All the vulnerabilites related to Siemens - SIMATIC Information Server 2020
cve-2024-35783
Vulnerability from cvelistv5
Published
2024-09-10 09:36
Modified
2024-11-12 12:49
Summary
A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions), SIMATIC Information Server 2022 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions), SIMATIC Process Historian 2022 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges.
Impacted products
Vendor Product Version
Siemens SIMATIC Information Server 2020 Version: 0   < *
Siemens SIMATIC Information Server 2022 Version: 0   < *
Siemens SIMATIC PCS 7 V9.1 Version: 0   < V9.1 SP2 UC06
Siemens SIMATIC Process Historian 2020 Version: 0   < *
Siemens SIMATIC Process Historian 2022 Version: 0   < *
Siemens SIMATIC WinCC Runtime Professional V18 Version: 0   < V18 Update 5
Siemens SIMATIC WinCC Runtime Professional V19 Version: 0   < V19 Update 3
Siemens SIMATIC WinCC V7.4 Version: 0   < *
Siemens SIMATIC WinCC V7.5 Version: 0   < V7.5 SP2 Update 18
Siemens SIMATIC WinCC V8.0 Version: 0   < V8.0 Update 5
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:18:*:*:*:*:*:*:*",
              "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:19:*:*:*:*:*:*:*",
              "cpe:2.3:h:siemens:simatic_process_historian:2020:-:*:*:*:*:*:*",
              "cpe:2.3:a:siemens:simatic_process_historian:2022:*:*:*:*:*:*:*",
              "cpe:2.3:a:siemens:simatic_pcs7:*:*:*:*:*:*:*:*",
              "cpe:2.3:a:siemens:simatic_information_server:2020:-:*:*:*:*:*:*",
              "cpe:2.3:a:siemens:simatic_information_server:2022:*:*:*:*:*:*:*",
              "cpe:2.3:a:siemens:simatic_batch:9.1:-:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_batch",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_wincc",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "7.5_sp2_update_18",
                "status": "affected",
                "version": "7.4",
                "versionType": "custom"
              },
              {
                "lessThan": "8.0_update_5",
                "status": "affected",
                "version": "8.0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-35783",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-10T15:12:46.700884Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-10T17:31:08.389Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC BATCH V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Information Server 2020",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Information Server 2022",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.1 SP2 UC06",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Process Historian 2020",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Process Historian 2022",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Runtime Professional V18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V18 Update 5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Runtime Professional V19",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V19 Update 3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V7.4",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V7.5",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.5 SP2 Update 18",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V8.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0 Update 5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions), SIMATIC Information Server 2022 (All versions), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions), SIMATIC Process Historian 2022 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 9.4,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-250",
              "description": "CWE-250: Execution with Unnecessary Privileges",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-12T12:49:30.900Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-629254.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-35783",
    "datePublished": "2024-09-10T09:36:32.225Z",
    "dateReserved": "2024-05-17T11:07:53.264Z",
    "dateUpdated": "2024-11-12T12:49:30.900Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}