Vulnerabilites related to SSH - Tectia Server
CVE-2025-32942 (GCVE-0-2025-32942)
Vulnerability from cvelistv5
Published
2025-10-02 00:00
Modified
2025-10-02 19:47
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-670 - Always-Incorrect Control Flow Implementation
Summary
SSH Tectia Server before 6.6.6 sometimes allows attackers to read and alter a user's session traffic.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
SSH | Tectia Server |
Version: 0 ≤ Version: 6.5.0 ≤ Version: 6.6.0 ≤ Version: 6.7.0 ≤ |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-32942", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-10-02T19:31:43.027276Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-10-02T19:47:50.861Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Tectia Server", "vendor": "SSH", "versions": [ { "lessThan": "6.4.21", "status": "affected", "version": "0", "versionType": "semver" }, { "lessThan": "6.5.3", "status": "affected", "version": "6.5.0", "versionType": "semver" }, { "lessThan": "6.6.6", "status": "affected", "version": "6.6.0", "versionType": "semver" }, { "lessThan": "7.0.0", "status": "affected", "version": "6.7.0", "versionType": "semver" } ] } ], "cpeApplicability": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:ssh:tectia_server:*:*:*:*:*:*:*:*", "versionEndExcluding": "6.4.21", "vulnerable": true }, { "criteria": "cpe:2.3:a:ssh:tectia_server:*:*:*:*:*:*:*:*", "versionEndExcluding": "6.5.3", "versionStartIncluding": "6.5.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:ssh:tectia_server:*:*:*:*:*:*:*:*", "versionEndExcluding": "6.6.6", "versionStartIncluding": "6.6.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:ssh:tectia_server:*:*:*:*:*:*:*:*", "versionEndExcluding": "7.0.0", "versionStartIncluding": "6.7.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "descriptions": [ { "lang": "en", "value": "SSH Tectia Server before 6.6.6 sometimes allows attackers to read and alter a user\u0027s session traffic." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:L/I:H/A:L", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-670", "description": "CWE-670 Always-Incorrect Control Flow Implementation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-10-02T19:39:04.816Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://info.ssh.com/tectia-vulnerability-cve-2025-32942" } ], "x_generator": { "engine": "enrichogram 0.0.1" } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2025-32942", "datePublished": "2025-10-02T00:00:00.000Z", "dateReserved": "2025-04-14T00:00:00.000Z", "dateUpdated": "2025-10-02T19:47:50.861Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }