbras rx_1500_firmware *
intelbras rx_1500 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intelbras:rx_1500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9BDD8A0-7DDA-415A-8291-15920FAAA541",
              "versionEndIncluding": "2.2.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intelbras:rx_1500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B3E00F0-4F8F-4A2F-A553-74B0C682EF3C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Intelbras RX1500 Router v2.2.17 and before is vulnerable to Integer Overflow. The websReadEvent function incorrectly uses the int type when processing the \"command\" field of the http header, causing the array to cross the boundary and overwrite other fields in the array."
    },
    {
      "lang": "es",
      "value": "Intelbras RX1500 Router v2.2.17 y versiones anteriores es vulnerable a desbordamiento de enteros. La funci\u00f3n websReadEvent utiliza incorrectamente el tipo int al procesar el campo \"command\" del encabezado http, lo que provoca que la matriz cruce el l\u00edmite y sobrescriba otros campos de la matriz."
    }
  ],
  "id": "CVE-2025-50404",
  "lastModified": "2025-08-20T17:05:58.403",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 1.4,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-07-01T15:15:26.043",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/feiwuxingxie/cve/blob/main/Intelbras/vul01/01.md"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Product"
      ],
      "url": "https://www.intelbras.com/en"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-190"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2023-6103

Vulnerability from fkie_nvd - Published: 2023-11-13 18:15 - Updated: 2024-11-21 08:43
Summary
A vulnerability has been found in Intelbras RX 1500 1.1.9 and classified as problematic. Affected by this vulnerability is an unknown functionality of the file /WiFi.html of the component SSID Handler. The manipulation leads to cross site scripting. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-245065 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Impacted products
Vendor Product Version
intelbras rx_1500_firmware 1.1.9
intelbras rx_1500 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intelbras:rx_1500_firmware:1.1.9:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C2DC877-EEB9-4837-A28C-0D37ACD9FB8D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intelbras:rx_1500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B3E00F0-4F8F-4A2F-A553-74B0C682EF3C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been found in Intelbras RX 1500 1.1.9 and classified as problematic. Affected by this vulnerability is an unknown functionality of the file /WiFi.html of the component SSID Handler. The manipulation leads to cross site scripting. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-245065 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad fue encontrada en Intelbras RX 1500 1.1.9 y clasificada como problem\u00e1tica. Una funci\u00f3n desconocida del archivo /WiFi.html del componente SSID Handler es afectada por esta vulnerabilidad. La manipulaci\u00f3n conduce a cross site scripting. El ataque se puede lanzar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. A esta vulnerabilidad se le asign\u00f3 el identificador VDB-245065. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
    }
  ],
  "id": "CVE-2023-6103",
  "lastModified": "2024-11-21T08:43:08.560",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "MULTIPLE",
          "availabilityImpact": "NONE",
          "baseScore": 3.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:M/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.4,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "cna@vuldb.com",
        "type": "Secondary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 2.4,
          "baseSeverity": "LOW",
          "confidentialityImpact": "NONE",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 0.9,
        "impactScore": 1.4,
        "source": "cna@vuldb.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.4,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "LOW",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.3,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-11-13T18:15:08.470",
  "references": [
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Permissions Required",
        "Third Party Advisory"
      ],
      "url": "https://vuldb.com/?ctiid.245065"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://vuldb.com/?id.245065"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.youtube.com/watch?v=BFoGAuEGpvI"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Permissions Required",
        "Third Party Advisory"
      ],
      "url": "https://vuldb.com/?ctiid.245065"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://vuldb.com/?id.245065"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.youtube.com/watch?v=BFoGAuEGpvI"
    }
  ],
  "sourceIdentifier": "cna@vuldb.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "cna@vuldb.com",
      "type": "Secondary"
    }
  ]
}

CVE-2025-26065 (GCVE-0-2025-26065)

Vulnerability from cvelistv5 – Published: 2025-08-04 00:00 – Updated: 2025-11-03 19:45
VLAI?
Summary
A cross-site scripting (XSS) vulnerability in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows attackers to execute arbitrary web scripts or HTML via injecting a crafted payload into the name of a visiting Wi-Fi network.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 7.3,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-26065",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-04T14:46:46.073181Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-79",
                "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-04T14:48:45.605Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-03T19:45:20.059Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://seclists.org/fulldisclosure/2025/Jul/26"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A cross-site scripting (XSS) vulnerability in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows attackers to execute arbitrary web scripts or HTML via injecting a crafted payload into the name of a visiting Wi-Fi network."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-04T14:14:46.874Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX1500.html"
        },
        {
          "url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX3000.html"
        },
        {
          "url": "https://seclists.org/fulldisclosure/2025/Jul/26"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-26065",
    "datePublished": "2025-08-04T00:00:00.000Z",
    "dateReserved": "2025-02-07T00:00:00.000Z",
    "dateUpdated": "2025-11-03T19:45:20.059Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-26064 (GCVE-0-2025-26064)

Vulnerability from cvelistv5 – Published: 2025-07-31 00:00 – Updated: 2025-11-03 19:45
VLAI?
Summary
A cross-site scripting (XSS) vulnerability in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows attackers to execute arbitrary web scripts or HTML via injecting a crafted payload into the name of a connnected device.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 7.3,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-26064",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-31T19:29:25.304480Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-79",
                "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-31T19:30:25.447Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-03T19:45:18.531Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://seclists.org/fulldisclosure/2025/Jul/26"
          },
          {
            "url": "http://seclists.org/fulldisclosure/2025/Jul/14"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A cross-site scripting (XSS) vulnerability in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows attackers to execute arbitrary web scripts or HTML via injecting a crafted payload into the name of a connnected device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-31T18:43:25.551Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX1500.html"
        },
        {
          "url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX3000.html"
        },
        {
          "url": "https://seclists.org/fulldisclosure/2025/Jul/14"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-26064",
    "datePublished": "2025-07-31T00:00:00.000Z",
    "dateReserved": "2025-02-07T00:00:00.000Z",
    "dateUpdated": "2025-11-03T19:45:18.531Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-26063 (GCVE-0-2025-26063)

Vulnerability from cvelistv5 – Published: 2025-07-31 00:00 – Updated: 2025-11-03 19:45
VLAI?
Summary
An issue in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows unauthenticated attackers to execute arbitrary code via injecting a crafted payload into the ESSID name when creating a network.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-26063",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-31T19:34:56.023904Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-77",
                "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-31T19:35:46.460Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-03T19:45:15.195Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://seclists.org/fulldisclosure/2025/Jul/26"
          },
          {
            "url": "http://seclists.org/fulldisclosure/2025/Jul/14"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows unauthenticated attackers to execute arbitrary code via injecting a crafted payload into the ESSID name when creating a network."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-31T18:42:35.162Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX1500.html"
        },
        {
          "url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX3000.html"
        },
        {
          "url": "https://seclists.org/fulldisclosure/2025/Jul/14"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-26063",
    "datePublished": "2025-07-31T00:00:00.000Z",
    "dateReserved": "2025-02-07T00:00:00.000Z",
    "dateUpdated": "2025-11-03T19:45:15.195Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-26062 (GCVE-0-2025-26062)

Vulnerability from cvelistv5 – Published: 2025-07-31 00:00 – Updated: 2025-11-03 19:45
VLAI?
Summary
An access control issue in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows unauthenticated attackers to access the router's settings file and obtain potentially sensitive information from the current settings.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-26062",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-31T19:41:25.877976Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-284",
                "description": "CWE-284 Improper Access Control",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-31T19:42:07.212Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-03T19:45:12.355Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://seclists.org/fulldisclosure/2025/Jul/26"
          },
          {
            "url": "http://seclists.org/fulldisclosure/2025/Jul/14"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An access control issue in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows unauthenticated attackers to access the router\u0027s settings file and obtain potentially sensitive information from the current settings."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-31T18:42:04.096Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX1500.html"
        },
        {
          "url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX3000.html"
        },
        {
          "url": "https://seclists.org/fulldisclosure/2025/Jul/14"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-26062",
    "datePublished": "2025-07-31T00:00:00.000Z",
    "dateReserved": "2025-02-07T00:00:00.000Z",
    "dateUpdated": "2025-11-03T19:45:12.355Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-50404 (GCVE-0-2025-50404)

Vulnerability from cvelistv5 – Published: 2025-07-01 00:00 – Updated: 2025-07-08 15:42
VLAI?
Summary
Intelbras RX1500 Router v2.2.17 and before is vulnerable to Integer Overflow. The websReadEvent function incorrectly uses the int type when processing the "command" field of the http header, causing the array to cross the boundary and overwrite other fields in the array.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-50404",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-01T14:43:34.527934Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-190",
                "description": "CWE-190 Integer Overflow or Wraparound",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-08T15:42:43.267Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Intelbras RX1500 Router v2.2.17 and before is vulnerable to Integer Overflow. The websReadEvent function incorrectly uses the int type when processing the \"command\" field of the http header, causing the array to cross the boundary and overwrite other fields in the array."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-01T14:27:17.252Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.intelbras.com/en"
        },
        {
          "url": "https://github.com/feiwuxingxie/cve/blob/main/Intelbras/vul01/01.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-50404",
    "datePublished": "2025-07-01T00:00:00.000Z",
    "dateReserved": "2025-06-16T00:00:00.000Z",
    "dateUpdated": "2025-07-08T15:42:43.267Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-50405 (GCVE-0-2025-50405)

Vulnerability from cvelistv5 – Published: 2025-07-01 00:00 – Updated: 2025-07-01 18:23
VLAI?
Summary
Intelbras RX1500 Router v2.2.17 and before is vulnerable to Incorrect Access Control in the FirmwareUpload function and GetFirmwareValidation function.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-50405",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-01T18:22:27.905908Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-284",
                "description": "CWE-284 Improper Access Control",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-01T18:23:19.719Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Intelbras RX1500 Router v2.2.17 and before is vulnerable to Incorrect Access Control in the FirmwareUpload function and GetFirmwareValidation function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-01T14:28:17.350Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.intelbras.com/en"
        },
        {
          "url": "https://github.com/feiwuxingxie/cve/blob/main/Intelbras/vul02/02.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-50405",
    "datePublished": "2025-07-01T00:00:00.000Z",
    "dateReserved": "2025-06-16T00:00:00.000Z",
    "dateUpdated": "2025-07-01T18:23:19.719Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-6103 (GCVE-0-2023-6103)

Vulnerability from cvelistv5 – Published: 2023-11-13 17:31 – Updated: 2025-01-08 21:14
VLAI?
Title
Intelbras RX 1500 SSID WiFi.html cross site scripting
Summary
A vulnerability has been found in Intelbras RX 1500 1.1.9 and classified as problematic. Affected by this vulnerability is an unknown functionality of the file /WiFi.html of the component SSID Handler. The manipulation leads to cross site scripting. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-245065 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-79 - Cross Site Scripting
Assigner
References
Impacted products
Vendor Product Version
Intelbras RX 1500 Affected: 1.1.9
Create a notification for this product.
Credits
Gab3 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:21:17.400Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vdb-entry",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.245065"
          },
          {
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.245065"
          },
          {
            "tags": [
              "exploit",
              "media-coverage",
              "x_transferred"
            ],
            "url": "https://www.youtube.com/watch?v=BFoGAuEGpvI"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-6103",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2023-11-20T15:40:00.393555Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-08T21:14:16.024Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "SSID Handler"
          ],
          "product": "RX 1500",
          "vendor": "Intelbras",
          "versions": [
            {
              "status": "affected",
              "version": "1.1.9"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "analyst",
          "value": "Gab3 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Intelbras RX 1500 1.1.9 and classified as problematic. Affected by this vulnerability is an unknown functionality of the file /WiFi.html of the component SSID Handler. The manipulation leads to cross site scripting. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-245065 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Intelbras RX 1500 1.1.9 wurde eine Schwachstelle gefunden. Sie wurde als problematisch eingestuft. Es geht um eine nicht n\u00e4her bekannte Funktion der Datei /WiFi.html der Komponente SSID Handler. Durch das Manipulieren mit unbekannten Daten kann eine cross site scripting-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 2.4,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 2.4,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 3.3,
            "vectorString": "AV:N/AC:L/Au:M/C:N/I:P/A:N",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Cross Site Scripting",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-13T17:31:06.305Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "tags": [
            "vdb-entry"
          ],
          "url": "https://vuldb.com/?id.245065"
        },
        {
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.245065"
        },
        {
          "tags": [
            "exploit",
            "media-coverage"
          ],
          "url": "https://www.youtube.com/watch?v=BFoGAuEGpvI"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2023-11-13T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2023-11-13T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2023-11-13T11:29:38.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Intelbras RX 1500 SSID WiFi.html cross site scripting"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2023-6103",
    "datePublished": "2023-11-13T17:31:06.305Z",
    "dateReserved": "2023-11-13T10:23:52.210Z",
    "dateUpdated": "2025-01-08T21:14:16.024Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-26065 (GCVE-0-2025-26065)

Vulnerability from nvd – Published: 2025-08-04 00:00 – Updated: 2025-11-03 19:45
VLAI?
Summary
A cross-site scripting (XSS) vulnerability in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows attackers to execute arbitrary web scripts or HTML via injecting a crafted payload into the name of a visiting Wi-Fi network.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 7.3,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-26065",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-04T14:46:46.073181Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-79",
                "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-04T14:48:45.605Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-03T19:45:20.059Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://seclists.org/fulldisclosure/2025/Jul/26"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A cross-site scripting (XSS) vulnerability in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows attackers to execute arbitrary web scripts or HTML via injecting a crafted payload into the name of a visiting Wi-Fi network."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-04T14:14:46.874Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX1500.html"
        },
        {
          "url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX3000.html"
        },
        {
          "url": "https://seclists.org/fulldisclosure/2025/Jul/26"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-26065",
    "datePublished": "2025-08-04T00:00:00.000Z",
    "dateReserved": "2025-02-07T00:00:00.000Z",
    "dateUpdated": "2025-11-03T19:45:20.059Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-26064 (GCVE-0-2025-26064)

Vulnerability from nvd – Published: 2025-07-31 00:00 – Updated: 2025-11-03 19:45
VLAI?
Summary
A cross-site scripting (XSS) vulnerability in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows attackers to execute arbitrary web scripts or HTML via injecting a crafted payload into the name of a connnected device.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 7.3,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-26064",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-31T19:29:25.304480Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-79",
                "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-31T19:30:25.447Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-03T19:45:18.531Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://seclists.org/fulldisclosure/2025/Jul/26"
          },
          {
            "url": "http://seclists.org/fulldisclosure/2025/Jul/14"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A cross-site scripting (XSS) vulnerability in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows attackers to execute arbitrary web scripts or HTML via injecting a crafted payload into the name of a connnected device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-31T18:43:25.551Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX1500.html"
        },
        {
          "url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX3000.html"
        },
        {
          "url": "https://seclists.org/fulldisclosure/2025/Jul/14"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-26064",
    "datePublished": "2025-07-31T00:00:00.000Z",
    "dateReserved": "2025-02-07T00:00:00.000Z",
    "dateUpdated": "2025-11-03T19:45:18.531Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-26063 (GCVE-0-2025-26063)

Vulnerability from nvd – Published: 2025-07-31 00:00 – Updated: 2025-11-03 19:45
VLAI?
Summary
An issue in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows unauthenticated attackers to execute arbitrary code via injecting a crafted payload into the ESSID name when creating a network.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-26063",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-31T19:34:56.023904Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-77",
                "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-31T19:35:46.460Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-03T19:45:15.195Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://seclists.org/fulldisclosure/2025/Jul/26"
          },
          {
            "url": "http://seclists.org/fulldisclosure/2025/Jul/14"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows unauthenticated attackers to execute arbitrary code via injecting a crafted payload into the ESSID name when creating a network."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-31T18:42:35.162Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX1500.html"
        },
        {
          "url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX3000.html"
        },
        {
          "url": "https://seclists.org/fulldisclosure/2025/Jul/14"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-26063",
    "datePublished": "2025-07-31T00:00:00.000Z",
    "dateReserved": "2025-02-07T00:00:00.000Z",
    "dateUpdated": "2025-11-03T19:45:15.195Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-26062 (GCVE-0-2025-26062)

Vulnerability from nvd – Published: 2025-07-31 00:00 – Updated: 2025-11-03 19:45
VLAI?
Summary
An access control issue in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows unauthenticated attackers to access the router's settings file and obtain potentially sensitive information from the current settings.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-26062",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-31T19:41:25.877976Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-284",
                "description": "CWE-284 Improper Access Control",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-31T19:42:07.212Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-03T19:45:12.355Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://seclists.org/fulldisclosure/2025/Jul/26"
          },
          {
            "url": "http://seclists.org/fulldisclosure/2025/Jul/14"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An access control issue in Intelbras RX1500 v2.2.9 and RX3000 v1.0.11 allows unauthenticated attackers to access the router\u0027s settings file and obtain potentially sensitive information from the current settings."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-31T18:42:04.096Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX1500.html"
        },
        {
          "url": "https://manuais.intelbras.com.br/manual-linha-rx/ChangeLogRX3000.html"
        },
        {
          "url": "https://seclists.org/fulldisclosure/2025/Jul/14"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-26062",
    "datePublished": "2025-07-31T00:00:00.000Z",
    "dateReserved": "2025-02-07T00:00:00.000Z",
    "dateUpdated": "2025-11-03T19:45:12.355Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-50404 (GCVE-0-2025-50404)

Vulnerability from nvd – Published: 2025-07-01 00:00 – Updated: 2025-07-08 15:42
VLAI?
Summary
Intelbras RX1500 Router v2.2.17 and before is vulnerable to Integer Overflow. The websReadEvent function incorrectly uses the int type when processing the "command" field of the http header, causing the array to cross the boundary and overwrite other fields in the array.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-50404",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-01T14:43:34.527934Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-190",
                "description": "CWE-190 Integer Overflow or Wraparound",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-08T15:42:43.267Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Intelbras RX1500 Router v2.2.17 and before is vulnerable to Integer Overflow. The websReadEvent function incorrectly uses the int type when processing the \"command\" field of the http header, causing the array to cross the boundary and overwrite other fields in the array."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-01T14:27:17.252Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.intelbras.com/en"
        },
        {
          "url": "https://github.com/feiwuxingxie/cve/blob/main/Intelbras/vul01/01.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-50404",
    "datePublished": "2025-07-01T00:00:00.000Z",
    "dateReserved": "2025-06-16T00:00:00.000Z",
    "dateUpdated": "2025-07-08T15:42:43.267Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-50405 (GCVE-0-2025-50405)

Vulnerability from nvd – Published: 2025-07-01 00:00 – Updated: 2025-07-01 18:23
VLAI?
Summary
Intelbras RX1500 Router v2.2.17 and before is vulnerable to Incorrect Access Control in the FirmwareUpload function and GetFirmwareValidation function.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-50405",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-01T18:22:27.905908Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-284",
                "description": "CWE-284 Improper Access Control",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-01T18:23:19.719Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Intelbras RX1500 Router v2.2.17 and before is vulnerable to Incorrect Access Control in the FirmwareUpload function and GetFirmwareValidation function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-01T14:28:17.350Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.intelbras.com/en"
        },
        {
          "url": "https://github.com/feiwuxingxie/cve/blob/main/Intelbras/vul02/02.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-50405",
    "datePublished": "2025-07-01T00:00:00.000Z",
    "dateReserved": "2025-06-16T00:00:00.000Z",
    "dateUpdated": "2025-07-01T18:23:19.719Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-6103 (GCVE-0-2023-6103)

Vulnerability from nvd – Published: 2023-11-13 17:31 – Updated: 2025-01-08 21:14
VLAI?
Title
Intelbras RX 1500 SSID WiFi.html cross site scripting
Summary
A vulnerability has been found in Intelbras RX 1500 1.1.9 and classified as problematic. Affected by this vulnerability is an unknown functionality of the file /WiFi.html of the component SSID Handler. The manipulation leads to cross site scripting. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-245065 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-79 - Cross Site Scripting
Assigner
References
Impacted products
Vendor Product Version
Intelbras RX 1500 Affected: 1.1.9
Create a notification for this product.
Credits
Gab3 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:21:17.400Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vdb-entry",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.245065"
          },
          {
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.245065"
          },
          {
            "tags": [
              "exploit",
              "media-coverage",
              "x_transferred"
            ],
            "url": "https://www.youtube.com/watch?v=BFoGAuEGpvI"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-6103",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2023-11-20T15:40:00.393555Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-08T21:14:16.024Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "SSID Handler"
          ],
          "product": "RX 1500",
          "vendor": "Intelbras",
          "versions": [
            {
              "status": "affected",
              "version": "1.1.9"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "analyst",
          "value": "Gab3 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Intelbras RX 1500 1.1.9 and classified as problematic. Affected by this vulnerability is an unknown functionality of the file /WiFi.html of the component SSID Handler. The manipulation leads to cross site scripting. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-245065 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Intelbras RX 1500 1.1.9 wurde eine Schwachstelle gefunden. Sie wurde als problematisch eingestuft. Es geht um eine nicht n\u00e4her bekannte Funktion der Datei /WiFi.html der Komponente SSID Handler. Durch das Manipulieren mit unbekannten Daten kann eine cross site scripting-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 2.4,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 2.4,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 3.3,
            "vectorString": "AV:N/AC:L/Au:M/C:N/I:P/A:N",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Cross Site Scripting",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-13T17:31:06.305Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "tags": [
            "vdb-entry"
          ],
          "url": "https://vuldb.com/?id.245065"
        },
        {
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.245065"
        },
        {
          "tags": [
            "exploit",
            "media-coverage"
          ],
          "url": "https://www.youtube.com/watch?v=BFoGAuEGpvI"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2023-11-13T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2023-11-13T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2023-11-13T11:29:38.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Intelbras RX 1500 SSID WiFi.html cross site scripting"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2023-6103",
    "datePublished": "2023-11-13T17:31:06.305Z",
    "dateReserved": "2023-11-13T10:23:52.210Z",
    "dateUpdated": "2025-01-08T21:14:16.024Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}