Refine your search

10 vulnerabilities found for mivoice_connect by mitel

CVE-2023-25599 (GCVE-0-2023-25599)
Vulnerability from nvd
Published
2023-05-24 00:00
Modified
2025-01-16 20:15
CWE
  • n/a
Summary
A vulnerability in the conferencing component of Mitel MiVoice Connect through 19.3 SP2, 22.24.1500.0 could allow an unauthenticated attacker to conduct a reflected cross-site scripting (XSS) attack due to insufficient validation for the test_presenter.php page. A successful exploit could allow an attacker to execute arbitrary scripts.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T11:25:19.273Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitel.com/support/security-advisories"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-23-0003"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.4,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "CHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:N/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2023-25599",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-16T20:14:59.317120Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-79",
                "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-16T20:15:52.982Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the conferencing component of Mitel MiVoice Connect through 19.3 SP2, 22.24.1500.0 could allow an unauthenticated attacker to conduct a reflected cross-site scripting (XSS) attack due to insufficient validation for the test_presenter.php page. A successful exploit could allow an attacker to execute arbitrary scripts."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-17T18:52:33.354621",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.mitel.com/support/security-advisories"
        },
        {
          "url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-23-0003"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-25599",
    "datePublished": "2023-05-24T00:00:00",
    "dateReserved": "2023-02-08T00:00:00",
    "dateUpdated": "2025-01-16T20:15:52.982Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-41223 (GCVE-0-2022-41223)
Vulnerability from nvd
Published
2022-11-22 00:00
Modified
2025-10-21 23:15
CWE
  • n/a
Summary
The Director database component of MiVoice Connect through 19.3 (22.22.6100.0) could allow an authenticated attacker to conduct a code-injection attack via crafted data due to insufficient restrictions on the database data type.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T12:35:49.557Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitel.com/support/security-advisories"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-22-0008"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.8,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "HIGH",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-41223",
                "options": [
                  {
                    "Exploitation": "active"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-28T21:36:44.326198Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          },
          {
            "other": {
              "content": {
                "dateAdded": "2023-02-21",
                "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2022-41223"
              },
              "type": "kev"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-94",
                "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-21T23:15:30.959Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "government-resource"
            ],
            "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2022-41223"
          }
        ],
        "timeline": [
          {
            "lang": "en",
            "time": "2023-02-21T00:00:00+00:00",
            "value": "CVE-2022-41223 added to CISA KEV"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The Director database component of MiVoice Connect through 19.3 (22.22.6100.0) could allow an authenticated attacker to conduct a code-injection attack via crafted data due to insufficient restrictions on the database data type."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-22T00:00:00.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.mitel.com/support/security-advisories"
        },
        {
          "url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-22-0008"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-41223",
    "datePublished": "2022-11-22T00:00:00.000Z",
    "dateReserved": "2022-09-21T00:00:00.000Z",
    "dateUpdated": "2025-10-21T23:15:30.959Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-40765 (GCVE-0-2022-40765)
Vulnerability from nvd
Published
2022-11-22 00:00
Modified
2025-10-21 23:15
CWE
  • n/a
Summary
A vulnerability in the Edge Gateway component of Mitel MiVoice Connect through 19.3 (22.22.6100.0) could allow an authenticated attacker with internal network access to conduct a command-injection attack, due to insufficient restriction of URL parameters.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T12:28:42.466Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitel.com/support/security-advisories"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-22-0007"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.8,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "HIGH",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-40765",
                "options": [
                  {
                    "Exploitation": "active"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-28T21:37:20.585182Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          },
          {
            "other": {
              "content": {
                "dateAdded": "2023-02-21",
                "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2022-40765"
              },
              "type": "kev"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-77",
                "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-21T23:15:31.091Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "government-resource"
            ],
            "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2022-40765"
          }
        ],
        "timeline": [
          {
            "lang": "en",
            "time": "2023-02-21T00:00:00+00:00",
            "value": "CVE-2022-40765 added to CISA KEV"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the Edge Gateway component of Mitel MiVoice Connect through 19.3 (22.22.6100.0) could allow an authenticated attacker with internal network access to conduct a command-injection attack, due to insufficient restriction of URL parameters."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-22T00:00:00.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.mitel.com/support/security-advisories"
        },
        {
          "url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-22-0007"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-40765",
    "datePublished": "2022-11-22T00:00:00.000Z",
    "dateReserved": "2022-09-18T00:00:00.000Z",
    "dateUpdated": "2025-10-21T23:15:31.091Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-29499 (GCVE-0-2022-29499)
Vulnerability from nvd
Published
2022-04-26 01:13
Modified
2025-10-21 23:15
Severity ?
CWE
  • n/a
Summary
The Service Appliance component in Mitel MiVoice Connect through 19.2 SP3 allows remote code execution because of incorrect data validation. The Service Appliances are SA 100, SA 400, and Virtual SA.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:26:06.067Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-22-0002"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-29499",
                "options": [
                  {
                    "Exploitation": "active"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-29T16:10:59.913484Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          },
          {
            "other": {
              "content": {
                "dateAdded": "2022-06-27",
                "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2022-29499"
              },
              "type": "kev"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-20",
                "description": "CWE-20 Improper Input Validation",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-21T23:15:40.565Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "government-resource"
            ],
            "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2022-29499"
          }
        ],
        "timeline": [
          {
            "lang": "en",
            "time": "2022-06-27T00:00:00+00:00",
            "value": "CVE-2022-29499 added to CISA KEV"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The Service Appliance component in Mitel MiVoice Connect through 19.2 SP3 allows remote code execution because of incorrect data validation. The Service Appliances are SA 100, SA 400, and Virtual SA."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-26T01:13:58.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-22-0002"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-29499",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The Service Appliance component in Mitel MiVoice Connect through 19.2 SP3 allows remote code execution because of incorrect data validation. The Service Appliances are SA 100, SA 400, and Virtual SA."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-22-0002",
              "refsource": "CONFIRM",
              "url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-22-0002"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-29499",
    "datePublished": "2022-04-26T01:13:58.000Z",
    "dateReserved": "2022-04-19T00:00:00.000Z",
    "dateUpdated": "2025-10-21T23:15:40.565Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-12456 (GCVE-0-2020-12456)
Vulnerability from nvd
Published
2020-08-26 18:07
Modified
2024-08-04 11:56
Severity ?
CWE
  • n/a
Summary
A remote code execution vulnerability in Mitel MiVoice Connect Client before 214.100.1223.0 could allow an attacker to execute arbitrary code in the chat notification window, due to improper rendering of chat messages. A successful exploit could allow an attacker to steal session cookies, perform directory traversal, and execute arbitrary scripts in the context of the Connect client.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:56:52.052Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.mitel.com/support/security-advisories"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-20-0006"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2020-06-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote code execution vulnerability in Mitel MiVoice Connect Client before 214.100.1223.0 could allow an attacker to execute arbitrary code in the chat notification window, due to improper rendering of chat messages. A successful exploit could allow an attacker to steal session cookies, perform directory traversal, and execute arbitrary scripts in the context of the Connect client."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-08-26T18:07:29",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.mitel.com/support/security-advisories"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-20-0006"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-12456",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote code execution vulnerability in Mitel MiVoice Connect Client before 214.100.1223.0 could allow an attacker to execute arbitrary code in the chat notification window, due to improper rendering of chat messages. A successful exploit could allow an attacker to steal session cookies, perform directory traversal, and execute arbitrary scripts in the context of the Connect client."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.mitel.com/support/security-advisories",
              "refsource": "MISC",
              "url": "https://www.mitel.com/support/security-advisories"
            },
            {
              "name": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-20-0006",
              "refsource": "CONFIRM",
              "url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-20-0006"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-12456",
    "datePublished": "2020-08-26T18:07:29",
    "dateReserved": "2020-04-29T00:00:00",
    "dateUpdated": "2024-08-04T11:56:52.052Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-10377 (GCVE-0-2020-10377)
Vulnerability from nvd
Published
2020-04-17 12:31
Modified
2024-08-04 10:58
Severity ?
CWE
  • n/a
Summary
A weak encryption vulnerability in Mitel MiVoice Connect Client before 214.100.1214.0 could allow an unauthenticated attacker to gain access to user credentials. A successful exploit could allow an attacker to access the system with compromised user credentials.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T10:58:40.623Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.mitel.com/support/security-advisories"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-20-0004"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A weak encryption vulnerability in Mitel MiVoice Connect Client before 214.100.1214.0 could allow an unauthenticated attacker to gain access to user credentials. A successful exploit could allow an attacker to access the system with compromised user credentials."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-04-17T12:31:49",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.mitel.com/support/security-advisories"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-20-0004"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-10377",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A weak encryption vulnerability in Mitel MiVoice Connect Client before 214.100.1214.0 could allow an unauthenticated attacker to gain access to user credentials. A successful exploit could allow an attacker to access the system with compromised user credentials."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.mitel.com/support/security-advisories",
              "refsource": "MISC",
              "url": "https://www.mitel.com/support/security-advisories"
            },
            {
              "name": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-20-0004",
              "refsource": "CONFIRM",
              "url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-20-0004"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-10377",
    "datePublished": "2020-04-17T12:31:49",
    "dateReserved": "2020-03-10T00:00:00",
    "dateUpdated": "2024-08-04T10:58:40.623Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-10211 (GCVE-0-2020-10211)
Vulnerability from nvd
Published
2020-04-17 12:31
Modified
2024-08-04 10:58
Severity ?
CWE
  • n/a
Summary
A remote code execution vulnerability in UCB component of Mitel MiVoice Connect before 19.1 SP1 could allow an unauthenticated remote attacker to execute arbitrary scripts due to insufficient validation of URL parameters. A successful exploit could allow an attacker to gain access to sensitive information.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T10:58:39.545Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.mitel.com/support/security-advisories"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-20-0004"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote code execution vulnerability in UCB component of Mitel MiVoice Connect before 19.1 SP1 could allow an unauthenticated remote attacker to execute arbitrary scripts due to insufficient validation of URL parameters. A successful exploit could allow an attacker to gain access to sensitive information."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-04-17T12:31:02",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.mitel.com/support/security-advisories"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-20-0004"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-10211",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote code execution vulnerability in UCB component of Mitel MiVoice Connect before 19.1 SP1 could allow an unauthenticated remote attacker to execute arbitrary scripts due to insufficient validation of URL parameters. A successful exploit could allow an attacker to gain access to sensitive information."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.mitel.com/support/security-advisories",
              "refsource": "MISC",
              "url": "https://www.mitel.com/support/security-advisories"
            },
            {
              "name": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-20-0004",
              "refsource": "CONFIRM",
              "url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-20-0004"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-10211",
    "datePublished": "2020-04-17T12:31:02",
    "dateReserved": "2020-03-06T00:00:00",
    "dateUpdated": "2024-08-04T10:58:39.545Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-40765 (GCVE-0-2022-40765)
Vulnerability from cvelistv5
Published
2022-11-22 00:00
Modified
2025-10-21 23:15
CWE
  • n/a
Summary
A vulnerability in the Edge Gateway component of Mitel MiVoice Connect through 19.3 (22.22.6100.0) could allow an authenticated attacker with internal network access to conduct a command-injection attack, due to insufficient restriction of URL parameters.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T12:28:42.466Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitel.com/support/security-advisories"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-22-0007"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.8,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "HIGH",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-40765",
                "options": [
                  {
                    "Exploitation": "active"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-28T21:37:20.585182Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          },
          {
            "other": {
              "content": {
                "dateAdded": "2023-02-21",
                "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2022-40765"
              },
              "type": "kev"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-77",
                "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-21T23:15:31.091Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "government-resource"
            ],
            "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2022-40765"
          }
        ],
        "timeline": [
          {
            "lang": "en",
            "time": "2023-02-21T00:00:00+00:00",
            "value": "CVE-2022-40765 added to CISA KEV"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the Edge Gateway component of Mitel MiVoice Connect through 19.3 (22.22.6100.0) could allow an authenticated attacker with internal network access to conduct a command-injection attack, due to insufficient restriction of URL parameters."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-22T00:00:00.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.mitel.com/support/security-advisories"
        },
        {
          "url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-22-0007"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-40765",
    "datePublished": "2022-11-22T00:00:00.000Z",
    "dateReserved": "2022-09-18T00:00:00.000Z",
    "dateUpdated": "2025-10-21T23:15:31.091Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-41223 (GCVE-0-2022-41223)
Vulnerability from cvelistv5
Published
2022-11-22 00:00
Modified
2025-10-21 23:15
CWE
  • n/a
Summary
The Director database component of MiVoice Connect through 19.3 (22.22.6100.0) could allow an authenticated attacker to conduct a code-injection attack via crafted data due to insufficient restrictions on the database data type.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T12:35:49.557Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitel.com/support/security-advisories"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-22-0008"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.8,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "HIGH",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-41223",
                "options": [
                  {
                    "Exploitation": "active"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-28T21:36:44.326198Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          },
          {
            "other": {
              "content": {
                "dateAdded": "2023-02-21",
                "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2022-41223"
              },
              "type": "kev"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-94",
                "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-21T23:15:30.959Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "government-resource"
            ],
            "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2022-41223"
          }
        ],
        "timeline": [
          {
            "lang": "en",
            "time": "2023-02-21T00:00:00+00:00",
            "value": "CVE-2022-41223 added to CISA KEV"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The Director database component of MiVoice Connect through 19.3 (22.22.6100.0) could allow an authenticated attacker to conduct a code-injection attack via crafted data due to insufficient restrictions on the database data type."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-22T00:00:00.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.mitel.com/support/security-advisories"
        },
        {
          "url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-22-0008"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-41223",
    "datePublished": "2022-11-22T00:00:00.000Z",
    "dateReserved": "2022-09-21T00:00:00.000Z",
    "dateUpdated": "2025-10-21T23:15:30.959Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-29499 (GCVE-0-2022-29499)
Vulnerability from cvelistv5
Published
2022-04-26 01:13
Modified
2025-10-21 23:15
Severity ?
CWE
  • n/a
Summary
The Service Appliance component in Mitel MiVoice Connect through 19.2 SP3 allows remote code execution because of incorrect data validation. The Service Appliances are SA 100, SA 400, and Virtual SA.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:26:06.067Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-22-0002"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-29499",
                "options": [
                  {
                    "Exploitation": "active"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-29T16:10:59.913484Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          },
          {
            "other": {
              "content": {
                "dateAdded": "2022-06-27",
                "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2022-29499"
              },
              "type": "kev"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-20",
                "description": "CWE-20 Improper Input Validation",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-21T23:15:40.565Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "government-resource"
            ],
            "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2022-29499"
          }
        ],
        "timeline": [
          {
            "lang": "en",
            "time": "2022-06-27T00:00:00+00:00",
            "value": "CVE-2022-29499 added to CISA KEV"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The Service Appliance component in Mitel MiVoice Connect through 19.2 SP3 allows remote code execution because of incorrect data validation. The Service Appliances are SA 100, SA 400, and Virtual SA."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-26T01:13:58.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-22-0002"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-29499",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The Service Appliance component in Mitel MiVoice Connect through 19.2 SP3 allows remote code execution because of incorrect data validation. The Service Appliances are SA 100, SA 400, and Virtual SA."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-22-0002",
              "refsource": "CONFIRM",
              "url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-22-0002"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-29499",
    "datePublished": "2022-04-26T01:13:58.000Z",
    "dateReserved": "2022-04-19T00:00:00.000Z",
    "dateUpdated": "2025-10-21T23:15:40.565Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}