Refine your search
18 vulnerabilities found for mbNET.mini by MB connect line
CVE-2025-41681 (GCVE-0-2025-41681)
Vulnerability from nvd
Published
2025-07-21 09:31
Modified
2025-11-03 19:59
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Summary
A high privileged remote attacker can gain persistent XSS via POST requests due to improper neutralization of special elements used to create dynamic content.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MB connect line | mbNET.mini |
Version: 0.0.0 ≤ |
||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41681",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-21T12:30:26.217066Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T12:30:37.772Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:59:07.270Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/38"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX 100",
"vendor": "Helmholz",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A high privileged remote attacker can gain persistent XSS via POST requests due to improper neutralization of special elements used to create dynamic content.\u003cbr\u003e"
}
],
"value": "A high privileged remote attacker can gain persistent XSS via POST requests due to improper neutralization of special elements used to create dynamic content."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T09:31:25.796Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2025-058"
}
],
"source": {
"advisory": "VDE-2025-058, VDE-2025-059",
"defect": [
"CERT@VDE#641816",
"CERT@VDE#641817"
],
"discovery": "UNKNOWN"
},
"title": "Persistent Cross-Site Scripting via POST Requests Due to Improper Neutralization of Input",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41681",
"datePublished": "2025-07-21T09:31:25.796Z",
"dateReserved": "2025-04-16T11:17:48.308Z",
"dateUpdated": "2025-11-03T19:59:07.270Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41679 (GCVE-0-2025-41679)
Vulnerability from nvd
Published
2025-07-21 09:31
Modified
2025-11-03 19:59
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-787 - Out-of-bounds Write
Summary
An unauthenticated remote attacker could exploit a buffer overflow vulnerability in the device causing a denial of service that affects only the network initializing wizard (Conftool) service.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MB connect line | mbNET.mini |
Version: 0.0.0 ≤ |
||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41679",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-21T12:30:59.892256Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T12:31:24.437Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:59:05.914Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/38"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX 100",
"vendor": "Helmholz",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker could exploit a buffer overflow vulnerability in the device causing a denial of service that affects only the network initializing wizard (Conftool) service.\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker could exploit a buffer overflow vulnerability in the device causing a denial of service that affects only the network initializing wizard (Conftool) service."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T09:31:04.713Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2025-058"
}
],
"source": {
"advisory": "VDE-2025-058, VDE-2025-059",
"defect": [
"CERT@VDE#641816",
"CERT@VDE#641817"
],
"discovery": "UNKNOWN"
},
"title": "Unauthenticated Buffer Overflow in Conftool Service Leading to Denial of Service",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41679",
"datePublished": "2025-07-21T09:31:04.713Z",
"dateReserved": "2025-04-16T11:17:48.308Z",
"dateUpdated": "2025-11-03T19:59:05.914Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41678 (GCVE-0-2025-41678)
Vulnerability from nvd
Published
2025-07-21 09:30
Modified
2025-11-03 19:59
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A high privileged remote attacker can alter the configuration database via POST requests due to improper neutralization of special elements used in a SQL statement.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MB connect line | mbNET.mini |
Version: 0.0.0 ≤ |
||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41678",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-21T12:32:03.780398Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T12:32:09.542Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:59:04.559Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/38"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX 100",
"vendor": "Helmholz",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A high privileged remote attacker can alter the configuration database via POST requests due to improper neutralization of special elements used in a SQL statement.\u003cbr\u003e"
}
],
"value": "A high privileged remote attacker can alter the configuration database via POST requests due to improper neutralization of special elements used in a SQL statement."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T09:30:44.484Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2025-058"
}
],
"source": {
"advisory": "VDE-2025-058, VDE-2025-059",
"defect": [
"CERT@VDE#641816",
"CERT@VDE#641817"
],
"discovery": "UNKNOWN"
},
"title": "SQL Injection via POST Requests Allowing Configuration Database Manipulation",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41678",
"datePublished": "2025-07-21T09:30:44.484Z",
"dateReserved": "2025-04-16T11:17:48.308Z",
"dateUpdated": "2025-11-03T19:59:04.559Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41677 (GCVE-0-2025-41677)
Vulnerability from nvd
Published
2025-07-21 09:30
Modified
2025-11-03 19:59
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-400 - Uncontrolled Resource Consumption
Summary
A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-mail action in fast succession.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MB connect line | mbNET.mini |
Version: 0.0.0 ≤ |
||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41677",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-21T15:00:24.440243Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T20:36:33.574Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:59:03.144Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/38"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX 100",
"vendor": "Helmholz",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-mail action in fast succession.\u003cbr\u003e"
}
],
"value": "A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-mail action in fast succession."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400 Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T09:30:28.614Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2025-058"
}
],
"source": {
"advisory": "VDE-2025-058, VDE-2025-059",
"defect": [
"CERT@VDE#641816",
"CERT@VDE#641817"
],
"discovery": "UNKNOWN"
},
"title": "Resource Exhaustion via POST Requests to send-mail Action",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41677",
"datePublished": "2025-07-21T09:30:28.614Z",
"dateReserved": "2025-04-16T11:17:48.308Z",
"dateUpdated": "2025-11-03T19:59:03.144Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41676 (GCVE-0-2025-41676)
Vulnerability from nvd
Published
2025-07-21 09:30
Modified
2025-11-03 19:59
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-400 - Uncontrolled Resource Consumption
Summary
A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-sms action in fast succession.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MB connect line | mbNET.mini |
Version: 0.0.0 ≤ |
||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41676",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-21T15:00:32.085015Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T20:36:39.497Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:59:01.738Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/38"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX 100",
"vendor": "Helmholz",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-sms action in fast succession.\u003cbr\u003e"
}
],
"value": "A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-sms action in fast succession."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400 Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T09:30:07.473Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2025-058"
}
],
"source": {
"advisory": "VDE-2025-058, VDE-2025-059",
"defect": [
"CERT@VDE#641816",
"CERT@VDE#641817"
],
"discovery": "UNKNOWN"
},
"title": "Resource Exhaustion via POST Requests to send-sms Action",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41676",
"datePublished": "2025-07-21T09:30:07.473Z",
"dateReserved": "2025-04-16T11:17:48.308Z",
"dateUpdated": "2025-11-03T19:59:01.738Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41675 (GCVE-0-2025-41675)
Vulnerability from nvd
Published
2025-07-21 09:29
Modified
2025-11-03 19:59
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Summary
A high privileged remote attacker can execute arbitrary system commands via GET requests in the cloud server communication script due to improper neutralization of special elements used in an OS command.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MB connect line | mbNET.mini |
Version: 0.0.0 ≤ |
||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41675",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-21T15:00:42.591445Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T20:36:45.460Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:59:00.344Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/38"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX 100",
"vendor": "Helmholz",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A high privileged remote attacker can execute arbitrary system commands via GET requests in the cloud server communication script due to improper neutralization of special elements used in an OS command.\u003cbr\u003e"
}
],
"value": "A high privileged remote attacker can execute arbitrary system commands via GET requests in the cloud server communication script due to improper neutralization of special elements used in an OS command."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T09:29:57.024Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2025-058"
}
],
"source": {
"advisory": "VDE-2025-058, VDE-2025-059",
"defect": [
"CERT@VDE#641816",
"CERT@VDE#641817"
],
"discovery": "UNKNOWN"
},
"title": "Remote Command Injection via GET in Cloud Server Communication Script Due to Improper Input Neutralization",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41675",
"datePublished": "2025-07-21T09:29:57.024Z",
"dateReserved": "2025-04-16T11:17:48.308Z",
"dateUpdated": "2025-11-03T19:59:00.344Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41674 (GCVE-0-2025-41674)
Vulnerability from nvd
Published
2025-07-21 09:29
Modified
2025-11-03 19:58
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Summary
A high privileged remote attacker can execute arbitrary system commands via POST requests in the diagnostic action due to improper neutralization of special elements used in an OS command.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MB connect line | mbNET.mini |
Version: 0.0.0 ≤ |
||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41674",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-21T17:04:43.501527Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T17:05:33.656Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:58:58.776Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/38"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX 100",
"vendor": "Helmholz",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A high privileged remote attacker can execute arbitrary system commands via POST requests in the diagnostic action due to improper neutralization of special elements used in an OS command.\u003cbr\u003e"
}
],
"value": "A high privileged remote attacker can execute arbitrary system commands via POST requests in the diagnostic action due to improper neutralization of special elements used in an OS command."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T09:29:43.181Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2025-058"
}
],
"source": {
"advisory": "VDE-2025-058, VDE-2025-059",
"defect": [
"CERT@VDE#641816",
"CERT@VDE#641817"
],
"discovery": "UNKNOWN"
},
"title": "Remote Command Injection in diagnostic Action Due to Improper Input Neutralization",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41674",
"datePublished": "2025-07-21T09:29:43.181Z",
"dateReserved": "2025-04-16T11:17:48.308Z",
"dateUpdated": "2025-11-03T19:58:58.776Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41673 (GCVE-0-2025-41673)
Vulnerability from nvd
Published
2025-07-21 09:29
Modified
2025-11-03 19:58
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Summary
A high privileged remote attacker can execute arbitrary system commands via POST requests in the send_sms action due to improper neutralization of special elements used in an OS command.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MB connect line | mbNET.mini |
Version: 0.0.0 ≤ |
||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41673",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-21T17:05:45.438732Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T17:06:11.768Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:58:57.413Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/38"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX 100",
"vendor": "Helmholz",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A high privileged remote attacker can execute arbitrary system commands via POST requests in the send_sms action due to improper neutralization of special elements used in an OS command.\u003cbr\u003e"
}
],
"value": "A high privileged remote attacker can execute arbitrary system commands via POST requests in the send_sms action due to improper neutralization of special elements used in an OS command."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T09:29:32.129Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2025-058"
}
],
"source": {
"advisory": "VDE-2025-058, VDE-2025-059",
"defect": [
"CERT@VDE#641816",
"CERT@VDE#641817"
],
"discovery": "UNKNOWN"
},
"title": "Remote Command Injection in send_sms Action Due to Improper Input Neutralization",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41673",
"datePublished": "2025-07-21T09:29:32.129Z",
"dateReserved": "2025-04-16T11:17:48.308Z",
"dateUpdated": "2025-11-03T19:58:57.413Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-45274 (GCVE-0-2024-45274)
Vulnerability from nvd
Published
2024-10-15 10:28
Modified
2025-11-03 19:30
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-306 - Missing Authentication for Critical Function
Summary
An unauthenticated remote attacker can execute OS commands via UDP on the device due to missing authentication.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MB connect line | mbNET.mini |
Version: 0.0.0 ≤ 2.2.13 |
||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "mbnet.mini",
"vendor": "mb_connect_line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "rex_100_firmware",
"vendor": "helmholz",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "mbnet.mini",
"vendor": "mb_connect_line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "rex_100_firmware",
"vendor": "helmholz",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-45274",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-15T13:33:38.579567Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-15T13:34:58.690Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:30:51.547Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-063.txt"
},
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/38"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX100",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Moritz Abrell"
},
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "SySS GmbH"
}
],
"datePublic": "2024-10-15T08:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker can execute OS commands via UDP on the device due to missing authentication.\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker can execute OS commands via UDP on the device due to missing authentication."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-15T10:28:16.384Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-056"
},
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-066"
}
],
"source": {
"advisory": "VDE-2024-056, VDE-2024-066",
"defect": [
"CERT@VDE#641679",
"CERT@VDE#641692"
],
"discovery": "UNKNOWN"
},
"title": "MB connect line/Helmholz: Remote code execution via confnet service",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2024-45274",
"datePublished": "2024-10-15T10:28:16.384Z",
"dateReserved": "2024-08-26T09:19:01.266Z",
"dateUpdated": "2025-11-03T19:30:51.547Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41681 (GCVE-0-2025-41681)
Vulnerability from cvelistv5
Published
2025-07-21 09:31
Modified
2025-11-03 19:59
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Summary
A high privileged remote attacker can gain persistent XSS via POST requests due to improper neutralization of special elements used to create dynamic content.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MB connect line | mbNET.mini |
Version: 0.0.0 ≤ |
||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41681",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-21T12:30:26.217066Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T12:30:37.772Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:59:07.270Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/38"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX 100",
"vendor": "Helmholz",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A high privileged remote attacker can gain persistent XSS via POST requests due to improper neutralization of special elements used to create dynamic content.\u003cbr\u003e"
}
],
"value": "A high privileged remote attacker can gain persistent XSS via POST requests due to improper neutralization of special elements used to create dynamic content."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T09:31:25.796Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2025-058"
}
],
"source": {
"advisory": "VDE-2025-058, VDE-2025-059",
"defect": [
"CERT@VDE#641816",
"CERT@VDE#641817"
],
"discovery": "UNKNOWN"
},
"title": "Persistent Cross-Site Scripting via POST Requests Due to Improper Neutralization of Input",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41681",
"datePublished": "2025-07-21T09:31:25.796Z",
"dateReserved": "2025-04-16T11:17:48.308Z",
"dateUpdated": "2025-11-03T19:59:07.270Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41679 (GCVE-0-2025-41679)
Vulnerability from cvelistv5
Published
2025-07-21 09:31
Modified
2025-11-03 19:59
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-787 - Out-of-bounds Write
Summary
An unauthenticated remote attacker could exploit a buffer overflow vulnerability in the device causing a denial of service that affects only the network initializing wizard (Conftool) service.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MB connect line | mbNET.mini |
Version: 0.0.0 ≤ |
||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41679",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-21T12:30:59.892256Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T12:31:24.437Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:59:05.914Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/38"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX 100",
"vendor": "Helmholz",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker could exploit a buffer overflow vulnerability in the device causing a denial of service that affects only the network initializing wizard (Conftool) service.\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker could exploit a buffer overflow vulnerability in the device causing a denial of service that affects only the network initializing wizard (Conftool) service."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T09:31:04.713Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2025-058"
}
],
"source": {
"advisory": "VDE-2025-058, VDE-2025-059",
"defect": [
"CERT@VDE#641816",
"CERT@VDE#641817"
],
"discovery": "UNKNOWN"
},
"title": "Unauthenticated Buffer Overflow in Conftool Service Leading to Denial of Service",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41679",
"datePublished": "2025-07-21T09:31:04.713Z",
"dateReserved": "2025-04-16T11:17:48.308Z",
"dateUpdated": "2025-11-03T19:59:05.914Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41678 (GCVE-0-2025-41678)
Vulnerability from cvelistv5
Published
2025-07-21 09:30
Modified
2025-11-03 19:59
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A high privileged remote attacker can alter the configuration database via POST requests due to improper neutralization of special elements used in a SQL statement.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MB connect line | mbNET.mini |
Version: 0.0.0 ≤ |
||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41678",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-21T12:32:03.780398Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T12:32:09.542Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:59:04.559Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/38"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX 100",
"vendor": "Helmholz",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A high privileged remote attacker can alter the configuration database via POST requests due to improper neutralization of special elements used in a SQL statement.\u003cbr\u003e"
}
],
"value": "A high privileged remote attacker can alter the configuration database via POST requests due to improper neutralization of special elements used in a SQL statement."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T09:30:44.484Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2025-058"
}
],
"source": {
"advisory": "VDE-2025-058, VDE-2025-059",
"defect": [
"CERT@VDE#641816",
"CERT@VDE#641817"
],
"discovery": "UNKNOWN"
},
"title": "SQL Injection via POST Requests Allowing Configuration Database Manipulation",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41678",
"datePublished": "2025-07-21T09:30:44.484Z",
"dateReserved": "2025-04-16T11:17:48.308Z",
"dateUpdated": "2025-11-03T19:59:04.559Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41677 (GCVE-0-2025-41677)
Vulnerability from cvelistv5
Published
2025-07-21 09:30
Modified
2025-11-03 19:59
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-400 - Uncontrolled Resource Consumption
Summary
