All the vulnerabilites related to Siemens - SIMATIC WinCC Runtime Professional V14
cve-2020-7580
Vulnerability from cvelistv5
Published
2020-06-10 00:00
Modified
2024-08-04 09:33
Severity ?
Summary
A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.
Impacted products
Vendor Product Version
Siemens SIMATIC NET PC Software V14 Version: All versions < V14 SP1 Update 14
Siemens SIMATIC NET PC Software V15 Version: All versions
Siemens SIMATIC NET PC Software V16 Version: All versions < V16 Upd3
Siemens SIMATIC PCS neo Version: All versions < V3.0 SP1
Siemens SIMATIC ProSave Version: All versions < V17
Siemens SIMATIC S7-1500 Software Controller Version: All versions < V21.8
Siemens SIMATIC STEP 7 (TIA Portal) V13 Version: All versions < V13 SP2 Update 4
Siemens SIMATIC STEP 7 (TIA Portal) V14 Version: All versions < V14 SP1 Update 10
Siemens SIMATIC STEP 7 (TIA Portal) V15 Version: All versions < V15.1 Update 5
Siemens SIMATIC STEP 7 (TIA Portal) V16 Version: All versions < V16 Update 2
Siemens SIMATIC STEP 7 V5 Version: All versions < V5.6 SP2 HF3
Siemens SIMATIC WinCC OA V3.16 Version: All versions < V3.16 P018
Siemens SIMATIC WinCC OA V3.17 Version: All versions < V3.17 P003
Siemens SIMATIC WinCC Runtime Advanced Version: All versions < V16 Update 2
Siemens SIMATIC WinCC Runtime Professional V13 Version: All versions < V13 SP2 Update 4
Siemens SIMATIC WinCC Runtime Professional V14 Version: All versions < V14 SP1 Update 10
Siemens SIMATIC WinCC Runtime Professional V15 Version: All versions < V15.1 Update 5
Siemens SIMATIC WinCC Runtime Professional V16 Version: All versions < V16 Update 2
Siemens SIMATIC WinCC V7.4 Version: All versions < V7.4 SP1 Update 14
Siemens SIMATIC WinCC V7.5 Version: All versions < V7.5 SP1 Update 3
Siemens SINAMICS STARTER Version: All Versions < V5.4 HF2
Siemens SINAMICS Startdrive Version: All Versions < V16 Update 3
Siemens SINEC NMS Version: All versions < V1.0 SP2
Siemens SINEMA Server Version: All versions < V14 SP3
Siemens SINUMERIK ONE virtual Version: All Versions < V6.14
Siemens SINUMERIK Operate Version: All Versions < V6.14
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:33:19.492Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC Automation Tool",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4 SP2"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC Software V14",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Update 14"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC Software V15",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC Software V16",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16 Upd3"
            }
          ]
        },
        {
          "product": "SIMATIC PCS neo",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0 SP1"
            }
          ]
        },
        {
          "product": "SIMATIC ProSave",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V17"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.8"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 (TIA Portal) V13",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13 SP2 Update 4"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 (TIA Portal) V14",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Update 10"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 (TIA Portal) V15",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Update 5"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 (TIA Portal) V16",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16 Update 2"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 V5",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.6 SP2 HF3"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC OA V3.16",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.16 P018"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC OA V3.17",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.17 P003"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16 Update 2"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V13",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13 SP2 Update 4"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V14",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Update 10"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V15",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Update 5"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V16",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16 Update 2"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.4 SP1 Update 14"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.5",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.5 SP1 Update 3"
            }
          ]
        },
        {
          "product": "SINAMICS STARTER",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.4 HF2"
            }
          ]
        },
        {
          "product": "SINAMICS Startdrive",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V16 Update 3"
            }
          ]
        },
        {
          "product": "SINEC NMS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0 SP2"
            }
          ]
        },
        {
          "product": "SINEMA Server",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP3"
            }
          ]
        },
        {
          "product": "SINUMERIK ONE virtual",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V6.14"
            }
          ]
        },
        {
          "product": "SINUMERIK Operate",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V6.14"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Automation Tool (All versions \u003c V4 SP2), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Upd3), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC ProSave (All versions \u003c V17), SIMATIC S7-1500 Software Controller (All versions \u003c V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMATIC STEP 7 V5 (All versions \u003c V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions \u003c V3.16 P018), SIMATIC WinCC OA V3.17 (All versions \u003c V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions \u003c V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 3), SINAMICS STARTER (All Versions \u003c V5.4 HF2), SINAMICS Startdrive (All Versions \u003c V16 Update 3), SINEC NMS (All versions \u003c V1.0 SP2), SINEMA Server (All versions \u003c V14 SP3), SINUMERIK ONE virtual (All Versions \u003c V6.14), SINUMERIK Operate (All Versions \u003c V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-428",
              "description": "CWE-428: Unquoted Search Path or Element",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-13T00:00:00",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf"
        },
        {
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-7580",
    "datePublished": "2020-06-10T00:00:00",
    "dateReserved": "2020-01-21T00:00:00",
    "dateUpdated": "2024-08-04T09:33:19.492Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2018-4832
Vulnerability from cvelistv5
Published
2018-04-24 17:00
Modified
2024-08-05 05:18
Severity ?
Summary
A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions < V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions < V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions < V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions < V8.2 Upd10), SIMATIC BATCH V9.0 (All versions < V9.0 SP1), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions < 15 SP1), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Upd5), SIMATIC WinCC V7.2 and earlier (All versions < WinCC 7.2 Upd 15), SIMATIC WinCC V7.3 (All versions < WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 4), SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
Impacted products
Vendor Product Version
Siemens OpenPCS 7 V8.0 Version: All versions
Siemens OpenPCS 7 V8.1 Version: All versions < V8.1 Upd5
Siemens OpenPCS 7 V8.2 Version: All versions
Siemens OpenPCS 7 V9.0 Version: All versions < V9.0 Upd1
Siemens SIMATIC BATCH V7.1 and earlier Version: All versions
Siemens SIMATIC BATCH V8.0 Version: All versions < V8.0 SP1 Upd21
Siemens SIMATIC BATCH V8.1 Version: All versions < V8.1 SP1 Upd16
Siemens SIMATIC BATCH V8.2 Version: All versions < V8.2 Upd10
Siemens SIMATIC BATCH V9.0 Version: All versions < V9.0 SP1
Siemens SIMATIC NET PC Software V14 Version: All versions < V14 SP1 Update 14
Siemens SIMATIC NET PC Software V15 Version: All versions < 15 SP1
Siemens SIMATIC PCS 7 V7.1 and earlier Version: All versions
Siemens SIMATIC PCS 7 V8.0 Version: All versions
Siemens SIMATIC PCS 7 V8.1 Version: All versions
Siemens SIMATIC PCS 7 V8.2 Version: All versions < V8.2 SP1
Siemens SIMATIC PCS 7 V9.0 Version: All versions < V9.0 SP1
Siemens SIMATIC Route Control V7.1 and earlier Version: All versions
Siemens SIMATIC Route Control V8.0 Version: All versions
Siemens SIMATIC Route Control V8.1 Version: All versions
Siemens SIMATIC Route Control V8.2 Version: All versions
Siemens SIMATIC Route Control V9.0 Version: All versions < V9.0 Upd1
Siemens SIMATIC WinCC Runtime Professional V13 Version: All versions < V13 SP2 Upd2
Siemens SIMATIC WinCC Runtime Professional V14 Version: All versions < V14 SP1 Upd5
Siemens SIMATIC WinCC V7.2 and earlier Version: All versions < WinCC 7.2 Upd 15
Siemens SIMATIC WinCC V7.3 Version: All versions < WinCC 7.3 Upd 16
Siemens SIMATIC WinCC V7.4 Version: All versions < V7.4 SP1 Upd 4
Siemens SPPA-T3000 Application Server Version: All versions < Service Pack R8.2 SP2
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T05:18:26.633Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "OpenPCS 7 V7.1 and earlier",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "OpenPCS 7 V8.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "OpenPCS 7 V8.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.1 Upd5"
            }
          ]
        },
        {
          "product": "OpenPCS 7 V8.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "OpenPCS 7 V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 Upd1"
            }
          ]
        },
        {
          "product": "SIMATIC BATCH V7.1 and earlier",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC BATCH V8.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.0 SP1 Upd21"
            }
          ]
        },
        {
          "product": "SIMATIC BATCH V8.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.1 SP1 Upd16"
            }
          ]
        },
        {
          "product": "SIMATIC BATCH V8.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.2 Upd10"
            }
          ]
        },
        {
          "product": "SIMATIC BATCH V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 SP1"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC Software V14",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Update 14"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC Software V15",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c 15 SP1"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V7.1 and earlier",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V8.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V8.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V8.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.2 SP1"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 SP1"
            }
          ]
        },
        {
          "product": "SIMATIC Route Control V7.1 and earlier",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC Route Control V8.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC Route Control V8.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC Route Control V8.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC Route Control V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 Upd1"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V13",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13 SP2 Upd2"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V14",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Upd5"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.2 and earlier",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c WinCC 7.2 Upd 15"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c WinCC 7.3 Upd 16"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.4 SP1 Upd 4"
            }
          ]
        },
        {
          "product": "SPPA-T3000 Application Server",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c Service Pack R8.2 SP2"
            }
          ]
        }
      ],
      "datePublic": "2018-03-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions \u003c V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions \u003c V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions \u003c V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions \u003c V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions \u003c V8.2 Upd10), SIMATIC BATCH V9.0 (All versions \u003c V9.0 SP1), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions \u003c 15 SP1), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions \u003c V9.0 Upd1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Upd5), SIMATIC WinCC V7.2 and earlier (All versions \u003c WinCC 7.2 Upd 15), SIMATIC WinCC V7.3 (All versions \u003c WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 4), SPPA-T3000 Application Server (All versions \u003c Service Pack R8.2 SP2). Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20: Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-12T09:06:48",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2018-4832",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "OpenPCS 7 V7.1 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "OpenPCS 7 V8.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "OpenPCS 7 V8.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.1 Upd5"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "OpenPCS 7 V8.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "OpenPCS 7 V9.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.0 Upd1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC BATCH V7.1 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC BATCH V8.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.0 SP1 Upd21"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC BATCH V8.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.1 SP1 Upd16"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC BATCH V8.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.2 Upd10"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC BATCH V9.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.0 SP1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC NET PC Software V14",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14 SP1 Update 14"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC NET PC Software V15",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c 15 SP1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V7.1 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V8.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V8.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V8.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.2 SP1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V9.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.0 SP1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC Route Control V7.1 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC Route Control V8.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC Route Control V8.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC Route Control V8.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC Route Control V9.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.0 Upd1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V13",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13 SP2 Upd2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V14",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14 SP1 Upd5"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.2 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c WinCC 7.2 Upd 15"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c WinCC 7.3 Upd 16"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.4",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.4 SP1 Upd 4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SPPA-T3000 Application Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c Service Pack R8.2 SP2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions \u003c V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions \u003c V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions \u003c V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions \u003c V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions \u003c V8.2 Upd10), SIMATIC BATCH V9.0 (All versions \u003c V9.0 SP1), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions \u003c 15 SP1), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions \u003c V9.0 Upd1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Upd5), SIMATIC WinCC V7.2 and earlier (All versions \u003c WinCC 7.2 Upd 15), SIMATIC WinCC V7.3 (All versions \u003c WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 4), SPPA-T3000 Application Server (All versions \u003c Service Pack R8.2 SP2). Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-20: Improper Input Validation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf"
            },
            {
              "name": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html",
              "refsource": "MISC",
              "url": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2018-4832",
    "datePublished": "2018-04-24T17:00:00",
    "dateReserved": "2018-01-02T00:00:00",
    "dateUpdated": "2024-08-05T05:18:26.633Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}