cve-2020-7580
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC Automation Tool |
Version: All versions < V4 SP2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T09:33:19.492Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf" }, { "tags": [ "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC Automation Tool", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4 SP2" } ] }, { "product": "SIMATIC NET PC Software V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 14" } ] }, { "product": "SIMATIC NET PC Software V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC NET PC Software V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Upd3" } ] }, { "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0 SP1" } ] }, { "product": "SIMATIC ProSave", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V17" } ] }, { "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V21.8" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V13", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13 SP2 Update 4" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 10" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 5" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 2" } ] }, { "product": "SIMATIC STEP 7 V5", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.6 SP2 HF3" } ] }, { "product": "SIMATIC WinCC OA V3.16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.16 P018" } ] }, { "product": "SIMATIC WinCC OA V3.17", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.17 P003" } ] }, { "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 2" } ] }, { "product": "SIMATIC WinCC Runtime Professional V13", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13 SP2 Update 4" } ] }, { "product": "SIMATIC WinCC Runtime Professional V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 10" } ] }, { "product": "SIMATIC WinCC Runtime Professional V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 5" } ] }, { "product": "SIMATIC WinCC Runtime Professional V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 2" } ] }, { "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.4 SP1 Update 14" } ] }, { "product": "SIMATIC WinCC V7.5", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.5 SP1 Update 3" } ] }, { "product": "SINAMICS STARTER", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.4 HF2" } ] }, { "product": "SINAMICS Startdrive", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V16 Update 3" } ] }, { "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0 SP2" } ] }, { "product": "SINEMA Server", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP3" } ] }, { "product": "SINUMERIK ONE virtual", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V6.14" } ] }, { "product": "SINUMERIK Operate", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V6.14" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC Automation Tool (All versions \u003c V4 SP2), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Upd3), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC ProSave (All versions \u003c V17), SIMATIC S7-1500 Software Controller (All versions \u003c V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMATIC STEP 7 V5 (All versions \u003c V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions \u003c V3.16 P018), SIMATIC WinCC OA V3.17 (All versions \u003c V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions \u003c V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 3), SINAMICS STARTER (All Versions \u003c V5.4 HF2), SINAMICS Startdrive (All Versions \u003c V16 Update 3), SINEC NMS (All versions \u003c V1.0 SP2), SINEMA Server (All versions \u003c V14 SP3), SINUMERIK ONE virtual (All Versions \u003c V6.14), SINUMERIK Operate (All Versions \u003c V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-428", "description": "CWE-428: Unquoted Search Path or Element", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-13T00:00:00", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf" }, { "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-7580", "datePublished": "2020-06-10T00:00:00", "dateReserved": "2020-01-21T00:00:00", "dateUpdated": "2024-08-04T09:33:19.492Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
var-202006-1828
Vulnerability from variot
A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges. plural SIMATIC The product contains vulnerabilities in unquoted search paths or elements.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Opera Software, Opera, etc. are all products of Opera Software in Norway. Opera is a web browser, Siemens SIMATIC S7-1500, etc. are all products of German Siemens (Siemens). SIMATIC S7-1500 is a programmable logic controller. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. Code issue vulnerabilities exist in several products. This vulnerability stems from improper design or implementation problems in the code development process of network systems or products
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-1828", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic pcs neo", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic prosave", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic wincc", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "7.5" }, { "model": "simatic automatic tool", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic wincc runtime professional", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "13" }, { "model": "simatic pcs 7", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics starter commissioning tool", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic wincc open architecture", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "3.17" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic net pc", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic net pc", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic step 7", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "13" }, { "model": "simatic wincc runtime professional", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinec network management system", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic step 7", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinema server", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic step 7", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "5.6" }, { "model": "simatic wincc", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "7.4" }, { "model": "sinamics startdrive", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinumerik one virtual", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinumerik operate", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic wincc open architecture", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "3.16" }, { "model": "simatic wincc", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "7.4" }, { "model": "simatic s7-1500 software controller", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "21.8" }, { "model": "simatic step 7", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.6" }, { "model": "simatic automation tool", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic net pc software", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic pcs 7", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic pcs neo", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic prosave", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic step 7", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc oa", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime professional", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006496" }, { "db": "NVD", "id": "CVE-2020-7580" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:siemens:simatic_automation_tool", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_net_pc-software", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_pcs_7", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_pcs_neo", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_prosave", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_step_7", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_open_architecture", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_runtime_professional", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006496" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Ander Martinez of Titanium Industrial Security and INCIBE reported this vulnerability to Siemens.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-636" } ], "trust": 0.6 }, "cve": "CVE-2020-7580", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 3.9, "id": "CVE-2020-7580", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.1, "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Local", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 7.2, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "JVNDB-2020-006496", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 3.9, "id": "VHN-185705", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:L/AC:L/AU:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.8, "id": "CVE-2020-7580", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.7, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006496", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-7580", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "JVNDB-2020-006496", "trust": 0.8, "value": "Medium" }, { "author": "CNNVD", "id": "CNNVD-202006-636", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULHUB", "id": "VHN-185705", "trust": 0.1, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2020-7580", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-185705" }, { "db": "VULMON", "id": "CVE-2020-7580" }, { "db": "JVNDB", "id": "JVNDB-2020-006496" }, { "db": "CNNVD", "id": "CNNVD-202006-636" }, { "db": "NVD", "id": "CVE-2020-7580" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC Automation Tool (All versions \u003c V4 SP2), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Upd3), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC ProSave (All versions \u003c V17), SIMATIC S7-1500 Software Controller (All versions \u003c V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMATIC STEP 7 V5 (All versions \u003c V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions \u003c V3.16 P018), SIMATIC WinCC OA V3.17 (All versions \u003c V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions \u003c V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 3), SINAMICS STARTER (All Versions \u003c V5.4 HF2), SINAMICS Startdrive (All Versions \u003c V16 Update 3), SINEC NMS (All versions \u003c V1.0 SP2), SINEMA Server (All versions \u003c V14 SP3), SINUMERIK ONE virtual (All Versions \u003c V6.14), SINUMERIK Operate (All Versions \u003c V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges. plural SIMATIC The product contains vulnerabilities in unquoted search paths or elements.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Opera Software, Opera, etc. are all products of Opera Software in Norway. Opera is a web browser, Siemens SIMATIC S7-1500, etc. are all products of German Siemens (Siemens). SIMATIC S7-1500 is a programmable logic controller. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. Code issue vulnerabilities exist in several products. This vulnerability stems from improper design or implementation problems in the code development process of network systems or products", "sources": [ { "db": "NVD", "id": "CVE-2020-7580" }, { "db": "JVNDB", "id": "JVNDB-2020-006496" }, { "db": "VULHUB", "id": "VHN-185705" }, { "db": "VULMON", "id": "CVE-2020-7580" } ], "trust": 1.8 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-7580", "trust": 2.6 }, { "db": "ICS CERT", "id": "ICSA-20-161-04", "trust": 2.6 }, { "db": "SIEMENS", "id": "SSA-312271", "trust": 1.8 }, { "db": "JVN", "id": "JVNVU97501786", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2020-006496", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202006-636", "trust": 0.7 }, { "db": "AUSCERT", "id": "ESB-2020.2015", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-185705", "trust": 0.1 }, { "db": "VULMON", "id": "CVE-2020-7580", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-185705" }, { "db": "VULMON", "id": "CVE-2020-7580" }, { "db": "JVNDB", "id": "JVNDB-2020-006496" }, { "db": "CNNVD", "id": "CNNVD-202006-636" }, { "db": "NVD", "id": "CVE-2020-7580" } ] }, "id": "VAR-202006-1828", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-185705" } ], "trust": 0.6991104690909089 }, "last_update_date": "2024-11-23T20:22:32.187000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-312271:Unquoted Search Path Vulnerabilities in Windows-based Industrial Software Applications", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf" }, { "title": "Multiple Siemens Product code issue vulnerability fixes", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=121186" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=9c51f352314e5a42566d9203d2f1e0a2" } ], "sources": [ { "db": "VULMON", "id": "CVE-2020-7580" }, { "db": "JVNDB", "id": "JVNDB-2020-006496" }, { "db": "CNNVD", "id": "CNNVD-202006-636" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-428", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-185705" }, { "db": "JVNDB", "id": "JVNDB-2020-006496" }, { "db": "NVD", "id": "CVE-2020-7580" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.2, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04" }, { "trust": 1.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-7580" }, { "trust": 1.2, "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-04" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7580" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu97501786/" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/simatic-code-execution-via-windows-exe-extension-32489" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2020.2015/" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/428.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-161-04" } ], "sources": [ { "db": "VULHUB", "id": "VHN-185705" }, { "db": "VULMON", "id": "CVE-2020-7580" }, { "db": "JVNDB", "id": "JVNDB-2020-006496" }, { "db": "CNNVD", "id": "CNNVD-202006-636" }, { "db": "NVD", "id": "CVE-2020-7580" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-185705" }, { "db": "VULMON", "id": "CVE-2020-7580" }, { "db": "JVNDB", "id": "JVNDB-2020-006496" }, { "db": "CNNVD", "id": "CNNVD-202006-636" }, { "db": "NVD", "id": "CVE-2020-7580" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-10T00:00:00", "db": "VULHUB", "id": "VHN-185705" }, { "date": "2020-06-10T00:00:00", "db": "VULMON", "id": "CVE-2020-7580" }, { "date": "2020-07-09T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006496" }, { "date": "2020-06-09T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-636" }, { "date": "2020-06-10T17:15:12.347000", "db": "NVD", "id": "CVE-2020-7580" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-12-13T00:00:00", "db": "VULHUB", "id": "VHN-185705" }, { "date": "2022-04-12T00:00:00", "db": "VULMON", "id": "CVE-2020-7580" }, { "date": "2020-07-09T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006496" }, { "date": "2022-12-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-636" }, { "date": "2024-11-21T05:37:24.840000", "db": "NVD", "id": "CVE-2020-7580" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-636" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural SIMATIC Vulnerabilities in unquoted search paths or elements in products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006496" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "code problem", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-636" } ], "trust": 0.6 } }
var-201703-0642
Vulnerability from variot
Siemens SINUMERIK Integrate Operate Clients between 2.0.3.00.016 (including) and 2.0.6 (excluding) and between 3.0.4.00.032 (including) and 3.0.6 (excluding) contain a vulnerability that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack. Siemens SINUMERIK Integrate Operate Clients is a standard human interface system client for SINUMERIK digital control from Siemens AG. There is a middleman security bypass vulnerability in Siemens SINUMERIK Integrate Operate Clients. Multiple Siemens Products are prone to a security-bypass vulnerability. Successfully exploiting this issue may allow attackers to bypass certain security restrictions and perform unauthorized actions by conducting a man-in-the-middle attack. This may lead to other attacks
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201703-0642", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "sinumerik integrate operate client", "scope": "eq", "trust": 2.5, "vendor": "siemens", "version": "3.0.4.00.032" }, { "model": "sinumerik integrate operate client", "scope": "eq", "trust": 2.5, "vendor": "siemens", "version": "2.0.3.00.016" }, { "model": "sinumerik operate", "scope": "eq", "trust": 2.2, "vendor": "siemens", "version": "4.7" }, { "model": "sinumerik operate", "scope": "eq", "trust": 2.2, "vendor": "siemens", "version": "4.5" }, { "model": "sinumerik integrate access mymachine\\/ethernet", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": null }, { "model": "sinumerik integrate access mymachine/ethernet", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "0" }, { "model": "sinumerik integrate access mymachine/ethernet", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinumerik integrate operate client", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinumerik operate", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinumerik operate sp2 hotfix", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "4.71" }, { "model": "sinumerik operate sp6", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "4.5" }, { "model": "sinumerik operate sp2 hotfix", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v4.71" }, { "model": "sinumerik operate", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v4.7" }, { "model": "sinumerik operate sp6", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v4.5" }, { "model": "sinumerik operate", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v4.5" }, { "model": "sinumerik operate sp4", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "v4.7" }, { "model": "sinumerik operate sp6 hotfix", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "v4.58" }, { "model": "sinumerik integrate operate client", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "3.0.6" }, { "model": "sinumerik integrate operate client", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "2.0.6" }, { "model": "sinumerik integrate access mymachine/ethernet", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "v4.1.0.5" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinumerik integrate access mymachine ethernet", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinumerik integrate operate client", "version": "2.0.3.00.016" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinumerik integrate operate client", "version": "3.0.4.00.032" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinumerik operate", "version": "4.5" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinumerik operate", "version": "4.7" } ], "sources": [ { "db": "IVD", "id": "9505679d-5baf-4fd4-a0f0-a9be3ad1094b" }, { "db": "CNVD", "id": "CNVD-2017-02400" }, { "db": "BID", "id": "96519" }, { "db": "JVNDB", "id": "JVNDB-2017-002282" }, { "db": "CNNVD", "id": "CNNVD-201703-029" }, { "db": "NVD", "id": "CVE-2017-2685" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:siemens:sinumerik_integrate_access_mymachine%2Fethernet", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:sinumerik_integrate_operate_client", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:sinumerik_operate", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-002282" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "The vendor reported this issue.", "sources": [ { "db": "BID", "id": "96519" } ], "trust": 0.3 }, "cve": "CVE-2017-2685", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "CVE-2017-2685", "impactScore": 4.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N", "version": "2.0" }, { "accessComplexity": "HIGH", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 7.1, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 4.9, "id": "CNVD-2017-02400", "impactScore": 9.2, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:H/Au:N/C:C/I:C/A:N", "version": "2.0" }, { "accessComplexity": "HIGH", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "NONE", "baseScore": 7.1, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 4.9, "id": "9505679d-5baf-4fd4-a0f0-a9be3ad1094b", "impactScore": 9.2, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:H/Au:N/C:C/I:C/A:N", "version": "2.9 [IVD]" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "NONE", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "VHN-110888", "impactScore": 4.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "HIGH", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 7.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.2, "id": "CVE-2017-2685", "impactScore": 5.2, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2017-2685", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2017-2685", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2017-02400", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201703-029", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "9505679d-5baf-4fd4-a0f0-a9be3ad1094b", "trust": 0.2, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-110888", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "IVD", "id": "9505679d-5baf-4fd4-a0f0-a9be3ad1094b" }, { "db": "CNVD", "id": "CNVD-2017-02400" }, { "db": "VULHUB", "id": "VHN-110888" }, { "db": "JVNDB", "id": "JVNDB-2017-002282" }, { "db": "CNNVD", "id": "CNNVD-201703-029" }, { "db": "NVD", "id": "CVE-2017-2685" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens SINUMERIK Integrate Operate Clients between 2.0.3.00.016 (including) and 2.0.6 (excluding) and between 3.0.4.00.032 (including) and 3.0.6 (excluding) contain a vulnerability that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack. Siemens SINUMERIK Integrate Operate Clients is a standard human interface system client for SINUMERIK digital control from Siemens AG. There is a middleman security bypass vulnerability in Siemens SINUMERIK Integrate Operate Clients. Multiple Siemens Products are prone to a security-bypass vulnerability. \nSuccessfully exploiting this issue may allow attackers to bypass certain security restrictions and perform unauthorized actions by conducting a man-in-the-middle attack. This may lead to other attacks", "sources": [ { "db": "NVD", "id": "CVE-2017-2685" }, { "db": "JVNDB", "id": "JVNDB-2017-002282" }, { "db": "CNVD", "id": "CNVD-2017-02400" }, { "db": "BID", "id": "96519" }, { "db": "IVD", "id": "9505679d-5baf-4fd4-a0f0-a9be3ad1094b" }, { "db": "VULHUB", "id": "VHN-110888" } ], "trust": 2.7 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2017-2685", "trust": 3.6 }, { "db": "BID", "id": "96519", "trust": 2.6 }, { "db": "SIEMENS", "id": "SSA-934525", "trust": 2.6 }, { "db": "CNNVD", "id": "CNNVD-201703-029", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2017-02400", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2017-002282", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-17-061-03", "trust": 0.3 }, { "db": "IVD", "id": "9505679D-5BAF-4FD4-A0F0-A9BE3AD1094B", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-110888", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "9505679d-5baf-4fd4-a0f0-a9be3ad1094b" }, { "db": "CNVD", "id": "CNVD-2017-02400" }, { "db": "VULHUB", "id": "VHN-110888" }, { "db": "BID", "id": "96519" }, { "db": "JVNDB", "id": "JVNDB-2017-002282" }, { "db": "CNNVD", "id": "CNNVD-201703-029" }, { "db": "NVD", "id": "CVE-2017-2685" } ] }, "id": "VAR-201703-0642", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "9505679d-5baf-4fd4-a0f0-a9be3ad1094b" }, { "db": "CNVD", "id": "CNVD-2017-02400" }, { "db": "VULHUB", "id": "VHN-110888" } ], "trust": 1.5200000080000002 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "9505679d-5baf-4fd4-a0f0-a9be3ad1094b" }, { "db": "CNVD", "id": "CNVD-2017-02400" } ] }, "last_update_date": "2024-11-23T22:30:50.015000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-934525", "trust": 0.8, "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-934525.pdf" }, { "title": "Siemens SINUMERIK Integrate Operate Clients patch for security breaches", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/89987" }, { "title": "Siemens SINUMERIK Integrate Operate Clients Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=68022" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2017-02400" }, { "db": "JVNDB", "id": "JVNDB-2017-002282" }, { "db": "CNNVD", "id": "CNNVD-201703-029" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-200", "trust": 1.9 }, { "problemtype": "CWE-693", "trust": 1.0 } ], "sources": [ { "db": "VULHUB", "id": "VHN-110888" }, { "db": "JVNDB", "id": "JVNDB-2017-002282" }, { "db": "NVD", "id": "CVE-2017-2685" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.6, "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-934525.pdf" }, { "trust": 2.3, "url": "http://www.securityfocus.com/bid/96519" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-2685" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2017-2685" }, { "trust": 0.8, "url": "https://blogs.gentoo.org/ago/2017/03/02/podofo-null-pointer-dereference-in-podofopdfcolorgraypdfcolorgray-pdfcolor-cpp/" }, { "trust": 0.6, "url": "https://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2017-2685" }, { "trust": 0.3, "url": "http://www.siemens.com/" }, { "trust": 0.3, "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-061-03" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2017-02400" }, { "db": "VULHUB", "id": "VHN-110888" }, { "db": "BID", "id": "96519" }, { "db": "JVNDB", "id": "JVNDB-2017-002282" }, { "db": "CNNVD", "id": "CNNVD-201703-029" }, { "db": "NVD", "id": "CVE-2017-2685" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "9505679d-5baf-4fd4-a0f0-a9be3ad1094b" }, { "db": "CNVD", "id": "CNVD-2017-02400" }, { "db": "VULHUB", "id": "VHN-110888" }, { "db": "BID", "id": "96519" }, { "db": "JVNDB", "id": "JVNDB-2017-002282" }, { "db": "CNNVD", "id": "CNNVD-201703-029" }, { "db": "NVD", "id": "CVE-2017-2685" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2017-03-05T00:00:00", "db": "IVD", "id": "9505679d-5baf-4fd4-a0f0-a9be3ad1094b" }, { "date": "2017-03-05T00:00:00", "db": "CNVD", "id": "CNVD-2017-02400" }, { "date": "2017-03-01T00:00:00", "db": "VULHUB", "id": "VHN-110888" }, { "date": "2017-03-01T00:00:00", "db": "BID", "id": "96519" }, { "date": "2017-04-07T00:00:00", "db": "JVNDB", "id": "JVNDB-2017-002282" }, { "date": "2017-03-02T00:00:00", "db": "CNNVD", "id": "CNNVD-201703-029" }, { "date": "2017-03-01T17:59:00.143000", "db": "NVD", "id": "CVE-2017-2685" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2017-03-05T00:00:00", "db": "CNVD", "id": "CNVD-2017-02400" }, { "date": "2019-10-09T00:00:00", "db": "VULHUB", "id": "VHN-110888" }, { "date": "2017-03-07T01:09:00", "db": "BID", "id": "96519" }, { "date": "2017-04-07T00:00:00", "db": "JVNDB", "id": "JVNDB-2017-002282" }, { "date": "2019-10-17T00:00:00", "db": "CNNVD", "id": "CNNVD-201703-029" }, { "date": "2024-11-21T03:23:58.560000", "db": "NVD", "id": "CVE-2017-2685" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201703-029" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens SINUMERIK Integrate Operate Client In TLS Vulnerability to read session data", "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-002282" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "information disclosure", "sources": [ { "db": "CNNVD", "id": "CNNVD-201703-029" } ], "trust": 0.6 } }
var-202107-0958
Vulnerability from variot
A vulnerability has been identified in SINUMERIK Analyse MyCondition (All versions), SINUMERIK Analyze MyPerformance (All versions), SINUMERIK Analyze MyPerformance /OEE-Monitor (All versions), SINUMERIK Analyze MyPerformance /OEE-Tuning (All versions), SINUMERIK Integrate Client 02 (All versions >= V02.00.12 < 02.00.18), SINUMERIK Integrate Client 03 (All versions >= V03.00.12 < 03.00.18), SINUMERIK Integrate Client 04 (V04.00.02 and all versions >= V04.00.15 < 04.00.18), SINUMERIK Integrate for Production 4.1 (All versions < V4.1 SP10 HF3), SINUMERIK Integrate for Production 5.1 (V5.1), SINUMERIK Manage MyMachines (All versions), SINUMERIK Manage MyMachines /Remote (All versions), SINUMERIK Manage MyMachines /Spindel Monitor (All versions), SINUMERIK Manage MyPrograms (All versions), SINUMERIK Manage MyResources /Programs (All versions), SINUMERIK Manage MyResources /Tools (All versions), SINUMERIK Manage MyTools (All versions), SINUMERIK Operate V4.8 (All versions < V4.8 SP8), SINUMERIK Operate V4.93 (All versions < V4.93 HF7), SINUMERIK Operate V4.94 (All versions < V4.94 HF5), SINUMERIK Optimize MyProgramming /NX-Cam Editor (All versions). Due to an error in a third-party dependency the ssl flags used for setting up a TLS connection to a server are overwitten with wrong settings. This results in a missing validation of the server certificate and thus in a possible TLS MITM szenario. Multiple Siemens products contain certificate validation vulnerabilities.Information may be obtained and information may be tampered with. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202107-0958", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "sinumerik integrate for production", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "5.1" }, { "model": "sinumerik integrate client", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "4.00.15" }, { "model": "sinumerik manage mymachines", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "sinumerik operate", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.93" }, { "model": "sinumerik operate", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "sinumerik manage myresources", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "sinumerik analyze myperformance", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "sinumerik analyse mycondition", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "sinumerik integrate client", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "3.00.12" }, { "model": "sinumerik operate", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.94" }, { "model": "sinumerik optimize myprogramming", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "sinumerik integrate client", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "2.00.12" }, { "model": "sinumerik operate", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "sinumerik manage myprograms", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "sinumerik integrate client", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.00.18" }, { "model": "sinumerik manage mytools", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "sinumerik integrate client", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.00.18" }, { "model": "sinumerik integrate for production", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "4.1" }, { "model": "sinumerik integrate client", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.00.18" }, { "model": "sinumerik analyze myperformance", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinumerik integrate client", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinumerik operate", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinumerik manage myprograms", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinumerik integrate for production", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinumerik manage myresources", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinumerik manage mytools", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinumerik analyse mycondition", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinumerik manage mymachines", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-012066" }, { "db": "NVD", "id": "CVE-2021-31892" } ] }, "cve": "CVE-2021-31892", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "CVE-2021-31892", "impactScore": 4.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "HIGH", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 7.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.2, "id": "CVE-2021-31892", "impactScore": 5.2, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, { "attackComplexity": "High", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 7.4, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-31892", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-31892", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2021-31892", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202107-936", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-012066" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-936" }, { "db": "NVD", "id": "CVE-2021-31892" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SINUMERIK Analyse MyCondition (All versions), SINUMERIK Analyze MyPerformance (All versions), SINUMERIK Analyze MyPerformance /OEE-Monitor (All versions), SINUMERIK Analyze MyPerformance /OEE-Tuning (All versions), SINUMERIK Integrate Client 02 (All versions \u003e= V02.00.12 \u003c 02.00.18), SINUMERIK Integrate Client 03 (All versions \u003e= V03.00.12 \u003c 03.00.18), SINUMERIK Integrate Client 04 (V04.00.02 and all versions \u003e= V04.00.15 \u003c 04.00.18), SINUMERIK Integrate for Production 4.1 (All versions \u003c V4.1 SP10 HF3), SINUMERIK Integrate for Production 5.1 (V5.1), SINUMERIK Manage MyMachines (All versions), SINUMERIK Manage MyMachines /Remote (All versions), SINUMERIK Manage MyMachines /Spindel Monitor (All versions), SINUMERIK Manage MyPrograms (All versions), SINUMERIK Manage MyResources /Programs (All versions), SINUMERIK Manage MyResources /Tools (All versions), SINUMERIK Manage MyTools (All versions), SINUMERIK Operate V4.8 (All versions \u003c V4.8 SP8), SINUMERIK Operate V4.93 (All versions \u003c V4.93 HF7), SINUMERIK Operate V4.94 (All versions \u003c V4.94 HF5), SINUMERIK Optimize MyProgramming /NX-Cam Editor (All versions). Due to an error in a third-party dependency the ssl flags used for setting up a TLS connection to a server are overwitten with wrong settings. This results in a missing validation of the server certificate and thus in a possible TLS MITM szenario. Multiple Siemens products contain certificate validation vulnerabilities.Information may be obtained and information may be tampered with. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements", "sources": [ { "db": "NVD", "id": "CVE-2021-31892" }, { "db": "JVNDB", "id": "JVNDB-2021-012066" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULMON", "id": "CVE-2021-31892" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-31892", "trust": 3.3 }, { "db": "ICS CERT", "id": "ICSA-21-194-04", "trust": 2.4 }, { "db": "SIEMENS", "id": "SSA-729965", "trust": 1.7 }, { "db": "JVNDB", "id": "JVNDB-2021-012066", "trust": 0.8 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2021.2400", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021071419", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202107-936", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-31892", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-31892" }, { "db": "JVNDB", "id": "JVNDB-2021-012066" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-936" }, { "db": "NVD", "id": "CVE-2021-31892" } ] }, "id": "VAR-202107-0958", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.33333334 }, "last_update_date": "2024-08-14T12:06:50.772000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-729965", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-729965.pdf" }, { "title": "Siemens SINUMERIK Repair measures for trust management problem vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=156629" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=5c67d9cd3bf80eef1b0e658801ea5c7b" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-31892" }, { "db": "JVNDB", "id": "JVNDB-2021-012066" }, { "db": "CNNVD", "id": "CNNVD-202107-936" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-295", "trust": 1.0 }, { "problemtype": "Illegal certificate verification (CWE-295) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-012066" }, { "db": "NVD", "id": "CVE-2021-31892" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-729965.pdf" }, { "trust": 1.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-04" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-31892" }, { "trust": 0.8, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-194-04" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021071419" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2021.2400" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/295.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://cert-portal.siemens.com/productcert/txt/ssa-729965.txt" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-31892" }, { "db": "JVNDB", "id": "JVNDB-2021-012066" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-936" }, { "db": "NVD", "id": "CVE-2021-31892" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-31892" }, { "db": "JVNDB", "id": "JVNDB-2021-012066" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-936" }, { "db": "NVD", "id": "CVE-2021-31892" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-07-13T00:00:00", "db": "VULMON", "id": "CVE-2021-31892" }, { "date": "2022-08-23T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-012066" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-07-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202107-936" }, { "date": "2021-07-13T11:15:09.453000", "db": "NVD", "id": "CVE-2021-31892" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-07-13T00:00:00", "db": "VULMON", "id": "CVE-2021-31892" }, { "date": "2022-08-23T05:18:00", "db": "JVNDB", "id": "JVNDB-2021-012066" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-08-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202107-936" }, { "date": "2021-08-09T16:26:16.037000", "db": "NVD", "id": "CVE-2021-31892" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202107-936" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certificate validation vulnerability in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-012066" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-975" } ], "trust": 0.6 } }