Summary
Core Server HMI Service (Coreservice.exe) in Scadatec Limited Procyon SCADA 1.06, and other versions before 1.14, allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a long password to the Telnet (TCP/23) port, which triggers an out-of-bounds read or write, leading to a stack-based buffer overflow.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
scadatec | procyon_scada | 1.06 | |
scadatec | procyon_scada | 1.13 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:scadatec:procyon_scada:1.06:*:*:*:*:*:*:*", "matchCriteriaId": "711729FE-8DE0-4B56-AF6E-4066E89A0656", "vulnerable": true }, { "criteria": "cpe:2.3:a:scadatec:procyon_scada:1.13:*:*:*:*:*:*:*", "matchCriteriaId": "B5AEC507-E292-4FBA-B4DC-AFC2CF3BA835", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Core Server HMI Service (Coreservice.exe) in Scadatec Limited Procyon SCADA 1.06, and other versions before 1.14, allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a long password to the Telnet (TCP/23) port, which triggers an out-of-bounds read or write, leading to a stack-based buffer overflow." }, { "lang": "es", "value": "Core Server HMI Service (Coreservice.exe) en Scadatec Limited Procyon SCADA v1.06, y otras versiones antes de v1.14, permite a atacantes remotos provocar una denegaci\u00f3n de servicio (ca\u00edda) y posiblemente ejecutar c\u00eddgo de su elecci\u00f3n a trav\u00e9s de una contrase\u00f1a larga para el puerto Telnet (TCP/23), lo que provoca una lectura o escritura fuera de l\u00edmites que provoca un desbordamiento de b\u00fafer basado en pila." } ], "id": "CVE-2011-3322", "lastModified": "2025-04-11T00:51:21.963", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ] }, "published": "2011-09-15T17:58:42.403", "references": [ { "source": "cret@cert.org", "url": "http://osvdb.org/75371" }, { "source": "cret@cert.org", "tags": [ "Vendor Advisory" ], "url": "http://secunia.com/advisories/45866" }, { "source": "cret@cert.org", "url": "http://securityreason.com/securityalert/8374" }, { "source": "cret@cert.org", "tags": [ "Exploit" ], "url": "http://www.exploit-db.com/exploits/17827" }, { "source": "cret@cert.org", "url": "http://www.securityfocus.com/bid/49480" }, { "source": "cret@cert.org", "url": "http://www.stratsec.net/Research/Advisories/Procyon-Core-Server-HMI-Remote-Stack-Overflow" }, { "source": "cret@cert.org", "tags": [ "US Government Resource" ], "url": "http://www.uscert.gov/control_systems/pdf/ICSA-11-216-01.pdf" }, { "source": "cret@cert.org", "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69632" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://osvdb.org/75371" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://secunia.com/advisories/45866" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://securityreason.com/securityalert/8374" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit" ], "url": "http://www.exploit-db.com/exploits/17827" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://www.securityfocus.com/bid/49480" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://www.stratsec.net/Research/Advisories/Procyon-Core-Server-HMI-Remote-Stack-Overflow" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "US Government Resource" ], "url": "http://www.uscert.gov/control_systems/pdf/ICSA-11-216-01.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69632" } ], "sourceIdentifier": "cret@cert.org", "vulnStatus": "Deferred", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
CVE-2011-3322 (GCVE-0-2011-3322)
Vulnerability from cvelistv5
Published
2011-09-15 17:00
Modified
2024-08-06 23:29
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Core Server HMI Service (Coreservice.exe) in Scadatec Limited Procyon SCADA 1.06, and other versions before 1.14, allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a long password to the Telnet (TCP/23) port, which triggers an out-of-bounds read or write, leading to a stack-based buffer overflow.
