All the vulnerabilites related to Siemens - SIMATIC MV550 S
var-202307-0656
Vulnerability from variot
A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3.4), SIMATIC MV540 S (All versions < V3.3.4), SIMATIC MV550 H (All versions < V3.3.4), SIMATIC MV550 S (All versions < V3.3.4), SIMATIC MV560 U (All versions < V3.3.4), SIMATIC MV560 X (All versions < V3.3.4). Affected devices cannot properly process specially crafted Ethernet frames sent to the devices. This could allow an unauthenticated remote attacker to cause a denial of service condition. The affected devices must be restarted manually. simatic mv540 h firmware, simatic mv540 s firmware, simatic mv550 h Multiple Siemens products such as firmware have unspecified vulnerabilities.Service operation interruption (DoS) It may be in a state. The SIMATIC MV500 products are fixed mount optical readers for capturing printed, laser, drilled, punched and dot-dash codes on a variety of different surfaces
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202307-0656", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic mv540 h", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.4" }, { "model": "simatic mv550 h", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.4" }, { "model": "simatic mv560 u", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.4" }, { "model": "simatic mv540 s", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.4" }, { "model": "simatic mv560 x", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.4" }, { "model": "simatic mv550 s", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.4" }, { "model": "simatic mv550 h", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic mv540 h", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic mv550 s", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic mv560 u", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic mv560 x", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic mv540 s", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic mv540 h", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v3.3.4" }, { "model": "simatic mv540 s", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v3.3.4" }, { "model": "simatic mv550 h", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v3.3.4" }, { "model": "simatic mv550 s", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v3.3.4" }, { "model": "simatic mv560 u", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v3.3.4" }, { "model": "simatic mv560", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x\u003cv3.3.4" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-56541" }, { "db": "JVNDB", "id": "JVNDB-2023-021765" }, { "db": "NVD", "id": "CVE-2023-35921" } ] }, "cve": "CVE-2023-35921", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2023-56541", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2023-35921", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2023-35921", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-35921", "trust": 1.0, "value": "HIGH" }, { "author": "productcert@siemens.com", "id": "CVE-2023-35921", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2023-35921", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2023-56541", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202307-744", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-56541" }, { "db": "JVNDB", "id": "JVNDB-2023-021765" }, { "db": "CNNVD", "id": "CNNVD-202307-744" }, { "db": "NVD", "id": "CVE-2023-35921" }, { "db": "NVD", "id": "CVE-2023-35921" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC MV540 H (All versions \u003c V3.3.4), SIMATIC MV540 S (All versions \u003c V3.3.4), SIMATIC MV550 H (All versions \u003c V3.3.4), SIMATIC MV550 S (All versions \u003c V3.3.4), SIMATIC MV560 U (All versions \u003c V3.3.4), SIMATIC MV560 X (All versions \u003c V3.3.4). Affected devices cannot properly process specially crafted Ethernet frames sent to the devices. This could allow an unauthenticated remote attacker to cause a denial of service condition. The affected devices must be restarted manually. simatic mv540 h firmware, simatic mv540 s firmware, simatic mv550 h Multiple Siemens products such as firmware have unspecified vulnerabilities.Service operation interruption (DoS) It may be in a state. The SIMATIC MV500 products are fixed mount optical readers for capturing printed, laser, drilled, punched and dot-dash codes on a variety of different surfaces", "sources": [ { "db": "NVD", "id": "CVE-2023-35921" }, { "db": "JVNDB", "id": "JVNDB-2023-021765" }, { "db": "CNVD", "id": "CNVD-2023-56541" }, { "db": "VULMON", "id": "CVE-2023-35921" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-35921", "trust": 3.9 }, { "db": "SIEMENS", "id": "SSA-561322", "trust": 3.1 }, { "db": "JVN", "id": "JVNVU95292697", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2023-021765", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-56541", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202307-744", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-35921", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-56541" }, { "db": "VULMON", "id": "CVE-2023-35921" }, { "db": "JVNDB", "id": "JVNDB-2023-021765" }, { "db": "CNNVD", "id": "CNNVD-202307-744" }, { "db": "NVD", "id": "CVE-2023-35921" } ] }, "id": "VAR-202307-0656", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-56541" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-56541" } ] }, "last_update_date": "2024-08-14T12:58:49.723000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens SIMATIC MV500 Devices Uncontrolled Resource Consumption Vulnerability (CNVD-2023-56541)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/443071" }, { "title": "Siemens SIMATIC Security vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=246825" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-56541" }, { "db": "CNNVD", "id": "CNNVD-202307-744" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-400", "trust": 1.0 }, { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021765" }, { "db": "NVD", "id": "CVE-2023-35921" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-561322.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu95292697/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-35921" }, { "trust": 0.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-561322.html" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-35921/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-56541" }, { "db": "VULMON", "id": "CVE-2023-35921" }, { "db": "JVNDB", "id": "JVNDB-2023-021765" }, { "db": "CNNVD", "id": "CNNVD-202307-744" }, { "db": "NVD", "id": "CVE-2023-35921" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-56541" }, { "db": "VULMON", "id": "CVE-2023-35921" }, { "db": "JVNDB", "id": "JVNDB-2023-021765" }, { "db": "CNNVD", "id": "CNNVD-202307-744" }, { "db": "NVD", "id": "CVE-2023-35921" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-07-17T00:00:00", "db": "CNVD", "id": "CNVD-2023-56541" }, { "date": "2023-07-11T00:00:00", "db": "VULMON", "id": "CVE-2023-35921" }, { "date": "2024-01-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-021765" }, { "date": "2023-07-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202307-744" }, { "date": "2023-07-11T10:15:10.610000", "db": "NVD", "id": "CVE-2023-35921" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-07-17T00:00:00", "db": "CNVD", "id": "CNVD-2023-56541" }, { "date": "2023-07-11T00:00:00", "db": "VULMON", "id": "CVE-2023-35921" }, { "date": "2024-01-19T08:08:00", "db": "JVNDB", "id": "JVNDB-2023-021765" }, { "date": "2023-07-20T00:00:00", "db": "CNNVD", "id": "CNNVD-202307-744" }, { "date": "2023-07-19T15:21:30.293000", "db": "NVD", "id": "CVE-2023-35921" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-744" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Vulnerabilities in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021765" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-744" } ], "trust": 0.6 } }
var-202307-0655
Vulnerability from variot
A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3.4), SIMATIC MV540 S (All versions < V3.3.4), SIMATIC MV550 H (All versions < V3.3.4), SIMATIC MV550 S (All versions < V3.3.4), SIMATIC MV560 U (All versions < V3.3.4), SIMATIC MV560 X (All versions < V3.3.4). The result synchronization server of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of all socket-based communication of the affected products if the result server is enabled. simatic mv540 h firmware, simatic mv540 s firmware, simatic mv550 h Multiple Siemens products, including firmware, contain vulnerabilities related to limited or unthrottled resource allocation.Service operation interruption (DoS) It may be in a state. The SIMATIC MV500 products are fixed mount optical readers for capturing printed, laser, drilled, punched and dot-dash codes on a variety of different surfaces
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202307-0655", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic mv540 h", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.4" }, { "model": "simatic mv550 h", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.4" }, { "model": "simatic mv560 u", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.4" }, { "model": "simatic mv540 s", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.4" }, { "model": "simatic mv560 x", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.4" }, { "model": "simatic mv550 s", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.4" }, { "model": "simatic mv550 h", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic mv540 h", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic mv550 s", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic mv560 u", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic mv560 x", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic mv540 s", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic mv540 h", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v3.3.4" }, { "model": "simatic mv540 s", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v3.3.4" }, { "model": "simatic mv550 h", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v3.3.4" }, { "model": "simatic mv550 s", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v3.3.4" }, { "model": "simatic mv560 u", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v3.3.4" }, { "model": "simatic mv560", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x\u003cv3.3.4" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-56540" }, { "db": "JVNDB", "id": "JVNDB-2023-021743" }, { "db": "NVD", "id": "CVE-2023-36521" } ] }, "cve": "CVE-2023-36521", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2023-56540", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2023-36521", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "productcert@siemens.com", "availabilityImpact": "HIGH", "baseScore": 8.6, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2023-36521", "impactScore": 4.0, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2023-36521", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-36521", "trust": 1.0, "value": "HIGH" }, { "author": "productcert@siemens.com", "id": "CVE-2023-36521", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2023-36521", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2023-56540", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202307-740", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-56540" }, { "db": "JVNDB", "id": "JVNDB-2023-021743" }, { "db": "CNNVD", "id": "CNNVD-202307-740" }, { "db": "NVD", "id": "CVE-2023-36521" }, { "db": "NVD", "id": "CVE-2023-36521" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC MV540 H (All versions \u003c V3.3.4), SIMATIC MV540 S (All versions \u003c V3.3.4), SIMATIC MV550 H (All versions \u003c V3.3.4), SIMATIC MV550 S (All versions \u003c V3.3.4), SIMATIC MV560 U (All versions \u003c V3.3.4), SIMATIC MV560 X (All versions \u003c V3.3.4). The result synchronization server of the affected products contains a\r\nvulnerability that may lead to a denial of service condition. An attacker may\r\ncause a denial of service situation of all socket-based communication of the\r\naffected products if the result server is enabled. simatic mv540 h firmware, simatic mv540 s firmware, simatic mv550 h Multiple Siemens products, including firmware, contain vulnerabilities related to limited or unthrottled resource allocation.Service operation interruption (DoS) It may be in a state. The SIMATIC MV500 products are fixed mount optical readers for capturing printed, laser, drilled, punched and dot-dash codes on a variety of different surfaces", "sources": [ { "db": "NVD", "id": "CVE-2023-36521" }, { "db": "JVNDB", "id": "JVNDB-2023-021743" }, { "db": "CNVD", "id": "CNVD-2023-56540" }, { "db": "VULMON", "id": "CVE-2023-36521" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-36521", "trust": 3.9 }, { "db": "SIEMENS", "id": "SSA-561322", "trust": 3.1 }, { "db": "JVN", "id": "JVNVU95292697", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2023-021743", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-56540", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202307-740", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-36521", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-56540" }, { "db": "VULMON", "id": "CVE-2023-36521" }, { "db": "JVNDB", "id": "JVNDB-2023-021743" }, { "db": "CNNVD", "id": "CNNVD-202307-740" }, { "db": "NVD", "id": "CVE-2023-36521" } ] }, "id": "VAR-202307-0655", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-56540" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-56540" } ] }, "last_update_date": "2024-08-14T12:47:30.923000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens SIMATIC MV500 Devices Uncontrolled Resource Consumption Vulnerability (CNVD-2023-56540)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/443066" }, { "title": "Siemens SIMATIC Security vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=246824" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-56540" }, { "db": "CNNVD", "id": "CNNVD-202307-740" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-770", "trust": 1.0 }, { "problemtype": "Allocation of resources without limits or throttling (CWE-770) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021743" }, { "db": "NVD", "id": "CVE-2023-36521" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-561322.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu95292697/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-36521" }, { "trust": 0.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-561322.html" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-36521/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-56540" }, { "db": "VULMON", "id": "CVE-2023-36521" }, { "db": "JVNDB", "id": "JVNDB-2023-021743" }, { "db": "CNNVD", "id": "CNNVD-202307-740" }, { "db": "NVD", "id": "CVE-2023-36521" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-56540" }, { "db": "VULMON", "id": "CVE-2023-36521" }, { "db": "JVNDB", "id": "JVNDB-2023-021743" }, { "db": "CNNVD", "id": "CNNVD-202307-740" }, { "db": "NVD", "id": "CVE-2023-36521" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-07-17T00:00:00", "db": "CNVD", "id": "CNVD-2023-56540" }, { "date": "2023-07-11T00:00:00", "db": "VULMON", "id": "CVE-2023-36521" }, { "date": "2024-01-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-021743" }, { "date": "2023-07-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202307-740" }, { "date": "2023-07-11T10:15:10.897000", "db": "NVD", "id": "CVE-2023-36521" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-07-17T00:00:00", "db": "CNVD", "id": "CNVD-2023-56540" }, { "date": "2023-07-11T00:00:00", "db": "VULMON", "id": "CVE-2023-36521" }, { "date": "2024-01-19T08:07:00", "db": "JVNDB", "id": "JVNDB-2023-021743" }, { "date": "2023-07-20T00:00:00", "db": "CNNVD", "id": "CNNVD-202307-740" }, { "date": "2023-07-19T15:21:04.790000", "db": "NVD", "id": "CVE-2023-36521" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-740" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Vulnerability in limiting or non-slotting resource allocation in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021743" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-740" } ], "trust": 0.6 } }
var-202307-0657
Vulnerability from variot
A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3.4), SIMATIC MV540 S (All versions < V3.3.4), SIMATIC MV550 H (All versions < V3.3.4), SIMATIC MV550 S (All versions < V3.3.4), SIMATIC MV560 U (All versions < V3.3.4), SIMATIC MV560 X (All versions < V3.3.4). Affected devices cannot properly process specially crafted IP packets sent to the devices. This could allow an unauthenticated remote attacker to cause a denial of service condition. The affected devices must be restarted manually. simatic mv540 h firmware, simatic mv540 s firmware, simatic mv550 h Multiple Siemens products such as firmware have unspecified vulnerabilities.Service operation interruption (DoS) It may be in a state. The SIMATIC MV500 products are fixed optical readers for capturing printed, laser, drilled, punched and dot-dash codes on a variety of different surfaces
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202307-0657", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic mv540 h", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.4" }, { "model": "simatic mv550 h", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.4" }, { "model": "simatic mv560 u", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.4" }, { "model": "simatic mv540 s", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.4" }, { "model": "simatic mv560 x", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.4" }, { "model": "simatic mv550 s", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.4" }, { "model": "simatic mv550 h", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic mv540 h", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic mv550 s", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic mv560 u", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic mv560 x", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic mv540 s", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic mv540 h", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v3.3.4" }, { "model": "simatic mv540 s", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v3.3.4" }, { "model": "simatic mv550 h", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v3.3.4" }, { "model": "simatic mv550 s", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v3.3.4" }, { "model": "simatic mv560 u", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v3.3.4" }, { "model": "simatic mv560", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x\u003cv3.3.4" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-56542" }, { "db": "JVNDB", "id": "JVNDB-2023-021766" }, { "db": "NVD", "id": "CVE-2023-35920" } ] }, "cve": "CVE-2023-35920", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2023-56542", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2023-35920", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2023-35920", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-35920", "trust": 1.0, "value": "HIGH" }, { "author": "productcert@siemens.com", "id": "CVE-2023-35920", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2023-35920", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2023-56542", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202307-745", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-56542" }, { "db": "JVNDB", "id": "JVNDB-2023-021766" }, { "db": "CNNVD", "id": "CNNVD-202307-745" }, { "db": "NVD", "id": "CVE-2023-35920" }, { "db": "NVD", "id": "CVE-2023-35920" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC MV540 H (All versions \u003c V3.3.4), SIMATIC MV540 S (All