All the vulnerabilites related to Siemens - SIMIT V10
cve-2023-52891
Vulnerability from cvelistv5
Published
2024-07-09 12:04
Modified
2024-08-02 23:18
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO (All versions < V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions < V11.1). Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the server.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC Energy Manager Basic |
Version: 0 < V7.5 |
||||||||||||||||||||
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:siemens:simatic_energy_manager_basic:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_energy_manager_basic", "vendor": "siemens", "versions": [ { "lessThan": "V7.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:simatic_energy_manager_pro:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_energy_manager_pro", "vendor": "siemens", "versions": [ { "lessThan": "V7.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_ipc_diagbase:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_ipc_diagbase", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_ipc_diagmonitor:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_ipc_diagmonitor", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:simit_v10:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simit_v10", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:simit_v11:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simit_v11", "vendor": "siemens", "versions": [ { "lessThan": "V11.1", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-52891", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-07-09T13:26:14.481281Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-09T13:41:12.246Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T23:18:41.378Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-088132.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC Energy Manager Basic", "vendor": "Siemens", "versions": [ { "lessThan": "V7.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Energy Manager PRO", "vendor": "Siemens", "versions": [ { "lessThan": "V7.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC IPC DiagBase", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC IPC DiagMonitor", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMIT V10", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMIT V11", "vendor": "Siemens", "versions": [ { "lessThan": "V11.1", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions \u003c V7.5), SIMATIC Energy Manager PRO (All versions \u003c V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions \u003c V11.1). Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the server." } ], "metrics": [ { "cvssV3_1": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-1325", "description": "CWE-1325: Improperly Controlled Sequential Memory Allocation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-07-09T12:04:42.619Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-088132.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-52891", "datePublished": "2024-07-09T12:04:42.619Z", "dateReserved": "2024-06-21T15:06:40.772Z", "dateUpdated": "2024-08-02T23:18:41.378Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }