Refine your search
2 vulnerabilities found for mMedica by Asseco Poland S.A.
CVE-2025-9313 (GCVE-0-2025-9313)
Vulnerability from nvd
Published
2025-10-28 11:49
Modified
2025-10-28 13:15
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-288 - Authentication Bypass Using an Alternate Path or Channel
Summary
An unauthenticated user can connect to a publicly accessible database using arbitrary credentials. The system grants full access to the database by leveraging a previously authenticated connection through a "mmBackup" application. This flaw allows attackers to bypass authentication mechanisms and gain unauthorized access to database with sensitive data.
This issue affects Asseco mMedica in versions before 11.9.5.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Asseco Poland S.A. | mMedica |
Version: 0 < 11.9.5 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-9313",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-28T13:15:10.082135Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-28T13:15:31.459Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mMedica",
"vendor": "Asseco Poland S.A.",
"versions": [
{
"lessThan": "11.9.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated user can connect to a publicly accessible database using arbitrary credentials. The system grants full access to the database by leveraging a previously authenticated connection through a \"mmBackup\" application. This flaw allows attackers to bypass authentication mechanisms and gain unauthorized access to database with sensitive data.\u003cbr\u003e\u003cbr\u003eThis issue affects Asseco mMedica in versions before 11.9.5."
}
],
"value": "An unauthenticated user can connect to a publicly accessible database using arbitrary credentials. The system grants full access to the database by leveraging a previously authenticated connection through a \"mmBackup\" application. This flaw allows attackers to bypass authentication mechanisms and gain unauthorized access to database with sensitive data.\n\nThis issue affects Asseco mMedica in versions before 11.9.5."
}
],
"impacts": [
{
"capecId": "CAPEC-115",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-115 Authentication Bypass"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-288",
"description": "CWE-288: Authentication Bypass Using an Alternate Path or Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-28T11:49:29.119Z",
"orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"shortName": "CERT-PL"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://cert.pl/en/posts/2025/10/CVE-2025-9313/"
},
{
"tags": [
"product"
],
"url": "https://mmedica.asseco.pl/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Unauthorized database access in Asseco mMedica",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"assignerShortName": "CERT-PL",
"cveId": "CVE-2025-9313",
"datePublished": "2025-10-28T11:49:29.119Z",
"dateReserved": "2025-08-21T07:29:05.144Z",
"dateUpdated": "2025-10-28T13:15:31.459Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-9313 (GCVE-0-2025-9313)
Vulnerability from cvelistv5
Published
2025-10-28 11:49
Modified
2025-10-28 13:15
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-288 - Authentication Bypass Using an Alternate Path or Channel
Summary
An unauthenticated user can connect to a publicly accessible database using arbitrary credentials. The system grants full access to the database by leveraging a previously authenticated connection through a "mmBackup" application. This flaw allows attackers to bypass authentication mechanisms and gain unauthorized access to database with sensitive data.
This issue affects Asseco mMedica in versions before 11.9.5.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Asseco Poland S.A. | mMedica |
Version: 0 < 11.9.5 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-9313",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-28T13:15:10.082135Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-28T13:15:31.459Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mMedica",
"vendor": "Asseco Poland S.A.",
"versions": [
{
"lessThan": "11.9.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated user can connect to a publicly accessible database using arbitrary credentials. The system grants full access to the database by leveraging a previously authenticated connection through a \"mmBackup\" application. This flaw allows attackers to bypass authentication mechanisms and gain unauthorized access to database with sensitive data.\u003cbr\u003e\u003cbr\u003eThis issue affects Asseco mMedica in versions before 11.9.5."
}
],
"value": "An unauthenticated user can connect to a publicly accessible database using arbitrary credentials. The system grants full access to the database by leveraging a previously authenticated connection through a \"mmBackup\" application. This flaw allows attackers to bypass authentication mechanisms and gain unauthorized access to database with sensitive data.\n\nThis issue affects Asseco mMedica in versions before 11.9.5."
}
],
"impacts": [
{
"capecId": "CAPEC-115",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-115 Authentication Bypass"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-288",
"description": "CWE-288: Authentication Bypass Using an Alternate Path or Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-28T11:49:29.119Z",
"orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"shortName": "CERT-PL"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://cert.pl/en/posts/2025/10/CVE-2025-9313/"
},
{
"tags": [
"product"
],
"url": "https://mmedica.asseco.pl/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Unauthorized database access in Asseco mMedica",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"assignerShortName": "CERT-PL",
"cveId": "CVE-2025-9313",
"datePublished": "2025-10-28T11:49:29.119Z",
"dateReserved": "2025-08-21T07:29:05.144Z",
"dateUpdated": "2025-10-28T13:15:31.459Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",