References
▼ | URL | Tags |
---|---|---|
http://www.exploit-db.com/exploits/17827 | exploit, x_refsource_EXPLOIT-DB | |
https://exchange.xforce.ibmcloud.com/vulnerabilities/69632 | vdb-entry, x_refsource_XF | |
http://www.stratsec.net/Research/Advisories/Procyon-Core-Server-HMI-Remote-Stack-Overflow | x_refsource_MISC | |
http://secunia.com/advisories/45866 | third-party-advisory, x_refsource_SECUNIA | |
http://www.uscert.gov/control_systems/pdf/ICSA-11-216-01.pdf | x_refsource_MISC | |
http://securityreason.com/securityalert/8374 | third-party-advisory, x_refsource_SREASON | |
http://osvdb.org/75371 | vdb-entry, x_refsource_OSVDB | |
http://www.securityfocus.com/bid/49480 | vdb-entry, x_refsource_BID |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T23:29:56.757Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "17827", "tags": [ "exploit", "x_refsource_EXPLOIT-DB", "x_transferred" ], "url": "http://www.exploit-db.com/exploits/17827" }, { "name": "procyon-telnet-bo(69632)", "tags": [ "vdb-entry", "x_refsource_XF", "x_transferred" ], "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69632" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://www.stratsec.net/Research/Advisories/Procyon-Core-Server-HMI-Remote-Stack-Overflow" }, { "name": "45866", "tags": [ "third-party-advisory", "x_refsource_SECUNIA", "x_transferred" ], "url": "http://secunia.com/advisories/45866" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://www.uscert.gov/control_systems/pdf/ICSA-11-216-01.pdf" }, { "name": "8374", "tags": [ "third-party-advisory", "x_refsource_SREASON", "x_transferred" ], "url": "http://securityreason.com/securityalert/8374" }, { "name": "75371", "tags": [ "vdb-entry", "x_refsource_OSVDB", "x_transferred" ], "url": "http://osvdb.org/75371" }, { "name": "49480", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/49480" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2011-09-06T00:00:00", "descriptions": [ { "lang": "en", "value": "Core Server HMI Service (Coreservice.exe) in Scadatec Limited Procyon SCADA 1.06, and other versions before 1.14, allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a long password to the Telnet (TCP/23) port, which triggers an out-of-bounds read or write, leading to a stack-based buffer overflow." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2017-08-28T12:57:01", "orgId": "37e5125f-f79b-445b-8fad-9564f167944b", "shortName": "certcc" }, "references": [ { "name": "17827", "tags": [ "exploit", "x_refsource_EXPLOIT-DB" ], "url": "http://www.exploit-db.com/exploits/17827" }, { "name": "procyon-telnet-bo(69632)", "tags": [ "vdb-entry", "x_refsource_XF" ], "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69632" }, { "tags": [ "x_refsource_MISC" ], "url": "http://www.stratsec.net/Research/Advisories/Procyon-Core-Server-HMI-Remote-Stack-Overflow" }, { "name": "45866", "tags": [ "third-party-advisory", "x_refsource_SECUNIA" ], "url": "http://secunia.com/advisories/45866" }, { "tags": [ "x_refsource_MISC" ], "url": "http://www.uscert.gov/control_systems/pdf/ICSA-11-216-01.pdf" }, { "name": "8374", "tags": [ "third-party-advisory", "x_refsource_SREASON" ], "url": "http://securityreason.com/securityalert/8374" }, { "name": "75371", "tags": [ "vdb-entry", "x_refsource_OSVDB" ], "url": "http://osvdb.org/75371" }, { "name": "49480", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/49480" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cert@cert.org", "ID": "CVE-2011-3322", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Core Server HMI Service (Coreservice.exe) in Scadatec Limited Procyon SCADA 1.06, and other versions before 1.14, allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a long password to the Telnet (TCP/23) port, which triggers an out-of-bounds read or write, leading to a stack-based buffer overflow." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "17827", "refsource": "EXPLOIT-DB", "url": "http://www.exploit-db.com/exploits/17827" }, { "name": "procyon-telnet-bo(69632)", "refsource": "XF", "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69632" }, { "name": "http://www.stratsec.net/Research/Advisories/Procyon-Core-Server-HMI-Remote-Stack-Overflow", "refsource": "MISC", "url": "http://www.stratsec.net/Research/Advisories/Procyon-Core-Server-HMI-Remote-Stack-Overflow" }, { "name": "45866", "refsource": "SECUNIA", "url": "http://secunia.com/advisories/45866" }, { "name": "http://www.uscert.gov/control_systems/pdf/ICSA-11-216-01.pdf", "refsource": "MISC", "url": "http://www.uscert.gov/control_systems/pdf/ICSA-11-216-01.pdf" }, { "name": "8374", "refsource": "SREASON", "url": "http://securityreason.com/securityalert/8374" }, { "name": "75371", "refsource": "OSVDB", "url": "http://osvdb.org/75371" }, { "name": "49480", "refsource": "BID", "url": "http://www.securityfocus.com/bid/49480" } ] } } } }, "cveMetadata": { "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b", "assignerShortName": "certcc", "cveId": "CVE-2011-3322", "datePublished": "2011-09-15T17:00:00", "dateReserved": "2011-08-29T00:00:00", "dateUpdated": "2024-08-06T23:29:56.757Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }