Refine your search
1 vulnerability found for carlcare by transsion
CVE-2024-7697 (GCVE-0-2024-7697)
Vulnerability from nvd
Published
2024-08-12 08:12
Modified
2025-09-05 06:24
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-359 - Exposure of Private Personal Information to an Unauthorized Actor
Summary
Logical vulnerability in the mobile application (com.transsion.carlcare) may lead to user information leakage risks.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| TECNO | com.transsion.carlcare |
Version: 5.9.5 |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:tecno:com.transsion.carlcare:5.9.5:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "com.transsion.carlcare",
"vendor": "tecno",
"versions": [
{
"status": "affected",
"version": "5.9.5"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-7697",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-12T14:08:51.191706Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-12T14:26:59.532Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "com.transsion.carlcare",
"vendor": "TECNO",
"versions": [
{
"status": "affected",
"version": "5.9.5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eLogical vulnerability in the mobile application (com.transsion.carlcare) may lead to user information leakage risks.\u003c/span\u003e"
}
],
"value": "Logical vulnerability in the mobile application (com.transsion.carlcare) may lead to user information leakage risks."
}
],
"impacts": [
{
"capecId": "CAPEC-131",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-131 Resource Leak Exposure"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-359",
"description": "CWE-359 Exposure of Private Personal Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-05T06:24:38.831Z",
"orgId": "907edf6c-bf03-423e-ab1a-8da27e1aa1ea",
"shortName": "TECNOMobile"
},
"references": [
{
"url": "https://security.tecno.com/SRC/blogdetail/294?lang=en_US"
},
{
"url": "https://security.tecno.com/SRC/securityUpdates?type=SA"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Logical vulnerability in com.transsion.carlcare",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "907edf6c-bf03-423e-ab1a-8da27e1aa1ea",
"assignerShortName": "TECNOMobile",
"cveId": "CVE-2024-7697",
"datePublished": "2024-08-12T08:12:27.536Z",
"dateReserved": "2024-08-12T07:51:32.503Z",
"dateUpdated": "2025-09-05T06:24:38.831Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}