Vulnerabilites related to dlink - go-rt-ac750_firmware
Vulnerability from fkie_nvd
Published
2024-01-16 22:15
Modified
2024-11-21 08:56
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
In D-LINK Go-RT-AC750 v101b03, the sprintf function in the sub_40E700 function within the cgibin is susceptible to stack overflow.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://kee02p.github.io/2024/01/13/CVE-2024-22916/ | Exploit, Third Party Advisory | |
cve@mitre.org | https://www.dlink.com/en/security-bulletin/ | Product | |
af854a3a-2127-422b-91ae-364da2661108 | https://kee02p.github.io/2024/01/13/CVE-2024-22916/ | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.dlink.com/en/security-bulletin/ | Product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
dlink | go-rt-ac750_firmware | 101b03 | |
dlink | go-rt-ac750 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:101b03:*:*:*:*:*:*:*", "matchCriteriaId": "11857770-E809-483A-993F-1C827428B334", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:go-rt-ac750:-:*:*:*:*:*:*:*", "matchCriteriaId": "EE067003-B0B5-4419-8BB3-A31C015276D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "In D-LINK Go-RT-AC750 v101b03, the sprintf function in the sub_40E700 function within the cgibin is susceptible to stack overflow." }, { "lang": "es", "value": "En D-LINK Go-RT-AC750 v101b03, la funci\u00f3n sprintf en la funci\u00f3n sub_40E700 dentro de cgibin es susceptible al desbordamiento de pila." } ], "id": "CVE-2024-22916", "lastModified": "2024-11-21T08:56:47.923", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2024-01-16T22:15:46.613", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://kee02p.github.io/2024/01/13/CVE-2024-22916/" }, { "source": "cve@mitre.org", "tags": [ "Product" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://kee02p.github.io/2024/01/13/CVE-2024-22916/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Product" ], "url": "https://www.dlink.com/en/security-bulletin/" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-02-06 02:15
Modified
2025-06-20 21:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
D-LINK Go-RT-AC750 GORTAC750_A1_FW_v101b03 has a hardcoded password for the Alphanetworks account, which allows remote attackers to obtain root access via a telnet session.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/2/2.md | Exploit, Third Party Advisory | |
cve@mitre.org | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/2/2.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
dlink | go-rt-ac750_firmware | 101b03 | |
dlink | go-rt-ac750 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:101b03:*:*:*:*:*:*:*", "matchCriteriaId": "11857770-E809-483A-993F-1C827428B334", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:go-rt-ac750:-:*:*:*:*:*:*:*", "matchCriteriaId": "EE067003-B0B5-4419-8BB3-A31C015276D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "D-LINK Go-RT-AC750 GORTAC750_A1_FW_v101b03 has a hardcoded password for the Alphanetworks account, which allows remote attackers to obtain root access via a telnet session." }, { "lang": "es", "value": "D-LINK Go-RT-AC750 GORTAC750_A1_FW_v101b03 tiene una contrase\u00f1a codificada para la cuenta Alphanetworks, que permite a atacantes remotos obtener acceso root a trav\u00e9s de una sesi\u00f3n de telnet." } ], "id": "CVE-2024-22853", "lastModified": "2025-06-20T21:15:21.023", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2024-02-06T02:15:08.757", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/2/2.md" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/2/2.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.dlink.com/en/security-bulletin/" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-798" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-798" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2023-04-01 23:15
Modified
2025-02-11 18:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at soapcgi.main.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/yzskyt/Vuln/blob/main/Go-RT-AC750/Go-RT-AC750.md | Exploit, Third Party Advisory | |
cve@mitre.org | https://www.dlink.com/en/security-bulletin/ | Not Applicable | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/yzskyt/Vuln/blob/main/Go-RT-AC750/Go-RT-AC750.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.dlink.com/en/security-bulletin/ | Not Applicable |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
dlink | go-rt-ac750_firmware | reva_v101b03 | |
dlink | go-rt-ac750 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:reva_v101b03:*:*:*:*:*:*:*", "matchCriteriaId": "BF67C4BB-000A-4657-9BA0-8DC944AC20B3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:go-rt-ac750:-:*:*:*:*:*:*:*", "matchCriteriaId": "EE067003-B0B5-4419-8BB3-A31C015276D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at soapcgi.main." } ], "id": "CVE-2023-26822", "lastModified": "2025-02-11T18:15:24.467", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-04-01T23:15:07.060", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/yzskyt/Vuln/blob/main/Go-RT-AC750/Go-RT-AC750.md" }, { "source": "cve@mitre.org", "tags": [ "Not Applicable" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/yzskyt/Vuln/blob/main/Go-RT-AC750/Go-RT-AC750.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Not Applicable" ], "url": "https://www.dlink.com/en/security-bulletin/" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2022-08-28 17:15
Modified
2025-01-06 15:15
Severity ?
Summary
D-Link Go-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 are vulnerable to Buffer Overflow via cgibin, hnap_main,
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://drive.google.com/file/d/1hmIk0jQoex4QDyjIUg_6yxi-J6ROCh8S/view?usp=sharing | Exploit, Patch, Third Party Advisory | |
cve@mitre.org | https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10308 | ||
cve@mitre.org | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://drive.google.com/file/d/1hmIk0jQoex4QDyjIUg_6yxi-J6ROCh8S/view?usp=sharing | Exploit, Patch, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
dlink | go-rt-ac750_firmware | reva_1.01b03 | |
dlink | go-rt-ac750_firmware | revb_2.00b02 | |
dlink | go-rt-ac750 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:reva_1.01b03:*:*:*:*:*:*:*", "matchCriteriaId": "1B975BD2-5567-4B7A-BC8D-633B5D446556", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:revb_2.00b02:*:*:*:*:*:*:*", "matchCriteriaId": "26C39776-31C6-498B-91C4-2CAB0EEFFEBF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:go-rt-ac750:-:*:*:*:*:*:*:*", "matchCriteriaId": "EE067003-B0B5-4419-8BB3-A31C015276D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "D-Link Go-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 are vulnerable to Buffer Overflow via cgibin, hnap_main," }, { "lang": "es", "value": "D-Link Go-RT-AC750 versiones GORTAC750_revA_v101b03 y GO-RT-AC750_revB_FWv200b02, son vulnerables al desbordamiento del b\u00fafer por medio de cgibin, hnap_main," } ], "id": "CVE-2022-37055", "lastModified": "2025-01-06T15:15:09.830", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-08-28T17:15:08.363", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Patch", "Third Party Advisory" ], "url": "https://drive.google.com/file/d/1hmIk0jQoex4QDyjIUg_6yxi-J6ROCh8S/view?usp=sharing" }, { "source": "cve@mitre.org", "url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10308" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Patch", "Third Party Advisory" ], "url": "https://drive.google.com/file/d/1hmIk0jQoex4QDyjIUg_6yxi-J6ROCh8S/view?usp=sharing" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.dlink.com/en/security-bulletin/" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-08-15 17:15
Modified
2024-11-21 07:13
Severity ?
Summary
D-Link Go-RT-AC750 GORTAC750_revA_v101b03 & GO-RT-AC750_revB_FWv200b02 is vulnerable to command injection via /htdocs/upnpinc/gena.php.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://drive.google.com/file/d/13D6K0UxNNzbLU4YRPfJc7MAk6iKFICdr/view?usp=sharing | Broken Link, Third Party Advisory | |
cve@mitre.org | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://drive.google.com/file/d/13D6K0UxNNzbLU4YRPfJc7MAk6iKFICdr/view?usp=sharing | Broken Link, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
dlink | go-rt-ac750_firmware | 101b03 | |
dlink | go-rt-ac750 | revision_a | |
dlink | go-rt-ac750_firmware | 200b02 | |
dlink | go-rt-ac750 | revision_b |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:101b03:*:*:*:*:*:*:*", "matchCriteriaId": "11857770-E809-483A-993F-1C827428B334", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:go-rt-ac750:revision_a:*:*:*:*:*:*:*", "matchCriteriaId": "426BE281-6336-4A4E-892B-CE8BBCA8ABF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:200b02:*:*:*:*:*:*:*", "matchCriteriaId": "E610B4D9-198B-4986-89CC-F3C75DBC3EF3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:go-rt-ac750:revision_b:*:*:*:*:*:*:*", "matchCriteriaId": "5F4EF05A-EF25-4E60-8A08-9C0CDD9244EF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "D-Link Go-RT-AC750 GORTAC750_revA_v101b03 \u0026 GO-RT-AC750_revB_FWv200b02 is vulnerable to command injection via /htdocs/upnpinc/gena.php." }, { "lang": "es", "value": "D-Link Go-RT-AC750 versiones GORTAC750_revA_v101b03 \u0026amp; GO-RT-AC750_revB_FWv200b02 son vulnerables a una inyecci\u00f3n de comandos por medio del archivo /htdocs/upnpinc/gena.php." } ], "id": "CVE-2022-36523", "lastModified": "2024-11-21T07:13:13.590", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-08-15T17:15:13.550", "references": [ { "source": "cve@mitre.org", "tags": [ "Broken Link", "Third Party Advisory" ], "url": "https://drive.google.com/file/d/13D6K0UxNNzbLU4YRPfJc7MAk6iKFICdr/view?usp=sharing" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link", "Third Party Advisory" ], "url": "https://drive.google.com/file/d/13D6K0UxNNzbLU4YRPfJc7MAk6iKFICdr/view?usp=sharing" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.dlink.com/en/security-bulletin/" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-02-06 02:15
Modified
2025-05-15 20:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contains a stack-based buffer overflow via the function genacgi_main. This vulnerability allows attackers to enable telnet service via a specially crafted payload.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/1/1.md | Exploit, Third Party Advisory | |
cve@mitre.org | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/1/1.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
dlink | go-rt-ac750_firmware | 101b03 | |
dlink | go-rt-ac750 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:101b03:*:*:*:*:*:*:*", "matchCriteriaId": "11857770-E809-483A-993F-1C827428B334", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:go-rt-ac750:-:*:*:*:*:*:*:*", "matchCriteriaId": "EE067003-B0B5-4419-8BB3-A31C015276D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contains a stack-based buffer overflow via the function genacgi_main. This vulnerability allows attackers to enable telnet service via a specially crafted payload." }, { "lang": "es", "value": "D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contiene un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria a trav\u00e9s de la funci\u00f3n genacgi_main. Esta vulnerabilidad permite a los atacantes habilitar el servicio telnet a trav\u00e9s de un payload especialmente manipulado." } ], "id": "CVE-2024-22852", "lastModified": "2025-05-15T20:15:43.533", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2024-02-06T02:15:08.663", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/1/1.md" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/1/1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.dlink.com/en/security-bulletin/" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2022-08-28 17:15
Modified
2025-01-09 18:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
D-Link GO-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 is vulnerable to Command Injection via /cgibin, hnap_main,
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing | Exploit, Patch, Third Party Advisory | |
cve@mitre.org | https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10308 | ||
cve@mitre.org | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing | Exploit, Patch, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
dlink | go-rt-ac750_firmware | reva_1.01b03 | |
dlink | go-rt-ac750_firmware | revb_2.00b02 | |
dlink | go-rt-ac750 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:reva_1.01b03:*:*:*:*:*:*:*", "matchCriteriaId": "1B975BD2-5567-4B7A-BC8D-633B5D446556", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:revb_2.00b02:*:*:*:*:*:*:*", "matchCriteriaId": "26C39776-31C6-498B-91C4-2CAB0EEFFEBF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:go-rt-ac750:-:*:*:*:*:*:*:*", "matchCriteriaId": "EE067003-B0B5-4419-8BB3-A31C015276D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "D-Link GO-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 is vulnerable to Command Injection via /cgibin, hnap_main," }, { "lang": "es", "value": "D-Link GO-RT-AC750 versiones GORTAC750_revA_v101b03 y GO-RT-AC750_revB_FWv200b02, son vulnerables a una inyecci\u00f3n de comandos por medio de /cgibin, hnap_main," } ], "id": "CVE-2022-37056", "lastModified": "2025-01-09T18:15:24.797", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2022-08-28T17:15:08.413", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Patch", "Third Party Advisory" ], "url": "https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing" }, { "source": "cve@mitre.org", "url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10308" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Patch", "Third Party Advisory" ], "url": "https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.dlink.com/en/security-bulletin/" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "cve@mitre.org", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-12-01 16:15
Modified
2025-06-03 03:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at hedwig.cgi.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
dlink | go-rt-ac750_firmware | 101b03 | |
dlink | go-rt-ac750 | revision_a |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:101b03:*:*:*:*:*:*:*", "matchCriteriaId": "11857770-E809-483A-993F-1C827428B334", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:go-rt-ac750:revision_a:*:*:*:*:*:*:*", "matchCriteriaId": "426BE281-6336-4A4E-892B-CE8BBCA8ABF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at hedwig.cgi." }, { "lang": "es", "value": "Se descubri\u00f3 que D-Link Go-RT-AC750 revA_v101b03 conten\u00eda una vulnerabilidad de inyecci\u00f3n de comandos a trav\u00e9s del par\u00e1metro de servicio en hedwig.cgi." } ], "id": "CVE-2023-48842", "lastModified": "2025-06-03T03:15:25.490", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-12-01T16:15:07.550", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit" ], "url": "https://drive.google.com/file/d/1y5om__f2SAhNmcPqDxC_SRTvJVAWwPcH/view?usp=drive_link" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit" ], "url": "https://drive.google.com/file/d/1y5om__f2SAhNmcPqDxC_SRTvJVAWwPcH/view?usp=drive_link" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2022-08-15 17:15
Modified
2024-11-21 07:13
Severity ?
Summary
D-Link GO-RT-AC750 GORTAC750_revA_v101b03 & GO-RT-AC750_revB_FWv200b02 is vulnerable to Authentication Bypass via function phpcgi_main in cgibin.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | http://d-link.com | Broken Link, Product | |
cve@mitre.org | https://drive.google.com/file/d/1ji5Ph6c-qgp0lBvbY8BZJjeqbju3VeK8/view?usp=sharing | Broken Link, Third Party Advisory | |
cve@mitre.org | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://d-link.com | Broken Link, Product | |
af854a3a-2127-422b-91ae-364da2661108 | https://drive.google.com/file/d/1ji5Ph6c-qgp0lBvbY8BZJjeqbju3VeK8/view?usp=sharing | Broken Link, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
dlink | go-rt-ac750_firmware | 101b03 | |
dlink | go-rt-ac750 | revision_a | |
dlink | go-rt-ac750_firmware | 200b02 | |
dlink | go-rt-ac750 | revision_b |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:101b03:*:*:*:*:*:*:*", "matchCriteriaId": "11857770-E809-483A-993F-1C827428B334", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:go-rt-ac750:revision_a:*:*:*:*:*:*:*", "matchCriteriaId": "426BE281-6336-4A4E-892B-CE8BBCA8ABF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:200b02:*:*:*:*:*:*:*", "matchCriteriaId": "E610B4D9-198B-4986-89CC-F3C75DBC3EF3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:go-rt-ac750:revision_b:*:*:*:*:*:*:*", "matchCriteriaId": "5F4EF05A-EF25-4E60-8A08-9C0CDD9244EF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "D-Link GO-RT-AC750 GORTAC750_revA_v101b03 \u0026 GO-RT-AC750_revB_FWv200b02 is vulnerable to Authentication Bypass via function phpcgi_main in cgibin." }, { "lang": "es", "value": "D-Link GO-RT-AC750 versiones GORTAC750_revA_v101b03 \u0026amp; GO-RT-AC750_revB_FWv200b02 son vulnerables a una omisi\u00f3n de autenticaci\u00f3n por medio de la funci\u00f3n phpcgi_main en cgibin." } ], "id": "CVE-2022-36526", "lastModified": "2024-11-21T07:13:14.090", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-08-15T17:15:14.000", "references": [ { "source": "cve@mitre.org", "tags": [ "Broken Link", "Product" ], "url": "http://d-link.com" }, { "source": "cve@mitre.org", "tags": [ "Broken Link", "Third Party Advisory" ], "url": "https://drive.google.com/file/d/1ji5Ph6c-qgp0lBvbY8BZJjeqbju3VeK8/view?usp=sharing" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link", "Product" ], "url": "http://d-link.com" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link", "Third Party Advisory" ], "url": "https://drive.google.com/file/d/1ji5Ph6c-qgp0lBvbY8BZJjeqbju3VeK8/view?usp=sharing" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.dlink.com/en/security-bulletin/" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-06-15 21:15
Modified
2024-12-16 20:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at genacgi_main.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/Tyaoo/IoT-Vuls/blob/main/dlink/Go-RT-AC750/vul.md | Exploit, Third Party Advisory | |
cve@mitre.org | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/Tyaoo/IoT-Vuls/blob/main/dlink/Go-RT-AC750/vul.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
dlink | go-rt-ac750_firmware | reva_1.01b03 | |
dlink | go-rt-ac750 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:reva_1.01b03:*:*:*:*:*:*:*", "matchCriteriaId": "1B975BD2-5567-4B7A-BC8D-633B5D446556", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:go-rt-ac750:-:*:*:*:*:*:*:*", "matchCriteriaId": "EE067003-B0B5-4419-8BB3-A31C015276D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at genacgi_main." }, { "lang": "es", "value": "Se descubri\u00f3 que D-Link Go-RT-AC750 revA_v101b03 contiene una vulnerabilidad de inyecci\u00f3n de comandos a trav\u00e9s del par\u00e1metro service en genacgi_main." } ], "id": "CVE-2023-34800", "lastModified": "2024-12-16T20:15:07.120", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-06-15T21:15:09.677", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Tyaoo/IoT-Vuls/blob/main/dlink/Go-RT-AC750/vul.md" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Tyaoo/IoT-Vuls/blob/main/dlink/Go-RT-AC750/vul.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.dlink.com/en/security-bulletin/" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2022-08-28 16:15
Modified
2025-01-06 15:15
Severity ?
Summary
D-Link Go-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 are vulnerable to Command Injection via cgibin, ssdpcgi_main.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://drive.google.com/file/d/1_UUpraFTxxB97ujrgVLQZXQ8Q8M58BAF/view?usp=sharing | Exploit, Patch, Third Party Advisory | |
cve@mitre.org | https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10308 | ||
cve@mitre.org | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://drive.google.com/file/d/1_UUpraFTxxB97ujrgVLQZXQ8Q8M58BAF/view?usp=sharing | Exploit, Patch, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
dlink | go-rt-ac750_firmware | reva_1.01b03 | |
dlink | go-rt-ac750_firmware | revb_2.00b02 | |
dlink | go-rt-ac750 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:reva_1.01b03:*:*:*:*:*:*:*", "matchCriteriaId": "1B975BD2-5567-4B7A-BC8D-633B5D446556", "vulnerable": true }, { "criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:revb_2.00b02:*:*:*:*:*:*:*", "matchCriteriaId": "26C39776-31C6-498B-91C4-2CAB0EEFFEBF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:go-rt-ac750:-:*:*:*:*:*:*:*", "matchCriteriaId": "EE067003-B0B5-4419-8BB3-A31C015276D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "D-Link Go-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 are vulnerable to Command Injection via cgibin, ssdpcgi_main." }, { "lang": "es", "value": "D-Link Go-RT-AC750 versiones GORTAC750_revA_v101b03 y GO-RT-AC750_revB_FWv200b02, son vulnerables a una Inyecci\u00f3n de Comandos por medio de cgibin, ssdpcgi_main." } ], "id": "CVE-2022-37057", "lastModified": "2025-01-06T15:15:10.147", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-08-28T16:15:09.123", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Patch", "Third Party Advisory" ], "url": "https://drive.google.com/file/d/1_UUpraFTxxB97ujrgVLQZXQ8Q8M58BAF/view?usp=sharing" }, { "source": "cve@mitre.org", "url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10308" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Patch", "Third Party Advisory" ], "url": "https://drive.google.com/file/d/1_UUpraFTxxB97ujrgVLQZXQ8Q8M58BAF/view?usp=sharing" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.dlink.com/en/security-bulletin/" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-04-11 01:25
Modified
2025-06-17 20:55
Severity ?
Summary
D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contains a stack-based buffer overflow via the function hnap_main. An attacker can send a POST request to trigger the vulnerablilify.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
dlink | go-rt-ac750_firmware | 101b03 | |
dlink | go-rt-ac750 | a1 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:101b03:*:*:*:*:*:*:*", "matchCriteriaId": "11857770-E809-483A-993F-1C827428B334", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:go-rt-ac750:a1:*:*:*:*:*:*:*", "matchCriteriaId": "FD359363-0BD0-49DF-99B3-1F6A2CED8378", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contains a stack-based buffer overflow via the function hnap_main. An attacker can send a POST request to trigger the vulnerablilify." }, { "lang": "es", "value": "D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contiene un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria a trav\u00e9s de la funci\u00f3n hnap_main. Un atacante puede enviar una solicitud POST para activar la vulnerabilidad." } ], "id": "CVE-2024-27683", "lastModified": "2025-06-17T20:55:49.377", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2024-04-11T01:25:05.340", "references": [ { "source": "cve@mitre.org", "tags": [ "Permissions Required" ], "url": "https://drive.google.com/file/d/18RhbBnaD_kH16Y6C-7TpSSPUmYKKyU_k/view" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://gist.github.com/sunwithmoon/428c3871482a600382fec0a1994a518b" }, { "source": "cve@mitre.org", "tags": [ "Product" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required" ], "url": "https://drive.google.com/file/d/18RhbBnaD_kH16Y6C-7TpSSPUmYKKyU_k/view" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://gist.github.com/sunwithmoon/428c3871482a600382fec0a1994a518b" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Product" ], "url": "https://www.dlink.com/en/security-bulletin/" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2022-08-15 17:15
Modified
2024-11-21 07:13
Severity ?
Summary
D-Link Go-RT-AC750 GORTAC750_revA_v101b03 & GO-RT-AC750_revB_FWv200b02 is vulnerable to Buffer Overflow via authenticationcgi_main.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://drive.google.com/file/d/1IGtqvX2y-8GIwBsK6yi04AGfIzAXXvzW/view?usp=sharing | Broken Link, Third Party Advisory | |
cve@mitre.org | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://drive.google.com/file/d/1IGtqvX2y-8GIwBsK6yi04AGfIzAXXvzW/view?usp=sharing | Broken Link, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
dlink | go-rt-ac750_firmware | 101b03 | |
dlink | go-rt-ac750 | - | |
dlink | go-rt-ac750 | reva | |
dlink | go-rt-ac750_firmware | 200b02 | |
dlink | go-rt-ac750 | revb |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:101b03:*:*:*:*:*:*:*", "matchCriteriaId": "11857770-E809-483A-993F-1C827428B334", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:go-rt-ac750:-:*:*:*:*:*:*:*", "matchCriteriaId": "EE067003-B0B5-4419-8BB3-A31C015276D0", "vulnerable": false }, { "criteria": "cpe:2.3:h:dlink:go-rt-ac750:reva:*:*:*:*:*:*:*", "matchCriteriaId": "2AB3F3F5-2366-4595-B094-42479CB93123", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:200b02:*:*:*:*:*:*:*", "matchCriteriaId": "E610B4D9-198B-4986-89CC-F3C75DBC3EF3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:go-rt-ac750:revb:*:*:*:*:*:*:*", "matchCriteriaId": "E9C83939-49B1-4B4A-AB14-CCD8233DFE80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "D-Link Go-RT-AC750 GORTAC750_revA_v101b03 \u0026 GO-RT-AC750_revB_FWv200b02 is vulnerable to Buffer Overflow via authenticationcgi_main." }, { "lang": "es", "value": "D-Link Go-RT-AC750 versiones GORTAC750_revA_v101b03 \u0026amp; GO-RT-AC750_revB_FWv200b02 son vulnerables al desbordamiento del b\u00fafer por medio de la funci\u00f3n authenticationcgi_main." } ], "id": "CVE-2022-36525", "lastModified": "2024-11-21T07:13:13.920", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-08-15T17:15:13.920", "references": [ { "source": "cve@mitre.org", "tags": [ "Broken Link", "Third Party Advisory" ], "url": "https://drive.google.com/file/d/1IGtqvX2y-8GIwBsK6yi04AGfIzAXXvzW/view?usp=sharing" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link", "Third Party Advisory" ], "url": "https://drive.google.com/file/d/1IGtqvX2y-8GIwBsK6yi04AGfIzAXXvzW/view?usp=sharing" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.dlink.com/en/security-bulletin/" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-04 14:15
Modified
2025-05-02 19:32
Severity ?
Summary
A Cross-site scripting (XSS) vulnerability in dlapn.cgi, dldongle.cgi, dlcfg.cgi, fwup.cgi and seama.cgi in D-Link GORTAC750_A1_FW_v101b03 allows remote attackers to inject arbitrary web script or HTML via the url parameter.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
dlink | go-rt-ac750_firmware | 101b03 | |
dlink | go-rt-ac750 | a1 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:101b03:*:*:*:*:*:*:*", "matchCriteriaId": "11857770-E809-483A-993F-1C827428B334", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:go-rt-ac750:a1:*:*:*:*:*:*:*", "matchCriteriaId": "FD359363-0BD0-49DF-99B3-1F6A2CED8378", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A Cross-site scripting (XSS) vulnerability in dlapn.cgi, dldongle.cgi, dlcfg.cgi, fwup.cgi and seama.cgi in D-Link GORTAC750_A1_FW_v101b03 allows remote attackers to inject arbitrary web script or HTML via the url parameter." }, { "lang": "es", "value": "Una vulnerabilidad de Cross-Site Scripting (XSS) en dlapn.cgi, dldongle.cgi, dlcfg.cgi, fwup.cgi y seama.cgi en D-Link GORTAC750_A1_FW_v101b03 permite a atacantes remotos inyectar script web o HTML arbitrarios a trav\u00e9s del par\u00e1metro url." } ], "id": "CVE-2024-27684", "lastModified": "2025-05-02T19:32:50.587", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 2.7, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2024-03-04T14:15:41.587", "references": [ { "source": "cve@mitre.org", "tags": [ "Permissions Required" ], "url": "https://drive.google.com/file/d/1qu4iBQGeAwolTXjVOTXsAAusSHo2ie-Y/view" }, { "source": "cve@mitre.org", "tags": [ "Product" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required" ], "url": "https://drive.google.com/file/d/1qu4iBQGeAwolTXjVOTXsAAusSHo2ie-Y/view" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Product" ], "url": "https://www.dlink.com/en/security-bulletin/" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2022-08-15 17:15
Modified
2024-11-21 07:13
Severity ?
Summary
D-Link GO-RT-AC750 GORTAC750_revA_v101b03 & GO-RT-AC750_revB_FWv200b02 is vulnerable to Static Default Credentials via /etc/init0.d/S80telnetd.sh.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | http://d-link.com | Broken Link, Product | |
cve@mitre.org | https://drive.google.com/file/d/1WNKrDUbYfSWbSve9ONILkLY6dbM8I7hh/view?usp=sharing | Broken Link, Third Party Advisory | |
cve@mitre.org | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://d-link.com | Broken Link, Product | |
af854a3a-2127-422b-91ae-364da2661108 | https://drive.google.com/file/d/1WNKrDUbYfSWbSve9ONILkLY6dbM8I7hh/view?usp=sharing | Broken Link, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
dlink | go-rt-ac750_firmware | 101b03 | |
dlink | go-rt-ac750 | revision_a | |
dlink | go-rt-ac750_firmware | 200b02 | |
dlink | go-rt-ac750 | revision_b |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:101b03:*:*:*:*:*:*:*", "matchCriteriaId": "11857770-E809-483A-993F-1C827428B334", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:go-rt-ac750:revision_a:*:*:*:*:*:*:*", "matchCriteriaId": "426BE281-6336-4A4E-892B-CE8BBCA8ABF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:200b02:*:*:*:*:*:*:*", "matchCriteriaId": "E610B4D9-198B-4986-89CC-F3C75DBC3EF3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dlink:go-rt-ac750:revision_b:*:*:*:*:*:*:*", "matchCriteriaId": "5F4EF05A-EF25-4E60-8A08-9C0CDD9244EF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "D-Link GO-RT-AC750 GORTAC750_revA_v101b03 \u0026 GO-RT-AC750_revB_FWv200b02 is vulnerable to Static Default Credentials via /etc/init0.d/S80telnetd.sh." }, { "lang": "es", "value": "D-Link GO-RT-AC750 versiones GORTAC750_revA_v101b03 \u0026amp; GO-RT-AC750_revB_FWv200b02 son vulnerables a las credenciales est\u00e1ticas por defecto por medio del archivo /etc/init0.d/S80telnetd.sh." } ], "id": "CVE-2022-36524", "lastModified": "2024-11-21T07:13:13.753", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-08-15T17:15:13.823", "references": [ { "source": "cve@mitre.org", "tags": [ "Broken Link", "Product" ], "url": "http://d-link.com" }, { "source": "cve@mitre.org", "tags": [ "Broken Link", "Third Party Advisory" ], "url": "https://drive.google.com/file/d/1WNKrDUbYfSWbSve9ONILkLY6dbM8I7hh/view?usp=sharing" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link", "Product" ], "url": "http://d-link.com" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link", "Third Party Advisory" ], "url": "https://drive.google.com/file/d/1WNKrDUbYfSWbSve9ONILkLY6dbM8I7hh/view?usp=sharing" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.dlink.com/en/security-bulletin/" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-287" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
CVE-2022-36524 (GCVE-0-2022-36524)
Vulnerability from cvelistv5
Published
2022-08-15 16:33
Modified
2024-08-03 10:07
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
D-Link GO-RT-AC750 GORTAC750_revA_v101b03 & GO-RT-AC750_revB_FWv200b02 is vulnerable to Static Default Credentials via /etc/init0.d/S80telnetd.sh.
References
▼ | URL | Tags |
---|---|---|
http://d-link.com | x_refsource_MISC | |
https://www.dlink.com/en/security-bulletin/ | x_refsource_MISC | |
https://drive.google.com/file/d/1WNKrDUbYfSWbSve9ONILkLY6dbM8I7hh/view?usp=sharing | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T10:07:34.460Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://d-link.com" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://drive.google.com/file/d/1WNKrDUbYfSWbSve9ONILkLY6dbM8I7hh/view?usp=sharing" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "D-Link GO-RT-AC750 GORTAC750_revA_v101b03 \u0026 GO-RT-AC750_revB_FWv200b02 is vulnerable to Static Default Credentials via /etc/init0.d/S80telnetd.sh." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-15T16:33:54", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "http://d-link.com" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "tags": [ "x_refsource_MISC" ], "url": "https://drive.google.com/file/d/1WNKrDUbYfSWbSve9ONILkLY6dbM8I7hh/view?usp=sharing" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-36524", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "D-Link GO-RT-AC750 GORTAC750_revA_v101b03 \u0026 GO-RT-AC750_revB_FWv200b02 is vulnerable to Static Default Credentials via /etc/init0.d/S80telnetd.sh." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://d-link.com", "refsource": "MISC", "url": "http://d-link.com" }, { "name": "https://www.dlink.com/en/security-bulletin/", "refsource": "MISC", "url": "https://www.dlink.com/en/security-bulletin/" }, { "name": "https://drive.google.com/file/d/1WNKrDUbYfSWbSve9ONILkLY6dbM8I7hh/view?usp=sharing", "refsource": "MISC", "url": "https://drive.google.com/file/d/1WNKrDUbYfSWbSve9ONILkLY6dbM8I7hh/view?usp=sharing" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-36524", "datePublished": "2022-08-15T16:33:54", "dateReserved": "2022-07-25T00:00:00", "dateUpdated": "2024-08-03T10:07:34.460Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-48842 (GCVE-0-2023-48842)
Vulnerability from cvelistv5
Published
2023-12-01 00:00
Modified
2025-06-03 02:24
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at hedwig.cgi.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T21:46:28.238Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://drive.google.com/file/d/1y5om__f2SAhNmcPqDxC_SRTvJVAWwPcH/view?usp=drive_link" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-48842", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-06-03T02:23:28.359315Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-06-03T02:24:53.955Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at hedwig.cgi." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-12-01T15:16:04.709Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://drive.google.com/file/d/1y5om__f2SAhNmcPqDxC_SRTvJVAWwPcH/view?usp=drive_link" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-48842", "datePublished": "2023-12-01T00:00:00.000Z", "dateReserved": "2023-11-20T00:00:00.000Z", "dateUpdated": "2025-06-03T02:24:53.955Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-22916 (GCVE-0-2024-22916)
Vulnerability from cvelistv5
Published
2024-01-16 00:00
Modified
2024-08-29 19:53
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
In D-LINK Go-RT-AC750 v101b03, the sprintf function in the sub_40E700 function within the cgibin is susceptible to stack overflow.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T22:51:11.195Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "tags": [ "x_transferred" ], "url": "https://kee02p.github.io/2024/01/13/CVE-2024-22916/" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:dlink:go-rt-ac750_firmware:101b03:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "go-rt-ac750_firmware", "vendor": "dlink", "versions": [ { "status": "affected", "version": "101b03" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-22916", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-08-29T19:45:54.326640Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-29T19:53:52.941Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "In D-LINK Go-RT-AC750 v101b03, the sprintf function in the sub_40E700 function within the cgibin is susceptible to stack overflow." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-01-16T22:07:20.612751", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://www.dlink.com/en/security-bulletin/" }, { "url": "https://kee02p.github.io/2024/01/13/CVE-2024-22916/" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-22916", "datePublished": "2024-01-16T00:00:00", "dateReserved": "2024-01-11T00:00:00", "dateUpdated": "2024-08-29T19:53:52.941Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-37055 (GCVE-0-2022-37055)
Vulnerability from cvelistv5
Published
2022-08-28 16:05
Modified
2025-01-06 14:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
D-Link Go-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 are vulnerable to Buffer Overflow via cgibin, hnap_main,
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T10:21:32.589Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://drive.google.com/file/d/1hmIk0jQoex4QDyjIUg_6yxi-J6ROCh8S/view?usp=sharing" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "D-Link Go-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 are vulnerable to Buffer Overflow via cgibin, hnap_main," } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-06T14:51:10.345534Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://www.dlink.com/en/security-bulletin/" }, { "url": "https://drive.google.com/file/d/1hmIk0jQoex4QDyjIUg_6yxi-J6ROCh8S/view?usp=sharing" }, { "url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10308" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-37055", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "D-Link Go-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 are vulnerable to Buffer Overflow via cgibin, hnap_main," } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.dlink.com/en/security-bulletin/", "refsource": "MISC", "url": "https://www.dlink.com/en/security-bulletin/" }, { "name": "https://drive.google.com/file/d/1hmIk0jQoex4QDyjIUg_6yxi-J6ROCh8S/view?usp=sharing", "refsource": "MISC", "url": "https://drive.google.com/file/d/1hmIk0jQoex4QDyjIUg_6yxi-J6ROCh8S/view?usp=sharing" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-37055", "datePublished": "2022-08-28T16:05:21", "dateReserved": "2022-08-01T00:00:00", "dateUpdated": "2025-01-06T14:51:10.345534Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-37056 (GCVE-0-2022-37056)
Vulnerability from cvelistv5
Published
2022-08-28 16:03
Modified
2025-01-09 17:38
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Summary
D-Link GO-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 is vulnerable to Command Injection via /cgibin, hnap_main,
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T10:21:32.734Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2022-37056", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-09T15:56:42.079801Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-09T17:38:08.414Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "D-Link GO-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 is vulnerable to Command Injection via /cgibin, hnap_main," } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-06T14:32:07.758Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://www.dlink.com/en/security-bulletin/" }, { "url": "https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing" }, { "url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10308" } ], "x_generator": { "engine": "enrichogram 0.0.1" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-37056", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "D-Link GO-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 is vulnerable to Command Injection via /cgibin, hnap_main," } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.dlink.com/en/security-bulletin/", "refsource": "MISC", "url": "https://www.dlink.com/en/security-bulletin/" }, { "name": "https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing", "refsource": "MISC", "url": "https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-37056", "datePublished": "2022-08-28T16:03:48", "dateReserved": "2022-08-01T00:00:00", "dateUpdated": "2025-01-09T17:38:08.414Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-27683 (GCVE-0-2024-27683)
Vulnerability from cvelistv5
Published
2024-03-21 00:00
Modified
2024-08-14 19:07
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contains a stack-based buffer overflow via the function hnap_main. An attacker can send a POST request to trigger the vulnerablilify.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T00:34:52.538Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "tags": [ "x_transferred" ], "url": "https://drive.google.com/file/d/18RhbBnaD_kH16Y6C-7TpSSPUmYKKyU_k/view" }, { "tags": [ "x_transferred" ], "url": "https://gist.github.com/sunwithmoon/428c3871482a600382fec0a1994a518b" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:dlink:go-rt-ac750_firmware:101b03:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "go-rt-ac750_firmware", "vendor": "dlink", "versions": [ { "status": "affected", "version": "101b03" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-27683", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-08-14T19:03:53.243547Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-14T19:07:30.354Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contains a stack-based buffer overflow via the function hnap_main. An attacker can send a POST request to trigger the vulnerablilify." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-21T11:32:39.559169", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://www.dlink.com/en/security-bulletin/" }, { "url": "https://drive.google.com/file/d/18RhbBnaD_kH16Y6C-7TpSSPUmYKKyU_k/view" }, { "url": "https://gist.github.com/sunwithmoon/428c3871482a600382fec0a1994a518b" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-27683", "datePublished": "2024-03-21T00:00:00", "dateReserved": "2024-02-26T00:00:00", "dateUpdated": "2024-08-14T19:07:30.354Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-36525 (GCVE-0-2022-36525)
Vulnerability from cvelistv5
Published
2022-08-15 16:36
Modified
2024-08-03 10:07
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
D-Link Go-RT-AC750 GORTAC750_revA_v101b03 & GO-RT-AC750_revB_FWv200b02 is vulnerable to Buffer Overflow via authenticationcgi_main.
References
▼ | URL | Tags |
---|---|---|
https://www.dlink.com/en/security-bulletin/ | x_refsource_MISC | |
https://drive.google.com/file/d/1IGtqvX2y-8GIwBsK6yi04AGfIzAXXvzW/view?usp=sharing | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T10:07:34.431Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://drive.google.com/file/d/1IGtqvX2y-8GIwBsK6yi04AGfIzAXXvzW/view?usp=sharing" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "D-Link Go-RT-AC750 GORTAC750_revA_v101b03 \u0026 GO-RT-AC750_revB_FWv200b02 is vulnerable to Buffer Overflow via authenticationcgi_main." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-15T16:36:21", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "tags": [ "x_refsource_MISC" ], "url": "https://drive.google.com/file/d/1IGtqvX2y-8GIwBsK6yi04AGfIzAXXvzW/view?usp=sharing" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-36525", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "D-Link Go-RT-AC750 GORTAC750_revA_v101b03 \u0026 GO-RT-AC750_revB_FWv200b02 is vulnerable to Buffer Overflow via authenticationcgi_main." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.dlink.com/en/security-bulletin/", "refsource": "MISC", "url": "https://www.dlink.com/en/security-bulletin/" }, { "name": "https://drive.google.com/file/d/1IGtqvX2y-8GIwBsK6yi04AGfIzAXXvzW/view?usp=sharing", "refsource": "MISC", "url": "https://drive.google.com/file/d/1IGtqvX2y-8GIwBsK6yi04AGfIzAXXvzW/view?usp=sharing" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-36525", "datePublished": "2022-08-15T16:36:21", "dateReserved": "2022-07-25T00:00:00", "dateUpdated": "2024-08-03T10:07:34.431Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-34800 (GCVE-0-2023-34800)
Vulnerability from cvelistv5
Published
2023-06-15 00:00
Modified
2024-12-16 19:45
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at genacgi_main.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T16:17:04.339Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "tags": [ "x_transferred" ], "url": "https://github.com/Tyaoo/IoT-Vuls/blob/main/dlink/Go-RT-AC750/vul.md" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-34800", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-12-16T19:42:04.175887Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-16T19:45:16.331Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at genacgi_main." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-06-15T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://www.dlink.com/en/security-bulletin/" }, { "url": "https://github.com/Tyaoo/IoT-Vuls/blob/main/dlink/Go-RT-AC750/vul.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-34800", "datePublished": "2023-06-15T00:00:00", "dateReserved": "2023-06-07T00:00:00", "dateUpdated": "2024-12-16T19:45:16.331Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-27684 (GCVE-0-2024-27684)
Vulnerability from cvelistv5
Published
2024-03-04 00:00
Modified
2024-08-16 15:53
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A Cross-site scripting (XSS) vulnerability in dlapn.cgi, dldongle.cgi, dlcfg.cgi, fwup.cgi and seama.cgi in D-Link GORTAC750_A1_FW_v101b03 allows remote attackers to inject arbitrary web script or HTML via the url parameter.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T00:34:52.524Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "tags": [ "x_transferred" ], "url": "https://drive.google.com/file/d/1qu4iBQGeAwolTXjVOTXsAAusSHo2ie-Y/view" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:dlink:gortac750_a1_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "gortac750_a1_firmware", "vendor": "dlink", "versions": [ { "status": "affected", "version": "101b03" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-27684", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-03-04T16:35:29.279350Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-16T15:53:22.513Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A Cross-site scripting (XSS) vulnerability in dlapn.cgi, dldongle.cgi, dlcfg.cgi, fwup.cgi and seama.cgi in D-Link GORTAC750_A1_FW_v101b03 allows remote attackers to inject arbitrary web script or HTML via the url parameter." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-04T13:47:37.638773", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://www.dlink.com/en/security-bulletin/" }, { "url": "https://drive.google.com/file/d/1qu4iBQGeAwolTXjVOTXsAAusSHo2ie-Y/view" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-27684", "datePublished": "2024-03-04T00:00:00", "dateReserved": "2024-02-26T00:00:00", "dateUpdated": "2024-08-16T15:53:22.513Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-22853 (GCVE-0-2024-22853)
Vulnerability from cvelistv5
Published
2024-02-06 00:00
Modified
2025-06-20 20:13
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
D-LINK Go-RT-AC750 GORTAC750_A1_FW_v101b03 has a hardcoded password for the Alphanetworks account, which allows remote attackers to obtain root access via a telnet session.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T22:51:11.111Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "tags": [ "x_transferred" ], "url": "https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/2/2.md" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-22853", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-02-06T15:37:40.936496Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-798", "description": "CWE-798 Use of Hard-coded Credentials", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-06-20T20:13:39.786Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "D-LINK Go-RT-AC750 GORTAC750_A1_FW_v101b03 has a hardcoded password for the Alphanetworks account, which allows remote attackers to obtain root access via a telnet session." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-02-06T01:18:48.256Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://www.dlink.com/en/security-bulletin/" }, { "url": "https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/2/2.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-22853", "datePublished": "2024-02-06T00:00:00.000Z", "dateReserved": "2024-01-11T00:00:00.000Z", "dateUpdated": "2025-06-20T20:13:39.786Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-36523 (GCVE-0-2022-36523)
Vulnerability from cvelistv5
Published
2022-08-15 16:30
Modified
2024-08-03 10:07
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
D-Link Go-RT-AC750 GORTAC750_revA_v101b03 & GO-RT-AC750_revB_FWv200b02 is vulnerable to command injection via /htdocs/upnpinc/gena.php.
References
▼ | URL | Tags |
---|---|---|
https://www.dlink.com/en/security-bulletin/ | x_refsource_MISC | |
https://drive.google.com/file/d/13D6K0UxNNzbLU4YRPfJc7MAk6iKFICdr/view?usp=sharing | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T10:07:34.262Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://drive.google.com/file/d/13D6K0UxNNzbLU4YRPfJc7MAk6iKFICdr/view?usp=sharing" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "D-Link Go-RT-AC750 GORTAC750_revA_v101b03 \u0026 GO-RT-AC750_revB_FWv200b02 is vulnerable to command injection via /htdocs/upnpinc/gena.php." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-15T16:30:52", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "tags": [ "x_refsource_MISC" ], "url": "https://drive.google.com/file/d/13D6K0UxNNzbLU4YRPfJc7MAk6iKFICdr/view?usp=sharing" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-36523", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "D-Link Go-RT-AC750 GORTAC750_revA_v101b03 \u0026 GO-RT-AC750_revB_FWv200b02 is vulnerable to command injection via /htdocs/upnpinc/gena.php." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.dlink.com/en/security-bulletin/", "refsource": "MISC", "url": "https://www.dlink.com/en/security-bulletin/" }, { "name": "https://drive.google.com/file/d/13D6K0UxNNzbLU4YRPfJc7MAk6iKFICdr/view?usp=sharing", "refsource": "MISC", "url": "https://drive.google.com/file/d/13D6K0UxNNzbLU4YRPfJc7MAk6iKFICdr/view?usp=sharing" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-36523", "datePublished": "2022-08-15T16:30:52", "dateReserved": "2022-07-25T00:00:00", "dateUpdated": "2024-08-03T10:07:34.262Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-37057 (GCVE-0-2022-37057)
Vulnerability from cvelistv5
Published
2022-08-28 16:00
Modified
2025-01-06 14:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
D-Link Go-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 are vulnerable to Command Injection via cgibin, ssdpcgi_main.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T10:21:32.799Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://drive.google.com/file/d/1_UUpraFTxxB97ujrgVLQZXQ8Q8M58BAF/view?usp=sharing" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "D-Link Go-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 are vulnerable to Command Injection via cgibin, ssdpcgi_main." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-06T14:51:42.583347Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://www.dlink.com/en/security-bulletin/" }, { "url": "https://drive.google.com/file/d/1_UUpraFTxxB97ujrgVLQZXQ8Q8M58BAF/view?usp=sharing" }, { "url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10308" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-37057", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "D-Link Go-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 are vulnerable to Command Injection via cgibin, ssdpcgi_main." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.dlink.com/en/security-bulletin/", "refsource": "MISC", "url": "https://www.dlink.com/en/security-bulletin/" }, { "name": "https://drive.google.com/file/d/1_UUpraFTxxB97ujrgVLQZXQ8Q8M58BAF/view?usp=sharing", "refsource": "MISC", "url": "https://drive.google.com/file/d/1_UUpraFTxxB97ujrgVLQZXQ8Q8M58BAF/view?usp=sharing" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-37057", "datePublished": "2022-08-28T16:00:15", "dateReserved": "2022-08-01T00:00:00", "dateUpdated": "2025-01-06T14:51:42.583347Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-36526 (GCVE-0-2022-36526)
Vulnerability from cvelistv5
Published
2022-08-15 16:39
Modified
2024-08-03 10:07
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
D-Link GO-RT-AC750 GORTAC750_revA_v101b03 & GO-RT-AC750_revB_FWv200b02 is vulnerable to Authentication Bypass via function phpcgi_main in cgibin.
References
▼ | URL | Tags |
---|---|---|
http://d-link.com | x_refsource_MISC | |
https://www.dlink.com/en/security-bulletin/ | x_refsource_MISC | |
https://drive.google.com/file/d/1ji5Ph6c-qgp0lBvbY8BZJjeqbju3VeK8/view?usp=sharing | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T10:07:34.428Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://d-link.com" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://drive.google.com/file/d/1ji5Ph6c-qgp0lBvbY8BZJjeqbju3VeK8/view?usp=sharing" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "D-Link GO-RT-AC750 GORTAC750_revA_v101b03 \u0026 GO-RT-AC750_revB_FWv200b02 is vulnerable to Authentication Bypass via function phpcgi_main in cgibin." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-15T16:39:54", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "http://d-link.com" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "tags": [ "x_refsource_MISC" ], "url": "https://drive.google.com/file/d/1ji5Ph6c-qgp0lBvbY8BZJjeqbju3VeK8/view?usp=sharing" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-36526", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "D-Link GO-RT-AC750 GORTAC750_revA_v101b03 \u0026 GO-RT-AC750_revB_FWv200b02 is vulnerable to Authentication Bypass via function phpcgi_main in cgibin." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://d-link.com", "refsource": "MISC", "url": "http://d-link.com" }, { "name": "https://www.dlink.com/en/security-bulletin/", "refsource": "MISC", "url": "https://www.dlink.com/en/security-bulletin/" }, { "name": "https://drive.google.com/file/d/1ji5Ph6c-qgp0lBvbY8BZJjeqbju3VeK8/view?usp=sharing", "refsource": "MISC", "url": "https://drive.google.com/file/d/1ji5Ph6c-qgp0lBvbY8BZJjeqbju3VeK8/view?usp=sharing" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-36526", "datePublished": "2022-08-15T16:39:54", "dateReserved": "2022-07-25T00:00:00", "dateUpdated": "2024-08-03T10:07:34.428Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-26822 (GCVE-0-2023-26822)
Vulnerability from cvelistv5
Published
2023-04-01 00:00
Modified
2025-02-11 17:12
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at soapcgi.main.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:53:54.522Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "tags": [ "x_transferred" ], "url": "https://github.com/yzskyt/Vuln/blob/main/Go-RT-AC750/Go-RT-AC750.md" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-26822", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-11T17:12:22.889168Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-77", "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-11T17:12:28.548Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at soapcgi.main." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-01T00:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://www.dlink.com/en/security-bulletin/" }, { "url": "https://github.com/yzskyt/Vuln/blob/main/Go-RT-AC750/Go-RT-AC750.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-26822", "datePublished": "2023-04-01T00:00:00.000Z", "dateReserved": "2023-02-27T00:00:00.000Z", "dateUpdated": "2025-02-11T17:12:28.548Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-22852 (GCVE-0-2024-22852)
Vulnerability from cvelistv5
Published
2024-02-06 00:00
Modified
2025-05-15 19:45
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contains a stack-based buffer overflow via the function genacgi_main. This vulnerability allows attackers to enable telnet service via a specially crafted payload.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T22:51:11.136Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "tags": [ "x_transferred" ], "url": "https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/1/1.md" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-22852", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-05-08T15:58:45.552998Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-05-15T19:45:54.686Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contains a stack-based buffer overflow via the function genacgi_main. This vulnerability allows attackers to enable telnet service via a specially crafted payload." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-02-06T01:18:42.565Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://www.dlink.com/en/security-bulletin/" }, { "url": "https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/1/1.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-22852", "datePublished": "2024-02-06T00:00:00.000Z", "dateReserved": "2024-01-11T00:00:00.000Z", "dateUpdated": "2025-05-15T19:45:54.686Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }