Vulnerabilites related to Dell - Unisphere for PowerMax
var-202112-2521
Vulnerability from variot

Unisphere for PowerMax versions prior to 9.2.2.2 contains a privilege escalation vulnerability. An adjacent malicious user could potentially exploit this vulnerability to escalate their privileges and access functionalities they do not have access to. CVE-2022-31233 addresses the partial fix in CVE-2021-36338. plural Dell EMC Products have not undergone verification and integrity checks Cookie There is a vulnerability related to dependency on.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. DELL Dell EMC Unisphere for PowerMax is a set of graphical management tools for PowerMax storage arrays developed by Dell (DELL). Dell EMC Unisphere for PowerMax has a security vulnerability that could be exploited by an attacker to elevate privileges

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2521",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "unisphere for powermax",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.3.4"
      },
      {
        "model": "unisphere for powermax virtual appliance",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.3.4"
      },
      {
        "model": "powermax os",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "dell",
        "version": "5978"
      },
      {
        "model": "unisphere 360",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.1.0.29"
      },
      {
        "model": "solutions enabler",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.3.0"
      },
      {
        "model": "unisphere 360",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.0.0"
      },
      {
        "model": "vasa",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.1.0.723"
      },
      {
        "model": "vasa",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.3.0"
      },
      {
        "model": "unisphere 360",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.3.3"
      },
      {
        "model": "solutions enabler",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.0.0"
      },
      {
        "model": "solutions enabler virtual appliance",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.3.0"
      },
      {
        "model": "vasa",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.0.0"
      },
      {
        "model": "solutions enabler virtual appliance",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.0.0"
      },
      {
        "model": "unisphere for powermax virtual appliance",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.0.0"
      },
      {
        "model": "unisphere for powermax virtual appliance",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.1.0.31"
      },
      {
        "model": "unisphere for powermax",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.1.0.31"
      },
      {
        "model": "solutions enabler",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.1.0.18"
      },
      {
        "model": "solutions enabler virtual appliance",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.1.0.18"
      },
      {
        "model": "unisphere for powermax",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.0.0"
      },
      {
        "model": "dell unisphere for powermax virtual appliance",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      },
      {
        "model": "dell solutions enabler",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      },
      {
        "model": "dell unisphere for powermax",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      },
      {
        "model": "dell powermax os",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      },
      {
        "model": "solutions enabler virtual appliance",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      },
      {
        "model": "unisphere 360",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      },
      {
        "model": "vasa",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018029"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-36338"
      }
    ]
  },
  "cve": "CVE-2021-36338",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "SINGLE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.2,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 5.1,
            "id": "CVE-2021-36338",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "SINGLE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.2,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 5.1,
            "id": "VHN-398222",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:A/AC:L/AU:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.0,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.1,
            "id": "CVE-2021-36338",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "security_alert@emc.com",
            "availabilityImpact": "NONE",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 2.1,
            "id": "CVE-2021-36338",
            "impactScore": 4.2,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Adjacent Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.0,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2021-36338",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2021-36338",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "security_alert@emc.com",
            "id": "CVE-2021-36338",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2021-36338",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202112-2209",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-398222",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-398222"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018029"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2209"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-36338"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-36338"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Unisphere for PowerMax versions prior to 9.2.2.2 contains a privilege escalation vulnerability. An adjacent malicious user could potentially exploit this vulnerability to escalate their privileges and access functionalities they do not have access to. CVE-2022-31233 addresses the partial fix in CVE-2021-36338. plural Dell EMC Products have not undergone verification and integrity checks Cookie There is a vulnerability related to dependency on.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. DELL Dell EMC Unisphere for PowerMax is a set of graphical management tools for PowerMax storage arrays developed by Dell (DELL). Dell EMC Unisphere for PowerMax has a security vulnerability that could be exploited by an attacker to elevate privileges",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-36338"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018029"
      },
      {
        "db": "VULHUB",
        "id": "VHN-398222"
      }
    ],
    "trust": 1.71
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-36338",
        "trust": 3.3
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018029",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2209",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-06904",
        "trust": 0.1
      },
      {
        "db": "VULHUB",
        "id": "VHN-398222",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-398222"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018029"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2209"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-36338"
      }
    ]
  },
  "id": "VAR-202112-2521",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-398222"
      }
    ],
    "trust": 0.628721285
  },
  "last_update_date": "2024-08-14T14:50:01.417000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "DSA-2021-226",
        "trust": 0.8,
        "url": "https://www.dell.com/support/kbdoc/ja-jp/000194640/dsa-2021-226-dell-emc-unisphere-for-powermax-dell-emc-unisphere-for-powermax-virtual-appliance-dell-emc-solutions-enabler-virtual-appliance-dell-emc-unisphere-360-dell-emc-vasa-and-dell-emc-powermax-embed"
      },
      {
        "title": "Dell EMC Unisphere for PowerMax Security vulnerabilities",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=175675"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018029"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2209"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-565",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-602",
        "trust": 1.0
      },
      {
        "problemtype": "No validation and integrity checks  Cookie Dependence on (CWE-565) [NVD evaluation ]",
        "trust": 0.8
      },
      {
        "problemtype": "CWE-669",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-398222"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018029"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-36338"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.7,
        "url": "https://www.dell.com/support/kbdoc/000194640"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-36338"
      },
      {
        "trust": 0.6,
        "url": "https://vigilance.fr/vulnerability/dell-emc-unisphere-for-powermax-privilege-escalation-37122"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-398222"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018029"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2209"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-36338"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-398222"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018029"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2209"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-36338"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-01-21T00:00:00",
        "db": "VULHUB",
        "id": "VHN-398222"
      },
      {
        "date": "2023-03-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-018029"
      },
      {
        "date": "2021-12-22T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202112-2209"
      },
      {
        "date": "2022-01-21T21:15:08.487000",
        "db": "NVD",
        "id": "CVE-2021-36338"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-12-09T00:00:00",
        "db": "VULHUB",
        "id": "VHN-398222"
      },
      {
        "date": "2023-03-20T03:49:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-018029"
      },
      {
        "date": "2022-12-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202112-2209"
      },
      {
        "date": "2022-12-09T16:26:50.893000",
        "db": "NVD",
        "id": "CVE-2021-36338"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote or local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2209"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0Dell\u00a0EMC\u00a0 Lack of verification and integrity checks on products \u00a0Cookie\u00a0 Dependency vulnerabilities",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018029"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2209"
      }
    ],
    "trust": 0.6
  }
}

var-202104-0672
Vulnerability from variot

Dell Unisphere for PowerMax versions prior to 9.2.1.6 contain an Authorization Bypass Vulnerability. A local authenticated malicious user with monitor role may exploit this vulnerability to perform unauthorized actions. Dell Unisphere for PowerMax Exists in a vulnerability related to incorrect resource movement between regions.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. DELL Dell EMC Unisphere for PowerMax is a set of graphical management tools for PowerMax storage arrays developed by Dell (DELL). A security vulnerability exists in PowerMax that could allow an attacker to bypass restrictions through Dell Unisphere's PowerMax monitoring role to escalate privileges

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202104-0672",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "solutions enabler",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.1.6"
      },
      {
        "model": "unisphere for powermax virtual appliance",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.1.0"
      },
      {
        "model": "solutions enabler virtual appliance",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.1.1"
      },
      {
        "model": "solutions enabler",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.0"
      },
      {
        "model": "powermax os",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "dell",
        "version": "5978"
      },
      {
        "model": "solutions enabler virtual appliance",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.0"
      },
      {
        "model": "unisphere for powermax virtual appliance",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.1.6"
      },
      {
        "model": "unisphere for powermax virtual appliance",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.1.0.26"
      },
      {
        "model": "unisphere for powermax",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.1.0"
      },
      {
        "model": "unisphere for powermax",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.1.0.26"
      },
      {
        "model": "solutions enabler",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.1.0.15"
      },
      {
        "model": "unisphere for powermax",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.1.6"
      },
      {
        "model": "solutions enabler virtual appliance",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.1.0.15"
      },
      {
        "model": "dell unisphere for powermax",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      },
      {
        "model": "dell unisphere for powermax virtual appliance",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      },
      {
        "model": "dell solutions enabler",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      },
      {
        "model": "dell solutions enabler virtual appliance",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      },
      {
        "model": "dell powermax os",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-006445"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-21531"
      }
    ]
  },
  "cve": "CVE-2021-21531",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.6,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 3.9,
            "id": "CVE-2021-21531",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.9,
            "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.6,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 3.9,
            "id": "VHN-379935",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:L/AC:L/AU:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2021-21531",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "security_alert@emc.com",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "id": "CVE-2021-21531",
            "impactScore": 5.2,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2021-21531",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2021-21531",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "security_alert@emc.com",
            "id": "CVE-2021-21531",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2021-21531",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202103-1551",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-379935",
            "trust": 0.1,
            "value": "MEDIUM"
          },
          {
            "author": "VULMON",
            "id": "CVE-2021-21531",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-379935"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-21531"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-006445"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202103-1551"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-21531"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-21531"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Dell Unisphere for PowerMax versions prior to 9.2.1.6 contain an Authorization Bypass Vulnerability. A local authenticated malicious user with monitor role may exploit this vulnerability to perform unauthorized actions. Dell Unisphere for PowerMax Exists in a vulnerability related to incorrect resource movement between regions.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. DELL Dell EMC Unisphere for PowerMax is a set of graphical management tools for PowerMax storage arrays developed by Dell (DELL). A security vulnerability exists in PowerMax that could allow an attacker to bypass restrictions through Dell Unisphere\u0027s PowerMax monitoring role to escalate privileges",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-21531"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-006445"
      },
      {
        "db": "VULHUB",
        "id": "VHN-379935"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-21531"
      }
    ],
    "trust": 1.8
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-21531",
        "trust": 3.4
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-006445",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202103-1551",
        "trust": 0.7
      },
      {
        "db": "VULHUB",
        "id": "VHN-379935",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-21531",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-379935"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-21531"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-006445"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202103-1551"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-21531"
      }
    ]
  },
  "id": "VAR-202104-0672",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-379935"
      }
    ],
    "trust": 0.58051947
  },
  "last_update_date": "2024-08-14T15:27:47.088000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "DSA-2021-063",
        "trust": 0.8,
        "url": "https://www.dell.com/support/kbdoc/000184565"
      },
      {
        "title": "PowerMax Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=145434"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-006445"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202103-1551"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-669",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-602",
        "trust": 1.0
      },
      {
        "problemtype": "Incorrect resource movement between regions (CWE-669) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-379935"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-006445"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-21531"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://www.dell.com/support/kbdoc/000184565"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-21531"
      },
      {
        "trust": 0.6,
        "url": "https://vigilance.fr/vulnerability/dell-unisphere-for-powermax-privilege-escalation-via-monitor-role-34946"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/669.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-379935"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-21531"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-006445"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202103-1551"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-21531"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-379935"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-21531"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-006445"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202103-1551"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-21531"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-04-30T00:00:00",
        "db": "VULHUB",
        "id": "VHN-379935"
      },
      {
        "date": "2021-04-30T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-21531"
      },
      {
        "date": "2022-01-06T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-006445"
      },
      {
        "date": "2021-03-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202103-1551"
      },
      {
        "date": "2021-04-30T21:15:08.673000",
        "db": "NVD",
        "id": "CVE-2021-21531"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-05-10T00:00:00",
        "db": "VULHUB",
        "id": "VHN-379935"
      },
      {
        "date": "2021-05-10T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-21531"
      },
      {
        "date": "2022-01-06T08:32:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-006445"
      },
      {
        "date": "2021-05-11T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202103-1551"
      },
      {
        "date": "2021-05-10T14:07:37.923000",
        "db": "NVD",
        "id": "CVE-2021-21531"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202103-1551"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Dell\u00a0Unisphere\u00a0for\u00a0PowerMax\u00a0 Vulnerability regarding incorrect resource movement between regions in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-006445"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202103-1551"
      }
    ],
    "trust": 0.6
  }
}

var-202112-2522
Vulnerability from variot

The Dell EMC Virtual Appliances before 9.2.2.2 contain undocumented user accounts. A local malicious user may potentially exploit this vulnerability to get privileged access to the virtual appliance. plural Dell EMC There are unspecified vulnerabilities in the product.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. DELL Dell EMC Unisphere for PowerMax is a set of graphical management tools for PowerMax storage arrays developed by Dell (DELL). There is a security vulnerability in Dell EMC Unisphere for PowerMax, which stems from the software's lack of effective restriction and filtering of user rights

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2522",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "unisphere for powermax",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.3.4"
      },
      {
        "model": "unisphere for powermax virtual appliance",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.3.4"
      },
      {
        "model": "powermax os",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "dell",
        "version": "5978"
      },
      {
        "model": "unisphere 360",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.1.0.29"
      },
      {
        "model": "solutions enabler",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.3.0"
      },
      {
        "model": "unisphere 360",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.0.0"
      },
      {
        "model": "vasa",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.1.0.723"
      },
      {
        "model": "vasa",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.3.0"
      },
      {
        "model": "unisphere 360",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.3.3"
      },
      {
        "model": "solutions enabler",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.0.0"
      },
      {
        "model": "solutions enabler virtual appliance",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.3.0"
      },
      {
        "model": "vasa",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.0.0"
      },
      {
        "model": "solutions enabler virtual appliance",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.0.0"
      },
      {
        "model": "unisphere for powermax virtual appliance",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.0.0"
      },
      {
        "model": "unisphere for powermax virtual appliance",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.1.0.31"
      },
      {
        "model": "unisphere for powermax",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.1.0.31"
      },
      {
        "model": "solutions enabler",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.1.0.18"
      },
      {
        "model": "solutions enabler virtual appliance",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.1.0.18"
      },
      {
        "model": "unisphere for powermax",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.0.0"
      },
      {
        "model": "dell unisphere for powermax virtual appliance",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      },
      {
        "model": "dell solutions enabler",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      },
      {
        "model": "dell unisphere for powermax",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      },
      {
        "model": "dell powermax os",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      },
      {
        "model": "solutions enabler virtual appliance",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      },
      {
        "model": "unisphere 360",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      },
      {
        "model": "vasa",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018028"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-36339"
      }
    ]
  },
  "cve": "CVE-2021-36339",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.6,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 3.9,
            "id": "CVE-2021-36339",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.9,
            "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.6,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 3.9,
            "id": "VHN-398223",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:L/AC:L/AU:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2021-36339",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "OTHER",
            "availabilityImpact": "High",
            "baseScore": 7.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2021-018028",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2021-36339",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "security_alert@emc.com",
            "id": "CVE-2021-36339",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2021-36339",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202112-2204",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-398223",
            "trust": 0.1,
            "value": "MEDIUM"
          },
          {
            "author": "VULMON",
            "id": "CVE-2021-36339",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-398223"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-36339"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018028"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2204"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-36339"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-36339"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The Dell EMC Virtual Appliances before 9.2.2.2 contain undocumented user accounts. A local malicious user may potentially exploit this vulnerability to get privileged access to the virtual appliance. plural Dell EMC There are unspecified vulnerabilities in the product.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. DELL Dell EMC Unisphere for PowerMax is a set of graphical management tools for PowerMax storage arrays developed by Dell (DELL). There is a security vulnerability in Dell EMC Unisphere for PowerMax, which stems from the software\u0027s lack of effective restriction and filtering of user rights",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-36339"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018028"
      },
      {
        "db": "VULHUB",
        "id": "VHN-398223"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-36339"
      }
    ],
    "trust": 1.8
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-36339",
        "trust": 3.4
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018028",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2204",
        "trust": 0.6
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-06903",
        "trust": 0.1
      },
      {
        "db": "VULHUB",
        "id": "VHN-398223",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-36339",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-398223"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-36339"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018028"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2204"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-36339"
      }
    ]
  },
  "id": "VAR-202112-2522",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-398223"
      }
    ],
    "trust": 0.628721285
  },
  "last_update_date": "2024-08-14T13:43:05.760000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "DSA-2021-226",
        "trust": 0.8,
        "url": "https://www.dell.com/support/kbdoc/ja-jp/000194640/dsa-2021-226-dell-emc-unisphere-for-powermax-dell-emc-unisphere-for-powermax-virtual-appliance-dell-emc-solutions-enabler-virtual-appliance-dell-emc-unisphere-360-dell-emc-vasa-and-dell-emc-powermax-embed"
      },
      {
        "title": "",
        "trust": 0.1,
        "url": "https://github.com/Live-Hack-CVE/CVE-2021-36339 "
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2021-36339"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018028"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-250",
        "trust": 1.0
      },
      {
        "problemtype": "NVD-CWE-Other",
        "trust": 1.0
      },
      {
        "problemtype": "others (CWE-Other) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018028"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-36339"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://www.dell.com/support/kbdoc/000194640"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-36339"
      },
      {
        "trust": 0.6,
        "url": "https://vigilance.fr/vulnerability/dell-emc-virtual-appliances-user-access-via-undocumented-user-accounts-37123"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/.html"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/live-hack-cve/cve-2021-36339"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-398223"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-36339"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018028"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2204"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-36339"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-398223"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-36339"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018028"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2204"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-36339"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-01-21T00:00:00",
        "db": "VULHUB",
        "id": "VHN-398223"
      },
      {
        "date": "2022-01-21T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-36339"
      },
      {
        "date": "2023-03-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-018028"
      },
      {
        "date": "2021-12-22T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202112-2204"
      },
      {
        "date": "2022-01-21T21:15:08.563000",
        "db": "NVD",
        "id": "CVE-2021-36339"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-10-27T00:00:00",
        "db": "VULHUB",
        "id": "VHN-398223"
      },
      {
        "date": "2022-10-27T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-36339"
      },
      {
        "date": "2023-03-20T03:46:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-018028"
      },
      {
        "date": "2022-10-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202112-2204"
      },
      {
        "date": "2022-10-27T11:44:58.323000",
        "db": "NVD",
        "id": "CVE-2021-36339"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2204"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0Dell\u00a0EMC\u00a0 Product vulnerabilities",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018028"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2204"
      }
    ],
    "trust": 0.6
  }
}

var-202206-2277
Vulnerability from variot

Unisphere for PowerMax versions before 9.2.3.15 contain a privilege escalation vulnerability. An adjacent malicious user may potentially exploit this vulnerability to escalate their privileges and access functionalities they do not have access to. eVASA Provider Virtual Appliance , Dell Solutions Enabler , Solutions Enabler Virtual Appliance Multiple Dell products are vulnerable to incorrect movement of resources between regions.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Dell EMC Unisphere for PowerMax is a set of graphical management tools for PowerMax storage arrays developed by Dell. Dell EMC Unisphere for PowerMax has a security vulnerability. An attacker exploited this vulnerability to bypass the restrictions of Dell EMC Unisphere for PowerMax to elevate his privileges

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202206-2277",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "solutions enabler",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.3.4"
      },
      {
        "model": "powermax os",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "dell",
        "version": "5978"
      },
      {
        "model": "vasa",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.3.15"
      },
      {
        "model": "unisphere for powermax virtual appliance",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.3.15"
      },
      {
        "model": "evasa provider virtual appliance",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.3.7"
      },
      {
        "model": "unisphere 360",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.3.6"
      },
      {
        "model": "solutions enabler virtual appliance",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.3.4"
      },
      {
        "model": "unisphere for powermax",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "dell",
        "version": "9.2.3.15"
      },
      {
        "model": "dell unisphere for powermax",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      },
      {
        "model": "dell unisphere for powermax virtual appliance",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      },
      {
        "model": "dell solutions enabler",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      },
      {
        "model": "solutions enabler virtual appliance",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      },
      {
        "model": "vasa",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      },
      {
        "model": "dell powermax os",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      },
      {
        "model": "unisphere 360",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      },
      {
        "model": "evasa provider virtual appliance",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30c7\u30eb",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016149"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-31233"
      }
    ]
  },
  "cve": "CVE-2022-31233",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.0,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.1,
            "id": "CVE-2022-31233",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "security_alert@emc.com",
            "availabilityImpact": "NONE",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 2.1,
            "id": "CVE-2022-31233",
            "impactScore": 4.2,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Adjacent Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.0,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-31233",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-31233",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "security_alert@emc.com",
            "id": "CVE-2022-31233",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-31233",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202206-2818",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016149"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-2818"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-31233"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-31233"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Unisphere for PowerMax versions before 9.2.3.15 contain a privilege escalation vulnerability. An adjacent malicious user may potentially exploit this vulnerability to escalate their privileges and access functionalities they do not have access to. eVASA Provider Virtual Appliance , Dell Solutions Enabler , Solutions Enabler Virtual Appliance Multiple Dell products are vulnerable to incorrect movement of resources between regions.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Dell EMC Unisphere for PowerMax is a set of graphical management tools for PowerMax storage arrays developed by Dell. Dell EMC Unisphere for PowerMax has a security vulnerability. An attacker exploited this vulnerability to bypass the restrictions of Dell EMC Unisphere for PowerMax to elevate his privileges",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-31233"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016149"
      },
      {
        "db": "VULHUB",
        "id": "VHN-422929"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-31233"
      }
    ],
    "trust": 1.8
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-31233",
        "trust": 3.4
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016149",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-2818",
        "trust": 0.7
      },
      {
        "db": "VULHUB",
        "id": "VHN-422929",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-31233",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-422929"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-31233"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016149"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-2818"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-31233"
      }
    ]
  },
  "id": "VAR-202206-2277",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-422929"
      }
    ],
    "trust": 0.628721285
  },
  "last_update_date": "2024-08-14T14:02:31.725000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-669",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-602",
        "trust": 1.0
      },
      {
        "problemtype": "Incorrect resource movement between regions (CWE-669) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-422929"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016149"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-31233"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.6,
        "url": "https://www.dell.com/support/kbdoc/000200975"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-31233"
      },
      {
        "trust": 0.6,
        "url": "https://vigilance.fr/vulnerability/dell-unisphere-for-powermax-privilege-escalation-38686"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-31233/"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-422929"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-31233"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016149"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-2818"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-31233"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-422929"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-31233"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016149"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-2818"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-31233"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-08-31T00:00:00",
        "db": "VULHUB",
        "id": "VHN-422929"
      },
      {
        "date": "2022-08-31T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-31233"
      },
      {
        "date": "2023-10-02T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-016149"
      },
      {
        "date": "2022-06-29T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202206-2818"
      },
      {
        "date": "2022-08-31T20:15:08.627000",
        "db": "NVD",
        "id": "CVE-2022-31233"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-09-07T00:00:00",
        "db": "VULHUB",
        "id": "VHN-422929"
      },
      {
        "date": "2022-08-31T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-31233"
      },
      {
        "date": "2023-10-02T08:11:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-016149"
      },
      {
        "date": "2022-09-08T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202206-2818"
      },
      {
        "date": "2022-09-07T16:47:34.793000",
        "db": "NVD",
        "id": "CVE-2022-31233"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote or local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-2818"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Vulnerability in incorrect movement of resources between regions in multiple Dell products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-016149"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202206-2818"
      }
    ],
    "trust": 0.6
  }
}

CVE-2020-5345 (GCVE-0-2020-5345)
Vulnerability from cvelistv5
Published
2020-06-23 20:00
Modified
2024-09-17 01:51
CWE
  • CWE-602 - Client-Side Enforcement of Server-Side Security
Summary
Dell EMC Unisphere for PowerMax versions prior to 9.1.0.17, Dell EMC Unisphere for PowerMax Virtual Appliance versions prior to 9.1.0.17, and PowerMax OS Release 5978 contain an authorization bypass vulnerability. An authenticated malicious user may potentially execute commands to alter or stop database statistics.
Impacted products
Vendor Product Version
Dell Unisphere for PowerMax Version: unspecified   < 9.1.0.17
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T08:30:23.278Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/security/en-us/details/544585/DSA-2020-065-Dell-EMC-Unisphere-for-PowerMax-Dell-EMC-Unisphere-for-PowerMax-Virtual-Appliance"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unisphere for PowerMax",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "9.1.0.17",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2020-06-18T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unisphere for PowerMax versions prior to 9.1.0.17, Dell EMC Unisphere for PowerMax Virtual Appliance versions prior to 9.1.0.17, and PowerMax OS Release 5978 contain an authorization bypass vulnerability. An authenticated malicious user may potentially execute commands to alter or stop database statistics."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:N/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-602",
              "description": "CWE-602: Client-Side Enforcement of Server-Side Security",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-06-23T20:00:17",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/security/en-us/details/544585/DSA-2020-065-Dell-EMC-Unisphere-for-PowerMax-Dell-EMC-Unisphere-for-PowerMax-Virtual-Appliance"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2020-06-18",
          "ID": "CVE-2020-5345",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unisphere for PowerMax",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "9.1.0.17"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unisphere for PowerMax versions prior to 9.1.0.17, Dell EMC Unisphere for PowerMax Virtual Appliance versions prior to 9.1.0.17, and PowerMax OS Release 5978 contain an authorization bypass vulnerability. An authenticated malicious user may potentially execute commands to alter or stop database statistics."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6.4,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:N/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-602: Client-Side Enforcement of Server-Side Security"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/security/en-us/details/544585/DSA-2020-065-Dell-EMC-Unisphere-for-PowerMax-Dell-EMC-Unisphere-for-PowerMax-Virtual-Appliance",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/security/en-us/details/544585/DSA-2020-065-Dell-EMC-Unisphere-for-PowerMax-Dell-EMC-Unisphere-for-PowerMax-Virtual-Appliance"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2020-5345",
    "datePublished": "2020-06-23T20:00:17.264990Z",
    "dateReserved": "2020-01-03T00:00:00",
    "dateUpdated": "2024-09-17T01:51:14.465Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-21531 (GCVE-0-2021-21531)
Vulnerability from cvelistv5
Published
2021-04-30 21:10
Modified
2024-09-17 03:48
CWE
  • CWE-602 - Client-Side Enforcement of Server-Side Security
Summary
Dell Unisphere for PowerMax versions prior to 9.2.1.6 contain an Authorization Bypass Vulnerability. A local authenticated malicious user with monitor role may exploit this vulnerability to perform unauthorized actions.
References
Impacted products
Vendor Product Version
Dell Unisphere for PowerMax Version: unspecified   < 9.2.1.6
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:16:22.985Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/000184565"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unisphere for PowerMax",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "9.2.1.6",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-03-24T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell Unisphere for PowerMax versions prior to 9.2.1.6 contain an Authorization Bypass Vulnerability. A local authenticated malicious user with monitor role may exploit this vulnerability to perform unauthorized actions."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-602",
              "description": "CWE-602: Client-Side Enforcement of Server-Side Security",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-04-30T21:10:18",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/000184565"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-03-24",
          "ID": "CVE-2021-21531",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unisphere for PowerMax",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "9.2.1.6"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell Unisphere for PowerMax versions prior to 9.2.1.6 contain an Authorization Bypass Vulnerability. A local authenticated malicious user with monitor role may exploit this vulnerability to perform unauthorized actions."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 8.1,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-602: Client-Side Enforcement of Server-Side Security"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/000184565",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/000184565"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-21531",
    "datePublished": "2021-04-30T21:10:18.600627Z",
    "dateReserved": "2021-01-04T00:00:00",
    "dateUpdated": "2024-09-17T03:48:26.799Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-27686 (GCVE-0-2025-27686)
Vulnerability from cvelistv5
Published
2025-04-07 13:23
Modified
2025-04-07 13:58
CWE
  • CWE-90 - Improper Neutralization of Special Elements used in an LDAP Query ('LDAP Injection')
Summary
Dell Unisphere for PowerMax, version(s) prior to 10.2.0.9 and PowerMax version(s) prior to PowerMax 9.2.4.15, contain an Improper Neutralization of Special Elements used in an LDAP Query ('LDAP Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Script injection.
Impacted products
Vendor Product Version
Dell Unisphere for PowerMax Version: N/A   
Version: N/A   
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-27686",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-07T13:57:50.416072Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-07T13:58:27.666Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Unisphere for PowerMax",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "9.2.4.15",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "10.2.0.9",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-03-31T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Unisphere for PowerMax, version(s) prior to 10.2.0.9 and PowerMax version(s) prior to PowerMax 9.2.4.15, contain an Improper Neutralization of Special Elements used in an LDAP Query (\u0027LDAP Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Script injection.\u003cbr\u003e"
            }
          ],
          "value": "Dell Unisphere for PowerMax, version(s) prior to 10.2.0.9 and PowerMax version(s) prior to PowerMax 9.2.4.15, contain an Improper Neutralization of Special Elements used in an LDAP Query (\u0027LDAP Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Script injection."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 2.7,
            "baseSeverity": "LOW",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-90",
              "description": "CWE-90: Improper Neutralization of Special Elements used in an LDAP Query (\u0027LDAP Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-07T13:23:08.166Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-ao/000302223/dsa-2025-111-dell-powermaxos-dell-powermax-eem-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-unisphere-360-dell-solutions-enabler-and-dell-solutions-enabler-virtual-appliance-security-update-for-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-27686",
    "datePublished": "2025-04-07T13:23:08.166Z",
    "dateReserved": "2025-03-05T07:33:28.314Z",
    "dateUpdated": "2025-04-07T13:58:27.666Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-35170 (GCVE-0-2020-35170)
Vulnerability from cvelistv5
Published
2021-01-05 21:40
Modified
2024-09-17 04:04
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Summary
Dell EMC Unisphere for PowerMax versions prior to 9.1.0.9, Dell EMC Unisphere for PowerMax versions prior to 9.0.2.16, and Dell EMC PowerMax OS 5978.221.221 and 5978.479.479 contain a Cross-Site Scripting (XSS) vulnerability. An authenticated malicious user may potentially exploit this vulnerability to inject javascript code and affect other authenticated users’ sessions.
References
Impacted products
Vendor Product Version
Dell Unisphere for PowerMax Version: unspecified   < 9.1.0.24
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T17:02:06.700Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/000181212"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unisphere for PowerMax",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "9.1.0.24",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2020-12-17T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unisphere for PowerMax versions prior to 9.1.0.9, Dell EMC Unisphere for PowerMax versions prior to 9.0.2.16, and Dell EMC PowerMax OS 5978.221.221 and 5978.479.479 contain a Cross-Site Scripting (XSS) vulnerability. An authenticated malicious user may potentially exploit this vulnerability to inject javascript code and affect other authenticated users\u2019 sessions."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-05T21:40:26",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/000181212"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2020-12-17",
          "ID": "CVE-2020-35170",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unisphere for PowerMax",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "9.1.0.24"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unisphere for PowerMax versions prior to 9.1.0.9, Dell EMC Unisphere for PowerMax versions prior to 9.0.2.16, and Dell EMC PowerMax OS 5978.221.221 and 5978.479.479 contain a Cross-Site Scripting (XSS) vulnerability. An authenticated malicious user may potentially exploit this vulnerability to inject javascript code and affect other authenticated users\u2019 sessions."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6.3,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/000181212",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/000181212"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2020-35170",
    "datePublished": "2021-01-05T21:40:26.349130Z",
    "dateReserved": "2020-12-11T00:00:00",
    "dateUpdated": "2024-09-17T04:04:45.256Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-36338 (GCVE-0-2021-36338)
Vulnerability from cvelistv5
Published
2022-01-21 20:15
Modified
2024-09-16 22:01
CWE
  • CWE-602 - Client-Side Enforcement of Server-Side Security
Summary
Unisphere for PowerMax versions prior to 9.2.2.2 contains a privilege escalation vulnerability. An adjacent malicious user could potentially exploit this vulnerability to escalate their privileges and access functionalities they do not have access to. CVE-2022-31233 addresses the partial fix in CVE-2021-36338.
References
Impacted products
Vendor Product Version
Dell Unisphere for PowerMax Version: unspecified   < 9.2.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:54:51.435Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/000194640"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unisphere for PowerMax",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "9.2.2.2",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-12-19T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Unisphere for PowerMax versions prior to 9.2.2.2 contains a privilege escalation vulnerability. An adjacent malicious user could potentially exploit this vulnerability to escalate their privileges and access functionalities they do not have access to. CVE-2022-31233 addresses the partial fix in CVE-2021-36338."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-602",
              "description": "CWE-602: Client-Side Enforcement of Server-Side Security",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-31T20:05:13",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/000194640"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-12-19",
          "ID": "CVE-2021-36338",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unisphere for PowerMax",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "9.2.2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Unisphere for PowerMax versions prior to 9.2.2.2 contains a privilege escalation vulnerability. An adjacent malicious user could potentially exploit this vulnerability to escalate their privileges and access functionalities they do not have access to. CVE-2022-31233 addresses the partial fix in CVE-2021-36338."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6.3,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-602: Client-Side Enforcement of Server-Side Security"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/000194640",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/000194640"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-36338",
    "datePublished": "2022-01-21T20:15:17.003707Z",
    "dateReserved": "2021-07-08T00:00:00",
    "dateUpdated": "2024-09-16T22:01:34.577Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-34397 (GCVE-0-2022-34397)
Vulnerability from cvelistv5
Published
2023-02-13 09:06
Modified
2025-03-21 14:49
CWE
  • CWE-863 - Incorrect Authorization
Summary
Dell Unisphere for PowerMax vApp, VASA Provider vApp, and Solution Enabler vApp version 10.0.0.5 and below contains an authorization bypass vulnerability, allowing users to perform actions in which they are not authorized.
Impacted products
Vendor Product Version
Dell Unisphere for PowerMax Version: 0   < 10.0.0.5
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:07:16.297Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000207177/dsa-2022-340-dell-unisphere-for-powermax-dell-unisphere-for-powermax-vapp-dell-solutions-enabler-vapp-dell-unisphere-360-dell-vasa-provider-vapp-and-dell-powermax-emb-mgmt-security-update-for-multiple-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-34397",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-21T14:49:21.304023Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-21T14:49:28.192Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Unisphere for PowerMax",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "10.0.0.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2023-01-04T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell Unisphere for PowerMax vApp, VASA Provider vApp, and Solution Enabler vApp version 10.0.0.5 and below contains an authorization bypass vulnerability, allowing users to perform actions in which they are not authorized.\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nDell Unisphere for PowerMax vApp, VASA Provider vApp, and Solution Enabler vApp version 10.0.0.5 and below contains an authorization bypass vulnerability, allowing users to perform actions in which they are not authorized.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:L/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-863",
              "description": "CWE-863: Incorrect Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-31T05:03:28.028Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000207177/dsa-2022-340-dell-unisphere-for-powermax-dell-unisphere-for-powermax-vapp-dell-solutions-enabler-vapp-dell-unisphere-360-dell-vasa-provider-vapp-and-dell-powermax-emb-mgmt-security-update-for-multiple-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2022-34397",
    "datePublished": "2023-02-13T09:06:03.573Z",
    "dateReserved": "2022-06-23T18:55:17.096Z",
    "dateUpdated": "2025-03-21T14:49:28.192Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-18588 (GCVE-0-2019-18588)
Vulnerability from cvelistv5
Published
2020-01-10 18:20
Modified
2024-09-17 02:21
Severity ?
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Summary
Dell EMC Unisphere for PowerMax versions prior to 9.1.0.9, Dell EMC Unisphere for PowerMax versions prior to 9.0.2.16, and Dell EMC PowerMax OS 5978.221.221 and 5978.479.479 contain a Cross-Site Scripting (XSS) vulnerability. An authenticated malicious user may potentially exploit this vulnerability to inject javascript code and affect other authenticated users' sessions.
Impacted products
Vendor Product Version
Dell Unisphere for PowerMax Version: unspecified   < 9.1.0.9 and 9.0.2.16
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T01:54:14.490Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/security/en-us/details/539808/DSA-2019-193-Dell-EMC-Unisphere-for-PowerMax-and-Dell-EMC-PowerMax-Embedded-Management-Cross-Site"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unisphere for PowerMax",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "9.1.0.9 and 9.0.2.16",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2019-12-12T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Unisphere for PowerMax versions prior to 9.1.0.9, Dell EMC Unisphere for PowerMax versions prior to 9.0.2.16, and Dell EMC PowerMax OS 5978.221.221 and 5978.479.479 contain a Cross-Site Scripting (XSS) vulnerability. An authenticated malicious user may potentially exploit this vulnerability to inject javascript code and affect other authenticated users\u0027 sessions."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-01-10T18:20:11",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/security/en-us/details/539808/DSA-2019-193-Dell-EMC-Unisphere-for-PowerMax-and-Dell-EMC-PowerMax-Embedded-Management-Cross-Site"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2019-12-12",
          "ID": "CVE-2019-18588",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unisphere for PowerMax",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "9.1.0.9 and 9.0.2.16"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Unisphere for PowerMax versions prior to 9.1.0.9, Dell EMC Unisphere for PowerMax versions prior to 9.0.2.16, and Dell EMC PowerMax OS 5978.221.221 and 5978.479.479 contain a Cross-Site Scripting (XSS) vulnerability. An authenticated malicious user may potentially exploit this vulnerability to inject javascript code and affect other authenticated users\u0027 sessions."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 9,
            "baseSeverity": "Critical",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/security/en-us/details/539808/DSA-2019-193-Dell-EMC-Unisphere-for-PowerMax-and-Dell-EMC-PowerMax-Embedded-Management-Cross-Site",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/security/en-us/details/539808/DSA-2019-193-Dell-EMC-Unisphere-for-PowerMax-and-Dell-EMC-PowerMax-Embedded-Management-Cross-Site"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2019-18588",
    "datePublished": "2020-01-10T18:20:11.404654Z",
    "dateReserved": "2019-10-29T00:00:00",
    "dateUpdated": "2024-09-17T02:21:01.089Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-31233 (GCVE-0-2022-31233)
Vulnerability from cvelistv5
Published
2022-08-31 20:05
Modified
2024-09-16 16:37
CWE
  • CWE-602 - Client-Side Enforcement of Server-Side Security
Summary
Unisphere for PowerMax versions before 9.2.3.15 contain a privilege escalation vulnerability. An adjacent malicious user may potentially exploit this vulnerability to escalate their privileges and access functionalities they do not have access to.
References
Impacted products
Vendor Product Version
Dell Unisphere for PowerMax Version: unspecified   < 9.2.3.15
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T07:11:39.847Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/000200975"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unisphere for PowerMax",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "9.2.3.15",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-06-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Unisphere for PowerMax versions before 9.2.3.15 contain a privilege escalation vulnerability. An adjacent malicious user may potentially exploit this vulnerability to escalate their privileges and access functionalities they do not have access to."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-602",
              "description": "CWE-602: Client-Side Enforcement of Server-Side Security",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-31T20:05:14",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/000200975"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2022-06-27",
          "ID": "CVE-2022-31233",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unisphere for PowerMax",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "9.2.3.15"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Unisphere for PowerMax versions before 9.2.3.15 contain a privilege escalation vulnerability. An adjacent malicious user may potentially exploit this vulnerability to escalate their privileges and access functionalities they do not have access to."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6.3,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-602: Client-Side Enforcement of Server-Side Security"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/000200975",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/000200975"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2022-31233",
    "datePublished": "2022-08-31T20:05:14.863050Z",
    "dateReserved": "2022-05-19T00:00:00",
    "dateUpdated": "2024-09-16T16:37:57.813Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",