versions \u003c V3.3.4), SIMATIC MV550 H (All versions \u003c V3.3.4), SIMATIC MV550 S (All versions \u003c V3.3.4), SIMATIC MV560 U (All versions \u003c V3.3.4), SIMATIC MV560 X (All versions \u003c V3.3.4). Affected devices cannot properly process specially crafted IP packets sent to the devices. This could allow an unauthenticated remote attacker to cause a denial of service condition. The affected devices must be restarted manually. simatic mv540 h firmware, simatic mv540 s firmware, simatic mv550 h Multiple Siemens products such as firmware have unspecified vulnerabilities.Service operation interruption (DoS) It may be in a state. The SIMATIC MV500 products are fixed optical readers for capturing printed, laser, drilled, punched and dot-dash codes on a variety of different surfaces", "sources": [ { "db": "NVD", "id": "CVE-2023-35920" }, { "db": "JVNDB", "id": "JVNDB-2023-021766" }, { "db": "CNVD", "id": "CNVD-2023-56542" }, { "db": "VULMON", "id": "CVE-2023-35920" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-35920", "trust": 3.9 }, { "db": "SIEMENS", "id": "SSA-561322", "trust": 3.1 }, { "db": "JVN", "id": "JVNVU95292697", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2023-021766", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-56542", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202307-745", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-35920", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-56542" }, { "db": "VULMON", "id": "CVE-2023-35920" }, { "db": "JVNDB", "id": "JVNDB-2023-021766" }, { "db": "CNNVD", "id": "CNNVD-202307-745" }, { "db": "NVD", "id": "CVE-2023-35920" } ] }, "id": "VAR-202307-0657", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-56542" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-56542" } ] }, "last_update_date": "2024-08-14T12:34:37.215000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens SIMATIC MV500 Devices resource consumption out of control vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/443076" }, { "title": "Siemens SIMATIC Multiple products Security vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=246826" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-56542" }, { "db": "CNNVD", "id": "CNNVD-202307-745" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-400", "trust": 1.0 }, { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021766" }, { "db": "NVD", "id": "CVE-2023-35920" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-561322.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu95292697/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-35920" }, { "trust": 0.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-561322.html" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-35920/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-56542" }, { "db": "VULMON", "id": "CVE-2023-35920" }, { "db": "JVNDB", "id": "JVNDB-2023-021766" }, { "db": "CNNVD", "id": "CNNVD-202307-745" }, { "db": "NVD", "id": "CVE-2023-35920" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-56542" }, { "db": "VULMON", "id": "CVE-2023-35920" }, { "db": "JVNDB", "id": "JVNDB-2023-021766" }, { "db": "CNNVD", "id": "CNNVD-202307-745" }, { "db": "NVD", "id": "CVE-2023-35920" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-07-17T00:00:00", "db": "CNVD", "id": "CNVD-2023-56542" }, { "date": "2023-07-11T00:00:00", "db": "VULMON", "id": "CVE-2023-35920" }, { "date": "2024-01-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-021766" }, { "date": "2023-07-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202307-745" }, { "date": "2023-07-11T10:15:10.543000", "db": "NVD", "id": "CVE-2023-35920" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-07-17T00:00:00", "db": "CNVD", "id": "CNVD-2023-56542" }, { "date": "2023-07-11T00:00:00", "db": "VULMON", "id": "CVE-2023-35920" }, { "date": "2024-01-19T08:08:00", "db": "JVNDB", "id": "JVNDB-2023-021766" }, { "date": "2023-07-20T00:00:00", "db": "CNNVD", "id": "CNNVD-202307-745" }, { "date": "2023-07-19T14:58:06.770000", "db": "NVD", "id": "CVE-2023-35920" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-745" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Vulnerabilities in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021766" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-745" } ], "trust": 0.6 } }
cve-2022-33137
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf | x_refsource_MISC |
Vendor | Product | Version | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC MV540 H |
Version: All versions < V3.3 |
||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T08:01:19.904Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC MV540 H", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "product": "SIMATIC MV540 S", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "product": "SIMATIC MV550 H", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "product": "SIMATIC MV550 S", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "product": "SIMATIC MV560 U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "product": "SIMATIC MV560 X", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC MV540 H (All versions \u003c V3.3), SIMATIC MV540 S (All versions \u003c V3.3), SIMATIC MV550 H (All versions \u003c V3.3), SIMATIC MV550 S (All versions \u003c V3.3), SIMATIC MV560 U (All versions \u003c V3.3), SIMATIC MV560 X (All versions \u003c V3.3). The web session management of affected devices does not invalidate session ids in certain logout scenarios. This could allow an authenticated remote attacker to hijack other users\u0027 sessions." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-613", "description": "CWE-613: Insufficient Session Expiration", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-07-12T10:06:44", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-33137", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC MV540 H", "version": { "version_data": [ { "version_value": "All versions \u003c V3.3" } ] } }, { "product_name": "SIMATIC MV540 S", "version": { "version_data": [ { "version_value": "All versions \u003c V3.3" } ] } }, { "product_name": "SIMATIC MV550 H", "version": { "version_data": [ { "version_value": "All versions \u003c V3.3" } ] } }, { "product_name": "SIMATIC MV550 S", "version": { "version_data": [ { "version_value": "All versions \u003c V3.3" } ] } }, { "product_name": "SIMATIC MV560 U", "version": { "version_data": [ { "version_value": "All versions \u003c V3.3" } ] } }, { "product_name": "SIMATIC MV560 X", "version": { "version_data": [ { "version_value": "All versions \u003c V3.3" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC MV540 H (All versions \u003c V3.3), SIMATIC MV540 S (All versions \u003c V3.3), SIMATIC MV550 H (All versions \u003c V3.3), SIMATIC MV550 S (All versions \u003c V3.3), SIMATIC MV560 U (All versions \u003c V3.3), SIMATIC MV560 X (All versions \u003c V3.3). The web session management of affected devices does not invalidate session ids in certain logout scenarios. This could allow an authenticated remote attacker to hijack other users\u0027 sessions." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-613: Insufficient Session Expiration" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-33137", "datePublished": "2022-07-12T10:06:44", "dateReserved": "2022-06-13T00:00:00", "dateUpdated": "2024-08-03T08:01:19.904Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-35920
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC MV540 H |
Version: All versions < V3.3.4 |
||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T16:37:40.466Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-561322.pdf" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:siemens:simatic_mv540_h:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_mv540_h", "vendor": "siemens", "versions": [ { "lessThan": "V3.3.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_mv540_s:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_mv540_s", "vendor": "siemens", "versions": [ { "lessThan": "V3.3.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_mv550_h:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_mv550_h", "vendor": "siemens", "versions": [ { "lessThan": "V3.3.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_mv550_s:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_mv550_s", "vendor": "siemens", "versions": [ { "lessThan": "V3.3.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_mv560_u:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_mv560_u", "vendor": "siemens", "versions": [ { "lessThan": "V3.3.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_mv560_x:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_mv560_x", "vendor": "siemens", "versions": [ { "lessThan": "V3.3.4", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-35920", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-11-12T16:50:03.984084Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-12T16:53:53.862Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC MV540 H", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV540 S", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV550 H", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV550 S", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV560 U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV560 X", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.4" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC MV540 H (All versions \u003c V3.3.4), SIMATIC MV540 S (All versions \u003c V3.3.4), SIMATIC MV550 H (All versions \u003c V3.3.4), SIMATIC MV550 S (All versions \u003c V3.3.4), SIMATIC MV560 U (All versions \u003c V3.3.4), SIMATIC MV560 X (All versions \u003c V3.3.4). Affected devices cannot properly process specially crafted IP packets sent to the devices. This could allow an unauthenticated remote attacker to cause a denial of service condition. The affected devices must be restarted manually." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-07-11T09:07:08.275Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-561322.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-35920", "datePublished": "2023-07-11T09:07:08.275Z", "dateReserved": "2023-06-20T10:46:34.162Z", "dateUpdated": "2024-11-12T16:53:53.862Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-36521
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC MV540 H |
Version: All versions < V3.3.4 |
||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T16:52:52.404Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-561322.pdf" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:siemens:simatic_mv540_h:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_mv540_h", "vendor": "siemens", "versions": [ { "lessThan": "V3.3.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_mv540_s:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_mv540_s", "vendor": "siemens", "versions": [ { "lessThan": "V3.3.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_mv550_h:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_mv550_h", "vendor": "siemens", "versions": [ { "lessThan": "V3.3.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_mv550_s:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_mv550_s", "vendor": "siemens", "versions": [ { "lessThan": "V3.3.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_mv560_u:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_mv560_u", "vendor": "siemens", "versions": [ { "lessThan": "V3.3.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_mv560_x:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_mv560_x", "vendor": "siemens", "versions": [ { "lessThan": "V3.3.4", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-36521", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-11-21T14:06:23.456400Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-21T14:09:57.839Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC MV540 H", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV540 S", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV550 H", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV550 S", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV560 U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV560 X", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.4" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC MV540 H (All versions \u003c V3.3.4), SIMATIC MV540 S (All versions \u003c V3.3.4), SIMATIC MV550 H (All versions \u003c V3.3.4), SIMATIC MV550 S (All versions \u003c V3.3.4), SIMATIC MV560 U (All versions \u003c V3.3.4), SIMATIC MV560 X (All versions \u003c V3.3.4). The result synchronization server of the affected products contains a\r\nvulnerability that may lead to a denial of service condition. An attacker may\r\ncause a denial of service situation of all socket-based communication of the\r\naffected products if the result server is enabled." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.6, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-770", "description": "CWE-770: Allocation of Resources Without Limits or Throttling", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-07-11T09:07:13.637Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-561322.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-36521", "datePublished": "2023-07-11T09:07:13.637Z", "dateReserved": "2023-06-22T12:37:24.976Z", "dateUpdated": "2024-11-21T14:09:57.839Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-35921
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC MV540 H |
Version: All versions < V3.3.4 |
||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T16:37:40.422Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-561322.pdf" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:siemens:simatic_mv540_h:-:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "simatic_mv540_h", "vendor": "siemens", "versions": [ { "lessThan": "V3.3.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_mv540_s:-:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "simatic_mv540_s", "vendor": "siemens", "versions": [ { "lessThan": "V3.3.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_mv550_h:-:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "simatic_mv550_h", "vendor": "siemens", "versions": [ { "lessThan": "V3.3.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_mv550_s:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_mv550_s", "vendor": "siemens", "versions": [ { "lessThan": "V3.3.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_mv560_u:-:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "simatic_mv560_u", "vendor": "siemens", "versions": [ { "lessThan": "V3.3.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_mv560_x:-:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "simatic_mv560_x", "vendor": "siemens", "versions": [ { "lessThan": "V3.3.4", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-35921", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-11-13T14:25:45.446014Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-13T14:28:33.242Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC MV540 H", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV540 S", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV550 H", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV550 S", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV560 U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV560 X", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.4" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC MV540 H (All versions \u003c V3.3.4), SIMATIC MV540 S (All versions \u003c V3.3.4), SIMATIC MV550 H (All versions \u003c V3.3.4), SIMATIC MV550 S (All versions \u003c V3.3.4), SIMATIC MV560 U (All versions \u003c V3.3.4), SIMATIC MV560 X (All versions \u003c V3.3.4). Affected devices cannot properly process specially crafted Ethernet frames sent to the devices. This could allow an unauthenticated remote attacker to cause a denial of service condition. The affected devices must be restarted manually." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-07-11T09:07:09.314Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-561322.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-35921", "datePublished": "2023-07-11T09:07:09.314Z", "dateReserved": "2023-06-20T10:46:34.162Z", "dateUpdated": "2024-11-13T14:28:33.242Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-28400
Vulnerability from cvelistv5
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_b:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m812-1_adsl-router_annex_b", "vendor": "seimens", "versions": [ { "status": "affected", "version": "0" } ] }, { "cpes": [ "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_dk_standard_ethernet_controller:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "development_evaluation_kits_for_profinet_io_dk_standard_ethernet_controller", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_ek_ertec_200:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "development_evaluation_kits_for_profinet_io_ek_ertec_200", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_ek_ertec_200p:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "development_evaluation_kits_for_profinet_io_ek_ertec_200p", "vendor": "siemens", "versions": [ { "lessThan": "v4.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:ruggedcom_rm1224:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ruggedcom_rm1224", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:scalance_m804pb:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m804pb", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_a:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m812-1_adsl-router_annex_a", "vendor": "seimens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_b:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m812-1_adsl-router_annex_b", "vendor": "seimens", "versions": [ { "lessThan": "6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m816_1_adsl_router_annex_a:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m816_1_adsl_router_annex_a", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m816-1_adsl-router_annex_b:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m816-1_adsl-router_annex_b", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m826-2_shdsl-router:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m826-2_shdsl-router", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_m874_2:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_m874_2", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_m874_3:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_m874_3", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m876_3_evdo:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m876_3_evdo", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m876_3_rok:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m876_3_rok", "vendor": "siemens", "versions": [ { "lessThan": "6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m876_4_eu:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m876_4_eu", "vendor": "siemens", "versions": [ { "lessThan": "6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m876_4_nam:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m876_4_nam", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_s615", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w700_ieee_802.11n_family:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w700_ieee_802.11n_family", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1748_1_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1748_1_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1788_1_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1788_1_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1788_2_eec_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1788_2_eec_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1788_2_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1788_2_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1788_2ia_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1788_2ia_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_x200_4p_irt:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_x200_4p_irt", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_x201_3p_irt:0.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_x201_3p_irt", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_x201_3p_irt_pro:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_x201_3p_irt_pro", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalancce_x202_2p_irt:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalancce_x202_2p_irt", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_202_2p_irt_pro:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_202_2p_irt_pro", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalancce_x204_2:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalancce_x204_2", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_x204_2fm:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_x204_2fm", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_x204_2ld:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_x204_2ld", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_x204_2ld_ts:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_x204_2ld_ts", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_x204_2ts:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_x204_2ts", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2020-28400", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-06-13T18:59:11.953107Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-24T18:07:44.485Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-04T16:33:59.218Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7" } ] }, { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) EU", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) NAM", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M804PB", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M826-2 SHDSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-2", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-3", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-3 3G-Router (CN)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3 (ROK)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (NAM)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM853-1 (A1)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM853-1 (B1)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM853-1 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (A1)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (B1)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (CN)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (RoW)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615 EEC LAN-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615 LAN-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2 EEC M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2IA M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W721-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W721-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45 (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W738-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W738-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W761-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W761-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45 (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12 EEC (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2IA RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2IA RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X200-4P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2FM", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2LD", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2LD TS", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2TS", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X206-1", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X206-1LD", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X208", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X208PRO", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X212-2", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X212-2LD", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X216", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X224", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (230V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (24V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 230V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 24V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X304-2FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X306-1LD FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (230V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (24V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 230V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 24V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3LD", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3LD", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LD", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LD", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH+", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH+", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M TS", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M TS", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X320-1 FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X320-1-2LD FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X408-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3LD (SC, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3LD (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB208 (E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB208 (PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (SC, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (ST, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3LD (SC, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3LD (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB216 (E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB216 (PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2 (SC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2 (ST/BFOC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE EEC (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G (EIP DEF.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G (EIP def.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-3G PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-3G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204 DNA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA DNA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF206-1", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF208", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-8C", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-8C (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM416-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM416-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208 (Ethernet/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208PoE EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216 (Ethernet/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216POE EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M TS (24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M TS (24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (230V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324WG (24 x FE, AC 230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324WG (24 X FE, DC 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR326-2C PoE WG", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR326-2C PoE WG (without UL)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 1x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 24V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 2x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 1x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 24V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 2x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (2HR2)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CFU DIQ", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CFU PA", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CM 1542-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1604", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003e= V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1616", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003e= V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1626", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC IE/PB-LINK", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV540 H", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV540 S", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV550 H", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV550 S", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV560 U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV560 X", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET DK-16xx PN IO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003e= V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Power Line Booster PLB, Base Module", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PROFINET Driver", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V4.5" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC206-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC208", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SOFTNET-IE PNIO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-770", "description": "CWE-770: Allocation of Resources Without Limits or Throttling", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-10T13:53:22.763Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-28400", "datePublished": "2021-07-13T11:02:49", "dateReserved": "2020-11-10T00:00:00", "dateUpdated": "2024-12-10T13:53:22.763Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-33138
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf | x_refsource_MISC |
Vendor | Product | Version | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC MV540 H |
Version: All versions < V3.3 |
||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T08:01:19.531Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC MV540 H", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "product": "SIMATIC MV540 S", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "product": "SIMATIC MV550 H", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "product": "SIMATIC MV550 S", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "product": "SIMATIC MV560 U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "product": "SIMATIC MV560 X", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC MV540 H (All versions \u003c V3.3), SIMATIC MV540 S (All versions \u003c V3.3), SIMATIC MV550 H (All versions \u003c V3.3), SIMATIC MV550 S (All versions \u003c V3.3), SIMATIC MV560 U (All versions \u003c V3.3), SIMATIC MV560 X (All versions \u003c V3.3). Affected devices do not perform authentication for several web API endpoints. This could allow an unauthenticated remote attacker to read and download data from the device." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306: Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-07-12T10:06:46", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-33138", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC MV540 H", "version": { "version_data": [ { "version_value": "All versions \u003c V3.3" } ] } }, { "product_name": "SIMATIC MV540 S", "version": { "version_data": [ { "version_value": "All versions \u003c V3.3" } ] } }, { "product_name": "SIMATIC MV550 H", "version": { "version_data": [ { "version_value": "All versions \u003c V3.3" } ] } }, { "product_name": "SIMATIC MV550 S", "version": { "version_data": [ { "version_value": "All versions \u003c V3.3" } ] } }, { "product_name": "SIMATIC MV560 U", "version": { "version_data": [ { "version_value": "All versions \u003c V3.3" } ] } }, { "product_name": "SIMATIC MV560 X", "version": { "version_data": [ { "version_value": "All versions \u003c V3.3" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC MV540 H (All versions \u003c V3.3), SIMATIC MV540 S (All versions \u003c V3.3), SIMATIC MV550 H (All versions \u003c V3.3), SIMATIC MV550 S (All versions \u003c V3.3), SIMATIC MV560 U (All versions \u003c V3.3), SIMATIC MV560 X (All versions \u003c V3.3). Affected devices do not perform authentication for several web API endpoints. This could allow an unauthenticated remote attacker to read and download data from the device." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-306: Missing Authentication for Critical Function" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-33138", "datePublished": "2022-07-12T10:06:46", "dateReserved": "2022-06-13T00:00:00", "dateUpdated": "2024-08-03T08:01:19.531Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }