All the vulnerabilites related to Siemens - SIMATIC WinCC Runtime Advanced
cve-2023-46280
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2023-46280", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-05-29T14:20:28.448026Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:22:08.819Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T20:37:40.324Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-962515.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Security Configuration Tool (SCT)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Automation Tool", "vendor": "Siemens", "versions": [ { "lessThan": "V5.0 SP2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC BATCH V9.1", "vendor": "Siemens", "versions": [ { "lessThan": "V9.1 SP2 Upd5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V16", "vendor": "Siemens", "versions": [ { "lessThan": "V16 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V17", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V19", "vendor": "Siemens", "versions": [ { "lessThan": "V19 Update 2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V9.1", "vendor": "Siemens", "versions": [ { "lessThan": "V9.1 SP2 UC05", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PDM V9.2", "vendor": "Siemens", "versions": [ { "lessThan": "V9.2 SP2 Upd3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Route Control V9.1", "vendor": "Siemens", "versions": [ { "lessThan": "V9.1 SP2 Upd3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-PCT", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5 SP3 Update 6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC STEP 7 V5", "vendor": "Siemens", "versions": [ { "lessThan": "V5.7 SP3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC OA V3.17", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC OA V3.18", "vendor": "Siemens", "versions": [ { "lessThan": "V3.18 P025", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC OA V3.19", "vendor": "Siemens", "versions": [ { "lessThan": "V3.19 P010", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V16", "vendor": "Siemens", "versions": [ { "lessThan": "V16 Update 6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V19", "vendor": "Siemens", "versions": [ { "lessThan": "V19 Update 2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.5", "vendor": "Siemens", "versions": [ { "lessThan": "V7.5 SP2 Update 17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V8.0", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0 Update 5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS Startdrive", "vendor": "Siemens", "versions": [ { "lessThan": "V19 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK ONE virtual", "vendor": "Siemens", "versions": [ { "lessThan": "V6.23", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK PLC Programming Tool", "vendor": "Siemens", "versions": [ { "lessThan": "V3.3.12", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "TIA Portal Cloud Connector", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V15.1", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V17", "vendor": "Siemens", "versions": [ { "lessThan": "V17 Update 8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Totally Integrated Automation Portal (TIA Portal) V19", "vendor": "Siemens", "versions": [ { "lessThan": "V19 Update 2", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions \u003c V5.0 SP2), SIMATIC BATCH V9.1 (All versions \u003c V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions \u003c V16 Update 8), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions \u003c V18 SP1), SIMATIC NET PC Software V19 (All versions \u003c V19 Update 2), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC PDM V9.2 (All versions \u003c V9.2 SP2 Upd3), SIMATIC Route Control V9.1 (All versions \u003c V9.1 SP2 Upd3), SIMATIC S7-PCT (All versions \u003c V3.5 SP3 Update 6), SIMATIC STEP 7 V5 (All versions \u003c V5.7 SP3), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions \u003c V3.18 P025), SIMATIC WinCC OA V3.19 (All versions \u003c V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions \u003c V17 Update 8), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions \u003c V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 5), SINAMICS Startdrive (All versions \u003c V19 SP1), SINEC NMS (All versions \u003c V3.0), SINEC NMS (All versions \u003c V3.0 SP1), SINUMERIK ONE virtual (All versions \u003c V6.23), SINUMERIK PLC Programming Tool (All versions \u003c V3.3.12), TIA Portal Cloud Connector (All versions \u003c V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions \u003c V19 Update 2). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 8.2, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-10T13:53:28.579Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-962515.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-784301.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-331112.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-46280", "datePublished": "2024-05-14T10:01:52.069Z", "dateReserved": "2023-10-20T08:02:52.794Z", "dateUpdated": "2024-12-10T13:53:28.579Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-6575
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf | x_refsource_MISC |
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC CP 443-1 OPC UA |
Version: All versions |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:23:22.041Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC CP 443-1 OPC UA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "product": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Upd 4" } ] }, { "product": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Upd 4" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Upd 4" } ] }, { "product": "SIMATIC IPC DiagMonitor", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1.3" } ] }, { "product": "SIMATIC NET PC Software V13", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC NET PC Software V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 14" } ] }, { "product": "SIMATIC NET PC Software V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC RF188C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.0" } ] }, { "product": "SIMATIC RF600R family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.1" } ] }, { "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.5 \u003c V2.6.1" } ] }, { "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions between V2.5 (including) and V2.7 (excluding)" } ] }, { "product": "SIMATIC WinCC OA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.15 P018" } ] }, { "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Upd 4" } ] }, { "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0 SP1" } ] }, { "product": "SINEMA Server", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP2" } ] }, { "product": "SINUMERIK OPC UA Server", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "product": "TeleControl Server Basic", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.1.1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V2.7), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions \u003c V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions \u003c V1.1.0), SIMATIC RF600R family (All versions \u003c V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.5 \u003c V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions \u003c V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Upd 4), SINEC NMS (All versions \u003c V1.0 SP1), SINEMA Server (All versions \u003c V14 SP2), SINUMERIK OPC UA Server (All versions \u003c V2.1), TeleControl Server Basic (All versions \u003c V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-248", "description": "CWE-248: Uncaught Exception", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-10T11:16:36", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-6575", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC CP 443-1 OPC UA", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.7" } ] } }, { "product_name": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Upd 4" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Upd 4" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Upd 4" } ] } }, { "product_name": "SIMATIC IPC DiagMonitor", "version": { "version_data": [ { "version_value": "All versions \u003c V5.1.3" } ] } }, { "product_name": "SIMATIC NET PC Software V13", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC NET PC Software V14", "version": { "version_data": [ { "version_value": "All versions \u003c V14 SP1 Update 14" } ] } }, { "product_name": "SIMATIC NET PC Software V15", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC RF188C", "version": { "version_data": [ { "version_value": "All versions \u003c V1.1.0" } ] } }, { "product_name": "SIMATIC RF600R family", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2.1" } ] } }, { "product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.5 \u003c V2.6.1" } ] } }, { "product_name": "SIMATIC S7-1500 Software Controller", "version": { "version_data": [ { "version_value": "All versions between V2.5 (including) and V2.7 (excluding)" } ] } }, { "product_name": "SIMATIC WinCC OA", "version": { "version_data": [ { "version_value": "All versions \u003c V3.15 P018" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Upd 4" } ] } }, { "product_name": "SINEC NMS", "version": { "version_data": [ { "version_value": "All versions \u003c V1.0 SP1" } ] } }, { "product_name": "SINEMA Server", "version": { "version_data": [ { "version_value": "All versions \u003c V14 SP2" } ] } }, { "product_name": "SINUMERIK OPC UA Server", "version": { "version_data": [ { "version_value": "All versions \u003c V2.1" } ] } }, { "product_name": "TeleControl Server Basic", "version": { "version_data": [ { "version_value": "All versions \u003c V3.1.1" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V2.7), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions \u003c V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions \u003c V1.1.0), SIMATIC RF600R family (All versions \u003c V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.5 \u003c V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions \u003c V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Upd 4), SINEC NMS (All versions \u003c V1.0 SP1), SINEMA Server (All versions \u003c V14 SP2), SINUMERIK OPC UA Server (All versions \u003c V2.1), TeleControl Server Basic (All versions \u003c V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-248: Uncaught Exception" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-6575", "datePublished": "2019-04-17T13:40:24", "dateReserved": "2019-01-22T00:00:00", "dateUpdated": "2024-08-04T20:23:22.041Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-30694
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC Drive Controller CPU 1504D TF |
Version: All versions < V2.9.7 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T06:56:13.567Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478960.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC Drive Controller CPU 1504D TF", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Drive Controller CPU 1507D TF", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM154-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM154-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM154-8FX PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V21.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PC Station", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.6.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1510SP F-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1510SP F-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1510SP-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1510SP-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511C-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511C-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511F-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511F-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511F-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511T-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1511TF-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1512C-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1512C-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1512SP F-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1512SP F-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1512SP-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1512SP-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1513-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1513-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1513-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1513F-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1513F-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1513F-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1513R-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515-2 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515-2 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515-2 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515F-2 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515F-2 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515F-2 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515R-2 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515T-2 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1515TF-2 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1516T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1516TF-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1517-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1517F-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1517H-3 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1517T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1517TF-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1518HF-4 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1518T-4 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU 1518TF-4 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller V2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V21.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319F-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-PLCSIM Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V17 Update 5" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK ONE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.22" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1510SP-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1510SP-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1512SP-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1512SP-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511F-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511F-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1511F-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1513-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1513-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1513-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1513-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1513-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1513F-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1513F-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1513F-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1515F-2 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1515F-2 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1515F-2 PN RAIL", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1515R-2 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.9.7" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1517H-3 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.1" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.1" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.1" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1518F-4 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.1" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-1500 CPU 1518HF-4 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.1" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] } ], "descriptions": [ { "lang": "en", "value": "The login endpoint /FormLogin in affected web services does not apply proper origin checking.\r\n\r\nThis could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-352", "description": "CWE-352: Cross-Site Request Forgery (CSRF)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-09-12T09:31:58.151Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478960.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-30694", "datePublished": "2022-11-08T00:00:00", "dateReserved": "2022-05-13T00:00:00", "dateUpdated": "2024-08-03T06:56:13.567Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-10929
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf | x_refsource_MISC | |
https://www.us-cert.gov/ics/advisories/icsa-19-344-04 | x_refsource_MISC |
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC CP 1626 |
Version: All versions |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T22:40:15.230Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC CP 1626", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V20.8" } ] }, { "product": "SIMATIC HMI Panel (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC NET PC Software V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 14" } ] }, { "product": "SIMATIC NET PC Software V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4.0" } ] }, { "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.1" } ] }, { "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V20.8" } ] }, { "product": "SIMATIC S7-PLCSIM Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16" } ] }, { "product": "SIMATIC WinCC (TIA Portal)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16" } ] }, { "product": "SIMATIC WinCC OA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.16 P013" } ] }, { "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16" } ] }, { "product": "SIMATIC WinCC Runtime Professional", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16" } ] }, { "product": "TIM 1531 IRC (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC STEP 7 (TIA Portal) (All versions \u003c V16), SIMATIC WinCC (TIA Portal) (All versions \u003c V16), SIMATIC WinCC OA (All versions \u003c V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions \u003c V16), SIMATIC WinCC Runtime Professional (All versions \u003c V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions \u003c V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-327", "description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-10T11:16:07", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-10929", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC CP 1626", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V20.8" } ] } }, { "product_name": "SIMATIC HMI Panel (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC NET PC Software V14", "version": { "version_data": [ { "version_value": "All versions \u003c V14 SP1 Update 14" } ] } }, { "product_name": "SIMATIC NET PC Software V15", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.4.0" } ] } }, { "product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.8.1" } ] } }, { "product_name": "SIMATIC S7-1500 Software Controller", "version": { "version_data": [ { "version_value": "All versions \u003c V20.8" } ] } }, { "product_name": "SIMATIC S7-PLCSIM Advanced", "version": { "version_data": [ { "version_value": "All versions \u003c V3.0" } ] } }, { "product_name": "SIMATIC STEP 7 (TIA Portal)", "version": { "version_data": [ { "version_value": "All versions \u003c V16" } ] } }, { "product_name": "SIMATIC WinCC (TIA Portal)", "version": { "version_data": [ { "version_value": "All versions \u003c V16" } ] } }, { "product_name": "SIMATIC WinCC OA", "version": { "version_data": [ { "version_value": "All versions \u003c V3.16 P013" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced", "version": { "version_data": [ { "version_value": "All versions \u003c V16" } ] } }, { "product_name": "SIMATIC WinCC Runtime Professional", "version": { "version_data": [ { "version_value": "All versions \u003c V16" } ] } }, { "product_name": "TIM 1531 IRC (incl. SIPLUS NET variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V2.1" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC STEP 7 (TIA Portal) (All versions \u003c V16), SIMATIC WinCC (TIA Portal) (All versions \u003c V16), SIMATIC WinCC OA (All versions \u003c V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions \u003c V16), SIMATIC WinCC Runtime Professional (All versions \u003c V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions \u003c V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-10929", "datePublished": "2019-08-13T18:55:57", "dateReserved": "2019-04-08T00:00:00", "dateUpdated": "2024-08-04T22:40:15.230Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-7580
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC Automation Tool |
Version: All versions < V4 SP2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T09:33:19.492Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf" }, { "tags": [ "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC Automation Tool", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4 SP2" } ] }, { "product": "SIMATIC NET PC Software V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 14" } ] }, { "product": "SIMATIC NET PC Software V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC NET PC Software V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Upd3" } ] }, { "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0 SP1" } ] }, { "product": "SIMATIC ProSave", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V17" } ] }, { "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V21.8" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V13", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13 SP2 Update 4" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 10" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 5" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 2" } ] }, { "product": "SIMATIC STEP 7 V5", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.6 SP2 HF3" } ] }, { "product": "SIMATIC WinCC OA V3.16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.16 P018" } ] }, { "product": "SIMATIC WinCC OA V3.17", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.17 P003" } ] }, { "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 2" } ] }, { "product": "SIMATIC WinCC Runtime Professional V13", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13 SP2 Update 4" } ] }, { "product": "SIMATIC WinCC Runtime Professional V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 10" } ] }, { "product": "SIMATIC WinCC Runtime Professional V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 5" } ] }, { "product": "SIMATIC WinCC Runtime Professional V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 2" } ] }, { "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.4 SP1 Update 14" } ] }, { "product": "SIMATIC WinCC V7.5", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.5 SP1 Update 3" } ] }, { "product": "SINAMICS STARTER", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.4 HF2" } ] }, { "product": "SINAMICS Startdrive", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V16 Update 3" } ] }, { "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0 SP2" } ] }, { "product": "SINEMA Server", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP3" } ] }, { "product": "SINUMERIK ONE virtual", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V6.14" } ] }, { "product": "SINUMERIK Operate", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V6.14" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC Automation Tool (All versions \u003c V4 SP2), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Upd3), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC ProSave (All versions \u003c V17), SIMATIC S7-1500 Software Controller (All versions \u003c V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMATIC STEP 7 V5 (All versions \u003c V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions \u003c V3.16 P018), SIMATIC WinCC OA V3.17 (All versions \u003c V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions \u003c V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 3), SINAMICS STARTER (All Versions \u003c V5.4 HF2), SINAMICS Startdrive (All Versions \u003c V16 Update 3), SINEC NMS (All versions \u003c V1.0 SP2), SINEMA Server (All versions \u003c V14 SP3), SINUMERIK ONE virtual (All Versions \u003c V6.14), SINUMERIK Operate (All Versions \u003c V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-428", "description": "CWE-428: Unquoted Search Path or Element", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-13T00:00:00", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf" }, { "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-7580", "datePublished": "2020-06-10T00:00:00", "dateReserved": "2020-01-21T00:00:00", "dateUpdated": "2024-08-04T09:33:19.492Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-30755
Vulnerability from cvelistv5
5.9 (Medium) - CVSS:4.0/AV:N/AC:H/AT:N/PR:H/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) |
Version: 0 < V3.5.20 |
||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2023-30755", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-09-10T15:10:26.969445Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-10T15:10:35.515Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-7 LTE", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-8 IRC", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC IPC DiagBase", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC IPC DiagMonitor", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS TIM 1531 IRC", "vendor": "Siemens", "versions": [ { "lessThan": "V2.4.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "TIM 1531 IRC", "vendor": "Siemens", "versions": [ { "lessThan": "V2.4.8", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-7 LTE (All versions \u003c V3.5.20), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.5.20), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC WinCC Runtime Advanced (All versions), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.4.8). The web server of the affected devices do not properly handle the shutdown or reboot request, which could lead to the clean up of certain resources. \r\n\r\nThis could allow a remote attacker with elevated privileges to cause a denial of service condition in the system." } ], "metrics": [ { "cvssV3_1": { "baseScore": 4.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:H/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-476", "description": "CWE-476: NULL Pointer Dereference", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:33:39.215Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-423808.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-30755", "datePublished": "2024-09-10T09:33:39.215Z", "dateReserved": "2023-04-14T11:16:56.497Z", "dateUpdated": "2024-09-10T15:10:35.515Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-30756
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) |
Version: 0 < V3.5.20 |
||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2023-30756", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-09-10T15:09:52.396615Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-10T15:10:00.273Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-7 LTE", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-8 IRC", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC IPC DiagBase", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC IPC DiagMonitor", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS TIM 1531 IRC", "vendor": "Siemens", "versions": [ { "lessThan": "V2.4.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "TIM 1531 IRC", "vendor": "Siemens", "versions": [ { "lessThan": "V2.4.8", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-7 LTE (All versions \u003c V3.5.20), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.5.20), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC WinCC Runtime Advanced (All versions), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.4.8). The web server of the affected devices do not properly handle certain errors when using the Expect HTTP request header, resulting in NULL dereference.\r\n\r\nThis could allow a remote attacker with no privileges to cause a denial of service condition in the system." } ], "metrics": [ { "cvssV3_1": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 8.2, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-476", "description": "CWE-476: NULL Pointer Dereference", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:33:40.640Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-423808.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-30756", "datePublished": "2024-09-10T09:33:40.640Z", "dateReserved": "2023-04-14T11:16:56.497Z", "dateUpdated": "2024-09-10T15:10:00.273Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-28827
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) |
Version: 0 < V3.5.20 |
||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2023-28827", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-09-10T15:10:54.020229Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-10T15:11:03.085Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-7 LTE", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-8 IRC", "vendor": "Siemens", "versions": [ { "lessThan": "V3.5.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC IPC DiagBase", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC IPC DiagMonitor", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS TIM 1531 IRC", "vendor": "Siemens", "versions": [ { "lessThan": "V2.4.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "TIM 1531 IRC", "vendor": "Siemens", "versions": [ { "lessThan": "V2.4.8", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-7 LTE (All versions \u003c V3.5.20), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.5.20), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC WinCC Runtime Advanced (All versions), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.4.8). The web server of the affected devices do not properly handle certain requests, causing a timeout in the watchdog, which could lead to the clean up of pointers. \r\n\r\nThis could allow a remote attacker to cause a denial of service condition in the system." } ], "metrics": [ { "cvssV3_1": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 8.2, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-476", "description": "CWE-476: NULL Pointer Dereference", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:33:37.794Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-423808.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-28827", "datePublished": "2024-09-10T09:33:37.794Z", "dateReserved": "2023-03-24T15:17:29.557Z", "dateUpdated": "2024-09-10T15:11:03.085Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-6568
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC CP 1604 |
Version: All versions |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:23:22.207Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC CP 1604", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1616", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 OPC UA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM154-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM154-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM154-8FX PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.6" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Upd4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Upd4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Upd4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC IPC DiagMonitor", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF182C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF185C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF186C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF188C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF600R family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RFID 181EIP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.6.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319F-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-PLCSIM Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0 SP1 UPD1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Basic", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Standard", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX F 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Upd4" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.6 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.7 SP1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.8 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF6" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V5.1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V5.1 SP1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 SP1 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.6 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.7 SP1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.8 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF6" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V5.1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V5.1 SP1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 SP1 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GH150 V4.7 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GH150 V4.8 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2 HF9" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GL150 V4.7 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GL150 V4.8 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2 HF9" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GM150 V4.7 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GM150 V4.8 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2 HF9" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.6 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 SP1 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.8 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF6" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V5.1 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V5.1 SP1 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 SP1 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.6 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.7 SP1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.8 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF6" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V5.1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V5.1 SP1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 SP1 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S210", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 SP1 HF8" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF33" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.8 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SM120 V4.7 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SM120 V4.8 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2 HF10" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SM150 V4.8 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET CP 343-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET CP 443-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET CP 443-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SITOP Manager", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1" } ] }, { "defaultStatus": "unknown", "product": "SITOP PSU8600", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.5" } ] }, { "defaultStatus": "unknown", "product": "SITOP UPS1600 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "TIM 1531 IRC (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] } ], "descriptions": [ { "lang": "en", "value": "The webserver of the affected devices contains a vulnerability that may lead to\r\na denial of service condition. An attacker may cause a denial of service\r\nsituation which leads to a restart of the webserver of the affected device.\r\n\r\nThe security vulnerability could be exploited by an attacker with network\r\naccess to the affected systems. Successful exploitation requires no system\r\nprivileges and no user interaction. An attacker could use the vulnerability\r\nto compromise availability of the device." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-05-09T11:51:03.049Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-6568", "datePublished": "2019-04-17T13:40:24", "dateReserved": "2019-01-22T00:00:00", "dateUpdated": "2024-08-04T20:23:22.207Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
var-202105-0789
Vulnerability from variot
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition. Multiple Siemens products contain buffer error vulnerabilities.Denial of service (DoS) It may be put into a state. Siemens SmartVNC is an industrial control equipment of Germany's Siemens (Siemens) company. Provides a function to access the smartserver in the HMI.
Siemens SmartVNC has security vulnerabilities. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202105-0789", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic wincc runtime advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic wincc runtime advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi comfort outdoor panels 7\"", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi comfort outdoor panels 15\"", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi comfort panels 4\"", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi comfort panels 22\"", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic wincc runtime advanced update", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v164" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-41246" }, { "db": "JVNDB", "id": "JVNDB-2021-006947" }, { "db": "NVD", "id": "CVE-2021-25660" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-542" } ], "trust": 0.6 }, "cve": "CVE-2021-25660", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2021-25660", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2021-41246", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2021-25660", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-25660", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-25660", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2021-25660", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-41246", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202105-542", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-25660", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-41246" }, { "db": "VULMON", "id": "CVE-2021-25660" }, { "db": "JVNDB", "id": "JVNDB-2021-006947" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-542" }, { "db": "NVD", "id": "CVE-2021-25660" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition. Multiple Siemens products contain buffer error vulnerabilities.Denial of service (DoS) It may be put into a state. Siemens SmartVNC is an industrial control equipment of Germany\u0027s Siemens (Siemens) company. Provides a function to access the smartserver in the HMI. \n\r\n\r\nSiemens SmartVNC has security vulnerabilities. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements", "sources": [ { "db": "NVD", "id": "CVE-2021-25660" }, { "db": "JVNDB", "id": "JVNDB-2021-006947" }, { "db": "CNVD", "id": "CNVD-2021-41246" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULMON", "id": "CVE-2021-25660" } ], "trust": 2.79 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-25660", "trust": 3.9 }, { "db": "SIEMENS", "id": "SSA-538778", "trust": 2.3 }, { "db": "JVN", "id": "JVNVU91051134", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-006947", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-41246", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021051206", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-21-131-12", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202105-542", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-25660", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-41246" }, { "db": "VULMON", "id": "CVE-2021-25660" }, { "db": "JVNDB", "id": "JVNDB-2021-006947" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-542" }, { "db": "NVD", "id": "CVE-2021-25660" } ] }, "id": "VAR-202105-0789", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-41246" } ], "trust": 1.12202686 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-41246" } ] }, "last_update_date": "2024-08-14T12:53:22.604000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-538778", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "title": "Patch for Siemens SmartVNC out-of-bounds memory access vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/272626" }, { "title": "Siemens SmartVNC Buffer error vulnerability fix", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=151557" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=9465a8ef1f8c1b0042244cb02cfe271e" }, { "title": "CVE-2021-25660", "trust": 0.1, "url": "https://github.com/JamesGeee/CVE-2021-25660 " } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-41246" }, { "db": "VULMON", "id": "CVE-2021-25660" }, { "db": "JVNDB", "id": "JVNDB-2021-006947" }, { "db": "CNNVD", "id": "CNNVD-202105-542" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-788", "trust": 1.0 }, { "problemtype": "CWE-119", "trust": 1.0 }, { "problemtype": "Buffer error (CWE-119) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006947" }, { "db": "NVD", "id": "CVE-2021-25660" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-25660" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu91051134/" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021051206" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/smartvnc-multiple-vulnerabilities-35360" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/119.html" }, { "trust": 0.1, "url": "https://github.com/jamesgeee/cve-2021-25660" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://cert-portal.siemens.com/productcert/txt/ssa-538778.txt" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-41246" }, { "db": "VULMON", "id": "CVE-2021-25660" }, { "db": "JVNDB", "id": "JVNDB-2021-006947" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-542" }, { "db": "NVD", "id": "CVE-2021-25660" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-41246" }, { "db": "VULMON", "id": "CVE-2021-25660" }, { "db": "JVNDB", "id": "JVNDB-2021-006947" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-542" }, { "db": "NVD", "id": "CVE-2021-25660" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-13T00:00:00", "db": "CNVD", "id": "CNVD-2021-41246" }, { "date": "2021-05-12T00:00:00", "db": "VULMON", "id": "CVE-2021-25660" }, { "date": "2022-01-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-006947" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-05-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-542" }, { "date": "2021-05-12T14:15:11.253000", "db": "NVD", "id": "CVE-2021-25660" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-13T00:00:00", "db": "CNVD", "id": "CNVD-2021-41246" }, { "date": "2021-05-21T00:00:00", "db": "VULMON", "id": "CVE-2021-25660" }, { "date": "2022-01-26T07:30:00", "db": "JVNDB", "id": "JVNDB-2021-006947" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-10-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-542" }, { "date": "2021-12-16T18:27:03.980000", "db": "NVD", "id": "CVE-2021-25660" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-542" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Buffer error vulnerabilities in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006947" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-975" } ], "trust": 0.6 } }
var-201202-0162
Vulnerability from variot
Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute arbitrary code via vectors related to Unicode strings. Miniweb has a security vulnerability that allows an attacker to submit a specially crafted HTTP POST request to allow the server to access any illegal memory area while checking the extension of the requested file. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. HmiLoad has multiple security vulnerabilities that allow an attacker to stop a service or crash a service in multiple ways. Siemens SIMATIC is an automation software in a single engineering environment. A security vulnerability exists in the Siemens SIMATIC WinCC HMI web server. When the transfer mode is enabled, the runtime loader listens on the 2308/TCP or 50523/TCP port. Without the correct data segment length and Unicode string, a stack overflow can be triggered, causing arbitrary code execution. A directory traversal vulnerability exists in the HmiLoad server that allows reading, writing, and deleting arbitrary files outside of the specified directory. Attackers can exploit these issues to execute arbitrary code in the context of the affected application, read/write or delete arbitrary files outside of the server root directory, or cause denial-of-service conditions; other attacks may also be possible
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0162", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic wincc flexible runtime", "scope": null, "trust": 3.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc flexible sp2", "scope": "eq", "trust": 3.3, "vendor": "siemens", "version": "2008" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "mp" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "op" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "tp" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2007" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2005" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2004" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "2008" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "comfort_panels" }, { "model": "wincc runtime advanced", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "v11" }, { "model": "wincc", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "v11" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "mobile_panels" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "2007" }, { "model": "simatic wincc", "scope": "eq", "trust": 1.4, "vendor": "siemens", "version": "v11" }, { "model": "simatic wincc flexible runtime", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic wincc flexible sp2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2008*" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2004" }, { "model": "wincc flexible runtime", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2005" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "comfort panels" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "mobile panels" }, { "model": "simatic wincc flexible rumtime", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "v11" }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic hmi panels", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "wincc flexible runtime", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc flexible runtime", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc flexible sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc flexible sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2005" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2004" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2005" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2007" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2008" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc", "version": "v11" }, { "model": "comfort panels", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "mobile panels", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "mp", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "op", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "tp", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc runtime advanced", "version": "v11" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible runtime", "version": "*" } ], "sources": [ { "db": "IVD", "id": "61050c40-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "5e37bfa8-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "9fe8f34a-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "28c3f672-2354-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "9c31ed38-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "9ef7b7be-1f7d-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2012-0465" }, { "db": "CNVD", "id": "CNVD-2011-5105" }, { "db": "BID", "id": "50828" }, { "db": "JVNDB", "id": "JVNDB-2012-001317" }, { "db": "CNNVD", "id": "CNNVD-201202-090" }, { "db": "NVD", "id": "CVE-2011-4875" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:siemens:simatic_hmi_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_flexible", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_flexible_runtime", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2012-001317" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Luigi Auriemma", "sources": [ { "db": "BID", "id": "50828" }, { "db": "CNNVD", "id": "CNNVD-201111-480" } ], "trust": 0.9 }, "cve": "CVE-2011-4875", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.6, "id": "CVE-2011-4875", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.6, "id": "61050c40-1f7d-11e6-abef-000c29c66e3d", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.6, "id": "5e37bfa8-1f7d-11e6-abef-000c29c66e3d", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.6, "id": "9fe8f34a-1f7d-11e6-abef-000c29c66e3d", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.6, "id": "28c3f672-2354-11e6-abef-000c29c66e3d", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.6, "id": "9c31ed38-1f7d-11e6-abef-000c29c66e3d", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.6, "id": "9ef7b7be-1f7d-11e6-abef-000c29c66e3d", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.6, "id": "VHN-52820", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:M/AU:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2011-4875", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2011-4875", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-201202-090", "trust": 0.6, "value": "CRITICAL" }, { "author": "IVD", "id": "61050c40-1f7d-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "CRITICAL" }, { "author": "IVD", "id": "5e37bfa8-1f7d-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "CRITICAL" }, { "author": "IVD", "id": "9fe8f34a-1f7d-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "CRITICAL" }, { "author": "IVD", "id": "28c3f672-2354-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "CRITICAL" }, { "author": "IVD", "id": "9c31ed38-1f7d-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "CRITICAL" }, { "author": "IVD", "id": "9ef7b7be-1f7d-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "CRITICAL" }, { "author": "VULHUB", "id": "VHN-52820", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "IVD", "id": "61050c40-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "5e37bfa8-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "9fe8f34a-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "28c3f672-2354-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "9c31ed38-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "9ef7b7be-1f7d-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-52820" }, { "db": "JVNDB", "id": "JVNDB-2012-001317" }, { "db": "CNNVD", "id": "CNNVD-201202-090" }, { "db": "NVD", "id": "CVE-2011-4875" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute arbitrary code via vectors related to Unicode strings. Miniweb has a security vulnerability that allows an attacker to submit a specially crafted HTTP POST request to allow the server to access any illegal memory area while checking the extension of the requested file. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. HmiLoad has multiple security vulnerabilities that allow an attacker to stop a service or crash a service in multiple ways. Siemens SIMATIC is an automation software in a single engineering environment. A security vulnerability exists in the Siemens SIMATIC WinCC HMI web server. When the transfer mode is enabled, the runtime loader listens on the 2308/TCP or 50523/TCP port. Without the correct data segment length and Unicode string, a stack overflow can be triggered, causing arbitrary code execution. A directory traversal vulnerability exists in the HmiLoad server that allows reading, writing, and deleting arbitrary files outside of the specified directory. \nAttackers can exploit these issues to execute arbitrary code in the context of the affected application, read/write or delete arbitrary files outside of the server root directory, or cause denial-of-service conditions; other attacks may also be possible", "sources": [ { "db": "NVD", "id": "CVE-2011-4875" }, { "db": "JVNDB", "id": "JVNDB-2012-001317" }, { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2012-0465" }, { "db": "CNVD", "id": "CNVD-2011-5105" }, { "db": "BID", "id": "50828" }, { "db": "IVD", "id": "61050c40-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "5e37bfa8-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "9fe8f34a-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "28c3f672-2354-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "9c31ed38-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "9ef7b7be-1f7d-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-52820" } ], "trust": 6.3 }, "exploit_availability": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/exploit_availability#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "reference": "https://www.scap.org.cn/vuln/vhn-52820", "trust": 0.1, "type": "unknown" } ], "sources": [ { "db": "VULHUB", "id": "VHN-52820" } ] }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2011-4875", "trust": 4.6 }, { "db": "BID", "id": "50828", "trust": 3.9 }, { "db": "ICS CERT", "id": "ICSA-12-030-01", "trust": 3.4 }, { "db": "CNNVD", "id": "CNNVD-201202-090", "trust": 1.9 }, { "db": "SIEMENS", "id": "SSA-345442", "trust": 1.7 }, { "db": "ICS CERT ALERT", "id": "ICS-ALERT-11-332-02A", "trust": 1.1 }, { "db": "ICS CERT ALERT", "id": "ICS-ALERT-11-332-02", "trust": 1.1 }, { "db": "EXPLOIT-DB", "id": "18166", "trust": 1.1 }, { "db": "OSVDB", "id": "77380", "trust": 1.1 }, { "db": "CNVD", "id": "CNVD-2011-5103", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2011-5105", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2011-5107", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2012-0465", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2011-5110", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2011-5108", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2012-001317", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201111-480", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-12-030-01A", "trust": 0.3 }, { "db": "IVD", "id": "61050C40-1F7D-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "IVD", "id": "5E37BFA8-1F7D-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "IVD", "id": "9FE8F34A-1F7D-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "IVD", "id": "28C3F672-2354-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "IVD", "id": "9C31ED38-1F7D-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "IVD", "id": "9EF7B7BE-1F7D-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "SEEBUG", "id": "SSVID-72366", "trust": 0.1 }, { "db": "VULHUB", "id": "VHN-52820", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "61050c40-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "5e37bfa8-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "9fe8f34a-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "28c3f672-2354-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "9c31ed38-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "9ef7b7be-1f7d-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2012-0465" }, { "db": "CNVD", "id": "CNVD-2011-5105" }, { "db": "VULHUB", "id": "VHN-52820" }, { "db": "BID", "id": "50828" }, { "db": "JVNDB", "id": "JVNDB-2012-001317" }, { "db": "CNNVD", "id": "CNNVD-201111-480" }, { "db": "CNNVD", "id": "CNNVD-201202-090" }, { "db": "NVD", "id": "CVE-2011-4875" } ] }, "id": "VAR-201202-0162", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "61050c40-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "5e37bfa8-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "9fe8f34a-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "28c3f672-2354-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "9c31ed38-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "9ef7b7be-1f7d-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2012-0465" }, { "db": "CNVD", "id": "CNVD-2011-5105" }, { "db": "VULHUB", "id": "VHN-52820" } ], "trust": 5.568457485714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 4.8 } ], "sources": [ { "db": "IVD", "id": "61050c40-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "5e37bfa8-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "9fe8f34a-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "28c3f672-2354-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "9c31ed38-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "9ef7b7be-1f7d-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2012-0465" }, { "db": "CNVD", "id": "CNVD-2011-5105" } ] }, "last_update_date": "2024-11-23T21:46:29.616000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-345442", "trust": 0.8, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "title": "\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc", "trust": 0.8, "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx" }, { "title": "Top Page", "trust": 0.8, "url": "http://www.siemens.com/entry/jp/ja/" }, { "title": "Patch for Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 file download vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/72694" }, { "title": "Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 memory access vulnerability patch", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/72697" }, { "title": "Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 Buffer Overflow Vulnerability Patch", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/72705" }, { "title": "Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 service crash vulnerability patch", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/72689" }, { "title": "Patch for Siemens SIMATIC WinCC HMI String Stack Overflow Vulnerability (CNVD-2012-0465)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/9071" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2012-0465" }, { "db": "JVNDB", "id": "JVNDB-2012-001317" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-119", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-52820" }, { "db": "JVNDB", "id": "JVNDB-2012-001317" }, { "db": "NVD", "id": "CVE-2011-4875" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.9, "url": "http://aluigi.altervista.org/adv/winccflex_1-adv.txt" }, { "trust": 3.4, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01.pdf" }, { "trust": 1.7, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "trust": 1.1, "url": "http://www.exploit-db.com/exploits/18166" }, { "trust": 1.1, "url": "http://aluigi.org/adv/winccflex_1-adv.txt" }, { "trust": 1.1, "url": "http://www.us-cert.gov/control_systems/pdf/ics-alert-11-332-02.pdf" }, { "trust": 1.1, "url": "http://www.us-cert.gov/control_systems/pdf/ics-alert-11-332-02a.pdf" }, { "trust": 1.1, "url": "http://www.osvdb.org/77380" }, { "trust": 1.1, "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71449" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4875" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4875" }, { "trust": 0.6, "url": "http://www.securityfocus.com/bid/50828" }, { "trust": 0.3, "url": "http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/wincc-flexible/wincc-flexible-runtime/pages/default.aspx" }, { "trust": 0.3, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01a.pdf" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2012-0465" }, { "db": "CNVD", "id": "CNVD-2011-5105" }, { "db": "VULHUB", "id": "VHN-52820" }, { "db": "BID", "id": "50828" }, { "db": "JVNDB", "id": "JVNDB-2012-001317" }, { "db": "CNNVD", "id": "CNNVD-201111-480" }, { "db": "CNNVD", "id": "CNNVD-201202-090" }, { "db": "NVD", "id": "CVE-2011-4875" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "61050c40-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "5e37bfa8-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "9fe8f34a-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "28c3f672-2354-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "9c31ed38-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "9ef7b7be-1f7d-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2012-0465" }, { "db": "CNVD", "id": "CNVD-2011-5105" }, { "db": "VULHUB", "id": "VHN-52820" }, { "db": "BID", "id": "50828" }, { "db": "JVNDB", "id": "JVNDB-2012-001317" }, { "db": "CNNVD", "id": "CNNVD-201111-480" }, { "db": "CNNVD", "id": "CNNVD-201202-090" }, { "db": "NVD", "id": "CVE-2011-4875" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2011-12-05T00:00:00", "db": "IVD", "id": "61050c40-1f7d-11e6-abef-000c29c66e3d" }, { "date": "2011-12-05T00:00:00", "db": "IVD", "id": "5e37bfa8-1f7d-11e6-abef-000c29c66e3d" }, { "date": "2011-12-05T00:00:00", "db": "IVD", "id": "9fe8f34a-1f7d-11e6-abef-000c29c66e3d" }, { "date": "2012-02-07T00:00:00", "db": "IVD", "id": "28c3f672-2354-11e6-abef-000c29c66e3d" }, { "date": "2011-12-05T00:00:00", "db": "IVD", "id": "9c31ed38-1f7d-11e6-abef-000c29c66e3d" }, { "date": "2011-12-05T00:00:00", "db": "IVD", "id": "9ef7b7be-1f7d-11e6-abef-000c29c66e3d" }, { "date": "2011-12-05T00:00:00", "db": "CNVD", "id": "CNVD-2011-5108" }, { "date": "2011-12-05T00:00:00", "db": "CNVD", "id": "CNVD-2011-5110" }, { "date": "2011-12-05T00:00:00", "db": "CNVD", "id": "CNVD-2011-5103" }, { "date": "2011-12-05T00:00:00", "db": "CNVD", "id": "CNVD-2011-5107" }, { "date": "2012-02-07T00:00:00", "db": "CNVD", "id": "CNVD-2012-0465" }, { "date": "2011-12-05T00:00:00", "db": "CNVD", "id": "CNVD-2011-5105" }, { "date": "2012-02-03T00:00:00", "db": "VULHUB", "id": "VHN-52820" }, { "date": "2011-11-28T00:00:00", "db": "BID", "id": "50828" }, { "date": "2012-02-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001317" }, { "date": "1900-01-01T00:00:00", "db": "CNNVD", "id": "CNNVD-201111-480" }, { "date": "2012-02-07T00:00:00", "db": "CNNVD", "id": "CNNVD-201202-090" }, { "date": "2012-02-03T20:55:01.907000", "db": "NVD", "id": "CVE-2011-4875" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2016-03-15T00:00:00", "db": "CNVD", "id": "CNVD-2011-5108" }, { "date": "2016-03-15T00:00:00", "db": "CNVD", "id": "CNVD-2011-5110" }, { "date": "2016-03-15T00:00:00", "db": "CNVD", "id": "CNVD-2011-5103" }, { "date": "2016-03-15T00:00:00", "db": "CNVD", "id": "CNVD-2011-5107" }, { "date": "2012-02-07T00:00:00", "db": "CNVD", "id": "CNVD-2012-0465" }, { "date": "2011-12-05T00:00:00", "db": "CNVD", "id": "CNVD-2011-5105" }, { "date": "2017-08-29T00:00:00", "db": "VULHUB", "id": "VHN-52820" }, { "date": "2012-04-18T21:20:00", "db": "BID", "id": "50828" }, { "date": "2012-02-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001317" }, { "date": "2011-11-30T00:00:00", "db": "CNNVD", "id": "CNNVD-201111-480" }, { "date": "2012-02-07T00:00:00", "db": "CNNVD", "id": "CNNVD-201202-090" }, { "date": "2024-11-21T01:33:10.353000", "db": "NVD", "id": "CVE-2011-4875" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201111-480" }, { "db": "CNNVD", "id": "CNNVD-201202-090" } ], "trust": 1.2 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 Buffer Overflow Vulnerability", "sources": [ { "db": "IVD", "id": "61050c40-1f7d-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5103" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Buffer overflow", "sources": [ { "db": "IVD", "id": "61050c40-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "5e37bfa8-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "9fe8f34a-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "28c3f672-2354-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "9c31ed38-1f7d-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "9ef7b7be-1f7d-11e6-abef-000c29c66e3d" }, { "db": "CNNVD", "id": "CNNVD-201202-090" } ], "trust": 1.8 } }
var-201202-0005
Vulnerability from variot
Buffer overflow in the Advantech ADAM OLE for Process Control (OPC) Server ActiveX control in ADAM OPC Server before 3.01.012, Modbus RTU OPC Server before 3.01.010, and Modbus TCP OPC Server before 3.01.010 allows remote attackers to execute arbitrary code via unspecified vectors. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. A memory corruption vulnerability exists in Siemens SIMATIC WinCC Flexible. Due to an unspecified error in the tag emulator, an attacker can cause memory corruption by opening a specially crafted file, and the exploit can successfully execute arbitrary code. Advantech ADAM OPC Server is a Taiwanese industrial device server interface. Advantech ADAM OPC Server is prone to a remote buffer-overflow vulnerability because it fails to sufficiently validate user-supplied data. This issue affects an unspecified ActiveX control. Failed exploit attempts will likely result in denial-of-service conditions. The following versions are affected: The following products are affected: ProTool 6.0 SP3 WinCC flexible 2004 WinCC flexible 2005 WinCC flexible 2005 SP1 WinCC flexible 2007 WinCC flexible 2008 WinCC flexible 2008 SP1 WinCC flexible 2008 SP2. The following products are affected: Siemens SIMATIC WinCC flexible Runtime Siemens SIMATIC WinCC (TIA Portal) Runtime Advanced. Successful exploitation of the vulnerability can execute arbitrary code. A failed attack may cause a denial of service.
The vulnerability are reported in versions 2005 SP1, 2007, 2008, 2008 SP1, and 2008 SP2. Please see vendor's advisory for details.
PROVIDED AND/OR DISCOVERED BY: Billy Rios and Terry McCorkle via ICS-CERT. ----------------------------------------------------------------------
Ovum says ad hoc tools are out-dated. The best practice approach? Fast vulnerability intelligence, threat handling, and setup in one tool.
Read the new report on the Secunia VIM: http://secunia.com/products/corporate/vim/ovum_2011_request/
TITLE: Advantech OPC Server ADAM ActiveX Control Buffer Overflow Vulnerability
SECUNIA ADVISORY ID: SA46775
VERIFY ADVISORY: Secunia.com http://secunia.com/advisories/46775/ Customer Area (Credentials Required) https://ca.secunia.com/?page=viewadvisory&vuln_id=46775
RELEASE DATE: 2011-11-07
DISCUSS ADVISORY: http://secunia.com/advisories/46775/#comments
AVAILABLE ON SITE AND IN CUSTOMER AREA: * Last Update * Popularity * Comments * Criticality Level * Impact * Where * Solution Status * Operating System / Software * CVE Reference(s)
http://secunia.com/advisories/46775/
ONLY AVAILABLE IN CUSTOMER AREA: * Authentication Level * Report Reliability * Secunia PoC * Secunia Analysis * Systems Affected * Approve Distribution * Remediation Status * Secunia CVSS Score * CVSS
https://ca.secunia.com/?page=viewadvisory&vuln_id=46775
ONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI: * AUTOMATED SCANNING
http://secunia.com/vulnerability_scanning/personal/ http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/
DESCRIPTION: A vulnerability has been reported in Advantech OPC Server, which can be exploited by malicious people to compromise a user's system.
The vulnerability is reported in the following components: * Advantech ADAM OPC Server versions prior to V3.01.012. * Advantech Modbus RTU OPC Server versions prior to V3.01.010. * Advantech Modbus TCP OPC Server versions prior to V3.01.010.
SOLUTION: Reportedly a patch has been released. Contact the vendor for further information.
PROVIDED AND/OR DISCOVERED BY: ICS-CERT credits Security Research and Service Institute Information and Communication Security Technology Center (ICST).
ORIGINAL ADVISORY: ICS-CERT: http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-01.pdf
OTHER REFERENCES: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
DEEP LINKS: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED DESCRIPTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED SOLUTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXPLOIT: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
About: This Advisory was delivered by Secunia as a free service to help private users keeping their systems up to date against the latest vulnerabilities.
Subscribe: http://secunia.com/advisories/secunia_security_advisories/
Definitions: (Criticality, Where etc.) http://secunia.com/advisories/about_secunia_advisories/
Please Note: Secunia recommends that you verify all advisories you receive by clicking the link. Secunia NEVER sends attached files with advisories. Secunia does not advise people to install third party patches, only use those supplied by the vendor.
Unsubscribe: Secunia Security Advisories http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org
Show details on source website
{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0005", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.1, "vendor": "siemens", "version": "2005" }, { "model": "modbus tcp opc server", "scope": "lte", "trust": 1.0, "vendor": "advantech", "version": "3.01.09" }, { "model": "modbus rtu opc server", "scope": "lte", "trust": 1.0, "vendor": "advantech", "version": "3.01.010" }, { "model": "adam opc server", "scope": "lte", "trust": 1.0, "vendor": "advantech", "version": "3.01.011" }, { "model": "protool sp3", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "6.0" }, { "model": "simatic wincc flexible sp2", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc flexible sp1", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "2007" }, { "model": "simatic wincc flexible sp1", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "2005" }, { "model": "adam opc server", "scope": "lt", "trust": 0.8, "vendor": "advantech", "version": "3.01.012" }, { "model": "modbus rtu opc server", "scope": "lt", "trust": 0.8, "vendor": "advantech", "version": "3.01.010" }, { "model": "modbus tcp opc server", "scope": "lt", "trust": 0.8, "vendor": "advantech", "version": "3.01.010" }, { "model": "modbus tcp opc server", "scope": null, "trust": 0.6, "vendor": "advantech", "version": null }, { "model": "modbus rtu opc server", "scope": null, "trust": 0.6, "vendor": "advantech", "version": null }, { "model": "adam opc server", "scope": null, "trust": 0.6, "vendor": "advantech", "version": null }, { "model": "modbus rtu opc server", "scope": "eq", "trust": 0.6, "vendor": "advantech", "version": "3.01.010" }, { "model": "modbus tcp opc server", "scope": "eq", "trust": 0.6, "vendor": "advantech", "version": "3.01.09" }, { "model": "adam opc server", "scope": "eq", "trust": 0.6, "vendor": "advantech", "version": "3.01.011" }, { "model": "modbus tcp opc server", "scope": "eq", "trust": 0.3, "vendor": "advantech", "version": "0" }, { "model": "modbus rtu opc server", "scope": "eq", "trust": 0.3, "vendor": "advantech", "version": "0" }, { "model": "adam opc server", "scope": "eq", "trust": 0.3, "vendor": "advantech", "version": "0" }, { "model": "modbus rtu opc server", "scope": "ne", "trust": 0.3, "vendor": "advantech", "version": "3.01.010" }, { "model": "modbus tcp opc server", "scope": "ne", "trust": 0.3, "vendor": "advantech", "version": "3.01.010" }, { "model": "adam opc server", "scope": "ne", "trust": 0.3, "vendor": "advantech", "version": "3.01.012" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2004" }, { "model": "simatic wincc flexible runtime", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "adam opc server", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "modbus rtu opc server", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "modbus tcp opc server", "version": "*" }, { "model": "protool sp3", "scope": "eq", "trust": 0.2, "vendor": "siemens", "version": "6.0*" }, { "model": "simatic wincc flexible sp2", "scope": "eq", "trust": 0.2, "vendor": "siemens", "version": "2008*" }, { "model": "simatic wincc flexible sp1", "scope": "eq", "trust": 0.2, "vendor": "siemens", "version": "2008*" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 0.2, "vendor": "siemens", "version": "2008*" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 0.2, "vendor": "siemens", "version": "2007*" }, { "model": "simatic wincc flexible sp1", "scope": "eq", "trust": 0.2, "vendor": "siemens", "version": "2005*" } ], "sources": [ { "db": "IVD", "id": "1a544d94-2354-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "5119408c-1f8a-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-3471" }, { "db": "CNVD", "id": "CNVD-2011-4690" }, { "db": "BID", "id": "50529" }, { "db": "BID", "id": "49405" }, { "db": "BID", "id": "49479" }, { "db": "JVNDB", "id": "JVNDB-2012-001544" }, { "db": "CNNVD", "id": "CNNVD-201111-163" }, { "db": "NVD", "id": "CVE-2011-1914" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:advantech:adam_opc_server", "vulnerable": true }, { "cpe22Uri": "cpe:/a:advantech:modbus_rtu_opc_server", "vulnerable": true }, { "cpe22Uri": "cpe:/a:advantech:modbus_tcp_opc_server", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2012-001544" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "CERT and ICST", "sources": [ { "db": "BID", "id": "50529" }, { "db": "CNNVD", "id": "CNNVD-201111-163" } ], "trust": 0.9 }, "cve": "CVE-2011-1914", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CVE-2011-1914", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.0, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 7.5, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2011-1914", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "1a544d94-2354-11e6-abef-000c29c66e3d", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": null, "accessVector": null, "authentication": null, "author": "IVD", "availabilityImpact": null, "baseScore": null, "confidentialityImpact": null, "exploitabilityScore": null, "id": "5119408c-1f8a-11e6-abef-000c29c66e3d", "impactScore": null, "integrityImpact": null, "severity": null, "trust": 0.2, "vectorString": null, "version": "unknown" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "VHN-49859", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2011-1914", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2011-1914", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-201111-163", "trust": 0.6, "value": "CRITICAL" }, { "author": "IVD", "id": "1a544d94-2354-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "CRITICAL" }, { "author": "IVD", "id": "5119408c-1f8a-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-49859", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "IVD", "id": "1a544d94-2354-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "5119408c-1f8a-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-49859" }, { "db": "JVNDB", "id": "JVNDB-2012-001544" }, { "db": "CNNVD", "id": "CNNVD-201111-163" }, { "db": "NVD", "id": "CVE-2011-1914" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Buffer overflow in the Advantech ADAM OLE for Process Control (OPC) Server ActiveX control in ADAM OPC Server before 3.01.012, Modbus RTU OPC Server before 3.01.010, and Modbus TCP OPC Server before 3.01.010 allows remote attackers to execute arbitrary code via unspecified vectors. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. A memory corruption vulnerability exists in Siemens SIMATIC WinCC Flexible. Due to an unspecified error in the tag emulator, an attacker can cause memory corruption by opening a specially crafted file, and the exploit can successfully execute arbitrary code. Advantech ADAM OPC Server is a Taiwanese industrial device server interface. Advantech ADAM OPC Server is prone to a remote buffer-overflow vulnerability because it fails to sufficiently validate user-supplied data. This issue affects an unspecified ActiveX control. Failed exploit attempts will likely result in denial-of-service conditions. \nThe following versions are affected:\nThe following products are affected:\nProTool 6.0 SP3\nWinCC flexible 2004\nWinCC flexible 2005\nWinCC flexible 2005 SP1\nWinCC flexible 2007\nWinCC flexible 2008\nWinCC flexible 2008 SP1\nWinCC flexible 2008 SP2. \nThe following products are affected:\nSiemens SIMATIC WinCC flexible Runtime\nSiemens SIMATIC WinCC (TIA Portal) Runtime Advanced. Successful exploitation of the vulnerability can execute arbitrary code. A failed attack may cause a denial of service. \n\nThe vulnerability are reported in versions 2005 SP1, 2007, 2008, 2008\nSP1, and 2008 SP2. Please see vendor\u0027s advisory for details. \n\nPROVIDED AND/OR DISCOVERED BY:\nBilly Rios and Terry McCorkle via ICS-CERT. ----------------------------------------------------------------------\n\nOvum says ad hoc tools are out-dated. The best practice approach?\nFast vulnerability intelligence, threat handling, and setup in one tool. \n\nRead the new report on the Secunia VIM:\nhttp://secunia.com/products/corporate/vim/ovum_2011_request/ \n\n----------------------------------------------------------------------\n\nTITLE:\nAdvantech OPC Server ADAM ActiveX Control Buffer Overflow\nVulnerability\n\nSECUNIA ADVISORY ID:\nSA46775\n\nVERIFY ADVISORY:\nSecunia.com\nhttp://secunia.com/advisories/46775/\nCustomer Area (Credentials Required)\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=46775\n\nRELEASE DATE:\n2011-11-07\n\nDISCUSS ADVISORY:\nhttp://secunia.com/advisories/46775/#comments\n\nAVAILABLE ON SITE AND IN CUSTOMER AREA:\n * Last Update\n * Popularity\n * Comments\n * Criticality Level\n * Impact\n * Where\n * Solution Status\n * Operating System / Software\n * CVE Reference(s)\n\nhttp://secunia.com/advisories/46775/\n\nONLY AVAILABLE IN CUSTOMER AREA:\n * Authentication Level\n * Report Reliability\n * Secunia PoC\n * Secunia Analysis\n * Systems Affected\n * Approve Distribution\n * Remediation Status\n * Secunia CVSS Score\n * CVSS\n\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=46775\n\nONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI:\n * AUTOMATED SCANNING\n\nhttp://secunia.com/vulnerability_scanning/personal/\nhttp://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/\n\nDESCRIPTION:\nA vulnerability has been reported in Advantech OPC Server, which can\nbe exploited by malicious people to compromise a user\u0027s system. \n\nThe vulnerability is reported in the following components:\n* Advantech ADAM OPC Server versions prior to V3.01.012. \n* Advantech Modbus RTU OPC Server versions prior to V3.01.010. \n* Advantech Modbus TCP OPC Server versions prior to V3.01.010. \n\nSOLUTION:\nReportedly a patch has been released. Contact the vendor for further\ninformation. \n\nPROVIDED AND/OR DISCOVERED BY:\nICS-CERT credits Security Research and Service Institute Information\nand Communication Security Technology Center (ICST). \n\nORIGINAL ADVISORY:\nICS-CERT:\nhttp://www.us-cert.gov/control_systems/pdf/ICSA-11-279-01.pdf\n\nOTHER REFERENCES:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nDEEP LINKS:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED DESCRIPTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED SOLUTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXPLOIT:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\n----------------------------------------------------------------------\n\nAbout:\nThis Advisory was delivered by Secunia as a free service to help\nprivate users keeping their systems up to date against the latest\nvulnerabilities. \n\nSubscribe:\nhttp://secunia.com/advisories/secunia_security_advisories/\n\nDefinitions: (Criticality, Where etc.)\nhttp://secunia.com/advisories/about_secunia_advisories/\n\n\nPlease Note:\nSecunia recommends that you verify all advisories you receive by\nclicking the link. \nSecunia NEVER sends attached files with advisories. \nSecunia does not advise people to install third party patches, only\nuse those supplied by the vendor. \n\n----------------------------------------------------------------------\n\nUnsubscribe: Secunia Security Advisories\nhttp://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org\n\n----------------------------------------------------------------------\n\n\n", "sources": [ { "db": "NVD", "id": "CVE-2011-1914" }, { "db": "JVNDB", "id": "JVNDB-2012-001544" }, { "db": "CNVD", "id": "CNVD-2011-3471" }, { "db": "CNVD", "id": "CNVD-2011-4690" }, { "db": "BID", "id": "50529" }, { "db": "BID", "id": "49405" }, { "db": "BID", "id": "49479" }, { "db": "IVD", "id": "1a544d94-2354-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "5119408c-1f8a-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-49859" }, { "db": "PACKETSTORM", "id": "104678" }, { "db": "PACKETSTORM", "id": "106765" } ], "trust": 4.14 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2011-1914", "trust": 3.9 }, { "db": "ICS CERT", "id": "ICSA-11-279-01", "trust": 3.5 }, { "db": "BID", "id": "49405", "trust": 1.5 }, { "db": "BID", "id": "50529", "trust": 1.0 }, { "db": "CNNVD", "id": "CNNVD-201111-163", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2011-4690", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2011-3471", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2012-001544", "trust": 0.8 }, { "db": "SECUNIA", "id": "46775", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-11-175-02", "trust": 0.7 }, { "db": "CNNVD", "id": "CNNVD-201108-546", "trust": 0.6 }, { "db": "NSFOCUS", "id": "17671", "trust": 0.6 }, { "db": "NSFOCUS", "id": "18130", "trust": 0.6 }, { "db": "BID", "id": "49479", "trust": 0.4 }, { "db": "IVD", "id": "1A544D94-2354-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "IVD", "id": "5119408C-1F8A-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "SECUNIA", "id": "45770", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-49859", "trust": 0.1 }, { "db": "PACKETSTORM", "id": "104678", "trust": 0.1 }, { "db": "PACKETSTORM", "id": "106765", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "1a544d94-2354-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "5119408c-1f8a-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-3471" }, { "db": "CNVD", "id": "CNVD-2011-4690" }, { "db": "VULHUB", "id": "VHN-49859" }, { "db": "BID", "id": "50529" }, { "db": "BID", "id": "49405" }, { "db": "BID", "id": "49479" }, { "db": "JVNDB", "id": "JVNDB-2012-001544" }, { "db": "PACKETSTORM", "id": "104678" }, { "db": "PACKETSTORM", "id": "106765" }, { "db": "CNNVD", "id": "CNNVD-201108-546" }, { "db": "CNNVD", "id": "CNNVD-201111-163" }, { "db": "NVD", "id": "CVE-2011-1914" } ] }, "id": "VAR-201202-0005", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "1a544d94-2354-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "5119408c-1f8a-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-3471" }, { "db": "CNVD", "id": "CNVD-2011-4690" }, { "db": "VULHUB", "id": "VHN-49859" } ], "trust": 2.386455681111111 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 1.6 } ], "sources": [ { "db": "IVD", "id": "1a544d94-2354-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "5119408c-1f8a-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-3471" }, { "db": "CNVD", "id": "CNVD-2011-4690" } ] }, "last_update_date": "2024-11-23T21:46:31.209000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "OPC Server", "trust": 0.8, "url": "http://www.advantech.co.jp/products/OPC-Server/mod_7396B07A-5CAE-463C-947B-2EED9E3A2B79.aspx" }, { "title": "\u30d1\u30fc\u30c8\u30ca\u30fc\u60c5\u5831", "trust": 0.8, "url": "http://www.advantech.co.jp/support-AJP/distributors.asp" }, { "title": "Top Page", "trust": 0.8, "url": "http://www.advantech.co.jp/" }, { "title": "Patch for Siemens SIMATIC WinCC Flexible Tag Simulator Memory Corruption Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/4976" }, { "title": "Advantech ADAM OPC Server ActiveX Control Buffer Overflow Vulnerability Patch", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/5790" }, { "title": "ModbusTCP OPC Server_3_01_013", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=42708" }, { "title": "ADAM OPC Server_3_01_012", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=42710" }, { "title": "ModbusRTU OPC Server_3_01_010", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=42709" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2011-3471" }, { "db": "CNVD", "id": "CNVD-2011-4690" }, { "db": "JVNDB", "id": "JVNDB-2012-001544" }, { "db": "CNNVD", "id": "CNNVD-201111-163" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-119", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-49859" }, { "db": "JVNDB", "id": "JVNDB-2012-001544" }, { "db": "NVD", "id": "CVE-2011-1914" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.5, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-11-279-01.pdf" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-1914" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-1914" }, { "trust": 0.7, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-11-175-02.pdf" }, { "trust": 0.7, "url": "http://support.automation.siemens.com/ww/llisapi.dll?func=cslib.csinfo\u0026lang=en\u0026objid=50182361" }, { "trust": 0.6, "url": "http://www.securityfocus.com/bid/49405http" }, { "trust": 0.6, "url": "http://www.securityfocus.com/bid/49405" }, { "trust": 0.6, "url": "http://secunia.com/advisories/46775" }, { "trust": 0.6, "url": "http://www.securityfocus.com/bid/50529" }, { "trust": 0.6, "url": "http://www.nsfocus.net/vulndb/18130" }, { "trust": 0.6, "url": "http://www.nsfocus.net/vulndb/17671" }, { "trust": 0.3, "url": "http://webaccess.advantech.com/product.php" }, { "trust": 0.2, "url": "http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/" }, { "trust": 0.2, "url": "http://secunia.com/vulnerability_intelligence/" }, { "trust": 0.2, "url": "http://secunia.com/advisories/secunia_security_advisories/" }, { "trust": 0.2, "url": "http://secunia.com/vulnerability_scanning/personal/" }, { "trust": 0.2, "url": "http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org" }, { "trust": 0.2, "url": "http://secunia.com/advisories/about_secunia_advisories/" }, { "trust": 0.1, "url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=45770" }, { "trust": 0.1, "url": "http://secunia.com/advisories/45770/#comments" }, { "trust": 0.1, "url": "http://secunia.com/blog/242" }, { "trust": 0.1, "url": "http://secunia.com/advisories/45770/" }, { "trust": 0.1, "url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=46775" }, { "trust": 0.1, "url": "http://secunia.com/products/corporate/vim/ovum_2011_request/" }, { "trust": 0.1, "url": "http://secunia.com/advisories/46775/" }, { "trust": 0.1, "url": "http://secunia.com/advisories/46775/#comments" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2011-3471" }, { "db": "CNVD", "id": "CNVD-2011-4690" }, { "db": "VULHUB", "id": "VHN-49859" }, { "db": "BID", "id": "50529" }, { "db": "BID", "id": "49405" }, { "db": "BID", "id": "49479" }, { "db": "JVNDB", "id": "JVNDB-2012-001544" }, { "db": "PACKETSTORM", "id": "104678" }, { "db": "PACKETSTORM", "id": "106765" }, { "db": "CNNVD", "id": "CNNVD-201108-546" }, { "db": "CNNVD", "id": "CNNVD-201111-163" }, { "db": "NVD", "id": "CVE-2011-1914" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "1a544d94-2354-11e6-abef-000c29c66e3d" }, { "db": "IVD", "id": "5119408c-1f8a-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-3471" }, { "db": "CNVD", "id": "CNVD-2011-4690" }, { "db": "VULHUB", "id": "VHN-49859" }, { "db": "BID", "id": "50529" }, { "db": "BID", "id": "49405" }, { "db": "BID", "id": "49479" }, { "db": "JVNDB", "id": "JVNDB-2012-001544" }, { "db": "PACKETSTORM", "id": "104678" }, { "db": "PACKETSTORM", "id": "106765" }, { "db": "CNNVD", "id": "CNNVD-201108-546" }, { "db": "CNNVD", "id": "CNNVD-201111-163" }, { "db": "NVD", "id": "CVE-2011-1914" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2011-11-07T00:00:00", "db": "IVD", "id": "1a544d94-2354-11e6-abef-000c29c66e3d" }, { "date": "2011-09-02T00:00:00", "db": "IVD", "id": "5119408c-1f8a-11e6-abef-000c29c66e3d" }, { "date": "2011-09-02T00:00:00", "db": "CNVD", "id": "CNVD-2011-3471" }, { "date": "2011-11-07T00:00:00", "db": "CNVD", "id": "CNVD-2011-4690" }, { "date": "2012-02-21T00:00:00", "db": "VULHUB", "id": "VHN-49859" }, { "date": "2011-11-04T00:00:00", "db": "BID", "id": "50529" }, { "date": "2011-09-01T00:00:00", "db": "BID", "id": "49405" }, { "date": "2011-09-06T00:00:00", "db": "BID", "id": "49479" }, { "date": "2012-02-23T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001544" }, { "date": "2011-09-01T12:46:24", "db": "PACKETSTORM", "id": "104678" }, { "date": "2011-11-09T12:04:37", "db": "PACKETSTORM", "id": "106765" }, { "date": "1900-01-01T00:00:00", "db": "CNNVD", "id": "CNNVD-201108-546" }, { "date": "1900-01-01T00:00:00", "db": "CNNVD", "id": "CNNVD-201111-163" }, { "date": "2012-02-21T13:31:55.877000", "db": "NVD", "id": "CVE-2011-1914" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2011-09-02T00:00:00", "db": "CNVD", "id": "CNVD-2011-3471" }, { "date": "2011-11-07T00:00:00", "db": "CNVD", "id": "CNVD-2011-4690" }, { "date": "2012-02-23T00:00:00", "db": "VULHUB", "id": "VHN-49859" }, { "date": "2011-11-04T00:00:00", "db": "BID", "id": "50529" }, { "date": "2011-09-01T00:00:00", "db": "BID", "id": "49405" }, { "date": "2011-09-06T00:00:00", "db": "BID", "id": "49479" }, { "date": "2012-02-23T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001544" }, { "date": "2011-09-05T00:00:00", "db": "CNNVD", "id": "CNNVD-201108-546" }, { "date": "2011-11-08T00:00:00", "db": "CNNVD", "id": "CNNVD-201111-163" }, { "date": "2024-11-21T01:27:18.263000", "db": "NVD", "id": "CVE-2011-1914" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201108-546" }, { "db": "CNNVD", "id": "CNNVD-201111-163" } ], "trust": 1.2 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Advantech ADAM OPC Server ActiveX Control Buffer Overflow Vulnerability", "sources": [ { "db": "IVD", "id": "1a544d94-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-4690" }, { "db": "BID", "id": "50529" } ], "trust": 1.1 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Buffer overflow", "sources": [ { "db": "IVD", "id": "1a544d94-2354-11e6-abef-000c29c66e3d" }, { "db": "CNNVD", "id": "CNNVD-201111-163" } ], "trust": 0.8 } }
var-202006-1828
Vulnerability from variot
A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges. plural SIMATIC The product contains vulnerabilities in unquoted search paths or elements.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Opera Software, Opera, etc. are all products of Opera Software in Norway. Opera is a web browser, Siemens SIMATIC S7-1500, etc. are all products of German Siemens (Siemens). SIMATIC S7-1500 is a programmable logic controller. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. Code issue vulnerabilities exist in several products. This vulnerability stems from improper design or implementation problems in the code development process of network systems or products
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-1828", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic pcs neo", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic prosave", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic wincc", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "7.5" }, { "model": "simatic automatic tool", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic wincc runtime professional", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "13" }, { "model": "simatic pcs 7", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics starter commissioning tool", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic wincc open architecture", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "3.17" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic net pc", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic net pc", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic step 7", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "13" }, { "model": "simatic wincc runtime professional", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinec network management system", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic step 7", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinema server", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic step 7", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "5.6" }, { "model": "simatic wincc", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "7.4" }, { "model": "sinamics startdrive", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinumerik one virtual", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinumerik operate", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic wincc open architecture", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "3.16" }, { "model": "simatic wincc", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "7.4" }, { "model": "simatic s7-1500 software controller", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "21.8" }, { "model": "simatic step 7", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.6" }, { "model": "simatic automation tool", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic net pc software", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic pcs 7", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic pcs neo", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic prosave", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic step 7", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc oa", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime professional", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006496" }, { "db": "NVD", "id": "CVE-2020-7580" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:siemens:simatic_automation_tool", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_net_pc-software", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_pcs_7", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_pcs_neo", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_prosave", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_step_7", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_open_architecture", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_runtime_professional", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006496" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Ander Martinez of Titanium Industrial Security and INCIBE reported this vulnerability to Siemens.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-636" } ], "trust": 0.6 }, "cve": "CVE-2020-7580", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 3.9, "id": "CVE-2020-7580", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.1, "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Local", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 7.2, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "JVNDB-2020-006496", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 3.9, "id": "VHN-185705", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:L/AC:L/AU:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.8, "id": "CVE-2020-7580", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.7, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006496", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-7580", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "JVNDB-2020-006496", "trust": 0.8, "value": "Medium" }, { "author": "CNNVD", "id": "CNNVD-202006-636", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULHUB", "id": "VHN-185705", "trust": 0.1, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2020-7580", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-185705" }, { "db": "VULMON", "id": "CVE-2020-7580" }, { "db": "JVNDB", "id": "JVNDB-2020-006496" }, { "db": "CNNVD", "id": "CNNVD-202006-636" }, { "db": "NVD", "id": "CVE-2020-7580" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC Automation Tool (All versions \u003c V4 SP2), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Upd3), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC ProSave (All versions \u003c V17), SIMATIC S7-1500 Software Controller (All versions \u003c V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMATIC STEP 7 V5 (All versions \u003c V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions \u003c V3.16 P018), SIMATIC WinCC OA V3.17 (All versions \u003c V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions \u003c V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 3), SINAMICS STARTER (All Versions \u003c V5.4 HF2), SINAMICS Startdrive (All Versions \u003c V16 Update 3), SINEC NMS (All versions \u003c V1.0 SP2), SINEMA Server (All versions \u003c V14 SP3), SINUMERIK ONE virtual (All Versions \u003c V6.14), SINUMERIK Operate (All Versions \u003c V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges. plural SIMATIC The product contains vulnerabilities in unquoted search paths or elements.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Opera Software, Opera, etc. are all products of Opera Software in Norway. Opera is a web browser, Siemens SIMATIC S7-1500, etc. are all products of German Siemens (Siemens). SIMATIC S7-1500 is a programmable logic controller. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. Code issue vulnerabilities exist in several products. This vulnerability stems from improper design or implementation problems in the code development process of network systems or products", "sources": [ { "db": "NVD", "id": "CVE-2020-7580" }, { "db": "JVNDB", "id": "JVNDB-2020-006496" }, { "db": "VULHUB", "id": "VHN-185705" }, { "db": "VULMON", "id": "CVE-2020-7580" } ], "trust": 1.8 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-7580", "trust": 2.6 }, { "db": "ICS CERT", "id": "ICSA-20-161-04", "trust": 2.6 }, { "db": "SIEMENS", "id": "SSA-312271", "trust": 1.8 }, { "db": "JVN", "id": "JVNVU97501786", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2020-006496", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202006-636", "trust": 0.7 }, { "db": "AUSCERT", "id": "ESB-2020.2015", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-185705", "trust": 0.1 }, { "db": "VULMON", "id": "CVE-2020-7580", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-185705" }, { "db": "VULMON", "id": "CVE-2020-7580" }, { "db": "JVNDB", "id": "JVNDB-2020-006496" }, { "db": "CNNVD", "id": "CNNVD-202006-636" }, { "db": "NVD", "id": "CVE-2020-7580" } ] }, "id": "VAR-202006-1828", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-185705" } ], "trust": 0.6991104690909089 }, "last_update_date": "2024-11-23T20:22:32.187000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-312271:Unquoted Search Path Vulnerabilities in Windows-based Industrial Software Applications", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf" }, { "title": "Multiple Siemens Product code issue vulnerability fixes", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=121186" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=9c51f352314e5a42566d9203d2f1e0a2" } ], "sources": [ { "db": "VULMON", "id": "CVE-2020-7580" }, { "db": "JVNDB", "id": "JVNDB-2020-006496" }, { "db": "CNNVD", "id": "CNNVD-202006-636" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-428", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-185705" }, { "db": "JVNDB", "id": "JVNDB-2020-006496" }, { "db": "NVD", "id": "CVE-2020-7580" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.2, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04" }, { "trust": 1.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-7580" }, { "trust": 1.2, "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-04" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7580" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu97501786/" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/simatic-code-execution-via-windows-exe-extension-32489" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2020.2015/" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/428.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-161-04" } ], "sources": [ { "db": "VULHUB", "id": "VHN-185705" }, { "db": "VULMON", "id": "CVE-2020-7580" }, { "db": "JVNDB", "id": "JVNDB-2020-006496" }, { "db": "CNNVD", "id": "CNNVD-202006-636" }, { "db": "NVD", "id": "CVE-2020-7580" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-185705" }, { "db": "VULMON", "id": "CVE-2020-7580" }, { "db": "JVNDB", "id": "JVNDB-2020-006496" }, { "db": "CNNVD", "id": "CNNVD-202006-636" }, { "db": "NVD", "id": "CVE-2020-7580" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-10T00:00:00", "db": "VULHUB", "id": "VHN-185705" }, { "date": "2020-06-10T00:00:00", "db": "VULMON", "id": "CVE-2020-7580" }, { "date": "2020-07-09T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006496" }, { "date": "2020-06-09T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-636" }, { "date": "2020-06-10T17:15:12.347000", "db": "NVD", "id": "CVE-2020-7580" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-12-13T00:00:00", "db": "VULHUB", "id": "VHN-185705" }, { "date": "2022-04-12T00:00:00", "db": "VULMON", "id": "CVE-2020-7580" }, { "date": "2020-07-09T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006496" }, { "date": "2022-12-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-636" }, { "date": "2024-11-21T05:37:24.840000", "db": "NVD", "id": "CVE-2020-7580" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-636" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural SIMATIC Vulnerabilities in unquoted search paths or elements in products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006496" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "code problem", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-636" } ], "trust": 0.6 } }
var-201905-0114
Vulnerability from variot
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known. plural SIMATIC The product contains cryptographic vulnerabilities.Information may be obtained. Multiple Siemens Products are prone to following security vulnerabilities: 1. An information-disclosure vulnerability 2. A cross-site-scripting vulnerability 3. A security vulnerability An attacker may leverage these issues to obtain potentially sensitive information and to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and to launch other attacks. Siemens SIMATIC WinCC, etc. are all products of Siemens (Siemens) in Germany. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. Siemens SIMATIC HMI Comfort Panels is a touch panel device. Siemens SIMATIC HMI Comfort Outdoor Panels is a touch panel device specially designed for outdoor use
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201905-0114", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic hmi comfort outdoor panels", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic wincc runtime", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic wincc \\", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi mp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort panels", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi op", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi tp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort outdoor panels", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi comfort panels", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime professional", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15.1" }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15.1" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v15.1" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v15" }, { "model": "simatic hmi ktp mobile panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15" }, { "model": "simatic hmi comfort outdoor panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15" }, { "model": "simatic hmi classic devices", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc runtime professional update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "v15.11" }, { "model": "simatic wincc runtime advanced update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "15.11" }, { "model": "simatic wincc update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "v15.11" }, { "model": "simatic hmi ktp mobile update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "15.11" }, { "model": "simatic hmi comfort panels update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "15.11" }, { "model": "simatic hmi comfort outdoor panels update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "15.11" } ], "sources": [ { "db": "BID", "id": "108412" }, { "db": "JVNDB", "id": "JVNDB-2019-004633" }, { "db": "NVD", "id": "CVE-2019-6576" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_outdoor_panels_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_runtime_professional", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-004633" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens ProductCERT reported these vulnerabilities to NCCIC.,Siemens ProductCERT", "sources": [ { "db": "CNNVD", "id": "CNNVD-201905-589" } ], "trust": 0.6 }, "cve": "CVE-2019-6576", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2019-6576", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "VHN-158011", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2019-6576", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2019-6576", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2019-6576", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-201905-589", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-158011", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-158011" }, { "db": "JVNDB", "id": "JVNDB-2019-004633" }, { "db": "CNNVD", "id": "CNNVD-201905-589" }, { "db": "NVD", "id": "CVE-2019-6576" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003c V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003c V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known. plural SIMATIC The product contains cryptographic vulnerabilities.Information may be obtained. Multiple Siemens Products are prone to following security vulnerabilities:\n1. An information-disclosure vulnerability\n2. A cross-site-scripting vulnerability\n3. A security vulnerability\nAn attacker may leverage these issues to obtain potentially sensitive information and to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and to launch other attacks. Siemens SIMATIC WinCC, etc. are all products of Siemens (Siemens) in Germany. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. Siemens SIMATIC HMI Comfort Panels is a touch panel device. Siemens SIMATIC HMI Comfort Outdoor Panels is a touch panel device specially designed for outdoor use", "sources": [ { "db": "NVD", "id": "CVE-2019-6576" }, { "db": "JVNDB", "id": "JVNDB-2019-004633" }, { "db": "BID", "id": "108412" }, { "db": "VULHUB", "id": "VHN-158011" } ], "trust": 1.98 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "ICS CERT", "id": "ICSA-19-134-09", "trust": 2.8 }, { "db": "NVD", "id": "CVE-2019-6576", "trust": 2.8 }, { "db": "BID", "id": "108412", "trust": 2.0 }, { "db": "SIEMENS", "id": "SSA-804486", "trust": 1.7 }, { "db": "JVNDB", "id": "JVNDB-2019-004633", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201905-589", "trust": 0.7 }, { "db": "ICS CERT", "id": "ICSA-19-134-02", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2019.1716.2", "trust": 0.6 }, { "db": "CNVD", "id": "CNVD-2021-54366", "trust": 0.1 }, { "db": "VULHUB", "id": "VHN-158011", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-158011" }, { "db": "BID", "id": "108412" }, { "db": "JVNDB", "id": "JVNDB-2019-004633" }, { "db": "CNNVD", "id": "CNNVD-201905-589" }, { "db": "NVD", "id": "CVE-2019-6576" } ] }, "id": "VAR-201905-0114", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-158011" } ], "trust": 0.7545892989999999 }, "last_update_date": "2024-11-23T21:37:16.690000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-804486", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf" }, { "title": "Siemens SIMATIC Panels and WinCC Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=92739" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-004633" }, { "db": "CNNVD", "id": "CNNVD-201905-589" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-310", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-158011" }, { "db": "JVNDB", "id": "JVNDB-2019-004633" }, { "db": "NVD", "id": "CVE-2019-6576" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "http://www.securityfocus.com/bid/108412" }, { "trust": 1.9, "url": "https://www.us-cert.gov/ics/advisories/icsa-19-134-09" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-6576" }, { "trust": 0.9, "url": "http://subscriber.communications.siemens.com/" }, { "trust": 0.9, "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-134-09" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-6576" }, { "trust": 0.6, "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-134-02-0" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/simatic-wincc-multiple-vulnerabilities-29288" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/80946" } ], "sources": [ { "db": "VULHUB", "id": "VHN-158011" }, { "db": "BID", "id": "108412" }, { "db": "JVNDB", "id": "JVNDB-2019-004633" }, { "db": "CNNVD", "id": "CNNVD-201905-589" }, { "db": "NVD", "id": "CVE-2019-6576" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-158011" }, { "db": "BID", "id": "108412" }, { "db": "JVNDB", "id": "JVNDB-2019-004633" }, { "db": "CNNVD", "id": "CNNVD-201905-589" }, { "db": "NVD", "id": "CVE-2019-6576" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-05-14T00:00:00", "db": "VULHUB", "id": "VHN-158011" }, { "date": "2019-05-14T00:00:00", "db": "BID", "id": "108412" }, { "date": "2019-06-05T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-004633" }, { "date": "2019-05-14T00:00:00", "db": "CNNVD", "id": "CNNVD-201905-589" }, { "date": "2019-05-14T20:29:04.560000", "db": "NVD", "id": "CVE-2019-6576" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-05-22T00:00:00", "db": "VULHUB", "id": "VHN-158011" }, { "date": "2019-05-14T00:00:00", "db": "BID", "id": "108412" }, { "date": "2019-07-09T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-004633" }, { "date": "2019-06-20T00:00:00", "db": "CNNVD", "id": "CNNVD-201905-589" }, { "date": "2024-11-21T04:46:44.130000", "db": "NVD", "id": "CVE-2019-6576" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201905-589" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural SIMATIC Cryptographic vulnerabilities in products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-004633" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "encryption problem", "sources": [ { "db": "CNNVD", "id": "CNNVD-201905-589" } ], "trust": 0.6 } }
var-201812-0345
Vulnerability from variot
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. plural SIMATIC The product contains an input validation vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Siemens SIMATIC Panels and SIMATIC WinCC (TIA Portal) are products of Siemens AG, Germany. Siemens SIMATIC Panels is a human interface panel. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. A code injection vulnerability exists in Siemens SIMATIC Panels and SIMATIC WinCC (TIA Portal), which can be exploited by an attacker to inject HTTP headers with malicious links. Multiple Siemens Products are prone to an HTTP header-injection vulnerability because it fails to sufficiently sanitize user input. This may aid in further attacks
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201812-0345", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "14.0" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "14.0" }, { "model": "simatic hmi mp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi op", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "14.0" }, { "model": "simatic wincc \\", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "14.0" }, { "model": "simatic hmi comfort outdoor panels", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "14.0" }, { "model": "simatic wincc runtime", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "14.0" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "14.0" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "14.0" }, { "model": "simatic hmi tp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort panels", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "14.0" }, { "model": "simatic hmi comfort outdoor panels", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi comfort panels", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime professional", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi comfort panels 4\" 22\"", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "-\u003c14" }, { "model": "simatic hmi comfort outdoor panels 7\\\" and 15\\\"", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "14" }, { "model": "simatic hmi ktp mobile panels", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "14" }, { "model": "simatic wincc runtime advanced", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "14" }, { "model": "simatic wincc runtime professional", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "14" }, { "model": "simatic wincc", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "14" }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "simatic wincc runtime", "version": "*" }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "13" }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "13" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "12" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v120" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v110" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v13" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v10" }, { "model": "simatic hmi ktp mobile panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "22" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "13" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "12" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi comfort outdoor panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi classic devices", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc runtime professional", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "14" }, { "model": "simatic wincc runtime advanced", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "v14" }, { "model": "simatic wincc", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "v14" }, { "model": "simatic hmi ktp mobile panels update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "154" }, { "model": "simatic hmi comfort panels", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "14" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi comfort panels", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi mp", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi op", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi comfort outdoor panels", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi ktp mobile panels ktp400f", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi ktp mobile panels ktp700", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi ktp mobile panels ktp700f", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi ktp mobile panels ktp900", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi ktp mobile panels ktp900f", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic wincc tia portal", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi tp", "version": "*" } ], "sources": [ { "db": "IVD", "id": "7d80ae62-463f-11e9-b905-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-25432" }, { "db": "BID", "id": "105931" }, { "db": "JVNDB", "id": "JVNDB-2018-014527" }, { "db": "NVD", "id": "CVE-2018-13814" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_outdoor_panels_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_runtime_professional", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-014527" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "The vendor reported this issue.", "sources": [ { "db": "BID", "id": "105931" } ], "trust": 0.3 }, "cve": "CVE-2018-13814", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "CVE-2018-13814", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2018-25432", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "7d80ae62-463f-11e9-b905-000c29342cb1", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "version": "2.9 [IVD]" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "VHN-123911", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2018-13814", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-13814", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2018-13814", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2018-25432", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201811-488", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "7d80ae62-463f-11e9-b905-000c29342cb1", "trust": 0.2, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-123911", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "IVD", "id": "7d80ae62-463f-11e9-b905-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-25432" }, { "db": "VULHUB", "id": "VHN-123911" }, { "db": "JVNDB", "id": "JVNDB-2018-014527" }, { "db": "CNNVD", "id": "CNNVD-201811-488" }, { "db": "NVD", "id": "CVE-2018-13814" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V14), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V14), SIMATIC WinCC Runtime Advanced (All versions \u003c V14), SIMATIC WinCC Runtime Professional (All versions \u003c V14), SIMATIC WinCC (TIA Portal) (All versions \u003c V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. plural SIMATIC The product contains an input validation vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Siemens SIMATIC Panels and SIMATIC WinCC (TIA Portal) are products of Siemens AG, Germany. Siemens SIMATIC Panels is a human interface panel. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. A code injection vulnerability exists in Siemens SIMATIC Panels and SIMATIC WinCC (TIA Portal), which can be exploited by an attacker to inject HTTP headers with malicious links. Multiple Siemens Products are prone to an HTTP header-injection vulnerability because it fails to sufficiently sanitize user input. This may aid in further attacks", "sources": [ { "db": "NVD", "id": "CVE-2018-13814" }, { "db": "JVNDB", "id": "JVNDB-2018-014527" }, { "db": "CNVD", "id": "CNVD-2018-25432" }, { "db": "BID", "id": "105931" }, { "db": "IVD", "id": "7d80ae62-463f-11e9-b905-000c29342cb1" }, { "db": "VULHUB", "id": "VHN-123911" } ], "trust": 2.7 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-13814", "trust": 3.6 }, { "db": "ICS CERT", "id": "ICSA-18-317-03", "trust": 2.3 }, { "db": "BID", "id": "105931", "trust": 2.0 }, { "db": "SIEMENS", "id": "SSA-944083", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-201811-488", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2018-25432", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2018-014527", "trust": 0.8 }, { "db": "IVD", "id": "7D80AE62-463F-11E9-B905-000C29342CB1", "trust": 0.2 }, { "db": "SEEBUG", "id": "SSVID-98853", "trust": 0.1 }, { "db": "VULHUB", "id": "VHN-123911", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "7d80ae62-463f-11e9-b905-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-25432" }, { "db": "VULHUB", "id": "VHN-123911" }, { "db": "BID", "id": "105931" }, { "db": "JVNDB", "id": "JVNDB-2018-014527" }, { "db": "CNNVD", "id": "CNNVD-201811-488" }, { "db": "NVD", "id": "CVE-2018-13814" } ] }, "id": "VAR-201812-0345", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "7d80ae62-463f-11e9-b905-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-25432" }, { "db": "VULHUB", "id": "VHN-123911" } ], "trust": 1.53959078625 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "7d80ae62-463f-11e9-b905-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-25432" } ] }, "last_update_date": "2024-11-23T22:34:04.145000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-944083", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf" }, { "title": "Patch for Siemens SIMATIC Panels and SIMATIC WinCC code injection vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/147353" }, { "title": "Siemens SIMATIC Panels and SIMATIC WinCC Fixes for code injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=86889" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-25432" }, { "db": "JVNDB", "id": "JVNDB-2018-014527" }, { "db": "CNNVD", "id": "CNNVD-201811-488" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-20", "trust": 1.9 }, { "problemtype": "CWE-113", "trust": 1.0 } ], "sources": [ { "db": "VULHUB", "id": "VHN-123911" }, { "db": "JVNDB", "id": "JVNDB-2018-014527" }, { "db": "NVD", "id": "CVE-2018-13814" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-317-03" }, { "trust": 1.7, "url": "http://www.securityfocus.com/bid/105931" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-13814" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-13814" }, { "trust": 0.3, "url": "http://subscriber.communications.siemens.com/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-25432" }, { "db": "VULHUB", "id": "VHN-123911" }, { "db": "BID", "id": "105931" }, { "db": "JVNDB", "id": "JVNDB-2018-014527" }, { "db": "CNNVD", "id": "CNNVD-201811-488" }, { "db": "NVD", "id": "CVE-2018-13814" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "7d80ae62-463f-11e9-b905-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-25432" }, { "db": "VULHUB", "id": "VHN-123911" }, { "db": "BID", "id": "105931" }, { "db": "JVNDB", "id": "JVNDB-2018-014527" }, { "db": "CNNVD", "id": "CNNVD-201811-488" }, { "db": "NVD", "id": "CVE-2018-13814" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-12-14T00:00:00", "db": "IVD", "id": "7d80ae62-463f-11e9-b905-000c29342cb1" }, { "date": "2018-12-14T00:00:00", "db": "CNVD", "id": "CNVD-2018-25432" }, { "date": "2018-12-13T00:00:00", "db": "VULHUB", "id": "VHN-123911" }, { "date": "2018-11-13T00:00:00", "db": "BID", "id": "105931" }, { "date": "2019-03-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-014527" }, { "date": "2018-11-15T00:00:00", "db": "CNNVD", "id": "CNNVD-201811-488" }, { "date": "2018-12-13T16:29:00.350000", "db": "NVD", "id": "CVE-2018-13814" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-12-14T00:00:00", "db": "CNVD", "id": "CNVD-2018-25432" }, { "date": "2019-10-09T00:00:00", "db": "VULHUB", "id": "VHN-123911" }, { "date": "2018-11-13T00:00:00", "db": "BID", "id": "105931" }, { "date": "2019-03-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-014527" }, { "date": "2019-10-17T00:00:00", "db": "CNNVD", "id": "CNNVD-201811-488" }, { "date": "2024-11-21T03:48:07.560000", "db": "NVD", "id": "CVE-2018-13814" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201811-488" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens SIMATIC Panels and SIMATIC WinCC code injection vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2018-25432" }, { "db": "CNNVD", "id": "CNNVD-201811-488" } ], "trust": 1.2 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Input validation error", "sources": [ { "db": "IVD", "id": "7d80ae62-463f-11e9-b905-000c29342cb1" }, { "db": "BID", "id": "105931" }, { "db": "CNNVD", "id": "CNNVD-201811-488" } ], "trust": 1.1 } }
var-202105-0692
Vulnerability from variot
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition. Several Siemens products are vulnerable to a lack of memory release after expiration.Denial of service (DoS) It may be put into a state. Siemens SmartVNC is an industrial control equipment of Germany's Siemens (Siemens) company. Provides an access to the smartserver function in the HMI. Attackers can use the vulnerability to cause a denial of service. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202105-0692", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics sl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinamics gm150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic wincc runtime advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinamics sm150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinamics sm150i", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic wincc runtime advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gh150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics sm120", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics sh150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics sh150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sl150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sm120", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sm150i", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi comfort outdoor panels 7\"", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics gh150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sm150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics gl150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics gm150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sl150", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics sm150", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics sm150i", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics gh150", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics gl150 (with option", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x30)" }, { "model": "sinamics gm150 (with option", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x30)" }, { "model": "sinamics sh150", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics sm120", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-67537" }, { "db": "JVNDB", "id": "JVNDB-2021-006951" }, { "db": "NVD", "id": "CVE-2021-27386" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-477" } ], "trust": 0.6 }, "cve": "CVE-2021-27386", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2021-27386", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2021-67537", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2021-27386", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-27386", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-27386", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2021-27386", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-67537", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202105-477", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-27386", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-67537" }, { "db": "VULMON", "id": "CVE-2021-27386" }, { "db": "JVNDB", "id": "JVNDB-2021-006951" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-477" }, { "db": "NVD", "id": "CVE-2021-27386" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition. Several Siemens products are vulnerable to a lack of memory release after expiration.Denial of service (DoS) It may be put into a state. Siemens SmartVNC is an industrial control equipment of Germany\u0027s Siemens (Siemens) company. Provides an access to the smartserver function in the HMI. Attackers can use the vulnerability to cause a denial of service. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements", "sources": [ { "db": "NVD", "id": "CVE-2021-27386" }, { "db": "JVNDB", "id": "JVNDB-2021-006951" }, { "db": "CNVD", "id": "CNVD-2021-67537" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULMON", "id": "CVE-2021-27386" } ], "trust": 2.79 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-27386", "trust": 3.9 }, { "db": "ICS CERT", "id": "ICSA-21-131-12", "trust": 2.4 }, { "db": "SIEMENS", "id": "SSA-286838", "trust": 2.3 }, { "db": "SIEMENS", "id": "SSA-538778", "trust": 1.7 }, { "db": "JVN", "id": "JVNVU91051134", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-006951", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-67537", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021051206", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-21-131-04", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202105-477", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-27386", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-67537" }, { "db": "VULMON", "id": "CVE-2021-27386" }, { "db": "JVNDB", "id": "JVNDB-2021-006951" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-477" }, { "db": "NVD", "id": "CVE-2021-27386" } ] }, "id": "VAR-202105-0692", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-67537" } ], "trust": 1.24530875 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-67537" } ] }, "last_update_date": "2024-08-14T12:18:07.716000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-286838 Siemens\u00a0Security\u00a0Advisory", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "title": "Patch for Siemens SmartVNC heap allocation leak vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/285861" }, { "title": "Siemens SmartVNC Buffer error vulnerability fix", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=151556" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=43c9c77785b8d29daef02185f41ca476" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=9465a8ef1f8c1b0042244cb02cfe271e" }, { "title": "CVE-2021-27386", "trust": 0.1, "url": "https://github.com/JamesGeee/CVE-2021-27386 " } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-67537" }, { "db": "VULMON", "id": "CVE-2021-27386" }, { "db": "JVNDB", "id": "JVNDB-2021-006951" }, { "db": "CNNVD", "id": "CNNVD-202105-477" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-401", "trust": 1.0 }, { "problemtype": "Lack of free memory after expiration (CWE-401) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006951" }, { "db": "NVD", "id": "CVE-2021-27386" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "trust": 2.2, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu91051134/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-27386" }, { "trust": 0.8, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-131-12" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021051206" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/smartvnc-multiple-vulnerabilities-35360" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/401.html" }, { "trust": 0.1, "url": "https://github.com/jamesgeee/cve-2021-27386" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://cert-portal.siemens.com/productcert/txt/ssa-286838.txt" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-67537" }, { "db": "VULMON", "id": "CVE-2021-27386" }, { "db": "JVNDB", "id": "JVNDB-2021-006951" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-477" }, { "db": "NVD", "id": "CVE-2021-27386" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-67537" }, { "db": "VULMON", "id": "CVE-2021-27386" }, { "db": "JVNDB", "id": "JVNDB-2021-006951" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-477" }, { "db": "NVD", "id": "CVE-2021-27386" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-09-02T00:00:00", "db": "CNVD", "id": "CNVD-2021-67537" }, { "date": "2021-05-12T00:00:00", "db": "VULMON", "id": "CVE-2021-27386" }, { "date": "2022-01-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-006951" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-05-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-477" }, { "date": "2021-05-12T14:15:11.767000", "db": "NVD", "id": "CVE-2021-27386" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "CNVD", "id": "CNVD-2021-67537" }, { "date": "2021-05-21T00:00:00", "db": "VULMON", "id": "CVE-2021-27386" }, { "date": "2022-01-26T07:30:00", "db": "JVNDB", "id": "JVNDB-2021-006951" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-10-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-477" }, { "date": "2022-01-04T17:22:06.867000", "db": "NVD", "id": "CVE-2021-27386" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-477" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Vulnerability regarding lack of memory release after expiration in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006951" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-975" } ], "trust": 0.6 } }
var-201202-0049
Vulnerability from variot
The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attackers to obtain access via a TCP session. plural Siemens Product TELNET Since the daemon does not authenticate, there is a vulnerability that allows easy access.By a third party TCP Access can easily be gained through a session. Siemens SIMATIC is an automation software in a single engineering environment. SIMATIC panels include the Telnet daemon by default, but the daemon does not implement any validation features. A vulnerability exists in several versions of Siemens SIMATIC WinCC due to the failure of the TELNET daemon to perform authentication. A remote attacker could use this vulnerability to gain access through a TCP session
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0049", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "mp" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "op" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "tp" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "2008" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "comfort_panels" }, { "model": "wincc runtime advanced", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "v11" }, { "model": "wincc", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "v11" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "mobile_panels" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "2007" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.4, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.4, "vendor": "siemens", "version": "2007" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.4, "vendor": "siemens", "version": "2005" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.4, "vendor": "siemens", "version": "2004" }, { "model": "simatic wincc", "scope": "eq", "trust": 1.4, "vendor": "siemens", "version": "v11" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2004" }, { "model": "wincc flexible runtime", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2005" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "comfort panels" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "mobile panels" }, { "model": "simatic wincc flexible rumtime", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "v11" }, { "model": "simatic wincc flexible runtime", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic hmi panels", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "wincc flexible runtime", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2004" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2005" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2007" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2008" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc", "version": "v11" }, { "model": "comfort panels", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "mobile panels", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "mp", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "op", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "tp", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc runtime advanced", "version": "v11" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible runtime", "version": "*" } ], "sources": [ { "db": "IVD", "id": "28d0ca64-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0464" }, { "db": "JVNDB", "id": "JVNDB-2012-001316" }, { "db": "CNNVD", "id": "CNNVD-201202-089" }, { "db": "NVD", "id": "CVE-2011-4514" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:siemens:simatic_hmi_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_flexible", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_flexible_runtime", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2012-001316" } ] }, "cve": "CVE-2011-4514", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CVE-2011-4514", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "28d0ca64-2354-11e6-abef-000c29c66e3d", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "VHN-52459", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2011-4514", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2011-4514", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-201202-089", "trust": 0.6, "value": "CRITICAL" }, { "author": "IVD", "id": "28d0ca64-2354-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "CRITICAL" }, { "author": "VULHUB", "id": "VHN-52459", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "IVD", "id": "28d0ca64-2354-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-52459" }, { "db": "JVNDB", "id": "JVNDB-2012-001316" }, { "db": "CNNVD", "id": "CNNVD-201202-089" }, { "db": "NVD", "id": "CVE-2011-4514" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attackers to obtain access via a TCP session. plural Siemens Product TELNET Since the daemon does not authenticate, there is a vulnerability that allows easy access.By a third party TCP Access can easily be gained through a session. Siemens SIMATIC is an automation software in a single engineering environment. SIMATIC panels include the Telnet daemon by default, but the daemon does not implement any validation features. A vulnerability exists in several versions of Siemens SIMATIC WinCC due to the failure of the TELNET daemon to perform authentication. A remote attacker could use this vulnerability to gain access through a TCP session", "sources": [ { "db": "NVD", "id": "CVE-2011-4514" }, { "db": "JVNDB", "id": "JVNDB-2012-001316" }, { "db": "CNVD", "id": "CNVD-2012-0464" }, { "db": "IVD", "id": "28d0ca64-2354-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-52459" } ], "trust": 2.43 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2011-4514", "trust": 3.3 }, { "db": "ICS CERT", "id": "ICSA-12-030-01", "trust": 3.1 }, { "db": "SIEMENS", "id": "SSA-345442", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-201202-089", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2012-0464", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2012-001316", "trust": 0.8 }, { "db": "IVD", "id": "28D0CA64-2354-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-52459", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "28d0ca64-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0464" }, { "db": "VULHUB", "id": "VHN-52459" }, { "db": "JVNDB", "id": "JVNDB-2012-001316" }, { "db": "CNNVD", "id": "CNNVD-201202-089" }, { "db": "NVD", "id": "CVE-2011-4514" } ] }, "id": "VAR-201202-0049", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "28d0ca64-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0464" }, { "db": "VULHUB", "id": "VHN-52459" } ], "trust": 1.5153960400000002 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "28d0ca64-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0464" } ] }, "last_update_date": "2024-11-23T21:46:29.740000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-345442", "trust": 0.8, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "title": "\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc", "trust": 0.8, "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx" }, { "title": "Top Page", "trust": 0.8, "url": "http://www.siemens.com/entry/jp/ja/" }, { "title": "Patch for Siemens SIMATIC WinCC HMI Telnet Vulnerability (CNVD-2012-0464)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/9062" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2012-0464" }, { "db": "JVNDB", "id": "JVNDB-2012-001316" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-287", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-52459" }, { "db": "JVNDB", "id": "JVNDB-2012-001316" }, { "db": "NVD", "id": "CVE-2011-4514" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.1, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01.pdf" }, { "trust": 1.7, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4514" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4514" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2012-0464" }, { "db": "VULHUB", "id": "VHN-52459" }, { "db": "JVNDB", "id": "JVNDB-2012-001316" }, { "db": "CNNVD", "id": "CNNVD-201202-089" }, { "db": "NVD", "id": "CVE-2011-4514" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "28d0ca64-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0464" }, { "db": "VULHUB", "id": "VHN-52459" }, { "db": "JVNDB", "id": "JVNDB-2012-001316" }, { "db": "CNNVD", "id": "CNNVD-201202-089" }, { "db": "NVD", "id": "CVE-2011-4514" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2012-02-07T00:00:00", "db": "IVD", "id": "28d0ca64-2354-11e6-abef-000c29c66e3d" }, { "date": "2012-02-07T00:00:00", "db": "CNVD", "id": "CNVD-2012-0464" }, { "date": "2012-02-03T00:00:00", "db": "VULHUB", "id": "VHN-52459" }, { "date": "2012-02-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001316" }, { "date": "2012-02-07T00:00:00", "db": "CNNVD", "id": "CNNVD-201202-089" }, { "date": "2012-02-03T20:55:01.577000", "db": "NVD", "id": "CVE-2011-4514" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2012-02-07T00:00:00", "db": "CNVD", "id": "CNVD-2012-0464" }, { "date": "2012-02-06T00:00:00", "db": "VULHUB", "id": "VHN-52459" }, { "date": "2012-02-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001316" }, { "date": "2012-02-07T00:00:00", "db": "CNNVD", "id": "CNNVD-201202-089" }, { "date": "2024-11-21T01:32:27.483000", "db": "NVD", "id": "CVE-2011-4514" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201202-089" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Siemens Product TELNET Access vulnerability in daemon", "sources": [ { "db": "JVNDB", "id": "JVNDB-2012-001316" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "authorization issue", "sources": [ { "db": "CNNVD", "id": "CNNVD-201202-089" } ], "trust": 0.6 } }
var-201905-0112
Vulnerability from variot
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. plural SIMATIC The product contains vulnerabilities related to authorization, permissions, and access control.Information may be obtained and information may be altered. Multiple Siemens Products are prone to following security vulnerabilities: 1. An information-disclosure vulnerability 2. A cross-site-scripting vulnerability 3. A security vulnerability An attacker may leverage these issues to obtain potentially sensitive information and to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and to launch other attacks. Siemens SIMATIC WinCC, etc. are all products of Siemens (Siemens) in Germany. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. Siemens SIMATIC HMI Comfort Panels is a touch panel device. Siemens SIMATIC HMI Comfort Outdoor Panels is a touch panel device specially designed for outdoor use. The vulnerability stems from the lack of effective permissions and access control measures in network systems or products
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201905-0112", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic hmi comfort outdoor panels", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic wincc runtime", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic wincc \\", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi mp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort panels", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi op", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi tp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort outdoor panels", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi comfort panels", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime professional", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15.1" }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15.1" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v15.1" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v15" }, { "model": "simatic hmi ktp mobile panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15" }, { "model": "simatic hmi comfort outdoor panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15" }, { "model": "simatic hmi classic devices", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc runtime professional update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "v15.11" }, { "model": "simatic wincc runtime advanced update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "15.11" }, { "model": "simatic wincc update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "v15.11" }, { "model": "simatic hmi ktp mobile update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "15.11" }, { "model": "simatic hmi comfort panels update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "15.11" }, { "model": "simatic hmi comfort outdoor panels update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "15.11" } ], "sources": [ { "db": "BID", "id": "108412" }, { "db": "JVNDB", "id": "JVNDB-2019-004632" }, { "db": "NVD", "id": "CVE-2019-6572" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_outdoor_panels_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_runtime_professional", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-004632" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens ProductCERT reported these vulnerabilities to NCCIC.,Siemens ProductCERT", "sources": [ { "db": "CNNVD", "id": "CNNVD-201905-590" } ], "trust": 0.6 }, "cve": "CVE-2019-6572", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 6.4, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2019-6572", "impactScore": 4.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "NONE", "baseScore": 6.4, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "VHN-158007", "impactScore": 4.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2019-6572", "impactScore": 5.2, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 9.1, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2019-6572", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2019-6572", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2019-6572", "trust": 0.8, "value": "Critical" }, { "author": "CNNVD", "id": "CNNVD-201905-590", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULHUB", "id": "VHN-158007", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-158007" }, { "db": "JVNDB", "id": "JVNDB-2019-004632" }, { "db": "CNNVD", "id": "CNNVD-201905-590" }, { "db": "NVD", "id": "CVE-2019-6572" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003c V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003c V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. plural SIMATIC The product contains vulnerabilities related to authorization, permissions, and access control.Information may be obtained and information may be altered. Multiple Siemens Products are prone to following security vulnerabilities:\n1. An information-disclosure vulnerability\n2. A cross-site-scripting vulnerability\n3. A security vulnerability\nAn attacker may leverage these issues to obtain potentially sensitive information and to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and to launch other attacks. Siemens SIMATIC WinCC, etc. are all products of Siemens (Siemens) in Germany. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. Siemens SIMATIC HMI Comfort Panels is a touch panel device. Siemens SIMATIC HMI Comfort Outdoor Panels is a touch panel device specially designed for outdoor use. The vulnerability stems from the lack of effective permissions and access control measures in network systems or products", "sources": [ { "db": "NVD", "id": "CVE-2019-6572" }, { "db": "JVNDB", "id": "JVNDB-2019-004632" }, { "db": "BID", "id": "108412" }, { "db": "VULHUB", "id": "VHN-158007" } ], "trust": 1.98 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "ICS CERT", "id": "ICSA-19-134-09", "trust": 2.8 }, { "db": "NVD", "id": "CVE-2019-6572", "trust": 2.8 }, { "db": "BID", "id": "108412", "trust": 2.0 }, { "db": "SIEMENS", "id": "SSA-804486", "trust": 1.7 }, { "db": "JVNDB", "id": "JVNDB-2019-004632", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201905-590", "trust": 0.7 }, { "db": "ICS CERT", "id": "ICSA-19-134-02", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2019.1716.2", "trust": 0.6 }, { "db": "CNVD", "id": "CNVD-2021-54367", "trust": 0.1 }, { "db": "VULHUB", "id": "VHN-158007", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-158007" }, { "db": "BID", "id": "108412" }, { "db": "JVNDB", "id": "JVNDB-2019-004632" }, { "db": "CNNVD", "id": "CNNVD-201905-590" }, { "db": "NVD", "id": "CVE-2019-6572" } ] }, "id": "VAR-201905-0112", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-158007" } ], "trust": 0.7545892989999999 }, "last_update_date": "2024-11-23T21:37:16.658000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-804486", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf" }, { "title": "Siemens SIMATIC Panels and WinCC Repair measures for trust management problem vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=92740" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-004632" }, { "db": "CNNVD", "id": "CNNVD-201905-590" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-798", "trust": 1.1 }, { "problemtype": "CWE-200", "trust": 1.0 }, { "problemtype": "CWE-264", "trust": 0.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-158007" }, { "db": "JVNDB", "id": "JVNDB-2019-004632" }, { "db": "NVD", "id": "CVE-2019-6572" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.9, "url": "http://www.securityfocus.com/bid/108412" }, { "trust": 2.5, "url": "https://www.us-cert.gov/ics/advisories/icsa-19-134-09" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-6572" }, { "trust": 0.9, "url": "http://subscriber.communications.siemens.com/" }, { "trust": 0.9, "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-134-09" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-6572" }, { "trust": 0.6, "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-134-02-0" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/simatic-wincc-multiple-vulnerabilities-29288" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/80946" } ], "sources": [ { "db": "VULHUB", "id": "VHN-158007" }, { "db": "BID", "id": "108412" }, { "db": "JVNDB", "id": "JVNDB-2019-004632" }, { "db": "CNNVD", "id": "CNNVD-201905-590" }, { "db": "NVD", "id": "CVE-2019-6572" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-158007" }, { "db": "BID", "id": "108412" }, { "db": "JVNDB", "id": "JVNDB-2019-004632" }, { "db": "CNNVD", "id": "CNNVD-201905-590" }, { "db": "NVD", "id": "CVE-2019-6572" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-05-14T00:00:00", "db": "VULHUB", "id": "VHN-158007" }, { "date": "2019-05-14T00:00:00", "db": "BID", "id": "108412" }, { "date": "2019-06-05T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-004632" }, { "date": "2019-05-14T00:00:00", "db": "CNNVD", "id": "CNNVD-201905-590" }, { "date": "2019-05-14T20:29:04.200000", "db": "NVD", "id": "CVE-2019-6572" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-10-06T00:00:00", "db": "VULHUB", "id": "VHN-158007" }, { "date": "2019-05-14T00:00:00", "db": "BID", "id": "108412" }, { "date": "2019-07-09T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-004632" }, { "date": "2020-10-28T00:00:00", "db": "CNNVD", "id": "CNNVD-201905-590" }, { "date": "2024-11-21T04:46:43.653000", "db": "NVD", "id": "CVE-2019-6572" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201905-590" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural SIMATIC Vulnerabilities related to authorization, authority, and access control in products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-004632" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "trust management problem", "sources": [ { "db": "CNNVD", "id": "CNNVD-201905-590" } ], "trust": 0.6 } }
var-201904-0176
Vulnerability from variot
A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication. plural Siemens The product contains an input validation vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. Siemens is a leading global technology company that provides solutions to customers in the areas of power generation and transmission and distribution, infrastructure, industrial automation, drive and software with innovation in electrification, automation and digital. Siemens has a denial of service vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens SIMATIC S7-1500 CPU, etc. are all products of German Siemens (Siemens). SIMATIC S7-1500 CPU is a CPU (central processing unit) module. SIMATIC S7-1500 is a programmable logic controller. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. The vulnerability stems from the failure of the network system or product to properly validate the input data
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201904-0176", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic wincc runtime advanced", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic net pc software", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic rf188c", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic rf600r", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic ipc diagmonitor", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic hmi comfort outdoor panels", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic s7-1500t", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "2.5" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic et 200 open controller cpu 1515sp pc2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.7" }, { "model": "simatic rf188c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic wincc oa", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.15-p018" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic ipc diagmonitor", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic wincc runtime mobile", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-1500s", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "2.5" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinec-nms", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "1.0" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic cp443-1 opc ua", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic rf600r", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-1500", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "2.5" }, { "model": "sinec-nms", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.0" }, { "model": "simatic s7-1500f", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "2.5" }, { "model": "sinema server", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic net pc software", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinumerik opc ua server", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic wincc runtime comfort", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "opc unified architecture", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-1500 software controller", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "2.5" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "telecontrol server basic", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.1.1" }, { "model": "simatic wincc runtime hsp comfort", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic cp 443-1 opc-ua", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic et 200 open controller cpu 1515sp pc2", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 software controller", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc oa", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu family", "scope": "lte", "trust": 0.6, "vendor": "siemens", "version": "\u003c=v2.5" }, { "model": "simatic s7-1500 software controller", "scope": "lte", "trust": 0.6, "vendor": "siemens", "version": "\u003c=v2.5" }, { "model": "simatic wincc oa \u003cv3.15-p018", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinema server", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinumerik opc ua server", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v2.1" }, { "model": "telecontrol server basics", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime comfort", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime mobile", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinec-nms", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic cp443-1 opc ua", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic et200 open controller cpu 1515sp pc2", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime hsp comfort", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "telecontrol server basic", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "3.1" }, { "model": "telecontrol server basic sp2", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "3.0" }, { "model": "telecontrol server basic", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "3.0" }, { "model": "sinumerik opc ua server", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sinema server", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sinec-nms", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc runtime mobile", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc runtime hsp comfort", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc runtime comfort", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc oa", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "3.15" }, { "model": "simatic wincc oa 3.14-p021", "scope": null, "trust": 0.3, "vendor": "siemens", "version": null }, { "model": "simatic wincc oa", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "3.14" }, { "model": "simatic wincc oa p002", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "3.12" }, { "model": "simatic wincc oa", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "3.12" }, { "model": "simatic s7-1500 software controller", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1.7" }, { "model": "simatic s7-1500 software controller", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2.5" }, { "model": "simatic s7-1500 software controller", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2.0" }, { "model": "simatic s7-1500", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1.8.5" }, { "model": "simatic s7-1500", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1.8.3" }, { "model": "simatic s7-1500", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1.7" }, { "model": "simatic s7-1500", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2.5" }, { "model": "simatic s7-1500", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2.0" }, { "model": "simatic s7-1500", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1.6" }, { "model": "simatic s7-1500", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1.5.0" }, { "model": "simatic rf600r", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic rf188c", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic net pc software", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic ipc diagmonitor", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic et200 open controller cpu 1515sp pc2", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic cp opc ua", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "443-10" }, { "model": "sinumerik opc ua server", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "2.1" }, { "model": "simatic wincc oa 3.15-p018", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp443 1 opc ua", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500s", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500t", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200 open controller cpu 1515sp pc2", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic ipc diagmonitor", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic net pc", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf188c", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf600r", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500 controller", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic wincc oa", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic wincc runtime advanced", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic wincc runtime comfort", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic wincc runtime hsp comfort", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic wincc runtime mobile", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinec nms", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinema server", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinumerik opc ua server", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "telecontrol server basic", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500f", "version": "*" } ], "sources": [ { "db": "IVD", "id": "b72b932a-ffe5-40c4-80a7-5e3f71b449fc" }, { "db": "CNVD", "id": "CNVD-2019-12905" }, { "db": "BID", "id": "107833" }, { "db": "JVNDB", "id": "JVNDB-2019-003488" }, { "db": "NVD", "id": "CVE-2019-6575" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:siemens:simatic_cp_443-1_std_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_et_200_open_controller_cpu_1515sp_pc2_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_ipc_diagmonitor_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_net_pc-software", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_rf188c_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_rf600r_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_s7-1500_software_controller_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_s7-1500_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_open_architecture", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-003488" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens,Siemens ProductCERT reported this vulnerability to NCCIC.", "sources": [ { "db": "CNNVD", "id": "CNNVD-201904-462" } ], "trust": 0.6 }, "cve": "CVE-2019-6575", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2019-6575", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2019-12905", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "b72b932a-ffe5-40c4-80a7-5e3f71b449fc", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-158010", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2019-6575", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2019-6575", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2019-6575", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2019-6575", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2019-12905", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201904-462", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "b72b932a-ffe5-40c4-80a7-5e3f71b449fc", "trust": 0.2, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-158010", "trust": 0.1, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2019-6575", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "IVD", "id": "b72b932a-ffe5-40c4-80a7-5e3f71b449fc" }, { "db": "CNVD", "id": "CNVD-2019-12905" }, { "db": "VULHUB", "id": "VHN-158010" }, { "db": "VULMON", "id": "CVE-2019-6575" }, { "db": "JVNDB", "id": "JVNDB-2019-003488" }, { "db": "CNNVD", "id": "CNNVD-201904-462" }, { "db": "NVD", "id": "CVE-2019-6575" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V2.7), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions \u003c V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions \u003c V1.1.0), SIMATIC RF600R family (All versions \u003c V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.5 \u003c V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions \u003c V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Upd 4), SINEC NMS (All versions \u003c V1.0 SP1), SINEMA Server (All versions \u003c V14 SP2), SINUMERIK OPC UA Server (All versions \u003c V2.1), TeleControl Server Basic (All versions \u003c V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication. plural Siemens The product contains an input validation vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. Siemens is a leading global technology company that provides solutions to customers in the areas of power generation and transmission and distribution, infrastructure, industrial automation, drive and software with innovation in electrification, automation and digital. Siemens has a denial of service vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens SIMATIC S7-1500 CPU, etc. are all products of German Siemens (Siemens). SIMATIC S7-1500 CPU is a CPU (central processing unit) module. SIMATIC S7-1500 is a programmable logic controller. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. The vulnerability stems from the failure of the network system or product to properly validate the input data", "sources": [ { "db": "NVD", "id": "CVE-2019-6575" }, { "db": "JVNDB", "id": "JVNDB-2019-003488" }, { "db": "CNVD", "id": "CNVD-2019-12905" }, { "db": "BID", "id": "107833" }, { "db": "IVD", "id": "b72b932a-ffe5-40c4-80a7-5e3f71b449fc" }, { "db": "VULHUB", "id": "VHN-158010" }, { "db": "VULMON", "id": "CVE-2019-6575" } ], "trust": 2.79 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-6575", "trust": 3.7 }, { "db": "ICS CERT", "id": "ICSA-19-099-03", "trust": 2.4 }, { "db": "SIEMENS", "id": "SSA-307392", "trust": 1.8 }, { "db": "BID", "id": "107833", "trust": 1.1 }, { "db": "CNNVD", "id": "CNNVD-201904-462", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2019-12905", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2019-003488", "trust": 0.8 }, { "db": "AUSCERT", "id": "ESB-2019.1205", "trust": 0.6 }, { "db": "IVD", "id": "B72B932A-FFE5-40C4-80A7-5E3F71B449FC", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-158010", "trust": 0.1 }, { "db": "VULMON", "id": "CVE-2019-6575", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "b72b932a-ffe5-40c4-80a7-5e3f71b449fc" }, { "db": "CNVD", "id": "CNVD-2019-12905" }, { "db": "VULHUB", "id": "VHN-158010" }, { "db": "VULMON", "id": "CVE-2019-6575" }, { "db": "BID", "id": "107833" }, { "db": "JVNDB", "id": "JVNDB-2019-003488" }, { "db": "CNNVD", "id": "CNNVD-201904-462" }, { "db": "NVD", "id": "CVE-2019-6575" } ] }, "id": "VAR-201904-0176", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "b72b932a-ffe5-40c4-80a7-5e3f71b449fc" }, { "db": "CNVD", "id": "CNVD-2019-12905" }, { "db": "VULHUB", "id": "VHN-158010" } ], "trust": 1.5723463029411764 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS", "Network device" ], "sub_category": null, "trust": 0.6 }, { "category": [ "ICS" ], "sub_category": null, "trust": 0.2 } ], "sources": [ { "db": "IVD", "id": "b72b932a-ffe5-40c4-80a7-5e3f71b449fc" }, { "db": "CNVD", "id": "CNVD-2019-12905" } ] }, "last_update_date": "2024-11-23T22:45:04.929000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-307392", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf" }, { "title": "SiemensIndustrialProductswithOPCUA denial of service vulnerability patch", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/160239" }, { "title": "Siemens OPC UA Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=91290" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=f300e0ed579e6a7eeebba4d6b8703ede" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-12905" }, { "db": "VULMON", "id": "CVE-2019-6575" }, { "db": "JVNDB", "id": "JVNDB-2019-003488" }, { "db": "CNNVD", "id": "CNNVD-201904-462" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-755", "trust": 1.1 }, { "problemtype": "CWE-248", "trust": 1.0 }, { "problemtype": "CWE-20", "trust": 0.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-158010" }, { "db": "JVNDB", "id": "JVNDB-2019-003488" }, { "db": "NVD", "id": "CVE-2019-6575" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-099-03" }, { "trust": 1.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-6575" }, { "trust": 0.9, "url": "http://www.siemens.com/" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-6575" }, { "trust": 0.7, "url": "https://www.securityfocus.com/bid/107833" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/siemens-simatic-denial-of-service-via-opc-ua-4840-tcp-28974" }, { "trust": 0.6, "url": "https://www.us-cert.gov/ics/advisories/icsa-19-099-03" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/78742" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/755.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-19-099-03" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-12905" }, { "db": "VULHUB", "id": "VHN-158010" }, { "db": "VULMON", "id": "CVE-2019-6575" }, { "db": "BID", "id": "107833" }, { "db": "JVNDB", "id": "JVNDB-2019-003488" }, { "db": "CNNVD", "id": "CNNVD-201904-462" }, { "db": "NVD", "id": "CVE-2019-6575" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "b72b932a-ffe5-40c4-80a7-5e3f71b449fc" }, { "db": "CNVD", "id": "CNVD-2019-12905" }, { "db": "VULHUB", "id": "VHN-158010" }, { "db": "VULMON", "id": "CVE-2019-6575" }, { "db": "BID", "id": "107833" }, { "db": "JVNDB", "id": "JVNDB-2019-003488" }, { "db": "CNNVD", "id": "CNNVD-201904-462" }, { "db": "NVD", "id": "CVE-2019-6575" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-05-05T00:00:00", "db": "IVD", "id": "b72b932a-ffe5-40c4-80a7-5e3f71b449fc" }, { "date": "2019-05-05T00:00:00", "db": "CNVD", "id": "CNVD-2019-12905" }, { "date": "2019-04-17T00:00:00", "db": "VULHUB", "id": "VHN-158010" }, { "date": "2019-04-17T00:00:00", "db": "VULMON", "id": "CVE-2019-6575" }, { "date": "2019-04-09T00:00:00", "db": "BID", "id": "107833" }, { "date": "2019-05-17T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-003488" }, { "date": "2019-04-09T00:00:00", "db": "CNNVD", "id": "CNNVD-201904-462" }, { "date": "2019-04-17T14:29:03.760000", "db": "NVD", "id": "CVE-2019-6575" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-05-07T00:00:00", "db": "CNVD", "id": "CNVD-2019-12905" }, { "date": "2020-10-16T00:00:00", "db": "VULHUB", "id": "VHN-158010" }, { "date": "2022-04-12T00:00:00", "db": "VULMON", "id": "CVE-2019-6575" }, { "date": "2019-04-09T00:00:00", "db": "BID", "id": "107833" }, { "date": "2019-05-17T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-003488" }, { "date": "2022-08-11T00:00:00", "db": "CNNVD", "id": "CNNVD-201904-462" }, { "date": "2024-11-21T04:46:43.960000", "db": "NVD", "id": "CVE-2019-6575" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201904-462" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens Industrial Products with OPC UA Denial of service vulnerability", "sources": [ { "db": "IVD", "id": "b72b932a-ffe5-40c4-80a7-5e3f71b449fc" }, { "db": "CNVD", "id": "CNVD-2019-12905" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Input validation error", "sources": [ { "db": "IVD", "id": "b72b932a-ffe5-40c4-80a7-5e3f71b449fc" }, { "db": "CNNVD", "id": "CNNVD-201904-462" } ], "trust": 0.8 } }
var-202409-0270
Vulnerability from variot
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-7 LTE (All versions < V3.5.20), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.5.20), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC WinCC Runtime Advanced (All versions), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.4.8). The web server of the affected devices do not properly handle certain errors when using the Expect HTTP request header, resulting in NULL dereference.
This could allow a remote attacker with no privileges to cause a denial of service condition in the system. SIMATIC CP 1242 and CP 1243 related processors connect SIMATIC S7-1200 controllers to wide area networks (WANs). They offer integrated security features such as firewalls, virtual private networks (VPNs) and support for other data encryption protocols. SIMATIC HMI Panels are used for operator control and monitoring of machines and plants. SIMATIC IPC DiagBase diagnostics software allows early identification of any potential faults on SIMATIC industrial computers and helps to avoid or reduce system downtime. SIMATIC IPC DiagMonitor monitors, reports, visualizes and logs the system status of SIMATIC IPCs. It communicates with other systems and reacts when events occur. Communication processor (CP) modules SIMATIC TIM 3V-IE and TIM 4R-IE are designed to enable Ethernet or telecontrol communication for SIMATIC S7-300/S7-400 CPUs. SIMATIC WinCC Runtime Advanced is a visualization runtime platform for operator control and monitoring of machines and plants. SIPLUS extreme products are designed for reliable operation under extreme conditions and are based on SIMATIC, LOGO!, SITOP, SINAMICS, SIMOTION, SCALANCE or other devices. SIPLUS devices use the same firmware as the products they are based on.
Siemens Industrial products have a null pointer dereference vulnerability
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202409-0270", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic ipc diagmonitor", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic ipc diagbase", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "siplus tim irc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1531\u003cv2.4.8" }, { "model": "tim irc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1531\u003cv2.4.8" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1242-7v2\u003cv3.5.20" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1243-1\u003cv3.5.20" }, { "model": "simatic cp dnp3", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1243-1\u003cv3.5.20" }, { "model": "simatic cp iec", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1243-1\u003cv3.5.20" }, { "model": "simatic cp lte", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1243-7\u003cv3.5.20" }, { "model": "simatic cp irc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1243-8\u003cv3.5.20" }, { "model": "simatic hmi comfort panels", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-38015" } ] }, "cve": "CVE-2023-30756", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "HIGH", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 5.4, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 4.9, "id": "CNVD-2024-38015", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:H/Au:N/C:C/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "HIGH", "attackVector": "NETWORK", "author": "productcert@siemens.com", "availabilityImpact": "HIGH", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 2.2, "id": "CVE-2023-30756", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } ], "severity": [ { "author": "productcert@siemens.com", "id": "CVE-2023-30756", "trust": 1.0, "value": "High" }, { "author": "CNVD", "id": "CNVD-2024-38015", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-38015" }, { "db": "NVD", "id": "CVE-2023-30756" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-7 LTE (All versions \u003c V3.5.20), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.5.20), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC WinCC Runtime Advanced (All versions), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.4.8). The web server of the affected devices do not properly handle certain errors when using the Expect HTTP request header, resulting in NULL dereference. \r\n\r\nThis could allow a remote attacker with no privileges to cause a denial of service condition in the system. SIMATIC CP 1242 and CP 1243 related processors connect SIMATIC S7-1200 controllers to wide area networks (WANs). They offer integrated security features such as firewalls, virtual private networks (VPNs) and support for other data encryption protocols. SIMATIC HMI Panels are used for operator control and monitoring of machines and plants. SIMATIC IPC DiagBase diagnostics software allows early identification of any potential faults on SIMATIC industrial computers and helps to avoid or reduce system downtime. SIMATIC IPC DiagMonitor monitors, reports, visualizes and logs the system status of SIMATIC IPCs. It communicates with other systems and reacts when events occur. Communication processor (CP) modules SIMATIC TIM 3V-IE and TIM 4R-IE are designed to enable Ethernet or telecontrol communication for SIMATIC S7-300/S7-400 CPUs. SIMATIC WinCC Runtime Advanced is a visualization runtime platform for operator control and monitoring of machines and plants. SIPLUS extreme products are designed for reliable operation under extreme conditions and are based on SIMATIC, LOGO!, SITOP, SINAMICS, SIMOTION, SCALANCE or other devices. SIPLUS devices use the same firmware as the products they are based on. \n\nSiemens Industrial products have a null pointer dereference vulnerability", "sources": [ { "db": "NVD", "id": "CVE-2023-30756" }, { "db": "CNVD", "id": "CNVD-2024-38015" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "SIEMENS", "id": "SSA-423808", "trust": 1.6 }, { "db": "NVD", "id": "CVE-2023-30756", "trust": 1.6 }, { "db": "CNVD", "id": "CNVD-2024-38015", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-38015" }, { "db": "NVD", "id": "CVE-2023-30756" } ] }, "id": "VAR-202409-0270", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-38015" } ], "trust": 1.364781105 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-38015" } ] }, "last_update_date": "2024-09-13T23:28:46.292000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens Industrial Products Null Pointer Dereference Vulnerability (CNVD-2024-38015)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/590311" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-38015" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-476", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2023-30756" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-423808.html" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-38015" }, { "db": "NVD", "id": "CVE-2023-30756" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-38015" }, { "db": "NVD", "id": "CVE-2023-30756" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-09-12T00:00:00", "db": "CNVD", "id": "CNVD-2024-38015" }, { "date": "2024-09-10T10:15:06.197000", "db": "NVD", "id": "CVE-2023-30756" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-09-12T00:00:00", "db": "CNVD", "id": "CNVD-2024-38015" }, { "date": "2024-09-10T12:09:50.377000", "db": "NVD", "id": "CVE-2023-30756" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens Industrial Products Null Pointer Dereference Vulnerability (CNVD-2024-38015)", "sources": [ { "db": "CNVD", "id": "CNVD-2024-38015" } ], "trust": 0.6 } }
var-201904-0174
Vulnerability from variot
The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device.
The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. Multiple Siemens products contain input validation vulnerabilities.Service operation interruption (DoS) There is a possibility of being put into a state. SiemensCP, SIAMTIC, SIMOCODE, SINAMICS, SITOP and TIM are all devices manufactured by Siemens. Multiple Siemens products are prone to an unspecified denial-of-service vulnerability. Attackers can exploit this issue to cause a denial-of-service condition, denying service to legitimate users. A vulnerability has been identified in CP1604, CP1616, SIMATIC CP343-1 Advanced, SIMATIC CP443-1, SIMATIC CP443-1 Advanced, SIMATIC CP443-1 OPC UA, SIMATIC ET 200 SP Open Controller CPU 1515SP PC, SIMATIC ET 200 SP Open Controller CPU 1515SP PC2, SIMATIC HMI Comfort Outdoor Panels 7" & 15", SIMATIC HMI Comfort Panels 4" - 22", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC IPC DiagMonitor, SIMATIC RF181-EIP, SIMATIC RF182C, SIMATIC RF185C, SIMATIC RF186C, SIMATIC RF188C, SIMATIC RF600R, SIMATIC S7-1500 CPU family, SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU family, SIMATIC S7-400 PN (incl. F) V6 and below, SIMATIC S7-400 PN/DP V7 (incl. F), SIMATIC S7-PLCSIM Advanced, SIMATIC Teleservice Adapter IE Advanced, SIMATIC Teleservice Adapter IE Basic, SIMATIC Teleservice Adapter IE Standard, SIMATIC WinAC RTX (F) 2010, SIMATIC WinCC Runtime Advanced, SIMOCODE pro V EIP, SIMOCODE pro V PN, SINAMICS G130 V4.6 (Control Unit), SINAMICS G130 V4.7 (Control Unit), SINAMICS G130 V4.7 SP1 (Control Unit), SINAMICS G130 V4.8 (Control Unit), SINAMICS G130 V5.1 (Control Unit), SINAMICS G130 V5.1 SP1 (Control Unit), SINAMICS G150 V4.6 (Control Unit), SINAMICS G150 V4.7 (Control Unit), SINAMICS G150 V4.7 SP1 (Control Unit), SINAMICS G150 V4.8 (Control Unit), SINAMICS G150 V5.1 (Control Unit), SINAMICS G150 V5.1 SP1 (Control Unit), SINAMICS GH150 V4.7 (Control Unit), SINAMICS GH150 V4.8 (Control Unit), SINAMICS GL150 V4.7 (Control Unit), SINAMICS GL150 V4.8 (Control Unit), SINAMICS GM150 V4.7 (Control Unit), SINAMICS GM150 V4.8 (Control Unit), SINAMICS S120 V4.6 (Control Unit), SINAMICS S120 V4.7 (Control Unit), SINAMICS S120 V4.7 SP1 (Control Unit), SINAMICS S120 V4.8 (Control Unit), SINAMICS S120 V5.1 (Control Unit), SINAMICS S120 V5.1 SP1 (Control Unit), SINAMICS S150 V4.6 (Control Unit), SINAMICS S150 V4.7 (Control Unit), SINAMICS S150 V4.7 SP1 (Control Unit), SINAMICS S150 V4.8 (Control Unit), SINAMICS S150 V5.1 (Control Unit), SINAMICS S150 V5.1 SP1 (Control Unit), SINAMICS S210 V5.1 (Control Unit), SINAMICS S210 V5.1 SP1 (Control Unit), SINAMICS SL150 V4.7 (Control Unit), SINAMICS SL150 V4.8 (Control Unit), SINAMICS SM120 V4.7 (Control Unit), SINAMICS SM120 V4.8 (Control Unit), SINAMICS SM150 V4.8 (Control Unit), SITOP Manager, SITOP PSU8600, SITOP UPS1600, TIM 1531 IRC. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens SIMATIC S7-1500 CPU, etc. are all products of German Siemens (Siemens). SIMATIC S7-1500 CPU is a CPU (central processing unit) module. CP1616 is a communications processor. SIMATIC S7-1500 is a programmable logic controller. The vulnerability stems from the failure of the network system or product to properly validate the input data
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201904-0174", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "sinamics s210", "scope": "eq", "trust": 1.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics s150", "scope": "eq", "trust": 1.3, "vendor": "siemens", "version": "5.1" }, { "model": "simatic hmi comfort outdoor panels", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics sm120", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic s7-plcsim advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "simatic ipc diagmonitor", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.1.3" }, { "model": "simatic s7-1500s", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.6.1" }, { "model": "sinamics gh150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic wincc runtime advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gl150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic s7-400 pn", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simocode pro v pn", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.1.3" }, { "model": "sinamics gm150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic s7-1500", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.6.1" }, { "model": "simatic cp443-1 advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics sl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "sitop manager", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.1" }, { "model": "sinamics sm120", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic hmi comfort panels", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic et 200 sp open controller cpu 1515sp pc2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.7" }, { "model": "sinamics g130", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2" }, { "model": "cp1604", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic winac rtx", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2010" }, { "model": "sinamics s120", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2" }, { "model": "sitop psu8600", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.5" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic cp443-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simocode pro v eip", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.1.3" }, { "model": "simatic s7-plcsim advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "simatic s7-400 pn\\/dp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sitop ups1600", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3" }, { "model": "simatic s7-1500 software controller", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.7" }, { "model": "sinamics sm150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.1" }, { "model": "simatic rf182c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic rf600r", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.2.1" }, { "model": "cp1616", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic teleservice adapter ie standard", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic rf185c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.1.0" }, { "model": "simatic rf186c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.1.0" }, { "model": "simatic hmi comfort outdoor panels", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic teleservice adapter ie basic", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gm150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic s7-1500t", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.6.1" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic s7-300", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.17" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gh150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic rf188c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.1.0" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic et 200 sp open controller cpu 1515sp pc", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.1.6" }, { "model": "sinamics g150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2" }, { "model": "sinamics s150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.1" }, { "model": "simatic winac rtx", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2010" }, { "model": "sinamics sl150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic cp443-1 opc ua", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics sm150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "5.1" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic rf181-eip", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "tim 1531 irc", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.1" }, { "model": "simatic s7-1500f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.6.1" }, { "model": "simatic cp343-1 advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics s210", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.1" }, { "model": "simatic teleservice adapter ie advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic cp 1543sp-1", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 1604", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 1616", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 343-1 advanced", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 443-1 adv", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 443-1", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic et 200 sp open controller cpu 1515sp pc", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic et 200 sp open controller cpu 1515sp pc2", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi comfort outdoor panels", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi comfort panels", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic rf185c", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": null, "scope": "eq", "trust": 0.6, "vendor": "sinamics s150", "version": "5.1" }, { "model": "simatic winac rtx sp2 all", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "2010" }, { "model": "simatic s7-300 cpu family all", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic s7-400 pn/dp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v7" }, { "model": "simatic s7-1500 software controller", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics s120", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics g130 and g150", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic rf182c", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic cp443-1 opc ua", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic ipc diagmonitor", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic rf188c", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic rf600r", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "cp1604", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "cp1616", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic et sp open controller cpu 1515sp pc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "200\u003cv2.1.6" }, { "model": "simatic hmi comfort panels 4\" 22\"", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic s7-400 pn", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v6" }, { "model": "sinamics s150", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics s210", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v5.1" }, { "model": "sinamics s210 sp1", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v5.1" }, { "model": "tim irc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1531" }, { "model": "simatic hmi comfort outdoor panels 7\" \u0026 15\"", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic rf181-eip", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic rf186c", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic s7-plcsim advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic teleservice adapter ie advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic teleservice adapter ie basic", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic teleservice adapter ie standard", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simocode pro eip", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v" }, { "model": "simocode pro pn", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v" }, { "model": "sitop manager", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sitop psu8600", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sitop ups1600", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "siamtic rf185c", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic cp343-1 advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic cp443-1", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic cp443-1 advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic et sp open controller cpu 1515sp pc2", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "200" }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "sinamics s210", "version": "5.1" }, { "model": "tim irc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15310" }, { "model": "sitop ups1600", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sitop psu8600", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sitop manager", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sinamics s210 sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics s150 sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics s150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics s150 sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics s150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics s150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.6" }, { "model": "sinamics s120 sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics s120", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics s120", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics s120 sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics s120", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics s120", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.6" }, { "model": "sinamics g150 sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics g150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics g150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics g150 sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics g150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics g150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.6" }, { "model": "sinamics g130 sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics g130", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics g130", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics g130 sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics g130", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics g130", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.6" }, { "model": "simocode pro pn", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v0" }, { "model": "simocode pro eip", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v0" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic winac rtx", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "20100" }, { "model": "simatic teleservice adapter ie standard", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic teleservice adapter ie basic", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic teleservice adapter ie advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic s7-plcsim advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic s7-400 pn/dp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "7" }, { "model": "simatic s7-400 pn", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v60" }, { "model": "simatic s7-300 cpu", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic s7-1500 software controller", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic s7-1500 cpu", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic rf600r", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic rf188c", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic rf186c", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic rf185c", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic rf182c", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic ipc diagmonitor", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi ktp900f mobile", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi ktp900 mobile", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi ktp700f mobile", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi ktp700 mobile", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi ktp400f mobile", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi ktp mobile panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi comfort outdoor panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic et200 open controller cpu 1515sp pc2", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic et200 open controller cpu 1515sp pc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic cp opc ua", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "443-10" }, { "model": "simatic cp advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "443-10" }, { "model": "simatic cp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "443-10" }, { "model": "simatic cp advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "343-10" }, { "model": "rfid 181-eip", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "cp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "16160" }, { "model": "cp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "16040" }, { "model": "sinamics s150 sp1 hf4", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics s150 hf6", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics s120 sp1 hf4", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics s120 hf6", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics g150 sp1 hf4", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics g150 hf6", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics g130 sp1 hf4", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics g130 hf6", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "simatic s7-300 cpu", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "v3.x.16" }, { "model": "simatic et200 open controller cpu 1515sp pc", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "2.1.6" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "cp1604", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi comfort panels", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi ktp mobile panels ktp400f", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi ktp mobile panels ktp700", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi ktp mobile panels ktp700f", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi ktp mobile panels ktp900", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi ktp mobile panels ktp900f", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp443 1 opc ua", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic ipc diagmonitor", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500 controller", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 plcsim advanced", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic wincc runtime advanced", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sitop manager", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf600r", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf188c", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf186c", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "cp1616", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf182c", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf181 eip", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 300", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 400 pn", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 400 pn dp", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic teleservice adapter ie advanced", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic teleservice adapter ie basic", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic teleservice adapter ie standard", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic winac rtx 2010", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf185c", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simocode pro v eip", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simocode pro v pn", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics g130", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics g150", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics s120", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics s150", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics s210", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sitop psu8600", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sitop ups1600", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "tim 1531 irc", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp343 1 advanced", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500f", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500s", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500t", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp443 1", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp443 1 advanced", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200 sp open controller cpu 1515sp pc", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200 sp open controller cpu 1515sp pc2", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi comfort outdoor panels", "version": "*" } ], "sources": [ { "db": "IVD", "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12" }, { "db": "CNVD", "id": "CNVD-2019-12904" }, { "db": "BID", "id": "107842" }, { "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "db": "NVD", "id": "CVE-2019-6568" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:siemens:simatic_cp_1604_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_1616_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp343-1_advanced_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_443-1_adv_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_443-1_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc2_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_outdoor_panels_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_rf185c_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-003541" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported this vulnerability to NCCIC.", "sources": [ { "db": "CNNVD", "id": "CNNVD-201904-458" } ], "trust": 0.6 }, "cve": "CVE-2019-6568", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2019-6568", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2019-12904", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-158003", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2019-6568", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2019-6568", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2019-6568", "trust": 1.0, "value": "HIGH" }, { "author": "productcert@siemens.com", "id": "CVE-2019-6568", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2019-6568", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2019-12904", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201904-458", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12", "trust": 0.2, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-158003", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "IVD", "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12" }, { "db": "CNVD", "id": "CNVD-2019-12904" }, { "db": "VULHUB", "id": "VHN-158003" }, { "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "db": "CNNVD", "id": "CNNVD-201904-458" }, { "db": "NVD", "id": "CVE-2019-6568" }, { "db": "NVD", "id": "CVE-2019-6568" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "The webserver of the affected devices contains a vulnerability that may lead to\r\na denial of service condition. An attacker may cause a denial of service\r\nsituation which leads to a restart of the webserver of the affected device. \r\n\r\nThe security vulnerability could be exploited by an attacker with network\r\naccess to the affected systems. Successful exploitation requires no system\r\nprivileges and no user interaction. An attacker could use the vulnerability\r\nto compromise availability of the device. Multiple Siemens products contain input validation vulnerabilities.Service operation interruption (DoS) There is a possibility of being put into a state. SiemensCP, SIAMTIC, SIMOCODE, SINAMICS, SITOP and TIM are all devices manufactured by Siemens. Multiple Siemens products are prone to an unspecified denial-of-service vulnerability. \nAttackers can exploit this issue to cause a denial-of-service condition, denying service to legitimate users. A vulnerability has been identified in CP1604, CP1616, SIMATIC CP343-1 Advanced, SIMATIC CP443-1, SIMATIC CP443-1 Advanced, SIMATIC CP443-1 OPC UA, SIMATIC ET 200 SP Open Controller CPU 1515SP PC, SIMATIC ET 200 SP Open Controller CPU 1515SP PC2, SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\", SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC IPC DiagMonitor, SIMATIC RF181-EIP, SIMATIC RF182C, SIMATIC RF185C, SIMATIC RF186C, SIMATIC RF188C, SIMATIC RF600R, SIMATIC S7-1500 CPU family, SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU family, SIMATIC S7-400 PN (incl. F) V6 and below, SIMATIC S7-400 PN/DP V7 (incl. F), SIMATIC S7-PLCSIM Advanced, SIMATIC Teleservice Adapter IE Advanced, SIMATIC Teleservice Adapter IE Basic, SIMATIC Teleservice Adapter IE Standard, SIMATIC WinAC RTX (F) 2010, SIMATIC WinCC Runtime Advanced, SIMOCODE pro V EIP, SIMOCODE pro V PN, SINAMICS G130 V4.6 (Control Unit), SINAMICS G130 V4.7 (Control Unit), SINAMICS G130 V4.7 SP1 (Control Unit), SINAMICS G130 V4.8 (Control Unit), SINAMICS G130 V5.1 (Control Unit), SINAMICS G130 V5.1 SP1 (Control Unit), SINAMICS G150 V4.6 (Control Unit), SINAMICS G150 V4.7 (Control Unit), SINAMICS G150 V4.7 SP1 (Control Unit), SINAMICS G150 V4.8 (Control Unit), SINAMICS G150 V5.1 (Control Unit), SINAMICS G150 V5.1 SP1 (Control Unit), SINAMICS GH150 V4.7 (Control Unit), SINAMICS GH150 V4.8 (Control Unit), SINAMICS GL150 V4.7 (Control Unit), SINAMICS GL150 V4.8 (Control Unit), SINAMICS GM150 V4.7 (Control Unit), SINAMICS GM150 V4.8 (Control Unit), SINAMICS S120 V4.6 (Control Unit), SINAMICS S120 V4.7 (Control Unit), SINAMICS S120 V4.7 SP1 (Control Unit), SINAMICS S120 V4.8 (Control Unit), SINAMICS S120 V5.1 (Control Unit), SINAMICS S120 V5.1 SP1 (Control Unit), SINAMICS S150 V4.6 (Control Unit), SINAMICS S150 V4.7 (Control Unit), SINAMICS S150 V4.7 SP1 (Control Unit), SINAMICS S150 V4.8 (Control Unit), SINAMICS S150 V5.1 (Control Unit), SINAMICS S150 V5.1 SP1 (Control Unit), SINAMICS S210 V5.1 (Control Unit), SINAMICS S210 V5.1 SP1 (Control Unit), SINAMICS SL150 V4.7 (Control Unit), SINAMICS SL150 V4.8 (Control Unit), SINAMICS SM120 V4.7 (Control Unit), SINAMICS SM120 V4.8 (Control Unit), SINAMICS SM150 V4.8 (Control Unit), SITOP Manager, SITOP PSU8600, SITOP UPS1600, TIM 1531 IRC. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens SIMATIC S7-1500 CPU, etc. are all products of German Siemens (Siemens). SIMATIC S7-1500 CPU is a CPU (central processing unit) module. CP1616 is a communications processor. SIMATIC S7-1500 is a programmable logic controller. The vulnerability stems from the failure of the network system or product to properly validate the input data", "sources": [ { "db": "NVD", "id": "CVE-2019-6568" }, { "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "db": "CNVD", "id": "CNVD-2019-12904" }, { "db": "BID", "id": "107842" }, { "db": "IVD", "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12" }, { "db": "VULHUB", "id": "VHN-158003" } ], "trust": 2.7 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-6568", "trust": 3.6 }, { "db": "ICS CERT", "id": "ICSA-19-099-06", "trust": 2.3 }, { "db": "SIEMENS", "id": "SSA-480230", "trust": 2.0 }, { "db": "SIEMENS", "id": "SSA-530931", "trust": 1.7 }, { "db": "ICS CERT", "id": "ICSA-19-227-04", "trust": 1.4 }, { "db": "BID", "id": "107842", "trust": 1.0 }, { "db": "CNNVD", "id": "CNNVD-201904-458", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2019-12904", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2019-003541", "trust": 0.8 }, { "db": "AUSCERT", "id": "ESB-2019.3150", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2019.1204.2", "trust": 0.6 }, { "db": "IVD", "id": "A397CC8B-EE17-4FAF-8447-E9EE5F57DD12", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-158003", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12" }, { "db": "CNVD", "id": "CNVD-2019-12904" }, { "db": "VULHUB", "id": "VHN-158003" }, { "db": "BID", "id": "107842" }, { "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "db": "CNNVD", "id": "CNNVD-201904-458" }, { "db": "NVD", "id": "CVE-2019-6568" } ] }, "id": "VAR-201904-0174", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12" }, { "db": "CNVD", "id": "CNVD-2019-12904" }, { "db": "VULHUB", "id": "VHN-158003" } ], "trust": 1.5998432480392157 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS", "Network device" ], "sub_category": null, "trust": 0.6 }, { "category": [ "ICS" ], "sub_category": null, "trust": 0.2 } ], "sources": [ { "db": "IVD", "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12" }, { "db": "CNVD", "id": "CNVD-2019-12904" } ] }, "last_update_date": "2024-11-23T22:25:58.024000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-480230", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf" }, { "title": "SSA-530931", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf" }, { "title": "Patches for multiple Siemens product denial of service vulnerabilities", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/160237" }, { "title": "Multiple Siemens Product security vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=91286" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-12904" }, { "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "db": "CNNVD", "id": "CNNVD-201904-458" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-125", "trust": 1.1 }, { "problemtype": "CWE-20", "trust": 0.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-158003" }, { "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "db": "NVD", "id": "CVE-2019-6568" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-099-06" }, { "trust": 2.0, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf" }, { "trust": 1.4, "url": "https://www.us-cert.gov/ics/advisories/icsa-19-227-04" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-6568" }, { "trust": 0.9, "url": "http://subscriber.communications.siemens.com/" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-6568" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2019.3150/" }, { "trust": 0.6, "url": "https://www.us-cert.gov/ics/advisories/icsa-19-099-06" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-19-099-06" }, { "trust": 0.6, "url": "https://www.securityfocus.com/bid/107842" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/siemens-simatic-denial-of-service-via-webserver-28976" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/78710" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-12904" }, { "db": "VULHUB", "id": "VHN-158003" }, { "db": "BID", "id": "107842" }, { "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "db": "CNNVD", "id": "CNNVD-201904-458" }, { "db": "NVD", "id": "CVE-2019-6568" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12" }, { "db": "CNVD", "id": "CNVD-2019-12904" }, { "db": "VULHUB", "id": "VHN-158003" }, { "db": "BID", "id": "107842" }, { "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "db": "CNNVD", "id": "CNNVD-201904-458" }, { "db": "NVD", "id": "CVE-2019-6568" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-05-05T00:00:00", "db": "IVD", "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12" }, { "date": "2019-05-05T00:00:00", "db": "CNVD", "id": "CNVD-2019-12904" }, { "date": "2019-04-17T00:00:00", "db": "VULHUB", "id": "VHN-158003" }, { "date": "2019-04-09T00:00:00", "db": "BID", "id": "107842" }, { "date": "2019-05-20T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "date": "2019-04-09T00:00:00", "db": "CNNVD", "id": "CNNVD-201904-458" }, { "date": "2019-04-17T14:29:03.683000", "db": "NVD", "id": "CVE-2019-6568" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-05-07T00:00:00", "db": "CNVD", "id": "CNVD-2019-12904" }, { "date": "2023-01-10T00:00:00", "db": "VULHUB", "id": "VHN-158003" }, { "date": "2019-04-09T00:00:00", "db": "BID", "id": "107842" }, { "date": "2019-08-20T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "date": "2023-04-12T00:00:00", "db": "CNNVD", "id": "CNNVD-201904-458" }, { "date": "2024-11-21T04:46:42.773000", "db": "NVD", "id": "CVE-2019-6568" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201904-458" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Vulnerability related to input validation in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-003541" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-201904-458" } ], "trust": 0.6 } }
var-201502-0370
Vulnerability from variot
The remote-management module in the (1) Multi Panels, (2) Comfort Panels, and (3) RT Advanced functionality in Siemens SIMATIC WinCC (TIA Portal) before 13 SP1 and in the (4) panels and (5) runtime functionality in SIMATIC WinCC flexible before 2008 SP3 Up7 does not properly encrypt credentials in transit, which makes it easier for remote attackers to determine cleartext credentials by sniffing the network and conducting a decryption attack. Siemens SIMATIC WinCC is a monitoring control and data acquisition SCADA and human machine interface HMI system. An information disclosure vulnerability exists in Siemens SIMATIC WinCC V13 SP1 that could allow an attacker to obtain sensitive information through man-in-the-middle attacks. Versions prior to Siemens SIMATIC WinCC TIA Portal V13 SP1 are vulnerable. The vulnerability stems from the fact that the program does not properly encrypt the certificate in transmission. A remote attacker could exploit this vulnerability by sniffing the network and performing a decryption attack to obtain clear text certificates
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201502-0370", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "wincc", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "13.0" }, { "model": "simatic wincc", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "13 sp1" }, { "model": "simatic wincc tia portal sp1", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v13" }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "wincc", "version": "13.0" }, { "model": "simatic wincc flexible runtime", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc flexible sp2", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc flexible sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2007" }, { "model": "simatic wincc flexible sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2005" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2005" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2004" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" } ], "sources": [ { "db": "IVD", "id": "6c5f6ee2-c09b-4c78-a362-83203bbfe346" }, { "db": "IVD", "id": "a11e037c-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2015-01296" }, { "db": "BID", "id": "72625" }, { "db": "JVNDB", "id": "JVNDB-2015-001537" }, { "db": "CNNVD", "id": "CNNVD-201502-420" }, { "db": "NVD", "id": "CVE-2015-1358" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2015-001537" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Gleb Gritsai, Roman Ilin, Aleksandr Tlyapov, and Sergey Gordeychik.", "sources": [ { "db": "BID", "id": "72625" } ], "trust": 0.3 }, "cve": "CVE-2015-1358", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2015-1358", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CNVD-2015-01296", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "6c5f6ee2-c09b-4c78-a362-83203bbfe346", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "a11e037c-2351-11e6-abef-000c29c66e3d", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "VHN-79319", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2015-1358", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2015-1358", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2015-01296", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201502-420", "trust": 0.6, "value": "MEDIUM" }, { "author": "IVD", "id": "6c5f6ee2-c09b-4c78-a362-83203bbfe346", "trust": 0.2, "value": "MEDIUM" }, { "author": "IVD", "id": "a11e037c-2351-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "MEDIUM" }, { "author": "VULHUB", "id": "VHN-79319", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "IVD", "id": "6c5f6ee2-c09b-4c78-a362-83203bbfe346" }, { "db": "IVD", "id": "a11e037c-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2015-01296" }, { "db": "VULHUB", "id": "VHN-79319" }, { "db": "JVNDB", "id": "JVNDB-2015-001537" }, { "db": "CNNVD", "id": "CNNVD-201502-420" }, { "db": "NVD", "id": "CVE-2015-1358" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "The remote-management module in the (1) Multi Panels, (2) Comfort Panels, and (3) RT Advanced functionality in Siemens SIMATIC WinCC (TIA Portal) before 13 SP1 and in the (4) panels and (5) runtime functionality in SIMATIC WinCC flexible before 2008 SP3 Up7 does not properly encrypt credentials in transit, which makes it easier for remote attackers to determine cleartext credentials by sniffing the network and conducting a decryption attack. Siemens SIMATIC WinCC is a monitoring control and data acquisition SCADA and human machine interface HMI system. An information disclosure vulnerability exists in Siemens SIMATIC WinCC V13 SP1 that could allow an attacker to obtain sensitive information through man-in-the-middle attacks. \nVersions prior to Siemens SIMATIC WinCC TIA Portal V13 SP1 are vulnerable. The vulnerability stems from the fact that the program does not properly encrypt the certificate in transmission. A remote attacker could exploit this vulnerability by sniffing the network and performing a decryption attack to obtain clear text certificates", "sources": [ { "db": "NVD", "id": "CVE-2015-1358" }, { "db": "JVNDB", "id": "JVNDB-2015-001537" }, { "db": "CNVD", "id": "CNVD-2015-01296" }, { "db": "BID", "id": "72625" }, { "db": "IVD", "id": "6c5f6ee2-c09b-4c78-a362-83203bbfe346" }, { "db": "IVD", "id": "a11e037c-2351-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-79319" } ], "trust": 2.88 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2015-1358", "trust": 3.9 }, { "db": "SIEMENS", "id": "SSA-543623", "trust": 2.3 }, { "db": "BID", "id": "72625", "trust": 2.0 }, { "db": "ICS CERT", "id": "ICSA-16-161-02", "trust": 1.9 }, { "db": "SIEMENS", "id": "SSA-526760", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-201502-420", "trust": 1.1 }, { "db": "SECTRACK", "id": "1036090", "trust": 1.1 }, { "db": "CNVD", "id": "CNVD-2015-01296", "trust": 1.0 }, { "db": "JVNDB", "id": "JVNDB-2015-001537", "trust": 0.8 }, { "db": "IVD", "id": "6C5F6EE2-C09B-4C78-A362-83203BBFE346", "trust": 0.2 }, { "db": "IVD", "id": "A11E037C-2351-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-79319", "trust": 0.1 }, { "db": "PACKETSTORM", "id": "130406", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "6c5f6ee2-c09b-4c78-a362-83203bbfe346" }, { "db": "IVD", "id": "a11e037c-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2015-01296" }, { "db": "VULHUB", "id": "VHN-79319" }, { "db": "BID", "id": "72625" }, { "db": "JVNDB", "id": "JVNDB-2015-001537" }, { "db": "PACKETSTORM", "id": "130406" }, { "db": "CNNVD", "id": "CNNVD-201502-420" }, { "db": "NVD", "id": "CVE-2015-1358" } ] }, "id": "VAR-201502-0370", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "6c5f6ee2-c09b-4c78-a362-83203bbfe346" }, { "db": "IVD", "id": "a11e037c-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2015-01296" }, { "db": "VULHUB", "id": "VHN-79319" } ], "trust": 1.7615187142857143 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 1.0 } ], "sources": [ { "db": "IVD", "id": "6c5f6ee2-c09b-4c78-a362-83203bbfe346" }, { "db": "IVD", "id": "a11e037c-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2015-01296" } ] }, "last_update_date": "2024-11-23T22:31:17.513000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-543623", "trust": 0.8, "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-543623.pdf" }, { "title": "Patch for Siemens SIMATIC WinCC TIA Portal Man-in-the-Middle Information Disclosure Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/55531" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2015-01296" }, { "db": "JVNDB", "id": "JVNDB-2015-001537" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-310", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-79319" }, { "db": "JVNDB", "id": "JVNDB-2015-001537" }, { "db": "NVD", "id": "CVE-2015-1358" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-543623.pdf" }, { "trust": 1.9, "url": "https://ics-cert.us-cert.gov/advisories/icsa-16-161-02" }, { "trust": 1.7, "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-526760.pdf" }, { "trust": 1.7, "url": "http://www.securityfocus.com/bid/72625" }, { "trust": 1.1, "url": "http://www.securitytracker.com/id/1036090" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2015-1358" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2015-1358" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2015-1358" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2014-4686" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2015-01296" }, { "db": "VULHUB", "id": "VHN-79319" }, { "db": "JVNDB", "id": "JVNDB-2015-001537" }, { "db": "PACKETSTORM", "id": "130406" }, { "db": "CNNVD", "id": "CNNVD-201502-420" }, { "db": "NVD", "id": "CVE-2015-1358" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "6c5f6ee2-c09b-4c78-a362-83203bbfe346" }, { "db": "IVD", "id": "a11e037c-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2015-01296" }, { "db": "VULHUB", "id": "VHN-79319" }, { "db": "BID", "id": "72625" }, { "db": "JVNDB", "id": "JVNDB-2015-001537" }, { "db": "PACKETSTORM", "id": "130406" }, { "db": "CNNVD", "id": "CNNVD-201502-420" }, { "db": "NVD", "id": "CVE-2015-1358" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2015-02-27T00:00:00", "db": "IVD", "id": "6c5f6ee2-c09b-4c78-a362-83203bbfe346" }, { "date": "2015-02-27T00:00:00", "db": "IVD", "id": "a11e037c-2351-11e6-abef-000c29c66e3d" }, { "date": "2015-02-26T00:00:00", "db": "CNVD", "id": "CNVD-2015-01296" }, { "date": "2015-02-18T00:00:00", "db": "VULHUB", "id": "VHN-79319" }, { "date": "2015-02-13T00:00:00", "db": "BID", "id": "72625" }, { "date": "2015-02-20T00:00:00", "db": "JVNDB", "id": "JVNDB-2015-001537" }, { "date": "2015-02-16T17:36:59", "db": "PACKETSTORM", "id": "130406" }, { "date": "2015-02-28T00:00:00", "db": "CNNVD", "id": "CNNVD-201502-420" }, { "date": "2015-02-18T02:59:07.813000", "db": "NVD", "id": "CVE-2015-1358" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2016-06-12T00:00:00", "db": "CNVD", "id": "CNVD-2015-01296" }, { "date": "2016-11-30T00:00:00", "db": "VULHUB", "id": "VHN-79319" }, { "date": "2016-07-06T14:57:00", "db": "BID", "id": "72625" }, { "date": "2016-06-10T00:00:00", "db": "JVNDB", "id": "JVNDB-2015-001537" }, { "date": "2015-02-28T00:00:00", "db": "CNNVD", "id": "CNNVD-201502-420" }, { "date": "2024-11-21T02:25:14.990000", "db": "NVD", "id": "CVE-2015-1358" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "PACKETSTORM", "id": "130406" }, { "db": "CNNVD", "id": "CNNVD-201502-420" } ], "trust": 0.7 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens SIMATIC WinCC TIA Portal Man-in-the-middle information disclosure vulnerability", "sources": [ { "db": "IVD", "id": "6c5f6ee2-c09b-4c78-a362-83203bbfe346" }, { "db": "IVD", "id": "a11e037c-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2015-01296" } ], "trust": 1.0 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "encryption problem", "sources": [ { "db": "CNNVD", "id": "CNNVD-201502-420" } ], "trust": 0.6 } }
var-201202-0047
Vulnerability from variot
CRLF injection vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via unspecified vectors. plural Siemens Product HMI Web The server CRLF An injection vulnerability exists.By any third party HTTP Inserted header, and HTTP Response splitting attacks can be triggered. Siemens SIMATIC is an automation software in a single engineering environment. The HMI web server has a header injection vulnerability that allows elevation of privilege, stealing data or breaking services. Siemens SIMATIC WinCC is prone to an HTTP-header-injection issue, a directory-traversal issue, and an arbitrary memory-read access issue because the application fails to properly sanitize user-supplied input. A remote attacker can exploit these issues to gain elevated privileges, obtain sensitive information, or cause denial-of-service conditions
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0047", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "mp" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "op" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "tp" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2007" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2005" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2004" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "comfort_panels" }, { "model": "wincc runtime advanced", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "v11" }, { "model": "wincc", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "v11" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "mobile_panels" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2004" }, { "model": "wincc flexible runtime", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2007" }, { "model": "wincc", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "v11" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2005" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "v11" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "comfort panels" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "mobile panels" }, { "model": "simatic wincc", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "v11 sp2 update 1" }, { "model": "simatic wincc flexible", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "2008 sp3" }, { "model": "simatic wincc flexible rumtime", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "v11" }, { "model": null, "scope": "eq", "trust": 0.6, "vendor": "wincc flexible", "version": "2008" }, { "model": "simatic wincc flexible runtime", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic hmi panels", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "wincc flexible runtime", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "wincc", "version": "v11" }, { "model": "simatic wincc flexible runtime", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2004" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2005" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2007" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc", "version": "*" }, { "model": "comfort panels", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "mobile panels", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "mp", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "op", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "tp", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc runtime advanced", "version": "v11" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible runtime", "version": "*" } ], "sources": [ { "db": "IVD", "id": "289d30d2-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0462" }, { "db": "BID", "id": "51836" }, { "db": "JVNDB", "id": "JVNDB-2012-001314" }, { "db": "CNNVD", "id": "CNNVD-201202-087" }, { "db": "NVD", "id": "CVE-2011-4512" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:siemens:simatic_hmi_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_flexible", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_flexible_runtime", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2012-001314" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "ICS-CERT", "sources": [ { "db": "BID", "id": "51836" }, { "db": "CNNVD", "id": "CNNVD-201202-087" } ], "trust": 0.9 }, "cve": "CVE-2011-4512", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2011-4512", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "289d30d2-2354-11e6-abef-000c29c66e3d", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-52457", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:P/A:N", "version": "2.0" } ], "cvssV3": [], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2011-4512", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2011-4512", "trust": 0.8, "value": "Medium" }, { "author": "CNNVD", "id": "CNNVD-201202-087", "trust": 0.6, "value": "MEDIUM" }, { "author": "IVD", "id": "289d30d2-2354-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "MEDIUM" }, { "author": "VULHUB", "id": "VHN-52457", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "IVD", "id": "289d30d2-2354-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-52457" }, { "db": "JVNDB", "id": "JVNDB-2012-001314" }, { "db": "CNNVD", "id": "CNNVD-201202-087" }, { "db": "NVD", "id": "CVE-2011-4512" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "CRLF injection vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via unspecified vectors. plural Siemens Product HMI Web The server CRLF An injection vulnerability exists.By any third party HTTP Inserted header, and HTTP Response splitting attacks can be triggered. Siemens SIMATIC is an automation software in a single engineering environment. The HMI web server has a header injection vulnerability that allows elevation of privilege, stealing data or breaking services. Siemens SIMATIC WinCC is prone to an HTTP-header-injection issue, a directory-traversal issue, and an arbitrary memory-read access issue because the application fails to properly sanitize user-supplied input. \nA remote attacker can exploit these issues to gain elevated privileges, obtain sensitive information, or cause denial-of-service conditions", "sources": [ { "db": "NVD", "id": "CVE-2011-4512" }, { "db": "JVNDB", "id": "JVNDB-2012-001314" }, { "db": "CNVD", "id": "CNVD-2012-0462" }, { "db": "BID", "id": "51836" }, { "db": "IVD", "id": "289d30d2-2354-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-52457" } ], "trust": 2.7 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2011-4512", "trust": 3.6 }, { "db": "ICS CERT", "id": "ICSA-12-030-01", "trust": 3.4 }, { "db": "SIEMENS", "id": "SSA-345442", "trust": 1.7 }, { "db": "CNVD", "id": "CNVD-2012-0462", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201202-087", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2012-001314", "trust": 0.8 }, { "db": "NSFOCUS", "id": "18633", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-12-030-01A", "trust": 0.3 }, { "db": "BID", "id": "51836", "trust": 0.3 }, { "db": "IVD", "id": "289D30D2-2354-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-52457", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "289d30d2-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0462" }, { "db": "VULHUB", "id": "VHN-52457" }, { "db": "BID", "id": "51836" }, { "db": "JVNDB", "id": "JVNDB-2012-001314" }, { "db": "CNNVD", "id": "CNNVD-201202-087" }, { "db": "NVD", "id": "CVE-2011-4512" } ] }, "id": "VAR-201202-0047", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "289d30d2-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0462" }, { "db": "VULHUB", "id": "VHN-52457" } ], "trust": 1.5153960400000002 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "289d30d2-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0462" } ] }, "last_update_date": "2024-11-23T21:46:29.458000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-345442", "trust": 0.8, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "title": "\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc", "trust": 0.8, "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx" }, { "title": "Top Page", "trust": 0.8, "url": "http://www.siemens.com/entry/jp/ja/" }, { "title": "Patch for Siemens SIMATIC WinCC HMI Header Injection Vulnerability (CNVD-2012-0462)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/9060" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2012-0462" }, { "db": "JVNDB", "id": "JVNDB-2012-001314" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-94", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-52457" }, { "db": "JVNDB", "id": "JVNDB-2012-001314" }, { "db": "NVD", "id": "CVE-2011-4512" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.4, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01.pdf" }, { "trust": 1.7, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4512" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4512" }, { "trust": 0.6, "url": "http://www.nsfocus.net/vulndb/18633" }, { "trust": 0.3, "url": "http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/scada/pages/default.aspx" }, { "trust": 0.3, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01a.pdf" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2012-0462" }, { "db": "VULHUB", "id": "VHN-52457" }, { "db": "BID", "id": "51836" }, { "db": "JVNDB", "id": "JVNDB-2012-001314" }, { "db": "CNNVD", "id": "CNNVD-201202-087" }, { "db": "NVD", "id": "CVE-2011-4512" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "289d30d2-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0462" }, { "db": "VULHUB", "id": "VHN-52457" }, { "db": "BID", "id": "51836" }, { "db": "JVNDB", "id": "JVNDB-2012-001314" }, { "db": "CNNVD", "id": "CNNVD-201202-087" }, { "db": "NVD", "id": "CVE-2011-4512" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2012-02-07T00:00:00", "db": "IVD", "id": "289d30d2-2354-11e6-abef-000c29c66e3d" }, { "date": "2012-02-07T00:00:00", "db": "CNVD", "id": "CNVD-2012-0462" }, { "date": "2012-02-03T00:00:00", "db": "VULHUB", "id": "VHN-52457" }, { "date": "2012-02-02T00:00:00", "db": "BID", "id": "51836" }, { "date": "2012-02-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001314" }, { "date": "2012-02-07T00:00:00", "db": "CNNVD", "id": "CNNVD-201202-087" }, { "date": "2012-02-03T20:55:01.453000", "db": "NVD", "id": "CVE-2011-4512" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2012-02-07T00:00:00", "db": "CNVD", "id": "CNVD-2012-0462" }, { "date": "2012-02-06T00:00:00", "db": "VULHUB", "id": "VHN-52457" }, { "date": "2012-04-18T21:20:00", "db": "BID", "id": "51836" }, { "date": "2012-02-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001314" }, { "date": "2012-02-07T00:00:00", "db": "CNNVD", "id": "CNNVD-201202-087" }, { "date": "2024-11-21T01:32:27.243000", "db": "NVD", "id": "CVE-2011-4512" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201202-087" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens SIMATIC WinCC HMI Web Server Multiple Input Validation Vulnerabilities", "sources": [ { "db": "BID", "id": "51836" }, { "db": "CNNVD", "id": "CNNVD-201202-087" } ], "trust": 0.9 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Code injection", "sources": [ { "db": "IVD", "id": "289d30d2-2354-11e6-abef-000c29c66e3d" }, { "db": "CNNVD", "id": "CNNVD-201202-087" } ], "trust": 0.8 } }
var-201202-0163
Vulnerability from variot
Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string. plural Siemens Product runtime loader HmiLoad Is Transfer A directory traversal vulnerability exists when the mode is enabled.By a third party .. ( Dot dot ) Arbitrary files may be executed, read, created, modified, or deleted via strings containing. Miniweb has a security vulnerability that allows an attacker to submit a specially crafted HTTP POST request to allow the server to access any illegal memory area while checking the extension of the requested file. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. HmiLoad provides functions that read data and unicode strings with stack-based buffer overflows, allowing an attacker to exploit a vulnerability to execute arbitrary code. HmiLoad has multiple security vulnerabilities that allow an attacker to stop a service or crash a service in multiple ways. A directory traversal vulnerability exists in the HmiLoad server that allows reading, writing, and deleting arbitrary files outside of the specified directory. Siemens SIMATIC is an automation software in a single engineering environment. A security vulnerability exists in the Siemens SIMATIC WinCC HMI web server. When the transfer mode is enabled, the runtime loader listens on the 2308/TCP or 50523/TCP port, but does not verify the submitted string, allowing the attacker to read and write any file in the file system. Attackers can exploit these issues to execute arbitrary code in the context of the affected application, read/write or delete arbitrary files outside of the server root directory, or cause denial-of-service conditions; other attacks may also be possible. (dots) in strings. ----------------------------------------------------------------------
Secunia is hiring!
Find your next job here:
http://secunia.com/company/jobs/
TITLE: Siemens SIMATIC WinCC Flexible HMI Miniweb Two Vulnerabilities
SECUNIA ADVISORY ID: SA46997
VERIFY ADVISORY: Secunia.com http://secunia.com/advisories/46997/ Customer Area (Credentials Required) https://ca.secunia.com/?page=viewadvisory&vuln_id=46997
RELEASE DATE: 2011-11-30
DISCUSS ADVISORY: http://secunia.com/advisories/46997/#comments
AVAILABLE ON SITE AND IN CUSTOMER AREA: * Last Update * Popularity * Comments * Criticality Level * Impact * Where * Solution Status * Operating System / Software * CVE Reference(s)
http://secunia.com/advisories/46997/
ONLY AVAILABLE IN CUSTOMER AREA: * Authentication Level * Report Reliability * Secunia PoC * Secunia Analysis * Systems Affected * Approve Distribution * Remediation Status * Secunia CVSS Score * CVSS
https://ca.secunia.com/?page=viewadvisory&vuln_id=46997
ONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI: * AUTOMATED SCANNING
http://secunia.com/vulnerability_scanning/personal/ http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/
DESCRIPTION: Luigi Auriemma has discovered two vulnerabilities in Siemens SIMATIC WinCC Flexible, which can be exploited by malicious people to disclose potentially sensitive information and cause a DoS (Denial of Service).
1) An input sanitisation error in Miniweb.exe when handling HTTP GET requests can be exploited to download arbitrary files via directory traversal attacks sent in a web request.
2) An input validation error in Miniweb.exe when handling HTTP POST requests can be exploited to crash the process via specially crafted content sent in a web request.
The vulnerabilities are confirmed in version 2008 SP2 Upd13 (K01.03.02.13_01.02.00.01). Other versions may also be affected.
SOLUTION: Restrict access to trusted hosts only.
PROVIDED AND/OR DISCOVERED BY: Luigi Auriemma
ORIGINAL ADVISORY: http://aluigi.altervista.org/adv/winccflex_1-adv.txt
OTHER REFERENCES: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
DEEP LINKS: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED DESCRIPTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED SOLUTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXPLOIT: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
About: This Advisory was delivered by Secunia as a free service to help private users keeping their systems up to date against the latest vulnerabilities.
Subscribe: http://secunia.com/advisories/secunia_security_advisories/
Definitions: (Criticality, Where etc.) http://secunia.com/advisories/about_secunia_advisories/
Please Note: Secunia recommends that you verify all advisories you receive by clicking the link. Secunia NEVER sends attached files with advisories. Secunia does not advise people to install third party patches, only use those supplied by the vendor.
Unsubscribe: Secunia Security Advisories http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org
Show details on source website
{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0163", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic wincc flexible runtime", "scope": null, "trust": 3.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc flexible sp2", "scope": "eq", "trust": 3.3, "vendor": "siemens", "version": "2008" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "mp" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "op" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "tp" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2007" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2005" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2004" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "2008" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "comfort_panels" }, { "model": "wincc runtime advanced", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "v11" }, { "model": "wincc", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "v11" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "mobile_panels" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "2007" }, { "model": "simatic wincc", "scope": "eq", "trust": 1.4, "vendor": "siemens", "version": "v11" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2004" }, { "model": "wincc flexible runtime", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2005" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "comfort panels" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "mobile panels" }, { "model": "simatic wincc flexible rumtime", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "v11" }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic hmi panels", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "wincc flexible runtime", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc flexible runtime", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc flexible sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc flexible sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2005" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2004" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2005" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2007" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2008" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc", "version": "v11" }, { "model": "comfort panels", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "mobile panels", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "mp", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "op", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "tp", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc runtime advanced", "version": "v11" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible runtime", "version": "*" } ], "sources": [ { "db": "IVD", "id": "28b71d12-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2011-5105" }, { "db": "CNVD", "id": "CNVD-2012-0466" }, { "db": "BID", "id": "50828" }, { "db": "JVNDB", "id": "JVNDB-2012-001318" }, { "db": "CNNVD", "id": "CNNVD-201202-091" }, { "db": "NVD", "id": "CVE-2011-4876" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:siemens:simatic_hmi_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_flexible", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_flexible_runtime", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2012-001318" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Luigi Auriemma", "sources": [ { "db": "BID", "id": "50828" }, { "db": "CNNVD", "id": "CNNVD-201111-480" } ], "trust": 0.9 }, "cve": "CVE-2011-4876", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.6, "id": "CVE-2011-4876", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.6, "id": "28b71d12-2354-11e6-abef-000c29c66e3d", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.6, "id": "VHN-52821", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:M/AU:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2011-4876", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2011-4876", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-201202-091", "trust": 0.6, "value": "CRITICAL" }, { "author": "IVD", "id": "28b71d12-2354-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "CRITICAL" }, { "author": "VULHUB", "id": "VHN-52821", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "IVD", "id": "28b71d12-2354-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-52821" }, { "db": "JVNDB", "id": "JVNDB-2012-001318" }, { "db": "CNNVD", "id": "CNNVD-201202-091" }, { "db": "NVD", "id": "CVE-2011-4876" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string. plural Siemens Product runtime loader HmiLoad Is Transfer A directory traversal vulnerability exists when the mode is enabled.By a third party .. ( Dot dot ) Arbitrary files may be executed, read, created, modified, or deleted via strings containing. Miniweb has a security vulnerability that allows an attacker to submit a specially crafted HTTP POST request to allow the server to access any illegal memory area while checking the extension of the requested file. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. HmiLoad provides functions that read data and unicode strings with stack-based buffer overflows, allowing an attacker to exploit a vulnerability to execute arbitrary code. HmiLoad has multiple security vulnerabilities that allow an attacker to stop a service or crash a service in multiple ways. A directory traversal vulnerability exists in the HmiLoad server that allows reading, writing, and deleting arbitrary files outside of the specified directory. Siemens SIMATIC is an automation software in a single engineering environment. A security vulnerability exists in the Siemens SIMATIC WinCC HMI web server. When the transfer mode is enabled, the runtime loader listens on the 2308/TCP or 50523/TCP port, but does not verify the submitted string, allowing the attacker to read and write any file in the file system. \nAttackers can exploit these issues to execute arbitrary code in the context of the affected application, read/write or delete arbitrary files outside of the server root directory, or cause denial-of-service conditions; other attacks may also be possible. (dots) in strings. ----------------------------------------------------------------------\n\nSecunia is hiring!\n\nFind your next job here:\n\nhttp://secunia.com/company/jobs/\n\n----------------------------------------------------------------------\n\nTITLE:\nSiemens SIMATIC WinCC Flexible HMI Miniweb Two Vulnerabilities\n\nSECUNIA ADVISORY ID:\nSA46997\n\nVERIFY ADVISORY:\nSecunia.com\nhttp://secunia.com/advisories/46997/\nCustomer Area (Credentials Required)\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=46997\n\nRELEASE DATE:\n2011-11-30\n\nDISCUSS ADVISORY:\nhttp://secunia.com/advisories/46997/#comments\n\nAVAILABLE ON SITE AND IN CUSTOMER AREA:\n * Last Update\n * Popularity\n * Comments\n * Criticality Level\n * Impact\n * Where\n * Solution Status\n * Operating System / Software\n * CVE Reference(s)\n\nhttp://secunia.com/advisories/46997/\n\nONLY AVAILABLE IN CUSTOMER AREA:\n * Authentication Level\n * Report Reliability\n * Secunia PoC\n * Secunia Analysis\n * Systems Affected\n * Approve Distribution\n * Remediation Status\n * Secunia CVSS Score\n * CVSS\n\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=46997\n\nONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI:\n * AUTOMATED SCANNING\n\nhttp://secunia.com/vulnerability_scanning/personal/\nhttp://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/\n\nDESCRIPTION:\nLuigi Auriemma has discovered two vulnerabilities in Siemens SIMATIC\nWinCC Flexible, which can be exploited by malicious people to\ndisclose potentially sensitive information and cause a DoS (Denial of\nService). \n\n1) An input sanitisation error in Miniweb.exe when handling HTTP GET\nrequests can be exploited to download arbitrary files via directory\ntraversal attacks sent in a web request. \n\n2) An input validation error in Miniweb.exe when handling HTTP POST\nrequests can be exploited to crash the process via specially crafted\ncontent sent in a web request. \n\nThe vulnerabilities are confirmed in version 2008 SP2 Upd13\n(K01.03.02.13_01.02.00.01). Other versions may also be affected. \n\nSOLUTION:\nRestrict access to trusted hosts only. \n\nPROVIDED AND/OR DISCOVERED BY:\nLuigi Auriemma\n\nORIGINAL ADVISORY:\nhttp://aluigi.altervista.org/adv/winccflex_1-adv.txt\n\nOTHER REFERENCES:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nDEEP LINKS:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED DESCRIPTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED SOLUTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXPLOIT:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\n----------------------------------------------------------------------\n\nAbout:\nThis Advisory was delivered by Secunia as a free service to help\nprivate users keeping their systems up to date against the latest\nvulnerabilities. \n\nSubscribe:\nhttp://secunia.com/advisories/secunia_security_advisories/\n\nDefinitions: (Criticality, Where etc.)\nhttp://secunia.com/advisories/about_secunia_advisories/\n\n\nPlease Note:\nSecunia recommends that you verify all advisories you receive by\nclicking the link. \nSecunia NEVER sends attached files with advisories. \nSecunia does not advise people to install third party patches, only\nuse those supplied by the vendor. \n\n----------------------------------------------------------------------\n\nUnsubscribe: Secunia Security Advisories\nhttp://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org\n\n----------------------------------------------------------------------\n\n\n", "sources": [ { "db": "NVD", "id": "CVE-2011-4876" }, { "db": "JVNDB", "id": "JVNDB-2012-001318" }, { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2011-5105" }, { "db": "CNVD", "id": "CNVD-2012-0466" }, { "db": "BID", "id": "50828" }, { "db": "IVD", "id": "28b71d12-2354-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-52821" }, { "db": "PACKETSTORM", "id": "107419" } ], "trust": 5.49 }, "exploit_availability": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/exploit_availability#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "reference": "https://www.scap.org.cn/vuln/vhn-52821", "trust": 0.1, "type": "unknown" } ], "sources": [ { "db": "VULHUB", "id": "VHN-52821" } ] }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "BID", "id": "50828", "trust": 3.9 }, { "db": "NVD", "id": "CVE-2011-4876", "trust": 3.6 }, { "db": "ICS CERT", "id": "ICSA-12-030-01", "trust": 3.4 }, { "db": "SIEMENS", "id": "SSA-345442", "trust": 1.7 }, { "db": "SECUNIA", "id": "46997", "trust": 1.2 }, { "db": "ICS CERT ALERT", "id": "ICS-ALERT-11-332-02A", "trust": 1.1 }, { "db": "ICS CERT ALERT", "id": "ICS-ALERT-11-332-02", "trust": 1.1 }, { "db": "OSVDB", "id": "77381", "trust": 1.1 }, { "db": "EXPLOIT-DB", "id": "18166", "trust": 1.1 }, { "db": "CNNVD", "id": "CNNVD-201202-091", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2012-0466", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2012-001318", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2011-5108", "trust": 0.6 }, { "db": "CNVD", "id": "CNVD-2011-5110", "trust": 0.6 }, { "db": "CNVD", "id": "CNVD-2011-5103", "trust": 0.6 }, { "db": "CNVD", "id": "CNVD-2011-5107", "trust": 0.6 }, { "db": "CNVD", "id": "CNVD-2011-5105", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-201111-480", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-12-030-01A", "trust": 0.3 }, { "db": "IVD", "id": "28B71D12-2354-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-52821", "trust": 0.1 }, { "db": "PACKETSTORM", "id": "107419", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "28b71d12-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2011-5105" }, { "db": "CNVD", "id": "CNVD-2012-0466" }, { "db": "VULHUB", "id": "VHN-52821" }, { "db": "BID", "id": "50828" }, { "db": "JVNDB", "id": "JVNDB-2012-001318" }, { "db": "PACKETSTORM", "id": "107419" }, { "db": "CNNVD", "id": "CNNVD-201111-480" }, { "db": "CNNVD", "id": "CNNVD-201202-091" }, { "db": "NVD", "id": "CVE-2011-4876" } ] }, "id": "VAR-201202-0163", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "28b71d12-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2011-5105" }, { "db": "CNVD", "id": "CNVD-2012-0466" }, { "db": "VULHUB", "id": "VHN-52821" } ], "trust": 4.568457485714285 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 3.8 } ], "sources": [ { "db": "IVD", "id": "28b71d12-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2011-5105" }, { "db": "CNVD", "id": "CNVD-2012-0466" } ] }, "last_update_date": "2024-11-23T21:46:29.307000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-345442", "trust": 0.8, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "title": "\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc", "trust": 0.8, "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx" }, { "title": "Top Page", "trust": 0.8, "url": "http://www.siemens.com/entry/jp/ja/" }, { "title": "Patch for Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 file download vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/72694" }, { "title": "Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 memory access vulnerability patch", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/72697" }, { "title": "Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 Buffer Overflow Vulnerability Patch", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/72705" }, { "title": "Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 service crash vulnerability patch", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/72689" }, { "title": "Patch for Siemens SIMATIC WinCC HMI Directory Traversal Vulnerability (CNVD-2012-0466)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/9072" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2012-0466" }, { "db": "JVNDB", "id": "JVNDB-2012-001318" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-22", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-52821" }, { "db": "JVNDB", "id": "JVNDB-2012-001318" }, { "db": "NVD", "id": "CVE-2011-4876" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 4.0, "url": "http://aluigi.altervista.org/adv/winccflex_1-adv.txt" }, { "trust": 3.4, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01.pdf" }, { "trust": 1.7, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "trust": 1.1, "url": "http://www.exploit-db.com/exploits/18166" }, { "trust": 1.1, "url": "http://aluigi.org/adv/winccflex_1-adv.txt" }, { "trust": 1.1, "url": "http://www.us-cert.gov/control_systems/pdf/ics-alert-11-332-02.pdf" }, { "trust": 1.1, "url": "http://www.us-cert.gov/control_systems/pdf/ics-alert-11-332-02a.pdf" }, { "trust": 1.1, "url": "http://www.osvdb.org/77381" }, { "trust": 1.1, "url": "http://secunia.com/advisories/46997" }, { "trust": 1.1, "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71450" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4876" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4876" }, { "trust": 0.6, "url": "http://www.securityfocus.com/bid/50828" }, { "trust": 0.3, "url": "http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/wincc-flexible/wincc-flexible-runtime/pages/default.aspx" }, { "trust": 0.3, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01a.pdf" }, { "trust": 0.1, "url": "http://secunia.com/company/jobs/" }, { "trust": 0.1, "url": "http://secunia.com/vulnerability_intelligence/" }, { "trust": 0.1, "url": "http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/" }, { "trust": 0.1, "url": "http://secunia.com/advisories/secunia_security_advisories/" }, { "trust": 0.1, "url": "http://secunia.com/vulnerability_scanning/personal/" }, { "trust": 0.1, "url": "http://secunia.com/advisories/46997/" }, { "trust": 0.1, "url": "http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org" }, { "trust": 0.1, "url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=46997" }, { "trust": 0.1, "url": "http://secunia.com/advisories/46997/#comments" }, { "trust": 0.1, "url": "http://secunia.com/advisories/about_secunia_advisories/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2011-5105" }, { "db": "CNVD", "id": "CNVD-2012-0466" }, { "db": "VULHUB", "id": "VHN-52821" }, { "db": "BID", "id": "50828" }, { "db": "JVNDB", "id": "JVNDB-2012-001318" }, { "db": "PACKETSTORM", "id": "107419" }, { "db": "CNNVD", "id": "CNNVD-201111-480" }, { "db": "CNNVD", "id": "CNNVD-201202-091" }, { "db": "NVD", "id": "CVE-2011-4876" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "28b71d12-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2011-5105" }, { "db": "CNVD", "id": "CNVD-2012-0466" }, { "db": "VULHUB", "id": "VHN-52821" }, { "db": "BID", "id": "50828" }, { "db": "JVNDB", "id": "JVNDB-2012-001318" }, { "db": "PACKETSTORM", "id": "107419" }, { "db": "CNNVD", "id": "CNNVD-201111-480" }, { "db": "CNNVD", "id": "CNNVD-201202-091" }, { "db": "NVD", "id": "CVE-2011-4876" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2012-02-07T00:00:00", "db": "IVD", "id": "28b71d12-2354-11e6-abef-000c29c66e3d" }, { "date": "2011-12-05T00:00:00", "db": "CNVD", "id": "CNVD-2011-5108" }, { "date": "2011-12-05T00:00:00", "db": "CNVD", "id": "CNVD-2011-5110" }, { "date": "2011-12-05T00:00:00", "db": "CNVD", "id": "CNVD-2011-5103" }, { "date": "2011-12-05T00:00:00", "db": "CNVD", "id": "CNVD-2011-5107" }, { "date": "2011-12-05T00:00:00", "db": "CNVD", "id": "CNVD-2011-5105" }, { "date": "2012-02-07T00:00:00", "db": "CNVD", "id": "CNVD-2012-0466" }, { "date": "2012-02-03T00:00:00", "db": "VULHUB", "id": "VHN-52821" }, { "date": "2011-11-28T00:00:00", "db": "BID", "id": "50828" }, { "date": "2012-02-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001318" }, { "date": "2011-11-30T03:40:12", "db": "PACKETSTORM", "id": "107419" }, { "date": "1900-01-01T00:00:00", "db": "CNNVD", "id": "CNNVD-201111-480" }, { "date": "2012-02-07T00:00:00", "db": "CNNVD", "id": "CNNVD-201202-091" }, { "date": "2012-02-03T20:55:01.937000", "db": "NVD", "id": "CVE-2011-4876" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2016-03-15T00:00:00", "db": "CNVD", "id": "CNVD-2011-5108" }, { "date": "2016-03-15T00:00:00", "db": "CNVD", "id": "CNVD-2011-5110" }, { "date": "2016-03-15T00:00:00", "db": "CNVD", "id": "CNVD-2011-5103" }, { "date": "2016-03-15T00:00:00", "db": "CNVD", "id": "CNVD-2011-5107" }, { "date": "2011-12-05T00:00:00", "db": "CNVD", "id": "CNVD-2011-5105" }, { "date": "2012-02-07T00:00:00", "db": "CNVD", "id": "CNVD-2012-0466" }, { "date": "2017-08-29T00:00:00", "db": "VULHUB", "id": "VHN-52821" }, { "date": "2012-04-18T21:20:00", "db": "BID", "id": "50828" }, { "date": "2012-02-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001318" }, { "date": "2011-11-30T00:00:00", "db": "CNNVD", "id": "CNNVD-201111-480" }, { "date": "2012-02-07T00:00:00", "db": "CNNVD", "id": "CNNVD-201202-091" }, { "date": "2024-11-21T01:33:10.577000", "db": "NVD", "id": "CVE-2011-4876" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201111-480" }, { "db": "CNNVD", "id": "CNNVD-201202-091" } ], "trust": 1.2 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Siemens Product HmiLoad Vulnerable to directory traversal", "sources": [ { "db": "JVNDB", "id": "JVNDB-2012-001318" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Path traversal", "sources": [ { "db": "IVD", "id": "28b71d12-2354-11e6-abef-000c29c66e3d" }, { "db": "CNNVD", "id": "CNNVD-201202-091" } ], "trust": 0.8 } }
var-201407-0606
Vulnerability from variot
The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during the sniffing of network traffic on TCP port 1030. Supplementary information : CWE Vulnerability type by CWE-798: Use of Hard-coded Credentials ( Using hard-coded credentials ) Has been identified. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. A privilege elevation vulnerability exists in Siemens SIMATIC WinCC and PCS7 that allows an attacker to exploit the vulnerability to gain administrative access on the affected device. Siemens SIMATIC WinCC and PCS7 are prone to a privilege-escalation vulnerability. Siemens SIMATIC WinCC is a set of automatic data acquisition and monitoring (SCADA) system of German Siemens (Siemens). The system provides process monitoring, data acquisition and other functions
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201407-0606", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": null, "scope": "eq", "trust": 2.4, "vendor": "wincc", "version": "6.0" }, { "model": null, "scope": "eq", "trust": 2.4, "vendor": "wincc", "version": "7.0" }, { "model": "wincc", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "6.0" }, { "model": "wincc", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "5.0" }, { "model": "wincc", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "7.0" }, { "model": "simatic wincc", "scope": "lt", "trust": 1.4, "vendor": "siemens", "version": "7.3" }, { "model": null, "scope": "eq", "trust": 1.2, "vendor": "wincc", "version": "5.0" }, { "model": null, "scope": "eq", "trust": 1.2, "vendor": "wincc", "version": "7.1" }, { "model": "wincc", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "7.2" }, { "model": "simatic pcs7", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "7.1" }, { "model": "simatic pcs7", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "8.0" }, { "model": "simatic pcs7", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "8.0" }, { "model": "wincc", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "7.1" }, { "model": "simatic pcs 7", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "8.1" }, { "model": null, "scope": "eq", "trust": 0.6, "vendor": "simatic pcs7", "version": "7.1" }, { "model": null, "scope": "eq", "trust": 0.6, "vendor": "simatic pcs7", "version": "8.0" }, { "model": null, "scope": "eq", "trust": 0.6, "vendor": "simatic pcs7", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.6, "vendor": "wincc", "version": "*" }, { "model": "pcs7", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "8.1" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "6.2" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" } ], "sources": [ { "db": "IVD", "id": "ea209009-7fdb-4811-b130-403cdc16f255" }, { "db": "IVD", "id": "7d720861-463f-11e9-a37c-000c29342cb1" }, { "db": "IVD", "id": "e2ce69a6-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2014-04643" }, { "db": "BID", "id": "68875" }, { "db": "JVNDB", "id": "JVNDB-2014-003569" }, { "db": "CNNVD", "id": "CNNVD-201407-606" }, { "db": "NVD", "id": "CVE-2014-4686" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:siemens:simatic_pcs_7", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2014-003569" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Sergey Gordeychik, Alexander Tlyapov, Dmitry Nagibin, and Gleb Gritsai from Positive Technologies.", "sources": [ { "db": "BID", "id": "68875" } ], "trust": 0.3 }, "cve": "CVE-2014-4686", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "CVE-2014-4686", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "CNVD-2014-04643", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "ea209009-7fdb-4811-b130-403cdc16f255", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.2, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.9 [IVD]" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "7d720861-463f-11e9-a37c-000c29342cb1", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.2, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.9 [IVD]" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "e2ce69a6-2351-11e6-abef-000c29c66e3d", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.2, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.9 [IVD]" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "VHN-72627", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2014-4686", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2014-4686", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2014-04643", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201407-606", "trust": 0.6, "value": "MEDIUM" }, { "author": "IVD", "id": "ea209009-7fdb-4811-b130-403cdc16f255", "trust": 0.2, "value": "MEDIUM" }, { "author": "IVD", "id": "7d720861-463f-11e9-a37c-000c29342cb1", "trust": 0.2, "value": "MEDIUM" }, { "author": "IVD", "id": "e2ce69a6-2351-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "MEDIUM" }, { "author": "VULHUB", "id": "VHN-72627", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "IVD", "id": "ea209009-7fdb-4811-b130-403cdc16f255" }, { "db": "IVD", "id": "7d720861-463f-11e9-a37c-000c29342cb1" }, { "db": "IVD", "id": "e2ce69a6-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2014-04643" }, { "db": "VULHUB", "id": "VHN-72627" }, { "db": "JVNDB", "id": "JVNDB-2014-003569" }, { "db": "CNNVD", "id": "CNNVD-201407-606" }, { "db": "NVD", "id": "CVE-2014-4686" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during the sniffing of network traffic on TCP port 1030. Supplementary information : CWE Vulnerability type by CWE-798: Use of Hard-coded Credentials ( Using hard-coded credentials ) Has been identified. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. A privilege elevation vulnerability exists in Siemens SIMATIC WinCC and PCS7 that allows an attacker to exploit the vulnerability to gain administrative access on the affected device. Siemens SIMATIC WinCC and PCS7 are prone to a privilege-escalation vulnerability. Siemens SIMATIC WinCC is a set of automatic data acquisition and monitoring (SCADA) system of German Siemens (Siemens). The system provides process monitoring, data acquisition and other functions", "sources": [ { "db": "NVD", "id": "CVE-2014-4686" }, { "db": "JVNDB", "id": "JVNDB-2014-003569" }, { "db": "CNVD", "id": "CNVD-2014-04643" }, { "db": "BID", "id": "68875" }, { "db": "IVD", "id": "ea209009-7fdb-4811-b130-403cdc16f255" }, { "db": "IVD", "id": "7d720861-463f-11e9-a37c-000c29342cb1" }, { "db": "IVD", "id": "e2ce69a6-2351-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-72627" } ], "trust": 3.06 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2014-4686", "trust": 4.2 }, { "db": "SIEMENS", "id": "SSA-214365", "trust": 2.3 }, { "db": "CNNVD", "id": "CNNVD-201407-606", "trust": 1.3 }, { "db": "CNVD", "id": "CNVD-2014-04643", "trust": 1.2 }, { "db": "BID", "id": "68875", "trust": 1.0 }, { "db": "ICS CERT", "id": "ICSA-14-205-02", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2014-003569", "trust": 0.8 }, { "db": "SECUNIA", "id": "60392", "trust": 0.6 }, { "db": "SECUNIA", "id": "60388", "trust": 0.6 }, { "db": "IVD", "id": "EA209009-7FDB-4811-B130-403CDC16F255", "trust": 0.2 }, { "db": "IVD", "id": "7D720861-463F-11E9-A37C-000C29342CB1", "trust": 0.2 }, { "db": "IVD", "id": "E2CE69A6-2351-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "PACKETSTORM", "id": "130406", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-72627", "trust": 0.1 }, { "db": "PACKETSTORM", "id": "127660", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "ea209009-7fdb-4811-b130-403cdc16f255" }, { "db": "IVD", "id": "7d720861-463f-11e9-a37c-000c29342cb1" }, { "db": "IVD", "id": "e2ce69a6-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2014-04643" }, { "db": "VULHUB", "id": "VHN-72627" }, { "db": "BID", "id": "68875" }, { "db": "JVNDB", "id": "JVNDB-2014-003569" }, { "db": "PACKETSTORM", "id": "130406" }, { "db": "PACKETSTORM", "id": "127660" }, { "db": "CNNVD", "id": "CNNVD-201407-606" }, { "db": "NVD", "id": "CVE-2014-4686" } ] }, "id": "VAR-201407-0606", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "ea209009-7fdb-4811-b130-403cdc16f255" }, { "db": "IVD", "id": "7d720861-463f-11e9-a37c-000c29342cb1" }, { "db": "IVD", "id": "e2ce69a6-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2014-04643" }, { "db": "VULHUB", "id": "VHN-72627" } ], "trust": 1.9749411600000002 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 1.2 } ], "sources": [ { "db": "IVD", "id": "ea209009-7fdb-4811-b130-403cdc16f255" }, { "db": "IVD", "id": "7d720861-463f-11e9-a37c-000c29342cb1" }, { "db": "IVD", "id": "e2ce69a6-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2014-04643" } ] }, "last_update_date": "2024-11-23T22:31:17.616000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-214365", "trust": 0.8, "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-214365.pdf" }, { "title": "Patch for Siemens SIMATIC WinCC and PCS7 Privilege Escalation Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/47905" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2014-04643" }, { "db": "JVNDB", "id": "JVNDB-2014-003569" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-Other", "trust": 1.0 }, { "problemtype": "CWE-Other", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2014-003569" }, { "db": "NVD", "id": "CVE-2014-4686" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-214365.pdf" }, { "trust": 1.4, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2014-4686" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-4686" }, { "trust": 0.8, "url": "https://ics-cert.us-cert.gov/advisories/icsa-14-205-02" }, { "trust": 0.6, "url": "http://www.securityfocus.com/bid/68875" }, { "trust": 0.6, "url": "http://secunia.com/advisories/60388" }, { "trust": 0.6, "url": "http://secunia.com/advisories/60392" }, { "trust": 0.3, "url": "http://subscriber.communications.siemens.com/" }, { "trust": 0.2, "url": "https://nvd.nist.gov/vuln/detail/cve-2014-4686" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2015-1358" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2014-4684" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2014-4683" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2014-4685" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2014-4682" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2014-04643" }, { "db": "VULHUB", "id": "VHN-72627" }, { "db": "BID", "id": "68875" }, { "db": "JVNDB", "id": "JVNDB-2014-003569" }, { "db": "PACKETSTORM", "id": "130406" }, { "db": "PACKETSTORM", "id": "127660" }, { "db": "CNNVD", "id": "CNNVD-201407-606" }, { "db": "NVD", "id": "CVE-2014-4686" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "ea209009-7fdb-4811-b130-403cdc16f255" }, { "db": "IVD", "id": "7d720861-463f-11e9-a37c-000c29342cb1" }, { "db": "IVD", "id": "e2ce69a6-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2014-04643" }, { "db": "VULHUB", "id": "VHN-72627" }, { "db": "BID", "id": "68875" }, { "db": "JVNDB", "id": "JVNDB-2014-003569" }, { "db": "PACKETSTORM", "id": "130406" }, { "db": "PACKETSTORM", "id": "127660" }, { "db": "CNNVD", "id": "CNNVD-201407-606" }, { "db": "NVD", "id": "CVE-2014-4686" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2014-07-28T00:00:00", "db": "IVD", "id": "ea209009-7fdb-4811-b130-403cdc16f255" }, { "date": "2014-07-28T00:00:00", "db": "IVD", "id": "7d720861-463f-11e9-a37c-000c29342cb1" }, { "date": "2014-07-28T00:00:00", "db": "IVD", "id": "e2ce69a6-2351-11e6-abef-000c29c66e3d" }, { "date": "2014-07-28T00:00:00", "db": "CNVD", "id": "CNVD-2014-04643" }, { "date": "2014-07-24T00:00:00", "db": "VULHUB", "id": "VHN-72627" }, { "date": "2014-07-23T00:00:00", "db": "BID", "id": "68875" }, { "date": "2014-07-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2014-003569" }, { "date": "2015-02-16T17:36:59", "db": "PACKETSTORM", "id": "130406" }, { "date": "2014-07-29T22:37:22", "db": "PACKETSTORM", "id": "127660" }, { "date": "2014-07-25T00:00:00", "db": "CNNVD", "id": "CNNVD-201407-606" }, { "date": "2014-07-24T14:55:08.190000", "db": "NVD", "id": "CVE-2014-4686" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2014-07-28T00:00:00", "db": "CNVD", "id": "CNVD-2014-04643" }, { "date": "2014-07-25T00:00:00", "db": "VULHUB", "id": "VHN-72627" }, { "date": "2015-03-19T09:08:00", "db": "BID", "id": "68875" }, { "date": "2014-08-05T00:00:00", "db": "JVNDB", "id": "JVNDB-2014-003569" }, { "date": "2014-07-25T00:00:00", "db": "CNNVD", "id": "CNNVD-201407-606" }, { "date": "2024-11-21T02:10:42.220000", "db": "NVD", "id": "CVE-2014-4686" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "PACKETSTORM", "id": "130406" }, { "db": "CNNVD", "id": "CNNVD-201407-606" } ], "trust": 0.7 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens SIMATIC PCS 7 Used in products such as SIMATIC WinCC Vulnerabilities in which important information is obtained in project management applications", "sources": [ { "db": "JVNDB", "id": "JVNDB-2014-003569" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Encryption issues", "sources": [ { "db": "IVD", "id": "ea209009-7fdb-4811-b130-403cdc16f255" }, { "db": "IVD", "id": "7d720861-463f-11e9-a37c-000c29342cb1" }, { "db": "IVD", "id": "e2ce69a6-2351-11e6-abef-000c29c66e3d" } ], "trust": 0.6 } }
var-202103-1464
Vulnerability from variot
An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j). The product supports a variety of encryption algorithms, including symmetric ciphers, hash algorithms, secure hash algorithms, etc. Summary:
Openshift Serverless 1.10.2 is now available. This version of the OpenShift Serverless Operator is supported on Red Hat OpenShift Container Platform version 4.5. Solution:
See the documentation at: https://access.redhat.com/documentation/en-us/openshift_container_platform/ 4.5/html/serverless_applications/index
Bug Fix(es):
-
WMCO patch pub-key-hash annotation to Linux node (BZ#1945248)
-
LoadBalancer Service type with invalid external loadbalancer IP breaks the datapath (BZ#1952917)
-
Telemetry info not completely available to identify windows nodes (BZ#1955319)
-
WMCO incorrectly shows node as ready after a failed configuration (BZ#1956412)
-
kube-proxy service terminated unexpectedly after recreated LB service (BZ#1963263)
-
Solution:
For Windows Machine Config Operator upgrades, see the following documentation:
https://docs.openshift.com/container-platform/4.7/windows_containers/window s-node-upgrades.html
- Bugs fixed (https://bugzilla.redhat.com/):
1945248 - WMCO patch pub-key-hash annotation to Linux node 1946538 - CVE-2021-25736 kubernetes: LoadBalancer Service type don't create a HNS policy for empty or invalid external loadbalancer IP, what could lead to MITM 1952917 - LoadBalancer Service type with invalid external loadbalancer IP breaks the datapath 1955319 - Telemetry info not completely available to identify windows nodes 1956412 - WMCO incorrectly shows node as ready after a failed configuration 1963263 - kube-proxy service terminated unexpectedly after recreated LB service
- Description:
Red Hat Advanced Cluster Management for Kubernetes 2.0.10 images
Red Hat Advanced Cluster Management for Kubernetes provides the capabilities to address common challenges that administrators and site reliability engineers face as they work across a range of public and private cloud environments. Clusters and applications are all visible and managed from a single console—with security policy built in.
Bug fix:
-
RHACM 2.0.10 images (BZ #1940452)
-
Bugs fixed (https://bugzilla.redhat.com/):
1940452 - RHACM 2.0.10 images 1944286 - CVE-2021-23358 nodejs-underscore: Arbitrary code execution via the template function
- ========================================================================== Ubuntu Security Notice USN-4891-1 March 25, 2021
openssl vulnerability
A security issue affects these releases of Ubuntu and its derivatives:
- Ubuntu 20.10
- Ubuntu 20.04 LTS
- Ubuntu 18.04 LTS
Summary:
OpenSSL could be made to crash or run programs if it received specially crafted network traffic. A remote attacker could use this issue to cause OpenSSL to crash, resulting in a denial of service, or possibly execute arbitrary code.
Update instructions:
The problem can be corrected by updating your system to the following package versions:
Ubuntu 20.10: libssl1.1 1.1.1f-1ubuntu4.3
Ubuntu 20.04 LTS: libssl1.1 1.1.1f-1ubuntu2.3
Ubuntu 18.04 LTS: libssl1.1 1.1.1-1ubuntu2.1~18.04.9
After a standard system update you need to reboot your computer to make all the necessary changes. 8) - aarch64, ppc64le, s390x, x86_64
- Description:
OpenSSL is a toolkit that implements the Secure Sockets Layer (SSL) and Transport Layer Security (TLS) protocols, as well as a full-strength general-purpose cryptography library. Solution:
For details on how to apply this update, which includes the changes described in this advisory, refer to:
https://access.redhat.com/articles/11258
For the update to take effect, all services linked to the OpenSSL library must be restarted, or the system rebooted. Package List:
Red Hat Enterprise Linux BaseOS (v. Our key and details on how to verify the signature are available from https://access.redhat.com/security/team/key/
- -----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256
====================================================================
Red Hat Security Advisory
Synopsis: Important: Red Hat JBoss Core Services Apache HTTP Server 2.4.37 SP7 security update Advisory ID: RHSA-2021:1200-01 Product: Red Hat JBoss Core Services Advisory URL: https://access.redhat.com/errata/RHSA-2021:1200 Issue date: 2021-04-14 CVE Names: CVE-2021-3449 CVE-2021-3450 ==================================================================== 1. Summary:
Red Hat JBoss Core Services Pack Apache Server 2.4.37 Service Pack 7 zip release for RHEL 7, RHEL 8 and Microsoft Windows is available.
Red Hat Product Security has rated this update as having a security impact of Important. A Common Vulnerability Scoring System (CVSS) base score, which gives a detailed severity rating, is available for each vulnerability from the CVE link(s) in the References section.
- Description:
Red Hat JBoss Core Services is a set of supplementary software for Red Hat JBoss middleware products. This software, such as Apache HTTP Server, is common to multiple JBoss middleware products, and is packaged under Red Hat JBoss Core Services to allow for faster distribution of updates, and for a more consistent update experience.
This release adds the new Apache HTTP Server 2.4.37 Service Pack 7 packages that are part of the JBoss Core Services offering.
This release serves as a replacement for Red Hat JBoss Core Services Pack Apache Server 2.4.37 Service Pack 6 and includes bug fixes and enhancements. Refer to the Release Notes for information on the most significant bug fixes and enhancements included in this release.
Security fix(es):
-
openssl: NULL pointer deref in signature_algorithms processing (CVE-2021-3449)
-
openssl: CA certificate check bypass with X509_V_FLAG_X509_STRICT (CVE-2021-3450)
For more details about the security issue(s), including the impact, a CVSS score, acknowledgments, and other related information, refer to the CVE page(s) listed in the References section.
- Solution:
Before applying the update, back up your existing installation, including all applications, configuration files, databases and database settings, and so on.
The References section of this erratum contains a download link for the update. You must be logged in to download the update.
- Bugs fixed (https://bugzilla.redhat.com/):
1941547 - CVE-2021-3450 openssl: CA certificate check bypass with X509_V_FLAG_X509_STRICT 1941554 - CVE-2021-3449 openssl: NULL pointer dereference in signature_algorithms processing
- References:
https://access.redhat.com/security/cve/CVE-2021-3449 https://access.redhat.com/security/cve/CVE-2021-3450 https://access.redhat.com/security/updates/classification/#important https://access.redhat.com/jbossnetwork/restricted/listSoftware.html?product=core.service.apachehttp&downloadType=securityPatches&version=2.4.37
- Contact:
The Red Hat security contact is secalert@redhat.com. More contact details at https://access.redhat.com/security/team/contact/
Copyright 2021 Red Hat, Inc. -----BEGIN PGP SIGNATURE----- Version: GnuPG v1
iQIVAwUBYHcRztzjgjWX9erEAQi2UA//ZnBZbF6yu43LNZh8SpIsZt25+kmRXpPO 24bitxkguIp8Mbf6aysizioKh10TgUzJAZL/xwzVGaf1YTtGXEiiQZvl+qetQhal CYcQUX9iRTbN3LL5sT0es8qIc9pXnVSh9YCRaa2i3l9KWlPWA2U0R4OfrAmGIjUe VG3tJ92HhtdeEx0VOHC+X6e7bDMoGQboT7cDJsP/xn8abWrBn9pQYfh7Ej/4qwMK 8sm6M7KcMcl2Sxjv0PB5obmZWBILWiTwHrJu6M3D6HBMJ4IdA0+DrDjf5U3NW6xp uYmmkKkw18juBkRyLBFG0Xnm8JUh9t50zRL5XbI5rcv8w+puqcuLuNWD83L+fIFE Z7eDdVaf0TYljefjbiZP/An2vjiOJ6Tm7nO79lrCI/g7Oax+/oK0/ClDpLuwVKtB hz7f5VrK2+q+qDRvXk65Ala9kMHvhkr7s2/64/UMcvqpnTSkzypFORSdj+UBevUb a+2ClrFEeokOXZxvZGQQxvu6do8roy2vrpLgNmxaDf65JZk5R4NlC3J4SbEjwBTT Wg4bnZRXHi+T8OL3fmPTnNsEMOAdH3kwUfgzIbj9o6wFzoZiKYRUk9qQv8jb1G9K x0qnCqtrwqzBBUs+ntXfTguTOba7JYx7aWH6ieBOIb5tapLJw7xOlVWbE1d29BCy CkeZnyNSON8=u60F -----END PGP SIGNATURE-----
-- RHSA-announce mailing list RHSA-announce@redhat.com https://listman.redhat.com/mailman/listinfo/rhsa-announce . It is comprised of the Apache Tomcat Servlet container, JBoss HTTP Connector (mod_cluster), the PicketLink Vault extension for Apache Tomcat, and the Tomcat Native library. Solution:
Before applying this update, make sure all previously released errata relevant to your system have been applied
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1464", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "graalvm", "scope": "eq", "trust": 1.0, "vendor": "oracle", "version": "20.3.1.2" }, { "model": "mysql workbench", "scope": "lte", "trust": 1.0, "vendor": "oracle", "version": "8.0.23" }, { "model": "simatic cloud connect 7", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "cloud volumes ontap mediator", "scope": "eq", "trust": 1.0, "vendor": "netapp", "version": null }, { "model": "simatic net cp 1543sp-1", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "2.1" }, { "model": "simatic pdm", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "9.1.0.7" }, { "model": "nessus network monitor", "scope": "eq", "trust": 1.0, "vendor": "tenable", "version": "5.12.1" }, { "model": "essbase", "scope": "eq", "trust": 1.0, "vendor": "oracle", "version": "21.2" }, { "model": "sma100", "scope": "gte", "trust": 1.0, "vendor": "sonicwall", "version": "10.2.0.0" }, { "model": "multi-domain management", "scope": "eq", "trust": 1.0, "vendor": "checkpoint", "version": "r80.40" }, { "model": "scalance s627-2m", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "4.1" }, { "model": "scalance xp-200", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.3" }, { "model": "simatic process historian opc ua server", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "2019" }, { "model": "node.js", "scope": "gte", "trust": 1.0, "vendor": "nodejs", "version": "10.0.0" }, { "model": "simatic cp 1242-7 gprs v2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "jd edwards world security", "scope": "eq", "trust": 1.0, "vendor": "oracle", "version": "a9.4" }, { "model": "scalance xr524-8c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.4" }, { "model": "tenable.sc", "scope": "gte", "trust": 1.0, "vendor": "tenable", "version": "5.13.0" }, { "model": "simatic rf188ci", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic net cp 1243-1", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "3.1" }, { "model": "simatic rf185c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "snapcenter", "scope": "eq", "trust": 1.0, "vendor": "netapp", "version": null }, { "model": "nessus network monitor", "scope": "eq", "trust": 1.0, "vendor": "tenable", "version": "5.13.0" }, { "model": "mysql connectors", "scope": "lte", "trust": 1.0, "vendor": "oracle", "version": "8.0.23" }, { "model": "simatic net cp 1543-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "tim 1531 irc", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.2" }, { "model": "secure global desktop", "scope": "eq", "trust": 1.0, "vendor": "oracle", "version": "5.6" }, { "model": "node.js", "scope": "lte", "trust": 1.0, "vendor": "nodejs", "version": "10.24.0" }, { "model": "mysql server", "scope": "lte", "trust": 1.0, "vendor": "oracle", "version": "5.7.33" }, { "model": "scalance xr-300wg", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.3" }, { "model": "sma100", "scope": "lt", "trust": 1.0, "vendor": "sonicwall", "version": "10.2.1.0-17sv" }, { "model": "simatic s7-1200 cpu 1217c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics connect 300", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "node.js", "scope": "lte", "trust": 1.0, "vendor": "nodejs", "version": "12.12.0" }, { "model": "nessus network monitor", "scope": "eq", "trust": 1.0, "vendor": "tenable", "version": "5.11.1" }, { "model": "peoplesoft enterprise peopletools", "scope": "eq", "trust": 1.0, "vendor": "oracle", "version": "8.58" }, { "model": "scalance xm-400", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.4" }, { "model": "simatic net cp1243-7 lte eu", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "3.1" }, { "model": "quantum security gateway", "scope": "eq", "trust": 1.0, "vendor": "checkpoint", "version": "r81" }, { "model": "communications communications policy management", "scope": "eq", "trust": 1.0, "vendor": "oracle", "version": "12.6.0.0.0" }, { "model": "simatic rf360r", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "oncommand workflow automation", "scope": "eq", "trust": 1.0, "vendor": "netapp", "version": null }, { "model": "simatic hmi comfort outdoor panels", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-1200 cpu 1214c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance s615", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "6.2" }, { "model": "mysql server", "scope": "gte", "trust": 1.0, "vendor": "oracle", "version": "8.0.15" }, { "model": "simatic mv500", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-1200 cpu 1212fc", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinec pni", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "scalance xf-200ba", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.3" }, { "model": "nessus network monitor", "scope": "eq", "trust": 1.0, "vendor": "tenable", "version": "5.12.0" }, { "model": "simatic rf188c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "zfs storage appliance kit", "scope": "eq", "trust": 1.0, "vendor": "oracle", "version": "8.8" }, { "model": "simatic s7-1200 cpu 1211c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "nessus", "scope": "lte", "trust": 1.0, "vendor": "tenable", "version": "8.13.1" }, { "model": "enterprise manager for storage management", "scope": "eq", "trust": 1.0, "vendor": "oracle", "version": "13.4.0.0" }, { "model": "multi-domain management", "scope": "eq", "trust": 1.0, "vendor": "checkpoint", "version": "r81" }, { "model": "peoplesoft enterprise peopletools", "scope": "eq", "trust": 1.0, "vendor": "oracle", "version": "8.59" }, { "model": "primavera unifier", "scope": "gte", "trust": 1.0, "vendor": "oracle", "version": "17.7" }, { "model": "simatic hmi basic panels 2nd generation", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "primavera unifier", "scope": "eq", "trust": 1.0, "vendor": "oracle", "version": "19.12" }, { "model": "scalance w700", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "6.5" }, { "model": "e-series performance analyzer", "scope": "eq", "trust": 1.0, "vendor": "netapp", "version": null }, { "model": "scalance xr552-12", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.4" }, { "model": "simatic net cp1243-7 lte us", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "3.1" }, { "model": "node.js", "scope": "gte", "trust": 1.0, "vendor": "nodejs", "version": "12.0.0" }, { "model": "openssl", "scope": "gte", "trust": 1.0, "vendor": "openssl", "version": "1.1.1" }, { "model": "fedora", "scope": "eq", "trust": 1.0, "vendor": "fedoraproject", "version": "34" }, { "model": "graalvm", "scope": "eq", "trust": 1.0, "vendor": "oracle", "version": "19.3.5" }, { "model": "primavera unifier", "scope": "eq", "trust": 1.0, "vendor": "oracle", "version": "20.12" }, { "model": "node.js", "scope": "lte", "trust": 1.0, "vendor": "nodejs", "version": "14.14.0" }, { "model": "tenable.sc", "scope": "lte", "trust": 1.0, "vendor": "tenable", "version": "5.17.0" }, { "model": "web gateway cloud service", "scope": "eq", "trust": 1.0, "vendor": "mcafee", "version": "10.1.1" }, { "model": "openssl", "scope": "lt", "trust": 1.0, "vendor": "openssl", "version": "1.1.1k" }, { "model": "simatic rf166c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "linux", "scope": "eq", "trust": 1.0, "vendor": "debian", "version": "9.0" }, { "model": "scalance xc-200", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.3" }, { "model": "simatic s7-1200 cpu 1215c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "quantum security management", "scope": "eq", "trust": 1.0, "vendor": "checkpoint", "version": "r80.40" }, { "model": "scalance xr526-8c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.4" }, { "model": "node.js", "scope": "lt", "trust": 1.0, "vendor": "nodejs", "version": "15.14.0" }, { "model": "simatic s7-1500 cpu 1518-4 pn\\/dp mfp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "linux", "scope": "eq", "trust": 1.0, "vendor": "debian", "version": "10.0" }, { "model": "web gateway cloud service", "scope": "eq", "trust": 1.0, "vendor": "mcafee", "version": "9.2.10" }, { "model": "tim 1531 irc", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "primavera unifier", "scope": "lte", "trust": 1.0, "vendor": "oracle", "version": "17.12" }, { "model": "sinec infrastructure network services", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.0.1.1" }, { "model": "graalvm", "scope": "eq", "trust": 1.0, "vendor": "oracle", "version": "21.0.0.2" }, { "model": "secure backup", "scope": "lt", "trust": 1.0, "vendor": "oracle", "version": "18.1.0.1.0" }, { "model": "nessus network monitor", "scope": "eq", "trust": 1.0, "vendor": "tenable", "version": "5.11.0" }, { "model": "storagegrid", "scope": "eq", "trust": 1.0, "vendor": "netapp", "version": null }, { "model": "peoplesoft enterprise peopletools", "scope": "eq", "trust": 1.0, "vendor": "oracle", "version": "8.57" }, { "model": "scalance sc-600", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "simatic pcs 7 telecontrol", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-1200 cpu 1215 fc", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "node.js", "scope": "lt", "trust": 1.0, "vendor": "nodejs", "version": "12.22.1" }, { "model": "simatic rf186ci", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "web gateway", "scope": "eq", "trust": 1.0, "vendor": "mcafee", "version": "10.1.1" }, { "model": "simatic net cp 1542sp-1 irc", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "2.1" }, { "model": "capture client", "scope": "eq", "trust": 1.0, "vendor": "sonicwall", "version": "3.5" }, { "model": "simatic logon", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "1.6.0.2" }, { "model": "simatic wincc telecontrol", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "active iq unified manager", "scope": "eq", "trust": 1.0, "vendor": "netapp", "version": null }, { "model": "sonicos", "scope": "eq", "trust": 1.0, "vendor": "sonicwall", "version": "7.0.1.0" }, { "model": "jd edwards enterpriseone tools", "scope": "lt", "trust": 1.0, "vendor": "oracle", "version": "9.2.6.0" }, { "model": "oncommand insight", "scope": "eq", "trust": 1.0, "vendor": "netapp", "version": null }, { "model": "simatic pcs neo", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance s623", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "4.1" }, { "model": "scalance lpe9403", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-1200 cpu 1214 fc", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "node.js", "scope": "gte", "trust": 1.0, "vendor": "nodejs", "version": "10.13.0" }, { "model": "log correlation engine", "scope": "lt", "trust": 1.0, "vendor": "tenable", "version": "6.0.9" }, { "model": "scalance m-800", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "6.2" }, { "model": "simatic rf186c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "web gateway cloud service", "scope": "eq", "trust": 1.0, "vendor": "mcafee", "version": "8.2.19" }, { "model": "node.js", "scope": "gte", "trust": 1.0, "vendor": "nodejs", "version": "14.0.0" }, { "model": "primavera unifier", "scope": "eq", "trust": 1.0, "vendor": "oracle", "version": "21.12" }, { "model": "web gateway", "scope": "eq", "trust": 1.0, "vendor": "mcafee", "version": "9.2.10" }, { "model": "node.js", "scope": "lt", "trust": 1.0, "vendor": "nodejs", "version": "14.16.1" }, { "model": "simatic hmi ktp mobile panels", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinema server", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "14.0" }, { "model": "scalance s612", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "4.1" }, { "model": "simatic s7-1200 cpu 1212c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "santricity smi-s provider", "scope": "eq", "trust": 1.0, "vendor": "netapp", "version": null }, { "model": "quantum security management", "scope": "eq", "trust": 1.0, "vendor": "checkpoint", "version": "r81" }, { "model": "scalance xr528-6m", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.4" }, { "model": "tia administrator", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinec nms", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "1.0" }, { "model": "simatic logon", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "1.5" }, { "model": "freebsd", "scope": "eq", "trust": 1.0, "vendor": "freebsd", "version": "12.2" }, { "model": "sinumerik opc ua server", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "mysql server", "scope": "lte", "trust": 1.0, "vendor": "oracle", "version": "8.0.23" }, { "model": "ontap select deploy administration utility", "scope": "eq", "trust": 1.0, "vendor": "netapp", "version": null }, { "model": "scalance xb-200", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.3" }, { "model": "scalance s602", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "4.1" }, { "model": "ruggedcom rcm1224", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "6.2" }, { "model": "node.js", "scope": "lte", "trust": 1.0, "vendor": "nodejs", "version": "10.12.0" }, { "model": "node.js", "scope": "gte", "trust": 1.0, "vendor": "nodejs", "version": "12.13.0" }, { "model": "simatic cp 1242-7 gprs v2", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "3.1" }, { "model": "web gateway", "scope": "eq", "trust": 1.0, "vendor": "mcafee", "version": "8.2.19" }, { "model": "quantum security gateway", "scope": "eq", "trust": 1.0, "vendor": "checkpoint", "version": "r80.40" }, { "model": "simatic net cp 1545-1", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "1.0" }, { "model": "simatic cloud connect 7", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "1.1" }, { "model": "node.js", "scope": "gte", "trust": 1.0, "vendor": "nodejs", "version": "15.0.0" }, { "model": "simatic net cp 1243-8 irc", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "3.1" }, { "model": "scalance w1700", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "node.js", "scope": "gte", "trust": 1.0, "vendor": "nodejs", "version": "14.15.0" }, { "model": "simatic net cp 1543-1", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "2.2" }, { "model": "hitachi ops center analyzer viewpoint", "scope": null, "trust": 0.8, "vendor": "\u65e5\u7acb", "version": null }, { "model": "storagegrid", "scope": null, "trust": 0.8, "vendor": "netapp", "version": null }, { "model": "ontap select deploy administration utility", "scope": null, "trust": 0.8, "vendor": "netapp", "version": null }, { "model": "quantum security gateway", "scope": null, "trust": 0.8, "vendor": "\u30c1\u30a7\u30c3\u30af \u30dd\u30a4\u30f3\u30c8 \u30bd\u30d5\u30c8\u30a6\u30a7\u30a2 \u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u30ba", "version": null }, { "model": "tenable.sc", "scope": null, "trust": 0.8, "vendor": "tenable", "version": null }, { "model": "nessus", "scope": null, "trust": 0.8, "vendor": "tenable", "version": null }, { "model": "oncommand workflow automation", "scope": null, "trust": 0.8, "vendor": "netapp", "version": null }, { "model": "freebsd", "scope": null, "trust": 0.8, "vendor": "freebsd", "version": null }, { "model": "hitachi ops center common services", "scope": null, "trust": 0.8, "vendor": "\u65e5\u7acb", "version": null }, { "model": "santricity smi-s provider", "scope": null, "trust": 0.8, "vendor": "netapp", "version": null }, { "model": "mcafee web gateway \u30bd\u30d5\u30c8\u30a6\u30a7\u30a2", "scope": null, "trust": 0.8, "vendor": "\u30de\u30ab\u30d5\u30a3\u30fc", "version": null }, { "model": "e-series performance analyzer", "scope": null, "trust": 0.8, "vendor": "netapp", "version": null }, { "model": "fedora", "scope": null, "trust": 0.8, "vendor": "fedora", "version": null }, { "model": "jp1/file transmission server/ftp", "scope": null, "trust": 0.8, "vendor": "\u65e5\u7acb", "version": null }, { "model": "quantum security management", "scope": null, "trust": 0.8, "vendor": "\u30c1\u30a7\u30c3\u30af \u30dd\u30a4\u30f3\u30c8 \u30bd\u30d5\u30c8\u30a6\u30a7\u30a2 \u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u30ba", "version": null }, { "model": "openssl", "scope": null, "trust": 0.8, "vendor": "openssl", "version": null }, { "model": "cloud volumes ontap \u30e1\u30c7\u30a3\u30a8\u30fc\u30bf", "scope": null, "trust": 0.8, "vendor": "netapp", "version": null }, { "model": "jp1/base", "scope": null, "trust": 0.8, "vendor": "\u65e5\u7acb", "version": null }, { "model": "gnu/linux", "scope": null, "trust": 0.8, "vendor": "debian", "version": null }, { "model": "web gateway cloud service", "scope": null, "trust": 0.8, "vendor": "\u30de\u30ab\u30d5\u30a3\u30fc", "version": null }, { "model": "multi-domain management", "scope": null, "trust": 0.8, "vendor": "\u30c1\u30a7\u30c3\u30af \u30dd\u30a4\u30f3\u30c8 \u30bd\u30d5\u30c8\u30a6\u30a7\u30a2 \u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u30ba", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-001383" }, { "db": "NVD", "id": "CVE-2021-3449" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Red Hat", "sources": [ { "db": "PACKETSTORM", "id": "162694" }, { "db": "PACKETSTORM", "id": "163257" }, { "db": "PACKETSTORM", "id": "162383" }, { "db": "PACKETSTORM", "id": "162076" }, { "db": "PACKETSTORM", "id": "162013" }, { "db": "PACKETSTORM", "id": "162200" }, { "db": "PACKETSTORM", "id": "162197" }, { "db": "PACKETSTORM", "id": "162189" } ], "trust": 0.8 }, "cve": "CVE-2021-3449", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 4.3, "confidentialityImpact": "NONE", "exploitabilityScore": 8.6, "id": "CVE-2021-3449", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 4.3, "confidentialityImpact": "NONE", "exploitabilityScore": 8.6, "id": "VHN-388130", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:M/AU:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "HIGH", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 2.2, "id": "CVE-2021-3449", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "High", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 5.9, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-3449", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-3449", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2021-3449", "trust": 0.8, "value": "Medium" }, { "author": "VULHUB", "id": "VHN-388130", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-388130" }, { "db": "JVNDB", "id": "JVNDB-2021-001383" }, { "db": "NVD", "id": "CVE-2021-3449" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j). The product supports a variety of encryption algorithms, including symmetric ciphers, hash algorithms, secure hash algorithms, etc. Summary:\n\nOpenshift Serverless 1.10.2 is now available. This version of the OpenShift Serverless\nOperator is supported on Red Hat OpenShift Container Platform version 4.5. Solution:\n\nSee the documentation at:\nhttps://access.redhat.com/documentation/en-us/openshift_container_platform/\n4.5/html/serverless_applications/index\n\n4. \n\nBug Fix(es):\n\n* WMCO patch pub-key-hash annotation to Linux node (BZ#1945248)\n\n* LoadBalancer Service type with invalid external loadbalancer IP breaks\nthe datapath (BZ#1952917)\n\n* Telemetry info not completely available to identify windows nodes\n(BZ#1955319)\n\n* WMCO incorrectly shows node as ready after a failed configuration\n(BZ#1956412)\n\n* kube-proxy service terminated unexpectedly after recreated LB service\n(BZ#1963263)\n\n3. Solution:\n\nFor Windows Machine Config Operator upgrades, see the following\ndocumentation:\n\nhttps://docs.openshift.com/container-platform/4.7/windows_containers/window\ns-node-upgrades.html\n\n4. Bugs fixed (https://bugzilla.redhat.com/):\n\n1945248 - WMCO patch pub-key-hash annotation to Linux node\n1946538 - CVE-2021-25736 kubernetes: LoadBalancer Service type don\u0027t create a HNS policy for empty or invalid external loadbalancer IP, what could lead to MITM\n1952917 - LoadBalancer Service type with invalid external loadbalancer IP breaks the datapath\n1955319 - Telemetry info not completely available to identify windows nodes\n1956412 - WMCO incorrectly shows node as ready after a failed configuration\n1963263 - kube-proxy service terminated unexpectedly after recreated LB service\n\n5. Description:\n\nRed Hat Advanced Cluster Management for Kubernetes 2.0.10 images\n\nRed Hat Advanced Cluster Management for Kubernetes provides the\ncapabilities to address common challenges that administrators and site\nreliability engineers face as they work across a range of public and\nprivate cloud environments. Clusters and applications are all visible and\nmanaged from a single console\u2014with security policy built in. \n\nBug fix:\n\n* RHACM 2.0.10 images (BZ #1940452)\n\n3. Bugs fixed (https://bugzilla.redhat.com/):\n\n1940452 - RHACM 2.0.10 images\n1944286 - CVE-2021-23358 nodejs-underscore: Arbitrary code execution via the template function\n\n5. ==========================================================================\nUbuntu Security Notice USN-4891-1\nMarch 25, 2021\n\nopenssl vulnerability\n==========================================================================\n\nA security issue affects these releases of Ubuntu and its derivatives:\n\n- Ubuntu 20.10\n- Ubuntu 20.04 LTS\n- Ubuntu 18.04 LTS\n\nSummary:\n\nOpenSSL could be made to crash or run programs if it received specially\ncrafted network traffic. A remote attacker could use this issue to cause\nOpenSSL to crash, resulting in a denial of service, or possibly execute\narbitrary code. \n\nUpdate instructions:\n\nThe problem can be corrected by updating your system to the following\npackage versions:\n\nUbuntu 20.10:\n libssl1.1 1.1.1f-1ubuntu4.3\n\nUbuntu 20.04 LTS:\n libssl1.1 1.1.1f-1ubuntu2.3\n\nUbuntu 18.04 LTS:\n libssl1.1 1.1.1-1ubuntu2.1~18.04.9\n\nAfter a standard system update you need to reboot your computer to make\nall the necessary changes. 8) - aarch64, ppc64le, s390x, x86_64\n\n3. Description:\n\nOpenSSL is a toolkit that implements the Secure Sockets Layer (SSL) and\nTransport Layer Security (TLS) protocols, as well as a full-strength\ngeneral-purpose cryptography library. Solution:\n\nFor details on how to apply this update, which includes the changes\ndescribed in this advisory, refer to:\n\nhttps://access.redhat.com/articles/11258\n\nFor the update to take effect, all services linked to the OpenSSL library\nmust be restarted, or the system rebooted. Package List:\n\nRed Hat Enterprise Linux BaseOS (v. Our key and\ndetails on how to verify the signature are available from\nhttps://access.redhat.com/security/team/key/\n\n7. -----BEGIN PGP SIGNED MESSAGE-----\nHash: SHA256\n\n==================================================================== \nRed Hat Security Advisory\n\nSynopsis: Important: Red Hat JBoss Core Services Apache HTTP Server 2.4.37 SP7 security update\nAdvisory ID: RHSA-2021:1200-01\nProduct: Red Hat JBoss Core Services\nAdvisory URL: https://access.redhat.com/errata/RHSA-2021:1200\nIssue date: 2021-04-14\nCVE Names: CVE-2021-3449 CVE-2021-3450\n====================================================================\n1. Summary:\n\nRed Hat JBoss Core Services Pack Apache Server 2.4.37 Service Pack 7 zip\nrelease for RHEL 7, RHEL 8 and Microsoft Windows is available. \n\nRed Hat Product Security has rated this update as having a security impact\nof Important. A Common Vulnerability Scoring System (CVSS) base score,\nwhich gives a detailed severity rating, is available for each vulnerability\nfrom the CVE link(s) in the References section. \n\n2. Description:\n\nRed Hat JBoss Core Services is a set of supplementary software for Red Hat\nJBoss middleware products. This software, such as Apache HTTP Server, is\ncommon to multiple JBoss middleware products, and is packaged under Red Hat\nJBoss Core Services to allow for faster distribution of updates, and for a\nmore consistent update experience. \n\nThis release adds the new Apache HTTP Server 2.4.37 Service Pack 7 packages\nthat are part of the JBoss Core Services offering. \n\nThis release serves as a replacement for Red Hat JBoss Core Services Pack\nApache Server 2.4.37 Service Pack 6 and includes bug fixes and\nenhancements. Refer to the Release Notes for information on the most\nsignificant bug fixes and enhancements included in this release. \n\nSecurity fix(es):\n\n* openssl: NULL pointer deref in signature_algorithms processing\n(CVE-2021-3449)\n\n* openssl: CA certificate check bypass with X509_V_FLAG_X509_STRICT\n(CVE-2021-3450)\n\nFor more details about the security issue(s), including the impact, a CVSS\nscore, acknowledgments, and other related information, refer to the CVE\npage(s) listed in the References section. \n\n3. Solution:\n\nBefore applying the update, back up your existing installation, including\nall applications, configuration files, databases and database settings, and\nso on. \n\nThe References section of this erratum contains a download link for the\nupdate. You must be logged in to download the update. \n\n4. Bugs fixed (https://bugzilla.redhat.com/):\n\n1941547 - CVE-2021-3450 openssl: CA certificate check bypass with X509_V_FLAG_X509_STRICT\n1941554 - CVE-2021-3449 openssl: NULL pointer dereference in signature_algorithms processing\n\n5. References:\n\nhttps://access.redhat.com/security/cve/CVE-2021-3449\nhttps://access.redhat.com/security/cve/CVE-2021-3450\nhttps://access.redhat.com/security/updates/classification/#important\nhttps://access.redhat.com/jbossnetwork/restricted/listSoftware.html?product=core.service.apachehttp\u0026downloadType=securityPatches\u0026version=2.4.37\n\n6. Contact:\n\nThe Red Hat security contact is \u003csecalert@redhat.com\u003e. More contact\ndetails at https://access.redhat.com/security/team/contact/\n\nCopyright 2021 Red Hat, Inc. \n-----BEGIN PGP SIGNATURE-----\nVersion: GnuPG v1\n\niQIVAwUBYHcRztzjgjWX9erEAQi2UA//ZnBZbF6yu43LNZh8SpIsZt25+kmRXpPO\n24bitxkguIp8Mbf6aysizioKh10TgUzJAZL/xwzVGaf1YTtGXEiiQZvl+qetQhal\nCYcQUX9iRTbN3LL5sT0es8qIc9pXnVSh9YCRaa2i3l9KWlPWA2U0R4OfrAmGIjUe\nVG3tJ92HhtdeEx0VOHC+X6e7bDMoGQboT7cDJsP/xn8abWrBn9pQYfh7Ej/4qwMK\n8sm6M7KcMcl2Sxjv0PB5obmZWBILWiTwHrJu6M3D6HBMJ4IdA0+DrDjf5U3NW6xp\nuYmmkKkw18juBkRyLBFG0Xnm8JUh9t50zRL5XbI5rcv8w+puqcuLuNWD83L+fIFE\nZ7eDdVaf0TYljefjbiZP/An2vjiOJ6Tm7nO79lrCI/g7Oax+/oK0/ClDpLuwVKtB\nhz7f5VrK2+q+qDRvXk65Ala9kMHvhkr7s2/64/UMcvqpnTSkzypFORSdj+UBevUb\na+2ClrFEeokOXZxvZGQQxvu6do8roy2vrpLgNmxaDf65JZk5R4NlC3J4SbEjwBTT\nWg4bnZRXHi+T8OL3fmPTnNsEMOAdH3kwUfgzIbj9o6wFzoZiKYRUk9qQv8jb1G9K\nx0qnCqtrwqzBBUs+ntXfTguTOba7JYx7aWH6ieBOIb5tapLJw7xOlVWbE1d29BCy\nCkeZnyNSON8=u60F\n-----END PGP SIGNATURE-----\n\n--\nRHSA-announce mailing list\nRHSA-announce@redhat.com\nhttps://listman.redhat.com/mailman/listinfo/rhsa-announce\n. It is comprised of the Apache\nTomcat Servlet container, JBoss HTTP Connector (mod_cluster), the\nPicketLink Vault extension for Apache Tomcat, and the Tomcat Native\nlibrary. Solution:\n\nBefore applying this update, make sure all previously released errata\nrelevant to your system have been applied", "sources": [ { "db": "NVD", "id": "CVE-2021-3449" }, { "db": "JVNDB", "id": "JVNDB-2021-001383" }, { "db": "VULHUB", "id": "VHN-388130" }, { "db": "PACKETSTORM", "id": "162694" }, { "db": "PACKETSTORM", "id": "163257" }, { "db": "PACKETSTORM", "id": "162383" }, { "db": "PACKETSTORM", "id": "162076" }, { "db": "PACKETSTORM", "id": "161984" }, { "db": "PACKETSTORM", "id": "162013" }, { "db": "PACKETSTORM", "id": "162200" }, { "db": "PACKETSTORM", "id": "162197" }, { "db": "PACKETSTORM", "id": "162189" } ], "trust": 2.52 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-3449", "trust": 2.8 }, { "db": "TENABLE", "id": "TNS-2021-06", "trust": 1.1 }, { "db": "TENABLE", "id": "TNS-2021-09", "trust": 1.1 }, { "db": "TENABLE", "id": "TNS-2021-05", "trust": 1.1 }, { "db": "TENABLE", "id": "TNS-2021-10", "trust": 1.1 }, { "db": "OPENWALL", "id": "OSS-SECURITY/2021/03/28/3", "trust": 1.1 }, { "db": "OPENWALL", "id": "OSS-SECURITY/2021/03/27/2", "trust": 1.1 }, { "db": "OPENWALL", "id": "OSS-SECURITY/2021/03/28/4", "trust": 1.1 }, { "db": "OPENWALL", "id": "OSS-SECURITY/2021/03/27/1", "trust": 1.1 }, { "db": "SIEMENS", "id": "SSA-772220", "trust": 1.1 }, { "db": "SIEMENS", "id": "SSA-389290", "trust": 1.1 }, { "db": "PULSESECURE", "id": "SA44845", "trust": 1.1 }, { "db": "MCAFEE", "id": "SB10356", "trust": 1.1 }, { "db": "JVN", "id": "JVNVU92126369", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-001383", "trust": 0.8 }, { "db": "PACKETSTORM", "id": "162197", "trust": 0.2 }, { "db": "PACKETSTORM", "id": "162076", "trust": 0.2 }, { "db": "PACKETSTORM", "id": "163257", "trust": 0.2 }, { "db": "PACKETSTORM", "id": "162013", "trust": 0.2 }, { "db": "PACKETSTORM", "id": "162383", "trust": 0.2 }, { "db": "PACKETSTORM", "id": "162189", "trust": 0.2 }, { "db": "PACKETSTORM", "id": "161984", "trust": 0.2 }, { "db": "PACKETSTORM", "id": "162200", "trust": 0.2 }, { "db": "PACKETSTORM", "id": "162114", "trust": 0.1 }, { "db": "PACKETSTORM", "id": "162350", "trust": 0.1 }, { "db": "PACKETSTORM", "id": "162041", "trust": 0.1 }, { "db": "PACKETSTORM", "id": "162183", "trust": 0.1 }, { "db": "PACKETSTORM", "id": "162699", "trust": 0.1 }, { "db": "PACKETSTORM", "id": "162337", "trust": 0.1 }, { "db": "PACKETSTORM", "id": "162151", "trust": 0.1 }, { "db": "PACKETSTORM", "id": "162196", "trust": 0.1 }, { "db": "PACKETSTORM", "id": "162172", "trust": 0.1 }, { "db": "PACKETSTORM", "id": "162201", "trust": 0.1 }, { "db": "PACKETSTORM", "id": "162307", "trust": 0.1 }, { "db": "SEEBUG", "id": "SSVID-99170", "trust": 0.1 }, { "db": "VULHUB", "id": "VHN-388130", "trust": 0.1 }, { "db": "PACKETSTORM", "id": "162694", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-388130" }, { "db": "JVNDB", "id": "JVNDB-2021-001383" }, { "db": "PACKETSTORM", "id": "162694" }, { "db": "PACKETSTORM", "id": "163257" }, { "db": "PACKETSTORM", "id": "162383" }, { "db": "PACKETSTORM", "id": "162076" }, { "db": "PACKETSTORM", "id": "161984" }, { "db": "PACKETSTORM", "id": "162013" }, { "db": "PACKETSTORM", "id": "162200" }, { "db": "PACKETSTORM", "id": "162197" }, { "db": "PACKETSTORM", "id": "162189" }, { "db": "NVD", "id": "CVE-2021-3449" } ] }, "id": "VAR-202103-1464", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-388130" } ], "trust": 0.6742040990624999 }, "last_update_date": "2024-11-29T22:12:22.747000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "hitachi-sec-2021-119 Software product security information", "trust": 0.8, "url": "https://www.debian.org/security/2021/dsa-4875" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-001383" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-476", "trust": 1.1 }, { "problemtype": "NULL Pointer dereference (CWE-476) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "VULHUB", "id": "VHN-388130" }, { "db": "JVNDB", "id": "JVNDB-2021-001383" }, { "db": "NVD", "id": "CVE-2021-3449" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-3449" }, { "trust": 1.1, "url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-openssl-2021-ghy28djd" }, { "trust": 1.1, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf" }, { "trust": 1.1, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf" }, { "trust": 1.1, "url": "https://kb.pulsesecure.net/articles/pulse_security_advisories/sa44845" }, { "trust": 1.1, "url": "https://psirt.global.sonicwall.com/vuln-detail/snwlid-2021-0013" }, { "trust": 1.1, "url": "https://security.netapp.com/advisory/ntap-20210326-0006/" }, { "trust": 1.1, "url": "https://security.netapp.com/advisory/ntap-20210513-0002/" }, { "trust": 1.1, "url": "https://www.openssl.org/news/secadv/20210325.txt" }, { "trust": 1.1, "url": "https://www.tenable.com/security/tns-2021-05" }, { "trust": 1.1, "url": "https://www.tenable.com/security/tns-2021-06" }, { "trust": 1.1, "url": "https://www.tenable.com/security/tns-2021-09" }, { "trust": 1.1, "url": "https://www.tenable.com/security/tns-2021-10" }, { "trust": 1.1, "url": "https://www.debian.org/security/2021/dsa-4875" }, { "trust": 1.1, "url": "https://security.gentoo.org/glsa/202103-03" }, { "trust": 1.1, "url": "https://security.freebsd.org/advisories/freebsd-sa-21:07.openssl.asc" }, { "trust": 1.1, "url": "https://www.oracle.com//security-alerts/cpujul2021.html" }, { "trust": 1.1, "url": "https://www.oracle.com/security-alerts/cpuapr2021.html" }, { "trust": 1.1, "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" }, { "trust": 1.1, "url": "https://www.oracle.com/security-alerts/cpujul2022.html" }, { "trust": 1.1, "url": "https://www.oracle.com/security-alerts/cpuoct2021.html" }, { "trust": 1.1, "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html" }, { "trust": 1.1, "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1" }, { "trust": 1.1, "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2" }, { "trust": 1.1, "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3" }, { "trust": 1.1, "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4" }, { "trust": 1.0, "url": "https://git.openssl.org/gitweb/?p=openssl.git%3ba=commitdiff%3bh=fb9fa6b51defd48157eeb207f52181f735d96148" }, { "trust": 1.0, "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/ccbfllvqvilivgzmbjl3ixzgkwqisynp/" }, { "trust": 1.0, "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=sb10356" }, { "trust": 1.0, "url": "https://security.netapp.com/advisory/ntap-20240621-0006/" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu92126369/" }, { "trust": 0.8, "url": "https://listman.redhat.com/mailman/listinfo/rhsa-announce" }, { "trust": 0.8, "url": "https://access.redhat.com/security/team/contact/" }, { "trust": 0.8, "url": "https://access.redhat.com/security/cve/cve-2021-3449" }, { "trust": 0.8, "url": "https://bugzilla.redhat.com/):" }, { "trust": 0.7, "url": "https://access.redhat.com/security/cve/cve-2021-3450" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-3450" }, { "trust": 0.5, "url": "https://access.redhat.com/security/updates/classification/#important" }, { "trust": 0.3, "url": "https://access.redhat.com/security/cve/cve-2021-20305" }, { "trust": 0.3, "url": "https://access.redhat.com/security/updates/classification/#moderate" }, { "trust": 0.3, "url": "https://access.redhat.com/security/team/key/" }, { "trust": 0.3, "url": "https://access.redhat.com/articles/11258" }, { "trust": 0.2, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-20305" }, { "trust": 0.1, "url": "https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=fb9fa6b51defd48157eeb207f52181f735d96148" }, { "trust": 0.1, "url": "https://kc.mcafee.com/corporate/index?page=content\u0026amp;id=sb10356" }, { "trust": 0.1, "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/ccbfllvqvilivgzmbjl3ixzgkwqisynp/" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2019-20454" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-20916" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-19221" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-20907" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-19906" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-13050" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2019-20907" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-13631" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14422" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-7595" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-13632" }, { "trust": 0.1, "url": "https://access.redhat.com/documentation/en-us/openshift_container_platform/" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-8492" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2019-16168" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-9327" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-13630" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2019-20387" }, { "trust": 0.1, "url": "https://access.redhat.com/documentation/en-us/openshift_container_platform/4.5/html/serverless_applications/index" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-5018" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-20218" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2018-1000858" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2021-3115" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2019-13050" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2019-14889" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-1730" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-9327" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2019-16935" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2019-19906" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2019-13627" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2019-19221" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-6405" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2019-20388" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2021-3114" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-20843" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-1000858" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-20388" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-15903" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2018-20843" }, { "trust": 0.1, "url": "https://access.redhat.com/errata/rhsa-2021:2021" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-13631" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-20387" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-8492" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2019-5018" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2019-19956" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-13632" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2019-15903" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-14422" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-13627" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-13630" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-14889" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-1730" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-6405" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-19956" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-16935" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2019-20218" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-20454" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-7595" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-16168" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2019-20916" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2019-25013" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-29362" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-25736" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-29361" }, { "trust": 0.1, "url": "https://access.redhat.com/errata/rhsa-2021:2130" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2019-2708" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-8286" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-8284" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-28196" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-15358" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-27219" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-15358" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-8927" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-13434" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2017-14502" }, { "trust": 0.1, "url": "https://docs.openshift.com/container-platform/4.7/windows_containers/window" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-29362" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-8285" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-8285" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2017-14502" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-8286" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-29363" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2019-9169" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2016-10228" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-27618" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-8927" }, { "trust": 0.1, "url": "https://issues.jboss.org/):" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-3842" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-13434" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-3326" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2021-25736" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-2708" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-13776" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2016-10228" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-29363" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-24977" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2019-3842" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-13776" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-25013" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-8231" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-9169" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2021-3326" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-8231" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2021-27219" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-8284" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-24977" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-29361" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-27618" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-28196" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2021-23358" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-27363" }, { "trust": 0.1, "url": "https://access.redhat.com/documentation/en-us/red_hat_advanced_cluster_mana" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-15586" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2021-3347" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-28374" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-28362" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-23358" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2021-27364" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-26708" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-27365" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-0466" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-27152" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2021-27363" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-16845" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-27152" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-3347" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-16845" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2021-27365" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-0466" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2020-28362" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-15586" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-27364" }, { "trust": 0.1, "url": "https://access.redhat.com/errata/rhsa-2021:1448" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-28374" }, { "trust": 0.1, "url": "https://access.redhat.com/security/cve/cve-2021-26708" }, { "trust": 0.1, "url": "https://access.redhat.com/errata/rhsa-2021:1063" }, { "trust": 0.1, "url": "https://launchpad.net/ubuntu/+source/openssl/1.1.1-1ubuntu2.1~18.04.9" }, { "trust": 0.1, "url": "https://launchpad.net/ubuntu/+source/openssl/1.1.1f-1ubuntu4.3" }, { "trust": 0.1, "url": "https://ubuntu.com/security/notices/usn-4891-1" }, { "trust": 0.1, "url": "https://launchpad.net/ubuntu/+source/openssl/1.1.1f-1ubuntu2.3" }, { "trust": 0.1, "url": "https://access.redhat.com/errata/rhsa-2021:1024" }, { "trust": 0.1, "url": "https://access.redhat.com/errata/rhsa-2021:1203" }, { "trust": 0.1, "url": "https://access.redhat.com/errata/rhsa-2021:1200" }, { "trust": 0.1, "url": "https://access.redhat.com/jbossnetwork/restricted/listsoftware.html?product=core.service.apachehttp\u0026downloadtype=securitypatches\u0026version=2.4.37" }, { "trust": 0.1, "url": "https://access.redhat.com/errata/rhsa-2021:1195" } ], "sources": [ { "db": "VULHUB", "id": "VHN-388130" }, { "db": "JVNDB", "id": "JVNDB-2021-001383" }, { "db": "PACKETSTORM", "id": "162694" }, { "db": "PACKETSTORM", "id": "163257" }, { "db": "PACKETSTORM", "id": "162383" }, { "db": "PACKETSTORM", "id": "162076" }, { "db": "PACKETSTORM", "id": "161984" }, { "db": "PACKETSTORM", "id": "162013" }, { "db": "PACKETSTORM", "id": "162200" }, { "db": "PACKETSTORM", "id": "162197" }, { "db": "PACKETSTORM", "id": "162189" }, { "db": "NVD", "id": "CVE-2021-3449" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-388130" }, { "db": "JVNDB", "id": "JVNDB-2021-001383" }, { "db": "PACKETSTORM", "id": "162694" }, { "db": "PACKETSTORM", "id": "163257" }, { "db": "PACKETSTORM", "id": "162383" }, { "db": "PACKETSTORM", "id": "162076" }, { "db": "PACKETSTORM", "id": "161984" }, { "db": "PACKETSTORM", "id": "162013" }, { "db": "PACKETSTORM", "id": "162200" }, { "db": "PACKETSTORM", "id": "162197" }, { "db": "PACKETSTORM", "id": "162189" }, { "db": "NVD", "id": "CVE-2021-3449" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-25T00:00:00", "db": "VULHUB", "id": "VHN-388130" }, { "date": "2021-05-06T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-001383" }, { "date": "2021-05-19T14:19:18", "db": "PACKETSTORM", "id": "162694" }, { "date": "2021-06-23T15:44:15", "db": "PACKETSTORM", "id": "163257" }, { "date": "2021-04-29T14:37:49", "db": "PACKETSTORM", "id": "162383" }, { "date": "2021-04-05T15:16:03", "db": "PACKETSTORM", "id": "162076" }, { "date": "2021-03-26T14:15:18", "db": "PACKETSTORM", "id": "161984" }, { "date": "2021-03-30T14:07:13", "db": "PACKETSTORM", "id": "162013" }, { "date": "2021-04-15T13:50:30", "db": "PACKETSTORM", "id": "162200" }, { "date": "2021-04-15T13:50:04", "db": "PACKETSTORM", "id": "162197" }, { "date": "2021-04-14T16:50:04", "db": "PACKETSTORM", "id": "162189" }, { "date": "2021-03-25T15:15:13.450000", "db": "NVD", "id": "CVE-2021-3449" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-08-29T00:00:00", "db": "VULHUB", "id": "VHN-388130" }, { "date": "2021-09-13T07:43:00", "db": "JVNDB", "id": "JVNDB-2021-001383" }, { "date": "2024-11-21T06:21:33.050000", "db": "NVD", "id": "CVE-2021-3449" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "PACKETSTORM", "id": "161984" } ], "trust": 0.1 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "OpenSSL\u00a0 In \u00a0NULL\u00a0 Pointer dereference vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-001383" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "code execution", "sources": [ { "db": "PACKETSTORM", "id": "162694" }, { "db": "PACKETSTORM", "id": "162383" } ], "trust": 0.2 } }
var-202409-0271
Vulnerability from variot
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-7 LTE (All versions < V3.5.20), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.5.20), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC WinCC Runtime Advanced (All versions), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.4.8). The web server of the affected devices do not properly handle certain requests, causing a timeout in the watchdog, which could lead to the clean up of pointers.
This could allow a remote attacker to cause a denial of service condition in the system. SIMATIC CP 1242 and CP 1243 related processors connect SIMATIC S7-1200 controllers to wide area networks (WANs). They offer integrated security features such as firewalls, virtual private networks (VPNs) and support for other data encryption protocols. SIMATIC HMI Panels are used for operator control and monitoring of machines and plants. SIMATIC IPC DiagBase diagnostics software allows early identification of any potential faults on SIMATIC industrial computers and helps to avoid or reduce system downtime. SIMATIC IPC DiagMonitor monitors, reports, visualizes and logs the system status of SIMATIC IPCs. It communicates with other systems and reacts when events occur. Communication processor (CP) modules SIMATIC TIM 3V-IE and TIM 4R-IE are designed to enable Ethernet or telecontrol communication for SIMATIC S7-300/S7-400 CPUs. SIMATIC WinCC Runtime Advanced is a visualization runtime platform for operator control and monitoring of machines and plants. SIPLUS extreme products are designed for reliable operation under extreme conditions and are based on SIMATIC, LOGO!, SITOP, SINAMICS, SIMOTION, SCALANCE or other devices. SIPLUS devices use the same firmware as the products they are based on
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202409-0271", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic ipc diagmonitor", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic ipc diagbase", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "siplus tim irc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1531\u003cv2.4.8" }, { "model": "tim irc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1531\u003cv2.4.8" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1242-7v2\u003cv3.5.20" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1243-1\u003cv3.5.20" }, { "model": "simatic cp dnp3", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1243-1\u003cv3.5.20" }, { "model": "simatic cp iec", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1243-1\u003cv3.5.20" }, { "model": "simatic cp lte", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1243-7\u003cv3.5.20" }, { "model": "simatic cp irc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1243-8\u003cv3.5.20" }, { "model": "simatic hmi comfort panels", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-38017" } ] }, "cve": "CVE-2023-28827", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "HIGH", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 5.4, "confidentialityImpact": "NONE", "exploitabilityScore": 4.9, "id": "CNVD-2024-38017", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:H/Au:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "HIGH", "attackVector": "NETWORK", "author": "productcert@siemens.com", "availabilityImpact": "HIGH", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 2.2, "id": "CVE-2023-28827", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } ], "severity": [ { "author": "productcert@siemens.com", "id": "CVE-2023-28827", "trust": 1.0, "value": "High" }, { "author": "CNVD", "id": "CNVD-2024-38017", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-38017" }, { "db": "NVD", "id": "CVE-2023-28827" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-7 LTE (All versions \u003c V3.5.20), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.5.20), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC WinCC Runtime Advanced (All versions), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.4.8). The web server of the affected devices do not properly handle certain requests, causing a timeout in the watchdog, which could lead to the clean up of pointers. \r\n\r\nThis could allow a remote attacker to cause a denial of service condition in the system. SIMATIC CP 1242 and CP 1243 related processors connect SIMATIC S7-1200 controllers to wide area networks (WANs). They offer integrated security features such as firewalls, virtual private networks (VPNs) and support for other data encryption protocols. SIMATIC HMI Panels are used for operator control and monitoring of machines and plants. SIMATIC IPC DiagBase diagnostics software allows early identification of any potential faults on SIMATIC industrial computers and helps to avoid or reduce system downtime. SIMATIC IPC DiagMonitor monitors, reports, visualizes and logs the system status of SIMATIC IPCs. It communicates with other systems and reacts when events occur. Communication processor (CP) modules SIMATIC TIM 3V-IE and TIM 4R-IE are designed to enable Ethernet or telecontrol communication for SIMATIC S7-300/S7-400 CPUs. SIMATIC WinCC Runtime Advanced is a visualization runtime platform for operator control and monitoring of machines and plants. SIPLUS extreme products are designed for reliable operation under extreme conditions and are based on SIMATIC, LOGO!, SITOP, SINAMICS, SIMOTION, SCALANCE or other devices. SIPLUS devices use the same firmware as the products they are based on", "sources": [ { "db": "NVD", "id": "CVE-2023-28827" }, { "db": "CNVD", "id": "CNVD-2024-38017" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-28827", "trust": 1.6 }, { "db": "SIEMENS", "id": "SSA-423808", "trust": 1.6 }, { "db": "CNVD", "id": "CNVD-2024-38017", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-38017" }, { "db": "NVD", "id": "CVE-2023-28827" } ] }, "id": "VAR-202409-0271", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-38017" } ], "trust": 1.364781105 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-38017" } ] }, "last_update_date": "2024-09-13T23:28:46.324000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens Industrial Products Null Pointer Dereference Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/590301" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-38017" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-476", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2023-28827" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-423808.html" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-38017" }, { "db": "NVD", "id": "CVE-2023-28827" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-38017" }, { "db": "NVD", "id": "CVE-2023-28827" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-09-12T00:00:00", "db": "CNVD", "id": "CNVD-2024-38017" }, { "date": "2024-09-10T10:15:05.347000", "db": "NVD", "id": "CVE-2023-28827" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-09-12T00:00:00", "db": "CNVD", "id": "CNVD-2024-38017" }, { "date": "2024-09-10T12:09:50.377000", "db": "NVD", "id": "CVE-2023-28827" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens Industrial Products Null Pointer Dereference Vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2024-38017" } ], "trust": 0.6 } }
var-202105-0690
Vulnerability from variot
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution. Several Siemens products are vulnerable to access to memory areas after buffer termination.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Siemens SmartVNC is an industrial control equipment of Siemens (Siemens), Germany.
Siemens SmartVNC has an out-of-bounds memory access vulnerability. Remote attackers can use the vulnerability to submit special requests, which can crash the application or execute arbitrary code in the context of the application. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202105-0690", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics sl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinamics gm150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic wincc runtime advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinamics sm150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinamics sm150i", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic wincc runtime advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gh150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics sm120", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics sh150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics sh150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sl150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sm120", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sm150i", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi comfort outdoor panels 7\"", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics gh150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sm150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics gl150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics gm150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "smartvnc", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37750" }, { "db": "JVNDB", "id": "JVNDB-2021-006949" }, { "db": "NVD", "id": "CVE-2021-27384" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-548" } ], "trust": 0.6 }, "cve": "CVE-2021-27384", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2021-27384", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CNVD-2021-37750", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-27384", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-27384", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-27384", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2021-27384", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2021-37750", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202105-548", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-27384", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37750" }, { "db": "VULMON", "id": "CVE-2021-27384" }, { "db": "JVNDB", "id": "JVNDB-2021-006949" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-548" }, { "db": "NVD", "id": "CVE-2021-27384" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution. Several Siemens products are vulnerable to access to memory areas after buffer termination.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Siemens SmartVNC is an industrial control equipment of Siemens (Siemens), Germany. \n\r\n\r\nSiemens SmartVNC has an out-of-bounds memory access vulnerability. Remote attackers can use the vulnerability to submit special requests, which can crash the application or execute arbitrary code in the context of the application. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements", "sources": [ { "db": "NVD", "id": "CVE-2021-27384" }, { "db": "JVNDB", "id": "JVNDB-2021-006949" }, { "db": "CNVD", "id": "CNVD-2021-37750" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULMON", "id": "CVE-2021-27384" } ], "trust": 2.79 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-27384", "trust": 3.9 }, { "db": "ICS CERT", "id": "ICSA-21-131-11", "trust": 2.5 }, { "db": "SIEMENS", "id": "SSA-286838", "trust": 1.7 }, { "db": "SIEMENS", "id": "SSA-538778", "trust": 1.6 }, { "db": "ICS CERT", "id": "ICSA-21-131-12", "trust": 1.2 }, { "db": "JVN", "id": "JVNVU91051134", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-006949", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-37750", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021051206", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-21-131-04", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202105-548", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-27384", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37750" }, { "db": "VULMON", "id": "CVE-2021-27384" }, { "db": "JVNDB", "id": "JVNDB-2021-006949" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-548" }, { "db": "NVD", "id": "CVE-2021-27384" } ] }, "id": "VAR-202105-0690", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-37750" } ], "trust": 1.205898611111111 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37750" } ] }, "last_update_date": "2024-08-14T13:12:43.619000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-286838 Siemens\u00a0Security\u00a0Advisory", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "title": "Patch for Siemens SmartVNC memory out-of-bounds access vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/268666" }, { "title": "Siemens SmartVNC Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=155975" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=43c9c77785b8d29daef02185f41ca476" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=9465a8ef1f8c1b0042244cb02cfe271e" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37750" }, { "db": "VULMON", "id": "CVE-2021-27384" }, { "db": "JVNDB", "id": "JVNDB-2021-006949" }, { "db": "CNNVD", "id": "CNNVD-202105-548" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-788", "trust": 1.0 }, { "problemtype": "Access to memory area after buffer termination (CWE-788) [ Other ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006949" }, { "db": "NVD", "id": "CVE-2021-27384" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" }, { "trust": 1.6, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "trust": 1.6, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "trust": 1.2, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu91051134/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-27384" }, { "trust": 0.8, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-131-11" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021051206" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/smartvnc-multiple-vulnerabilities-35360" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/788.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://cert-portal.siemens.com/productcert/txt/ssa-286838.txt" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37750" }, { "db": "VULMON", "id": "CVE-2021-27384" }, { "db": "JVNDB", "id": "JVNDB-2021-006949" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-548" }, { "db": "NVD", "id": "CVE-2021-27384" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-37750" }, { "db": "VULMON", "id": "CVE-2021-27384" }, { "db": "JVNDB", "id": "JVNDB-2021-006949" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-548" }, { "db": "NVD", "id": "CVE-2021-27384" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-05-28T00:00:00", "db": "CNVD", "id": "CNVD-2021-37750" }, { "date": "2021-05-12T00:00:00", "db": "VULMON", "id": "CVE-2021-27384" }, { "date": "2022-01-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-006949" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-05-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-548" }, { "date": "2021-05-12T14:15:11.677000", "db": "NVD", "id": "CVE-2021-27384" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-05-28T00:00:00", "db": "CNVD", "id": "CNVD-2021-37750" }, { "date": "2021-05-21T00:00:00", "db": "VULMON", "id": "CVE-2021-27384" }, { "date": "2022-01-26T07:30:00", "db": "JVNDB", "id": "JVNDB-2021-006949" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-10-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-548" }, { "date": "2021-12-16T18:26:10.080000", "db": "NVD", "id": "CVE-2021-27384" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-548" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Vulnerabilities in access to memory areas after buffer termination in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006949" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-548" } ], "trust": 1.2 } }
var-201202-0044
Vulnerability from variot
The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account, which makes it easier for remote attackers to obtain access via a brute-force approach involving many HTTP requests. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. The default management password exists for multiple Siemens SIMATIC products. The default account password for the WEB interface is \"Administrator: 100\", and the password \"100\" can also be used for the VNC service. If the user changes the password containing special characters, the system will put the password. Reset to \"100\". The following products are affected by this vulnerability: SIMATIC WinCC Flexible 2004 through 2008 SP2SIMATIC WinCC V11, V11 SP1, and V11 SP2 SIMATIC HMI TP, OP, MP, Mobile, and Comfort Series Panels Successful exploits allow an attacker to log in with user or administrator privileges Affect the system. An attacker can exploit these issues to bypass intended security restrictions and gain access to the affected application. Successfully exploiting these issues may lead to further attacks. The Siemens SIMATIC HMI product family is used as the human-machine interface between the corresponding PLC and the operator
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0044", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "mp" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "op" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "tp" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2007" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2005" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2004" }, { "model": "simatic wincc", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "v11" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "2008" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "comfort_panels" }, { "model": "wincc runtime advanced", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "v11" }, { "model": "wincc", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "v11" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "mobile_panels" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "2007" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2004" }, { "model": "wincc flexible runtime", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2005" }, { "model": "simatic wincc flexible sp1", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc flexible sp2", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc flexible sp1", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "2005" }, { "model": "simatic wincc flexible runtime", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc sp2", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "v11" }, { "model": "simatic wincc sp1", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "v11" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "comfort panels" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "mobile panels" }, { "model": "simatic wincc flexible rumtime", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "v11" }, { "model": "wincc flexible runtime", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2004" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2005" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2007" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2008" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc", "version": "v11" }, { "model": "comfort panels", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "mobile panels", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "mp", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "op", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "tp", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc runtime advanced", "version": "v11" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible runtime", "version": "*" } ], "sources": [ { "db": "IVD", "id": "2875d28a-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5449" }, { "db": "BID", "id": "51177" }, { "db": "JVNDB", "id": "JVNDB-2012-001311" }, { "db": "CNNVD", "id": "CNNVD-201112-423" }, { "db": "NVD", "id": "CVE-2011-4509" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:siemens:simatic_hmi_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_flexible", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_flexible_runtime", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2012-001311" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Billy Rios and Terry McCorkle", "sources": [ { "db": "BID", "id": "51177" }, { "db": "CNNVD", "id": "CNNVD-201112-423" } ], "trust": 0.9 }, "cve": "CVE-2011-4509", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CVE-2011-4509", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "2875d28a-2354-11e6-abef-000c29c66e3d", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "VHN-52454", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2011-4509", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2011-4509", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-201112-423", "trust": 0.6, "value": "CRITICAL" }, { "author": "IVD", "id": "2875d28a-2354-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "CRITICAL" }, { "author": "VULHUB", "id": "VHN-52454", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "IVD", "id": "2875d28a-2354-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-52454" }, { "db": "JVNDB", "id": "JVNDB-2012-001311" }, { "db": "CNNVD", "id": "CNNVD-201112-423" }, { "db": "NVD", "id": "CVE-2011-4509" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account, which makes it easier for remote attackers to obtain access via a brute-force approach involving many HTTP requests. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. The default management password exists for multiple Siemens SIMATIC products. The default account password for the WEB interface is \\\"Administrator: 100\\\", and the password \\\"100\\\" can also be used for the VNC service. If the user changes the password containing special characters, the system will put the password. Reset to \\\"100\\\". The following products are affected by this vulnerability: SIMATIC WinCC Flexible 2004 through 2008 SP2SIMATIC WinCC V11, V11 SP1, and V11 SP2 SIMATIC HMI TP, OP, MP, Mobile, and Comfort Series Panels Successful exploits allow an attacker to log in with user or administrator privileges Affect the system. \nAn attacker can exploit these issues to bypass intended security restrictions and gain access to the affected application. Successfully exploiting these issues may lead to further attacks. The Siemens SIMATIC HMI product family is used as the human-machine interface between the corresponding PLC and the operator", "sources": [ { "db": "NVD", "id": "CVE-2011-4509" }, { "db": "JVNDB", "id": "JVNDB-2012-001311" }, { "db": "CNVD", "id": "CNVD-2011-5449" }, { "db": "BID", "id": "51177" }, { "db": "IVD", "id": "2875d28a-2354-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-52454" } ], "trust": 2.7 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2011-4509", "trust": 3.6 }, { "db": "ICS CERT", "id": "ICSA-12-030-01", "trust": 2.5 }, { "db": "SIEMENS", "id": "SSA-345442", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-201112-423", "trust": 0.9 }, { "db": "BID", "id": "51177", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2011-5449", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2012-001311", "trust": 0.8 }, { "db": "NSFOCUS", "id": "18390", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-11-356-01", "trust": 0.3 }, { "db": "ICS CERT", "id": "ICSA-12-030-01A", "trust": 0.3 }, { "db": "IVD", "id": "2875D28A-2354-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-52454", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "2875d28a-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5449" }, { "db": "VULHUB", "id": "VHN-52454" }, { "db": "BID", "id": "51177" }, { "db": "JVNDB", "id": "JVNDB-2012-001311" }, { "db": "CNNVD", "id": "CNNVD-201112-423" }, { "db": "NVD", "id": "CVE-2011-4509" } ] }, "id": "VAR-201202-0044", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "2875d28a-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5449" }, { "db": "VULHUB", "id": "VHN-52454" } ], "trust": 1.575178075 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "2875d28a-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5449" } ] }, "last_update_date": "2024-11-23T21:46:29.700000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-345442", "trust": 0.8, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "title": "\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc", "trust": 0.8, "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx" }, { "title": "Top Page", "trust": 0.8, "url": "http://www.siemens.com/entry/jp/ja/" }, { "title": "Patch for multiple Siemens SIMATIC Product Verification Bypass Vulnerabilities (CNVD-2011-5449)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/72709" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2011-5449" }, { "db": "JVNDB", "id": "JVNDB-2012-001311" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-264", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-52454" }, { "db": "JVNDB", "id": "JVNDB-2012-001311" }, { "db": "NVD", "id": "CVE-2011-4509" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01.pdf" }, { "trust": 1.7, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4509" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4509" }, { "trust": 0.6, "url": "http://xs-sniper.com/blog/2011/12/20/the-siemens-simatic-remote-authentication-bypass-that-doesnt-exist/http" }, { "trust": 0.6, "url": "http://www.securityfocus.com/bid/51177" }, { "trust": 0.6, "url": "http://www.nsfocus.net/vulndb/18390" }, { "trust": 0.3, "url": "http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/pages/default.aspx" }, { "trust": 0.3, "url": "http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/wincc-flexible/wincc-flexible-runtime/user-interface/pages/default.aspx" }, { "trust": 0.3, "url": "http://xs-sniper.com/blog/2011/12/20/the-siemens-simatic-remote-authentication-bypass-that-doesnt-exist/" }, { "trust": 0.3, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01a.pdf" }, { "trust": 0.3, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-11-356-01.pdf" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2011-5449" }, { "db": "VULHUB", "id": "VHN-52454" }, { "db": "BID", "id": "51177" }, { "db": "JVNDB", "id": "JVNDB-2012-001311" }, { "db": "CNNVD", "id": "CNNVD-201112-423" }, { "db": "NVD", "id": "CVE-2011-4509" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "2875d28a-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5449" }, { "db": "VULHUB", "id": "VHN-52454" }, { "db": "BID", "id": "51177" }, { "db": "JVNDB", "id": "JVNDB-2012-001311" }, { "db": "CNNVD", "id": "CNNVD-201112-423" }, { "db": "NVD", "id": "CVE-2011-4509" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2011-12-26T00:00:00", "db": "IVD", "id": "2875d28a-2354-11e6-abef-000c29c66e3d" }, { "date": "2011-12-26T00:00:00", "db": "CNVD", "id": "CNVD-2011-5449" }, { "date": "2012-02-03T00:00:00", "db": "VULHUB", "id": "VHN-52454" }, { "date": "2011-12-22T00:00:00", "db": "BID", "id": "51177" }, { "date": "2012-02-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001311" }, { "date": "1900-01-01T00:00:00", "db": "CNNVD", "id": "CNNVD-201112-423" }, { "date": "2012-02-03T20:55:01.297000", "db": "NVD", "id": "CVE-2011-4509" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2016-03-15T00:00:00", "db": "CNVD", "id": "CNVD-2011-5449" }, { "date": "2012-02-06T00:00:00", "db": "VULHUB", "id": "VHN-52454" }, { "date": "2012-04-18T21:20:00", "db": "BID", "id": "51177" }, { "date": "2012-02-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001311" }, { "date": "2011-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-201112-423" }, { "date": "2024-11-21T01:32:26.890000", "db": "NVD", "id": "CVE-2011-4509" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201112-423" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Siemens Product HMI Web Vulnerability to gain access rights on the server", "sources": [ { "db": "JVNDB", "id": "JVNDB-2012-001311" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "permissions and access control", "sources": [ { "db": "CNNVD", "id": "CNNVD-201112-423" } ], "trust": 0.6 } }
var-201812-0343
Vulnerability from variot
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known. plural SIMATIC The product contains a path traversal vulnerability.Information may be obtained. Siemens SIMATIC Panels is prone to following security vulnerabilities: 1. An open-redirection vulnerability 2. A directory-traversal vulnerability Remote attackers may use a specially crafted request with directory-traversal sequences ('../') to retrieve arbitrary files from the affected system in the context of the application or by constructing a crafted URI and enticing a user to follow it and when an unsuspecting victim follows the link, they may be redirected to an attacker-controlled site. are all HMI software used by Siemens in Germany to control and monitor machines and equipment
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201812-0343", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic wincc runtime", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "15.0" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "15.0" }, { "model": "simatic hmi mp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi op", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort panels", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "15.0" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "15.0" }, { "model": "simatic hmi comfort outdoor panels", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "15.0" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "15.0" }, { "model": "simatic wincc \\", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "15.0" }, { "model": "simatic hmi tp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "15.0" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "15.0" }, { "model": "simatic hmi comfort outdoor panels", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi comfort panels", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime professional", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15" }, { "model": "simatic wincc runtime professional sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "14" }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "14" }, { "model": "simatic wincc runtime professional sp2", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "13" }, { "model": "simatic wincc runtime professional sp1 upd2", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "13" }, { "model": "simatic wincc runtime professional sp update", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1319" }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "13" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15" }, { "model": "simatic wincc runtime advanced sp1 upd2", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "13" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "13" }, { "model": "simatic wincc runtime advanced sp1 upd5", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "12" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "12" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc update", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v135" }, { "model": "simatic wincc sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v12" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v120" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v110" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v15" }, { "model": "simatic wincc update", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v136" }, { "model": "simatic wincc sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v13" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v13" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v10" }, { "model": "simatic hmi ktp mobile panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "22" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15" }, { "model": "simatic hmi comfort panels sp1 upd2", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "13" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "13" }, { "model": "simatic hmi comfort panels sp1 upd5", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "12" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "12" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi comfort outdoor panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi classic devices", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc runtime professional update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "154" }, { "model": "simatic wincc runtime advanced update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "154" }, { "model": "simatic wincc update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "154" }, { "model": "simatic hmi ktp mobile panels update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "154" }, { "model": "simatic hmi comfort panels update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "154" }, { "model": "simatic hmi comfort outdoor panels update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "154" } ], "sources": [ { "db": "BID", "id": "105922" }, { "db": "JVNDB", "id": "JVNDB-2018-014525" }, { "db": "NVD", "id": "CVE-2018-13812" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_outdoor_panels_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_runtime_professional", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-014525" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Hosni Tounsi from Carthage Red Team", "sources": [ { "db": "BID", "id": "105922" } ], "trust": 0.3 }, "cve": "CVE-2018-13812", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2018-13812", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "VHN-123909", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2018-13812", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-13812", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2018-13812", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-201811-482", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-123909", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-123909" }, { "db": "JVNDB", "id": "JVNDB-2018-014525" }, { "db": "CNNVD", "id": "CNNVD-201811-482" }, { "db": "NVD", "id": "CVE-2018-13812" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions \u003c V15 Update 4), SIMATIC WinCC Runtime Professional (All versions \u003c V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions \u003c V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known. plural SIMATIC The product contains a path traversal vulnerability.Information may be obtained. Siemens SIMATIC Panels is prone to following security vulnerabilities:\n1. An open-redirection vulnerability\n2. A directory-traversal vulnerability\nRemote attackers may use a specially crafted request with directory-traversal sequences (\u0027../\u0027) to retrieve arbitrary files from the affected system in the context of the application or by constructing a crafted URI and enticing a user to follow it and when an unsuspecting victim follows the link, they may be redirected to an attacker-controlled site. are all HMI software used by Siemens in Germany to control and monitor machines and equipment", "sources": [ { "db": "NVD", "id": "CVE-2018-13812" }, { "db": "JVNDB", "id": "JVNDB-2018-014525" }, { "db": "BID", "id": "105922" }, { "db": "VULHUB", "id": "VHN-123909" } ], "trust": 1.98 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-13812", "trust": 2.8 }, { "db": "BID", "id": "105922", "trust": 2.0 }, { "db": "SIEMENS", "id": "SSA-233109", "trust": 1.7 }, { "db": "ICS CERT", "id": "ICSA-18-317-08", "trust": 1.7 }, { "db": "JVNDB", "id": "JVNDB-2018-014525", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201811-482", "trust": 0.7 }, { "db": "VULHUB", "id": "VHN-123909", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-123909" }, { "db": "BID", "id": "105922" }, { "db": "JVNDB", "id": "JVNDB-2018-014525" }, { "db": "CNNVD", "id": "CNNVD-201811-482" }, { "db": "NVD", "id": "CVE-2018-13812" } ] }, "id": "VAR-201812-0343", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-123909" } ], "trust": 0.7828699085714284 }, "last_update_date": "2024-11-23T22:17:14.886000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-233109", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf" }, { "title": "Multiple Siemens Product path traversal vulnerability fixes", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=86883" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-014525" }, { "db": "CNNVD", "id": "CNNVD-201811-482" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-22", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-123909" }, { "db": "JVNDB", "id": "JVNDB-2018-014525" }, { "db": "NVD", "id": "CVE-2018-13812" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "http://www.securityfocus.com/bid/105922" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf" }, { "trust": 1.7, "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-317-08" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-13812" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-13812" }, { "trust": 0.3, "url": "http://subscriber.communications.siemens.com/" } ], "sources": [ { "db": "VULHUB", "id": "VHN-123909" }, { "db": "BID", "id": "105922" }, { "db": "JVNDB", "id": "JVNDB-2018-014525" }, { "db": "CNNVD", "id": "CNNVD-201811-482" }, { "db": "NVD", "id": "CVE-2018-13812" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-123909" }, { "db": "BID", "id": "105922" }, { "db": "JVNDB", "id": "JVNDB-2018-014525" }, { "db": "CNNVD", "id": "CNNVD-201811-482" }, { "db": "NVD", "id": "CVE-2018-13812" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-12-13T00:00:00", "db": "VULHUB", "id": "VHN-123909" }, { "date": "2018-11-14T00:00:00", "db": "BID", "id": "105922" }, { "date": "2019-03-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-014525" }, { "date": "2018-11-15T00:00:00", "db": "CNNVD", "id": "CNNVD-201811-482" }, { "date": "2018-12-13T16:29:00.290000", "db": "NVD", "id": "CVE-2018-13812" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-10-09T00:00:00", "db": "VULHUB", "id": "VHN-123909" }, { "date": "2018-11-14T00:00:00", "db": "BID", "id": "105922" }, { "date": "2019-03-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-014525" }, { "date": "2019-10-17T00:00:00", "db": "CNNVD", "id": "CNNVD-201811-482" }, { "date": "2024-11-21T03:48:07.190000", "db": "NVD", "id": "CVE-2018-13812" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201811-482" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural SIMATIC Path traversal vulnerability in products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-014525" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "path traversal", "sources": [ { "db": "CNNVD", "id": "CNNVD-201811-482" } ], "trust": 0.6 } }
var-201109-0223
Vulnerability from variot
Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308. Siemens SIMATIC WinCC flexible and WinCC (TIA Portal) Runtime Advanced is a software package for virtualization. A security vulnerability exists in the implementation of Siemens SIMATIC WinCC, which can be exploited by malicious users to control the affected system. This vulnerability stems from an error in the runtime loader when parsing a received message, causing a heap buffer overflow through a specially crafted message sent to port 2308/TCP. ----------------------------------------------------------------------
The new Secunia Corporate Software Inspector (CSI) 5.0 Integrates with Microsoft WSUS & SCCM and supports Apple Mac OS X.
Get a free trial now and qualify for a special discount: http://secunia.com/vulnerability_scanning/corporate/trial/
TITLE: Siemens SIMATIC WinCC Runtime Loader Buffer Overflow Vulnerability
SECUNIA ADVISORY ID: SA46011
VERIFY ADVISORY: Secunia.com http://secunia.com/advisories/46011/ Customer Area (Credentials Required) https://ca.secunia.com/?page=viewadvisory&vuln_id=46011
RELEASE DATE: 2011-09-15
DISCUSS ADVISORY: http://secunia.com/advisories/46011/#comments
AVAILABLE ON SITE AND IN CUSTOMER AREA: * Last Update * Popularity * Comments * Criticality Level * Impact * Where * Solution Status * Operating System / Software * CVE Reference(s)
http://secunia.com/advisories/46011/
ONLY AVAILABLE IN CUSTOMER AREA: * Authentication Level * Report Reliability * Secunia PoC * Secunia Analysis * Systems Affected * Approve Distribution * Remediation Status * Secunia CVSS Score * CVSS
https://ca.secunia.com/?page=viewadvisory&vuln_id=46011
ONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI: * AUTOMATED SCANNING
http://secunia.com/vulnerability_scanning/personal/ http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/
DESCRIPTION: A vulnerability has been reported in Siemens SIMATIC WinCC, which can be exploited by malicious people to potentially compromise a vulnerable system.
Successful exploitation may allow execution of arbitrary code, but requires that "transfer" mode is enabled (disabled by default).
SOLUTION: Disable "transfer" mode or restrict access to port 2308/TCP.
PROVIDED AND/OR DISCOVERED BY: Billy Rios and Terry McCorkle via ICS-CERT.
ORIGINAL ADVISORY: Siemens: http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=de&objid=29054992&caller=view http://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf
ICS-CERT: http://www.us-cert.gov/control_systems/pdf/ICSA-11-244-01.pdf
OTHER REFERENCES: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
DEEP LINKS: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED DESCRIPTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED SOLUTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXPLOIT: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
About: This Advisory was delivered by Secunia as a free service to help private users keeping their systems up to date against the latest vulnerabilities.
Subscribe: http://secunia.com/advisories/secunia_security_advisories/
Definitions: (Criticality, Where etc.) http://secunia.com/advisories/about_secunia_advisories/
Please Note: Secunia recommends that you verify all advisories you receive by clicking the link. Secunia NEVER sends attached files with advisories. Secunia does not advise people to install third party patches, only use those supplied by the vendor.
Unsubscribe: Secunia Security Advisories http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org
Show details on source website
{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201109-0223", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic wincc runtime", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc flexible runtime", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic wincc flexible rumtime", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": null, "scope": null, "trust": 0.6, "vendor": "no", "version": null }, { "model": "simatic wincc flexible runtime", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "simatic wincc flexible runtime", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "simatic wincc runtime", "version": null } ], "sources": [ { "db": "IVD", "id": "7d7d7a11-463f-11e9-84c1-000c29342cb1" }, { "db": "IVD", "id": "a57fd672-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-6876" }, { "db": "JVNDB", "id": "JVNDB-2011-002270" }, { "db": "CNNVD", "id": "CNNVD-201109-224" }, { "db": "NVD", "id": "CVE-2011-3321" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:siemens:wincc_flexible_runtime", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2011-002270" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Secunia", "sources": [ { "db": "PACKETSTORM", "id": "105133" } ], "trust": 0.1 }, "cve": "CVE-2011-3321", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.6, "id": "CVE-2011-3321", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.6, "id": "CNVD-2011-6876", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.6, "id": "7d7d7a11-463f-11e9-84c1-000c29342cb1", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.6, "id": "a57fd672-2354-11e6-abef-000c29c66e3d", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.6, "id": "VHN-51266", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:M/AU:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2011-3321", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2011-3321", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2011-6876", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201109-224", "trust": 0.6, "value": "CRITICAL" }, { "author": "IVD", "id": "7d7d7a11-463f-11e9-84c1-000c29342cb1", "trust": 0.2, "value": "CRITICAL" }, { "author": "IVD", "id": "a57fd672-2354-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "CRITICAL" }, { "author": "VULHUB", "id": "VHN-51266", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "IVD", "id": "7d7d7a11-463f-11e9-84c1-000c29342cb1" }, { "db": "IVD", "id": "a57fd672-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-6876" }, { "db": "VULHUB", "id": "VHN-51266" }, { "db": "JVNDB", "id": "JVNDB-2011-002270" }, { "db": "CNNVD", "id": "CNNVD-201109-224" }, { "db": "NVD", "id": "CVE-2011-3321" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308. Siemens SIMATIC WinCC flexible and WinCC (TIA Portal) Runtime Advanced is a software package for virtualization. A security vulnerability exists in the implementation of Siemens SIMATIC WinCC, which can be exploited by malicious users to control the affected system. This vulnerability stems from an error in the runtime loader when parsing a received message, causing a heap buffer overflow through a specially crafted message sent to port 2308/TCP. ----------------------------------------------------------------------\n\nThe new Secunia Corporate Software Inspector (CSI) 5.0 \nIntegrates with Microsoft WSUS \u0026 SCCM and supports Apple Mac OS X. \n\nGet a free trial now and qualify for a special discount:\nhttp://secunia.com/vulnerability_scanning/corporate/trial/\n\n----------------------------------------------------------------------\n\nTITLE:\nSiemens SIMATIC WinCC Runtime Loader Buffer Overflow Vulnerability\n\nSECUNIA ADVISORY ID:\nSA46011\n\nVERIFY ADVISORY:\nSecunia.com\nhttp://secunia.com/advisories/46011/\nCustomer Area (Credentials Required)\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=46011\n\nRELEASE DATE:\n2011-09-15\n\nDISCUSS ADVISORY:\nhttp://secunia.com/advisories/46011/#comments\n\nAVAILABLE ON SITE AND IN CUSTOMER AREA:\n * Last Update\n * Popularity\n * Comments\n * Criticality Level\n * Impact\n * Where\n * Solution Status\n * Operating System / Software\n * CVE Reference(s)\n\nhttp://secunia.com/advisories/46011/\n\nONLY AVAILABLE IN CUSTOMER AREA:\n * Authentication Level\n * Report Reliability\n * Secunia PoC\n * Secunia Analysis\n * Systems Affected\n * Approve Distribution\n * Remediation Status\n * Secunia CVSS Score\n * CVSS\n\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=46011\n\nONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI:\n * AUTOMATED SCANNING\n\nhttp://secunia.com/vulnerability_scanning/personal/\nhttp://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/\n\nDESCRIPTION:\nA vulnerability has been reported in Siemens SIMATIC WinCC, which can\nbe exploited by malicious people to potentially compromise a\nvulnerable system. \n\nSuccessful exploitation may allow execution of arbitrary code, but\nrequires that \"transfer\" mode is enabled (disabled by default). \n\nSOLUTION:\nDisable \"transfer\" mode or restrict access to port 2308/TCP. \n\nPROVIDED AND/OR DISCOVERED BY:\nBilly Rios and Terry McCorkle via ICS-CERT. \n\nORIGINAL ADVISORY:\nSiemens:\nhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo\u0026lang=de\u0026objid=29054992\u0026caller=view\nhttp://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf\n\nICS-CERT:\nhttp://www.us-cert.gov/control_systems/pdf/ICSA-11-244-01.pdf\n\nOTHER REFERENCES:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nDEEP LINKS:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED DESCRIPTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED SOLUTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXPLOIT:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\n----------------------------------------------------------------------\n\nAbout:\nThis Advisory was delivered by Secunia as a free service to help\nprivate users keeping their systems up to date against the latest\nvulnerabilities. \n\nSubscribe:\nhttp://secunia.com/advisories/secunia_security_advisories/\n\nDefinitions: (Criticality, Where etc.)\nhttp://secunia.com/advisories/about_secunia_advisories/\n\n\nPlease Note:\nSecunia recommends that you verify all advisories you receive by\nclicking the link. \nSecunia NEVER sends attached files with advisories. \nSecunia does not advise people to install third party patches, only\nuse those supplied by the vendor. \n\n----------------------------------------------------------------------\n\nUnsubscribe: Secunia Security Advisories\nhttp://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org\n\n----------------------------------------------------------------------\n\n\n", "sources": [ { "db": "NVD", "id": "CVE-2011-3321" }, { "db": "JVNDB", "id": "JVNDB-2011-002270" }, { "db": "CNVD", "id": "CNVD-2011-6876" }, { "db": "IVD", "id": "7d7d7a11-463f-11e9-84c1-000c29342cb1" }, { "db": "IVD", "id": "a57fd672-2354-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-51266" }, { "db": "PACKETSTORM", "id": "105133" } ], "trust": 2.7 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2011-3321", "trust": 3.5 }, { "db": "ICS CERT", "id": "ICSA-11-244-01", "trust": 2.6 }, { "db": "SECUNIA", "id": "46011", "trust": 2.0 }, { "db": "SIEMENS", "id": "SSA-460621", "trust": 1.8 }, { "db": "CNVD", "id": "CNVD-2011-6876", "trust": 1.0 }, { "db": "CNNVD", "id": "CNNVD-201109-224", "trust": 1.0 }, { "db": "JVNDB", "id": "JVNDB-2011-002270", "trust": 0.8 }, { "db": "NSFOCUS", "id": "17733", "trust": 0.6 }, { "db": "IVD", "id": "7D7D7A11-463F-11E9-84C1-000C29342CB1", "trust": 0.2 }, { "db": "IVD", "id": "A57FD672-2354-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-51266", "trust": 0.1 }, { "db": "PACKETSTORM", "id": "105133", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "7d7d7a11-463f-11e9-84c1-000c29342cb1" }, { "db": "IVD", "id": "a57fd672-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-6876" }, { "db": "VULHUB", "id": "VHN-51266" }, { "db": "JVNDB", "id": "JVNDB-2011-002270" }, { "db": "PACKETSTORM", "id": "105133" }, { "db": "CNNVD", "id": "CNNVD-201109-224" }, { "db": "NVD", "id": "CVE-2011-3321" } ] }, "id": "VAR-201109-0223", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "7d7d7a11-463f-11e9-84c1-000c29342cb1" }, { "db": "IVD", "id": "a57fd672-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-6876" }, { "db": "VULHUB", "id": "VHN-51266" } ], "trust": 1.7353303000000002 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 1.0 } ], "sources": [ { "db": "IVD", "id": "7d7d7a11-463f-11e9-84c1-000c29342cb1" }, { "db": "IVD", "id": "a57fd672-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-6876" } ] }, "last_update_date": "2024-11-23T22:56:49.738000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SIEMENS-SSA-460621", "trust": 0.8, "url": "http://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf" }, { "title": "\u30b7\u30fc\u30e1\u30f3\u30b9\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc ", "trust": 0.8, "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx" }, { "title": "\u30b7\u30fc\u30e1\u30f3\u30b9\u30fb\u30b8\u30e3\u30d1\u30f3\u682a\u5f0f\u4f1a\u793e", "trust": 0.8, "url": "http://www.siemens.com/entry/jp/ja/" }, { "title": "Patch for the Siemens SIMATIC WinCC Runtime Loader Buffer Overflow Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/43377" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2011-6876" }, { "db": "JVNDB", "id": "JVNDB-2011-002270" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-119", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-51266" }, { "db": "JVNDB", "id": "JVNDB-2011-002270" }, { "db": "NVD", "id": "CVE-2011-3321" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.6, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-11-244-01.pdf" }, { "trust": 1.7, "url": "http://support.automation.siemens.com/ww/view/en/29054992" }, { "trust": 1.7, "url": "http://secunia.com/advisories/46011" }, { "trust": 1.2, "url": "http://cache.automation.siemens.com/dnl/ji/ji0ndy5aaaa_29054992_faq/siemens_security_advisory_ssa-460621_v1_2.pdf" }, { "trust": 1.1, "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69803" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-3321" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-3321" }, { "trust": 0.6, "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-460621.pdf" }, { "trust": 0.6, "url": "http://www.nsfocus.net/vulndb/17733" }, { "trust": 0.1, "url": "http://secunia.com/vulnerability_scanning/corporate/trial/" }, { "trust": 0.1, "url": "http://secunia.com/vulnerability_intelligence/" }, { "trust": 0.1, "url": "http://secunia.com/advisories/secunia_security_advisories/" }, { "trust": 0.1, "url": "http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/" }, { "trust": 0.1, "url": "http://secunia.com/advisories/about_secunia_advisories/" }, { "trust": 0.1, "url": "http://secunia.com/vulnerability_scanning/personal/" }, { "trust": 0.1, "url": "http://secunia.com/advisories/46011/#comments" }, { "trust": 0.1, "url": "http://support.automation.siemens.com/ww/llisapi.dll?func=cslib.csinfo\u0026lang=de\u0026objid=29054992\u0026caller=view" }, { "trust": 0.1, "url": "http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org" }, { "trust": 0.1, "url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=46011" }, { "trust": 0.1, "url": "http://secunia.com/advisories/46011/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2011-6876" }, { "db": "VULHUB", "id": "VHN-51266" }, { "db": "JVNDB", "id": "JVNDB-2011-002270" }, { "db": "PACKETSTORM", "id": "105133" }, { "db": "CNNVD", "id": "CNNVD-201109-224" }, { "db": "NVD", "id": "CVE-2011-3321" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "7d7d7a11-463f-11e9-84c1-000c29342cb1" }, { "db": "IVD", "id": "a57fd672-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-6876" }, { "db": "VULHUB", "id": "VHN-51266" }, { "db": "JVNDB", "id": "JVNDB-2011-002270" }, { "db": "PACKETSTORM", "id": "105133" }, { "db": "CNNVD", "id": "CNNVD-201109-224" }, { "db": "NVD", "id": "CVE-2011-3321" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2014-02-18T00:00:00", "db": "IVD", "id": "7d7d7a11-463f-11e9-84c1-000c29342cb1" }, { "date": "2014-02-18T00:00:00", "db": "IVD", "id": "a57fd672-2354-11e6-abef-000c29c66e3d" }, { "date": "2011-09-14T00:00:00", "db": "CNVD", "id": "CNVD-2011-6876" }, { "date": "2011-09-16T00:00:00", "db": "VULHUB", "id": "VHN-51266" }, { "date": "2011-09-29T00:00:00", "db": "JVNDB", "id": "JVNDB-2011-002270" }, { "date": "2011-09-15T06:46:52", "db": "PACKETSTORM", "id": "105133" }, { "date": "2011-09-16T00:00:00", "db": "CNNVD", "id": "CNNVD-201109-224" }, { "date": "2011-09-16T12:35:26.450000", "db": "NVD", "id": "CVE-2011-3321" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2016-09-13T00:00:00", "db": "CNVD", "id": "CNVD-2011-6876" }, { "date": "2017-08-29T00:00:00", "db": "VULHUB", "id": "VHN-51266" }, { "date": "2011-09-29T00:00:00", "db": "JVNDB", "id": "JVNDB-2011-002270" }, { "date": "2011-09-20T00:00:00", "db": "CNNVD", "id": "CNNVD-201109-224" }, { "date": "2024-11-21T01:30:15.513000", "db": "NVD", "id": "CVE-2011-3321" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201109-224" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens SIMATIC WinCC Runtime Loader Buffer Overflow Vulnerability", "sources": [ { "db": "IVD", "id": "7d7d7a11-463f-11e9-84c1-000c29342cb1" }, { "db": "IVD", "id": "a57fd672-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-6876" }, { "db": "CNNVD", "id": "CNNVD-201109-224" } ], "trust": 1.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Buffer overflow", "sources": [ { "db": "IVD", "id": "7d7d7a11-463f-11e9-84c1-000c29342cb1" }, { "db": "IVD", "id": "a57fd672-2354-11e6-abef-000c29c66e3d" }, { "db": "CNNVD", "id": "CNNVD-201109-224" } ], "trust": 1.0 } }
var-201202-0043
Vulnerability from variot
The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie. plural Siemens Product HMI Web The server Cookie There is a vulnerability that prevents authentication because it generates a predictable authentication token.Skillfully crafted by a third party Cookie Authentication may be bypassed. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. Multiple Siemens SIMATIC products have security vulnerabilities, and the insecure generation of authentication tokens (session COOKIE guesses) allows an attacker to bypass authentication checks and increase privileges without a username and password. An attacker can exploit these issues to bypass intended security restrictions and gain access to the affected application. Successfully exploiting these issues may lead to further attacks. The Siemens SIMATIC HMI product family is used as the human-machine interface between the corresponding PLC and the operator
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0043", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "mp" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "op" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "tp" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2007" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2005" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2004" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "comfort_panels" }, { "model": "wincc runtime advanced", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "v11" }, { "model": "wincc", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "v11" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "mobile_panels" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2004" }, { "model": "wincc flexible runtime", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2007" }, { "model": "wincc", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "v11" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2005" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc flexible sp1", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc flexible sp2", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc flexible sp1", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "2005" }, { "model": "simatic wincc flexible runtime", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc sp2", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "v11" }, { "model": "simatic wincc sp1", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "v11" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "v11" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "comfort panels" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "mobile panels" }, { "model": "simatic wincc", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "v11 sp2 update 1" }, { "model": "simatic wincc flexible", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "2008 sp3" }, { "model": "simatic wincc flexible rumtime", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "v11" }, { "model": null, "scope": "eq", "trust": 0.6, "vendor": "wincc flexible", "version": "2008" }, { "model": "wincc flexible runtime", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "wincc", "version": "v11" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2004" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2005" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2007" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc", "version": "*" }, { "model": "comfort panels", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "mobile panels", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "mp", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "op", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "tp", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc runtime advanced", "version": "v11" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible runtime", "version": "*" } ], "sources": [ { "db": "IVD", "id": "28828750-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5448" }, { "db": "BID", "id": "51177" }, { "db": "JVNDB", "id": "JVNDB-2012-001310" }, { "db": "CNNVD", "id": "CNNVD-201112-422" }, { "db": "NVD", "id": "CVE-2011-4508" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:siemens:simatic_hmi_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_flexible", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_flexible_runtime", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2012-001310" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Billy Rios and Terry McCorkle", "sources": [ { "db": "BID", "id": "51177" }, { "db": "CNNVD", "id": "CNNVD-201112-422" } ], "trust": 0.9 }, "cve": "CVE-2011-4508", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.6, "id": "CVE-2011-4508", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.0, "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 10.0, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2011-4508", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.6, "id": "28828750-2354-11e6-abef-000c29c66e3d", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.6, "id": "VHN-52453", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:M/AU:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2011-4508", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2011-4508", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-201112-422", "trust": 0.6, "value": "CRITICAL" }, { "author": "IVD", "id": "28828750-2354-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "CRITICAL" }, { "author": "VULHUB", "id": "VHN-52453", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "IVD", "id": "28828750-2354-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-52453" }, { "db": "JVNDB", "id": "JVNDB-2012-001310" }, { "db": "CNNVD", "id": "CNNVD-201112-422" }, { "db": "NVD", "id": "CVE-2011-4508" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie. plural Siemens Product HMI Web The server Cookie There is a vulnerability that prevents authentication because it generates a predictable authentication token.Skillfully crafted by a third party Cookie Authentication may be bypassed. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. Multiple Siemens SIMATIC products have security vulnerabilities, and the insecure generation of authentication tokens (session COOKIE guesses) allows an attacker to bypass authentication checks and increase privileges without a username and password. \nAn attacker can exploit these issues to bypass intended security restrictions and gain access to the affected application. Successfully exploiting these issues may lead to further attacks. The Siemens SIMATIC HMI product family is used as the human-machine interface between the corresponding PLC and the operator", "sources": [ { "db": "NVD", "id": "CVE-2011-4508" }, { "db": "JVNDB", "id": "JVNDB-2012-001310" }, { "db": "CNVD", "id": "CNVD-2011-5448" }, { "db": "BID", "id": "51177" }, { "db": "IVD", "id": "28828750-2354-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-52453" } ], "trust": 2.7 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2011-4508", "trust": 3.6 }, { "db": "ICS CERT", "id": "ICSA-12-030-01", "trust": 2.5 }, { "db": "SIEMENS", "id": "SSA-345442", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-201112-422", "trust": 0.9 }, { "db": "BID", "id": "51177", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2011-5448", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2012-001310", "trust": 0.8 }, { "db": "NSFOCUS", "id": "18390", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-11-356-01", "trust": 0.3 }, { "db": "ICS CERT", "id": "ICSA-12-030-01A", "trust": 0.3 }, { "db": "IVD", "id": "28828750-2354-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-52453", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "28828750-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5448" }, { "db": "VULHUB", "id": "VHN-52453" }, { "db": "BID", "id": "51177" }, { "db": "JVNDB", "id": "JVNDB-2012-001310" }, { "db": "CNNVD", "id": "CNNVD-201112-422" }, { "db": "NVD", "id": "CVE-2011-4508" } ] }, "id": "VAR-201202-0043", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "28828750-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5448" }, { "db": "VULHUB", "id": "VHN-52453" } ], "trust": 1.575178075 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "28828750-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5448" } ] }, "last_update_date": "2024-11-23T21:46:29.776000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-345442", "trust": 0.8, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "title": "\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc", "trust": 0.8, "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx" }, { "title": "Top Page", "trust": 0.8, "url": "http://www.siemens.com/entry/jp/ja/" }, { "title": "Patch for multiple Siemens SIMATIC Product Verification Bypass Vulnerabilities (CNVD-2011-5448)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/72707" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2011-5448" }, { "db": "JVNDB", "id": "JVNDB-2012-001310" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-287", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-52453" }, { "db": "JVNDB", "id": "JVNDB-2012-001310" }, { "db": "NVD", "id": "CVE-2011-4508" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01.pdf" }, { "trust": 1.7, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4508" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4508" }, { "trust": 0.6, "url": "http://xs-sniper.com/blog/2011/12/20/the-siemens-simatic-remote-authentication-bypass-that-doesnt-exist/http" }, { "trust": 0.6, "url": "http://www.securityfocus.com/bid/51177" }, { "trust": 0.6, "url": "http://www.nsfocus.net/vulndb/18390" }, { "trust": 0.3, "url": "http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/pages/default.aspx" }, { "trust": 0.3, "url": "http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/wincc-flexible/wincc-flexible-runtime/user-interface/pages/default.aspx" }, { "trust": 0.3, "url": "http://xs-sniper.com/blog/2011/12/20/the-siemens-simatic-remote-authentication-bypass-that-doesnt-exist/" }, { "trust": 0.3, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01a.pdf" }, { "trust": 0.3, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-11-356-01.pdf" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2011-5448" }, { "db": "VULHUB", "id": "VHN-52453" }, { "db": "BID", "id": "51177" }, { "db": "JVNDB", "id": "JVNDB-2012-001310" }, { "db": "CNNVD", "id": "CNNVD-201112-422" }, { "db": "NVD", "id": "CVE-2011-4508" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "28828750-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5448" }, { "db": "VULHUB", "id": "VHN-52453" }, { "db": "BID", "id": "51177" }, { "db": "JVNDB", "id": "JVNDB-2012-001310" }, { "db": "CNNVD", "id": "CNNVD-201112-422" }, { "db": "NVD", "id": "CVE-2011-4508" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2011-12-26T00:00:00", "db": "IVD", "id": "28828750-2354-11e6-abef-000c29c66e3d" }, { "date": "2011-12-26T00:00:00", "db": "CNVD", "id": "CNVD-2011-5448" }, { "date": "2012-02-03T00:00:00", "db": "VULHUB", "id": "VHN-52453" }, { "date": "2011-12-22T00:00:00", "db": "BID", "id": "51177" }, { "date": "2012-02-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001310" }, { "date": "1900-01-01T00:00:00", "db": "CNNVD", "id": "CNNVD-201112-422" }, { "date": "2012-02-03T20:55:01.250000", "db": "NVD", "id": "CVE-2011-4508" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2016-03-15T00:00:00", "db": "CNVD", "id": "CNVD-2011-5448" }, { "date": "2012-02-07T00:00:00", "db": "VULHUB", "id": "VHN-52453" }, { "date": "2012-04-18T21:20:00", "db": "BID", "id": "51177" }, { "date": "2012-02-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001310" }, { "date": "2012-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-201112-422" }, { "date": "2024-11-21T01:32:26.773000", "db": "NVD", "id": "CVE-2011-4508" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201112-422" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Siemens Product HMI Web Vulnerability that prevents authentication on the server", "sources": [ { "db": "JVNDB", "id": "JVNDB-2012-001310" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "authorization issue", "sources": [ { "db": "CNNVD", "id": "CNNVD-201112-422" } ], "trust": 0.6 } }
var-201202-0166
Vulnerability from variot
miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request. Siemens SIMATIC is an automation software in a single engineering environment. A security vulnerability exists in the Siemens SIMATIC WinCC HMI web server. The HMI web server does not properly validate the HTTP request. The first byte in the URL is manipulated. Siemens SIMATIC WinCC is prone to an HTTP-header-injection issue, a directory-traversal issue, and an arbitrary memory-read access issue because the application fails to properly sanitize user-supplied input. A remote attacker can exploit these issues to gain elevated privileges, obtain sensitive information, or cause denial-of-service conditions. The vulnerability stems from the failure of miniweb.exe in the HMI web server to correctly handle URLs starting with the 0xfa character
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0166", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "mp" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "tp" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "op" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2007" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2005" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2004" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "comfort_panels" }, { "model": "wincc runtime advanced", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "v11" }, { "model": "wincc", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "v11" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "mobile_panels" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2004" }, { "model": "wincc flexible runtime", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2007" }, { "model": "wincc", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "v11" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2005" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "v11" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "sp2 update 1" }, { "model": "simatic wincc", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "v11\\\\" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "comfort panels" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "v11" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "mobile panels" }, { "model": "simatic wincc flexible rumtime", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": null, "scope": "eq", "trust": 0.6, "vendor": "wincc flexible", "version": "2008" }, { "model": "simatic wincc flexible runtime", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic hmi panels", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "wincc flexible runtime", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "wincc", "version": "v11" }, { "model": "simatic wincc flexible runtime", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2004" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2005" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2007" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc", "version": "*" }, { "model": "comfort panels", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "mobile panels", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "mp", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "op", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "tp", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc runtime advanced", "version": "v11" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible runtime", "version": "*" } ], "sources": [ { "db": "IVD", "id": "28903b3e-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0469" }, { "db": "BID", "id": "51836" }, { "db": "JVNDB", "id": "JVNDB-2012-001321" }, { "db": "CNNVD", "id": "CNNVD-201202-094" }, { "db": "NVD", "id": "CVE-2011-4879" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:siemens:simatic_hmi_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_flexible", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_flexible_runtime", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2012-001321" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "ICS-CERT", "sources": [ { "db": "BID", "id": "51836" }, { "db": "CNNVD", "id": "CNNVD-201202-094" } ], "trust": 0.9 }, "cve": "CVE-2011-4879", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 8.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2011-4879", "impactScore": 7.8, "integrityImpact": "NONE", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 8.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "28903b3e-2354-11e6-abef-000c29c66e3d", "impactScore": 7.8, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 8.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "VHN-52824", "impactScore": 7.8, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:C", "version": "2.0" } ], "cvssV3": [], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2011-4879", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2011-4879", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-201202-094", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "28903b3e-2354-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-52824", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "IVD", "id": "28903b3e-2354-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-52824" }, { "db": "JVNDB", "id": "JVNDB-2012-001321" }, { "db": "CNNVD", "id": "CNNVD-201202-094" }, { "db": "NVD", "id": "CVE-2011-4879" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request. Siemens SIMATIC is an automation software in a single engineering environment. A security vulnerability exists in the Siemens SIMATIC WinCC HMI web server. The HMI web server does not properly validate the HTTP request. The first byte in the URL is manipulated. Siemens SIMATIC WinCC is prone to an HTTP-header-injection issue, a directory-traversal issue, and an arbitrary memory-read access issue because the application fails to properly sanitize user-supplied input. \nA remote attacker can exploit these issues to gain elevated privileges, obtain sensitive information, or cause denial-of-service conditions. The vulnerability stems from the failure of miniweb.exe in the HMI web server to correctly handle URLs starting with the 0xfa character", "sources": [ { "db": "NVD", "id": "CVE-2011-4879" }, { "db": "JVNDB", "id": "JVNDB-2012-001321" }, { "db": "CNVD", "id": "CNVD-2012-0469" }, { "db": "BID", "id": "51836" }, { "db": "IVD", "id": "28903b3e-2354-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-52824" } ], "trust": 2.7 }, "exploit_availability": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/exploit_availability#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "reference": "https://www.scap.org.cn/vuln/vhn-52824", "trust": 0.1, "type": "unknown" } ], "sources": [ { "db": "VULHUB", "id": "VHN-52824" } ] }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2011-4879", "trust": 3.6 }, { "db": "ICS CERT", "id": "ICSA-12-030-01", "trust": 3.4 }, { "db": "SIEMENS", "id": "SSA-345442", "trust": 1.7 }, { "db": "ICS CERT ALERT", "id": "ICS-ALERT-11-332-02A", "trust": 1.1 }, { "db": "ICS CERT ALERT", "id": "ICS-ALERT-11-332-02", "trust": 1.1 }, { "db": "OSVDB", "id": "77384", "trust": 1.1 }, { "db": "EXPLOIT-DB", "id": "18166", "trust": 1.1 }, { "db": "CNNVD", "id": "CNNVD-201202-094", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2012-0469", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2012-001321", "trust": 0.8 }, { "db": "NSFOCUS", "id": "18633", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-12-030-01A", "trust": 0.3 }, { "db": "BID", "id": "51836", "trust": 0.3 }, { "db": "IVD", "id": "28903B3E-2354-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-52824", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "28903b3e-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0469" }, { "db": "VULHUB", "id": "VHN-52824" }, { "db": "BID", "id": "51836" }, { "db": "JVNDB", "id": "JVNDB-2012-001321" }, { "db": "CNNVD", "id": "CNNVD-201202-094" }, { "db": "NVD", "id": "CVE-2011-4879" } ] }, "id": "VAR-201202-0166", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "28903b3e-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0469" }, { "db": "VULHUB", "id": "VHN-52824" } ], "trust": 1.5153960400000002 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "28903b3e-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0469" } ] }, "last_update_date": "2024-11-23T21:46:29.417000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-345442", "trust": 0.8, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "title": "\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc", "trust": 0.8, "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx" }, { "title": "Top Page", "trust": 0.8, "url": "http://www.siemens.com/entry/jp/ja/" }, { "title": "Patch for Siemens SIMATIC WinCC HMI Vulnerability (CNVD-2012-0469)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/9075" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2012-0469" }, { "db": "JVNDB", "id": "JVNDB-2012-001321" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-20", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-52824" }, { "db": "JVNDB", "id": "JVNDB-2012-001321" }, { "db": "NVD", "id": "CVE-2011-4879" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.4, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01.pdf" }, { "trust": 1.7, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "trust": 1.1, "url": "http://www.exploit-db.com/exploits/18166" }, { "trust": 1.1, "url": "http://aluigi.org/adv/winccflex_1-adv.txt" }, { "trust": 1.1, "url": "http://www.us-cert.gov/control_systems/pdf/ics-alert-11-332-02.pdf" }, { "trust": 1.1, "url": "http://www.us-cert.gov/control_systems/pdf/ics-alert-11-332-02a.pdf" }, { "trust": 1.1, "url": "http://www.osvdb.org/77384" }, { "trust": 1.1, "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71453" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4879" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4879" }, { "trust": 0.6, "url": "http://aluigi.altervista.org/adv/winccflex_1-adv.txt" }, { "trust": 0.6, "url": "http://www.nsfocus.net/vulndb/18633" }, { "trust": 0.3, "url": "http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/scada/pages/default.aspx" }, { "trust": 0.3, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01a.pdf" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2012-0469" }, { "db": "VULHUB", "id": "VHN-52824" }, { "db": "BID", "id": "51836" }, { "db": "JVNDB", "id": "JVNDB-2012-001321" }, { "db": "CNNVD", "id": "CNNVD-201202-094" }, { "db": "NVD", "id": "CVE-2011-4879" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "28903b3e-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0469" }, { "db": "VULHUB", "id": "VHN-52824" }, { "db": "BID", "id": "51836" }, { "db": "JVNDB", "id": "JVNDB-2012-001321" }, { "db": "CNNVD", "id": "CNNVD-201202-094" }, { "db": "NVD", "id": "CVE-2011-4879" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2012-02-07T00:00:00", "db": "IVD", "id": "28903b3e-2354-11e6-abef-000c29c66e3d" }, { "date": "2012-02-07T00:00:00", "db": "CNVD", "id": "CNVD-2012-0469" }, { "date": "2012-02-03T00:00:00", "db": "VULHUB", "id": "VHN-52824" }, { "date": "2012-02-02T00:00:00", "db": "BID", "id": "51836" }, { "date": "2012-02-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001321" }, { "date": "2012-02-07T00:00:00", "db": "CNNVD", "id": "CNNVD-201202-094" }, { "date": "2012-02-03T20:55:02.077000", "db": "NVD", "id": "CVE-2011-4879" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2012-02-07T00:00:00", "db": "CNVD", "id": "CNVD-2012-0469" }, { "date": "2017-08-29T00:00:00", "db": "VULHUB", "id": "VHN-52824" }, { "date": "2012-04-18T21:20:00", "db": "BID", "id": "51836" }, { "date": "2012-02-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001321" }, { "date": "2012-02-07T00:00:00", "db": "CNNVD", "id": "CNNVD-201202-094" }, { "date": "2024-11-21T01:33:12.360000", "db": "NVD", "id": "CVE-2011-4879" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201202-094" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Siemens Product HMI Web Vulnerability to read data from arbitrary memory locations on the server", "sources": [ { "db": "JVNDB", "id": "JVNDB-2012-001321" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Input validation", "sources": [ { "db": "IVD", "id": "28903b3e-2354-11e6-abef-000c29c66e3d" }, { "db": "CNNVD", "id": "CNNVD-201202-094" } ], "trust": 0.8 } }
var-201812-0344
Vulnerability from variot
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. plural SIMATIC The product contains an open redirect vulnerability.Information may be obtained and information may be altered. Siemens SIMATIC HMI Comfort Panels are all Germany's Siemens (Siemens) company HMI software for control and monitoring of machines and equipment.
The webserver in several Siemens products has an open redirection vulnerability. Siemens SIMATIC Panels is prone to following security vulnerabilities: 1. An open-redirection vulnerability 2. A directory-traversal vulnerability Remote attackers may use a specially crafted request with directory-traversal sequences ('../') to retrieve arbitrary files from the affected system in the context of the application or by constructing a crafted URI and enticing a user to follow it and when an unsuspecting victim follows the link, they may be redirected to an attacker-controlled site
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201812-0344", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic wincc runtime", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "15.0" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "15.0" }, { "model": "simatic hmi mp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi op", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort panels", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "15.0" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "15.0" }, { "model": "simatic hmi comfort outdoor panels", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "15.0" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "15.0" }, { "model": "simatic wincc \\", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "15.0" }, { "model": "simatic hmi tp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "15.0" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "15.0" }, { "model": "simatic hmi comfort outdoor panels", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi comfort panels", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime professional", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi classic devices", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic hmi comfort outdoor panels 7\" \u0026 15\" update", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "154" }, { "model": "simatic hmi comfort panels 4\"-22\" update", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "154" }, { "model": "simatic hmi ktp mobile panels update", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "154" }, { "model": "simatic wincc update", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "154" }, { "model": "simatic wincc runtime advanced update", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "154" }, { "model": "simatic wincc runtime professional update", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "154" }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "simatic wincc runtime", "version": "*" }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15" }, { "model": "simatic wincc runtime professional sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "14" }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "14" }, { "model": "simatic wincc runtime professional sp2", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "13" }, { "model": "simatic wincc runtime professional sp1 upd2", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "13" }, { "model": "simatic wincc runtime professional sp update", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1319" }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "13" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15" }, { "model": "simatic wincc runtime advanced sp1 upd2", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "13" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "13" }, { "model": "simatic wincc runtime advanced sp1 upd5", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "12" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "12" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc update", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v135" }, { "model": "simatic wincc sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v12" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v120" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v110" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v15" }, { "model": "simatic wincc update", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v136" }, { "model": "simatic wincc sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v13" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v13" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v10" }, { "model": "simatic hmi ktp mobile panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "22" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15" }, { "model": "simatic hmi comfort panels sp1 upd2", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "13" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "13" }, { "model": "simatic hmi comfort panels sp1 upd5", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "12" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "12" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi comfort outdoor panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi classic devices", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc runtime professional update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "154" }, { "model": "simatic wincc runtime advanced update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "154" }, { "model": "simatic wincc update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "154" }, { "model": "simatic hmi ktp mobile panels update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "154" }, { "model": "simatic hmi comfort panels update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "154" }, { "model": "simatic hmi comfort outdoor panels update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "154" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi comfort panels", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi mp", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi op", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi comfort outdoor panels", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi ktp mobile panels ktp400f", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi ktp mobile panels ktp700", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi ktp mobile panels ktp700f", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi ktp mobile panels ktp900", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi ktp mobile panels ktp900f", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic wincc tia portal", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi tp", "version": "*" } ], "sources": [ { "db": "IVD", "id": "e30112c1-39ab-11e9-9eae-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-24247" }, { "db": "BID", "id": "105922" }, { "db": "JVNDB", "id": "JVNDB-2018-014526" }, { "db": "NVD", "id": "CVE-2018-13813" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_outdoor_panels_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_runtime_professional", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-014526" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Hosni Tounsi from Carthage Red Team", "sources": [ { "db": "BID", "id": "105922" } ], "trust": 0.3 }, "cve": "CVE-2018-13813", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "CVE-2018-13813", "impactScore": 4.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2018-24247", "impactScore": 6.9, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:C/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "NONE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "e30112c1-39ab-11e9-9eae-000c29342cb1", "impactScore": 6.9, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:N/I:C/A:N", "version": "2.9 [IVD]" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "NONE", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "VHN-123910", "impactScore": 4.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2018-13813", "impactScore": 5.2, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-13813", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2018-13813", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2018-24247", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201811-483", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "e30112c1-39ab-11e9-9eae-000c29342cb1", "trust": 0.2, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-123910", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "IVD", "id": "e30112c1-39ab-11e9-9eae-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-24247" }, { "db": "VULHUB", "id": "VHN-123910" }, { "db": "JVNDB", "id": "JVNDB-2018-014526" }, { "db": "CNNVD", "id": "CNNVD-201811-483" }, { "db": "NVD", "id": "CVE-2018-13813" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions \u003c V15 Update 4), SIMATIC WinCC Runtime Professional (All versions \u003c V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions \u003c V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. plural SIMATIC The product contains an open redirect vulnerability.Information may be obtained and information may be altered. Siemens SIMATIC HMI Comfort Panels are all Germany\u0027s Siemens (Siemens) company HMI software for control and monitoring of machines and equipment. \n\nThe webserver in several Siemens products has an open redirection vulnerability. Siemens SIMATIC Panels is prone to following security vulnerabilities:\n1. An open-redirection vulnerability\n2. A directory-traversal vulnerability\nRemote attackers may use a specially crafted request with directory-traversal sequences (\u0027../\u0027) to retrieve arbitrary files from the affected system in the context of the application or by constructing a crafted URI and enticing a user to follow it and when an unsuspecting victim follows the link, they may be redirected to an attacker-controlled site", "sources": [ { "db": "NVD", "id": "CVE-2018-13813" }, { "db": "JVNDB", "id": "JVNDB-2018-014526" }, { "db": "CNVD", "id": "CNVD-2018-24247" }, { "db": "BID", "id": "105922" }, { "db": "IVD", "id": "e30112c1-39ab-11e9-9eae-000c29342cb1" }, { "db": "VULHUB", "id": "VHN-123910" } ], "trust": 2.7 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-13813", "trust": 3.6 }, { "db": "SIEMENS", "id": "SSA-233109", "trust": 2.3 }, { "db": "ICS CERT", "id": "ICSA-18-317-08", "trust": 2.3 }, { "db": "BID", "id": "105922", "trust": 2.0 }, { "db": "CNNVD", "id": "CNNVD-201811-483", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2018-24247", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2018-014526", "trust": 0.8 }, { "db": "IVD", "id": "E30112C1-39AB-11E9-9EAE-000C29342CB1", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-123910", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "e30112c1-39ab-11e9-9eae-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-24247" }, { "db": "VULHUB", "id": "VHN-123910" }, { "db": "BID", "id": "105922" }, { "db": "JVNDB", "id": "JVNDB-2018-014526" }, { "db": "CNNVD", "id": "CNNVD-201811-483" }, { "db": "NVD", "id": "CVE-2018-13813" } ] }, "id": "VAR-201812-0344", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "e30112c1-39ab-11e9-9eae-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-24247" }, { "db": "VULHUB", "id": "VHN-123910" } ], "trust": 1.59438617 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "e30112c1-39ab-11e9-9eae-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-24247" } ] }, "last_update_date": "2024-11-23T22:17:14.847000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-233109", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf" }, { "title": "Patch for Multiple Siemens products open redirection vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/176377" }, { "title": "Multiple Siemens Product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=86884" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-24247" }, { "db": "JVNDB", "id": "JVNDB-2018-014526" }, { "db": "CNNVD", "id": "CNNVD-201811-483" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-601", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-123910" }, { "db": "JVNDB", "id": "JVNDB-2018-014526" }, { "db": "NVD", "id": "CVE-2018-13813" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf" }, { "trust": 2.3, "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-317-08" }, { "trust": 1.7, "url": "http://www.securityfocus.com/bid/105922" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-13813" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-13813" }, { "trust": 0.3, "url": "http://subscriber.communications.siemens.com/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-24247" }, { "db": "VULHUB", "id": "VHN-123910" }, { "db": "BID", "id": "105922" }, { "db": "JVNDB", "id": "JVNDB-2018-014526" }, { "db": "CNNVD", "id": "CNNVD-201811-483" }, { "db": "NVD", "id": "CVE-2018-13813" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "e30112c1-39ab-11e9-9eae-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-24247" }, { "db": "VULHUB", "id": "VHN-123910" }, { "db": "BID", "id": "105922" }, { "db": "JVNDB", "id": "JVNDB-2018-014526" }, { "db": "CNNVD", "id": "CNNVD-201811-483" }, { "db": "NVD", "id": "CVE-2018-13813" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-11-29T00:00:00", "db": "IVD", "id": "e30112c1-39ab-11e9-9eae-000c29342cb1" }, { "date": "2018-11-29T00:00:00", "db": "CNVD", "id": "CNVD-2018-24247" }, { "date": "2018-12-13T00:00:00", "db": "VULHUB", "id": "VHN-123910" }, { "date": "2018-11-14T00:00:00", "db": "BID", "id": "105922" }, { "date": "2019-03-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-014526" }, { "date": "2018-11-15T00:00:00", "db": "CNNVD", "id": "CNNVD-201811-483" }, { "date": "2018-12-13T16:29:00.320000", "db": "NVD", "id": "CVE-2018-13813" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-08-22T00:00:00", "db": "CNVD", "id": "CNVD-2018-24247" }, { "date": "2019-10-09T00:00:00", "db": "VULHUB", "id": "VHN-123910" }, { "date": "2018-11-14T00:00:00", "db": "BID", "id": "105922" }, { "date": "2019-03-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-014526" }, { "date": "2019-10-17T00:00:00", "db": "CNNVD", "id": "CNNVD-201811-483" }, { "date": "2024-11-21T03:48:07.380000", "db": "NVD", "id": "CVE-2018-13813" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201811-483" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural SIMATIC Open redirect vulnerability in products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-014526" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Input validation error", "sources": [ { "db": "IVD", "id": "e30112c1-39ab-11e9-9eae-000c29342cb1" }, { "db": "BID", "id": "105922" }, { "db": "CNNVD", "id": "CNNVD-201811-483" } ], "trust": 1.1 } }
var-201905-0115
Vulnerability from variot
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known. plural SIMATIC The product contains a cross-site scripting vulnerability.Information may be obtained and information may be altered. Multiple Siemens Products are prone to following security vulnerabilities: 1. An information-disclosure vulnerability 2. A cross-site-scripting vulnerability 3. A security vulnerability An attacker may leverage these issues to obtain potentially sensitive information and to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and to launch other attacks. Siemens SIMATIC WinCC, etc. are all products of Siemens (Siemens) in Germany. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. Siemens SIMATIC HMI Comfort Panels is a touch panel device. Siemens SIMATIC HMI Comfort Outdoor Panels is a touch panel device specially designed for outdoor use. The vulnerability stems from the lack of correct validation of client data in WEB applications
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201905-0115", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic hmi comfort outdoor panels", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic wincc runtime", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic wincc \\", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi mp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort panels", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi op", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi tp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort outdoor panels", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi comfort panels", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime professional", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15.1" }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15.1" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v15.1" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v15" }, { "model": "simatic hmi ktp mobile panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15" }, { "model": "simatic hmi comfort outdoor panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15" }, { "model": "simatic hmi classic devices", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc runtime professional update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "v15.11" }, { "model": "simatic wincc runtime advanced update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "15.11" }, { "model": "simatic wincc update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "v15.11" }, { "model": "simatic hmi ktp mobile update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "15.11" }, { "model": "simatic hmi comfort panels update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "15.11" }, { "model": "simatic hmi comfort outdoor panels update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "15.11" } ], "sources": [ { "db": "BID", "id": "108412" }, { "db": "JVNDB", "id": "JVNDB-2019-004634" }, { "db": "NVD", "id": "CVE-2019-6577" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_outdoor_panels_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_runtime_professional", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-004634" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens ProductCERT reported these vulnerabilities to NCCIC.,Siemens ProductCERT", "sources": [ { "db": "CNNVD", "id": "CNNVD-201905-588" } ], "trust": 0.6 }, "cve": "CVE-2019-6577", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "exploitabilityScore": 6.8, "id": "CVE-2019-6577", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "LOW", "trust": 1.8, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "VULHUB", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "exploitabilityScore": 6.8, "id": "VHN-158012", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "LOW", "trust": 0.1, "vectorString": "AV:N/AC:M/AU:S/C:N/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 5.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 2.3, "id": "CVE-2019-6577", "impactScore": 2.7, "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "CHANGED", "trust": 1.8, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2019-6577", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2019-6577", "trust": 0.8, "value": "Medium" }, { "author": "CNNVD", "id": "CNNVD-201905-588", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULHUB", "id": "VHN-158012", "trust": 0.1, "value": "LOW" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-158012" }, { "db": "JVNDB", "id": "JVNDB-2019-004634" }, { "db": "CNNVD", "id": "CNNVD-201905-588" }, { "db": "NVD", "id": "CVE-2019-6577" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003c V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003c V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known. plural SIMATIC The product contains a cross-site scripting vulnerability.Information may be obtained and information may be altered. Multiple Siemens Products are prone to following security vulnerabilities:\n1. An information-disclosure vulnerability\n2. A cross-site-scripting vulnerability\n3. A security vulnerability\nAn attacker may leverage these issues to obtain potentially sensitive information and to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and to launch other attacks. Siemens SIMATIC WinCC, etc. are all products of Siemens (Siemens) in Germany. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. Siemens SIMATIC HMI Comfort Panels is a touch panel device. Siemens SIMATIC HMI Comfort Outdoor Panels is a touch panel device specially designed for outdoor use. The vulnerability stems from the lack of correct validation of client data in WEB applications", "sources": [ { "db": "NVD", "id": "CVE-2019-6577" }, { "db": "JVNDB", "id": "JVNDB-2019-004634" }, { "db": "BID", "id": "108412" }, { "db": "VULHUB", "id": "VHN-158012" } ], "trust": 1.98 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-6577", "trust": 2.8 }, { "db": "ICS CERT", "id": "ICSA-19-134-09", "trust": 2.8 }, { "db": "BID", "id": "108412", "trust": 2.0 }, { "db": "SIEMENS", "id": "SSA-804486", "trust": 1.7 }, { "db": "JVNDB", "id": "JVNDB-2019-004634", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201905-588", "trust": 0.7 }, { "db": "ICS CERT", "id": "ICSA-19-134-02", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2019.1716.2", "trust": 0.6 }, { "db": "CNVD", "id": "CNVD-2021-54365", "trust": 0.1 }, { "db": "VULHUB", "id": "VHN-158012", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-158012" }, { "db": "BID", "id": "108412" }, { "db": "JVNDB", "id": "JVNDB-2019-004634" }, { "db": "CNNVD", "id": "CNNVD-201905-588" }, { "db": "NVD", "id": "CVE-2019-6577" } ] }, "id": "VAR-201905-0115", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-158012" } ], "trust": 0.7545892989999999 }, "last_update_date": "2024-11-23T21:37:16.753000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-804486", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf" }, { "title": "Siemens SIMATIC Panels and WinCC Fixes for cross-site scripting vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=92738" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-004634" }, { "db": "CNNVD", "id": "CNNVD-201905-588" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-79", "trust": 1.9 }, { "problemtype": "CWE-80", "trust": 1.0 } ], "sources": [ { "db": "VULHUB", "id": "VHN-158012" }, { "db": "JVNDB", "id": "JVNDB-2019-004634" }, { "db": "NVD", "id": "CVE-2019-6577" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "http://www.securityfocus.com/bid/108412" }, { "trust": 1.9, "url": "https://www.us-cert.gov/ics/advisories/icsa-19-134-09" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-6577" }, { "trust": 0.9, "url": "http://subscriber.communications.siemens.com/" }, { "trust": 0.9, "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-134-09" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-6577" }, { "trust": 0.6, "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-134-02-0" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/simatic-wincc-multiple-vulnerabilities-29288" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/80946" } ], "sources": [ { "db": "VULHUB", "id": "VHN-158012" }, { "db": "BID", "id": "108412" }, { "db": "JVNDB", "id": "JVNDB-2019-004634" }, { "db": "CNNVD", "id": "CNNVD-201905-588" }, { "db": "NVD", "id": "CVE-2019-6577" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-158012" }, { "db": "BID", "id": "108412" }, { "db": "JVNDB", "id": "JVNDB-2019-004634" }, { "db": "CNNVD", "id": "CNNVD-201905-588" }, { "db": "NVD", "id": "CVE-2019-6577" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-05-14T00:00:00", "db": "VULHUB", "id": "VHN-158012" }, { "date": "2019-05-14T00:00:00", "db": "BID", "id": "108412" }, { "date": "2019-06-05T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-004634" }, { "date": "2019-05-14T00:00:00", "db": "CNNVD", "id": "CNNVD-201905-588" }, { "date": "2019-05-14T20:29:04.623000", "db": "NVD", "id": "CVE-2019-6577" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-05-22T00:00:00", "db": "VULHUB", "id": "VHN-158012" }, { "date": "2019-05-14T00:00:00", "db": "BID", "id": "108412" }, { "date": "2019-07-09T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-004634" }, { "date": "2019-05-23T00:00:00", "db": "CNNVD", "id": "CNNVD-201905-588" }, { "date": "2024-11-21T04:46:44.267000", "db": "NVD", "id": "CVE-2019-6577" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201905-588" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural SIMATIC Product cross-site scripting vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-004634" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "XSS", "sources": [ { "db": "CNNVD", "id": "CNNVD-201905-588" } ], "trust": 0.6 } }
var-202105-0691
Vulnerability from variot
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition. Several Siemens products contain resource exhaustion vulnerabilities.Denial of service (DoS) It may be put into a state. Siemens SmartVNC is an industrial control equipment of Siemens (Siemens), Germany.
SmartVNC has a resource management error vulnerability. Attackers can use this vulnerability to cause program denial of service. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202105-0691", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics sl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinamics gm150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic wincc runtime advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinamics sm150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinamics sm150i", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic wincc runtime advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gh150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics sm120", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics sh150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics sh150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sl150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sm120", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sm150i", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi comfort outdoor panels 7\"", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics gh150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sm150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics gl150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics gm150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "smartvnc", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37749" }, { "db": "JVNDB", "id": "JVNDB-2021-006950" }, { "db": "NVD", "id": "CVE-2021-27385" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-575" } ], "trust": 0.6 }, "cve": "CVE-2021-27385", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2021-27385", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2021-37749", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2021-27385", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-27385", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-27385", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2021-27385", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-37749", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202105-575", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-27385", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37749" }, { "db": "VULMON", "id": "CVE-2021-27385" }, { "db": "JVNDB", "id": "JVNDB-2021-006950" }, { "db": "CNNVD", "id": "CNNVD-202105-575" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "NVD", "id": "CVE-2021-27385" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition. Several Siemens products contain resource exhaustion vulnerabilities.Denial of service (DoS) It may be put into a state. Siemens SmartVNC is an industrial control equipment of Siemens (Siemens), Germany. \n\r\n\r\nSmartVNC has a resource management error vulnerability. Attackers can use this vulnerability to cause program denial of service. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements", "sources": [ { "db": "NVD", "id": "CVE-2021-27385" }, { "db": "JVNDB", "id": "JVNDB-2021-006950" }, { "db": "CNVD", "id": "CNVD-2021-37749" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULMON", "id": "CVE-2021-27385" } ], "trust": 2.79 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-27385", "trust": 3.9 }, { "db": "ICS CERT", "id": "ICSA-21-131-12", "trust": 3.1 }, { "db": "SIEMENS", "id": "SSA-286838", "trust": 1.7 }, { "db": "SIEMENS", "id": "SSA-538778", "trust": 1.7 }, { "db": "JVN", "id": "JVNVU91051134", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-006950", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-37749", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-21-131-04", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021051206", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202105-575", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-27385", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37749" }, { "db": "VULMON", "id": "CVE-2021-27385" }, { "db": "JVNDB", "id": "JVNDB-2021-006950" }, { "db": "CNNVD", "id": "CNNVD-202105-575" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "NVD", "id": "CVE-2021-27385" } ] }, "id": "VAR-202105-0691", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-37749" } ], "trust": 1.205898611111111 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37749" } ] }, "last_update_date": "2024-08-14T13:11:37.021000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-286838 Siemens\u00a0Security\u00a0Advisory", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "title": "Patch for Siemens SmartVNC Resource Management Error Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/268656" }, { "title": "Siemens SmartVNC Remediation of resource management error vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=151561" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=43c9c77785b8d29daef02185f41ca476" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=9465a8ef1f8c1b0042244cb02cfe271e" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37749" }, { "db": "VULMON", "id": "CVE-2021-27385" }, { "db": "JVNDB", "id": "JVNDB-2021-006950" }, { "db": "CNNVD", "id": "CNNVD-202105-575" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-400", "trust": 1.0 }, { "problemtype": "CWE-835", "trust": 1.0 }, { "problemtype": "Resource exhaustion (CWE-400) [ Other ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006950" }, { "db": "NVD", "id": "CVE-2021-27385" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.9, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu91051134/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-27385" }, { "trust": 0.8, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-131-12" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021051206" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/smartvnc-multiple-vulnerabilities-35360" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/400.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://cert-portal.siemens.com/productcert/txt/ssa-286838.txt" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37749" }, { "db": "VULMON", "id": "CVE-2021-27385" }, { "db": "JVNDB", "id": "JVNDB-2021-006950" }, { "db": "CNNVD", "id": "CNNVD-202105-575" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "NVD", "id": "CVE-2021-27385" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-37749" }, { "db": "VULMON", "id": "CVE-2021-27385" }, { "db": "JVNDB", "id": "JVNDB-2021-006950" }, { "db": "CNNVD", "id": "CNNVD-202105-575" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "NVD", "id": "CVE-2021-27385" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-05-28T00:00:00", "db": "CNVD", "id": "CNVD-2021-37749" }, { "date": "2021-05-12T00:00:00", "db": "VULMON", "id": "CVE-2021-27385" }, { "date": "2022-01-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-006950" }, { "date": "2021-05-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-575" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-05-12T14:15:11.727000", "db": "NVD", "id": "CVE-2021-27385" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-05-28T00:00:00", "db": "CNVD", "id": "CNVD-2021-37749" }, { "date": "2021-05-21T00:00:00", "db": "VULMON", "id": "CVE-2021-27385" }, { "date": "2022-01-26T07:30:00", "db": "JVNDB", "id": "JVNDB-2021-006950" }, { "date": "2022-10-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-575" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2022-10-25T19:56:01.580000", "db": "NVD", "id": "CVE-2021-27385" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-575" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens SmartVNC Resource Management Error Vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2021-37749" }, { "db": "CNNVD", "id": "CNNVD-202105-575" } ], "trust": 1.2 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "resource management error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-575" } ], "trust": 0.6 } }
var-201202-0165
Vulnerability from variot
Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI. plural Siemens Product HMI Web Server miniweb.exe Contains a directory traversal vulnerability.By a third party ..%5c ( Dot dot backslash ) including URI Any file may be read via. Siemens SIMATIC is an automation software in a single engineering environment. A security vulnerability exists in the Siemens SIMATIC WinCC HMI web server. The HMI web server listening on TCP ports 80 and 443 does not correctly verify the URL in the HTTP request, and builds a URL containing a specially crafted slash to perform a directory traversal attack and read any file in the file system. Siemens SIMATIC WinCC is prone to an HTTP-header-injection issue, a directory-traversal issue, and an arbitrary memory-read access issue because the application fails to properly sanitize user-supplied input. A remote attacker can exploit these issues to gain elevated privileges, obtain sensitive information, or cause denial-of-service conditions. A remote attacker can exploit this vulnerability to read arbitrary files by means of ../ (dotted backslashes) in the URL
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0165", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "mp" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "tp" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "op" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2005" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2004" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2007" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "comfort_panels" }, { "model": "wincc runtime advanced", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "v11" }, { "model": "wincc", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "v11" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "mobile_panels" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2004" }, { "model": "wincc flexible runtime", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2007" }, { "model": "wincc", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "v11" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2005" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "v11" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "sp2 update 1" }, { "model": "simatic wincc", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "v11\\\\" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "comfort panels" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "v11" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "mobile panels" }, { "model": "simatic wincc flexible rumtime", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": null, "scope": "eq", "trust": 0.6, "vendor": "wincc flexible", "version": "2008" }, { "model": "simatic hmi panels", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc flexible runtime", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "wincc flexible runtime", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "wincc", "version": "v11" }, { "model": "simatic wincc flexible runtime", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2004" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2005" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2007" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc", "version": "*" }, { "model": "comfort panels", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "mobile panels", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "mp", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "op", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "tp", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc runtime advanced", "version": "v11" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible runtime", "version": "*" } ], "sources": [ { "db": "IVD", "id": "2848847e-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0468" }, { "db": "BID", "id": "51836" }, { "db": "JVNDB", "id": "JVNDB-2012-001320" }, { "db": "CNNVD", "id": "CNNVD-201202-093" }, { "db": "NVD", "id": "CVE-2011-4878" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:siemens:simatic_hmi_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_flexible", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_flexible_runtime", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2012-001320" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "ICS-CERT", "sources": [ { "db": "BID", "id": "51836" }, { "db": "CNNVD", "id": "CNNVD-201202-093" } ], "trust": 0.9 }, "cve": "CVE-2011-4878", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 7.8, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CVE-2011-4878", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "NONE", "baseScore": 7.8, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "2848847e-2354-11e6-abef-000c29c66e3d", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "NONE", "baseScore": 7.8, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "VHN-52823", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:C/I:N/A:N", "version": "2.0" } ], "cvssV3": [], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2011-4878", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2011-4878", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-201202-093", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "2848847e-2354-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-52823", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "IVD", "id": "2848847e-2354-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-52823" }, { "db": "JVNDB", "id": "JVNDB-2012-001320" }, { "db": "CNNVD", "id": "CNNVD-201202-093" }, { "db": "NVD", "id": "CVE-2011-4878" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI. plural Siemens Product HMI Web Server miniweb.exe Contains a directory traversal vulnerability.By a third party ..%5c ( Dot dot backslash ) including URI Any file may be read via. Siemens SIMATIC is an automation software in a single engineering environment. A security vulnerability exists in the Siemens SIMATIC WinCC HMI web server. The HMI web server listening on TCP ports 80 and 443 does not correctly verify the URL in the HTTP request, and builds a URL containing a specially crafted slash to perform a directory traversal attack and read any file in the file system. Siemens SIMATIC WinCC is prone to an HTTP-header-injection issue, a directory-traversal issue, and an arbitrary memory-read access issue because the application fails to properly sanitize user-supplied input. \nA remote attacker can exploit these issues to gain elevated privileges, obtain sensitive information, or cause denial-of-service conditions. A remote attacker can exploit this vulnerability to read arbitrary files by means of ../ (dotted backslashes) in the URL", "sources": [ { "db": "NVD", "id": "CVE-2011-4878" }, { "db": "JVNDB", "id": "JVNDB-2012-001320" }, { "db": "CNVD", "id": "CNVD-2012-0468" }, { "db": "BID", "id": "51836" }, { "db": "IVD", "id": "2848847e-2354-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-52823" } ], "trust": 2.7 }, "exploit_availability": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/exploit_availability#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "reference": "https://www.scap.org.cn/vuln/vhn-52823", "trust": 0.1, "type": "unknown" } ], "sources": [ { "db": "VULHUB", "id": "VHN-52823" } ] }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2011-4878", "trust": 3.6 }, { "db": "ICS CERT", "id": "ICSA-12-030-01", "trust": 3.4 }, { "db": "SIEMENS", "id": "SSA-345442", "trust": 1.7 }, { "db": "ICS CERT ALERT", "id": "ICS-ALERT-11-332-02A", "trust": 1.1 }, { "db": "ICS CERT ALERT", "id": "ICS-ALERT-11-332-02", "trust": 1.1 }, { "db": "EXPLOIT-DB", "id": "18166", "trust": 1.1 }, { "db": "OSVDB", "id": "77383", "trust": 1.1 }, { "db": "CNNVD", "id": "CNNVD-201202-093", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2012-0468", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2012-001320", "trust": 0.8 }, { "db": "NSFOCUS", "id": "18633", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-12-030-01A", "trust": 0.3 }, { "db": "BID", "id": "51836", "trust": 0.3 }, { "db": "IVD", "id": "2848847E-2354-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-52823", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "2848847e-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0468" }, { "db": "VULHUB", "id": "VHN-52823" }, { "db": "BID", "id": "51836" }, { "db": "JVNDB", "id": "JVNDB-2012-001320" }, { "db": "CNNVD", "id": "CNNVD-201202-093" }, { "db": "NVD", "id": "CVE-2011-4878" } ] }, "id": "VAR-201202-0165", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "2848847e-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0468" }, { "db": "VULHUB", "id": "VHN-52823" } ], "trust": 1.5153960400000002 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "2848847e-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0468" } ] }, "last_update_date": "2024-11-23T21:46:29.262000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-345442", "trust": 0.8, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "title": "\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc", "trust": 0.8, "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx" }, { "title": "Top Page", "trust": 0.8, "url": "http://www.siemens.com/entry/jp/ja/" }, { "title": "Patch for Siemens SIMATIC WinCC HMI Directory Traversal Vulnerability (CNVD-2012-0468)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/9074" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2012-0468" }, { "db": "JVNDB", "id": "JVNDB-2012-001320" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-22", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-52823" }, { "db": "JVNDB", "id": "JVNDB-2012-001320" }, { "db": "NVD", "id": "CVE-2011-4878" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.4, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01.pdf" }, { "trust": 1.7, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "trust": 1.1, "url": "http://www.exploit-db.com/exploits/18166" }, { "trust": 1.1, "url": "http://aluigi.org/adv/winccflex_1-adv.txt" }, { "trust": 1.1, "url": "http://www.us-cert.gov/control_systems/pdf/ics-alert-11-332-02.pdf" }, { "trust": 1.1, "url": "http://www.us-cert.gov/control_systems/pdf/ics-alert-11-332-02a.pdf" }, { "trust": 1.1, "url": "http://www.osvdb.org/77383" }, { "trust": 1.1, "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71452" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4878" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4878" }, { "trust": 0.6, "url": "http://aluigi.altervista.org/adv/winccflex_1-adv.txt" }, { "trust": 0.6, "url": "http://www.nsfocus.net/vulndb/18633" }, { "trust": 0.3, "url": "http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/scada/pages/default.aspx" }, { "trust": 0.3, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01a.pdf" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2012-0468" }, { "db": "VULHUB", "id": "VHN-52823" }, { "db": "BID", "id": "51836" }, { "db": "JVNDB", "id": "JVNDB-2012-001320" }, { "db": "CNNVD", "id": "CNNVD-201202-093" }, { "db": "NVD", "id": "CVE-2011-4878" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "2848847e-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0468" }, { "db": "VULHUB", "id": "VHN-52823" }, { "db": "BID", "id": "51836" }, { "db": "JVNDB", "id": "JVNDB-2012-001320" }, { "db": "CNNVD", "id": "CNNVD-201202-093" }, { "db": "NVD", "id": "CVE-2011-4878" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2012-02-07T00:00:00", "db": "IVD", "id": "2848847e-2354-11e6-abef-000c29c66e3d" }, { "date": "2012-02-07T00:00:00", "db": "CNVD", "id": "CNVD-2012-0468" }, { "date": "2012-02-03T00:00:00", "db": "VULHUB", "id": "VHN-52823" }, { "date": "2012-02-02T00:00:00", "db": "BID", "id": "51836" }, { "date": "2012-02-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001320" }, { "date": "2012-02-07T00:00:00", "db": "CNNVD", "id": "CNNVD-201202-093" }, { "date": "2012-02-03T20:55:02.030000", "db": "NVD", "id": "CVE-2011-4878" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2012-02-07T00:00:00", "db": "CNVD", "id": "CNVD-2012-0468" }, { "date": "2017-08-29T00:00:00", "db": "VULHUB", "id": "VHN-52823" }, { "date": "2012-04-18T21:20:00", "db": "BID", "id": "51836" }, { "date": "2012-02-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001320" }, { "date": "2012-02-07T00:00:00", "db": "CNNVD", "id": "CNNVD-201202-093" }, { "date": "2024-11-21T01:33:11.850000", "db": "NVD", "id": "CVE-2011-4878" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201202-093" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Siemens Product HMI Web Server traversal vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2012-001320" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Path traversal", "sources": [ { "db": "IVD", "id": "2848847e-2354-11e6-abef-000c29c66e3d" }, { "db": "CNNVD", "id": "CNNVD-201202-093" } ], "trust": 0.8 } }
var-201202-0046
Vulnerability from variot
Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4510. plural Siemens Product HMI Web The server contains a cross-site scripting vulnerability. This vulnerability is CVE-2011-4510 This is a different vulnerability.By any third party, Web Script or HTML May be inserted. Siemens SIMATIC is an automation software in a single engineering environment. The SIMATIC HMI Smart Options web server has two separate cross-site scripting attacks that allow elevation of privilege, stealing data or corrupting services. SIMATIC HMI is prone to multiple unspecified cross-site scripting vulnerabilities because it fails to properly sanitize user-supplied input. An attacker may leverage these issues to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This can allow the attacker to steal cookie-based authentication credentials and launch other attacks
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0046", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "mp" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "op" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "tp" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "comfort_panels" }, { "model": "wincc runtime advanced", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "v11" }, { "model": "wincc", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "v11" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "mobile_panels" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.4, "vendor": "siemens", "version": "2007" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.4, "vendor": "siemens", "version": "2005" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.4, "vendor": "siemens", "version": "2004" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2004" }, { "model": "wincc flexible runtime", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2007" }, { "model": "wincc", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "v11" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2005" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2008" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "comfort panels" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "mobile panels" }, { "model": "simatic wincc", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "v11 sp2 update 1" }, { "model": "simatic wincc flexible", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "2008 sp3" }, { "model": "simatic wincc flexible rumtime", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "v11" }, { "model": null, "scope": "eq", "trust": 0.6, "vendor": "wincc flexible", "version": "2008" }, { "model": "simatic wincc flexible runtime", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "2008" }, { "model": "simatic hmi panels", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v11" }, { "model": "wincc flexible runtime", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "wincc", "version": "v11" }, { "model": "simatic hmi smart options", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2004" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2005" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2007" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc", "version": "*" }, { "model": "comfort panels", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "mobile panels", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "mp", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "op", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "tp", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc runtime advanced", "version": "v11" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible runtime", "version": "*" } ], "sources": [ { "db": "IVD", "id": "28629d64-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0461" }, { "db": "BID", "id": "51835" }, { "db": "JVNDB", "id": "JVNDB-2012-001313" }, { "db": "CNNVD", "id": "CNNVD-201202-086" }, { "db": "NVD", "id": "CVE-2011-4511" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:siemens:simatic_hmi_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_flexible", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_flexible_runtime", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2012-001313" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Billy Rios, Terry McCorkle, Shawn Merdinger, and Luigi Auriemma.", "sources": [ { "db": "BID", "id": "51835" } ], "trust": 0.3 }, "cve": "CVE-2011-4511", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "exploitabilityScore": 8.6, "id": "CVE-2011-4511", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "exploitabilityScore": 8.6, "id": "28629d64-2354-11e6-abef-000c29c66e3d", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.2, "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.9 [IVD]" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "exploitabilityScore": 8.6, "id": "VHN-52456", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:M/AU:N/C:N/I:P/A:N", "version": "2.0" } ], "cvssV3": [], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2011-4511", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2011-4511", "trust": 0.8, "value": "Medium" }, { "author": "CNNVD", "id": "CNNVD-201202-086", "trust": 0.6, "value": "MEDIUM" }, { "author": "IVD", "id": "28629d64-2354-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "MEDIUM" }, { "author": "VULHUB", "id": "VHN-52456", "trust": 0.1, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2011-4511", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "IVD", "id": "28629d64-2354-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-52456" }, { "db": "VULMON", "id": "CVE-2011-4511" }, { "db": "JVNDB", "id": "JVNDB-2012-001313" }, { "db": "CNNVD", "id": "CNNVD-201202-086" }, { "db": "NVD", "id": "CVE-2011-4511" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4510. plural Siemens Product HMI Web The server contains a cross-site scripting vulnerability. This vulnerability is CVE-2011-4510 This is a different vulnerability.By any third party, Web Script or HTML May be inserted. Siemens SIMATIC is an automation software in a single engineering environment. The SIMATIC HMI Smart Options web server has two separate cross-site scripting attacks that allow elevation of privilege, stealing data or corrupting services. SIMATIC HMI is prone to multiple unspecified cross-site scripting vulnerabilities because it fails to properly sanitize user-supplied input. \nAn attacker may leverage these issues to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This can allow the attacker to steal cookie-based authentication credentials and launch other attacks", "sources": [ { "db": "NVD", "id": "CVE-2011-4511" }, { "db": "JVNDB", "id": "JVNDB-2012-001313" }, { "db": "CNVD", "id": "CNVD-2012-0461" }, { "db": "BID", "id": "51835" }, { "db": "IVD", "id": "28629d64-2354-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-52456" }, { "db": "VULMON", "id": "CVE-2011-4511" } ], "trust": 2.79 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2011-4511", "trust": 3.7 }, { "db": "ICS CERT", "id": "ICSA-12-030-01", "trust": 3.5 }, { "db": "SIEMENS", "id": "SSA-345442", "trust": 1.8 }, { "db": "CNNVD", "id": "CNNVD-201202-086", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2012-0461", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2012-001313", "trust": 0.8 }, { "db": "NSFOCUS", "id": "19403", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-12-030-01A", "trust": 0.4 }, { "db": "BID", "id": "51835", "trust": 0.4 }, { "db": "IVD", "id": "28629D64-2354-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-52456", "trust": 0.1 }, { "db": "VULMON", "id": "CVE-2011-4511", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "28629d64-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0461" }, { "db": "VULHUB", "id": "VHN-52456" }, { "db": "VULMON", "id": "CVE-2011-4511" }, { "db": "BID", "id": "51835" }, { "db": "JVNDB", "id": "JVNDB-2012-001313" }, { "db": "CNNVD", "id": "CNNVD-201202-086" }, { "db": "NVD", "id": "CVE-2011-4511" } ] }, "id": "VAR-201202-0046", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "28629d64-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0461" }, { "db": "VULHUB", "id": "VHN-52456" } ], "trust": 1.52394115 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "28629d64-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0461" } ] }, "last_update_date": "2024-11-23T21:46:30.355000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-345442", "trust": 0.8, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "title": "\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc", "trust": 0.8, "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx" }, { "title": "Top Page", "trust": 0.8, "url": "http://www.siemens.com/entry/jp/ja/" }, { "title": "Patch for Siemens SIMATIC WinCC HMI Cross-Site Scripting Vulnerability (CNVD-2012-0461)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/9059" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2012-0461" }, { "db": "JVNDB", "id": "JVNDB-2012-001313" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-79", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-52456" }, { "db": "JVNDB", "id": "JVNDB-2012-001313" }, { "db": "NVD", "id": "CVE-2011-4511" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.5, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01.pdf" }, { "trust": 1.8, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4511" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4511" }, { "trust": 0.6, "url": "http://www.nsfocus.net/vulndb/19403" }, { "trust": 0.3, "url": "http://www.automation.siemens.com/mcms/automation/en/human-machine-interface/pages/default.aspx" }, { "trust": 0.3, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01a.pdf" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/79.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://www.securityfocus.com/bid/51835" }, { "trust": 0.1, "url": "https://ics-cert.us-cert.gov/advisories/icsa-12-030-01a" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2012-0461" }, { "db": "VULHUB", "id": "VHN-52456" }, { "db": "VULMON", "id": "CVE-2011-4511" }, { "db": "BID", "id": "51835" }, { "db": "JVNDB", "id": "JVNDB-2012-001313" }, { "db": "CNNVD", "id": "CNNVD-201202-086" }, { "db": "NVD", "id": "CVE-2011-4511" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "28629d64-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0461" }, { "db": "VULHUB", "id": "VHN-52456" }, { "db": "VULMON", "id": "CVE-2011-4511" }, { "db": "BID", "id": "51835" }, { "db": "JVNDB", "id": "JVNDB-2012-001313" }, { "db": "CNNVD", "id": "CNNVD-201202-086" }, { "db": "NVD", "id": "CVE-2011-4511" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2012-02-07T00:00:00", "db": "IVD", "id": "28629d64-2354-11e6-abef-000c29c66e3d" }, { "date": "2012-02-07T00:00:00", "db": "CNVD", "id": "CNVD-2012-0461" }, { "date": "2012-02-03T00:00:00", "db": "VULHUB", "id": "VHN-52456" }, { "date": "2012-02-03T00:00:00", "db": "VULMON", "id": "CVE-2011-4511" }, { "date": "2012-01-30T00:00:00", "db": "BID", "id": "51835" }, { "date": "2012-02-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001313" }, { "date": "2012-02-07T00:00:00", "db": "CNNVD", "id": "CNNVD-201202-086" }, { "date": "2012-02-03T20:55:01.407000", "db": "NVD", "id": "CVE-2011-4511" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2012-02-07T00:00:00", "db": "CNVD", "id": "CNVD-2012-0461" }, { "date": "2012-02-06T00:00:00", "db": "VULHUB", "id": "VHN-52456" }, { "date": "2012-02-06T00:00:00", "db": "VULMON", "id": "CVE-2011-4511" }, { "date": "2012-04-18T21:20:00", "db": "BID", "id": "51835" }, { "date": "2012-02-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001313" }, { "date": "2012-02-07T00:00:00", "db": "CNNVD", "id": "CNNVD-201202-086" }, { "date": "2024-11-21T01:32:27.130000", "db": "NVD", "id": "CVE-2011-4511" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201202-086" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Siemens Product HMI Web Server vulnerable to cross-site scripting", "sources": [ { "db": "JVNDB", "id": "JVNDB-2012-001313" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "XSS", "sources": [ { "db": "CNNVD", "id": "CNNVD-201202-086" } ], "trust": 0.6 } }
var-202105-0790
Vulnerability from variot
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the client side when sending data from the server, which could result in a Denial-of-Service condition. Several Siemens products are vulnerable to access to memory areas after buffer termination.Denial of service (DoS) It may be put into a state. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202105-0790", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic wincc runtime advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic wincc runtime advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi comfort outdoor panels 7\"", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi comfort outdoor panels 15\"", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi comfort panels 4\"", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi comfort panels 22\"", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006946" }, { "db": "NVD", "id": "CVE-2021-25661" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-546" } ], "trust": 0.6 }, "cve": "CVE-2021-25661", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2021-25661", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2021-25661", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-25661", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-25661", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2021-25661", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202105-546", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-25661", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-25661" }, { "db": "JVNDB", "id": "JVNDB-2021-006946" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-546" }, { "db": "NVD", "id": "CVE-2021-25661" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the client side when sending data from the server, which could result in a Denial-of-Service condition. Several Siemens products are vulnerable to access to memory areas after buffer termination.Denial of service (DoS) It may be put into a state. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements", "sources": [ { "db": "NVD", "id": "CVE-2021-25661" }, { "db": "JVNDB", "id": "JVNDB-2021-006946" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULMON", "id": "CVE-2021-25661" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-25661", "trust": 3.3 }, { "db": "ICS CERT", "id": "ICSA-21-131-12", "trust": 2.5 }, { "db": "SIEMENS", "id": "SSA-538778", "trust": 1.7 }, { "db": "JVN", "id": "JVNVU91051134", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-006946", "trust": 0.8 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021051206", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202105-546", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-25661", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-25661" }, { "db": "JVNDB", "id": "JVNDB-2021-006946" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-546" }, { "db": "NVD", "id": "CVE-2021-25661" } ] }, "id": "VAR-202105-0790", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.465033575 }, "last_update_date": "2024-08-14T13:12:15.959000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-538778", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "title": "Siemens SmartVNC Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=155974" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=9465a8ef1f8c1b0042244cb02cfe271e" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-25661" }, { "db": "JVNDB", "id": "JVNDB-2021-006946" }, { "db": "CNNVD", "id": "CNNVD-202105-546" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-788", "trust": 1.0 }, { "problemtype": "Access to memory area after buffer termination (CWE-788) [ Other ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006946" }, { "db": "NVD", "id": "CVE-2021-25661" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-25661" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu91051134/" }, { "trust": 0.8, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-131-12" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021051206" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/smartvnc-multiple-vulnerabilities-35360" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/788.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://cert-portal.siemens.com/productcert/txt/ssa-538778.txt" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-25661" }, { "db": "JVNDB", "id": "JVNDB-2021-006946" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-546" }, { "db": "NVD", "id": "CVE-2021-25661" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-25661" }, { "db": "JVNDB", "id": "JVNDB-2021-006946" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-546" }, { "db": "NVD", "id": "CVE-2021-25661" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-05-12T00:00:00", "db": "VULMON", "id": "CVE-2021-25661" }, { "date": "2022-01-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-006946" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-05-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-546" }, { "date": "2021-05-12T14:15:11.300000", "db": "NVD", "id": "CVE-2021-25661" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-05-21T00:00:00", "db": "VULMON", "id": "CVE-2021-25661" }, { "date": "2022-01-26T07:30:00", "db": "JVNDB", "id": "JVNDB-2021-006946" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-10-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-546" }, { "date": "2021-12-16T18:26:51.387000", "db": "NVD", "id": "CVE-2021-25661" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-546" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Vulnerabilities in access to memory areas after buffer termination in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006946" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-546" } ], "trust": 1.2 } }
var-202007-1238
Vulnerability from variot
A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information. Several Siemens products contain vulnerabilities in the transmission of important information in clear text.Information may be obtained. SIMATIC HMI Panels are used for operator control, monitoring of machines and equipment. SIMATIC WinCC Runtime Advanced is a visual runtime platform, monitoring of machines and equipment. SIPLUS extreme products are designed to operate under extreme conditions. It is based on Imatic, LOGO! SITOP, SINAMICS, SIMOTION, SCALANCE or other equipment
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202007-1238", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic wincc runtime advanced", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic hmi comfort panels", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic hmi basic panels 2nd generation", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic hmi basic panels 1st generation", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic hmi mobile panels 2nd generation", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi basic panels 2nd generation", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp700f mobile arctic", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi basic panels 1st generation", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi mobile panels 2nd generation", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp700f mobile arctic", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-40613" }, { "db": "JVNDB", "id": "JVNDB-2020-008612" }, { "db": "NVD", "id": "CVE-2020-7592" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/h:siemens:simatic_hmi_basic_panels_generation_1", "vulnerable": true }, { "cpe22Uri": "cpe:/h:siemens:simatic_hmi_basic_panels_generation_2", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-008612" } ] }, "cve": "CVE-2020-7592", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2020-7592", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 1.0, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-008612", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 6.1, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 6.5, "id": "CNVD-2020-40613", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:C/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-7592", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 6.5, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-008612", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-7592", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "JVNDB-2020-008612", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2020-40613", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202007-578", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-40613" }, { "db": "JVNDB", "id": "JVNDB-2020-008612" }, { "db": "CNNVD", "id": "CNNVD-202007-578" }, { "db": "NVD", "id": "CVE-2020-7592" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information. Several Siemens products contain vulnerabilities in the transmission of important information in clear text.Information may be obtained. SIMATIC HMI Panels are used for operator control, monitoring of machines and equipment. SIMATIC WinCC Runtime Advanced is a visual runtime platform, monitoring of machines and equipment. SIPLUS extreme products are designed to operate under extreme conditions. It is based on Imatic, LOGO! SITOP, SINAMICS, SIMOTION, SCALANCE or other equipment", "sources": [ { "db": "NVD", "id": "CVE-2020-7592" }, { "db": "JVNDB", "id": "JVNDB-2020-008612" }, { "db": "CNVD", "id": "CNVD-2020-40613" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-7592", "trust": 3.0 }, { "db": "ICS CERT", "id": "ICSA-20-196-04", "trust": 2.4 }, { "db": "SIEMENS", "id": "SSA-364335", "trust": 2.2 }, { "db": "JVN", "id": "JVNVU97872642", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2020-008612", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2020-40613", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2020.2387", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202007-578", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-40613" }, { "db": "JVNDB", "id": "JVNDB-2020-008612" }, { "db": "CNNVD", "id": "CNNVD-202007-578" }, { "db": "NVD", "id": "CVE-2020-7592" } ] }, "id": "VAR-202007-1238", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2020-40613" } ], "trust": 1.2365613500000001 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS", "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-40613" } ] }, "last_update_date": "2024-11-23T21:35:29.460000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-364335", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-364335.pdf" }, { "title": "Patch for Information Disclosure Vulnerabilities in Multiple Siemens Products", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/225825" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-40613" }, { "db": "JVNDB", "id": "JVNDB-2020-008612" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-319", "trust": 1.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-008612" }, { "db": "NVD", "id": "CVE-2020-7592" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-196-04" }, { "trust": 2.2, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-364335.pdf" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-7592" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7592" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu97872642/" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/simatic-information-disclosure-via-clear-text-transmission-32815" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2020.2387/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-40613" }, { "db": "JVNDB", "id": "JVNDB-2020-008612" }, { "db": "CNNVD", "id": "CNNVD-202007-578" }, { "db": "NVD", "id": "CVE-2020-7592" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2020-40613" }, { "db": "JVNDB", "id": "JVNDB-2020-008612" }, { "db": "CNNVD", "id": "CNNVD-202007-578" }, { "db": "NVD", "id": "CVE-2020-7592" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-07-17T00:00:00", "db": "CNVD", "id": "CNVD-2020-40613" }, { "date": "2020-09-17T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-008612" }, { "date": "2020-07-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202007-578" }, { "date": "2020-07-14T14:15:19.073000", "db": "NVD", "id": "CVE-2020-7592" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-07-17T00:00:00", "db": "CNVD", "id": "CNVD-2020-40613" }, { "date": "2020-09-17T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-008612" }, { "date": "2022-03-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202007-578" }, { "date": "2024-11-21T05:37:26.090000", "db": "NVD", "id": "CVE-2020-7592" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202007-578" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Vulnerability in plaintext transmission of critical information in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-008612" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202007-578" } ], "trust": 0.6 } }
var-201202-0048
Vulnerability from variot
Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allow user-assisted remote attackers to execute arbitrary code via a crafted project file, related to the HMI web server and runtime loader. plural Siemens The product includes HMI Web An arbitrary code execution vulnerability exists due to a flaw in processing related to the server and runtime loader.Crafted by attackers project An arbitrary code may be executed via the file. Siemens SIMATIC is an automation software in a single engineering environment. A security vulnerability exists in the Siemens SIMATIC WinCC HMI web server. Social engineering is required to enable administrators to download files and execute them. SIMATIC Wincc Runtime Advanced is prone to a remote security vulnerability. Vulnerabilities exist in several versions of Siemens SIMATIC WinCC
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0048", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "mp" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "op" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "tp" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.9, "vendor": "siemens", "version": "2008" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.9, "vendor": "siemens", "version": "2007" }, { "model": "wincc", "scope": "eq", "trust": 1.9, "vendor": "siemens", "version": "v11" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "comfort_panels" }, { "model": "wincc runtime advanced", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "v11" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "mobile_panels" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.4, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.4, "vendor": "siemens", "version": "2007" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.4, "vendor": "siemens", "version": "2005" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.4, "vendor": "siemens", "version": "2004" }, { "model": "simatic wincc", "scope": "eq", "trust": 1.4, "vendor": "siemens", "version": "v11" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.3, "vendor": "siemens", "version": "2005" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.3, "vendor": "siemens", "version": "2004" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.1, "vendor": "siemens", "version": "v11" }, { "model": "wincc flexible runtime", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "comfort panels" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "mobile panels" }, { "model": "simatic wincc flexible rumtime", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc flexible runtime", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic hmi panels", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "wincc flexible runtime", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "wincc flexible runtime", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi panels tp", "scope": null, "trust": 0.3, "vendor": "siemens", "version": null }, { "model": "simatic hmi panels op", "scope": null, "trust": 0.3, "vendor": "siemens", "version": null }, { "model": "simatic hmi panels mp", "scope": null, "trust": 0.3, "vendor": "siemens", "version": null }, { "model": "simatic hmi panels mobile panels", "scope": null, "trust": 0.3, "vendor": "siemens", "version": null }, { "model": "simatic hmi panels comfort panels", "scope": null, "trust": 0.3, "vendor": "siemens", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2004" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2005" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2007" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2008" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc", "version": "v11" }, { "model": "comfort panels", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "mobile panels", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "mp", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "op", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "tp", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc runtime advanced", "version": "v11" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible runtime", "version": "*" } ], "sources": [ { "db": "IVD", "id": "28dd62b0-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0463" }, { "db": "BID", "id": "78355" }, { "db": "JVNDB", "id": "JVNDB-2012-001315" }, { "db": "CNNVD", "id": "CNNVD-201202-088" }, { "db": "NVD", "id": "CVE-2011-4513" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:siemens:simatic_hmi_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_flexible", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_flexible_runtime", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2012-001315" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Unknown", "sources": [ { "db": "BID", "id": "78355" } ], "trust": 0.3 }, "cve": "CVE-2011-4513", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CVE-2011-4513", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "28dd62b0-2354-11e6-abef-000c29c66e3d", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "VHN-52458", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2011-4513", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2011-4513", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-201202-088", "trust": 0.6, "value": "CRITICAL" }, { "author": "IVD", "id": "28dd62b0-2354-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "CRITICAL" }, { "author": "VULHUB", "id": "VHN-52458", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "IVD", "id": "28dd62b0-2354-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-52458" }, { "db": "JVNDB", "id": "JVNDB-2012-001315" }, { "db": "CNNVD", "id": "CNNVD-201202-088" }, { "db": "NVD", "id": "CVE-2011-4513" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allow user-assisted remote attackers to execute arbitrary code via a crafted project file, related to the HMI web server and runtime loader. plural Siemens The product includes HMI Web An arbitrary code execution vulnerability exists due to a flaw in processing related to the server and runtime loader.Crafted by attackers project An arbitrary code may be executed via the file. Siemens SIMATIC is an automation software in a single engineering environment. A security vulnerability exists in the Siemens SIMATIC WinCC HMI web server. Social engineering is required to enable administrators to download files and execute them. SIMATIC Wincc Runtime Advanced is prone to a remote security vulnerability. Vulnerabilities exist in several versions of Siemens SIMATIC WinCC", "sources": [ { "db": "NVD", "id": "CVE-2011-4513" }, { "db": "JVNDB", "id": "JVNDB-2012-001315" }, { "db": "CNVD", "id": "CNVD-2012-0463" }, { "db": "BID", "id": "78355" }, { "db": "IVD", "id": "28dd62b0-2354-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-52458" } ], "trust": 2.7 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2011-4513", "trust": 3.6 }, { "db": "ICS CERT", "id": "ICSA-12-030-01", "trust": 3.4 }, { "db": "SIEMENS", "id": "SSA-345442", "trust": 2.0 }, { "db": "CNVD", "id": "CNVD-2012-0463", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201202-088", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2012-001315", "trust": 0.8 }, { "db": "BID", "id": "78355", "trust": 0.4 }, { "db": "IVD", "id": "28DD62B0-2354-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-52458", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "28dd62b0-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0463" }, { "db": "VULHUB", "id": "VHN-52458" }, { "db": "BID", "id": "78355" }, { "db": "JVNDB", "id": "JVNDB-2012-001315" }, { "db": "CNNVD", "id": "CNNVD-201202-088" }, { "db": "NVD", "id": "CVE-2011-4513" } ] }, "id": "VAR-201202-0048", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "28dd62b0-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0463" }, { "db": "VULHUB", "id": "VHN-52458" } ], "trust": 1.5188906333333334 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "28dd62b0-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0463" } ] }, "last_update_date": "2024-11-23T21:46:29.376000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-345442", "trust": 0.8, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "title": "\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc", "trust": 0.8, "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx" }, { "title": "Top Page", "trust": 0.8, "url": "http://www.siemens.com/entry/jp/ja/" }, { "title": "Patch for Siemens SIMATIC WinCC HMI Vulnerability (CNVD-2012-0463)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/9061" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2012-0463" }, { "db": "JVNDB", "id": "JVNDB-2012-001315" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2011-4513" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.4, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01.pdf" }, { "trust": 2.0, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4513" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4513" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2012-0463" }, { "db": "VULHUB", "id": "VHN-52458" }, { "db": "BID", "id": "78355" }, { "db": "JVNDB", "id": "JVNDB-2012-001315" }, { "db": "CNNVD", "id": "CNNVD-201202-088" }, { "db": "NVD", "id": "CVE-2011-4513" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "28dd62b0-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0463" }, { "db": "VULHUB", "id": "VHN-52458" }, { "db": "BID", "id": "78355" }, { "db": "JVNDB", "id": "JVNDB-2012-001315" }, { "db": "CNNVD", "id": "CNNVD-201202-088" }, { "db": "NVD", "id": "CVE-2011-4513" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2012-02-07T00:00:00", "db": "IVD", "id": "28dd62b0-2354-11e6-abef-000c29c66e3d" }, { "date": "2012-02-07T00:00:00", "db": "CNVD", "id": "CNVD-2012-0463" }, { "date": "2012-02-03T00:00:00", "db": "VULHUB", "id": "VHN-52458" }, { "date": "2012-02-03T00:00:00", "db": "BID", "id": "78355" }, { "date": "2012-02-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001315" }, { "date": "2012-02-07T00:00:00", "db": "CNNVD", "id": "CNNVD-201202-088" }, { "date": "2012-02-03T20:55:01.513000", "db": "NVD", "id": "CVE-2011-4513" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2012-02-07T00:00:00", "db": "CNVD", "id": "CNVD-2012-0463" }, { "date": "2012-02-06T00:00:00", "db": "VULHUB", "id": "VHN-52458" }, { "date": "2012-02-03T00:00:00", "db": "BID", "id": "78355" }, { "date": "2012-02-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001315" }, { "date": "2012-02-13T00:00:00", "db": "CNNVD", "id": "CNNVD-201202-088" }, { "date": "2024-11-21T01:32:27.357000", "db": "NVD", "id": "CVE-2011-4513" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201202-088" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Siemens Vulnerabilities in products that allow arbitrary code execution", "sources": [ { "db": "JVNDB", "id": "JVNDB-2012-001315" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "lack of information", "sources": [ { "db": "CNNVD", "id": "CNNVD-201202-088" } ], "trust": 0.6 } }
var-201202-0164
Vulnerability from variot
HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cause a denial of service (application crash) by sending crafted data over TCP. Miniweb has a security vulnerability that allows an attacker to submit a specially crafted HTTP POST request to allow the server to access any illegal memory area while checking the extension of the requested file. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. HmiLoad provides functions that read data and unicode strings with stack-based buffer overflows, allowing an attacker to exploit a vulnerability to execute arbitrary code. Siemens SIMATIC is an automation software in a single engineering environment. A security vulnerability exists in the Siemens SIMATIC WinCC HMI web server. When the transfer mode is enabled, the runtime loader listens on the 2308/TCP or 50523/TCP port. Since the incoming data is not fully verified, there are multiple denial of service attacks that can crash the program. A directory traversal vulnerability exists in the HmiLoad server that allows reading, writing, and deleting arbitrary files outside of the specified directory. Attackers can exploit these issues to execute arbitrary code in the context of the affected application, read/write or delete arbitrary files outside of the server root directory, or cause denial-of-service conditions; other attacks may also be possible
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0164", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic wincc flexible runtime", "scope": null, "trust": 3.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc flexible sp2", "scope": "eq", "trust": 3.3, "vendor": "siemens", "version": "2008" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "mp" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "op" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "tp" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2007" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2005" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2004" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "comfort_panels" }, { "model": "wincc runtime advanced", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "v11" }, { "model": "wincc", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "v11" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "2004" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "2005" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "mobile_panels" }, { "model": "simatic wincc", "scope": "eq", "trust": 1.4, "vendor": "siemens", "version": "v11" }, { "model": "wincc flexible runtime", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2007" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2008" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "comfort panels" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "mobile panels" }, { "model": "simatic wincc flexible rumtime", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "v11" }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic hmi panels", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "wincc flexible runtime", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc flexible runtime", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc flexible sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc flexible sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2005" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2004" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2005" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2007" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2008" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc", "version": "v11" }, { "model": "comfort panels", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "mobile panels", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "mp", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "op", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "tp", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc runtime advanced", "version": "v11" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible runtime", "version": "*" } ], "sources": [ { "db": "IVD", "id": "28b0bc2e-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2012-0467" }, { "db": "CNVD", "id": "CNVD-2011-5105" }, { "db": "BID", "id": "50828" }, { "db": "JVNDB", "id": "JVNDB-2012-001319" }, { "db": "CNNVD", "id": "CNNVD-201202-092" }, { "db": "NVD", "id": "CVE-2011-4877" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:siemens:simatic_hmi_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_flexible", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_flexible_runtime", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2012-001319" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Luigi Auriemma", "sources": [ { "db": "BID", "id": "50828" }, { "db": "CNNVD", "id": "CNNVD-201111-480" } ], "trust": 0.9 }, "cve": "CVE-2011-4877", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.1, "confidentialityImpact": "NONE", "exploitabilityScore": 8.6, "id": "CVE-2011-4877", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 7.1, "confidentialityImpact": "NONE", "exploitabilityScore": 8.6, "id": "28b0bc2e-2354-11e6-abef-000c29c66e3d", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 7.1, "confidentialityImpact": "NONE", "exploitabilityScore": 8.6, "id": "VHN-52822", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:M/AU:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2011-4877", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2011-4877", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-201202-092", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "28b0bc2e-2354-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-52822", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "IVD", "id": "28b0bc2e-2354-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-52822" }, { "db": "JVNDB", "id": "JVNDB-2012-001319" }, { "db": "CNNVD", "id": "CNNVD-201202-092" }, { "db": "NVD", "id": "CVE-2011-4877" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cause a denial of service (application crash) by sending crafted data over TCP. Miniweb has a security vulnerability that allows an attacker to submit a specially crafted HTTP POST request to allow the server to access any illegal memory area while checking the extension of the requested file. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. HmiLoad provides functions that read data and unicode strings with stack-based buffer overflows, allowing an attacker to exploit a vulnerability to execute arbitrary code. Siemens SIMATIC is an automation software in a single engineering environment. A security vulnerability exists in the Siemens SIMATIC WinCC HMI web server. When the transfer mode is enabled, the runtime loader listens on the 2308/TCP or 50523/TCP port. Since the incoming data is not fully verified, there are multiple denial of service attacks that can crash the program. A directory traversal vulnerability exists in the HmiLoad server that allows reading, writing, and deleting arbitrary files outside of the specified directory. \nAttackers can exploit these issues to execute arbitrary code in the context of the affected application, read/write or delete arbitrary files outside of the server root directory, or cause denial-of-service conditions; other attacks may also be possible", "sources": [ { "db": "NVD", "id": "CVE-2011-4877" }, { "db": "JVNDB", "id": "JVNDB-2012-001319" }, { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2012-0467" }, { "db": "CNVD", "id": "CNVD-2011-5105" }, { "db": "BID", "id": "50828" }, { "db": "IVD", "id": "28b0bc2e-2354-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-52822" } ], "trust": 5.4 }, "exploit_availability": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/exploit_availability#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "reference": "https://www.scap.org.cn/vuln/vhn-52822", "trust": 0.1, "type": "unknown" } ], "sources": [ { "db": "VULHUB", "id": "VHN-52822" } ] }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "BID", "id": "50828", "trust": 3.9 }, { "db": "NVD", "id": "CVE-2011-4877", "trust": 3.6 }, { "db": "ICS CERT", "id": "ICSA-12-030-01", "trust": 3.4 }, { "db": "SIEMENS", "id": "SSA-345442", "trust": 1.7 }, { "db": "ICS CERT ALERT", "id": "ICS-ALERT-11-332-02A", "trust": 1.1 }, { "db": "ICS CERT ALERT", "id": "ICS-ALERT-11-332-02", "trust": 1.1 }, { "db": "EXPLOIT-DB", "id": "18166", "trust": 1.1 }, { "db": "OSVDB", "id": "77382", "trust": 1.1 }, { "db": "CNNVD", "id": "CNNVD-201202-092", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2012-0467", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2012-001319", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2011-5108", "trust": 0.6 }, { "db": "CNVD", "id": "CNVD-2011-5110", "trust": 0.6 }, { "db": "CNVD", "id": "CNVD-2011-5103", "trust": 0.6 }, { "db": "CNVD", "id": "CNVD-2011-5107", "trust": 0.6 }, { "db": "CNVD", "id": "CNVD-2011-5105", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-201111-480", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-12-030-01A", "trust": 0.3 }, { "db": "IVD", "id": "28B0BC2E-2354-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-52822", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "28b0bc2e-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2012-0467" }, { "db": "CNVD", "id": "CNVD-2011-5105" }, { "db": "VULHUB", "id": "VHN-52822" }, { "db": "BID", "id": "50828" }, { "db": "JVNDB", "id": "JVNDB-2012-001319" }, { "db": "CNNVD", "id": "CNNVD-201111-480" }, { "db": "CNNVD", "id": "CNNVD-201202-092" }, { "db": "NVD", "id": "CVE-2011-4877" } ] }, "id": "VAR-201202-0164", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "28b0bc2e-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2012-0467" }, { "db": "CNVD", "id": "CNVD-2011-5105" }, { "db": "VULHUB", "id": "VHN-52822" } ], "trust": 4.568457485714285 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 3.8 } ], "sources": [ { "db": "IVD", "id": "28b0bc2e-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2012-0467" }, { "db": "CNVD", "id": "CNVD-2011-5105" } ] }, "last_update_date": "2024-11-23T21:46:29.545000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-345442", "trust": 0.8, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "title": "\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc", "trust": 0.8, "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx" }, { "title": "Top Page", "trust": 0.8, "url": "http://www.siemens.com/entry/jp/ja/" }, { "title": "Patch for Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 file download vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/72694" }, { "title": "Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 memory access vulnerability patch", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/72697" }, { "title": "Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 Buffer Overflow Vulnerability Patch", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/72705" }, { "title": "Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 service crash vulnerability patch", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/72689" }, { "title": "Patch for Siemens SIMATIC WinCC HMI Denial of Service Attack Vulnerability (CNVD-2012-0467)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/9073" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2012-0467" }, { "db": "JVNDB", "id": "JVNDB-2012-001319" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-20", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-52822" }, { "db": "JVNDB", "id": "JVNDB-2012-001319" }, { "db": "NVD", "id": "CVE-2011-4877" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.9, "url": "http://aluigi.altervista.org/adv/winccflex_1-adv.txt" }, { "trust": 3.4, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01.pdf" }, { "trust": 1.7, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "trust": 1.1, "url": "http://www.exploit-db.com/exploits/18166" }, { "trust": 1.1, "url": "http://aluigi.org/adv/winccflex_1-adv.txt" }, { "trust": 1.1, "url": "http://www.us-cert.gov/control_systems/pdf/ics-alert-11-332-02.pdf" }, { "trust": 1.1, "url": "http://www.us-cert.gov/control_systems/pdf/ics-alert-11-332-02a.pdf" }, { "trust": 1.1, "url": "http://www.osvdb.org/77382" }, { "trust": 1.1, "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71451" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4877" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4877" }, { "trust": 0.6, "url": "http://www.securityfocus.com/bid/50828" }, { "trust": 0.3, "url": "http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/wincc-flexible/wincc-flexible-runtime/pages/default.aspx" }, { "trust": 0.3, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01a.pdf" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2012-0467" }, { "db": "CNVD", "id": "CNVD-2011-5105" }, { "db": "VULHUB", "id": "VHN-52822" }, { "db": "BID", "id": "50828" }, { "db": "JVNDB", "id": "JVNDB-2012-001319" }, { "db": "CNNVD", "id": "CNNVD-201111-480" }, { "db": "CNNVD", "id": "CNNVD-201202-092" }, { "db": "NVD", "id": "CVE-2011-4877" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "28b0bc2e-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2012-0467" }, { "db": "CNVD", "id": "CNVD-2011-5105" }, { "db": "VULHUB", "id": "VHN-52822" }, { "db": "BID", "id": "50828" }, { "db": "JVNDB", "id": "JVNDB-2012-001319" }, { "db": "CNNVD", "id": "CNNVD-201111-480" }, { "db": "CNNVD", "id": "CNNVD-201202-092" }, { "db": "NVD", "id": "CVE-2011-4877" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2012-02-07T00:00:00", "db": "IVD", "id": "28b0bc2e-2354-11e6-abef-000c29c66e3d" }, { "date": "2011-12-05T00:00:00", "db": "CNVD", "id": "CNVD-2011-5108" }, { "date": "2011-12-05T00:00:00", "db": "CNVD", "id": "CNVD-2011-5110" }, { "date": "2011-12-05T00:00:00", "db": "CNVD", "id": "CNVD-2011-5103" }, { "date": "2011-12-05T00:00:00", "db": "CNVD", "id": "CNVD-2011-5107" }, { "date": "2012-02-07T00:00:00", "db": "CNVD", "id": "CNVD-2012-0467" }, { "date": "2011-12-05T00:00:00", "db": "CNVD", "id": "CNVD-2011-5105" }, { "date": "2012-02-03T00:00:00", "db": "VULHUB", "id": "VHN-52822" }, { "date": "2011-11-28T00:00:00", "db": "BID", "id": "50828" }, { "date": "2012-02-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001319" }, { "date": "1900-01-01T00:00:00", "db": "CNNVD", "id": "CNNVD-201111-480" }, { "date": "2012-02-07T00:00:00", "db": "CNNVD", "id": "CNNVD-201202-092" }, { "date": "2012-02-03T20:55:01.983000", "db": "NVD", "id": "CVE-2011-4877" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2016-03-15T00:00:00", "db": "CNVD", "id": "CNVD-2011-5108" }, { "date": "2016-03-15T00:00:00", "db": "CNVD", "id": "CNVD-2011-5110" }, { "date": "2016-03-15T00:00:00", "db": "CNVD", "id": "CNVD-2011-5103" }, { "date": "2016-03-15T00:00:00", "db": "CNVD", "id": "CNVD-2011-5107" }, { "date": "2012-02-07T00:00:00", "db": "CNVD", "id": "CNVD-2012-0467" }, { "date": "2011-12-05T00:00:00", "db": "CNVD", "id": "CNVD-2011-5105" }, { "date": "2017-08-29T00:00:00", "db": "VULHUB", "id": "VHN-52822" }, { "date": "2012-04-18T21:20:00", "db": "BID", "id": "50828" }, { "date": "2012-02-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001319" }, { "date": "2011-11-30T00:00:00", "db": "CNNVD", "id": "CNNVD-201111-480" }, { "date": "2012-02-07T00:00:00", "db": "CNNVD", "id": "CNNVD-201202-092" }, { "date": "2024-11-21T01:33:11.390000", "db": "NVD", "id": "CVE-2011-4877" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201111-480" }, { "db": "CNNVD", "id": "CNNVD-201202-092" } ], "trust": 1.2 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Siemens Product HmiLoad Service disruption in ( Application crash ) Vulnerabilities", "sources": [ { "db": "JVNDB", "id": "JVNDB-2012-001319" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Input validation", "sources": [ { "db": "IVD", "id": "28b0bc2e-2354-11e6-abef-000c29c66e3d" }, { "db": "CNNVD", "id": "CNNVD-201202-092" } ], "trust": 0.8 } }
var-202105-0791
Vulnerability from variot
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition. Multiple Siemens products are vulnerable to handling exceptional conditions.Denial of service (DoS) It may be put into a state. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202105-0791", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic wincc runtime advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic wincc runtime advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi comfort outdoor panels 7\"", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi comfort outdoor panels 15\"", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi comfort panels 4\"", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi comfort panels 22\"", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006945" }, { "db": "NVD", "id": "CVE-2021-25662" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-545" } ], "trust": 0.6 }, "cve": "CVE-2021-25662", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2021-25662", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2021-25662", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-25662", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-25662", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2021-25662", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202105-545", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-25662", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-25662" }, { "db": "JVNDB", "id": "JVNDB-2021-006945" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-545" }, { "db": "NVD", "id": "CVE-2021-25662" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition. Multiple Siemens products are vulnerable to handling exceptional conditions.Denial of service (DoS) It may be put into a state. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements", "sources": [ { "db": "NVD", "id": "CVE-2021-25662" }, { "db": "JVNDB", "id": "JVNDB-2021-006945" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULMON", "id": "CVE-2021-25662" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-25662", "trust": 3.3 }, { "db": "ICS CERT", "id": "ICSA-21-131-12", "trust": 2.5 }, { "db": "SIEMENS", "id": "SSA-538778", "trust": 1.7 }, { "db": "JVN", "id": "JVNVU91051134", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-006945", "trust": 0.8 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021051206", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202105-545", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-25662", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-25662" }, { "db": "JVNDB", "id": "JVNDB-2021-006945" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-545" }, { "db": "NVD", "id": "CVE-2021-25662" } ] }, "id": "VAR-202105-0791", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.465033575 }, "last_update_date": "2024-08-14T12:28:55.760000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-538778", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "title": "Siemens SmartVNC Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=151558" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=9465a8ef1f8c1b0042244cb02cfe271e" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-25662" }, { "db": "JVNDB", "id": "JVNDB-2021-006945" }, { "db": "CNNVD", "id": "CNNVD-202105-545" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-755", "trust": 1.0 }, { "problemtype": "Improper handling in exceptional conditions (CWE-755) [ Other ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006945" }, { "db": "NVD", "id": "CVE-2021-25662" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu91051134/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-25662" }, { "trust": 0.8, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-131-12" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021051206" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/smartvnc-multiple-vulnerabilities-35360" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/755.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://cert-portal.siemens.com/productcert/txt/ssa-538778.txt" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-25662" }, { "db": "JVNDB", "id": "JVNDB-2021-006945" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-545" }, { "db": "NVD", "id": "CVE-2021-25662" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-25662" }, { "db": "JVNDB", "id": "JVNDB-2021-006945" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-545" }, { "db": "NVD", "id": "CVE-2021-25662" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-05-12T00:00:00", "db": "VULMON", "id": "CVE-2021-25662" }, { "date": "2022-01-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-006945" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-05-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-545" }, { "date": "2021-05-12T14:15:11.343000", "db": "NVD", "id": "CVE-2021-25662" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-05-21T00:00:00", "db": "VULMON", "id": "CVE-2021-25662" }, { "date": "2022-01-26T07:30:00", "db": "JVNDB", "id": "JVNDB-2021-006945" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-10-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-545" }, { "date": "2021-12-16T18:26:19.067000", "db": "NVD", "id": "CVE-2021-25662" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-545" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Vulnerability in handling exceptional conditions in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006945" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-545" } ], "trust": 1.2 } }
var-202409-0272
Vulnerability from variot
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-7 LTE (All versions < V3.5.20), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.5.20), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC WinCC Runtime Advanced (All versions), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.4.8). The web server of the affected devices do not properly handle the shutdown or reboot request, which could lead to the clean up of certain resources.
This could allow a remote attacker with elevated privileges to cause a denial of service condition in the system. SIMATIC CP 1242 and CP 1243 related processors connect SIMATIC S7-1200 controllers to wide area networks (WANs). They offer integrated security features such as firewalls, virtual private networks (VPNs) and support for other data encryption protocols. SIMATIC HMI Panels are used for operator control and monitoring of machines and plants. SIMATIC IPC DiagBase diagnostics software allows early identification of any potential faults on SIMATIC industrial computers and helps to avoid or reduce system downtime. SIMATIC IPC DiagMonitor monitors, reports, visualizes and logs the system status of SIMATIC IPCs. It communicates with other systems and reacts when events occur. Communication processor (CP) modules SIMATIC TIM 3V-IE and TIM 4R-IE are designed to enable Ethernet or telecontrol communication for SIMATIC S7-300/S7-400 CPUs. SIMATIC WinCC Runtime Advanced is a visualization runtime platform for operator control and monitoring of machines and plants. SIPLUS extreme products are designed for reliable operation under extreme conditions and are based on SIMATIC, LOGO!, SITOP, SINAMICS, SIMOTION, SCALANCE or other devices. SIPLUS devices use the same firmware as the products they are based on.
Siemens Industrial products have a null pointer dereference vulnerability
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202409-0272", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic ipc diagmonitor", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "siplus tim irc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1531" }, { "model": "simatic ipc diagbase", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "tim irc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1531\u003cv2.4.8" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1242-7v2\u003cv3.5.20" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1243-1\u003cv3.5.20" }, { "model": "simatic cp dnp3", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1243-1\u003cv3.5.20" }, { "model": "simatic cp iec", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1243-1\u003cv3.5.20" }, { "model": "simatic cp lte", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1243-7\u003cv3.5.20" }, { "model": "simatic cp irc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1243-8\u003cv3.5.20" }, { "model": "simatic hmi comfort panels", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-38016" } ] }, "cve": "CVE-2023-30755", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "HIGH", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 5.4, "confidentialityImpact": "NONE", "exploitabilityScore": 4.9, "id": "CNVD-2024-38016", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:H/Au:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "HIGH", "attackVector": "NETWORK", "author": "productcert@siemens.com", "availabilityImpact": "HIGH", "baseScore": 4.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 0.7, "id": "CVE-2023-30755", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } ], "severity": [ { "author": "productcert@siemens.com", "id": "CVE-2023-30755", "trust": 1.0, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2024-38016", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-38016" }, { "db": "NVD", "id": "CVE-2023-30755" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions \u003c V3.5.20), SIMATIC CP 1243-7 LTE (All versions \u003c V3.5.20), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions \u003c V3.5.20), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC WinCC Runtime Advanced (All versions), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions \u003c V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions \u003c V2.4.8). The web server of the affected devices do not properly handle the shutdown or reboot request, which could lead to the clean up of certain resources. \r\n\r\nThis could allow a remote attacker with elevated privileges to cause a denial of service condition in the system. SIMATIC CP 1242 and CP 1243 related processors connect SIMATIC S7-1200 controllers to wide area networks (WANs). They offer integrated security features such as firewalls, virtual private networks (VPNs) and support for other data encryption protocols. SIMATIC HMI Panels are used for operator control and monitoring of machines and plants. SIMATIC IPC DiagBase diagnostics software allows early identification of any potential faults on SIMATIC industrial computers and helps to avoid or reduce system downtime. SIMATIC IPC DiagMonitor monitors, reports, visualizes and logs the system status of SIMATIC IPCs. It communicates with other systems and reacts when events occur. Communication processor (CP) modules SIMATIC TIM 3V-IE and TIM 4R-IE are designed to enable Ethernet or telecontrol communication for SIMATIC S7-300/S7-400 CPUs. SIMATIC WinCC Runtime Advanced is a visualization runtime platform for operator control and monitoring of machines and plants. SIPLUS extreme products are designed for reliable operation under extreme conditions and are based on SIMATIC, LOGO!, SITOP, SINAMICS, SIMOTION, SCALANCE or other devices. SIPLUS devices use the same firmware as the products they are based on. \n\nSiemens Industrial products have a null pointer dereference vulnerability", "sources": [ { "db": "NVD", "id": "CVE-2023-30755" }, { "db": "CNVD", "id": "CNVD-2024-38016" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "SIEMENS", "id": "SSA-423808", "trust": 1.6 }, { "db": "NVD", "id": "CVE-2023-30755", "trust": 1.6 }, { "db": "CNVD", "id": "CNVD-2024-38016", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-38016" }, { "db": "NVD", "id": "CVE-2023-30755" } ] }, "id": "VAR-202409-0272", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-38016" } ], "trust": 1.364781105 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-38016" } ] }, "last_update_date": "2024-09-13T23:28:46.308000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens Industrial Products Null Pointer Dereference Vulnerability (CNVD-2024-38016)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/590306" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-38016" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-476", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2023-30755" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-423808.html" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-38016" }, { "db": "NVD", "id": "CVE-2023-30755" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-38016" }, { "db": "NVD", "id": "CVE-2023-30755" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-09-12T00:00:00", "db": "CNVD", "id": "CNVD-2024-38016" }, { "date": "2024-09-10T10:15:05.940000", "db": "NVD", "id": "CVE-2023-30755" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-09-12T00:00:00", "db": "CNVD", "id": "CNVD-2024-38016" }, { "date": "2024-09-10T12:09:50.377000", "db": "NVD", "id": "CVE-2023-30755" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens Industrial Products Null Pointer Dereference Vulnerability (CNVD-2024-38016)", "sources": [ { "db": "CNVD", "id": "CNVD-2024-38016" } ], "trust": 0.6 } }
var-201202-0045
Vulnerability from variot
Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4511. plural Siemens Product HMI Web The server contains a cross-site scripting vulnerability. This vulnerability CVE-2011-4511 Is a different vulnerability.By any third party Web Script or HTML May be inserted. Siemens SIMATIC is an automation software in a single engineering environment. The SIMATIC HMI Smart Options web server has two separate cross-site scripting attacks that allow elevation of privilege, stealing data or corrupting services. SIMATIC HMI is prone to multiple unspecified cross-site scripting vulnerabilities because it fails to properly sanitize user-supplied input. An attacker may leverage these issues to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This can allow the attacker to steal cookie-based authentication credentials and launch other attacks
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0045", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "mp" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "op" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "tp" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "comfort_panels" }, { "model": "wincc runtime advanced", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "v11" }, { "model": "wincc", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "v11" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "mobile_panels" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.4, "vendor": "siemens", "version": "2007" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.4, "vendor": "siemens", "version": "2005" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.4, "vendor": "siemens", "version": "2004" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2004" }, { "model": "wincc flexible runtime", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2007" }, { "model": "wincc", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "v11" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2005" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2008" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "comfort panels" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "mobile panels" }, { "model": "simatic wincc", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "v11 sp2 update 1" }, { "model": "simatic wincc flexible", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "2008 sp3" }, { "model": "simatic wincc flexible rumtime", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "v11" }, { "model": null, "scope": "eq", "trust": 0.6, "vendor": "wincc flexible", "version": "2008" }, { "model": "simatic wincc flexible runtime", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "2008" }, { "model": "simatic hmi panels", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v11" }, { "model": "wincc flexible runtime", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "wincc", "version": "v11" }, { "model": "simatic hmi smart options", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2004" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2005" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2007" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc", "version": "*" }, { "model": "comfort panels", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "mobile panels", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "mp", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "op", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "tp", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc runtime advanced", "version": "v11" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible runtime", "version": "*" } ], "sources": [ { "db": "IVD", "id": "28691284-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0460" }, { "db": "BID", "id": "51835" }, { "db": "JVNDB", "id": "JVNDB-2012-001312" }, { "db": "CNNVD", "id": "CNNVD-201202-085" }, { "db": "NVD", "id": "CVE-2011-4510" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:siemens:simatic_hmi_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_flexible", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_flexible_runtime", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2012-001312" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Billy Rios, Terry McCorkle, Shawn Merdinger, and Luigi Auriemma.", "sources": [ { "db": "BID", "id": "51835" } ], "trust": 0.3 }, "cve": "CVE-2011-4510", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "exploitabilityScore": 8.6, "id": "CVE-2011-4510", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "exploitabilityScore": 8.6, "id": "28691284-2354-11e6-abef-000c29c66e3d", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.2, "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.9 [IVD]" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "exploitabilityScore": 8.6, "id": "VHN-52455", "impactScore": 2.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:M/AU:N/C:N/I:P/A:N", "version": "2.0" } ], "cvssV3": [], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2011-4510", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2011-4510", "trust": 0.8, "value": "Medium" }, { "author": "CNNVD", "id": "CNNVD-201202-085", "trust": 0.6, "value": "MEDIUM" }, { "author": "IVD", "id": "28691284-2354-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "MEDIUM" }, { "author": "VULHUB", "id": "VHN-52455", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "IVD", "id": "28691284-2354-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-52455" }, { "db": "JVNDB", "id": "JVNDB-2012-001312" }, { "db": "CNNVD", "id": "CNNVD-201202-085" }, { "db": "NVD", "id": "CVE-2011-4510" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4511. plural Siemens Product HMI Web The server contains a cross-site scripting vulnerability. This vulnerability CVE-2011-4511 Is a different vulnerability.By any third party Web Script or HTML May be inserted. Siemens SIMATIC is an automation software in a single engineering environment. The SIMATIC HMI Smart Options web server has two separate cross-site scripting attacks that allow elevation of privilege, stealing data or corrupting services. SIMATIC HMI is prone to multiple unspecified cross-site scripting vulnerabilities because it fails to properly sanitize user-supplied input. \nAn attacker may leverage these issues to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This can allow the attacker to steal cookie-based authentication credentials and launch other attacks", "sources": [ { "db": "NVD", "id": "CVE-2011-4510" }, { "db": "JVNDB", "id": "JVNDB-2012-001312" }, { "db": "CNVD", "id": "CNVD-2012-0460" }, { "db": "BID", "id": "51835" }, { "db": "IVD", "id": "28691284-2354-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-52455" } ], "trust": 2.7 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2011-4510", "trust": 3.6 }, { "db": "ICS CERT", "id": "ICSA-12-030-01", "trust": 3.4 }, { "db": "SIEMENS", "id": "SSA-345442", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-201202-085", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2012-0460", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2012-001312", "trust": 0.8 }, { "db": "NSFOCUS", "id": "19403", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-12-030-01A", "trust": 0.3 }, { "db": "BID", "id": "51835", "trust": 0.3 }, { "db": "IVD", "id": "28691284-2354-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-52455", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "28691284-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0460" }, { "db": "VULHUB", "id": "VHN-52455" }, { "db": "BID", "id": "51835" }, { "db": "JVNDB", "id": "JVNDB-2012-001312" }, { "db": "CNNVD", "id": "CNNVD-201202-085" }, { "db": "NVD", "id": "CVE-2011-4510" } ] }, "id": "VAR-201202-0045", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "28691284-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0460" }, { "db": "VULHUB", "id": "VHN-52455" } ], "trust": 1.52394115 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "28691284-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0460" } ] }, "last_update_date": "2024-11-23T21:46:29.499000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-345442", "trust": 0.8, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "title": "\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc", "trust": 0.8, "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx" }, { "title": "Top Page", "trust": 0.8, "url": "http://www.siemens.com/entry/jp/ja/" }, { "title": "Patch for Siemens SIMATIC WinCC HMI Cross-Site Scripting Vulnerability (CNVD-2012-0460)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/9058" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2012-0460" }, { "db": "JVNDB", "id": "JVNDB-2012-001312" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-79", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-52455" }, { "db": "JVNDB", "id": "JVNDB-2012-001312" }, { "db": "NVD", "id": "CVE-2011-4510" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.4, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01.pdf" }, { "trust": 1.7, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4510" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4510" }, { "trust": 0.6, "url": "http://www.nsfocus.net/vulndb/19403" }, { "trust": 0.3, "url": "http://www.automation.siemens.com/mcms/automation/en/human-machine-interface/pages/default.aspx" }, { "trust": 0.3, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01a.pdf" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2012-0460" }, { "db": "VULHUB", "id": "VHN-52455" }, { "db": "BID", "id": "51835" }, { "db": "JVNDB", "id": "JVNDB-2012-001312" }, { "db": "CNNVD", "id": "CNNVD-201202-085" }, { "db": "NVD", "id": "CVE-2011-4510" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "28691284-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-0460" }, { "db": "VULHUB", "id": "VHN-52455" }, { "db": "BID", "id": "51835" }, { "db": "JVNDB", "id": "JVNDB-2012-001312" }, { "db": "CNNVD", "id": "CNNVD-201202-085" }, { "db": "NVD", "id": "CVE-2011-4510" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2012-02-07T00:00:00", "db": "IVD", "id": "28691284-2354-11e6-abef-000c29c66e3d" }, { "date": "2012-02-07T00:00:00", "db": "CNVD", "id": "CNVD-2012-0460" }, { "date": "2012-02-03T00:00:00", "db": "VULHUB", "id": "VHN-52455" }, { "date": "2012-01-30T00:00:00", "db": "BID", "id": "51835" }, { "date": "2012-02-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001312" }, { "date": "2012-02-07T00:00:00", "db": "CNNVD", "id": "CNNVD-201202-085" }, { "date": "2012-02-03T20:55:01.343000", "db": "NVD", "id": "CVE-2011-4510" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2012-02-07T00:00:00", "db": "CNVD", "id": "CNVD-2012-0460" }, { "date": "2012-02-06T00:00:00", "db": "VULHUB", "id": "VHN-52455" }, { "date": "2012-04-18T21:20:00", "db": "BID", "id": "51835" }, { "date": "2012-02-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001312" }, { "date": "2012-02-07T00:00:00", "db": "CNNVD", "id": "CNNVD-201202-085" }, { "date": "2024-11-21T01:32:27.010000", "db": "NVD", "id": "CVE-2011-4510" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201202-085" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Siemens Product HMI Web Server cross-site scripting vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2012-001312" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "XSS", "sources": [ { "db": "CNNVD", "id": "CNNVD-201202-085" } ], "trust": 0.6 } }
var-202105-0689
Vulnerability from variot
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition. Multiple Siemens products are vulnerable to resource allocation without restrictions or throttling.Denial of service (DoS) It may be put into a state. Siemens SmartVNC is an industrial control equipment of Germany's Siemens (Siemens) company. Provides a function to access the smartserver in the HMI.
SmartVNC has a buffer overflow vulnerability. No detailed vulnerability details are currently provided. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202105-0689", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics sl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinamics gm150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic wincc runtime advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinamics sm150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "sinamics sm150i", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic wincc runtime advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi comfort outdoor panels 15\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gh150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 4\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort outdoor panels 7\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics sm120", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic hmi comfort panels 22\\\"", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics sh150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics sh150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sl150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sm120", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sm150i", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic hmi comfort outdoor panels 7\"", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics gh150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics sm150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics gl150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinamics gm150", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "smartvnc", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37595" }, { "db": "JVNDB", "id": "JVNDB-2021-006948" }, { "db": "NVD", "id": "CVE-2021-27383" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-550" } ], "trust": 0.6 }, "cve": "CVE-2021-27383", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2021-27383", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2021-37595", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2021-27383", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-27383", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-27383", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2021-27383", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-37595", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202105-550", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-27383", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37595" }, { "db": "VULMON", "id": "CVE-2021-27383" }, { "db": "JVNDB", "id": "JVNDB-2021-006948" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-550" }, { "db": "NVD", "id": "CVE-2021-27383" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition. Multiple Siemens products are vulnerable to resource allocation without restrictions or throttling.Denial of service (DoS) It may be put into a state. Siemens SmartVNC is an industrial control equipment of Germany\u0027s Siemens (Siemens) company. Provides a function to access the smartserver in the HMI. \n\r\n\r\nSmartVNC has a buffer overflow vulnerability. No detailed vulnerability details are currently provided. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements", "sources": [ { "db": "NVD", "id": "CVE-2021-27383" }, { "db": "JVNDB", "id": "JVNDB-2021-006948" }, { "db": "CNVD", "id": "CNVD-2021-37595" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULMON", "id": "CVE-2021-27383" } ], "trust": 2.79 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-27383", "trust": 3.9 }, { "db": "ICS CERT", "id": "ICSA-21-131-12", "trust": 2.5 }, { "db": "SIEMENS", "id": "SSA-286838", "trust": 1.7 }, { "db": "SIEMENS", "id": "SSA-538778", "trust": 1.7 }, { "db": "JVN", "id": "JVNVU91051134", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-006948", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-37595", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021051206", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-21-131-04", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202105-550", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-27383", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37595" }, { "db": "VULMON", "id": "CVE-2021-27383" }, { "db": "JVNDB", "id": "JVNDB-2021-006948" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-550" }, { "db": "NVD", "id": "CVE-2021-27383" } ] }, "id": "VAR-202105-0689", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-37595" } ], "trust": 1.205898611111111 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37595" } ] }, "last_update_date": "2024-08-14T12:12:16.353000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-286838 Siemens\u00a0Security\u00a0Advisory", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "title": "Patch for Siemens SmartVNC buffer overflow vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/268266" }, { "title": "Siemens SmartVNC Buffer error vulnerability fix", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=151560" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=43c9c77785b8d29daef02185f41ca476" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=9465a8ef1f8c1b0042244cb02cfe271e" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37595" }, { "db": "VULMON", "id": "CVE-2021-27383" }, { "db": "JVNDB", "id": "JVNDB-2021-006948" }, { "db": "CNNVD", "id": "CNNVD-202105-550" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-770", "trust": 1.0 }, { "problemtype": "Allocation of resources without limits or throttling (CWE-770) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006948" }, { "db": "NVD", "id": "CVE-2021-27383" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-27383" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu91051134/" }, { "trust": 0.8, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-131-12" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021051206" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/smartvnc-multiple-vulnerabilities-35360" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/770.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://cert-portal.siemens.com/productcert/txt/ssa-286838.txt" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-37595" }, { "db": "VULMON", "id": "CVE-2021-27383" }, { "db": "JVNDB", "id": "JVNDB-2021-006948" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-550" }, { "db": "NVD", "id": "CVE-2021-27383" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-37595" }, { "db": "VULMON", "id": "CVE-2021-27383" }, { "db": "JVNDB", "id": "JVNDB-2021-006948" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202105-550" }, { "db": "NVD", "id": "CVE-2021-27383" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-05-28T00:00:00", "db": "CNVD", "id": "CNVD-2021-37595" }, { "date": "2021-05-12T00:00:00", "db": "VULMON", "id": "CVE-2021-27383" }, { "date": "2022-01-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-006948" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-05-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-550" }, { "date": "2021-05-12T14:15:11.633000", "db": "NVD", "id": "CVE-2021-27383" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-09-07T00:00:00", "db": "CNVD", "id": "CNVD-2021-37595" }, { "date": "2021-12-16T00:00:00", "db": "VULMON", "id": "CVE-2021-27383" }, { "date": "2022-01-26T07:30:00", "db": "JVNDB", "id": "JVNDB-2021-006948" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-10-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202105-550" }, { "date": "2021-12-16T18:29:27.357000", "db": "NVD", "id": "CVE-2021-27383" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202105-550" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Vulnerability in resource allocation without limits or throttling in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-006948" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-975" } ], "trust": 0.6 } }
var-202405-0210
Vulnerability from variot
A vulnerability has been identified in S7-PCT (All versions), Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions < V5.0 SP2), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions < V16 Update 8), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions < V18 SP1), SIMATIC NET PC Software V19 (All versions < V19 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PDM V9.2 (All versions < V9.2 SP2 Upd3), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 Upd3), SIMATIC STEP 7 V5 (All versions), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions < V3.18 P025), SIMATIC WinCC OA V3.19 (All versions < V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC Unified PC Runtime V18 (All versions), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5), SINAMICS Startdrive (All versions < V19 SP1), SINEC NMS (All versions < V3.0), SINEC NMS (All versions < V3.0 SP1), SINUMERIK ONE virtual (All versions < V6.23), SINUMERIK PLC Programming Tool (All versions < V3.3.12), TIA Portal Cloud Connector (All versions < V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 2). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel. S7 PCT (Port Configuration Tool) is a PC-based software for parameterizing Siemens IO-Link master modules and third-party IO-Link devices. Security Configuration Tool (SCT) is an engineering software for safety devices such as SCALANCE-S or CP 443-1Advanced. SIMATIC Automation Tool allows commissioning, adjustment and service in combination with S7-1200 and S7-1500 controllers without an engineering framework. SIMATIC NET PC software is a separately sold software product for implementing communication products for SIMATIC.NET. SIMATIC PCS 7 is a distributed control system (DCS) that integrates SIMATIC WinCC, SIMATIC Batch, SIMATIC Route control, OpenPCS 7 and other components. SIMATIC PDM (Process Device Manager) is a universal, manufacturer-independent tool for configuration, parameter assignment, commissioning, diagnostics and maintenance of intelligent process devices (actuators, sensors) and automation components (remote I/O, multiplexers, process control units, compact controllers). SIMATIC STEP 7 V5 is the classic engineering software for configuring and programming SIMATIC S7-300/S7-400/C7/WinAC controllers. SIMATIC WinCC is a Supervisory Control and Data Acquisition (SCADA) system. SIMATIC WinCC Open Architecture (OA) is part of the SIMATIC HMI family. It is designed for applications that require a high degree of customer-specific adaptability, large or complex applications, and projects that impose specific system requirements or functions. SIMATIC WinCC Runtime Advanced is a visualization runtime platform for operator control and monitoring of machines and plants. SIMATIC WinCC Runtime Professional is a visualization runtime platform for operator control and monitoring of machines and plants. SIMATIC WinCC Unified PC Runtime is a new visualization runtime platform for operator control and monitoring of machines and plants. SINAMICS Startdrive commissioning software is the engineering tool for integrating SINAMICS drives in the TIA Portal. SINUMERIK CNC provides automation solutions for workshops, shop floors and large serial production environments. SINUMERIK ONE is a digital native CNC system. Totally Integrated Automation Portal (TIA Portal) is a PC software that provides the complete range of Siemens digital automation services, from digital planning and integrated engineering to transparent operation. TIA Portal Cloud Connector enables access to local PG/PC interfaces and connected SIMATIC hardware from TIA Portal Engineering when engineering via remote desktop on a private cloud server
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202405-0210", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "security configuration tool", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic automation tool", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic net pc software", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc oa", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v3.17" }, { "model": "totally integrated automation portal", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v16" }, { "model": "totally integrated automation portal", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v17" }, { "model": "totally integrated automation portal", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v18" }, { "model": "totally integrated automation portal", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v15.1" }, { "model": "simatic pcs", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "7v9.1" }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v17" }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v18" }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v19" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v8.0" }, { "model": "totally integrated automation portal update", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v19\u003cv192" }, { "model": "tia portal cloud connector", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v2.0" }, { "model": "sinumerik plc programming tool", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinumerik one virtual", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v6.23" }, { "model": "sinamics startdrive sp1", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v19" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v7.5" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v7.4" }, { "model": "simatic wincc unified pc runtime", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v16" }, { "model": "simatic wincc oa p010", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v3.19\u003cv3.19" }, { "model": "simatic wincc oa p025", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v3.18\u003cv3.18" }, { "model": "simatic step", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "7v5" }, { "model": "simatic route control", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v9.1" }, { "model": "simatic pdm", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v9.2" }, { "model": "simatic batch", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v9.1" }, { "model": "s7-pct", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-24524" } ] }, "cve": "CVE-2023-46280", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 4.6, "confidentialityImpact": "NONE", "exploitabilityScore": 3.1, "id": "CNVD-2024-24524", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:L/AC:L/Au:S/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "productcert@siemens.com", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 2.0, "id": "CVE-2023-46280", "impactScore": 4.0, "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H", "version": "3.1" } ], "severity": [ { "author": "productcert@siemens.com", "id": "CVE-2023-46280", "trust": 1.0, "value": "High" }, { "author": "CNVD", "id": "CNVD-2024-24524", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-24524" }, { "db": "NVD", "id": "CVE-2023-46280" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in S7-PCT (All versions), Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions \u003c V5.0 SP2), SIMATIC BATCH V9.1 (All versions \u003c V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions \u003c V16 Update 8), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions \u003c V18 SP1), SIMATIC NET PC Software V19 (All versions \u003c V19 Update 2), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC PDM V9.2 (All versions \u003c V9.2 SP2 Upd3), SIMATIC Route Control V9.1 (All versions \u003c V9.1 SP2 Upd3), SIMATIC STEP 7 V5 (All versions), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions \u003c V3.18 P025), SIMATIC WinCC OA V3.19 (All versions \u003c V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions \u003c V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC Unified PC Runtime V18 (All versions), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 5), SINAMICS Startdrive (All versions \u003c V19 SP1), SINEC NMS (All versions \u003c V3.0), SINEC NMS (All versions \u003c V3.0 SP1), SINUMERIK ONE virtual (All versions \u003c V6.23), SINUMERIK PLC Programming Tool (All versions \u003c V3.3.12), TIA Portal Cloud Connector (All versions \u003c V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions \u003c V19 Update 2). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel. S7 PCT (Port Configuration Tool) is a PC-based software for parameterizing Siemens IO-Link master modules and third-party IO-Link devices. Security Configuration Tool (SCT) is an engineering software for safety devices such as SCALANCE-S or CP 443-1Advanced. SIMATIC Automation Tool allows commissioning, adjustment and service in combination with S7-1200 and S7-1500 controllers without an engineering framework. SIMATIC NET PC software is a separately sold software product for implementing communication products for SIMATIC.NET. SIMATIC PCS 7 is a distributed control system (DCS) that integrates SIMATIC WinCC, SIMATIC Batch, SIMATIC Route control, OpenPCS 7 and other components. SIMATIC PDM (Process Device Manager) is a universal, manufacturer-independent tool for configuration, parameter assignment, commissioning, diagnostics and maintenance of intelligent process devices (actuators, sensors) and automation components (remote I/O, multiplexers, process control units, compact controllers). SIMATIC STEP 7 V5 is the classic engineering software for configuring and programming SIMATIC S7-300/S7-400/C7/WinAC controllers. SIMATIC WinCC is a Supervisory Control and Data Acquisition (SCADA) system. SIMATIC WinCC Open Architecture (OA) is part of the SIMATIC HMI family. It is designed for applications that require a high degree of customer-specific adaptability, large or complex applications, and projects that impose specific system requirements or functions. SIMATIC WinCC Runtime Advanced is a visualization runtime platform for operator control and monitoring of machines and plants. SIMATIC WinCC Runtime Professional is a visualization runtime platform for operator control and monitoring of machines and plants. SIMATIC WinCC Unified PC Runtime is a new visualization runtime platform for operator control and monitoring of machines and plants. SINAMICS Startdrive commissioning software is the engineering tool for integrating SINAMICS drives in the TIA Portal. SINUMERIK CNC provides automation solutions for workshops, shop floors and large serial production environments. SINUMERIK ONE is a digital native CNC system. Totally Integrated Automation Portal (TIA Portal) is a PC software that provides the complete range of Siemens digital automation services, from digital planning and integrated engineering to transparent operation. TIA Portal Cloud Connector enables access to local PG/PC interfaces and connected SIMATIC hardware from TIA Portal Engineering when engineering via remote desktop on a private cloud server", "sources": [ { "db": "NVD", "id": "CVE-2023-46280" }, { "db": "CNVD", "id": "CNVD-2024-24524" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "SIEMENS", "id": "SSA-962515", "trust": 1.6 }, { "db": "NVD", "id": "CVE-2023-46280", "trust": 1.6 }, { "db": "SIEMENS", "id": "SSA-784301", "trust": 1.0 }, { "db": "SIEMENS", "id": "SSA-331112", "trust": 1.0 }, { "db": "CNVD", "id": "CNVD-2024-24524", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-24524" }, { "db": "NVD", "id": "CVE-2023-46280" } ] }, "id": "VAR-202405-0210", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-24524" } ], "trust": 1.2706952166666667 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-24524" } ] }, "last_update_date": "2024-11-13T19:49:07.316000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens Industrial Products Out-of-Bounds Read Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/547666" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-24524" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-125", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2023-46280" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-962515.html" }, { "trust": 1.0, "url": "https://cert-portal.siemens.com/productcert/html/ssa-331112.html" }, { "trust": 1.0, "url": "https://cert-portal.siemens.com/productcert/html/ssa-784301.html" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-24524" }, { "db": "NVD", "id": "CVE-2023-46280" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-24524" }, { "db": "NVD", "id": "CVE-2023-46280" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-30T00:00:00", "db": "CNVD", "id": "CNVD-2024-24524" }, { "date": "2024-05-14T16:15:40.800000", "db": "NVD", "id": "CVE-2023-46280" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-28T00:00:00", "db": "CNVD", "id": "CNVD-2024-24524" }, { "date": "2024-11-12T13:15:05.960000", "db": "NVD", "id": "CVE-2023-46280" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens Industrial Products Out-of-Bounds Read Vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2024-24524" } ], "trust": 0.6 } }
var-202211-0343
Vulnerability from variot
The login endpoint /FormLogin in affected web services does not apply proper origin checking.
This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack. simatic s7-1500 software controller , SIMATIC S7-PLCSIM Advanced , simatic wincc runtime A cross-site request forgery vulnerability exists in multiple Siemens products.Information may be obtained. SIMATIC Drive Controllers are designed for the automation of production machines, combining the functions of SIMATIC S7-1500 CPU and SINAMICS S120 drive control. SIMATIC PC Station is a software component for managing SIMATIC software products and interfaces on PCs. SIMATIC S7-1200 CPUs and SIMATIC S7-1500 CPUs have been designed for discrete and continuous control in industrial environments such as manufacturing, food and beverage, and the global chemical industry. SIMATIC S7-1500 Software Controller is a SIMATIC software controller for pc-based automation solutions. SIMATIC S7-300 controllers and SIMATIC S7-400 controllers have been designed for discrete and continuous control in industrial environments such as manufacturing, food and beverage, and the global chemical industry. SIMATIC S7-PLCSIM Advanced simulates S7-1200, S7-1500 and some other PLC derivatives. Includes full network access to simulated PLCs, even in virtual environments. SIMATIC WinAC RTX is a SIMATIC software controller for pc-based automation solutions. SIMATIC WinCC Runtime Advanced is a visualization runtime platform for operator control and monitoring of machines and plants. SINUMERIK ONE is a digitally native CNC with integrated SIMATIC S7-1500 CPU for automation. SIPLUS extreme products are designed for reliable operation under extreme conditions, based on SIMATIC, LOGO!, SITOP, SINAMICS, SIMOTION, SCALANCE or other devices. SIPLUS devices use the same firmware as the products on which they are based
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202211-0343", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic s7-1500 cpu 15pro-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1518hf-4", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1513f-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1510sp-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1200 cpu 12 1214fc", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1517f-3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1517tf-3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1513r-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1200 cpu 1215fc", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1516pro-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1200 cpu 1212c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1511f-1 pn", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1200 cpu 1214 fc", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-400 pn\\/dp v6", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "6es7317-2ek14-0ab0", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic s7-1500 cpu 1518-4 pn\\/dp mfp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1200 cpu 1212fc", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1510sp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1516-3 pn\\/dp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "6es7154-8fb01-0ab0", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic s7-1500 cpu 1511tf-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "6es7317-7tk10-0ab0", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.2.19" }, { "model": "6es7154-8ab01-0ab0", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic s7-1500 cpu 1518f-4", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "6ag1317-2ek14-7ab0", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.2.19" }, { "model": "6es7315-2eh14-0ab0", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic s7-1500 cpu 1518", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "6ag1314-6eh04-7ab0", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.19" }, { "model": "6ag1151-8fb01-2ab0", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic s7-1500 cpu 1516-3 pn", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1517f-3 pn\\/dp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1513-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1516f-3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "6ag1317-2fk14-2ab0", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic s7-1500 cpu 1516f-3 pn\\/dp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1200 cpu 12 1212c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1518tf-4", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1512sp-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "6es7151-8fb01-0ab0", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.2.19" }, { "model": "6es7318-3fl01-0ab0", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic s7-1500 cpu 1518-4 pn", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1518-4", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1516pro f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1516-3 dp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1515r-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 software controller", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "6ag1315-2fj14-2ab0", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic s7-1500 cpu 1515f-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "sinumerik one", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1200 cpu 1217c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1516t-3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1200 cpu 12 1217c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1511-1 pn", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "6es7154-8fx00-0ab0", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic s7-1500 cpu 1517-3 dp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic pcs", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "2.1" }, { "model": "6es7318-3el01-0ab0", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic s7-1500 cpu 1511-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1200 cpu 1211c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "6ag1315-2eh14-7ab0", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic s7-1200 cpu 1214fc", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1507s", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 15prof-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1515-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic drive controller cpu 1504d tf", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1200 cpu 1214c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "6es7317-7ul10-0ab0", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic s7-1500 cpu 1512c-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-400 pn\\/dp v7", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-plcsim advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1515tf-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu cpu 1513prof-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1200 cpu 12 1215fc", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1518f-4 pn\\/dp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1515t-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1511c-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1507s f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "6es7317-2fk14-0ab0", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic s7-1500 cpu 1511f-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1513f-1 pn", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "6ag1151-8ab01-7ab0", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic s7-1200 cpu 12 1211c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1508s", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1200 cpu 1215 fc", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1518-4 pn\\/dp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1200 cpu 1215c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1200 cpu 12 1215c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1513-1 pn", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1516tf-3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1508s f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "6es7314-6eh04-0ab0", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.19" }, { "model": "simatic s7-1500 cpu 1515-2 pn", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1517-3 pn", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1515f-2 pn", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1517-3 pn\\/dp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1518t-4", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 151511f-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "6es7151-8ab01-0ab0", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic drive controller cpu 1507d tf", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1200 cpu 12 1212fc", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "6es7315-2fj14-0ab0", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic s7-1500 cpu 1518-4 dp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1512c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1511t-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1512spf-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "6es7315-7tj10-0ab0", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic s7-1500 cpu cpu 1513pro-2", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 151511c-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1200 cpu 12 1214c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1516-3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1511c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu 1517-3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 software controller", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6es7317-2fk14-0ab0", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6es7154-8fb01-0ab0", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6ag1151-8ab01-7ab0", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6ag1151-8fb01-2ab0", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic wincc runtime", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6es7317-7ul10-0ab0", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6es7151-8ab01-0ab0", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic s7-plcsim advanced", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6es7315-7tj10-0ab0", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6es7318-3el01-0ab0", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6es7318-3fl01-0ab0", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6es7154-8fx00-0ab0", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6es7154-8ab01-0ab0", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6es7151-8fb01-0ab0", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6es7317-2ek14-0ab0", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6es7317-7tk10-0ab0", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6es7315-2eh14-0ab0", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6es7314-6eh04-0ab0", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "6es7315-2fj14-0ab0", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic s7-1500 software controller", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic s7-plcsim advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic drive controller family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic s7-1200 cpu family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinumerik one", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic et 200pro im154-8 pn/dp cpu", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic et 200pro im154-8f pn/dp cpu", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic et 200pro im154-8fx pn/dp cpu", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic et 200s im151-8 pn/dp cpu", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic et 200s im151-8f pn/dp cpu", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic pc station", "scope": "gte", "trust": 0.6, "vendor": "siemens", "version": "2.1" }, { "model": "simatic s7-300 cpu 314c-2 pn/dp", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "3.3.19" }, { "model": "simatic s7-300 cpu pn/dp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "315-2\u003c3.2.19" }, { "model": "simatic s7-300 cpu 315f-2 pn/dp", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic s7-300 cpu 315t-3 pn/dp", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic s7-300 cpu pn/dp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "317-2\u003c3.2.19" }, { "model": "simatic s7-300 cpu 317f-2 pn/dp", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic s7-300 cpu 317t-3 pn/dp", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic s7-300 cpu 317tf-3 pn/dp", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic s7-300 cpu pn/dp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "319-3\u003c3.2.19" }, { "model": "simatic s7-300 cpu 319f-3 pn/dp", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "3.2.19" }, { "model": "simatic s7-400 pn/dp cpu family", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v6" }, { "model": "simatic s7-400 pn/dp cpu family", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v7" }, { "model": "siplus et 200s im151-8 pn/dp cpu", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "3.2.19" }, { "model": "siplus et 200s im151-8f pn/dp cpu", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "3.2.19" }, { "model": "siplus s7-300 cpu 314c-2 pn/dp", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "3.3.19" }, { "model": "siplus s7-300 cpu pn/dp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "315-2\u003c3.2.19" }, { "model": "siplus s7-300 cpu 315f-2 pn/dp", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "3.2.19" }, { "model": "siplus s7-300 cpu pn/dp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "317-2\u003c3.2.19" }, { "model": "siplus s7-300 cpu 317f-2 pn/dp", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "3.2.19" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-75547" }, { "db": "JVNDB", "id": "JVNDB-2022-020602" }, { "db": "NVD", "id": "CVE-2022-30694" } ] }, "cve": "CVE-2022-30694", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 7.8, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2022-75547", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "productcert@siemens.com", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2022-30694", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 3.5, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "exploitabilityScore": 2.1, "id": "CVE-2022-30694", "impactScore": 1.4, "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "OTHER", "availabilityImpact": "None", "baseScore": 6.5, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2022-020602", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "productcert@siemens.com", "id": "CVE-2022-30694", "trust": 1.0, "value": "MEDIUM" }, { "author": "nvd@nist.gov", "id": "CVE-2022-30694", "trust": 1.0, "value": "LOW" }, { "author": "OTHER", "id": "JVNDB-2022-020602", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2022-75547", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202211-2266", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-75547" }, { "db": "JVNDB", "id": "JVNDB-2022-020602" }, { "db": "CNNVD", "id": "CNNVD-202211-2266" }, { "db": "NVD", "id": "CVE-2022-30694" }, { "db": "NVD", "id": "CVE-2022-30694" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "The login endpoint /FormLogin in affected web services does not apply proper origin checking. \r\n\r\nThis could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack. simatic s7-1500 software controller , SIMATIC S7-PLCSIM Advanced , simatic wincc runtime A cross-site request forgery vulnerability exists in multiple Siemens products.Information may be obtained. SIMATIC Drive Controllers are designed for the automation of production machines, combining the functions of SIMATIC S7-1500 CPU and SINAMICS S120 drive control. SIMATIC PC Station is a software component for managing SIMATIC software products and interfaces on PCs. SIMATIC S7-1200 CPUs and SIMATIC S7-1500 CPUs have been designed for discrete and continuous control in industrial environments such as manufacturing, food and beverage, and the global chemical industry. SIMATIC S7-1500 Software Controller is a SIMATIC software controller for pc-based automation solutions. SIMATIC S7-300 controllers and SIMATIC S7-400 controllers have been designed for discrete and continuous control in industrial environments such as manufacturing, food and beverage, and the global chemical industry. SIMATIC S7-PLCSIM Advanced simulates S7-1200, S7-1500 and some other PLC derivatives. Includes full network access to simulated PLCs, even in virtual environments. SIMATIC WinAC RTX is a SIMATIC software controller for pc-based automation solutions. SIMATIC WinCC Runtime Advanced is a visualization runtime platform for operator control and monitoring of machines and plants. SINUMERIK ONE is a digitally native CNC with integrated SIMATIC S7-1500 CPU for automation. SIPLUS extreme products are designed for reliable operation under extreme conditions, based on SIMATIC, LOGO!, SITOP, SINAMICS, SIMOTION, SCALANCE or other devices. SIPLUS devices use the same firmware as the products on which they are based", "sources": [ { "db": "NVD", "id": "CVE-2022-30694" }, { "db": "JVNDB", "id": "JVNDB-2022-020602" }, { "db": "CNVD", "id": "CNVD-2022-75547" }, { "db": "VULHUB", "id": "VHN-422285" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-30694", "trust": 3.9 }, { "db": "SIEMENS", "id": "SSA-478960", "trust": 3.1 }, { "db": "ICS CERT", "id": "ICSA-22-314-02", "trust": 0.8 }, { "db": "JVN", "id": "JVNVU93762879", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2022-020602", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2022-75547", "trust": 0.7 }, { "db": "CNNVD", "id": "CNNVD-202211-2266", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-422285", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-75547" }, { "db": "VULHUB", "id": "VHN-422285" }, { "db": "JVNDB", "id": "JVNDB-2022-020602" }, { "db": "CNNVD", "id": "CNNVD-202211-2266" }, { "db": "NVD", "id": "CVE-2022-30694" } ] }, "id": "VAR-202211-0343", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2022-75547" }, { "db": "VULHUB", "id": "VHN-422285" } ], "trust": 1.473885189354839 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-75547" } ] }, "last_update_date": "2024-08-14T12:44:38.027000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Cross Site Request Forgery Vulnerability in Several Siemens Products", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/360331" }, { "title": "Siemens SIMATIC Drive Controller Fixes for cross-site request forgery vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=232927" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-75547" }, { "db": "CNNVD", "id": "CNNVD-202211-2266" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-352", "trust": 1.1 }, { "problemtype": "Cross-site request forgery (CWE-352) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "VULHUB", "id": "VHN-422285" }, { "db": "JVNDB", "id": "JVNDB-2022-020602" }, { "db": "NVD", "id": "CVE-2022-30694" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478960.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu93762879/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-30694" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-314-02" }, { "trust": 0.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-478960.html" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/siemens-simatic-cross-site-request-forgery-via-login-page-39863" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-30694/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-75547" }, { "db": "VULHUB", "id": "VHN-422285" }, { "db": "JVNDB", "id": "JVNDB-2022-020602" }, { "db": "CNNVD", "id": "CNNVD-202211-2266" }, { "db": "NVD", "id": "CVE-2022-30694" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2022-75547" }, { "db": "VULHUB", "id": "VHN-422285" }, { "db": "JVNDB", "id": "JVNDB-2022-020602" }, { "db": "CNNVD", "id": "CNNVD-202211-2266" }, { "db": "NVD", "id": "CVE-2022-30694" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-11-09T00:00:00", "db": "CNVD", "id": "CNVD-2022-75547" }, { "date": "2022-11-08T00:00:00", "db": "VULHUB", "id": "VHN-422285" }, { "date": "2023-11-02T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-020602" }, { "date": "2022-11-08T00:00:00", "db": "CNNVD", "id": "CNNVD-202211-2266" }, { "date": "2022-11-08T11:15:10.413000", "db": "NVD", "id": "CVE-2022-30694" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-11-09T00:00:00", "db": "CNVD", "id": "CNVD-2022-75547" }, { "date": "2023-01-10T00:00:00", "db": "VULHUB", "id": "VHN-422285" }, { "date": "2023-11-02T08:05:00", "db": "JVNDB", "id": "JVNDB-2022-020602" }, { "date": "2023-04-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202211-2266" }, { "date": "2023-04-11T10:15:14.597000", "db": "NVD", "id": "CVE-2022-30694" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202211-2266" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cross-site request forgery vulnerability in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-020602" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "cross-site request forgery", "sources": [ { "db": "CNNVD", "id": "CNNVD-202211-2266" } ], "trust": 0.6 } }