A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-mail action in fast succession.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MB connect line | mbNET.mini |
Version: 0.0.0 ≤ |
||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41677",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-21T15:00:24.440243Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T20:36:33.574Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:59:03.144Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/38"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX 100",
"vendor": "Helmholz",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-mail action in fast succession.\u003cbr\u003e"
}
],
"value": "A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-mail action in fast succession."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400 Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T09:30:28.614Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2025-058"
}
],
"source": {
"advisory": "VDE-2025-058, VDE-2025-059",
"defect": [
"CERT@VDE#641816",
"CERT@VDE#641817"
],
"discovery": "UNKNOWN"
},
"title": "Resource Exhaustion via POST Requests to send-mail Action",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41677",
"datePublished": "2025-07-21T09:30:28.614Z",
"dateReserved": "2025-04-16T11:17:48.308Z",
"dateUpdated": "2025-11-03T19:59:03.144Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41676 (GCVE-0-2025-41676)
Vulnerability from cvelistv5
Published
2025-07-21 09:30
Modified
2025-11-03 19:59
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-400 - Uncontrolled Resource Consumption
Summary
A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-sms action in fast succession.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MB connect line | mbNET.mini |
Version: 0.0.0 ≤ |
||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41676",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-21T15:00:32.085015Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T20:36:39.497Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:59:01.738Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/38"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX 100",
"vendor": "Helmholz",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-sms action in fast succession.\u003cbr\u003e"
}
],
"value": "A high privileged remote attacker can exhaust critical system resources by sending specifically crafted POST requests to the send-sms action in fast succession."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400 Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T09:30:07.473Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2025-058"
}
],
"source": {
"advisory": "VDE-2025-058, VDE-2025-059",
"defect": [
"CERT@VDE#641816",
"CERT@VDE#641817"
],
"discovery": "UNKNOWN"
},
"title": "Resource Exhaustion via POST Requests to send-sms Action",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41676",
"datePublished": "2025-07-21T09:30:07.473Z",
"dateReserved": "2025-04-16T11:17:48.308Z",
"dateUpdated": "2025-11-03T19:59:01.738Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41675 (GCVE-0-2025-41675)
Vulnerability from cvelistv5
Published
2025-07-21 09:29
Modified
2025-11-03 19:59
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Summary
A high privileged remote attacker can execute arbitrary system commands via GET requests in the cloud server communication script due to improper neutralization of special elements used in an OS command.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MB connect line | mbNET.mini |
Version: 0.0.0 ≤ |
||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41675",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-21T15:00:42.591445Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T20:36:45.460Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:59:00.344Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/38"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX 100",
"vendor": "Helmholz",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A high privileged remote attacker can execute arbitrary system commands via GET requests in the cloud server communication script due to improper neutralization of special elements used in an OS command.\u003cbr\u003e"
}
],
"value": "A high privileged remote attacker can execute arbitrary system commands via GET requests in the cloud server communication script due to improper neutralization of special elements used in an OS command."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T09:29:57.024Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2025-058"
}
],
"source": {
"advisory": "VDE-2025-058, VDE-2025-059",
"defect": [
"CERT@VDE#641816",
"CERT@VDE#641817"
],
"discovery": "UNKNOWN"
},
"title": "Remote Command Injection via GET in Cloud Server Communication Script Due to Improper Input Neutralization",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41675",
"datePublished": "2025-07-21T09:29:57.024Z",
"dateReserved": "2025-04-16T11:17:48.308Z",
"dateUpdated": "2025-11-03T19:59:00.344Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41674 (GCVE-0-2025-41674)
Vulnerability from cvelistv5
Published
2025-07-21 09:29
Modified
2025-11-03 19:58
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Summary
A high privileged remote attacker can execute arbitrary system commands via POST requests in the diagnostic action due to improper neutralization of special elements used in an OS command.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MB connect line | mbNET.mini |
Version: 0.0.0 ≤ |
||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41674",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-21T17:04:43.501527Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T17:05:33.656Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:58:58.776Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/38"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX 100",
"vendor": "Helmholz",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A high privileged remote attacker can execute arbitrary system commands via POST requests in the diagnostic action due to improper neutralization of special elements used in an OS command.\u003cbr\u003e"
}
],
"value": "A high privileged remote attacker can execute arbitrary system commands via POST requests in the diagnostic action due to improper neutralization of special elements used in an OS command."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T09:29:43.181Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2025-058"
}
],
"source": {
"advisory": "VDE-2025-058, VDE-2025-059",
"defect": [
"CERT@VDE#641816",
"CERT@VDE#641817"
],
"discovery": "UNKNOWN"
},
"title": "Remote Command Injection in diagnostic Action Due to Improper Input Neutralization",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41674",
"datePublished": "2025-07-21T09:29:43.181Z",
"dateReserved": "2025-04-16T11:17:48.308Z",
"dateUpdated": "2025-11-03T19:58:58.776Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41673 (GCVE-0-2025-41673)
Vulnerability from cvelistv5
Published
2025-07-21 09:29
Modified
2025-11-03 19:58
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Summary
A high privileged remote attacker can execute arbitrary system commands via POST requests in the send_sms action due to improper neutralization of special elements used in an OS command.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MB connect line | mbNET.mini |
Version: 0.0.0 ≤ |
||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41673",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-21T17:05:45.438732Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T17:06:11.768Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:58:57.413Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/38"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX 100",
"vendor": "Helmholz",
"versions": [
{
"lessThan": "2.3.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "F. Bruckmoser, M. Eder, J. Heigl, M. Heudorn, G. Hofmarcher, M. Kadlec, M. Pristauz-Telsnigg, S. Resch, P. Schweinzer, M. Gschiel from St. Poelten UAS"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A high privileged remote attacker can execute arbitrary system commands via POST requests in the send_sms action due to improper neutralization of special elements used in an OS command.\u003cbr\u003e"
}
],
"value": "A high privileged remote attacker can execute arbitrary system commands via POST requests in the send_sms action due to improper neutralization of special elements used in an OS command."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T09:29:32.129Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2025-058"
}
],
"source": {
"advisory": "VDE-2025-058, VDE-2025-059",
"defect": [
"CERT@VDE#641816",
"CERT@VDE#641817"
],
"discovery": "UNKNOWN"
},
"title": "Remote Command Injection in send_sms Action Due to Improper Input Neutralization",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41673",
"datePublished": "2025-07-21T09:29:32.129Z",
"dateReserved": "2025-04-16T11:17:48.308Z",
"dateUpdated": "2025-11-03T19:58:57.413Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-45274 (GCVE-0-2024-45274)
Vulnerability from cvelistv5
Published
2024-10-15 10:28
Modified
2025-11-03 19:30
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-306 - Missing Authentication for Critical Function
Summary
An unauthenticated remote attacker can execute OS commands via UDP on the device due to missing authentication.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| MB connect line | mbNET.mini |
Version: 0.0.0 ≤ 2.2.13 |
||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "mbnet.mini",
"vendor": "mb_connect_line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "rex_100_firmware",
"vendor": "helmholz",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "mbnet.mini",
"vendor": "mb_connect_line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "rex_100_firmware",
"vendor": "helmholz",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-45274",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-15T13:33:38.579567Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-15T13:34:58.690Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:30:51.547Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-063.txt"
},
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/38"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX100",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Moritz Abrell"
},
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "SySS GmbH"
}
],
"datePublic": "2024-10-15T08:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker can execute OS commands via UDP on the device due to missing authentication.\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker can execute OS commands via UDP on the device due to missing authentication."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-15T10:28:16.384Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-056"
},
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-066"
}
],
"source": {
"advisory": "VDE-2024-056, VDE-2024-066",
"defect": [
"CERT@VDE#641679",
"CERT@VDE#641692"
],
"discovery": "UNKNOWN"
},
"title": "MB connect line/Helmholz: Remote code execution via confnet service",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2024-45274",
"datePublished": "2024-10-15T10:28:16.384Z",
"dateReserved": "2024-08-26T09:19:01.266Z",
"dateUpdated": "2025-11-03T19:30:51.547Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}