cve-2022-40631
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SCALANCE X200-4P IRT |
Version: All versions < V5.5.0 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T12:21:46.592Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-501891.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SCALANCE X200-4P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X201-3P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X202-2IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X202-2P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X204-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X204-2FM", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X204-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X204-2LD TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X204-2TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X204IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X206-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X206-1LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X208PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X212-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X212-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X224", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE XF201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE XF202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE XF204-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE XF204-2BA IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE XF204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE XF206-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE XF208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SIPLUS NET SCALANCE X202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c V5.5.0), SCALANCE X201-3P IRT (All versions \u003c V5.5.0), SCALANCE X201-3P IRT PRO (All versions \u003c V5.5.0), SCALANCE X202-2IRT (All versions \u003c V5.5.0), SCALANCE X202-2P IRT (All versions \u003c V5.5.0), SCALANCE X202-2P IRT PRO (All versions \u003c V5.5.0), SCALANCE X204-2 (All versions \u003c V5.2.5), SCALANCE X204-2FM (All versions \u003c V5.2.5), SCALANCE X204-2LD (All versions \u003c V5.2.5), SCALANCE X204-2LD TS (All versions \u003c V5.2.5), SCALANCE X204-2TS (All versions \u003c V5.2.5), SCALANCE X204IRT (All versions \u003c V5.5.0), SCALANCE X204IRT PRO (All versions \u003c V5.5.0), SCALANCE X206-1 (All versions \u003c V5.2.5), SCALANCE X206-1LD (All versions \u003c V5.2.5), SCALANCE X208 (All versions \u003c V5.2.5), SCALANCE X208PRO (All versions \u003c V5.2.5), SCALANCE X212-2 (All versions \u003c V5.2.5), SCALANCE X212-2LD (All versions \u003c V5.2.5), SCALANCE X216 (All versions \u003c V5.2.5), SCALANCE X224 (All versions \u003c V5.2.5), SCALANCE XF201-3P IRT (All versions \u003c V5.5.0), SCALANCE XF202-2P IRT (All versions \u003c V5.5.0), SCALANCE XF204 (All versions \u003c V5.2.5), SCALANCE XF204-2 (All versions \u003c V5.2.5), SCALANCE XF204-2BA IRT (All versions \u003c V5.5.0), SCALANCE XF204IRT (All versions \u003c V5.5.0), SCALANCE XF206-1 (All versions \u003c V5.2.5), SCALANCE XF208 (All versions \u003c V5.2.5), SIPLUS NET SCALANCE X202-2P IRT (All versions \u003c V5.5.0). There is a cross-site scripting vulnerability on the affected devices, that if used by a threat actor, it could result in session hijacking." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-10-11T00:00:00", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-501891.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-40631", "datePublished": "2022-10-11T00:00:00", "dateReserved": "2022-09-13T00:00:00", "dateUpdated": "2024-08-03T12:21:46.592Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-29054
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SCALANCE X200-4P IRT |
Version: All versions < V5.5.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:00:14.631Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-479249.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SCALANCE X200-4P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE X202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT PRO (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT PRO (All versions \u003c V5.5.2), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT PRO (All versions \u003c V5.5.2), SCALANCE XF201-3P IRT (All versions \u003c V5.5.2), SCALANCE XF202-2P IRT (All versions \u003c V5.5.2), SCALANCE XF204-2BA IRT (All versions \u003c V5.5.2), SCALANCE XF204IRT (All versions \u003c V5.5.2), SIPLUS NET SCALANCE X202-2P IRT (All versions \u003c V5.5.2). The SSH server on affected devices is configured to offer weak ciphers by default.\r\n\r\nThis could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data\r\npassed over the connection between legitimate clients and the affected device." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H/E:P/RL:U/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-326", "description": "CWE-326: Inadequate Encryption Strength", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-11T09:03:08.813Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-479249.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-29054", "datePublished": "2023-04-11T09:03:08.813Z", "dateReserved": "2023-03-30T12:04:26.539Z", "dateUpdated": "2024-08-02T14:00:14.631Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
var-202304-0694
Vulnerability from variot
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2P IRT (All versions < V5.5.2), SCALANCE X202-2P IRT PRO (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT PRO (All versions < V5.5.2), SCALANCE XF201-3P IRT (All versions < V5.5.2), SCALANCE XF202-2P IRT (All versions < V5.5.2), SCALANCE XF204-2BA IRT (All versions < V5.5.2), SCALANCE XF204IRT (All versions < V5.5.2), SIPLUS NET SCALANCE X202-2P IRT (All versions < V5.5.2). The SSH server on affected devices is configured to offer weak ciphers by default.
This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data passed over the connection between legitimate clients and the affected device. SCALANCE X200-4P IRT firmware, SCALANCE X201-3P IRT firmware, SCALANCE X201-3P IRT PRO Multiple Siemens products, including firmware, have vulnerabilities related to encryption strength.Information may be obtained and information may be tampered with
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202304-0694", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "scalance xf204irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.2" }, { "model": "scalance x201-3p irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.2" }, { "model": "scalance x204irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.2" }, { "model": "scalance xf202-2p irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.2" }, { "model": "scalance x204irt pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.2" }, { "model": "scalance xf201-3p irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.2" }, { "model": "scalance x202-2irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.2" }, { "model": "scalance x201-3p irt pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.2" }, { "model": "scalance x202-2p irt pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.2" }, { "model": "scalance xf204-2ba irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.2" }, { "model": "scalance x200-4p irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.2" }, { "model": "scalance x202-2p irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.2" }, { "model": "siplus net scalance x202-2p irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.2" }, { "model": "scalance x201-3p irt pro", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xf204irt", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x201-3p irt", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xf201-3p irt", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x200-4p irt", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xf204-2ba irt", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x204irt pro", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "siplus net scalance x202-2p irt", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance xf202-2p irt", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x202-2irt", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x202-2p irt pro", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x202-2p irt", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x204irt", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006528" }, { "db": "NVD", "id": "CVE-2023-29054" } ] }, "cve": "CVE-2023-29054", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "HIGH", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 7.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.2, "id": "CVE-2023-29054", "impactScore": 5.2, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, { "attackComplexity": "HIGH", "attackVector": "ADJACENT", "author": "productcert@siemens.com", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 1.2, "id": "CVE-2023-29054", "impactScore": 5.5, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H", "version": "3.1" }, { "attackComplexity": "High", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 7.4, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-29054", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-29054", "trust": 1.0, "value": "HIGH" }, { "author": "productcert@siemens.com", "id": "CVE-2023-29054", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2023-29054", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202304-793", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006528" }, { "db": "CNNVD", "id": "CNNVD-202304-793" }, { "db": "NVD", "id": "CVE-2023-29054" }, { "db": "NVD", "id": "CVE-2023-29054" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT PRO (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT PRO (All versions \u003c V5.5.2), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT PRO (All versions \u003c V5.5.2), SCALANCE XF201-3P IRT (All versions \u003c V5.5.2), SCALANCE XF202-2P IRT (All versions \u003c V5.5.2), SCALANCE XF204-2BA IRT (All versions \u003c V5.5.2), SCALANCE XF204IRT (All versions \u003c V5.5.2), SIPLUS NET SCALANCE X202-2P IRT (All versions \u003c V5.5.2). The SSH server on affected devices is configured to offer weak ciphers by default. \r\n\r\nThis could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data\r\npassed over the connection between legitimate clients and the affected device. SCALANCE X200-4P IRT firmware, SCALANCE X201-3P IRT firmware, SCALANCE X201-3P IRT PRO Multiple Siemens products, including firmware, have vulnerabilities related to encryption strength.Information may be obtained and information may be tampered with", "sources": [ { "db": "NVD", "id": "CVE-2023-29054" }, { "db": "JVNDB", "id": "JVNDB-2023-006528" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-29054", "trust": 3.2 }, { "db": "SIEMENS", "id": "SSA-479249", "trust": 2.4 }, { "db": "ICS CERT", "id": "ICSA-23-103-05", "trust": 0.8 }, { "db": "JVN", "id": "JVNVU94715153", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2023-006528", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202304-793", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006528" }, { "db": "CNNVD", "id": "CNNVD-202304-793" }, { "db": "NVD", "id": "CVE-2023-29054" } ] }, "id": "VAR-202304-0694", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.5252349089999999 }, "last_update_date": "2024-08-14T12:12:41.046000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Siemens SCALANCE Fixes for encryption problem vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=234432" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-793" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-326", "trust": 1.0 }, { "problemtype": "Inappropriate cryptographic strength (CWE-326) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006528" }, { "db": "NVD", "id": "CVE-2023-29054" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-479249.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu94715153/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-29054" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-05" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-29054/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006528" }, { "db": "CNNVD", "id": "CNNVD-202304-793" }, { "db": "NVD", "id": "CVE-2023-29054" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2023-006528" }, { "db": "CNNVD", "id": "CNNVD-202304-793" }, { "db": "NVD", "id": "CVE-2023-29054" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-11-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-006528" }, { "date": "2023-04-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-793" }, { "date": "2023-04-11T10:15:18.517000", "db": "NVD", "id": "CVE-2023-29054" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-11-15T05:05:00", "db": "JVNDB", "id": "JVNDB-2023-006528" }, { "date": "2023-04-21T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-793" }, { "date": "2023-04-20T18:43:29.747000", "db": "NVD", "id": "CVE-2023-29054" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-793" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cryptographic strength vulnerabilities in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006528" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "encryption problem", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-793" } ], "trust": 0.6 } }
var-202210-0551
Vulnerability from variot
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.0), SCALANCE X201-3P IRT (All versions < V5.5.0), SCALANCE X201-3P IRT PRO (All versions < V5.5.0), SCALANCE X202-2IRT (All versions < V5.5.0), SCALANCE X202-2P IRT (All versions < V5.5.0), SCALANCE X202-2P IRT PRO (All versions < V5.5.0), SCALANCE X204-2 (All versions < V5.2.5), SCALANCE X204-2FM (All versions < V5.2.5), SCALANCE X204-2LD (All versions < V5.2.5), SCALANCE X204-2LD TS (All versions < V5.2.5), SCALANCE X204-2TS (All versions < V5.2.5), SCALANCE X204IRT (All versions < V5.5.0), SCALANCE X204IRT PRO (All versions < V5.5.0), SCALANCE X206-1 (All versions < V5.2.5), SCALANCE X206-1LD (All versions < V5.2.5), SCALANCE X208 (All versions < V5.2.5), SCALANCE X208PRO (All versions < V5.2.5), SCALANCE X212-2 (All versions < V5.2.5), SCALANCE X212-2LD (All versions < V5.2.5), SCALANCE X216 (All versions < V5.2.5), SCALANCE X224 (All versions < V5.2.5), SCALANCE XF201-3P IRT (All versions < V5.5.0), SCALANCE XF202-2P IRT (All versions < V5.5.0), SCALANCE XF204 (All versions < V5.2.5), SCALANCE XF204-2 (All versions < V5.2.5), SCALANCE XF204-2BA IRT (All versions < V5.5.0), SCALANCE XF204IRT (All versions < V5.5.0), SCALANCE XF206-1 (All versions < V5.2.5), SCALANCE XF208 (All versions < V5.2.5), SIPLUS NET SCALANCE X202-2P IRT (All versions < V5.5.0). There is a cross-site scripting vulnerability on the affected devices, that if used by a threat actor, it could result in session hijacking. scalance x200-4p irt firmware, SCALANCE X201-3P IRT firmware, SCALANCE X201-3P IRT PRO Multiple Siemens products such as firmware contain a cross-site scripting vulnerability.Information may be obtained and information may be tampered with
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202210-0551", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "scalance x208", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf204", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x224", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf201-3p irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x201-3p irt pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x204-2ts", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x206-1ld", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x216", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf206-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf204irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x204-2fm", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204-2ld", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x212-2ld", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance xf202-2p irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance xf204-2ba irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x204irt pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance xf208", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x204irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x202-2irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x206-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x200-4p irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance xf204-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x202-2p irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x202-2p irt pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "siplus net scalance x202-2p irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x204-2ld ts", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x201-3p irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.5.0" }, { "model": "scalance x208pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x212-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.5" }, { "model": "scalance x201-3p irt", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x201-3p irt pro", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x204-2ts", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x204irt pro", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x206-1ld", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x202-2irt", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x208pro", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x212-2ld", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x200-4p irt", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x202-2p irt", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x202-2p irt pro", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x204-2ld ts", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x204irt", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x216", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x204-2fm", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x206-1", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x204-2ld", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x208", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x204-2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "scalance x212-2", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-018712" }, { "db": "NVD", "id": "CVE-2022-40631" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported this vulnerability to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-504" } ], "trust": 0.6 }, "cve": "CVE-2022-40631", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 2.8, "id": "CVE-2022-40631", "impactScore": 2.7, "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 6.1, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "CVE-2022-40631", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-40631", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2022-40631", "trust": 0.8, "value": "Medium" }, { "author": "CNNVD", "id": "CNNVD-202210-504", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-018712" }, { "db": "CNNVD", "id": "CNNVD-202210-504" }, { "db": "NVD", "id": "CVE-2022-40631" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c V5.5.0), SCALANCE X201-3P IRT (All versions \u003c V5.5.0), SCALANCE X201-3P IRT PRO (All versions \u003c V5.5.0), SCALANCE X202-2IRT (All versions \u003c V5.5.0), SCALANCE X202-2P IRT (All versions \u003c V5.5.0), SCALANCE X202-2P IRT PRO (All versions \u003c V5.5.0), SCALANCE X204-2 (All versions \u003c V5.2.5), SCALANCE X204-2FM (All versions \u003c V5.2.5), SCALANCE X204-2LD (All versions \u003c V5.2.5), SCALANCE X204-2LD TS (All versions \u003c V5.2.5), SCALANCE X204-2TS (All versions \u003c V5.2.5), SCALANCE X204IRT (All versions \u003c V5.5.0), SCALANCE X204IRT PRO (All versions \u003c V5.5.0), SCALANCE X206-1 (All versions \u003c V5.2.5), SCALANCE X206-1LD (All versions \u003c V5.2.5), SCALANCE X208 (All versions \u003c V5.2.5), SCALANCE X208PRO (All versions \u003c V5.2.5), SCALANCE X212-2 (All versions \u003c V5.2.5), SCALANCE X212-2LD (All versions \u003c V5.2.5), SCALANCE X216 (All versions \u003c V5.2.5), SCALANCE X224 (All versions \u003c V5.2.5), SCALANCE XF201-3P IRT (All versions \u003c V5.5.0), SCALANCE XF202-2P IRT (All versions \u003c V5.5.0), SCALANCE XF204 (All versions \u003c V5.2.5), SCALANCE XF204-2 (All versions \u003c V5.2.5), SCALANCE XF204-2BA IRT (All versions \u003c V5.5.0), SCALANCE XF204IRT (All versions \u003c V5.5.0), SCALANCE XF206-1 (All versions \u003c V5.2.5), SCALANCE XF208 (All versions \u003c V5.2.5), SIPLUS NET SCALANCE X202-2P IRT (All versions \u003c V5.5.0). There is a cross-site scripting vulnerability on the affected devices, that if used by a threat actor, it could result in session hijacking. scalance x200-4p irt firmware, SCALANCE X201-3P IRT firmware, SCALANCE X201-3P IRT PRO Multiple Siemens products such as firmware contain a cross-site scripting vulnerability.Information may be obtained and information may be tampered with", "sources": [ { "db": "NVD", "id": "CVE-2022-40631" }, { "db": "JVNDB", "id": "JVNDB-2022-018712" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-40631", "trust": 3.2 }, { "db": "SIEMENS", "id": "SSA-501891", "trust": 2.4 }, { "db": "ICS CERT", "id": "ICSA-22-286-15", "trust": 1.4 }, { "db": "JVN", "id": "JVNVU92214181", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2022-018712", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202210-504", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-018712" }, { "db": "CNNVD", "id": "CNNVD-202210-504" }, { "db": "NVD", "id": "CVE-2022-40631" } ] }, "id": "VAR-202210-0551", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.5104343616666666 }, "last_update_date": "2024-08-14T12:41:47.096000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Siemens Scalance X-200 Fixes for cross-site scripting vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=210803" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-504" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-79", "trust": 1.0 }, { "problemtype": "Cross-site scripting (CWE-79) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-018712" }, { "db": "NVD", "id": "CVE-2022-40631" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-501891.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu92214181/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-40631" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-286-15" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-286-15" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-40631/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-018712" }, { "db": "CNNVD", "id": "CNNVD-202210-504" }, { "db": "NVD", "id": "CVE-2022-40631" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2022-018712" }, { "db": "CNNVD", "id": "CNNVD-202210-504" }, { "db": "NVD", "id": "CVE-2022-40631" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-10-23T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-018712" }, { "date": "2022-10-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202210-504" }, { "date": "2022-10-11T11:15:10.997000", "db": "NVD", "id": "CVE-2022-40631" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-10-23T02:34:00", "db": "JVNDB", "id": "JVNDB-2022-018712" }, { "date": "2022-10-17T00:00:00", "db": "CNNVD", "id": "CNNVD-202210-504" }, { "date": "2022-10-14T17:07:54.777000", "db": "NVD", "id": "CVE-2022-40631" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-504" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cross-site scripting vulnerability in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-018712" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "XSS", "sources": [ { "db": "CNNVD", "id": "CNNVD-202210-504" } ], "trust": 0.6 } }