Vulnerabilites related to Schneider Electric - SpaceLogic C-Bus Home Controller
CVE-2022-34753 (GCVE-0-2022-34753)
Vulnerability from cvelistv5
Published
2022-07-13 21:10
Modified
2024-09-16 19:14
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-78 - OS Command Injection
Summary
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller (5200WHC2), formerly known as C-Bus Wiser Homer Controller MK2 (V1.31.460 and prior)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | SpaceLogic C-Bus Home Controller |
Version: 5200WHC2 < V1.31.460 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T09:22:09.210Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-02_SpaceLogic-C-Bus-Home-Controller-Wiser_MK2_Security_Notification.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://packetstormsecurity.com/files/167783/Schneider-Electric-SpaceLogic-C-Bus-Home-Controller-5200WHC2-Remote-Root.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SpaceLogic C-Bus Home Controller", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V1.31.460", "status": "affected", "version": "5200WHC2", "versionType": "custom" } ] } ], "datePublic": "2022-07-12T00:00:00", "descriptions": [ { "lang": "en", "value": "A CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller (5200WHC2), formerly known as C-Bus Wiser Homer Controller MK2 (V1.31.460 and prior)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 OS Command Injection", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-07-21T21:06:29", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-02_SpaceLogic-C-Bus-Home-Controller-Wiser_MK2_Security_Notification.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "http://packetstormsecurity.com/files/167783/Schneider-Electric-SpaceLogic-C-Bus-Home-Controller-5200WHC2-Remote-Root.html" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "DATE_PUBLIC": "2022-07-12T11:00:00.000Z", "ID": "CVE-2022-34753", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SpaceLogic C-Bus Home Controller", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "5200WHC2", "version_value": "V1.31.460" } ] } } ] }, "vendor_name": "Schneider Electric" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller (5200WHC2), formerly known as C-Bus Wiser Homer Controller MK2 (V1.31.460 and prior)" } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-78 OS Command Injection" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-02_SpaceLogic-C-Bus-Home-Controller-Wiser_MK2_Security_Notification.pdf", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-02_SpaceLogic-C-Bus-Home-Controller-Wiser_MK2_Security_Notification.pdf" }, { "name": "http://packetstormsecurity.com/files/167783/Schneider-Electric-SpaceLogic-C-Bus-Home-Controller-5200WHC2-Remote-Root.html", "refsource": "MISC", "url": "http://packetstormsecurity.com/files/167783/Schneider-Electric-SpaceLogic-C-Bus-Home-Controller-5200WHC2-Remote-Root.html" } ] }, "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-34753", "datePublished": "2022-07-13T21:10:25.007418Z", "dateReserved": "2022-06-28T00:00:00", "dateUpdated": "2024-09-16T19:14:26.516Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }