All the vulnerabilites related to Siemens - SINAMICS SH150
var-202105-0690
Vulnerability from variot
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution. Several Siemens products are vulnerable to access to memory areas after buffer termination.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Siemens SmartVNC is an industrial control equipment of Siemens (Siemens), Germany.
Siemens SmartVNC has an out-of-bounds memory access vulnerability. Remote attackers can use the vulnerability to submit special requests, which can crash the application or execute arbitrary code in the context of the application. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202105-0690", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics sl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinamics gm150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic wincc runtime advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinamics sm150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinamics sm150i", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic wincc runtime advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gh150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics sm120", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics sh150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics sh150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sl150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sm120", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sm150i", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi comfort outdoor panels 7\"", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics gh150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sm150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics gl150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics gm150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "smartvnc", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37750" }, { "db": "JVNDB", "id": "JVNDB-2021-006949" }, { "db": "NVD", "id": "CVE-2021-27384" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-548" } ], "trust": 0.6 }, "cve": "CVE-2021-27384", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2021-27384", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CNVD-2021-37750", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-27384", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-27384", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-27384", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2021-27384", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2021-37750", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202105-548", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-27384", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37750" }, { "db": "VULMON", "id": "CVE-2021-27384" }, { "db": "JVNDB", "id": "JVNDB-2021-006949" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-548" }, { "db": "NVD", "id": "CVE-2021-27384" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution. Several Siemens products are vulnerable to access to memory areas after buffer termination.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Siemens SmartVNC is an industrial control equipment of Siemens (Siemens), Germany. \n\r\n\r\nSiemens SmartVNC has an out-of-bounds memory access vulnerability. Remote attackers can use the vulnerability to submit special requests, which can crash the application or execute arbitrary code in the context of the application. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements", "sources": [ { "db": "NVD", "id": "CVE-2021-27384" }, { "db": "JVNDB", "id": "JVNDB-2021-006949" }, { "db": "CNVD", "id": "CNVD-2021-37750" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULMON", "id": "CVE-2021-27384" } ], "trust": 2.79 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-27384", "trust": 3.9 }, { "db": "ICS CERT", "id": "ICSA-21-131-11", "trust": 2.5 }, { "db": "SIEMENS", "id": "SSA-286838", "trust": 1.7 }, { "db": "SIEMENS", "id": "SSA-538778", "trust": 1.6 }, { "db": "ICS CERT", "id": "ICSA-21-131-12", "trust": 1.2 }, { "db": "JVN", "id": "JVNVU91051134", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-006949", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-37750", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021051206", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-21-131-04", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202105-548", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-27384", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37750" }, { "db": "VULMON", "id": "CVE-2021-27384" }, { "db": "JVNDB", "id": "JVNDB-2021-006949" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-548" }, { "db": "NVD", "id": "CVE-2021-27384" } ] }, "id": "VAR-202105-0690", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-37750" } ], "trust": 1.205898611111111 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37750" } ] }, "last_update_date": "2024-08-14T13:12:43.619000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-286838 Siemens\u00a0Security\u00a0Advisory", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "title": "Patch for Siemens SmartVNC memory out-of-bounds access vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/268666" }, { "title": "Siemens SmartVNC Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=155975" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=43c9c77785b8d29daef02185f41ca476" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=9465a8ef1f8c1b0042244cb02cfe271e" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37750" }, { "db": "VULMON", "id": "CVE-2021-27384" }, { "db": "JVNDB", "id": "JVNDB-2021-006949" }, { "db": "CNNVD", "id": "CNNVD-202105-548" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-788", "trust": 1.0 }, { "problemtype": "Access to memory area after buffer termination (CWE-788) [ Other ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006949" }, { "db": "NVD", "id": "CVE-2021-27384" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" }, { "trust": 1.6, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "trust": 1.6, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "trust": 1.2, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu91051134/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-27384" }, { "trust": 0.8, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-131-11" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021051206" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/smartvnc-multiple-vulnerabilities-35360" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/788.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://cert-portal.siemens.com/productcert/txt/ssa-286838.txt" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37750" }, { "db": "VULMON", "id": "CVE-2021-27384" }, { "db": "JVNDB", "id": "JVNDB-2021-006949" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-548" }, { "db": "NVD", "id": "CVE-2021-27384" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-37750" }, { "db": "VULMON", "id": "CVE-2021-27384" }, { "db": "JVNDB", "id": "JVNDB-2021-006949" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-548" }, { "db": "NVD", "id": "CVE-2021-27384" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-05-28T00:00:00", "db": "CNVD", "id": "CNVD-2021-37750" }, { "date": "2021-05-12T00:00:00", "db": "VULMON", "id": "CVE-2021-27384" }, { "date": "2022-01-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-006949" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-05-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-548" }, { "date": "2021-05-12T14:15:11.677000", "db": "NVD", "id": "CVE-2021-27384" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-05-28T00:00:00", "db": "CNVD", "id": "CNVD-2021-37750" }, { "date": "2021-05-21T00:00:00", "db": "VULMON", "id": "CVE-2021-27384" }, { "date": "2022-01-26T07:30:00", "db": "JVNDB", "id": "JVNDB-2021-006949" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-10-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-548" }, { "date": "2021-12-16T18:26:10.080000", "db": "NVD", "id": "CVE-2021-27384" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-548" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Vulnerabilities in access to memory areas after buffer termination in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006949" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-548" } ], "trust": 1.2 } }
var-202102-0161
Vulnerability from variot
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046). This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Comfort Panel. Authentication is not required to exploit this vulnerability.The specific flaw exists within the telnet service, which listens on TCP port 22 by default. The issue results from the lack of authentication prior to allowing remote connections. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Siemens Simatic Hmi is a device of Germany's Siemens (Siemens) that provides human-computer interaction functions for industrial automation equipment
Show details on source website{ "affected_products": { "_id": null, "data": [ { "_id": null, "model": "simatic hmi ktp mobile panels", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16.0" }, { "_id": null, "model": "sinamics gl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "_id": null, "model": "simatic hmi comfort panels", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16.0" }, { "_id": null, "model": "simatic hmi ktp mobile panels", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16.0" }, { "_id": null, "model": "sinamics sl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "_id": null, "model": "sinamics sm150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "_id": null, "model": "sinamics sh150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "_id": null, "model": "sinamics sm150i", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "_id": null, "model": "sinamics sm120", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "_id": null, "model": "sinamics gh150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "_id": null, "model": "sinamics gm150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "_id": null, "model": "simatic hmi comfort panels", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16.0" }, { "_id": null, "model": "simatic hmi comfort panels", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "_id": null, "model": "simatic hmi ktp mobile panels", "scope": "lt", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": "v16 update 3a earlier versions" }, { "_id": null, "model": "comfort panel", "scope": null, "trust": 0.7, "vendor": "siemens", "version": null }, { "_id": null, "model": "simatic hmi", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-129" }, { "db": "CNVD", "id": "CNVD-2021-07537" }, { "db": "JVNDB", "id": "JVNDB-2021-001015" }, { "db": "NVD", "id": "CVE-2020-15798" } ] }, "credits": { "_id": null, "data": "Ta-Lun Yen of TXOne IoT/ICS Security Research Labs (Trend Micro)", "sources": [ { "db": "ZDI", "id": "ZDI-21-129" } ], "trust": 0.7 }, "cve": "CVE-2020-15798", "cvss": { "_id": null, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.6, "id": "CVE-2020-15798", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.1, "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "exploitabilityScore": 8.6, "id": "CNVD-2021-07537", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2020-15798", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "High", "attackVector": "Network", "author": "IPA", "availabilityImpact": "High", "baseScore": 8.1, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-001015", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "ZDI", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2020-15798", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 0.7, "userInteraction": "NONE", "vectorString": "AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-15798", "trust": 1.0, "value": "CRITICAL" }, { "author": "IPA", "id": "JVNDB-2021-001015", "trust": 0.8, "value": "High" }, { "author": "ZDI", "id": "CVE-2020-15798", "trust": 0.7, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2021-07537", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202101-2499", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2020-15798", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-129" }, { "db": "CNVD", "id": "CNVD-2021-07537" }, { "db": "VULMON", "id": "CVE-2020-15798" }, { "db": "JVNDB", "id": "JVNDB-2021-001015" }, { "db": "CNNVD", "id": "CNNVD-202101-2499" }, { "db": "NVD", "id": "CVE-2020-15798" } ] }, "description": { "_id": null, "data": "A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions \u003c V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions \u003c V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046). This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Comfort Panel. Authentication is not required to exploit this vulnerability.The specific flaw exists within the telnet service, which listens on TCP port 22 by default. The issue results from the lack of authentication prior to allowing remote connections. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Siemens Simatic Hmi is a device of Germany\u0027s Siemens (Siemens) that provides human-computer interaction functions for industrial automation equipment", "sources": [ { "db": "NVD", "id": "CVE-2020-15798" }, { "db": "JVNDB", "id": "JVNDB-2021-001015" }, { "db": "ZDI", "id": "ZDI-21-129" }, { "db": "CNVD", "id": "CNVD-2021-07537" }, { "db": "VULMON", "id": "CVE-2020-15798" } ], "trust": 2.88 }, "external_ids": { "_id": null, "data": [ { "db": "NVD", "id": "CVE-2020-15798", "trust": 3.8 }, { "db": "ICS CERT", "id": "ICSA-21-033-02", "trust": 2.5 }, { "db": "SIEMENS", "id": "SSA-520004", "trust": 1.7 }, { "db": "SIEMENS", "id": "SSA-752103", "trust": 1.7 }, { "db": "ZDI", "id": "ZDI-21-129", "trust": 0.8 }, { "db": "JVN", "id": "JVNVU92618342", "trust": 0.8 }, { "db": "JVN", "id": "JVNVU91051134", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-001015", "trust": 0.8 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-12046", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2021-07537", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-21-131-13", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2021.0384", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202101-2499", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2020-15798", "trust": 0.1 } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-129" }, { "db": "CNVD", "id": "CNVD-2021-07537" }, { "db": "VULMON", "id": "CVE-2020-15798" }, { "db": "JVNDB", "id": "JVNDB-2021-001015" }, { "db": "CNNVD", "id": "CNNVD-202101-2499" }, { "db": "NVD", "id": "CVE-2020-15798" } ] }, "id": "VAR-202102-0161", "iot": { "_id": null, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-07537" } ], "trust": 1.17291723125 }, "iot_taxonomy": { "_id": null, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-07537" } ] }, "last_update_date": "2024-11-23T19:29:19.148000Z", "patch": { "_id": null, "data": [ { "title": "SSA-520004", "trust": 0.8, "url": "https://support.industry.siemens.com/cs/document/109746530/image-downloads-for-hmi-operator-panels?dti=0\u0026lc=en-WW" }, { "title": "Siemens has issued an update to correct this vulnerability.", "trust": 0.7, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02" }, { "title": "Patch for Siemens Simatic Hmi authorization issue vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/246031" }, { "title": "Siemens Simatic Hmi Remediation measures for authorization problem vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=140096" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=727a7bb82c467c1176e726c944e1c560" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=a4e80f78fa87968e8881f762b328bbfa" }, { "title": "", "trust": 0.1, "url": "https://github.com/Live-Hack-CVE/CVE-2020-15798 " } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-129" }, { "db": "CNVD", "id": "CNVD-2021-07537" }, { "db": "VULMON", "id": "CVE-2020-15798" }, { "db": "JVNDB", "id": "JVNDB-2021-001015" }, { "db": "CNNVD", "id": "CNNVD-202101-2499" } ] }, "problemtype_data": { "_id": null, "data": [ { "problemtype": "CWE-306", "trust": 1.0 }, { "problemtype": "Lack of authentication for important features (CWE-306) [IPA Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-001015" }, { "db": "NVD", "id": "CVE-2020-15798" } ] }, "references": { "_id": null, "data": [ { "trust": 3.8, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf" }, { "trust": 1.2, "url": "https://vigilance.fr/vulnerability/simatic-hmi-code-execution-via-unauthenticated-telnet-34430" }, { "trust": 0.8, "url": "http://jvn.jp/cert/jvnvu92618342" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu91051134/index.html" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2021.0384/" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-13" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/306.html" }, { "trust": 0.1, "url": "https://github.com/live-hack-cve/cve-2020-15798" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://www.zerodayinitiative.com/advisories/zdi-21-129/" } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-129" }, { "db": "CNVD", "id": "CNVD-2021-07537" }, { "db": "VULMON", "id": "CVE-2020-15798" }, { "db": "JVNDB", "id": "JVNDB-2021-001015" }, { "db": "CNNVD", "id": "CNNVD-202101-2499" }, { "db": "NVD", "id": "CVE-2020-15798" } ] }, "sources": { "_id": null, "data": [ { "db": "ZDI", "id": "ZDI-21-129", "ident": null }, { "db": "CNVD", "id": "CNVD-2021-07537", "ident": null }, { "db": "VULMON", "id": "CVE-2020-15798", "ident": null }, { "db": "JVNDB", "id": "JVNDB-2021-001015", "ident": null }, { "db": "CNNVD", "id": "CNNVD-202101-2499", "ident": null }, { "db": "NVD", "id": "CVE-2020-15798", "ident": null } ] }, "sources_release_date": { "_id": null, "data": [ { "date": "2021-02-04T00:00:00", "db": "ZDI", "id": "ZDI-21-129", "ident": null }, { "date": "2021-01-31T00:00:00", "db": "CNVD", "id": "CNVD-2021-07537", "ident": null }, { "date": "2021-02-09T00:00:00", "db": "VULMON", "id": "CVE-2020-15798", "ident": null }, { "date": "2021-02-01T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-001015", "ident": null }, { "date": "2021-01-28T00:00:00", "db": "CNNVD", "id": "CNNVD-202101-2499", "ident": null }, { "date": "2021-02-09T17:15:13.437000", "db": "NVD", "id": "CVE-2020-15798", "ident": null } ] }, "sources_update_date": { "_id": null, "data": [ { "date": "2021-02-04T00:00:00", "db": "ZDI", "id": "ZDI-21-129", "ident": null }, { "date": "2021-02-03T00:00:00", "db": "CNVD", "id": "CNVD-2021-07537", "ident": null }, { "date": "2022-10-19T00:00:00", "db": "VULMON", "id": "CVE-2020-15798", "ident": null }, { "date": "2021-05-19T07:05:00", "db": "JVNDB", "id": "JVNDB-2021-001015", "ident": null }, { "date": "2021-08-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202101-2499", "ident": null }, { "date": "2024-11-21T05:06:12.120000", "db": "NVD", "id": "CVE-2020-15798", "ident": null } ] }, "threat_type": { "_id": null, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202101-2499" } ], "trust": 0.6 }, "title": { "_id": null, "data": "Siemens\u00a0 Made \u00a0HMI\u00a0 Lack of authentication vulnerability for product critical features", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-001015" } ], "trust": 0.8 }, "type": { "_id": null, "data": "access control error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202101-2499" } ], "trust": 0.6 } }
var-202105-0692
Vulnerability from variot
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition. Several Siemens products are vulnerable to a lack of memory release after expiration.Denial of service (DoS) It may be put into a state. Siemens SmartVNC is an industrial control equipment of Germany's Siemens (Siemens) company. Provides an access to the smartserver function in the HMI. Attackers can use the vulnerability to cause a denial of service. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202105-0692", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics sl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinamics gm150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic wincc runtime advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinamics sm150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinamics sm150i", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic wincc runtime advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gh150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics sm120", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics sh150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics sh150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sl150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sm120", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sm150i", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi comfort outdoor panels 7\"", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics gh150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sm150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics gl150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics gm150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sl150", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics sm150", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics sm150i", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics gh150", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics gl150 (with option", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x30)" }, { "model": "sinamics gm150 (with option", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x30)" }, { "model": "sinamics sh150", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics sm120", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-67537" }, { "db": "JVNDB", "id": "JVNDB-2021-006951" }, { "db": "NVD", "id": "CVE-2021-27386" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-477" } ], "trust": 0.6 }, "cve": "CVE-2021-27386", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2021-27386", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2021-67537", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2021-27386", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-27386", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-27386", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2021-27386", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-67537", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202105-477", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-27386", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-67537" }, { "db": "VULMON", "id": "CVE-2021-27386" }, { "db": "JVNDB", "id": "JVNDB-2021-006951" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-477" }, { "db": "NVD", "id": "CVE-2021-27386" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition. Several Siemens products are vulnerable to a lack of memory release after expiration.Denial of service (DoS) It may be put into a state. Siemens SmartVNC is an industrial control equipment of Germany\u0027s Siemens (Siemens) company. Provides an access to the smartserver function in the HMI. Attackers can use the vulnerability to cause a denial of service. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements", "sources": [ { "db": "NVD", "id": "CVE-2021-27386" }, { "db": "JVNDB", "id": "JVNDB-2021-006951" }, { "db": "CNVD", "id": "CNVD-2021-67537" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULMON", "id": "CVE-2021-27386" } ], "trust": 2.79 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-27386", "trust": 3.9 }, { "db": "ICS CERT", "id": "ICSA-21-131-12", "trust": 2.4 }, { "db": "SIEMENS", "id": "SSA-286838", "trust": 2.3 }, { "db": "SIEMENS", "id": "SSA-538778", "trust": 1.7 }, { "db": "JVN", "id": "JVNVU91051134", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-006951", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-67537", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021051206", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-21-131-04", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202105-477", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-27386", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-67537" }, { "db": "VULMON", "id": "CVE-2021-27386" }, { "db": "JVNDB", "id": "JVNDB-2021-006951" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-477" }, { "db": "NVD", "id": "CVE-2021-27386" } ] }, "id": "VAR-202105-0692", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-67537" } ], "trust": 1.24530875 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-67537" } ] }, "last_update_date": "2024-08-14T12:18:07.716000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-286838 Siemens\u00a0Security\u00a0Advisory", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "title": "Patch for Siemens SmartVNC heap allocation leak vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/285861" }, { "title": "Siemens SmartVNC Buffer error vulnerability fix", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=151556" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=43c9c77785b8d29daef02185f41ca476" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=9465a8ef1f8c1b0042244cb02cfe271e" }, { "title": "CVE-2021-27386", "trust": 0.1, "url": "https://github.com/JamesGeee/CVE-2021-27386 " } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-67537" }, { "db": "VULMON", "id": "CVE-2021-27386" }, { "db": "JVNDB", "id": "JVNDB-2021-006951" }, { "db": "CNNVD", "id": "CNNVD-202105-477" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-401", "trust": 1.0 }, { "problemtype": "Lack of free memory after expiration (CWE-401) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006951" }, { "db": "NVD", "id": "CVE-2021-27386" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "trust": 2.2, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu91051134/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-27386" }, { "trust": 0.8, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-131-12" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021051206" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/smartvnc-multiple-vulnerabilities-35360" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/401.html" }, { "trust": 0.1, "url": "https://github.com/jamesgeee/cve-2021-27386" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://cert-portal.siemens.com/productcert/txt/ssa-286838.txt" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-67537" }, { "db": "VULMON", "id": "CVE-2021-27386" }, { "db": "JVNDB", "id": "JVNDB-2021-006951" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-477" }, { "db": "NVD", "id": "CVE-2021-27386" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-67537" }, { "db": "VULMON", "id": "CVE-2021-27386" }, { "db": "JVNDB", "id": "JVNDB-2021-006951" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-477" }, { "db": "NVD", "id": "CVE-2021-27386" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-09-02T00:00:00", "db": "CNVD", "id": "CNVD-2021-67537" }, { "date": "2021-05-12T00:00:00", "db": "VULMON", "id": "CVE-2021-27386" }, { "date": "2022-01-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-006951" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-05-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-477" }, { "date": "2021-05-12T14:15:11.767000", "db": "NVD", "id": "CVE-2021-27386" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "CNVD", "id": "CNVD-2021-67537" }, { "date": "2021-05-21T00:00:00", "db": "VULMON", "id": "CVE-2021-27386" }, { "date": "2022-01-26T07:30:00", "db": "JVNDB", "id": "JVNDB-2021-006951" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-10-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-477" }, { "date": "2022-01-04T17:22:06.867000", "db": "NVD", "id": "CVE-2021-27386" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-477" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Vulnerability regarding lack of memory release after expiration in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006951" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-975" } ], "trust": 0.6 } }
var-202105-0689
Vulnerability from variot
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition. Multiple Siemens products are vulnerable to resource allocation without restrictions or throttling.Denial of service (DoS) It may be put into a state. Siemens SmartVNC is an industrial control equipment of Germany's Siemens (Siemens) company. Provides a function to access the smartserver in the HMI.
SmartVNC has a buffer overflow vulnerability. No detailed vulnerability details are currently provided. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202105-0689", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics sl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinamics gm150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic wincc runtime advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinamics sm150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinamics sm150i", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic wincc runtime advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gh150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics sm120", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics sh150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics sh150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sl150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sm120", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sm150i", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi comfort outdoor panels 7\"", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics gh150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sm150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics gl150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics gm150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "smartvnc", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37595" }, { "db": "JVNDB", "id": "JVNDB-2021-006948" }, { "db": "NVD", "id": "CVE-2021-27383" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-550" } ], "trust": 0.6 }, "cve": "CVE-2021-27383", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2021-27383", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2021-37595", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2021-27383", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-27383", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-27383", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2021-27383", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-37595", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202105-550", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-27383", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37595" }, { "db": "VULMON", "id": "CVE-2021-27383" }, { "db": "JVNDB", "id": "JVNDB-2021-006948" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-550" }, { "db": "NVD", "id": "CVE-2021-27383" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition. Multiple Siemens products are vulnerable to resource allocation without restrictions or throttling.Denial of service (DoS) It may be put into a state. Siemens SmartVNC is an industrial control equipment of Germany\u0027s Siemens (Siemens) company. Provides a function to access the smartserver in the HMI. \n\r\n\r\nSmartVNC has a buffer overflow vulnerability. No detailed vulnerability details are currently provided. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements", "sources": [ { "db": "NVD", "id": "CVE-2021-27383" }, { "db": "JVNDB", "id": "JVNDB-2021-006948" }, { "db": "CNVD", "id": "CNVD-2021-37595" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULMON", "id": "CVE-2021-27383" } ], "trust": 2.79 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-27383", "trust": 3.9 }, { "db": "ICS CERT", "id": "ICSA-21-131-12", "trust": 2.5 }, { "db": "SIEMENS", "id": "SSA-286838", "trust": 1.7 }, { "db": "SIEMENS", "id": "SSA-538778", "trust": 1.7 }, { "db": "JVN", "id": "JVNVU91051134", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-006948", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-37595", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021051206", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-21-131-04", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202105-550", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-27383", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37595" }, { "db": "VULMON", "id": "CVE-2021-27383" }, { "db": "JVNDB", "id": "JVNDB-2021-006948" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-550" }, { "db": "NVD", "id": "CVE-2021-27383" } ] }, "id": "VAR-202105-0689", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-37595" } ], "trust": 1.205898611111111 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37595" } ] }, "last_update_date": "2024-08-14T12:12:16.353000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-286838 Siemens\u00a0Security\u00a0Advisory", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "title": "Patch for Siemens SmartVNC buffer overflow vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/268266" }, { "title": "Siemens SmartVNC Buffer error vulnerability fix", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=151560" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=43c9c77785b8d29daef02185f41ca476" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=9465a8ef1f8c1b0042244cb02cfe271e" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37595" }, { "db": "VULMON", "id": "CVE-2021-27383" }, { "db": "JVNDB", "id": "JVNDB-2021-006948" }, { "db": "CNNVD", "id": "CNNVD-202105-550" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-770", "trust": 1.0 }, { "problemtype": "Allocation of resources without limits or throttling (CWE-770) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006948" }, { "db": "NVD", "id": "CVE-2021-27383" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-27383" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu91051134/" }, { "trust": 0.8, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-131-12" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021051206" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/smartvnc-multiple-vulnerabilities-35360" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/770.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://cert-portal.siemens.com/productcert/txt/ssa-286838.txt" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37595" }, { "db": "VULMON", "id": "CVE-2021-27383" }, { "db": "JVNDB", "id": "JVNDB-2021-006948" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-550" }, { "db": "NVD", "id": "CVE-2021-27383" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-37595" }, { "db": "VULMON", "id": "CVE-2021-27383" }, { "db": "JVNDB", "id": "JVNDB-2021-006948" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-550" }, { "db": "NVD", "id": "CVE-2021-27383" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-05-28T00:00:00", "db": "CNVD", "id": "CNVD-2021-37595" }, { "date": "2021-05-12T00:00:00", "db": "VULMON", "id": "CVE-2021-27383" }, { "date": "2022-01-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-006948" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-05-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-550" }, { "date": "2021-05-12T14:15:11.633000", "db": "NVD", "id": "CVE-2021-27383" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-09-07T00:00:00", "db": "CNVD", "id": "CNVD-2021-37595" }, { "date": "2021-12-16T00:00:00", "db": "VULMON", "id": "CVE-2021-27383" }, { "date": "2022-01-26T07:30:00", "db": "JVNDB", "id": "JVNDB-2021-006948" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-10-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-550" }, { "date": "2021-12-16T18:29:27.357000", "db": "NVD", "id": "CVE-2021-27383" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-550" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Vulnerability in resource allocation without limits or throttling in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006948" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-975" } ], "trust": 0.6 } }
var-202105-0691
Vulnerability from variot
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition. Several Siemens products contain resource exhaustion vulnerabilities.Denial of service (DoS) It may be put into a state. Siemens SmartVNC is an industrial control equipment of Siemens (Siemens), Germany.
SmartVNC has a resource management error vulnerability. Attackers can use this vulnerability to cause program denial of service. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202105-0691", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics sl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinamics gm150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic wincc runtime advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinamics sm150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinamics sm150i", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic wincc runtime advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gh150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics sm120", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics sh150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics sh150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sl150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sm120", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sm150i", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi comfort outdoor panels 7\"", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics gh150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sm150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics gl150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics gm150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "smartvnc", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37749" }, { "db": "JVNDB", "id": "JVNDB-2021-006950" }, { "db": "NVD", "id": "CVE-2021-27385" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-575" } ], "trust": 0.6 }, "cve": "CVE-2021-27385", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2021-27385", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2021-37749", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2021-27385", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-27385", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-27385", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2021-27385", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-37749", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202105-575", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-27385", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37749" }, { "db": "VULMON", "id": "CVE-2021-27385" }, { "db": "JVNDB", "id": "JVNDB-2021-006950" }, { "db": "CNNVD", "id": "CNNVD-202105-575" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "NVD", "id": "CVE-2021-27385" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition. Several Siemens products contain resource exhaustion vulnerabilities.Denial of service (DoS) It may be put into a state. Siemens SmartVNC is an industrial control equipment of Siemens (Siemens), Germany. \n\r\n\r\nSmartVNC has a resource management error vulnerability. Attackers can use this vulnerability to cause program denial of service. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements", "sources": [ { "db": "NVD", "id": "CVE-2021-27385" }, { "db": "JVNDB", "id": "JVNDB-2021-006950" }, { "db": "CNVD", "id": "CNVD-2021-37749" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULMON", "id": "CVE-2021-27385" } ], "trust": 2.79 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-27385", "trust": 3.9 }, { "db": "ICS CERT", "id": "ICSA-21-131-12", "trust": 3.1 }, { "db": "SIEMENS", "id": "SSA-286838", "trust": 1.7 }, { "db": "SIEMENS", "id": "SSA-538778", "trust": 1.7 }, { "db": "JVN", "id": "JVNVU91051134", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-006950", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-37749", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-21-131-04", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021051206", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202105-575", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-27385", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37749" }, { "db": "VULMON", "id": "CVE-2021-27385" }, { "db": "JVNDB", "id": "JVNDB-2021-006950" }, { "db": "CNNVD", "id": "CNNVD-202105-575" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "NVD", "id": "CVE-2021-27385" } ] }, "id": "VAR-202105-0691", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-37749" } ], "trust": 1.205898611111111 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37749" } ] }, "last_update_date": "2024-08-14T13:11:37.021000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-286838 Siemens\u00a0Security\u00a0Advisory", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "title": "Patch for Siemens SmartVNC Resource Management Error Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/268656" }, { "title": "Siemens SmartVNC Remediation of resource management error vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=151561" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=43c9c77785b8d29daef02185f41ca476" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=9465a8ef1f8c1b0042244cb02cfe271e" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37749" }, { "db": "VULMON", "id": "CVE-2021-27385" }, { "db": "JVNDB", "id": "JVNDB-2021-006950" }, { "db": "CNNVD", "id": "CNNVD-202105-575" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-400", "trust": 1.0 }, { "problemtype": "CWE-835", "trust": 1.0 }, { "problemtype": "Resource exhaustion (CWE-400) [ Other ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006950" }, { "db": "NVD", "id": "CVE-2021-27385" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.9, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu91051134/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-27385" }, { "trust": 0.8, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-131-12" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021051206" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/smartvnc-multiple-vulnerabilities-35360" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/400.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://cert-portal.siemens.com/productcert/txt/ssa-286838.txt" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37749" }, { "db": "VULMON", "id": "CVE-2021-27385" }, { "db": "JVNDB", "id": "JVNDB-2021-006950" }, { "db": "CNNVD", "id": "CNNVD-202105-575" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "NVD", "id": "CVE-2021-27385" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-37749" }, { "db": "VULMON", "id": "CVE-2021-27385" }, { "db": "JVNDB", "id": "JVNDB-2021-006950" }, { "db": "CNNVD", "id": "CNNVD-202105-575" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "NVD", "id": "CVE-2021-27385" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-05-28T00:00:00", "db": "CNVD", "id": "CNVD-2021-37749" }, { "date": "2021-05-12T00:00:00", "db": "VULMON", "id": "CVE-2021-27385" }, { "date": "2022-01-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-006950" }, { "date": "2021-05-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-575" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-05-12T14:15:11.727000", "db": "NVD", "id": "CVE-2021-27385" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-05-28T00:00:00", "db": "CNVD", "id": "CNVD-2021-37749" }, { "date": "2021-05-21T00:00:00", "db": "VULMON", "id": "CVE-2021-27385" }, { "date": "2022-01-26T07:30:00", "db": "JVNDB", "id": "JVNDB-2021-006950" }, { "date": "2022-10-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-575" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2022-10-25T19:56:01.580000", "db": "NVD", "id": "CVE-2021-27385" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-575" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens SmartVNC Resource Management Error Vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2021-37749" }, { "db": "CNNVD", "id": "CNNVD-202105-575" } ], "trust": 1.2 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "resource management error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-575" } ], "trust": 0.6 } }
cve-2021-27383
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:48:16.589Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SINAMICS GH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GL150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GM150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SL150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM120", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150i", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-770", "description": "CWE-770: Allocation of Resources Without Limits or Throttling", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-12T09:49:15", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-27383", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SINAMICS GH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GL150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GM150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SL150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM120", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150i", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-770: Allocation of Resources Without Limits or Throttling" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-27383", "datePublished": "2021-05-12T13:18:22", "dateReserved": "2021-02-18T00:00:00", "dateUpdated": "2024-08-03T20:48:16.589Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-27384
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11 | x_refsource_MISC |
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) |
Version: All versions < V15.1 Update 6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:48:16.461Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SINAMICS GH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GL150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GM150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SL150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM120", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150i", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-788", "description": "CWE-788: Access of Memory Location After End of Buffer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-12T09:49:16", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-27384", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SINAMICS GH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GL150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GM150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SL150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM120", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150i", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-788: Access of Memory Location After End of Buffer" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-27384", "datePublished": "2021-05-12T13:18:22", "dateReserved": "2021-02-18T00:00:00", "dateUpdated": "2024-08-03T20:48:16.461Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-27386
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_CONFIRM |
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) |
Version: All versions < V15.1 Update 6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:48:16.446Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SINAMICS GH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GL150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GM150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SL150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM120", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150i", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-401", "description": "CWE-401: Missing Release of Memory after Effective Lifetime", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-12T09:49:18", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-27386", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SINAMICS GH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GL150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GM150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SL150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM120", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150i", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-401: Missing Release of Memory after Effective Lifetime" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-27386", "datePublished": "2021-05-12T13:18:23", "dateReserved": "2021-02-18T00:00:00", "dateUpdated": "2024-08-03T20:48:16.446Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-15798
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02 | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf | x_refsource_CONFIRM |
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC HMI Comfort Panels (incl. SIPLUS variants) |
Version: All versions < V16 Update 3a |
||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T13:30:21.706Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 3a" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 3a" } ] }, { "product": "SINAMICS GH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GL150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GM150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SL150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM120", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150i", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions \u003c V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions \u003c V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306: Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-08-10T10:35:22", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-15798", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 3a" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 3a" } ] } }, { "product_name": "SINAMICS GH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GL150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GM150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SL150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM120", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150i", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions \u003c V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions \u003c V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-306: Missing Authentication for Critical Function" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-15798", "datePublished": "2021-02-09T15:38:17", "dateReserved": "2020-07-15T00:00:00", "dateUpdated": "2024-08-04T13:30:21.706Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-27385
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | x_refsource_MISC |
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) |
Version: All versions < V15.1 Update 6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:48:16.474Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SINAMICS GH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GL150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GM150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SL150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM120", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150i", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-12T09:49:17", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-27385", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SINAMICS GH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GL150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GM150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SL150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM120", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150i", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-400: Uncontrolled Resource Consumption" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-27385", "datePublished": "2021-05-12T13:18:23", "dateReserved": "2021-02-18T00:00:00", "dateUpdated": "2024-08-03T20:48:16.474Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }