Vulnerabilites related to linksys - re6400
var-201907-1574
Vulnerability from variot

Unsanitized user input in the web interface for Linksys WiFi extender products (RE6400 and RE6300 through 1.2.04.022) allows for remote command execution. An attacker can access system OS configurations and commands that are not intended for use beyond the web UI. Linksys WiFi extender RE6400 and RE6300 Contains an input validation vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Linksys RE6400 and Linksys RE6300 are both a wireless network signal extender from Linksys in the United States. There is a security vulnerability in the web interface of Linksys RE6400 1.2.04.022 and earlier versions and RE6300 1.2.04.022 and earlier versions. The vulnerability is caused by the program not filtering user input

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201907-1574",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "re6400",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "linksys",
        "version": "1.2.04.022"
      },
      {
        "model": "re6300",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "linksys",
        "version": "1.2.04.022"
      },
      {
        "model": "re6300",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "cisco linksys",
        "version": "1.2.04.022"
      },
      {
        "model": "re6400",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "cisco linksys",
        "version": "1.2.04.022"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-006723"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-11535"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:linksys:re6300_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:linksys:re6400_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-006723"
      }
    ]
  },
  "cve": "CVE-2019-11535",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2019-11535",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "VHN-143191",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2019-11535",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2019-11535",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2019-11535",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201907-1005",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-143191",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-143191"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-006723"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201907-1005"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-11535"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Unsanitized user input in the web interface for Linksys WiFi extender products (RE6400 and RE6300 through 1.2.04.022) allows for remote command execution. An attacker can access system OS configurations and commands that are not intended for use beyond the web UI. Linksys WiFi extender RE6400 and RE6300 Contains an input validation vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Linksys RE6400 and Linksys RE6300 are both a wireless network signal extender from Linksys in the United States. There is a security vulnerability in the web interface of Linksys RE6400 1.2.04.022 and earlier versions and RE6300 1.2.04.022 and earlier versions. The vulnerability is caused by the program not filtering user input",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-11535"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-006723"
      },
      {
        "db": "VULHUB",
        "id": "VHN-143191"
      }
    ],
    "trust": 1.71
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-11535",
        "trust": 2.5
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-006723",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201907-1005",
        "trust": 0.7
      },
      {
        "db": "VULHUB",
        "id": "VHN-143191",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-143191"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-006723"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201907-1005"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-11535"
      }
    ]
  },
  "id": "VAR-201907-1574",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-143191"
      }
    ],
    "trust": 0.01
  },
  "last_update_date": "2024-11-23T22:48:20.932000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "WiFi EXTENDER",
        "trust": 0.8,
        "url": "https://www.linksys.com/us/range-extenders/c/wireless-wi-fi-range-extenders/?q=%3AsortByProductRank\u0026page=0"
      },
      {
        "title": "Linksys RE6400  and Linksys RE6300 Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=95298"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-006723"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201907-1005"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-77",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-20",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-143191"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-006723"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-11535"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "http://s3.amazonaws.com/downloads.linksys.com/support/assets/releasenotes/linksys%20re6300%20re6400%20firmware%20release%20notes_v1.2.05.001.txt"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-11535"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-11535"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-143191"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-006723"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201907-1005"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-11535"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-143191"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-006723"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201907-1005"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-11535"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-07-17T00:00:00",
        "db": "VULHUB",
        "id": "VHN-143191"
      },
      {
        "date": "2019-07-25T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-006723"
      },
      {
        "date": "2019-07-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201907-1005"
      },
      {
        "date": "2019-07-17T20:15:10.897000",
        "db": "NVD",
        "id": "CVE-2019-11535"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-08-24T00:00:00",
        "db": "VULHUB",
        "id": "VHN-143191"
      },
      {
        "date": "2019-07-25T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-006723"
      },
      {
        "date": "2020-08-25T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201907-1005"
      },
      {
        "date": "2024-11-21T04:21:17.377000",
        "db": "NVD",
        "id": "CVE-2019-11535"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201907-1005"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Linksys WiFi extender RE6400 and  RE6300 Input validation vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-006723"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "command injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201907-1005"
      }
    ],
    "trust": 0.6
  }
}

CVE-2019-11535 (GCVE-0-2019-11535)
Vulnerability from cvelistv5
Published
2019-07-17 19:35
Modified
2024-08-04 22:55
Severity ?
CWE
  • n/a
Summary
Unsanitized user input in the web interface for Linksys WiFi extender products (RE6400 and RE6300 through 1.2.04.022) allows for remote command execution. An attacker can access system OS configurations and commands that are not intended for use beyond the web UI.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:55:40.673Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://s3.amazonaws.com/downloads.linksys.com/support/assets/releasenotes/Linksys%20RE6300%20RE6400%20Firmware%20Release%20Notes_v1.2.05.001.txt"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Unsanitized user input in the web interface for Linksys WiFi extender products (RE6400 and RE6300 through 1.2.04.022) allows for remote command execution. An attacker can access system OS configurations and commands that are not intended for use beyond the web UI."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-07-17T19:35:09",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://s3.amazonaws.com/downloads.linksys.com/support/assets/releasenotes/Linksys%20RE6300%20RE6400%20Firmware%20Release%20Notes_v1.2.05.001.txt"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2019-11535",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Unsanitized user input in the web interface for Linksys WiFi extender products (RE6400 and RE6300 through 1.2.04.022) allows for remote command execution. An attacker can access system OS configurations and commands that are not intended for use beyond the web UI."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://s3.amazonaws.com/downloads.linksys.com/support/assets/releasenotes/Linksys%20RE6300%20RE6400%20Firmware%20Release%20Notes_v1.2.05.001.txt",
              "refsource": "CONFIRM",
              "url": "http://s3.amazonaws.com/downloads.linksys.com/support/assets/releasenotes/Linksys%20RE6300%20RE6400%20Firmware%20Release%20Notes_v1.2.05.001.txt"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2019-11535",
    "datePublished": "2019-07-17T19:35:09",
    "dateReserved": "2019-04-25T00:00:00",
    "dateUpdated": "2024-08-04T22:55:40.673Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Vulnerability from fkie_nvd
Published
2019-07-17 20:15
Modified
2024-11-21 04:21
Severity ?
Summary
Unsanitized user input in the web interface for Linksys WiFi extender products (RE6400 and RE6300 through 1.2.04.022) allows for remote command execution. An attacker can access system OS configurations and commands that are not intended for use beyond the web UI.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:linksys:re6400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4DF60203-25C2-4CC9-A052-224816459F25",
              "versionEndIncluding": "1.2.04.022",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:linksys:re6400:1:*:*:*:*:*:*:*",
              "matchCriteriaId": "21D1A8F3-A23D-4655-9AD0-DBCC2B29B6FD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:linksys:re6300_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "704816A7-8E47-421F-BC1C-56EC8441D9C1",
              "versionEndIncluding": "1.2.04.022",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:linksys:re6300:1:*:*:*:*:*:*:*",
              "matchCriteriaId": "59B144B4-E40D-466B-973C-02465113B402",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Unsanitized user input in the web interface for Linksys WiFi extender products (RE6400 and RE6300 through 1.2.04.022) allows for remote command execution. An attacker can access system OS configurations and commands that are not intended for use beyond the web UI."
    },
    {
      "lang": "es",
      "value": "Una entrada de usuario no saneada en la interfaz web para los productos extensores de WiFi de Linksys (RE6400 y RE6300 hasta versi\u00f3n 1.2.04.022), permite la ejecuci\u00f3n de comandos remota. Un atacante puede acceder a las configuraciones del sistema operativo del sistema y a los comandos que no fueron destinados para su uso fuera de la interfaz de usuario web."
    }
  ],
  "id": "CVE-2019-11535",
  "lastModified": "2024-11-21T04:21:17.377",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-07-17T20:15:10.897",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Release Notes",
        "Third Party Advisory"
      ],
      "url": "http://s3.amazonaws.com/downloads.linksys.com/support/assets/releasenotes/Linksys%20RE6300%20RE6400%20Firmware%20Release%20Notes_v1.2.05.001.txt"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes",
        "Third Party Advisory"
      ],
      "url": "http://s3.amazonaws.com/downloads.linksys.com/support/assets/releasenotes/Linksys%20RE6300%20RE6400%20Firmware%20Release%20Notes_v1.2.05.001.txt"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}