All the vulnerabilites related to Siemens - SIMATIC WinCC V7.4
cve-2023-46280
Vulnerability from cvelistv5
Published
2024-05-14 10:01
Modified
2024-12-10 13:53
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions < V5.0 SP2), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions < V16 Update 8), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions < V18 SP1), SIMATIC NET PC Software V19 (All versions < V19 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PDM V9.2 (All versions < V9.2 SP2 Upd3), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 Upd3), SIMATIC S7-PCT (All versions < V3.5 SP3 Update 6), SIMATIC STEP 7 V5 (All versions < V5.7 SP3), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions < V3.18 P025), SIMATIC WinCC OA V3.19 (All versions < V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5), SINAMICS Startdrive (All versions < V19 SP1), SINEC NMS (All versions < V3.0), SINEC NMS (All versions < V3.0 SP1), SINUMERIK ONE virtual (All versions < V6.23), SINUMERIK PLC Programming Tool (All versions < V3.3.12), TIA Portal Cloud Connector (All versions < V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 2). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel.
References
Impacted products
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2023-46280", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-05-29T14:20:28.448026Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:22:08.819Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T20:37:40.324Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-962515.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Security Configuration Tool (SCT)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Automation Tool", "vendor": "Siemens", "versions": [ { "lessThan": "V5.0 SP2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC BATCH V9.1", "vendor": "Siemens", "versions": [ { "lessThan": "V9.1 SP2 Upd5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V16", "vendor": "Siemens", "versions": [ { "lessThan": "V16 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V17", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V19", "vendor": "Siemens", "versions": [ { "lessThan": "V19 Update 2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V9.1", "vendor": "Siemens", "versions": [ { "lessThan": "V9.1 SP2 UC05", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PDM V9.2", "vendor": "Siemens", "versions": [ { "lessThan": "V9.2 SP2 Upd3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Route Control V9.1", "vendor": "Siemens", "versions": [ { "lessThan": "V9.1 SP2 Upd3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-PCT", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5 SP3 Update 6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC STEP 7 V5", "vendor": "Siemens", "versions": [ { "lessThan": "V5.7 SP3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC OA V3.17", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC OA V3.18", "vendor": "Siemens", "versions": [ { "lessThan": "V3.18 P025", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC OA V3.19", "vendor": "Siemens", "versions": [ { "lessThan": "V3.19 P010", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V16", "vendor": "Siemens", "versions": [ { "lessThan": "V16 Update 6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V19", "vendor": "Siemens", "versions": [ { "lessThan": "V19 Update 2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.5", "vendor": "Siemens", "versions": [ { "lessThan": "V7.5 SP2 Update 17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V8.0", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0 Update 5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS Startdrive", "vendor": "Siemens", "versions": [ { "lessThan": "V19 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK ONE virtual", "vendor": "Siemens", "versions": [ { "lessThan": "V6.23", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK PLC Programming Tool", "vendor": "Siemens", "versions": [ { "lessThan": "V3.3.12", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "TIA Portal Cloud Connector", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V15.1", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V19", "vendor": "Siemens", "versions": [ { "lessThan": "V19 Update 2", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions \u003c V5.0 SP2), SIMATIC BATCH V9.1 (All versions \u003c V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions \u003c V16 Update 8), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions \u003c V18 SP1), SIMATIC NET PC Software V19 (All versions \u003c V19 Update 2), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC PDM V9.2 (All versions \u003c V9.2 SP2 Upd3), SIMATIC Route Control V9.1 (All versions \u003c V9.1 SP2 Upd3), SIMATIC S7-PCT (All versions \u003c V3.5 SP3 Update 6), SIMATIC STEP 7 V5 (All versions \u003c V5.7 SP3), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions \u003c V3.18 P025), SIMATIC WinCC OA V3.19 (All versions \u003c V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions \u003c V17 Update 8), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions \u003c V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 5), SINAMICS Startdrive (All versions \u003c V19 SP1), SINEC NMS (All versions \u003c V3.0), SINEC NMS (All versions \u003c V3.0 SP1), SINUMERIK ONE virtual (All versions \u003c V6.23), SINUMERIK PLC Programming Tool (All versions \u003c V3.3.12), TIA Portal Cloud Connector (All versions \u003c V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions \u003c V19 Update 2). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 8.2, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-10T13:53:28.579Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-962515.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-784301.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-331112.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-46280", "datePublished": "2024-05-14T10:01:52.069Z", "dateReserved": "2023-10-20T08:02:52.794Z", "dateUpdated": "2024-12-10T13:53:28.579Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-40359
Vulnerability from cvelistv5
Published
2021-11-09 11:32
Modified
2024-08-04 02:44
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd4), OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 6), SIMATIC NET PC Software V17 (All versions < V17 SP1), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | OpenPCS 7 V8.2 |
Version: All versions |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T02:44:09.625Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "OpenPCS 7 V8.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "OpenPCS 7 V9.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.0 Upd4" } ] }, { "defaultStatus": "unknown", "product": "OpenPCS 7 V9.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC BATCH V8.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC BATCH V9.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC BATCH V9.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 6" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V17", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V17 SP1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V8.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V9.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.0 SP3 UC04" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V9.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.1 SP1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Route Control V8.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Route Control V9.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Route Control V9.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V15 and earlier", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15 SP1 Update 7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 5" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V17", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V17 Update 2" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.4 SP1 Update 19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.5", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.5 SP2 Update 5" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions \u003c V9.0 Upd4), OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Update 6), SIMATIC NET PC Software V17 (All versions \u003c V17 SP1), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 5). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.7, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-11T09:01:59.282Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-40359", "datePublished": "2021-11-09T11:32:05", "dateReserved": "2021-09-01T00:00:00", "dateUpdated": "2024-08-04T02:44:09.625Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-40363
Vulnerability from cvelistv5
Published
2022-02-09 15:17
Modified
2024-08-04 02:44
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V17 (All versions <= V17 Update 4), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The affected component stores the credentials of a local system account in a potentially publicly accessible project file using an outdated cipher algorithm. An attacker may use this to brute force the credentials and take over the system.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC PCS 7 V8.2 |
Version: All versions |
||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T02:44:09.640Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC PCS 7 V8.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC PCS 7 V9.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC PCS 7 V9.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.1 SP1" } ] }, { "product": "SIMATIC WinCC V15 and earlier", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15 SP1 Update 7" } ] }, { "product": "SIMATIC WinCC V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 5" } ] }, { "product": "SIMATIC WinCC V17", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V17 Update 2" } ] }, { "product": "SIMATIC WinCC V17", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c= V17 Update 4" } ] }, { "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.4 SP1 Update 19" } ] }, { "product": "SIMATIC WinCC V7.5", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.5 SP2 Update 6" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V17 (All versions \u003c= V17 Update 4), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 6). The affected component stores the credentials of a local system account in a potentially publicly accessible project file using an outdated cipher algorithm. An attacker may use this to brute force the credentials and take over the system." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-538", "description": "CWE-538: Insertion of Sensitive Information into Externally-Accessible File or Directory", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-10T11:17:13", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-40363", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC PCS 7 V8.2", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC PCS 7 V9.0", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC PCS 7 V9.1", "version": { "version_data": [ { "version_value": "All versions \u003c V9.1 SP1" } ] } }, { "product_name": "SIMATIC WinCC V15 and earlier", "version": { "version_data": [ { "version_value": "All versions \u003c V15 SP1 Update 7" } ] } }, { "product_name": "SIMATIC WinCC V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 5" } ] } }, { "product_name": "SIMATIC WinCC V17", "version": { "version_data": [ { "version_value": "All versions \u003c V17 Update 2" } ] } }, { "product_name": "SIMATIC WinCC V17", "version": { "version_data": [ { "version_value": "All versions \u003c= V17 Update 4" } ] } }, { "product_name": "SIMATIC WinCC V7.4", "version": { "version_data": [ { "version_value": "All versions \u003c V7.4 SP1 Update 19" } ] } }, { "product_name": "SIMATIC WinCC V7.5", "version": { "version_data": [ { "version_value": "All versions \u003c V7.5 SP2 Update 6" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V17 (All versions \u003c= V17 Update 4), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 6). The affected component stores the credentials of a local system account in a potentially publicly accessible project file using an outdated cipher algorithm. An attacker may use this to brute force the credentials and take over the system." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-538: Insertion of Sensitive Information into Externally-Accessible File or Directory" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-40363", "datePublished": "2022-02-09T15:17:04", "dateReserved": "2021-09-01T00:00:00", "dateUpdated": "2024-08-04T02:44:09.640Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-40358
Vulnerability from cvelistv5
Published
2021-11-09 11:32
Modified
2024-08-04 02:44
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). Legitimate file operations on the web server of the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read, write or delete unexpected critical files.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC PCS 7 V8.2 |
Version: All versions |
||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T02:44:09.554Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V8.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V9.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.0 SP3 UC04" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V9.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.1 SP1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V15 and earlier", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15 SP1 Update 7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 5" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V17", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V17 Update 2" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.4 SP1 Update 19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.5", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.5 SP2 Update 5" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 5). Legitimate file operations on the web server of the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read, write or delete unexpected critical files." } ], "metrics": [ { "cvssV3_1": { "baseScore": 9.9, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-11T09:01:58.251Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-40358", "datePublished": "2021-11-09T11:32:04", "dateReserved": "2021-09-01T00:00:00", "dateUpdated": "2024-08-04T02:44:09.554Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-40364
Vulnerability from cvelistv5
Published
2021-11-09 11:32
Modified
2024-08-04 02:44
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). The affected systems store sensitive information in log files. An attacker with access to the log files could publicly expose the information or reuse it to develop further attacks on the system.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC PCS 7 V8.2 |
Version: All versions |
||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T02:44:09.470Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V8.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V9.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.0 SP3 UC04" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V9.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.1 SP1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V15 and earlier", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15 SP1 Update 7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 5" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V17", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V17 Update 2" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.4 SP1 Update 19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.5", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.5 SP2 Update 5" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 5). The affected systems store sensitive information in log files. An attacker with access to the log files could publicly expose the information or reuse it to develop further attacks on the system." } ], "metrics": [ { "cvssV3_1": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-532", "description": "CWE-532: Insertion of Sensitive Information into Log File", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-11T09:02:00.354Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-40364", "datePublished": "2021-11-09T11:32:06", "dateReserved": "2021-09-01T00:00:00", "dateUpdated": "2024-08-04T02:44:09.470Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-35783
Vulnerability from cvelistv5
Published
2024-09-10 09:36
Modified
2024-11-12 12:49
Severity ?
9.1 (Critical) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C
9.4 (Critical) - CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
9.4 (Critical) - CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions), SIMATIC Information Server 2022 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions), SIMATIC Process Historian 2022 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC BATCH V9.1 |
Version: 0 < * |
||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:18:*:*:*:*:*:*:*", "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:19:*:*:*:*:*:*:*", "cpe:2.3:h:siemens:simatic_process_historian:2020:-:*:*:*:*:*:*", "cpe:2.3:a:siemens:simatic_process_historian:2022:*:*:*:*:*:*:*", "cpe:2.3:a:siemens:simatic_pcs7:*:*:*:*:*:*:*:*", "cpe:2.3:a:siemens:simatic_information_server:2020:-:*:*:*:*:*:*", "cpe:2.3:a:siemens:simatic_information_server:2022:*:*:*:*:*:*:*", "cpe:2.3:a:siemens:simatic_batch:9.1:-:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_batch", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_wincc", "vendor": "siemens", "versions": [ { "lessThan": "7.5_sp2_update_18", "status": "affected", "version": "7.4", "versionType": "custom" }, { "lessThan": "8.0_update_5", "status": "affected", "version": "8.0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-35783", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-09-10T15:12:46.700884Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-10T17:31:08.389Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC BATCH V9.1", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Information Server 2020", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Information Server 2022", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V9.1", "vendor": "Siemens", "versions": [ { "lessThan": "V9.1 SP2 UC06", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Process Historian 2020", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Process Historian 2022", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V19", "vendor": "Siemens", "versions": [ { "lessThan": "V19 Update 3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.5", "vendor": "Siemens", "versions": [ { "lessThan": "V7.5 SP2 Update 18", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V8.0", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0 Update 5", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions), SIMATIC Information Server 2022 (All versions), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions), SIMATIC Process Historian 2022 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges." } ], "metrics": [ { "cvssV3_1": { "baseScore": 9.1, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 9.4, "baseSeverity": "CRITICAL", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-250", "description": "CWE-250: Execution with Unnecessary Privileges", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-12T12:49:30.900Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-629254.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-35783", "datePublished": "2024-09-10T09:36:32.225Z", "dateReserved": "2024-05-17T11:07:53.264Z", "dateUpdated": "2024-11-12T12:49:30.900Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-28831
Vulnerability from cvelistv5
Published
2023-09-12 09:32
Modified
2024-12-10 13:53
Severity ?
EPSS score ?
Summary
The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation.
This could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC BRAUMAT |
Version: 0 < V8.1 SP1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T13:51:38.545Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-711309.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-118850.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-711309.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-118850.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC BRAUMAT", "vendor": "Siemens", "versions": [ { "lessThan": "V8.1 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Cloud Connect 7 CC712", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Cloud Connect 7 CC716", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Comfort/Mobile RT", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Drive Controller CPU 1504D TF", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Drive Controller CPU 1504D TF", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "V3.0.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Drive Controller CPU 1507D TF", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Drive Controller CPU 1507D TF", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "V3.0.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V21.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V30.1.0", "status": "affected", "version": "V30.0.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC IPC DiagMonitor", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V14", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V16", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 SP1 Update 1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V9.1", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS neo V4.0", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1510SP F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1510SP F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1510SP-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1510SP-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511C-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511C-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511T-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511T-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511TF-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511TF-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1512C-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1512C-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1512SP F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1512SP F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1512SP-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1512SP-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1513-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1513-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1513-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1513F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1513F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1513F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1514SP F-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1514SP-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1514SPT F-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1514SPT-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515F-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515F-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515F-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515T-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515T-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515TF-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515TF-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1516T-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1516TF-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1517-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1517F-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1517T-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1517TF-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1518T-4 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1518TF-4 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller V2", "vendor": "Siemens", "versions": [ { "lessThan": "V21.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller V3", "vendor": "Siemens", "versions": [ { "lessThan": "V30.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-PLCSIM Advanced", "vendor": "Siemens", "versions": [ { "lessThan": "V5.0 Update 2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC SISTAR", "vendor": "Siemens", "versions": [ { "lessThan": "V8.1 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC OA V3.17", "vendor": "Siemens", "versions": [ { "lessThan": "V3.17 P029", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC OA V3.18", "vendor": "Siemens", "versions": [ { "lessThan": "V3.18 P019", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC OA V3.19", "vendor": "Siemens", "versions": [ { "lessThan": "V3.19 P005", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC OPC UA Client", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0.0.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V16", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V17", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V18", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V19", "vendor": "Siemens", "versions": [ { "lessThan": "V19 Update 2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Unified OPC UA Server", "vendor": "Siemens", "versions": [ { "lessThan": "V5.0.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.5", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V8.0", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0 Update 5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK MC", "vendor": "Siemens", "versions": [ { "lessThan": "V1.22", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK ONE", "vendor": "Siemens", "versions": [ { "lessThan": "V6.22", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1510SP-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1510SP-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1512SP-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1512SP-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1513-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1513-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1513-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1513-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1513F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1513F-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1515F-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1515F-2 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1515F-2 PN RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V2.9.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1518F-4 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation.\r\n\r\nThis could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-190", "description": "CWE-190: Integer Overflow or Wraparound", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-10T13:53:25.548Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-711309.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-118850.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-711309.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-118850.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-28831", "datePublished": "2023-09-12T09:32:06.153Z", "dateReserved": "2023-03-24T15:17:33.934Z", "dateUpdated": "2024-12-10T13:53:25.548Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-40360
Vulnerability from cvelistv5
Published
2022-02-09 15:17
Modified
2024-08-04 02:44
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC PCS 7 V8.2 |
Version: All versions |
||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T02:44:09.157Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC PCS 7 V8.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC PCS 7 V9.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC PCS 7 V9.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.1 SP1" } ] }, { "product": "SIMATIC WinCC V15 and earlier", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15 SP1 Update 7" } ] }, { "product": "SIMATIC WinCC V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 5" } ] }, { "product": "SIMATIC WinCC V17", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V17 Update 2" } ] }, { "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.4 SP1 Update 19" } ] }, { "product": "SIMATIC WinCC V7.5", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.5 SP2 Update 6" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-200", "description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-05-10T09:46:42", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-40360", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC PCS 7 V8.2", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC PCS 7 V9.0", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC PCS 7 V9.1", "version": { "version_data": [ { "version_value": "All versions \u003c V9.1 SP1" } ] } }, { "product_name": "SIMATIC WinCC V15 and earlier", "version": { "version_data": [ { "version_value": "All versions \u003c V15 SP1 Update 7" } ] } }, { "product_name": "SIMATIC WinCC V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 5" } ] } }, { "product_name": "SIMATIC WinCC V17", "version": { "version_data": [ { "version_value": "All versions \u003c V17 Update 2" } ] } }, { "product_name": "SIMATIC WinCC V7.4", "version": { "version_data": [ { "version_value": "All versions \u003c V7.4 SP1 Update 19" } ] } }, { "product_name": "SIMATIC WinCC V7.5", "version": { "version_data": [ { "version_value": "All versions \u003c V7.5 SP2 Update 6" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-40360", "datePublished": "2022-02-09T15:17:03", "dateReserved": "2021-09-01T00:00:00", "dateUpdated": "2024-08-04T02:44:09.157Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-4832
Vulnerability from cvelistv5
Published
2018-04-24 17:00
Modified
2024-08-05 05:18
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions < V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions < V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions < V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions < V8.2 Upd10), SIMATIC BATCH V9.0 (All versions < V9.0 SP1), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions < 15 SP1), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Upd5), SIMATIC WinCC V7.2 and earlier (All versions < WinCC 7.2 Upd 15), SIMATIC WinCC V7.3 (All versions < WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 4), SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf | x_refsource_MISC | |
http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | OpenPCS 7 V7.1 and earlier |
Version: All versions |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T05:18:26.633Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "OpenPCS 7 V7.1 and earlier", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "OpenPCS 7 V8.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "OpenPCS 7 V8.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.1 Upd5" } ] }, { "product": "OpenPCS 7 V8.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "OpenPCS 7 V9.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.0 Upd1" } ] }, { "product": "SIMATIC BATCH V7.1 and earlier", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC BATCH V8.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.0 SP1 Upd21" } ] }, { "product": "SIMATIC BATCH V8.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.1 SP1 Upd16" } ] }, { "product": "SIMATIC BATCH V8.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.2 Upd10" } ] }, { "product": "SIMATIC BATCH V9.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.0 SP1" } ] }, { "product": "SIMATIC NET PC Software V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 14" } ] }, { "product": "SIMATIC NET PC Software V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 15 SP1" } ] }, { "product": "SIMATIC PCS 7 V7.1 and earlier", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC PCS 7 V8.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC PCS 7 V8.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC PCS 7 V8.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.2 SP1" } ] }, { "product": "SIMATIC PCS 7 V9.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.0 SP1" } ] }, { "product": "SIMATIC Route Control V7.1 and earlier", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC Route Control V8.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC Route Control V8.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC Route Control V8.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC Route Control V9.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.0 Upd1" } ] }, { "product": "SIMATIC WinCC Runtime Professional V13", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13 SP2 Upd2" } ] }, { "product": "SIMATIC WinCC Runtime Professional V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Upd5" } ] }, { "product": "SIMATIC WinCC V7.2 and earlier", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c WinCC 7.2 Upd 15" } ] }, { "product": "SIMATIC WinCC V7.3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c WinCC 7.3 Upd 16" } ] }, { "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.4 SP1 Upd 4" } ] }, { "product": "SPPA-T3000 Application Server", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c Service Pack R8.2 SP2" } ] } ], "datePublic": "2018-03-27T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions \u003c V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions \u003c V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions \u003c V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions \u003c V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions \u003c V8.2 Upd10), SIMATIC BATCH V9.0 (All versions \u003c V9.0 SP1), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions \u003c 15 SP1), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions \u003c V9.0 Upd1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Upd5), SIMATIC WinCC V7.2 and earlier (All versions \u003c WinCC 7.2 Upd 15), SIMATIC WinCC V7.3 (All versions \u003c WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 4), SPPA-T3000 Application Server (All versions \u003c Service Pack R8.2 SP2). Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20: Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-12T09:06:48", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2018-4832", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "OpenPCS 7 V7.1 and earlier", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "OpenPCS 7 V8.0", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "OpenPCS 7 V8.1", "version": { "version_data": [ { "version_value": "All versions \u003c V8.1 Upd5" } ] } }, { "product_name": "OpenPCS 7 V8.2", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "OpenPCS 7 V9.0", "version": { "version_data": [ { "version_value": "All versions \u003c V9.0 Upd1" } ] } }, { "product_name": "SIMATIC BATCH V7.1 and earlier", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC BATCH V8.0", "version": { "version_data": [ { "version_value": "All versions \u003c V8.0 SP1 Upd21" } ] } }, { "product_name": "SIMATIC BATCH V8.1", "version": { "version_data": [ { "version_value": "All versions \u003c V8.1 SP1 Upd16" } ] } }, { "product_name": "SIMATIC BATCH V8.2", "version": { "version_data": [ { "version_value": "All versions \u003c V8.2 Upd10" } ] } }, { "product_name": "SIMATIC BATCH V9.0", "version": { "version_data": [ { "version_value": "All versions \u003c V9.0 SP1" } ] } }, { "product_name": "SIMATIC NET PC Software V14", "version": { "version_data": [ { "version_value": "All versions \u003c V14 SP1 Update 14" } ] } }, { "product_name": "SIMATIC NET PC Software V15", "version": { "version_data": [ { "version_value": "All versions \u003c 15 SP1" } ] } }, { "product_name": "SIMATIC PCS 7 V7.1 and earlier", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC PCS 7 V8.0", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC PCS 7 V8.1", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC PCS 7 V8.2", "version": { "version_data": [ { "version_value": "All versions \u003c V8.2 SP1" } ] } }, { "product_name": "SIMATIC PCS 7 V9.0", "version": { "version_data": [ { "version_value": "All versions \u003c V9.0 SP1" } ] } }, { "product_name": "SIMATIC Route Control V7.1 and earlier", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC Route Control V8.0", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC Route Control V8.1", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC Route Control V8.2", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC Route Control V9.0", "version": { "version_data": [ { "version_value": "All versions \u003c V9.0 Upd1" } ] } }, { "product_name": "SIMATIC WinCC Runtime Professional V13", "version": { "version_data": [ { "version_value": "All versions \u003c V13 SP2 Upd2" } ] } }, { "product_name": "SIMATIC WinCC Runtime Professional V14", "version": { "version_data": [ { "version_value": "All versions \u003c V14 SP1 Upd5" } ] } }, { "product_name": "SIMATIC WinCC V7.2 and earlier", "version": { "version_data": [ { "version_value": "All versions \u003c WinCC 7.2 Upd 15" } ] } }, { "product_name": "SIMATIC WinCC V7.3", "version": { "version_data": [ { "version_value": "All versions \u003c WinCC 7.3 Upd 16" } ] } }, { "product_name": "SIMATIC WinCC V7.4", "version": { "version_data": [ { "version_value": "All versions \u003c V7.4 SP1 Upd 4" } ] } }, { "product_name": "SPPA-T3000 Application Server", "version": { "version_data": [ { "version_value": "All versions \u003c Service Pack R8.2 SP2" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions \u003c V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions \u003c V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions \u003c V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions \u003c V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions \u003c V8.2 Upd10), SIMATIC BATCH V9.0 (All versions \u003c V9.0 SP1), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions \u003c 15 SP1), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions \u003c V9.0 Upd1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Upd5), SIMATIC WinCC V7.2 and earlier (All versions \u003c WinCC 7.2 Upd 15), SIMATIC WinCC V7.3 (All versions \u003c WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 4), SPPA-T3000 Application Server (All versions \u003c Service Pack R8.2 SP2). Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-20: Improper Input Validation" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf" }, { "name": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html", "refsource": "MISC", "url": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2018-4832", "datePublished": "2018-04-24T17:00:00", "dateReserved": "2018-01-02T00:00:00", "dateUpdated": "2024-08-05T05:18:26.633Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-48364
Vulnerability from cvelistv5
Published
2024-02-13 08:59
Modified
2024-09-10 09:36
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain malformed RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | OpenPCS 7 V9.1 |
Version: All versions < V9.1 SP2 UC05 |
||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2023-48364", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-02-13T16:04:15.175349Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-05T17:21:43.053Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T21:30:34.447Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "OpenPCS 7 V9.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.1 SP2 UC05" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC BATCH V9.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.1 SP2 UC05" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V9.1", "vendor": "Siemens", "versions": [ { "lessThan": "V9.1 SP2 UC05", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Route Control V9.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.1 SP2 UC05" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V19", "vendor": "Siemens", "versions": [ { "lessThan": "V19 Update 2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.5", "vendor": "Siemens", "versions": [ { "lessThan": "V7.5 SP2 Update 15", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V8.0", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0 Update 4", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in OpenPCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain malformed RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-476", "description": "CWE-476: NULL Pointer Dereference", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:36:24.190Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-48364", "datePublished": "2024-02-13T08:59:56.648Z", "dateReserved": "2023-11-15T17:20:32.751Z", "dateUpdated": "2024-09-10T09:36:24.190Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-48363
Vulnerability from cvelistv5
Published
2024-02-13 08:59
Modified
2024-09-10 09:36
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call)
communication protocol in the affected products do not
properly handle certain unorganized RPC messages. An
attacker could use this vulnerability to cause a denial of service
condition in the RPC server.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | OpenPCS 7 V9.1 |
Version: All versions < V9.1 SP2 UC05 |
||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2023-48363", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-02-13T16:37:22.994141Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-05T17:21:43.194Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T21:30:34.556Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "OpenPCS 7 V9.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.1 SP2 UC05" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC BATCH V9.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.1 SP2 UC05" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V9.1", "vendor": "Siemens", "versions": [ { "lessThan": "V9.1 SP2 UC05", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Route Control V9.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.1 SP2 UC05" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V19", "vendor": "Siemens", "versions": [ { "lessThan": "V19 Update 2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.5", "vendor": "Siemens", "versions": [ { "lessThan": "V7.5 SP2 Update 15", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V8.0", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0 Update 4", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in OpenPCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 4). The implementation of the RPC (Remote Procedure call) \r\ncommunication protocol in the affected products do not \r\nproperly handle certain unorganized RPC messages. An \r\nattacker could use this vulnerability to cause a denial of service \r\ncondition in the RPC server." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-476", "description": "CWE-476: NULL Pointer Dereference", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:36:22.958Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-48363", "datePublished": "2024-02-13T08:59:55.432Z", "dateReserved": "2023-11-15T17:20:32.751Z", "dateUpdated": "2024-09-10T09:36:22.958Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-30321
Vulnerability from cvelistv5
Published
2024-07-09 12:04
Modified
2024-11-12 12:49
Severity ?
5.9 (Medium) - CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N
8.2 (High) - CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
8.2 (High) - CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 23), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products do not properly handle certain requests to their web application, which may lead to the leak of privileged information.
This could allow an unauthenticated remote attacker to retrieve information such as users and passwords.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC PCS 7 V9.1 |
Version: 0 < V9.1 SP2 UC05 |
||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T01:32:07.025Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-883918.html" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_pcs_7", "vendor": "siemens", "versions": [ { "lessThan": "10", "status": "affected", "version": "9.1", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_wincc", "vendor": "siemens", "versions": [ { "lessThan": "7.4_sp1_update_23", "status": "affected", "version": "7.4", "versionType": "custom" }, { "lessThan": "7.5_sp2_update_17", "status": "affected", "version": "7.5", "versionType": "custom" }, { "lessThan": "8.0_update_5", "status": "affected", "version": "8.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_wincc_runtime_professional", "vendor": "siemens", "versions": [ { "lessThan": "19", "status": "affected", "version": "18", "versionType": "custom" }, { "lessThan": "19_update_2", "status": "affected", "version": "19", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-30321", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-08-19T16:20:35.487955Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-19T16:49:59.084Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V9.1", "vendor": "Siemens", "versions": [ { "lessThan": "V9.1 SP2 UC05", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V19", "vendor": "Siemens", "versions": [ { "lessThan": "V19 Update 2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "lessThan": "V7.4 SP1 Update 23", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.5", "vendor": "Siemens", "versions": [ { "lessThan": "V7.5 SP2 Update 17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V8.0", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0 Update 5", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 23), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 5). The affected products do not properly handle certain requests to their web application, which may lead to the leak of privileged information.\r\nThis could allow an unauthenticated remote attacker to retrieve information such as users and passwords." } ], "metrics": [ { "cvssV3_1": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 8.2, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-359", "description": "CWE-359: Exposure of Private Personal Information to an Unauthorized Actor", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-12T12:49:28.352Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-883918.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-30321", "datePublished": "2024-07-09T12:04:43.997Z", "dateReserved": "2024-03-26T16:42:16.797Z", "dateUpdated": "2024-11-12T12:49:28.352Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-19282
Vulnerability from cvelistv5
Published
2020-03-10 19:16
Modified
2024-08-05 02:09
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions < V8.2 Upd12), SIMATIC BATCH V9.0 (All versions < V9.0 SP1 Upd5), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15.1 (All versions < V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (All versions < V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition.
Successful exploitation requires no system privileges and no user interaction.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | OpenPCS 7 V8.1 |
Version: All versions |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:09:39.657Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-270778.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "OpenPCS 7 V8.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "OpenPCS 7 V8.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "OpenPCS 7 V9.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.0 Upd3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC BATCH V8.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC BATCH V8.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.2 Upd12" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC BATCH V9.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.0 SP1 Upd5" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 14" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V8.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V8.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V9.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.0 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Route Control V8.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Route Control V8.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Route Control V9.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.0 Upd4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC (TIA Portal) V13", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13 SP2" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC (TIA Portal) V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 10" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC (TIA Portal) V15.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 5" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.4 SP1 Update 14" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.5", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.5 SP1 Update 1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions \u003c V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions \u003c V8.2 Upd12), SIMATIC BATCH V9.0 (All versions \u003c V9.0 SP1 Upd5), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions \u003c V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15.1 (All versions \u003c V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (All versions \u003c V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition.\nSuccessful exploitation requires no system privileges and no user interaction." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-131", "description": "CWE-131: Incorrect Calculation of Buffer Size", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-11T09:01:49.748Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-270778.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-19282", "datePublished": "2020-03-10T19:16:17", "dateReserved": "2019-11-26T00:00:00", "dateUpdated": "2024-08-05T02:09:39.657Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-7580
Vulnerability from cvelistv5
Published
2020-06-10 00:00
Modified
2024-08-04 09:33
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC Automation Tool |
Version: All versions < V4 SP2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T09:33:19.492Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf" }, { "tags": [ "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC Automation Tool", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4 SP2" } ] }, { "product": "SIMATIC NET PC Software V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 14" } ] }, { "product": "SIMATIC NET PC Software V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC NET PC Software V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Upd3" } ] }, { "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0 SP1" } ] }, { "product": "SIMATIC ProSave", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V17" } ] }, { "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V21.8" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V13", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13 SP2 Update 4" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 10" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 5" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 2" } ] }, { "product": "SIMATIC STEP 7 V5", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.6 SP2 HF3" } ] }, { "product": "SIMATIC WinCC OA V3.16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.16 P018" } ] }, { "product": "SIMATIC WinCC OA V3.17", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.17 P003" } ] }, { "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 2" } ] }, { "product": "SIMATIC WinCC Runtime Professional V13", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13 SP2 Update 4" } ] }, { "product": "SIMATIC WinCC Runtime Professional V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 10" } ] }, { "product": "SIMATIC WinCC Runtime Professional V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 5" } ] }, { "product": "SIMATIC WinCC Runtime Professional V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 2" } ] }, { "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.4 SP1 Update 14" } ] }, { "product": "SIMATIC WinCC V7.5", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.5 SP1 Update 3" } ] }, { "product": "SINAMICS STARTER", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.4 HF2" } ] }, { "product": "SINAMICS Startdrive", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V16 Update 3" } ] }, { "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0 SP2" } ] }, { "product": "SINEMA Server", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP3" } ] }, { "product": "SINUMERIK ONE virtual", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V6.14" } ] }, { "product": "SINUMERIK Operate", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V6.14" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC Automation Tool (All versions \u003c V4 SP2), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Upd3), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC ProSave (All versions \u003c V17), SIMATIC S7-1500 Software Controller (All versions \u003c V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMATIC STEP 7 V5 (All versions \u003c V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions \u003c V3.16 P018), SIMATIC WinCC OA V3.17 (All versions \u003c V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions \u003c V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 3), SINAMICS STARTER (All Versions \u003c V5.4 HF2), SINAMICS Startdrive (All Versions \u003c V16 Update 3), SINEC NMS (All versions \u003c V1.0 SP2), SINEMA Server (All versions \u003c V14 SP3), SINUMERIK ONE virtual (All Versions \u003c V6.14), SINUMERIK Operate (All Versions \u003c V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-428", "description": "CWE-428: Unquoted Search Path or Element", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-13T00:00:00", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf" }, { "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-7580", "datePublished": "2020-06-10T00:00:00", "dateReserved": "2020-01-21T00:00:00", "dateUpdated": "2024-08-04T09:33:19.492Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-24287
Vulnerability from cvelistv5
Published
2022-05-10 09:46
Modified
2024-08-03 04:07
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC06), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1 UC01), SIMATIC WinCC Runtime Professional V16 and earlier (All versions), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Upd4), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 21), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 8). A missing printer configuration on the host could allow an authenticated attacker to escape the WinCC Kiosk Mode.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC PCS 7 V8.2 |
Version: All versions |
||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T04:07:02.492Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-363107.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V8.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V9.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.0 SP3 UC06" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V9.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.1 SP1 UC01" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V16 and earlier", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V17", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V17 Upd4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.4 SP1 Update 21" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.5", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.5 SP2 Update 8" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3 UC06), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1 UC01), SIMATIC WinCC Runtime Professional V16 and earlier (All versions), SIMATIC WinCC Runtime Professional V17 (All versions \u003c V17 Upd4), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 21), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 8). A missing printer configuration on the host could allow an authenticated attacker to escape the WinCC Kiosk Mode." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-1188", "description": "CWE-1188: Insecure Default Initialization of Resource", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-14T11:03:11.010Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-363107.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-24287", "datePublished": "2022-05-10T09:46:57", "dateReserved": "2022-02-01T00:00:00", "dateUpdated": "2024-08-03T04:07:02.492Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }