2 vulnerabilities found for fireflow by algosec

CVE-2023-46595 (GCVE-0-2023-46595)
Vulnerability from nvd
Published
2023-11-02 07:47
Modified
2025-11-12 08:38
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Summary
Net-NTLM leak via HTML injection in FireFlow VisualFlow workflow editor allows an attacker to obtain victim’s domain credentials and Net-NTLM hash which can lead to relay domain attacks. Fixed in A32.20 (b570 or above), A32.50 (b390 or above)
Impacted products
Vendor Product Version
Algosec Algosec FireFlow Version: A32.20, A32.50
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T20:45:42.290Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cwe.mitre.org/data/definitions/79.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "64 bit",
            "Linux"
          ],
          "product": "Algosec FireFlow",
          "vendor": "Algosec",
          "versions": [
            {
              "status": "affected",
              "version": "A32.20, A32.50"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Micha\u0142 Bogdanowicz from Nordea Bank ABP (https://www.linkedin.com/in/micha%C5%82-bogdanowicz-603267a8/)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Net-NTLM leak via HTML injection in FireFlow VisualFlow workflow editor\u0026nbsp;allows an attacker\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eto obtain victim\u2019s domain credentials and Net-NTLM hash which can lead\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;to relay domain attacks. Fixed in\u0026nbsp;A32.20 (b570 or above),  A32.50 (b390 or above)\n\n\u003c/span\u003e\u003c/span\u003e"
            }
          ],
          "value": "Net-NTLM leak via HTML injection in FireFlow VisualFlow workflow editor\u00a0allows an attacker\u00a0to obtain victim\u2019s domain credentials and Net-NTLM hash which can lead\u00a0to relay domain attacks. Fixed in\u00a0A32.20 (b570 or above),  A32.50 (b390 or above)"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-21",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-21 Exploitation of Trusted Credentials"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-12T08:38:33.676Z",
        "orgId": "ca5f073f-8266-4d43-b3e3-6eb0bb18a738",
        "shortName": "AlgoSec"
      },
      "references": [
        {
          "url": "https://cwe.mitre.org/data/definitions/79.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade ASMS suite to\u0026nbsp;A32.20 (b570 or above),\u0026nbsp; A32.50 (b390 or above)\u003cbr\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://portal.algosec.com/en/downloads/hotfix_releases\"\u003ehttps://portal.algosec.com/en/downloads/hotfix_releases\u003c/a\u003e\u003cbr\u003e"
            }
          ],
          "value": "Upgrade ASMS suite to\u00a0A32.20 (b570 or above),\u00a0 A32.50 (b390 or above)\n https://portal.algosec.com/en/downloads/hotfix_releases https://portal.algosec.com/en/downloads/hotfix_releases"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Net-NTLM leak via HTML injection in FireFlow VisualFlow workflow editor",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ca5f073f-8266-4d43-b3e3-6eb0bb18a738",
    "assignerShortName": "AlgoSec",
    "cveId": "CVE-2023-46595",
    "datePublished": "2023-11-02T07:47:50.794Z",
    "dateReserved": "2023-10-23T10:00:57.893Z",
    "dateUpdated": "2025-11-12T08:38:33.676Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2023-46595 (GCVE-0-2023-46595)
Vulnerability from cvelistv5
Published
2023-11-02 07:47
Modified
2025-11-12 08:38
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Summary
Net-NTLM leak via HTML injection in FireFlow VisualFlow workflow editor allows an attacker to obtain victim’s domain credentials and Net-NTLM hash which can lead to relay domain attacks. Fixed in A32.20 (b570 or above), A32.50 (b390 or above)
Impacted products
Vendor Product Version
Algosec Algosec FireFlow Version: A32.20, A32.50
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T20:45:42.290Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cwe.mitre.org/data/definitions/79.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "64 bit",
            "Linux"
          ],
          "product": "Algosec FireFlow",
          "vendor": "Algosec",
          "versions": [
            {
              "status": "affected",
              "version": "A32.20, A32.50"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Micha\u0142 Bogdanowicz from Nordea Bank ABP (https://www.linkedin.com/in/micha%C5%82-bogdanowicz-603267a8/)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Net-NTLM leak via HTML injection in FireFlow VisualFlow workflow editor\u0026nbsp;allows an attacker\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eto obtain victim\u2019s domain credentials and Net-NTLM hash which can lead\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;to relay domain attacks. Fixed in\u0026nbsp;A32.20 (b570 or above),  A32.50 (b390 or above)\n\n\u003c/span\u003e\u003c/span\u003e"
            }
          ],
          "value": "Net-NTLM leak via HTML injection in FireFlow VisualFlow workflow editor\u00a0allows an attacker\u00a0to obtain victim\u2019s domain credentials and Net-NTLM hash which can lead\u00a0to relay domain attacks. Fixed in\u00a0A32.20 (b570 or above),  A32.50 (b390 or above)"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-21",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-21 Exploitation of Trusted Credentials"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-12T08:38:33.676Z",
        "orgId": "ca5f073f-8266-4d43-b3e3-6eb0bb18a738",
        "shortName": "AlgoSec"
      },
      "references": [
        {
          "url": "https://cwe.mitre.org/data/definitions/79.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade ASMS suite to\u0026nbsp;A32.20 (b570 or above),\u0026nbsp; A32.50 (b390 or above)\u003cbr\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://portal.algosec.com/en/downloads/hotfix_releases\"\u003ehttps://portal.algosec.com/en/downloads/hotfix_releases\u003c/a\u003e\u003cbr\u003e"
            }
          ],
          "value": "Upgrade ASMS suite to\u00a0A32.20 (b570 or above),\u00a0 A32.50 (b390 or above)\n https://portal.algosec.com/en/downloads/hotfix_releases https://portal.algosec.com/en/downloads/hotfix_releases"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Net-NTLM leak via HTML injection in FireFlow VisualFlow workflow editor",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ca5f073f-8266-4d43-b3e3-6eb0bb18a738",
    "assignerShortName": "AlgoSec",
    "cveId": "CVE-2023-46595",
    "datePublished": "2023-11-02T07:47:50.794Z",
    "dateReserved": "2023-10-23T10:00:57.893Z",
    "dateUpdated": "2025-11-12T08:38:33.676Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}