Vulnerabilites related to northern.tech - mender
CVE-2024-46948 (GCVE-0-2024-46948)
Vulnerability from cvelistv5
Published
2024-11-08 00:00
Modified
2025-02-10 22:21
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Northern.tech Mender before 3.6.5 and 3.7.x before 3.7.5 has Incorrect Access Control.
References
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-46948", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-11-08T18:37:45.895795Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-284", "description": "CWE-284 Improper Access Control", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-10T22:21:56.130Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Northern.tech Mender before 3.6.5 and 3.7.x before 3.7.5 has Incorrect Access Control." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-08T15:48:07.600Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://mender.io/blog/cve-2024-46948" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-46948", "datePublished": "2024-11-08T00:00:00.000Z", "dateReserved": "2024-09-15T00:00:00.000Z", "dateUpdated": "2025-02-10T22:21:56.130Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-35342 (GCVE-0-2021-35342)
Vulnerability from cvelistv5
Published
2021-08-27 09:52
Modified
2024-08-04 00:33
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
The useradm service 1.14.0 (in Northern.tech Mender Enterprise 2.7.x before 2.7.1) and 1.13.0 (in Northern.tech Mender Enterprise 2.6.x before 2.6.1) allows users to access the system with their JWT token after logout, because of missing invalidation (if the JWT verification cache is enabled).
References
▼ | URL | Tags |
---|---|---|
https://northern.tech/our-products | x_refsource_MISC | |
https://mender.io/blog/cve-2021-35342-useradm-logout-vulnerabililty | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T00:33:51.312Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://northern.tech/our-products" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://mender.io/blog/cve-2021-35342-useradm-logout-vulnerabililty" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "The useradm service 1.14.0 (in Northern.tech Mender Enterprise 2.7.x before 2.7.1) and 1.13.0 (in Northern.tech Mender Enterprise 2.6.x before 2.6.1) allows users to access the system with their JWT token after logout, because of missing invalidation (if the JWT verification cache is enabled)." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-08-27T09:52:16", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://northern.tech/our-products" }, { "tags": [ "x_refsource_MISC" ], "url": "https://mender.io/blog/cve-2021-35342-useradm-logout-vulnerabililty" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-35342", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The useradm service 1.14.0 (in Northern.tech Mender Enterprise 2.7.x before 2.7.1) and 1.13.0 (in Northern.tech Mender Enterprise 2.6.x before 2.6.1) allows users to access the system with their JWT token after logout, because of missing invalidation (if the JWT verification cache is enabled)." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://northern.tech/our-products", "refsource": "MISC", "url": "https://northern.tech/our-products" }, { "name": "https://mender.io/blog/cve-2021-35342-useradm-logout-vulnerabililty", "refsource": "MISC", "url": "https://mender.io/blog/cve-2021-35342-useradm-logout-vulnerabililty" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-35342", "datePublished": "2021-08-27T09:52:16", "dateReserved": "2021-06-23T00:00:00", "dateUpdated": "2024-08-04T00:33:51.312Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-29556 (GCVE-0-2022-29556)
Vulnerability from cvelistv5
Published
2022-04-28 19:48
Modified
2024-08-03 06:26
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
The iot-manager microservice 1.0.0 in Northern.tech Mender Enterprise before 3.2.2 allows SSRF because the Azure IoT Hub integration provides several SSRF primitives that can execute cross-tenant actions via internal API endpoints.
References
▼ | URL | Tags |
---|---|---|
https://northern.tech | x_refsource_MISC | |
https://mender.io/blog/cve-2022-29555-and-cve-2022-29556-vulnerabilities-in-iot-manager-and-deviceconnect | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T06:26:06.303Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://northern.tech" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://mender.io/blog/cve-2022-29555-and-cve-2022-29556-vulnerabilities-in-iot-manager-and-deviceconnect" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "The iot-manager microservice 1.0.0 in Northern.tech Mender Enterprise before 3.2.2 allows SSRF because the Azure IoT Hub integration provides several SSRF primitives that can execute cross-tenant actions via internal API endpoints." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-28T19:48:39", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://northern.tech" }, { "tags": [ "x_refsource_MISC" ], "url": "https://mender.io/blog/cve-2022-29555-and-cve-2022-29556-vulnerabilities-in-iot-manager-and-deviceconnect" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-29556", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The iot-manager microservice 1.0.0 in Northern.tech Mender Enterprise before 3.2.2 allows SSRF because the Azure IoT Hub integration provides several SSRF primitives that can execute cross-tenant actions via internal API endpoints." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://northern.tech", "refsource": "MISC", "url": "https://northern.tech" }, { "name": "https://mender.io/blog/cve-2022-29555-and-cve-2022-29556-vulnerabilities-in-iot-manager-and-deviceconnect", "refsource": "MISC", "url": "https://mender.io/blog/cve-2022-29555-and-cve-2022-29556-vulnerabilities-in-iot-manager-and-deviceconnect" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-29556", "datePublished": "2022-04-28T19:48:39", "dateReserved": "2022-04-21T00:00:00", "dateUpdated": "2024-08-03T06:26:06.303Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-32290 (GCVE-0-2022-32290)
Vulnerability from cvelistv5
Published
2022-07-06 11:12
Modified
2024-08-03 07:39
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
The client in Northern.tech Mender 3.2.0, 3.2.1, and 3.2.2 has Incorrect Access Control. It listens on a random, unprivileged TCP port and exposes an HTTP proxy to facilitate API calls from additional client components running on the device. However, it listens on all network interfaces instead of only the localhost interface. Therefore, any client on the same network can connect to this TCP port and send HTTP requests. The Mender Client will forward these requests to the Mender Server. Additionally, if mTLS is set up, the Mender Client will connect to the Mender Server using the device's client certificate, making it possible for the attacker to bypass mTLS authentication and send requests to the Mender Server without direct access to the client certificate and related private key. Accessing the HTTP proxy from the local network doesn't represent a direct threat, because it doesn't expose any device or server-specific data. However, it increases the attack surface and can be a potential vector to exploit other vulnerabilities both on the Client and the Server.
References
▼ | URL | Tags |
---|---|---|
https://northern.tech | x_refsource_MISC | |
https://mender.io/blog/cve-2022-32290-mender-client-listening-on-all-the-interfaces | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:39:50.385Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://northern.tech" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://mender.io/blog/cve-2022-32290-mender-client-listening-on-all-the-interfaces" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "The client in Northern.tech Mender 3.2.0, 3.2.1, and 3.2.2 has Incorrect Access Control. It listens on a random, unprivileged TCP port and exposes an HTTP proxy to facilitate API calls from additional client components running on the device. However, it listens on all network interfaces instead of only the localhost interface. Therefore, any client on the same network can connect to this TCP port and send HTTP requests. The Mender Client will forward these requests to the Mender Server. Additionally, if mTLS is set up, the Mender Client will connect to the Mender Server using the device\u0027s client certificate, making it possible for the attacker to bypass mTLS authentication and send requests to the Mender Server without direct access to the client certificate and related private key. Accessing the HTTP proxy from the local network doesn\u0027t represent a direct threat, because it doesn\u0027t expose any device or server-specific data. However, it increases the attack surface and can be a potential vector to exploit other vulnerabilities both on the Client and the Server." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-07-06T11:12:55", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://northern.tech" }, { "tags": [ "x_refsource_MISC" ], "url": "https://mender.io/blog/cve-2022-32290-mender-client-listening-on-all-the-interfaces" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-32290", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The client in Northern.tech Mender 3.2.0, 3.2.1, and 3.2.2 has Incorrect Access Control. It listens on a random, unprivileged TCP port and exposes an HTTP proxy to facilitate API calls from additional client components running on the device. However, it listens on all network interfaces instead of only the localhost interface. Therefore, any client on the same network can connect to this TCP port and send HTTP requests. The Mender Client will forward these requests to the Mender Server. Additionally, if mTLS is set up, the Mender Client will connect to the Mender Server using the device\u0027s client certificate, making it possible for the attacker to bypass mTLS authentication and send requests to the Mender Server without direct access to the client certificate and related private key. Accessing the HTTP proxy from the local network doesn\u0027t represent a direct threat, because it doesn\u0027t expose any device or server-specific data. However, it increases the attack surface and can be a potential vector to exploit other vulnerabilities both on the Client and the Server." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://northern.tech", "refsource": "MISC", "url": "https://northern.tech" }, { "name": "https://mender.io/blog/cve-2022-32290-mender-client-listening-on-all-the-interfaces", "refsource": "MISC", "url": "https://mender.io/blog/cve-2022-32290-mender-client-listening-on-all-the-interfaces" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-32290", "datePublished": "2022-07-06T11:12:55", "dateReserved": "2022-06-05T00:00:00", "dateUpdated": "2024-08-03T07:39:50.385Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-29555 (GCVE-0-2022-29555)
Vulnerability from cvelistv5
Published
2022-04-28 19:44
Modified
2024-08-03 06:26
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
The Deviceconnect microservice through 1.3.0 in Northern.tech Mender Enterprise before 3.2.2. allows Cross-Origin Websocket Hijacking.
References
▼ | URL | Tags |
---|---|---|
https://northern.tech | x_refsource_MISC | |
https://mender.io/blog/cve-2022-29555-and-cve-2022-29556-vulnerabilities-in-iot-manager-and-deviceconnect | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T06:26:06.100Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://northern.tech" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://mender.io/blog/cve-2022-29555-and-cve-2022-29556-vulnerabilities-in-iot-manager-and-deviceconnect" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "The Deviceconnect microservice through 1.3.0 in Northern.tech Mender Enterprise before 3.2.2. allows Cross-Origin Websocket Hijacking." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-28T19:44:49", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://northern.tech" }, { "tags": [ "x_refsource_MISC" ], "url": "https://mender.io/blog/cve-2022-29555-and-cve-2022-29556-vulnerabilities-in-iot-manager-and-deviceconnect" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-29555", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The Deviceconnect microservice through 1.3.0 in Northern.tech Mender Enterprise before 3.2.2. allows Cross-Origin Websocket Hijacking." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://northern.tech", "refsource": "MISC", "url": "https://northern.tech" }, { "name": "https://mender.io/blog/cve-2022-29555-and-cve-2022-29556-vulnerabilities-in-iot-manager-and-deviceconnect", "refsource": "MISC", "url": "https://mender.io/blog/cve-2022-29555-and-cve-2022-29556-vulnerabilities-in-iot-manager-and-deviceconnect" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-29555", "datePublished": "2022-04-28T19:44:49", "dateReserved": "2022-04-21T00:00:00", "dateUpdated": "2024-08-03T06:26:06.100Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2022-07-06 12:15
Modified
2024-11-21 07:06
Severity ?
Summary
The client in Northern.tech Mender 3.2.0, 3.2.1, and 3.2.2 has Incorrect Access Control. It listens on a random, unprivileged TCP port and exposes an HTTP proxy to facilitate API calls from additional client components running on the device. However, it listens on all network interfaces instead of only the localhost interface. Therefore, any client on the same network can connect to this TCP port and send HTTP requests. The Mender Client will forward these requests to the Mender Server. Additionally, if mTLS is set up, the Mender Client will connect to the Mender Server using the device's client certificate, making it possible for the attacker to bypass mTLS authentication and send requests to the Mender Server without direct access to the client certificate and related private key. Accessing the HTTP proxy from the local network doesn't represent a direct threat, because it doesn't expose any device or server-specific data. However, it increases the attack surface and can be a potential vector to exploit other vulnerabilities both on the Client and the Server.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
northern.tech | mender | 3.2.0 | |
northern.tech | mender | 3.2.1 | |
northern.tech | mender | 3.2.2 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:northern.tech:mender:3.2.0:*:*:*:-:*:*:*", "matchCriteriaId": "7E2B5205-6FC8-400A-A8DE-837F70BF32A3", "vulnerable": true }, { "criteria": "cpe:2.3:a:northern.tech:mender:3.2.1:*:*:*:-:*:*:*", "matchCriteriaId": "CE7227EA-E3FD-49CC-8456-FFFAF873298B", "vulnerable": true }, { "criteria": "cpe:2.3:a:northern.tech:mender:3.2.2:*:*:*:-:*:*:*", "matchCriteriaId": "3C4F33C7-2496-4EA2-A953-27198737906E", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "The client in Northern.tech Mender 3.2.0, 3.2.1, and 3.2.2 has Incorrect Access Control. It listens on a random, unprivileged TCP port and exposes an HTTP proxy to facilitate API calls from additional client components running on the device. However, it listens on all network interfaces instead of only the localhost interface. Therefore, any client on the same network can connect to this TCP port and send HTTP requests. The Mender Client will forward these requests to the Mender Server. Additionally, if mTLS is set up, the Mender Client will connect to the Mender Server using the device\u0027s client certificate, making it possible for the attacker to bypass mTLS authentication and send requests to the Mender Server without direct access to the client certificate and related private key. Accessing the HTTP proxy from the local network doesn\u0027t represent a direct threat, because it doesn\u0027t expose any device or server-specific data. However, it increases the attack surface and can be a potential vector to exploit other vulnerabilities both on the Client and the Server." }, { "lang": "es", "value": "El cliente de Northern.tech Mender versiones 3.2.0, 3.2.1 y 3.2.2, presenta un Control de Acceso Incorrecto. Escucha en un puerto TCP aleatorio y no privilegiado y expone un proxy HTTP para facilitar las llamadas a la API desde componentes adicionales del cliente que se ejecutan en el dispositivo. Sin embargo, escucha en todas las interfaces de red en lugar de s\u00f3lo en la interfaz localhost. Por lo tanto, cualquier cliente en la misma red puede conectarse a este puerto TCP y enviar peticiones HTTP. El Cliente Mender reenviar\u00e1 estas peticiones al Servidor Mender. Adem\u00e1s, si mTLS est\u00e1 configurado, el Cliente Prestador ser\u00e1 conectado al Servidor Prestador usando el certificado de cliente del dispositivo, lo que hace posible a el atacante omitir la autenticaci\u00f3n mTLS y env\u00ede peticiones al Servidor Prestador sin acceso directo al certificado del cliente y a la clave privada relacionada. El acceso al proxy HTTP desde la red local no representa una amenaza directa, porque no expone ning\u00fan dato espec\u00edfico del dispositivo o del servidor. Sin embargo, aumenta la superficie de ataque y puede ser un vector potencial para explotar otras vulnerabilidades tanto en el Cliente como en el Servidor" } ], "id": "CVE-2022-32290", "lastModified": "2024-11-21T07:06:06.787", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 1.4, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-07-06T12:15:08.227", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://mender.io/blog/cve-2022-32290-mender-client-listening-on-all-the-interfaces" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://northern.tech" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://mender.io/blog/cve-2022-32290-mender-client-listening-on-all-the-interfaces" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://northern.tech" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-863" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-04-28 20:15
Modified
2024-11-21 06:59
Severity ?
Summary
The iot-manager microservice 1.0.0 in Northern.tech Mender Enterprise before 3.2.2 allows SSRF because the Azure IoT Hub integration provides several SSRF primitives that can execute cross-tenant actions via internal API endpoints.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
northern.tech | mender | 3.2.0 | |
northern.tech | mender | 3.2.1 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:northern.tech:mender:3.2.0:*:*:*:*:enterprise:*:*", "matchCriteriaId": "11332043-72ED-439B-BB00-9A4A5B59990B", "vulnerable": true }, { "criteria": "cpe:2.3:a:northern.tech:mender:3.2.1:*:*:*:*:enterprise:*:*", "matchCriteriaId": "C2AA3CCD-EA28-491C-845A-675D830EE49C", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "The iot-manager microservice 1.0.0 in Northern.tech Mender Enterprise before 3.2.2 allows SSRF because the Azure IoT Hub integration provides several SSRF primitives that can execute cross-tenant actions via internal API endpoints." }, { "lang": "es", "value": "El microservicio iot-manager versi\u00f3n 1.0.0 en Northern.tech Mender Enterprise versiones anteriores a 3.2.2 permite un ataque de tipo SSRF porque la integraci\u00f3n Azure IoT Hub proporciona varias primitivas SSRF que pueden ejecutar acciones cross-tenant por medio de endpoints API internos" } ], "id": "CVE-2022-29556", "lastModified": "2024-11-21T06:59:18.750", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-04-28T20:15:08.100", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://mender.io/blog/cve-2022-29555-and-cve-2022-29556-vulnerabilities-in-iot-manager-and-deviceconnect" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://northern.tech" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://mender.io/blog/cve-2022-29555-and-cve-2022-29556-vulnerabilities-in-iot-manager-and-deviceconnect" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://northern.tech" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-918" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-11-08 16:15
Modified
2025-02-10 23:15
Severity ?
4.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N
5.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
5.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
Summary
Northern.tech Mender before 3.6.5 and 3.7.x before 3.7.5 has Incorrect Access Control.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://mender.io/blog/cve-2024-46948 | Patch, Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
northern.tech | mender | * | |
northern.tech | mender | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:northern.tech:mender:*:*:*:*:-:*:*:*", "matchCriteriaId": "B3A7CEEA-0832-4491-A03E-65CC94E00C52", "versionEndExcluding": "3.6.5", "vulnerable": true }, { "criteria": "cpe:2.3:a:northern.tech:mender:*:*:*:*:-:*:*:*", "matchCriteriaId": "B3D2470F-F8D3-46DC-8128-DAA557C21D80", "versionEndExcluding": "3.7.5", "versionStartIncluding": "3.7.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Northern.tech Mender before 3.6.5 and 3.7.x before 3.7.5 has Incorrect Access Control." }, { "lang": "es", "value": "Northern.tech Mender anterior a 3.6.5 y 3.7.x anterior a 3.7.5 tiene un control de acceso incorrecto." } ], "id": "CVE-2024-46948", "lastModified": "2025-02-10T23:15:14.720", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 1.4, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 1.4, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2024-11-08T16:15:24.050", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://mender.io/blog/cve-2024-46948" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-284" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2022-04-28 20:15
Modified
2024-11-21 06:59
Severity ?
Summary
The Deviceconnect microservice through 1.3.0 in Northern.tech Mender Enterprise before 3.2.2. allows Cross-Origin Websocket Hijacking.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
northern.tech | mender | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:northern.tech:mender:*:*:*:*:enterprise:*:*:*", "matchCriteriaId": "70C25524-6CA4-46AC-86BD-A085E857042D", "versionEndExcluding": "3.2.2", "versionStartIncluding": "2.6.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "The Deviceconnect microservice through 1.3.0 in Northern.tech Mender Enterprise before 3.2.2. allows Cross-Origin Websocket Hijacking." }, { "lang": "es", "value": "El microservicio Deviceconnect versiones hasta 1.3.0 en Northern.tech Mender Enterprise versiones anteriores a 3.2.2. permite un secuestro de Websocket de Origen Cruzado" } ], "id": "CVE-2022-29555", "lastModified": "2024-11-21T06:59:18.587", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-04-28T20:15:08.060", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://mender.io/blog/cve-2022-29555-and-cve-2022-29556-vulnerabilities-in-iot-manager-and-deviceconnect" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://northern.tech" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://mender.io/blog/cve-2022-29555-and-cve-2022-29556-vulnerabilities-in-iot-manager-and-deviceconnect" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://northern.tech" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-352" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-08-27 10:15
Modified
2024-11-21 06:12
Severity ?
Summary
The useradm service 1.14.0 (in Northern.tech Mender Enterprise 2.7.x before 2.7.1) and 1.13.0 (in Northern.tech Mender Enterprise 2.6.x before 2.6.1) allows users to access the system with their JWT token after logout, because of missing invalidation (if the JWT verification cache is enabled).
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://mender.io/blog/cve-2021-35342-useradm-logout-vulnerabililty | Third Party Advisory | |
cve@mitre.org | https://northern.tech/our-products | Product, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://mender.io/blog/cve-2021-35342-useradm-logout-vulnerabililty | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://northern.tech/our-products | Product, Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
northern.tech | useradm | 1.14.0 | |
northern.tech | mender | * | |
northern.tech | useradm | 1.13.0 | |
northern.tech | mender | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:northern.tech:useradm:1.14.0:*:*:*:*:*:*:*", "matchCriteriaId": "46BCE564-E41F-422F-BFC2-1FF88A393D11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:a:northern.tech:mender:*:*:*:*:enterprise:*:*:*", "matchCriteriaId": "83AF3BB0-3080-4EE1-9F9A-337E414B798E", "versionEndExcluding": "2.7.1", "versionStartIncluding": "2.7.0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:northern.tech:useradm:1.13.0:*:*:*:*:*:*:*", "matchCriteriaId": "49F6A945-43B7-48F3-99C5-7844FBB5F918", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:a:northern.tech:mender:*:*:*:*:enterprise:*:*:*", "matchCriteriaId": "26B635AD-C1E0-464B-BE13-3CFBB9282B35", "versionEndExcluding": "2.6.1", "versionStartIncluding": "2.6.0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "The useradm service 1.14.0 (in Northern.tech Mender Enterprise 2.7.x before 2.7.1) and 1.13.0 (in Northern.tech Mender Enterprise 2.6.x before 2.6.1) allows users to access the system with their JWT token after logout, because of missing invalidation (if the JWT verification cache is enabled)." }, { "lang": "es", "value": "El servicio useradm versiones 1.14.0 (en Northern.tech Mender Enterprise 2.7.x versiones anteriores a 2.7.1) y 1.13.0 (en Northern.tech Mender Enterprise 2.6.x versiones anteriores a 2.6.1) permite a usuarios acceder al sistema con su token JWT despu\u00e9s de cerrar la sesi\u00f3n, debido a una falta de no comprobaci\u00f3n (si la cach\u00e9 de comprobaci\u00f3n JWT est\u00e1 habilitada)." } ], "id": "CVE-2021-35342", "lastModified": "2024-11-21T06:12:14.570", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-08-27T10:15:07.793", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://mender.io/blog/cve-2021-35342-useradm-logout-vulnerabililty" }, { "source": "cve@mitre.org", "tags": [ "Product", "Vendor Advisory" ], "url": "https://northern.tech/our-products" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://mender.io/blog/cve-2021-35342-useradm-logout-vulnerabililty" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Product", "Vendor Advisory" ], "url": "https://northern.tech/our-products" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-613" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }